Prototype_Combo_Drawings.pdf
PDF 14 MB Posted
- Attached to
- IFB 160995 Bryant AHQ Combo & Fuel Facility
- Solicitation number
- IFB-129119
- Issued by
- Virginia
About this file
This document consists of prototype construction drawings and specifications for the Virginia Department of Transportation's Combo Building project, a standardized design intended for statewide site adaptation. The building is a single-story, approximately 4,980 gross square foot structure combining administrative office space (approximately 2,416 square feet) and vehicle maintenance facilities (approximately 2,582 square feet) with an occupant load of 61 persons. The prototype drawings, prepared by Virginia A&E, PLLC and dated April 11, 2025 (Revision 1 as of March 11, 2026), include comprehensive architectural, structural, mechanical, plumbing, and electrical design documentation consisting of 43 drawing sheets. The building is classified as mixed-use occupancy combining Group B (Business) and Group S-1 (Motor Vehicle Repair Garage) under the 2021 Virginia Construction Code, with a construction type of VB and a building height of 27 feet 7 inches from grade to average roof height. The design complies with applicable Virginia codes including the Virginia Uniform Statewide Building Code, Virginia Energy Conservation Code, and accessibility standards per the 2010 ADA Standards and ICC A117.1-2017.
The prototype design incorporates five selectable options allowing site-specific customization: Option 1 replaces shower facilities with closet storage; Option 2 substitutes casework for kitchen range equipment; Option 3 replaces an overhead coiling door with a window; Option 4 converts below-grade downspout collection to on-grade splash blocks; and Option 5 replaces work stations with vending machine space. The design accommodates flexible utility configurations supporting either 120V/208V three-phase or 120V/240V single-phase electrical service, propane or natural gas fuel systems, septic or public sewer sanitary service, and well or public water systems. Parking calculations require a minimum of 16 spaces plus one ADA van-accessible space and one electric vehicle charging station. The prototype assumes a minimum soil bearing capacity of 1,500 PSF, maximum wind speed of 130 MPH, seismic design category C, ground snow load of 70 PSF, and does not account for flood zones or coastal hazard areas; site-specific structural design modifications are required if actual conditions exceed these parameters. Energy efficiency improvements include more than 10 percent cooling efficiency gains for HVAC equipment and 10 percent reduction in lighting power density, with building thermal envelope certification and air barrier verification required per Virginia Energy Conservation Code Section C401.3 and C402.5.1.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VDOT
GENERAL INFORMATION:
FIRE SUPPRESSION SYSTEM:
WET
DRY
CHEMICAL
OTHER
NONE
NOT REQUIRED
ELEVATORS:
NEW
EXISTING
OTHER CONVEYORS: FIRE ALARM SYSTEM:
AUTOMATIC
MANUAL
NONE
NOT REQUIRED
(0) (0)
NEW
EXISTING
(0) (0)
OTHER:
1. NUMBER OF EXITS REQUIRED: 4 (VCC TABLE 1006.3.3)
NUMBER OF EXITS PROVIDED: 5
2. EXIT ACCESS TRAVEL DISTANCE ALLOWED: 200' (TABLE 1017.2) MAXIMUM
EXIT ACCESS TRAVEL MAXIMUM: 52'±
3. VECC C401.2 COMPLIANCE: IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE
BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405 AND
C408. SECTION C406 ADDITIONAL ENERGY EFFICIENCY CREDITS WILL BE VIA:
i. C406.2 - MORE EFFICIENT HVAC EQUIPMENT PERFORMANCE USING
C406.2.5 - MORE THAN TEN (10) PERCENT COOLING EFFICIENCY
IMPROVEMENT (FOR OFFICE AREA ONLY).
ii. C406.3 - REDUCED LIGHTING POWER DENSITY USING C406.3.1 - REDUCE
LIGHTING POWER BY MORE THAN TEN (10) PERCENT.
4. NO HAZARDOUS MATERIALS AS DEFINED IN VCC TABLES 307.1(1) & 307.1(2) WILL BE STORED WITHIN THE BUILDING.
5. PLUMBING FIXTURE CALCULATIONS AND BUILDING ENVELOPE AND INSULATION CALCULATIONS ARE LOCATED AS APPENDIX
TO THE PROJECT MANUAL .
6. IN ACCORD WITH THE HIGH PERFORMANCE BUILDING ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE NEW
BUILDING CONSTRUCTION IS NOT GREATER THAT 5,000 GROSS SQUARE FEET.
7. BABY CHANGING STATEMENT: BUILDING PROGRAM REQUIRES SECURITY MEASURES TO CONTROL ENTRANCE AND/OR EXIT, AND DOES NOT PERMIT CHILDREN UNDER THE AGE OF 30 MONTHS AS VISITORS.
PROJECT INFORMATION:
AGENCY: VIRGINIA DEPARTMENT OF TRANSPORTATION
PROJECT TITLE: PROTOTYPE COMBO BUILDING - 20 OR LESS AHQ STAFF FOR STATEWIDE SITE ADAPTATION
PROJECT CODE: 501-B4501-013
BUILDING INFORMATION:
BUILDING NAME/NUMBER: COMBO BUILDING
WORK PERMITTED: CONSTRUCTION OF A NEW BUILDING
PURPOSE/OCCUPANCY: OFFICE AND VEHICLE MAINTENANCE FACILITY
USE GROUP CLASSIFICATION: (B) BUSINESS (PER VCC SECTION 304) AND (S-1) MOTOR VEHICLE REPAIR GARAGE
(PER VCC SECTION 311.2); NON-SEPARATED MIXED USE (PER VCC SECTION 508.3)
TYPE OF CONSTRUCTION: VB
OCCUPANT LOAD OF BUILDING: 61 OCCUPANTS (PER VCC SECTION 1004) AND OCCUPANT LOAD TABLE ON DRAWING FP1
BUILDING HEIGHT (FEET): 27'-7" FROM GRADE PLANE TO THE AVERAGE HEIGHT OF THE HIGHEST ROOF SURFACE
(40 FEET ALLOWED PER VCC TABLE 504.3)
NUMBER OF STORIES: 1 (1 ALLOWED PER VCC TABLE 504.4)
GROSS AREA PER CPSM (GSF): 4,980 GROSS SQUARE FEET
BUILDING AREA PER VCC (SF): 4,462 SQUARE FEET (PER VCC CHAPTER 2; 9,000 SF ALLOWED BY VCC TABLE 506.2)
BUILDING VOLUME: 107,324± CUBIC FEET
CODE MODIFICATIONS ISSUED: N/A
APPLICABLE CODES & STANDARDS:
BUILDING CODES: 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE - VUSBC (EFFECTIVE JANUARY 18, 2024)
VIRGINIA CONSTRUCTION CODE - VCC (2021)
VIRGINIA MECHANICAL CODE - VMC (2021)
VIRGINIA PLUMBING CODE - VPC (2021)
VIRGINIA STATEWIDE FIRE PREVENTION CODE - VSFPC (2021)
VIRGINIA FUEL GAS CODE - VFGC (2021)
VIRGINIA ENERGY CONSERVATION CODE - VECC (2021)
VIRGINIA BUILDING AND FIRE CODE RELATED REGULATIONS - VBFCRR (2021)
NATIONAL ELECTRICAL CODE - NFPA-70 (2020)
STANDARD FOR INSTALLATION OF LIGHTNING PROTECTION SYSTEMS - NFPA-780 (2023)
ACCESSIBILITY STANDARDS: ADA90-TITLE II: CHAPTER 2 OF 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN DATED
SEPTEMBER 15, 2010 AND CHAPTERS 1 AND 3 THROUGH 11 OF STANDARD FOR ACCESSIBLE
AND USABLE BUILDINGS AND FACILITIES (ICC A117.1-2017) APPROVED MARCH 28, 2017.
OTHER STANDARDS: CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL - CPSM 2025 EDITION, REVISION 0 (MARCH 17, 2025); SITE ADAPTATION SHALL BE PREPARED WITH THE CURRENT CPSM VERSION
STRUCTURAL LOAD CRITERIA: REFER TO STRUCTURAL DRAWING S8
NONENONE
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTION
FOR CONSTRUCTION
APRIL 11, 2025
REV 1 MARCH 11, 2026
Drawing No.:
Project No.:
1"
Full Scale Verification
0"
T1
23125
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VA 24551
PHONE: (434) 316-6001
VAE PROJECT NO: 23125
DRAWING LIST:
DRAWING NO TITLE
T1 REV 1 2026-03-11 TITLE SHEET
FP1 FIRE PROTECTION INFORMATION PLAN
A1 LEGEND AND SCHEDULES
A2 REV 1 2026-03-11 FLOOR PLAN
A3 REV 1 2026-03-11 REFLECTED CEILING AND ROOF PLANS AND DETAILS
A4 REV 1 2026-03-11 ELEVATIONS
A5 REV 1 2026-03-11 BUILDING SECTIONS AND DETAILS
A6 REV 1 2026-03-11 WALL SECTIONS
A7 REV 1 2026-03-11 DETAILS AND SECTIONS
A8 REV 1 2026-03-11 WALL TYPES AND HEAD AND JAMB DETAILS
A9 DOOR, FRAME, AND WINDOW TYPES AND SECTIONS
A10 REV 1 2026-03-11 ENLARGED PLAN, ELEVATIONS, AND SECTIONS
A11 REV 1 2026-03-11 ELEVATIONS, SECTIONS, AND DETAILS
A12 OPTIONAL PLANS AND DETAILS
S1 FOUNDATION AND SLAB PLAN
S2 REV 1 2026-03-11 STEEL FRAMING PLAN
S3 ROOF FRAMING PLAN
S4 SECTIONS AND DETAILS
S5 SECTIONS AND DETAILS
S6 ROOF TRUSS PROFILES AND SECTIONS
S7 SECTIONS, DETAILS, AND OPTIONAL PLANS
S8 GENERAL NOTES
M1 LEGEND AND SPECIFICATIONS
M2 REV 1 2026-03-11 MECHANICAL PLAN
M3 SCHEDULES
M4 OPTIONAL PLAN AND SECTIONS
M5 DETAILS
M6 CONTROLS
P1 LEGEND, SPECIFICATIONS, AND DETAILS
P2 SANITARY PLAN AND OPTIONAL PLAN
P3 DOMESTIC WATER PLAN
P4 PLUMBING SCHEDULES
P5 PLUMBING RISER DIAGRAMS
E1 LEGEND, ABBREVIATIONS, AND GENERAL NOTES
E2 SINGLE LINE DIAGRAMS
E3 FLOOR PLAN - LIGHTING
E4 FLOOR PLAN - POWER
E5 ENLARGED PLAN AND OPTIONAL PLANS
E6 GROUNDING AND EMBED PLAN
E7 LIGHTNING PROTECTION SYSTEM
E8 DETAILS
E9 DETAILS
E10A SCHEDULES - 120/240V, SINGLE PHASE
E10B SCHEDULES - 208/120V, 3 PHASE
E11 SCHEDULES AND CALCULATIONS
E12 SCHEMATICS
E13 REV 1 2026-03-11 CONTROL SCHEMATICS
E14 LIGHTING CONTROL SCHEMATICS
GENERAL NOTES:
1. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED FOR USE AS
FABRICATION DRAWINGS. THESE DRAWINGS INDICATE THE GENERAL AND APPROXIMATE
SIZE AND LOCATION OF MATERIAL. FIELD VERIFY ALL DIMENSIONS AND LOCATIONS
PRIOR TO BEGINNING WORK. ALL UTILITIES NOTED ON PLANS ARE APPROXIMATE AND
CONTRACTOR SHALL FIELD VERIFY LOCATION.
2. ALL WORK SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS, INCLUDING, BUT NOT LIMITED TO, APPLICABLE CODES AND STANDARDS
LISTED ON THIS DRAWING.
3. ALL MATERIAL SHALL BE NEW UNLESS OTHERWISE NOTED. NO ASBESTOS CONTAINING
MATERIALS SHALL BE USED. MATERIALS ARE BASED ON THE INDICATED
MANUFACTURERS/MODELS AND ARE INTENDED ONLY TO SHOW THE GENERAL SIZE,
CONFIGURATION, LOCATION, CONNECTIONS, AND SUPPORT FOR INDICATED MATERIAL
WITH RELATION TO OTHER BUILDING SYSTEMS. MATERIAL BY ANY MANUFACTURER THAT
MEETS THE SCHEDULED CRITERIA IS ACCEPTABLE. CONTRACTOR SHALL BE
RESPONSIBLE FOR COORDINATING ACTUAL INSTALLED MATERIAL AND ASSOCIATED
CHANGES.
4. CONTRACTOR SHALL COORDINATE THE WORK WITH EXISTING CONDITIONS, INCLUDING
SITE FEATURES AND OTHER OBSTRUCTIONS, WHETHER OR NOT SUCH IS SHOWN ON
DRAWINGS.
5. CONTACT VIRGINIA 811 AT 1-800-552-7001, OR HTTPS://WWW.VA811.COM NO LESS THAN
72 HOURS PRIOR TO EXCAVATION AND DO NOT DISTURB THE SOIL UNTIL DIG TICKET HAS
BEEN PROCESSED.
6. CONTRACTOR SHALL COORDINATE THE WORK BETWEEN ALL TRADES. MATERIAL
LOCATIONS SHALL BE COORDINATED BETWEEN CIVIL, ARCHITECTURAL, STRUCTURAL,
MECHANICAL, PLUMBING, ELECTRICAL, AND DEMOLITION PLANS TO AVOID CONFLICTS.
7. ALL MATERIAL SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S WRITTEN
INSTALLATION INSTRUCTIONS, MAINTAINING ALL REQUIRED CLEARANCES AND WITH ALL
COMPONENTS ACCESSIBLE AND SERVICEABLE.
8. PROVIDE THERMAL ENVELOPE CERTIFICATION IN ACCORDANCE WITH 2021 VIRGINIA
ENERGY CONSERVATION CODE SECTION C401.3. FOLLOWING REVIEW AND APPROVAL OF
BY THE ARCHITECT/ENGINEER, POST A PERMANENT THERMAL CERTIFICATE IN UTILITY
105. CERTIFICATE SHALL INCLUDE:
a. R-VALUES OF INSULATION INSTALLED IN OR ON CEILINGS, ROOFS, WALLS, FOUNDATIONS, AND DUCTS OUTSIDE CONDITIONED SPACES,
b. U-FACTORS AND SOLAR HEAT GAIN COEFFICIENTS (SHGC) OF FENESTRATIONS, AND
c. RESULTS FROM BUILDING ENVELOPE AIR LEAKAGE TESTING PERFORMED ON THE
BUILDING.
WHERE THERE IS MORE THAN ONE VALUE OF ANY COMPONENT OF THE BUILDING
ENVELOPE, THE CERTIFICATE SHALL INDICATE THE AREA-WEIGHTED AVERAGE VALUE
WHERE AVAILABLE. IF THE AREA-WEIGHTED AVERAGE IS NOT AVAILABLE, THE
CERTIFICATE SHALL LIST EACH VALUE THAT APPLIES TO 10 PERCENT OR MORE OF THE
TOTAL COMPONENT AREA.
9. SITE ADAPTATION REGISTERED DESIGN PROFESSIONAL SHALL PROVIDE VERIFICATION
OF BUILDING ENVELOPE PERFORMANCE PER VIRGINIA ENERGY CONSERVATION CODE
SECTION C402.5.1.5. THE INSTALLATION OF THE CONTINUOUS AIR BARRIER SHALL BE
VERIFIED IN ACCORDANCE WITH THE FOLLOWING:
A. REVIEW OF THE CONSTRUCTION DOCUMENTS AND OTHER SUPPORTING DATA
SHALL BE CONDUCTED TO ASSESS COMPLIANCE WITH THE REQUIREMENTS
IN VIRGINIA ENERGY CONSERVATION CODE SECTION C402.5.1.
B. INSPECTION OF CONTINUOUS AIR BARRIER COMPONENTS AND ASSEMBLIES SHALL
BE CONDUCTED DURING CONSTRUCTION WHILE THE AIR BARRIER IS STILL
ACCESSIBLE FOR INSPECTION AND REPAIR TO VERIFY COMPLIANCE WITH THE
REQUIREMENTS OF VIRGINIA ENERGY CONSERVATION CODE SECTIONS
C402.5.1.3 AND C402.5.1.4.
C. A FINAL REPORT SHALL BE PROVIDED FOR INSPECTIONS COMPLETED. THE REPORT
SHALL BE PROVIDED TO THE BUILDING OWNER, OWNER'S AUTHORIZED AGENT AND
THE CODE OFFICIAL. THE REPORT SHALL IDENTIFY DEFICIENCIES FOUND DURING
THE REVIEW OF THE CONSTRUCTION DOCUMENTS AND INSPECTION AND DETAILS
OF CORRECTIVE MEASURES TAKEN.
10. BUILDING THERMAL ENVELOPE SHALL BE TESTED PER VIRGINIA ENERGY CONSERVATION
CODE SECTION C402.5.3. REFER TO SPECIFICATION 019119.43 - EXTERIOR ENCLOSURE
TESTING.
11. DEFINITIONS:
· FURNISH: SUPPLY AND DELIVER TO PROJECT SITE FOR INSTALLATION BY OTHERS.
· INSTALL: INSTALL ITEMS FURNISHED BY OTHERS, INCLUDING UNLOADING,
TEMPORARILY STORING, UNPACKING, AND ASSEMBLY.
· PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE.
· REMOVE: DETACH ITEMS FROM EXISTING CONSTRUCTION AND LEGALLY DISPOSE OF
THEM OFF-SITE UNLESS INDICATED TO BE REMOVED AND SALVAGED OR REMOVED
AND REINSTALLED.
· REMOVE AND REINSTALL: DETACH ITEMS FROM EXISTING CONSTRUCTION, PREPARE
FOR REUSE, AND REINSTALL WHERE INDICATED.
· REMOVE AND SALVAGE: CAREFULLY DETACH FROM EXISTING CONSTRUCTION, IN A
MANNER TO PREVENT DAMAGE, AND DELIVER TO OWNER.
PROTOTYPE SITE ADAPTATION NOTES:
1. THE PROTOTYPE DRAWINGS AND TECHNICAL SPECIFICATIONS PROVIDE BASE PLANS,
ELEVATIONS, SECTIONS, DETAILS, SCHEMATICS, SCHEDULES, AND MATERIAL
SPECIFICATIONS FOR THE BUILDING CONSTRUCTION ALONG WITH ASSOCIATED UTILITY
ENTRANCE LOCATIONS. THE SITE ADAPTATION DESIGN SHALL PROVIDE DRAWINGS AND
SPECIFICATIONS FOR SITE SPECIFIC INTEGRATION AND CONSTRUCTION INCLUDING, BUT
NOT LIMITED TO, GENERAL CONDITIONS, GEOTECHNICAL INFORMATION, BUILDING
ORIENTATION, FENCING, PARKING, SITE LIGHTING, STORMWATER MANAGEMENT,
DOWNSPOUT COLLECTION, OTHER STRUCTURES, OTHER SITE IMPROVEMENTS, AND
UTILITIES INCLUDING, BUT NOT LIMITED TO, WATER, SANITARY, POWER, EMERGENCY
POWER, COMMUNICATIONS, AND FUEL MANAGEMENT SYSTEM.
2. PROTOTYPE DRAWINGS AND TECHNICAL SPECIFICATIONS INCLUDE THE OPTIONS
INDICATED BELOW. OPTIONS SHALL BE INCORPORATED AS INDICATED ON THE SITE
ADAPTATION PROJECT COVER SHEET:
OPTION 1: RESTROOMS - REPLACE SHOWERS WITH CLOSET
BASE PLANS INCLUDE A SHOWER IN BOTH THE MEN'S AND WOMEN'S RESTROOMS.
OPTION 1 REPLACES THE SHOWERS WITH A SINGLE CLOSET ACCESSED FROM THE
CORRIDOR.
OPTION 2: KITCHEN - REPLACE RANGE AND RANGE HOOD WITH CASEWORK
BASE PLANS INCLUDE AN ELECTRIC RANGE AND RANGE HOOD IN THE STAFF WORK
ROOM KITCHENETTE. OPTION 2 REPLACES THE RANGE AND RANGE HOOD WITH
CASEWORK.
OPTION 3: MAINTENANCE BAY - REPLACE OVERHEAD COILING DOOR WITH WINDOW
BASE PLANS INCLUDE AN OVERHEAD COILING DOOR ON THE REAR OF THE
MAINTENANCE BAYS FOR DRIVE-THROUGH CAPABILITY IN THE END BAY. OPTION 3
REPLACES THE OVERHEAD COILING DOOR ON THE REAR OF THE BUILDING WITH A
WINDOW SIMILAR TO AN EXISTING ADJACENT WINDOW.
OPTION 4: DOWNSPOUTS - REPLACE BELOW GRADE DOWNSPOUT COLLECTION WITH
SPLASH BLOCKS ON GRADE
BASE PLANS INCLUDE DOWNSPOUTS CONNECTED TO A BELOW GRADE COLLECTION
SYSTEM DESIGNED BY SITE ADAPTATION DESIGN. OPTION 4 REPLACES THE
DOWNSPOUT COLLECTION WITH SPLASH BLOCKS ON GRADE.
OPTION 5: STAFF WORK ROOM - REPLACE WORK STATIONS WITH VENDING
BASE PLANS INCLUDE FOUR BUILT-IN WORK STATIONS. OPTION 5 REPLACES TWO
BUILT-IN WORK STATIONS WITH A VENDING MACHINE AREA.
3. PROTOTYPE DRAWINGS AND TECHNICAL SPECIFICATIONS INCLUDE PROVISIONS FOR
VARYING UTILITY TYPES. PROTOTYPE MECHANICAL SCHEDULES FOR DUAL FUEL
PACKAGED UNIT AND VEHICLE EXHAUST EXTRACTION FAN INCLUDE OPTIONS FOR
120V/208V POWER AND 120V/240V POWER. PROTOTYPE MECHANICAL AND PLUMBING
SCHEDULES AND TECHNICAL SPECIFICATIONS FOR DUAL FUEL PACKAGED UNIT,
GAS-FIRED INFRARED HEATER, AND TANKLESS GAS-FIRED DOMESTIC WATER HEATER
INCLUDE OPTIONS FOR BOTH PROPANE AND NATURAL GAS. PROTOTYPE PLUMBING
PLANS ARE APPLICABLE TO EITHER A SEPTIC SYSTEM OR PUBLIC SEWER SYSTEM AS
WELL AS WELL WATER OR A PUBLIC WATER SYSTEM. UTILITY TYPES TO BE INDICATED
ON THE SITE ADAPTATION PROJECT COVER SHEET FOLLOW:
a. ELECTRIC SERVICE - THREE PHASE (208/120 - 3P/4W) OR SINGLE PHASE (120/240 -
1P/3W)
b. GAS SERVICE - PROPANE OR NATURAL GAS
c. SANITARY SERVICE - SEPTIC SYSTEM OR PUBLIC SEWER SYSTEM
d. WATER SERVICE - WELL WATER OR PUBLIC WATER SYSTEM
4. PROTOTYPE DRAWINGS INCLUDING PROVISIONS FOR POWER FOR THE FOLLOWING
EQUIPMENT IF REQUIRED FOR SITE ADAPTATION. ITEMS WITH A * ARE ALLOCATED
SPACE IN THE UTILITY ROOM OR ELSEWHERE ON PLANS. THE FOLLOWING ITEMS ARE
ONLY INCORPORATED IF SPECIFIED AS PART OF THE SITE ADAPTATION DESIGN.
a. WELL PUMP
b. WATER PRESSURE TANK*
c. WATER TREATMENT SYSTEM*
d. SEPTIC SYSTEM LIFT PUMP
e. TMS FUEL MANAGEMENT SYSTEM
5. PROTOTYPE DRAWINGS RESERVE SPACE ON THE PLANS FOR THE FOLLOWING
EQUIPMENT. THE FOLLOWING ITEMS ARE ONLY INCORPORATED IF SPECIFIED AS PART
OF THE SITE ADAPTATION DESIGN.
a. GENERATOR REMOTE ANNUNCIATOR
b. ATS MONITOR
c. BACKFLOW PREVENTER AND PIPING TO FEED SITE FROM UTILITY ROOM
6. PROTOTYPE HVAC EQUIPMENT AND AIRFLOWS ARE BASED ON LOAD MODELING AT
VARIOUS LOCATIONS AND BUILDING ORIENTATIONS, WITH WORST-CASE OUTDOOR
DESIGN TEMPERATURES OF 95°F DB / 76°F WB SUMMER AND 12°F WINTER. TWO
PACKAGED UNIT SIZES (4-TON AND 5-TON) ARE SCHEDULED TO COVER ANY LOCATION
AND ORIENTATION IN VIRGINIA. DUCTWORK IS SIZED FOR THE SUM OF THE WORST CASE
AIRFLOWS AT EACH ROOM IN ORDER TO ACCOMMODATE ALL SITES WITHOUT DUCT
MODIFICATIONS. AS PART OF EACH SITE ADAPTATION DESIGN PREPARED BY OTHERS,
VIRGINIA A&E WILL UPDATE THE HVAC LOAD MODEL TO REFLECT ACTUAL LOCATION AND
BUILDING ORIENTATION, AND PROVIDE THE PACKAGED UNIT SIZE AND REVISED
AIRFLOW RATE SCHEDULE (DRAWING M3).
7. DESIGN SOIL BEARING CAPACITY: THIS DESIGN ASSUMES A MINIMUM SOIL BEARING
CAPACITY OF 1,500 PSF. IF SITE GEOTECHNICAL INVESTIGATION INDICATES A BEARING
CAPACITY LESS THAN 1,500 PSF, A FOUNDATION DESIGN SHALL BE PREPARED BY
OTHERS FOR SITE SPECIFIC CONDITIONS.
8. MAXIMUM BASIC WIND SPEED IS 130 MPH. IF SITE BASIC WIND SPEED IS GREATER THAN
130 MPH, OR IS LOCATED IN A SPECIAL WIND REGION AS DEFINED IN ASCE 7-22 FIGURE
26.5-1B, A STRUCTURAL DESIGN SHALL BE PREPARED BY OTHERS FOR SITE SPECIFIC
CONDITIONS. REFER TO VCC 1609.3 FOR ADDITIONAL INFORMATION ON SPECIAL WIND
REGIONS, NEAR MOUNTAINOUS TERRAIN AND NEAR GORGES.
9. MAXIMUM SEISMIC DESIGN CATEGORY IS C. IF SITE SEISMIC DESIGN CATEGORY IS D, E, OR F, A STRUCTURAL DESIGN SHALL BE PREPARED BY OTHERS FOR SITE SPECIFIC
CONDITIONS.
10. IF THE SITE IS LOCATED WITHIN 1 MILE OF THE COASTAL MEAN HIGH WATER LINE,
WHERE THE BASIC WIND SPEED IS EQUAL TO OR GREATER THAN 130 MPH, OR IN AREAS
WHERE THE BASIC WIND SPEED IS EQUAL TO OR GREATER THAN 140 MPH, THE
PROVISIONS OF ASCE 7-22 26.12 SHALL BE INCORPORATED INTO SPECIFICATION
SECTION 088000 - GLAZING BY OTHERS FOR SITE SPECIFIC CONDITIONS.
11. IF THE SITE IS LOCATED WITHIN A FLOOD ZONE, A STRUCTURAL DESIGN SHALL BE
PREPARED BY OTHERS FOR SITE SPECIFIC CONDITIONS.
12. MAXIMUM GROUND SNOW LOAD IS 70 PSF. IF THE SITE IS LOCATED WITH GROUND SNOW
LOAD GREATER THAN 70 PSF, A STRUCTURAL DESIGN SHALL BE PREPARED BY OTHERS
FOR SITE SPECIFIC CONDITIONS.
DELEGATED DESIGN SYSTEMS AND PRODUCTS:
1. WOOD ROOF TRUSSES ARE INCLUDED IN THIS PROJECT AS A DELEGATED
DESIGN SYSTEM AND SHALL COMPLY WITH THE LOAD CRITERIA INDICATED
ON DRAWING S8 AND SPECIFICATION SECTION 061753 – SHOP-FABRICATED
WOOD TRUSSES.
2. COMPUTER-BASED, ELECTRICAL COORDINATION ANALYSIS FOR THE COMBO
BUILDING IS DELEGATED DESIGN AND SHALL COMPLY WITH SPECIFICATION
SECTION 260573 - ELECTRICAL COORDINATION ANALYSIS.
COMBO BUILDING
SCOTT F. BURGER
Lic. No. 034338
STEPHEN D. HERRING
Lic. No. 015253 Lic. No. 058604
JOSHUA S. KNIGHT
Lic. No. 035249
STEVEN M. HOVIS
PROTOTYPE COMBO BUILDING - 20 OR LESS AHQ STAFF
MINIMUM PARKING CALCULATIONS
BUILDING / STRUCTURE USE GROUP CPSM 6.2.7.3
PARKING CRITERIA
BUILDING
AREA
(GSF)
# OF
EMPLOYEES
PARKING
SPACES
REQUIRED
COMBO BUILDING - OFFICE (B) - BUSINESS 1 PER 250 GSF 2,646 10 11
COMBO BUILDING - MAINTENANCE BAY (S-1) - STORAGE 1 PER 2 EMPLOYEES 2,334 10 5
TOTALS: 4,980 20 16
NOTES:
1. 16 PARKING SPACES REQUIRED PER CPSM 6.2.7.3.
2. 1 ADA PARKING SPACES REQUIRED PER 2010 ASAD TABLE 208.2. THE ONE (1) ADA PARKING SPACE SHALL BE VAN ACCESSIBLE AND LOCATED ON AN ACCESSIBLE ROUTE AND LOCATED WITHIN 250' OF THE ACCESSIBLE
ENTRANCE TO THE BUILDING.
3. 1 ELECTRIC VEHICLE PARKING SPACE (EVPS) AND ELECTRIC VEHICLE CHARGING STATION (EVCS) REQUIRED
THROUGH 2032 PER CPSM APPENDIX G AND ASSOCIATED FIGURE G.4.1.2.
4. ABOVE PARKING IS THE MINIMUM PARKING SPACES REQUIRED BY THE REFERENCED STANDARDS FOR THE BUILDING. SITE ADAPTATION SHALL DETERMINE THE NUMBER OF EMPLOYEES NOTED ABOVE AND REQUIRED PARKING FOR EMPLOYEES, VISITORS, ADA, AND EVPS / EVCS FOR THE ENTIRE SITE.1
03/11/2026 03/11/2026 03/11/2026 03/11/2026
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
06/18/2026 501-B4501-013
4 4
FE
FE
44'
FE
FE
FE
SCALE:
0 1' 5' 10'
1/4"=1'-0"
FIRE PROTECTION INFORMATION PLAN
MAINTENANCE
BAYS
STAFF WORK
ROOM
UTILITY
OPEN
OFFICE
ENTRANCE
OFFICE
CORRIDOR
WOMEN'S
RESTROOM
MEN'S
RESTROOM
LOCKER
ROOM
JAN
CLOSET
C O
R R
ID
O
R
25 52'
GENERAL INFORMATION:
FIRE SUPPRESSION SYSTEM: ELEVATORS: OTHER CONVEYORS: FIRE ALARM SYSTEM:
PROJECT INFORMATION:
AGENCY: VIRGINIA DEPARTMENT OF TRANSPORTATION
PROJECT TITLE: PROTOTYPE COMBO BUILDING - 20 OR LESS AHQ STAFF FOR STATEWIDE SITE ADAPTATION
PROJECT CODE: 501-B4501-013
BUILDING INFORMATION:
BUILDING NAME/NUMBER: COMBO BUILDING
WORK PERMITTED: CONSTRUCTION OF A NEW BUILDING
PURPOSE/OCCUPANCY: OFFICE AND VEHICLE MAINTENANCE FACILITY
USE GROUP CLASSIFICATION: (B) BUSINESS (PER VCC SECTION 304) AND (S-1) MOTOR VEHICLE REPAIR GARAGE
(PER VCC SECTION 311.2); NON-SEPARATED MIXED USE (PER VCC SECTION 508.3)
TYPE OF CONSTRUCTION: VB
OCCUPANT LOAD OF BUILDING: 61 OCCUPANTS (PER VCC SECTION 1004) AND OCCUPANT LOAD TABLE ON DRAWING FP1
BUILDING HEIGHT (FEET): 27'-7" FROM GRADE PLANE TO THE AVERAGE HEIGHT OF THE HIGHEST ROOF SURFACE
(40 FEET ALLOWED PER VCC TABLE 504.3)
NUMBER OF STORIES: 1 (1 ALLOWED PER VCC TABLE 504.4)
GROSS AREA PER CPSM (GSF): 4,980 GROSS SQUARE FEET
BUILDING AREA PER VCC (SF): 4,462 SQUARE FEET (PER VCC CHAPTER 2; 9,000 SF ALLOWED BY VCC TABLE 506.2)
BUILDING VOLUME: 107,324± CUBIC FEET
CODE MODIFICATIONS ISSUED: N/A
APPLICABLE CODES & STANDARDS:
BUILDING CODES: 2021 VIRGINIA UNIFORM STATEWIDE BUILDING CODE - VUSBC (EFFECTIVE JANUARY 18, 2024)
VIRGINIA CONSTRUCTION CODE - VCC (2021)
VIRGINIA MECHANICAL CODE - VMC (2021)
VIRGINIA PLUMBING CODE - VPC (2021)
VIRGINIA STATEWIDE FIRE PREVENTION CODE - VSFPC (2021)
VIRGINIA FUEL GAS CODE - VFGC (2021)
VIRGINIA ENERGY CONSERVATION CODE - VECC (2021)
VIRGINIA BUILDING AND FIRE CODE RELATED REGULATIONS - VBFCRR (2021)
NATIONAL ELECTRICAL CODE - NFPA-70 (2020)
STANDARD FOR INSTALLATION OF LIGHTNING PROTECTION SYSTEMS - NFPA-780 (2023)
ACCESSIBILITY STANDARDS: ADA90-TITLE II: CHAPTER 2 OF 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN DATED
SEPTEMBER 15, 2010 AND CHAPTERS 1 AND 3 THROUGH 11 OF STANDARD FOR ACCESSIBLE
AND USABLE BUILDINGS AND FACILITIES (ICC A117.1-2017) APPROVED MARCH 28, 2017.
OTHER STANDARDS: CONSTRUCTION AND PROFESSIONAL SERVICES MANUAL - CPSM 2025 EDITION, REVISION 0 (MARCH 17, 2025); SITE ADAPTATION SHALL BE PREPARED WITH THE CURRENT CPSM VERSION
STRUCTURAL LOAD CRITERIA: REFER TO STRUCTURAL DRAWING S8
FIRE SUPPRESSION SYSTEM:
WET
DRY
CHEMICAL
OTHER
NONE
NOT REQUIRED
ELEVATORS:
NEW
EXISTING
OTHER CONVEYORS: FIRE ALARM SYSTEM:
AUTOMATIC
MANUAL
NONE
NOT REQUIRED
(0) (0)
NEW
EXISTING
(0) (0)
OTHER:
1. NUMBER OF EXITS REQUIRED: 4 (VCC TABLE 1006.3.3)
NUMBER OF EXITS PROVIDED: 5
2. EXIT ACCESS TRAVEL DISTANCE ALLOWED: 200' (TABLE 1017.2) MAXIMUM
EXIT ACCESS TRAVEL MAXIMUM: 52'±
3. VECC C401.2 COMPLIANCE: IN ACCORD WITH THE VIRGINIA ENERGY CONSERVATION CODE (VECC), THE
BUILDING SHALL COMPLY WITH VECC SECTIONS C402 THROUGH C405 AND
C408. SECTION C406 ADDITIONAL ENERGY EFFICIENCY CREDITS WILL BE VIA:
i. C406.2 - MORE EFFICIENT HVAC EQUIPMENT PERFORMANCE USING
C406.2.5 - MORE THAN TEN (10) PERCENT COOLING EFFICIENCY
IMPROVEMENT (FOR OFFICE AREA ONLY).
ii. C406.3 - REDUCED LIGHTING POWER DENSITY USING C406.3.1 - REDUCE
LIGHTING POWER BY MORE THAN TEN (10) PERCENT.
4. NO HAZARDOUS MATERIALS AS DEFINED IN VCC TABLES 307.1(1) & 307.1(2) WILL BE STORED WITHIN THE BUILDING.
5. PLUMBING FIXTURE CALCULATIONS AND BUILDING ENVELOPE AND INSULATION CALCULATIONS ARE LOCATED AS APPENDIX
TO THE PROJECT MANUAL .
6. IN ACCORD WITH THE HIGH PERFORMANCE BUILDING ACT, THE BUILDING IS EXEMPT FROM COMPLIANCE BECAUSE THE NEW
BUILDING CONSTRUCTION IS NOT GREATER THAT 5,000 GROSS SQUARE FEET.
7. BABY CHANGING STATEMENT: BUILDING PROGRAM REQUIRES SECURITY MEASURES TO CONTROL ENTRANCE AND/OR EXIT, AND DOES NOT PERMIT CHILDREN UNDER THE AGE OF 30 MONTHS AS VISITORS.
NONENONE
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
FIRE PROTECTION
INFORMATION PLAN
FP1
LEGEND:
ROOM NUMBER
XXXXXXXX
XXXXXX
ROOM NAME
MAXIMUM OCCUPANT LOAD OF EXIT
ROOM SIZE (SQUARE FEET)
SQUARE FEET PER PERSON
CALCULATED OCCUPANCY
OCCUPANCY LOAD
XXX
XXX
XXX
XXX
TRAVEL DISTANCE TO EXITXX'
FIRE EXTINGUISHER WITH RATINGFE 4-A:80-B:C PER VSFPC 3504.2.6
WALL MOUNTED EXIT SIGN
CEILING MOUNTED EXIT SIGN
GENERAL INFORMATION:
SCALE: NONE
OCCUPANCY DEFINITION PLAN
OCCUPANT LOAD TABLE
BUILDING AREA (SEE GENERAL INFORMATION) 4462
ROOM
NUMBER ROOM NAME SQUARE
FOOTAGE
FUNCTION OF
SPACE (TABLE
1004.5)
SF /
OCC.
OCCUPANT
COUNT
GROUP B OFFICE AREAS (VCC 304.1)
102 OFFICE 128 B 150 1
103 OPEN OFFICE 381 B 150 3
TOTAL GROUP B OFFICE AREAS 509 4
AREAS CLASSIFIED AS GROUP B (VCC CHAPTER 3)
105 UTILITY 142 B 300 1
106 STAFF WORK ROOM 580 A-3 15 39
108 LOCKER ROOM 194 B 50 4
TOTAL AREAS CLASSIFIED AS GROUP B 916 44
AREAS CLASSIFIED AS GROUP S-1 (VCC 311.2)
113 MAINTENANCE BAYS 2334 S-1 300 8
TOTAL AREAS GROUP B AND S-1 3759 56
NET GROUP B BUILDING AREA (4462-3759) 703 B 150 5
TOTAL BUILDING OCCUPANT LOAD --- --- 61
GENERAL NOTES:
1. BUILDING IS GROUP B PER VCC 304.1 AND S-1 PER VCC 311.2.
2. GROUP A-3 SPACES ARE CLASSIFIED AS GROUP B PER VCC 303.1.2 SMALL ASSEMBLY SPACES.
3. GROUPS S-1 ROOMS ARE MEASURED GROSS SF.
B (BUSINESS)
2,128 BUILDING
AREA)
(2,398 GSF;
STEPHEN D. HERRING
Lic. No. 015253
S-1 (MODERATE-
(2,582 GSF; 2,334
BUILDING AREA)
HAZARD STORAGE)
04/11/2025
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
LEGEND AND SCHEDULES
A1
LEGEND
MATERIAL
LOC
MATCHLINE
NORTH
A
AX AX
A
AX AX
A
AX AX
AX AX
LETTER INDICATES
DETAIL
DRAWING NUMBER WHERE
DETAIL IS DRAWN
DRAWING NUMBER WHERE
DETAIL IS TAKEN
LETTER INDICATES
ENLARGED PLAN
DRAWING NUMBER WHERE
ENLARGED PLAN IS DRAWN
DRAWING NUMBER WHERE
ENLARGED PLAN IS TAKEN
LETTER INDICATES
ELEVATION
DRAWING NUMBER WHERE
ELEVATION IS DRAWN
DRAWING NUMBER WHERE
ELEVATION IS TAKEN
NUMBER INDICATES
SECTION
DRAWING NUMBER WHERE
SECTION IS DRAWN
DRAWING NUMBER WHERE
SECTION IS TAKEN
REVISION TRIANGLE
REVISION CLOUD
X
X
X
F1 F1
F2 F2
F3 F3
F4 F4
WALKPADS, LIGHTWEIGHT
CONCRETE, GROUT
CAST-IN-PLACE CONCRETE
CONCRETE MASONRY
BRICK MASONRY, CHEMICALLY
RESISTANT MEMBRANE
STEEL
FINISH WOOD
PLYWOOD
RIGID INSULATION
GYPSUM WALL BOARD
BATT INSULATION
SEALANT
WOOD BLOCKING
CONTINUOUS WOOD, STUD
EXISTING CONSTRUCTION
DEMOLITION
NEW CONSTRUCTION
LIMITS OF CONSTRUCTION
MATCHLINE
CENTERLINE
CONDITION ABOVE/BELOW
RATED WALL TYPE 1
RATED WALL TYPE 2
RATED WALL TYPE 3
RATED WALL TYPE 4
LINETYPES SYMBOLS ABBREVIATIONS
LIMIT OF REMOVAL
POINT OF EXISTING TO NEW
INDICATES NUMBER OF
REVISION, CORRESPONDS
WITH REVISION NOTE
DEMOLITION NOTE
CONSTRUCTION NOTE
NORTH SYMBOL
WINDOW TYPES
WALL TYPES
TOILET ACCESSORIES
FIBER CEMENT
SPRAY FOAM INSULATION
ACT ACOUSTICAL TILE
AFF ABOVE FINISHED FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
AVG AVERAGE
BD BOARD
BLDG BUILDING
BOT BOTTOM
℄ CENTERLINE
CAB CABINET
CF CUBIC FOOT
CI CUBIC INCH
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMTS CEMENTITIOUS
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CS CAST STONE
CT CERAMIC TILE
CY CUBIC YARD
DEPT DEPARTMENT
DIA, Ø DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DS DOWNSPOUT
DTL DETAIL
DWG DRAWING
(E) EXISTING
EA EACH
EBB ELECTRONIC BULLETIN BOARD
EJ EXPANSION JOINT
EL ELEVATION (ABOVE SEA LEVEL)
ELEC ELECTRIC
ELEV ELEVATION (GRAPHIC)
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRIC WATER COOLER
EXT EXTERIOR
FD FLOOR DRAIN
FF FINISH FLOOR
FIN FINISH
FL FLOOR
FRP FIBRE-REINFORCED PLASTIC
FRT FIRE RETARDANT TREATED
FSK FOIL-SCRIM-KRAFT PAPER
FT FOOT, FEET
GA GAUGE
GAL GALLONS
GALV GALVANIZED
GF GROUND FACE
GL GLASS
GWB GYPSUM WALL BOARD
GYP GYPSUM
H HIGH
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORZ HORIZONTAL
HR HOUR(S)
ID INSIDE DIAMETER
IN INCHES
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
JT JOINT
KIP THOUSAND POUNDS
KIP FT THOUSAND FOOT LBS
L LENGTH
LAM LAMINATED
LAV LAVATORY
LBS POUNDS
LF LINEAR FEET
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MPI MASTER PAINTERS INSTITUTE
MR MOISTURE RESISTANT
MTG MOUNTING HEIGHT
MTL METAL
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
OPNG OPENING
OZ OUNCE
PART PARTITION
PC POLISHED CONCRETE
PH PHASE
PL PLATE
PLAS PLASTER
PLCS PLACES
PNL PANEL
PSD PERMANENT SHADING DEVICE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAINTED
R RADIUS
R- THERMAL RESISTANT RATING
RD ROOF DRAIN
REF REFER
REINF REINFORCING
REQD REQUIRED
RM ROOM
SCH SCHEDULE
SECT SECTION
SF SQUARE FOOT, FEET
SHT SHEET
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
TCNA TILE COUNCIL OF NORTH AMERICA
TEMP TEMPERATURE
THRES THRESHOLD
TLT TOILET
TMS TANK MONITORING SYSTEM
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VAR VARIABLE
VERT VERTICAL
VOL VOLUME
W WIDTH
W/ WITH
WC WATER CLOSET
WD WOOD
WGT WEIGHT
WO WITHOUT
WP WORK POINT
WRB WATER RESISTIVE BARRIER
WWF WELDED WIRE FABRIC
YD YARD
FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR BASE WALLS
CEILING
NOTES
MATERIAL HEIGHT
101 ENTRANCE PC RUBBER GWB/PAINT ACT 9'-0" 3
102 OFFICE PC RUBBER GWB/PAINT ACT 9'-0" 3
103 OPEN OFFICE PC RUBBER GWB/PAINT ACT 9'-0" 3
104 CLOSET PC RUBBER GWB/PAINT ACT 9'-0" 3
105 UTILITY PC RUBBER GWB/PAINT GWB/PAINT 11'-2 3/8" 5
106 STAFF WORK ROOM PC RUBBER GWB/PAINT ACT 9'-0" 3
107 CORRIDOR PC RUBBER GWB/PAINT ACT 9'-0" 3
108 LOCKER ROOM PC RUBBER GWB/PAINT ACT 9'-0" 3
109 JANITOR PC RUBBER GWB/PAINT ACT 9'-0" 3, 4
110 CORRIDOR PC RUBBER GWB/PAINT ACT 9'-0" 3, 7
111 WOMEN'S RESTROOM PC CT-1 CT-1 ACT 9'-0" 2, 3
112 MEN'S RESTROOM PC CT-1 CT-1 ACT 9'-0" 2, 3
113 MAINTENANCE BAYS SC - CMU/EPOXY PAINT MR GWB/PAINT 21'-3 3/8" 1
114 STORAGE PC RUBBER GWB/PAINT ACT 9'-0" 3, 6
GENERAL NOTES:
1. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
2. ANY SURFACE FINISH NOT CLEARLY DEFINED IN THE FINISH SCHEDULE SHALL BE
FINISHED IN THE SAME MATERIALS AS SURFACES OF SIMILAR USE.
3. PAINTING, FLOORING, AND OTHER FINISHES SHALL EXTEND COMPLETELY OVER, UNDER,
AND BEHIND ANY ITEMS OR EQUIPMENT.
4. PROVIDE NON-SLIP BROOM FINISH CONCRETE AT EXTERIOR COVERED AREAS.
NOTES:
1. PROVIDE BULLNOSE CORNER CMU JAMBS AT DOOR OPENINGS 113A, 113B, 113C, AND AT WINDOW E.
2. CERAMIC TILE ON 1'-6" CMU CAVITY WALL PER TCNA DETAIL W211 (ROOM 112 ONLY) AND ON STUD
WALLS PER TCNA DETAIL W244C.
3. PROVIDE 5/8" UNFINISHED GYPSUM WALL BOARD AIR BARRIER AT TRUSS BOTTOM CHORD ABOVE
ACT. TAPE AND SEAL ALL EDGES AND PENETRATIONS.
4. PROVIDE STAINLESS STEEL WALL PANELS ON TWO WALLS AT SERVICE SINK FROM FLOOR TO 4'-0"
ABOVE FINISHED FLOOR.
5. FINISHED CEILING IS ON BOTTOM CHORD OF TRUSSES. REFER TO SECTIONS 2 AND 3 ON DRAWING A5.
6. ONLY APPLIES IF OPTION 1 IS SELECTED. SEE OPTION 1 PLANS ON DRAWING A12, IF APPLICABLE.
7. CERAMIC TILE CT-1 ON STUD WALL PER TCNA DETAIL W244C ON WALL AT DRINKING FOUNTAINS.
ABBREVIATIONS:
PC = POLISHED CONCRETE
SC = SEALED CONCRETE
CT = CERAMIC TILE
MR = MOISTURE RESISTANT
DOOR SCHEDULE
DOOR
NUMBER
DOOR
TYPE
SIZE FRAME
NOTES HARDWARE
SETWIDTH HEIGHT THICKNESS TYPE DEPTH JAMB
COND
HEAD
COND
101 D 3'-0" 7'-4" 1 3/4" F4&F5 4 1/2" - - 1, 2, 3 C 102 A 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - E
103A A 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - B 103B A 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 4 F 104 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - F 105 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - A 106 C 3'-0" 7'-0" 1 3/4" F3 6 3/4" J5 H5 1, 3 B 107 C 3'-0" 7'-0" 1 3/4" F3 6 3/4" J5 H5 1, 3 B 108 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - D 109 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 - F 111 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 4 D 112 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 4 D
113A C 3'-0" 7'-0" 1 3/4" F2 6 3/4" J2/J2A H2 1, 6 G 113B C 3'-0" 7'-3" 1 3/4" F2 6 3/4" J1/J1A H1 1, 3, 5 H 113C C 3'-0" 6'-11" 1 3/4" F2 6 3/4" J1/J1A H1 1, 3, 5 H 113D F 14'-0" 16'-3 3/4" - - - J3 H3 - - 113E F 14'-0" 16'-3 3/4" - - - J3 H3 - - 113F F 14'-0" 15'-9 1/2" - - - J3 H3 8 - 113G E 3'-0" 3'-0" 1 3/4" F1 1'-3" J6 H6 9 I 114 B 3'-0" 7'-0" 1 3/4" F1 5 3/4" J4 H4 7 F
GENERAL NOTES:
1. DOOR HARDWARE TO BE COMPLIANT WITH STANDARD FOR ACCESSIBLE AND USABLE BUILDINGS
AND FACILITIES (ICC A117.1-2017). HARDWARE SUBMITTAL SHALL INCLUDE SCHEDULE INDICATING HINGES, LOCK FUNCTIONS, LOCK BACKSET, LOCK TRIM, LEVERS, ROSE STYLE, STRIKES, FINISH, AND OPTIONS.
2. REFER TO SPECIFICATION SECTION 087100 FOR HARDWARE SETS.
3. FRAMES ARE EQUAL RABBET UON.
4. REFER TO WALL TYPES ON DRAWING A9 FOR DOOR TYPE MATERIALS.
5. PROVIDE FULLY TEMPERED SAFETY GLAZING FOR ALL DOOR VISION LITES.
NOTES:
1. PROVIDE ACCESSIBLE THRESHOLD CENTERED ON DOOR FRAME TO CONCEAL JOINT BETWEEN SLABS.
2. SEE DETAIL D/A11 FOR DOOR HEAD. DOOR JAMB AT HINGE SIDE IS SIMILAR TO J5 ON DRAWING A8.
3. DOOR SHALL BE INSULATED FOR EXTERIOR INSTALLATION.
4. PROVIDE 3/4 INCH UNDERCUT AT DOOR BOTTOM.
5. PROVIDE J1A AT LATCH SIDE.
6. PROVIDE J2A AT LATCH SIDE.
7. PROVIDE DOOR, FRAME, AND HARDWARE ONLY IF OPTION 1 IS SELECTED.
8. REMOVE DOOR IF OPTION 3 IS SELECTED.
9. COORDINATE DOOR LOCATION WITH FINAL TRUSS DESIGN TO PROVIDE MINIMUM ATTIC ACCESS
CLEARANCE OF 20" x 30".
TOILET ACCESSORY SCHEDULE
NOTE: SIZES INDICATED ARE BASIS-OF-DESIGN SELECTIONS, EQUIVALENT PRODUCTS ARE ACCEPTABLE AS APPROVED BY A/E THROUGH SUBMITTAL PROCESS.
KEY ITEM SIZE MOUNTING MOUNTING HEIGHT
A MIRROR 24"W x 36"H SURFACE 40" AFF MAX TO BOTTOM OF REFLECTING SURFACE
B PAPER TOWEL DISPENSER AND WASTE RECEPTACLE 17 3/16"W x 56"H x 8 1/8"D SEMI-RECESSED 40" AFF TO TOWEL DISPENSING AREA
C TOILET TISSUE DISPENSER 6 1/16"W x 11"H x 5 15/16"D SURFACE 29 1/2" AFF TO TOP
D COAT HOOK / DOORSTOP - SURFACE SEE SCHEDULE NOTE 2
E HORIZONTAL GRAB BAR (SIDE) 42" CONCEALED 34" TO CENTERLINE
F HORIZONTAL GRAB BAR (REAR) 36" CONCEALED 34" TO CENTERLINE
G TOWEL HOOK (ON WALL OF SHOWER AREA) 2" x 2" SURFACE 48" AFF TO TOP. SEE NOTE 4
H SANITARY NAPKIN DISPOSAL 7 1/2"W x 10"H x 3 13/16"D SURFACE 29 1/2" AFF TO TOP
J ACCESSIBLE MEN'S RESTROOM SIGNAGE - DOOR LATCH SIDE SEE SCHEDULE NOTE 3
K ACCESSIBLE WOMEN'S RESTROOM SIGNAGE - DOOR LATCH SIDE SEE SCHEDULE NOTE 3
L UTILITY SHELF WITH MOP & BROOM HOLDERS & HOOKS 34"W x 10"H x 3 13/16"D SURFACE 72" AFF TO TOP OF SHELF
M SHOWER CURTAIN ROD 36" SURFACE SEE SCHEDULE NOTE 4
N SHOWER CURTAIN AND HOOKS - - SEE SCHEDULE NOTE 4
O VERTICAL GRAB BAR 18" CONCEALED SEE SCHEDULE NOTE 1
GENERAL NOTES:
1. REFER TO PLUMBING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION ON FIXTURES.
2. SEE TYPICAL ADA ELEVATIONS AND ACCESSORY MOUNTING HEIGHTS ON DRAWINGS A9 AND A11.
3. REFER TO SPECIFICATIONS SECTION 102800 FOR TOILET ACCESSORIES.
4. INSTALL BLOCKING IN PARTITION WALLS AS REQUIRED FOR ALL GRAB BARS AND TOILET ACCESSORIES.
SCHEDULE NOTES:
1. VERIFY MOUNTING HEIGHTS OF APPROVED SUBMITTAL TO LOCATE HEIGHT OF CONTROLS, DISPENSERS, OUTLETS ETC.
PER STANDARD FOR ACCESSIBLE AND USABLE BUILDING AND FACILITIES (ICC A117.1-2017).
2. COAT HOOK / DOOR STOP LENGTH TO BE 3 INCHES. FINISH SMOOTH, NO. 4 SATIN. INSTALL TOP OF COAT HOOK AT 48" AFF.
3. ACCESSIBLE SIGNAGE SHALL BE MOUNTED 48" MINIMUM ABOVE FINISHED FLOOR TO BASELINE OF LOWEST CHARACTER LINE AND 60" MAXIMUM ABOVE FINISHED
FLOOR TO BASELINE OF HIGHEST CHARACTER LINE.
4. ITEMS G, M, AND N ARE NOT INCLUDED IN SCOPE OF WORK IF OPTION 1 IS SELECTED BY THE AGENCY. REFER TO DRAWING A12.
X
STEPHEN D. HERRING
Lic. No. 015253
04/11/2025
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
SCALE:
0 1' 5' 10'
1/4"=1'-0"
FLOOR PLAN
MAINTENANCE
BAYS
STAFF WORK
ROOM
UTILITY
OPEN
OFFICE
ENTRANCE
OFFICE
CORRIDOR
22'-8"6'-0"15'-4"3'-4"5'-4"7'-4"5'-4"4'-0"
'-0
9' -4
'-0
4' -8
69'-4"
57'-4"
4,980 SF
TV (NIC)
TV (NIC)
7' -4
2'
-8
4' -0
2'
-8
2' -8
46'-8"44'-0"25'-4"
6'-0"14'-0"6'-8"14'-0"6'-0"
MOMOMOMO
3'-4"6'-8"2'-8"6'-8"3'-4" 4"
3'-4"2'-4"1'-6"1'-6"12'-4"
MO MO MO
9' -4
M O
116'-0"
46'-8"
4'-8" 6'-8" 2'-8" 6'-8" 1'-4" 6'-0" 14'-0" 6'-8" 14'-0" 6'-0"
8' -0
MOMOMOMO
M O
'-4
4' -0
3'
-4
M O
B A2 A4
D A2 A4
C A2 A4
1'-3"44'-2"21'-8 5/8"13'-5 1/4"11 3/8"
/8
MO
5'-4"
12'-0"
4'-8"
MO
5' -8
/8
'-0
/2
/8
'-4
/8
8'
-5
/2
'-3
/8
5' -1
3/
8"
'-4
/8
'-8
/8
3' -0
/8
21'-9 1/4"11 3/8"
9'-0 5/8"9'-5 1/8"24'-6 7/8"
/8
'-6
/8
/8
1' -3
'-1 0"
1' -3
1'-3 5/8"
9'-10 1/2"
13'-4"
'-4
/8
9 1/2" 1'-4"
1' -1
0"
WOMEN'S
RESTROOM
MEN'S
RESTROOM
13'-4" 2'-0" 3'-4"
MO MO
6'-8"
1'-3"
5' -2
/8
5'
-2
/4
LOCKER
ROOM
AD
A
A A2 A4
113C
113D 113E
113F E
1' -0
J1A A2 A8
A2 A5
AIR
COMPRESSOR
(NIC)
EXHAUST
EXTRACTOR
VEHICLE
WELDER
E A2 A12
(NIC)
OPTION 3
MANAGEMENT
WIREWAYS
CONCRETE
APRON; SEE
CONCRETE
DOWNSPOUT
(TYP)
CJ
CJ
CJ
FUEL
STRUCTURAL
APRON; SEE
STRUCTURAL
ELEC PANEL
1' -6
1'
-0
J1A A2 A8
J2A A2 A8
UTILITY SINK
MOP BASIN
L
CONVENIENCE
SHOWER
ICE MACHINE
(NIC)
VEHICLE
EXHAUST
EXTRACTOR
GRINDER
DRILL
PRESS
ELEC
PANEL
(NIC)
(NIC)
FD
DOOR 113G ABOVE;
LOCATION TO BE FIELD
COORDINATE WITH FINAL
TRUSS DESIGN DURING
1' -6
" T
YP
CJ
CJ
CJ
THE SUBMITTAL PHASE
OF CONSTRUCTION
K
1' -8
TY
P
A2 A11
113A
113B
D D
B
CJ
K
L
3' -4
4'
-0
M O
D DC
A2 A5
D
D
C
C
B
G
H
E
C
D
D
D
FD
FD
FD
FD
2' -9
/8
J
E A2 A10
9" x 36"
BENCH
9" x 36"
BENCHD
A2 A10
30" x 52"
ADA
CLEAR
A 10
C A2 A10
A
RADIO/FLASHLIGHT
ALCOVE
20" x 42"
ADA BENCH
B A2 A10
CJ
B A2 A9
CJ
BB
44 105
BUILT-IN WORK
STATIONS, SEE 2/A10
A2 A10
B
4' -8
10'-8 3/8"
A A2 A12
A A2 A10
B A2 A12
OPTION 2 OPTION 1
A 4
A 4
103A
103B
A A2 A9
L
JAN
3'-5 3/4"
A
A
A
A
A
A
A
A2 A5
A2 A5
ELEC PANEL
CLOSET
3' -2
/8
4' -1
5/
8"
2'-8"
6' -4
/8
" A
J
WORK STATIONS,
SEE 2/A10
TWO (2) BUILT-IN
TWO (2)
D A2 A12
OPTION 5
EBB (NIC)
CORRIDOR
25'-4"
COAT
HOOKS
1'-2 3/4" 3'-10 3/8"
1'-6"
(NIC)
9 7/8"
4'-0"
CJ
CJ
LOUVER
CJ
CJ
CJ
H
2'-9 5/8"
7' -6
/8
A
A
ELEC PANEL
A1 A1
A1
M
COLUMNS,
TYP @
UON A1 A1
A1 A1
A A2 A11
A
A2 A11 SIM
A2 A7
A2 A7
2'-9"
7' -6
7'
-0
8"
MAX
A2 A5
CJ
PILASTER, TYPICAL
OF 5; REFER TO
STRUCTURAL
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
FLOOR PLAN
A2
GENERAL NOTES:
1. DIMENSIONS NOTED ON PLAN ARE TO FACE OF
WOOD STUD OR TO FACE OF MASONRY.
2. SEE MECHANICAL FOR LOUVERS.
3. PROVIDE TYPE 304 STAINLESS STEEL CORNER
GUARD WITH #4 SATIN FINISH ON ALL OUTSIDE
CORNERS OF GYPSUM BOARD PARTITIONS. GUARD
TO BE 48" LONG WITH RADIUS CORNER AND 2" LEGS.
CONSTRUCTION NOTES:XX
1. STAINLESS STEEL WALL PANELS ON TWO WALLS AT
SERVICE SINK TO 4'-0" ABOVE FINISHED FLOOR. PANELS
TO BE CLASS C OR BETTER PER VCC TABLE 803.13.
2. COORDINATE WITH MECHANICAL AND PLUMBING
DRAWINGS FOR REQUIRED LAYOUT, DIMENSIONS,
CLEARANCES, AND PENETRATIONS.
3. PROVIDE SIGNAGE PER SPECIFICATION SECTION 101423.
4. PROVIDE ROLLER SHADE PER SPECIFICATION SECTION
122413.
5. LAMINATE GYPSUM BOARD TO CMU WALL.
6. SEE SITE ADAPTATION FOR CONCRETE LANDINGS AND
SIDEWALKS.
7. COORDINATE THRU-BOLT OF 8" CMU PRIOR TO
INSTALLATION OF 4" GROUND FACE CMU.
8. PROVIDE ADA PULL ON INSTALL SIDE OF TOILET
PARTITION DOOR.
9. ADHERE GWB TO FACE OF COLUMN.
STEPHEN D. HERRING
Lic. No. 015253
1 SDH ENVELOPE REVISION 2026-03-11
03/11/2026
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
0 9"6"3" 1'
3"=1'-0"
DETAIL @ TYPICAL VENTED RIDGE CAPC
A3 A3
2"
ASPHALT SHINGLES
SHEATHING
UNDERLAYMENT
SYNTHETIC
SELF-ADHERED
MEMBRANE; EXTEND
RIDGE; CUT OUT AT
18" ON EACH SIDE OF
SHINGLE COVER
RIDGE FOR
VENTILATION
RIDGE VENT WITH
PLYWOOD
WATERPROOF
WOOD TRUSS
SEALANT - INSTALL BETWEEN
PIPE AND PREMANUFACTURED
MEMBRANE FLASHING AND TOOL
TO FACILITATE RUNOFF
STAINLESS STEEL CLAMPING RING
GASKETED FASTENERS - SECURE
FLASHING COLLAR FLANGE TO
SHEATHING
SET SECUREMENT RING IN
CONTINUOUS BEAD OF SEALANT
PIPE PENETRATION
PRE-FORMED
PENETRATION BOOT
CUT SHEATHING,
REQUIRED TO INSTALL
PIPE AND FLASHING
ROOFING, AND
INSULATION AS
SCALE:
0 9"6"3" 1'
3"=1'-0"
DETAIL @ TYPICAL COLD PIPE PENETRATIONB
A3 A3
SCALE:
0 9"6"3" 1'
3"=1'-0"
DETAIL @ TYPICAL STEPPED FLASHINGD
A5 A3
5" MIN
PLYWOOD SHEATHING
WOOD TRUSS
SELF-ADHERED
WATERPROOF MEMBRANE
UNDERLAYMENT
SYNTHETIC
ASPHALT SHINGLES
METAL FLASHING
UNDERLAYMENT
COUNTERFLASHING
SEALANT
CONTINUOUS BEAD OF
4" CMU
FASTENERS @ 12" OC MAX
SEALANT
PARALLEL WITH ROOF LINE
SAW CUT RUNNING
FLASHING ONE COURSE
STEPPED THRU-WALL
ABOVE ROOF FLASHING
WEEP VENTS @ 32" OC
FASTENERS @ 12" OC MAX
CONTINUOUS BEAD OF
8" M
IN
5" M
IN
8" M
IN
A3
SCALE:
3"0 6" 1' 2'
1"=1'-0"
DETAIL @ STEPPED FLASHINGA
A6 A3
D A3 A3
8"M
IN
CONTINUOUS BEAD OF
SEALANT IN SAWCUT
TOP OF ADJACENT
ROOFING
FLASHING WEEP VENT
OVERLAPPING
THROUGH-WALL
STEP FLASHING
COUNTER
A4
SCALE:
1'6"3"0 9"
1 1/2"=1'-0"
DETAIL @ BULKHEADE
A3 A3
TRUSS BEARING
(+11'-3")
B/ACT
SEE FINISH
SCHEDULE
B/BULKHEAD
(+8'-0")
B/ACT
SEE FINISH
SCHEDULE
TRUSS OR WOOD
2x4 STUDS @ 16" OC
5/8" GWB
(2) 2x6 HEADER
WITH 1/2" PLYWOOD
BLOCKING
5/8" UNFINISHED GWB
AT BOT CHORD; TAPE
AND SEAL ALL EDGES
AND PENETRATIONS
SCALE:
0 10'5' 15' 20'
1/8"=1'-0"
REFLECTED CEILING PLAN
GYPSUM BOARD
SOFFITT (+7'-4")
MAINTENANCE
BAYS
STAFF WORK
ROOM
UTILITY
OPEN
OFFICE
ENTRANCE
OFFICE
CORRIDOR
WOMEN'S
RESTROOM
MEN'S
RESTROOM
LOCKER
ROOM
JAN
CLOSET
GYPSUM BOARD
SOFFITT (+9'-4")
E A3 A3
GYPSUM BOARD
SOFFITT/CEILING
(+8'-0")
GYPSUM BOARD
SOFFITT/CEILING
(+8'-0")
CORRIDOR
GYPSUM BOARD
SOFFITT/CEILING
(+9'-4")
A3 A11
SCALE:
0 10'5' 15' 20'
1/8"=1'-0"
ROOF PLAN
2'-0" MIN 2'-0" MIN1'-6" MIN1'-6" MIN
2' -0
" M
IN
C A3 A3
SLOPE
5:12
SLOPE
5:12
B A3 A3
D A3 A3
B A3 A3
C A3 A3
B A3 A3
2' -0
" M
IN
SELF-ADHERED
WATERPROOFING
MEMBRANE, TYP
2' -0
" M
IN
SL
O
PE
5:
SL
O
PE
5:
SL
O
PE
5:
1' -6
" M
IN
1' -6
" M
IN1'
-6 " M
IN
1'
-6 " M
IN
2'-0" MIN
C
A3 A3
DOWNSPOUT, TYP
GUTTER, TYP
LINE OF WALL
BELOW, TYP
2' -0
" M
IN
2' -0
" M
IN
A A3 A5
A A3 A5
A A3 A5
D A3 A3
SIM @ LOW ROOF
SIM @ RAKE
FOR DWH-1 VENT
SEE DRAWING P1
3" x 4"
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
REFLECTED CEILING AND ROOF PLANS
AND DETAILS
A3
REFLECTED CEILING PLAN LEGEND:
2'x2' SUSPENDED ACOUSTICAL CEILING PANEL (ACP)
SUPPLY AIR DIFFUSER
RETURN GRILLE
LIGHTING LUMINAIRE
GYPSUM WALL BOARD SOFFITT OR CEILING
RECESSED EMERGENCY DOWNLIGHT
CEILING MOUNTED, SINGLE-FACED EXIT SIGN
CONSTRUCTION NOTES:XX
1. 20" x 30" ATTIC ACCESS OPENING AND PLYWOOD PANEL WITH PERMANENTLY
ATTACHED INSULATION TO MATCH SPECIFIED ATTIC INSULATION PER VCC
1209.2. FIELD VERIFY OPENING LOCATION.
2. PROVIDE MANUFACTURED GWB CONTROL JOINT AT MIDPOINT AND PERIMETER
RELIEF JOINT ALL AROUND IN MAINTENANCE BAYS.
3. PROVIDE ATTIC VENTS PER SPECIFICATION SECTION 073113. PROVIDE 52 LF
RIDGE VENT ABOVE OFFICE AND 41 LF RIDGE VENT ABOVE MAINTENANCE BAYS.
PROVIDE ONE UNDEREAVE SOFFIT VENT IN EACH TRUSS BAY THAT DOES NOT
HAVE SHEAR COLLECTOR BLOCKING.
GENERAL NOTES:
1. REFER TO ELECTRICAL DRAWINGS FOR LIGHTNING PROTECTION SYSTEM.
2. REFER TO PLUMBING AND MECHANICAL DRAWINGS FOR ROOF PENETRATIONS.
3. REFER TO SITE ADAPTATION FOR DOWNSPOUT COLLECTION BELOW GRADE.
4. PROVIDE SHINGLE ROOFING SYSTEM INCLUDING ALL FASTENERS,
UNDERLAYMENT, AND FLASHING.
5. PROVIDE CONTINUOUS REMOVABLE LEAF GUARDS OF STAINLESS STEEL OR
ALUMINUM DESIGNED TO SHED LEAVES. INSTALL CONTINUOUS LEAF GUARDS
ON GUTTERS WITH NONCORROSIVE FASTENERS, REMOVABLE FOR CLEANING
GUTTERS.
EMERGENCY LIGHTING LUMINAIRE
INFRARED HEATER
STEPHEN D. HERRING
Lic. No. 015253
CEILING MOUNTED VACANCY / OCCUPANCY SENSOR
CEILING MOUNTED OCCUPANCY SENSOR
1 SDH ENVELOPE REVISION 2026-03-11
03/11/2026
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
0 10'5' 15' 20'
1/8"=1'-0"
ELEVATIONA
A2 A4 SCALE:
0 10'5' 15' 20'
1/8"=1'-0"
ELEVATIONB
A2 A4
SCALE:
0 10'5' 15' 20'
1/8"=1'-0"
ELEVATIONC
A2 A4 SCALE:
0 10'5' 15' 20'
1/8"=1'-0"
ELEVATIOND
A2 A4
GF CMU #2
GF CMU #1
GF CMU #2
GF CMU #1
CMU #2
CMU #1
CMU #2
CMU #1
GF CMU #2
GF CMU #1
CMU #2
GF
CMU #2
CMU #1
GF CMU #2
LIGHT
GF CMU #2
GF CMU #1
GF CMU #2
GF CMU #1
GF CMU #2
GF CMU #1
GF CMU #2
LIGHT
GF CMU #2
GF CMU #1
GF CMU #1
GF CMU #2
GF CMU #1
BOLLARD;
TYPICAL
DS W/CJ DS
ASPHALT
SHINGLES
RIDGE
VENT
SHINGLES
ASPHALT
VENT
RIDGE
BOLLARD
FIN FLOOR
(+0'-0")
FIN FLOOR
(+0'-0")
FIN FLOOR
(+0'-0")
FIN FLOOR
(+0'-0")
SHINGLES
ASPHALT
VENT
RIDGE
BOLLARD
DSDSDS W/CJ
LIGHT
BOLLARD
ASPHALT
SHINGLES
RIDGE
VENT
DS W/CJ
DS
DS LOUVER DS W/CJ
DS
HOLLOW
METAL DOOR
STOREFRONT
SYSTEM
ALUMINUM
WINDOW
STOREFRONT
SYSTEM
ALUMINUM
WINDOWS
GF CMU #2
FIBER
OVERHEAD
SECTIONAL DOOR
OVERHEAD
SECTIONAL DOOR
CEMENT
FIBER
CEMENT
EXHAUST
BOLLARD;
TYPICAL
TRUSS
BEARING
(+21'-4") AFF
TRUSS
BEARING
(+21'-4") AFF
TRUSS
BEARING
(+21'-4") AFF
TRUSS
BEARING
(+11'-3") AFF
GF CMU #1
LIGHT
LIGHT
GF CMU #1
TRUSS
BEARING
(+21'-4") AFF
LIGHT
TRUSS
BEARING
(+11'-3") AFF
TRUSS
BEARING
(+11'-3") AFF
BEHIND BEHIND
CJ
FLASHING
KICKOUT
BEHIND
DS W/CJ
BEHIND
DS W/CJ
BEHIND
CJ DS W/CJ
BEHIND
FLASHING
KICKOUT
LIGHT
DS
GF
CMU #1
GF
GF
GF
GF
GF
GF
VENT
LIGHT
CJ
DS W/CJ
BEHIND
DS W/CJ
BEHIND
DS W/CJ
BEHIND
BEHIND
DS W/CJ
BEHIND
A A4 A3
A A4 A7
WINDOW
ALUMINUM
LIGHT
LIGHT
LIGHT
DUCT
PENETRATIONS
LOUVER
LOUVER
REFER TO DETAIL A
ON DRAWING M5 FOR
FLASHING DETAIL
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
ELEVATIONS
A4
STEPHEN D. HERRING
Lic. No. 015253
1 SDH ENVELOPE REVISION 2026-03-11
03/11/2026
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
CORRIDOR
STAFF WORK ROOM
SCALE:
0 10'5'
3/16"=1'-0"
BUILDING SECTION3
A2 A5
TRUSS
BEARING
(+11'-3")
AFF
A5 A6
UTILITY
T/BUILDING
(+20'-1"±) AFF
T/BUILDING
(+32'-2"±) AFF
TRUSS
BEARING
(+21'-4")
AFF
SCALE:
0 10'5'
3/16"=1'-0"
BUILDING SECTION1
A2 A5
SLOPES;
SEE
FLOOR
STRUCT
DWGS
MAINTENANCE
BAYS
TRUSS
BEARING
(+11'-3")
AFF
WOMEN'S
REST-
STAFF WORK ROOM
OPEN
OFFICE
ROOM
MEN'S
REST-
ROOM
A5 A6
A5 A6 SIM
T/SLAB
GRADE
LINE
AVERAGE
ROOF
HEIGHT
'-7
3/
4"
A A5 A5
A A5 A5
SIM
@ RAKE
D A3A5
OPP HAND
@ LOW ROOF
A5 S5OPP HAND
B/ACT
(+9'-0")
AFF
FILL ANY
VOIDS WITH INSULATION
SCALE:
1'6"3"0 9"
1 1/2"=1'-0"
DETAIL @ RAKEA
A5 A7
6"
FIBER CEMENT TRIM
FIBER CEMENT SOFFITT
4" GF CMU #2
1 1/2" RIGID INSUL; R-7.5 MIN
1/2" GYPSUM SHEATHING
AIR GAP
FLUID APPLIED AIR BARRIER
1/2" GYPSUM SHEATHING
AIR GAP
END TRUSS; SEE STRUCTURAL
TRUSS BEARING
(+11'-3") AFF
1 1/2" RIGID INSULATION; R-7.5
MIN
ADJUSTABLE VENEER
ANCHORS @ 16" OC
ON SYNTHETIC
ASPHALT SHINGLES
FIBER CEMENT
METAL DRIP EDGE
UNDERLAYMENT
FASCIA
5/8" GWB AIR
BARRIER
15" BATT
INSULATION;
R-49 MIN
10"
PLYWOOD
SHEATHING
WATERPROOFING
MEMBRANE; REFER
LOCATIONS
EXTEND GYPSUM
BETWEEN RIGID INSUL
AND ATTIC SPACE
SELF-ADHERED
TO ROOF PLAN FOR
PLYWOOD TO PROVIDE SEPARATION
SHEATHING TO UNDERSIDE OF
OUTRIGGER;
SEE STRUCT
BLOCKING AND GWB
BETWEEN EACH
OUTRIGGER
2 x 4 STUDS @ RAKE
A3
B/ACT
(+9'-0") AFF
TRUSS
BEARING
(+11'-3")
AFF
SCALE:
0 10'5'
3/16"=1'-0"
BUILDING SECTION4
A2 A5 SCALE:
0 10'5'
3/16"=1'-0"
BUILDING SECTION5
A2 A5
CORRIDOR
LOCKER
WOMEN'S
RESTROOM
ROOM
B A5 A7
OPEN
OFFICE
ENTRANCE
TRUSS
BEARING
(+11'-3")
AFF
A5 A6
D A5 A7
T/BUILDING
(+20'-1"±) AFF
T/BUILDING
(+18'-1"±) AFF
A5 A6 SIM
OPP HAND
SCALE:
0 9"6"3" 1'
3"=1'-0"
TYPICAL CONTROL JOINT DETAIL
NOTE:
CONTINUE JOINTS THROUGH CMU BASE COURSES.
4" GROUND FACE
BACKER ROD AND
SEALANT
AIR GAP
VERTICAL
CMU TIES @ 16" OC
CMU VENEER
2x4 STUDS
1 1/2" RIGID INSUL;1/2" GWB
R-7.5 MINIMUMSHEATHING
SCALE:
0 10'5'
3/16"=1'-0"
BUILDING SECTION2
A2 A5A1
UTILITY
TRUSS
BEARING
(+11'-3")
AFF
GWB
PROVIDE GASKETING
AROUND DUCT
OPENING IN FRAMING/
GWB TO COMPLETELY
SEAL PENETRATION
D A5 A7
HVAC DUCT;
REFER TO
SECTION 2
ON DWG M4
DUCT
PENETRATIONS
CORRIDOR
A A5 A5
VIRGINIA DEPARTMENT OF TRANSPORTATION
PROTOTYPE COMBO BUILDING -
20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013
FOR STATEWIDE SITE ADAPTATION
23125 2025-04-11
DATE:PROJECT NO:
VIRGINIA A&E, PLLC
1115 VISTA PARK DRIVE
FOREST, VIRGINIA 24551
PHONE: (434) 316-6001
Drawing No.:
1"
Full Scale Verification
0"
REVISIONS DATEBYNO. COMBO BUILDING
BUILDING SECTIONS
AND DETAILS
A5
GENERAL NOTES:
1. TRUSS CONFIGURATIONS ARE DIAGRAMMATIC.
REFER TO APPROVED SHOP DRAWINGS.
STEPHEN D. HERRING
Lic. No. 015253
1 SDH ENVELOPE REVISION 2026-03-11
03/11/2026
&[Date] 194-18246-000
STATE BUILDING OFFICIAL
DIVISION OF ENGINEERING & BUILDINGS
COMMONWEALTH OF VIRGINIA
PERMIT #___________________________________
DATE: ______________________________________
APPROVED PERMIT REVISION DOCUMENTS
0 3'1'6" 2'
3/4"=1'-0"
WALL SECTION3
A5 A6 SCALE:
0 3'1'6" 2'
3/4"=1'-0"
WALL SECTION4
A5 A6SCALE:
0 3'1'6" 2'
3/4"=1'-0"
WALL SECTION1
A5 A6 SCALE:
0 3'1'6" 2'
3/4"=1'-0"
WALL SECTION2
A5 A6
TRUSS
BEARING
(+21'-4") AFF
4" FIBER CEMENT
BOARD
STRUCT DWGS
REFER TO
WOOD TRUSSES;
CLEAR AIR GAP
BAFFLE; 1"
INSULATION
RESISTANT
5/8" MOISTURE
GYPSUM BOARD
CEILING AIR
BARRIER
UNDERLAYMENT
ON SYNTHETIC
ASPHALT SHINGLES
2'-4 1/2"±
SELF-ADHERED WATER-
PROOFING MEMBRANE;
REFER TO ROOF PLAN
FOR LOCATIONS
PLYWOOD
MTL DRIP EDGE
6" GUTTER
HOLLOW METAL
DOOR FRAME; SEE
DOOR JAMB DETAIL
CONCRETE SLAB
REINFORCED
ON DWG A8
LOCATION TO BE
FIELD COORDINATED
WITH FINAL TRUSS
DESIGN DURING THE
SUBMITTAL PHASE OF
CONSTRUCTION
DOOR ;113G
TO COVER JOINT
BETWEEN SLABS
DOOR THRESHOLD
FLOOR SLOPES; SEE
STRUCT DWGS
1'-3"
CONCRETE SLAB
REINFORCED
BARRIER
VAPOR
GRAVEL
COMPACTED
ACT @ 9'-0" AFF
FOOTING; REFER TO
REINFORCED CONC
STRUCTURAL DWGS
8" CMU
4" CMU BELOW LOW
ROOF LINE
AIR BARRIER
FLUID APPLIED
DOOR
WD STUDS @ 16" OC
STEEL BEAM; REFER
TO STRUCT DWGS
4" GROUND FACE
SIDEWALK; SEE SITE
ADAPTATION PLAN
CMU #1
SURFACES; FRONT,
TOP, AND SIDES AS
REINFORCED
CONCRETE SLAB
FIBER CEMENT TRIM
COLUMN WRAP WITH
DECORATIVE CAP
ON ALL EXPOSED
GROUND FACE FINISH
REQUIRED
(3/4" THICK MINIMUM)
PROVIDE BOX BEAM
OUT OF WOOD
FRAMING AS
REQUIRED AROUND
STRUCTURAL STEEL
FRAMING TO PROVIDE
FIBER CEMENT
SOFFITT
TUBE STEEL COLUMN;
SEE STRUCT DWGS
5/8" EXTERIOR GWB
FIBER CEMENT TRIM
STOREFRONT DOOR
AND FRAME SYSTEM
(3/4" THICK MINIMUM)
GRAVEL
COMPACTED
CONCRETE SLAB
REINFORCED
VAPOR BARRIER
GRAVEL
COMPACTED
5/8" GWB
B/ACT
(+9'-0")
AFF
TRUSS
BEARING
(+11'-3")
AFF
EDGES AND
AND SEAL ALL
CHORD; TAPE
GWB AT BOTTOM
5/8" UNFINISHED
PENETRATIONS
STEP FLASHING
BARRIER
VAPOR
GRAVEL
COMPACTED
BULLNOSE JAMB
C A6 A11
D A6 A11
3" PERIMETER
INSULATION; R-15
MINIMUM
REINFORCED CONC
FOOTING; REFER TO
STRUCTURAL DWGS
A A6 A3
LAMINATE GWB TO
CMU IN CORRIDOR
AROUND DOOR 113A
AND IN LOCKER
ROOM 108; PROVIDE
CERAMIC TILE ON
CMU IN MEN'S
RESTROOM 112
A6 A9
A6 A9
ADJUSTABLE
VENEER ANCHORS
@ 16" OC
1'-3"
2'-4 1/2"±
TRUSS
BEARING
(+21'-4") AFF
4" FIBER CEMENT
BOARD
STRUCT DWGS
REFER TO
WOOD TRUSSES;
CLEAR AIR GAP
BAFFLE; 1"
INSULATION
RESISTANT
5/8" MOISTURE
GYPSUM BOARD
CEILING AIR
BARRIER
UNDERLAYMENT
ON SYNTHETIC
ASPHALT SHINGLES
ADJUSTABLE
VENEER ANCHORS
@ 16" OC
8" CMU
E A6 A7
4" x 16"
SOFFITT VENT
FIBER CEMENT
SOFFITT AND
FASCIA
6" FIBER
FLUID APPLIED
CEMENT TRIM
AIR BARRIER
1 1/4" AIR GAP
MTL DRIP EDGE
6" GUTTER
SELF-ADHERED WATER-
PROOFING MEMBRANE;
REFER TO ROOF PLAN
FOR LOCATIONS
SHEATHING
1215" BATT
INSULATION;
R-49 MINIMUM
2'-0"
MINIMUM
SHEATHING
2'-0"
PLYWOOD
MINIMUM
TRUSS
BEARING
(+11'-3") AFF
B/ACT
(+9'-0") AFF,
UON
1'-3"
1'-0"
SOFFITT VENT
FASCIA
FIBER CEMENT
SOFFITT AND
MTL DRIP
6" GUTTER
INSULATION BAFFLE;
1" CLEAR AIR GAP
PLYWOOD
SHEATHING
EDGE
STRUCT DWGS
REFER TO
WOOD TRUSSES;
UNDERLAYMENT
SHINGLES ON
ASPHALT
SYNTHETIC
CONCRETE SLAB
REINFORCED
2x4 STUDS
3 1/2" BATT INSUL;
BOARD; CONTINUE TO
5/8" GYPSUM WALL
BOTTOM CHORD
1/2" GYPSUM WALL
BOARD SHEATHING
R-13 MINIMUM
2'-1"
F
A6 A7 15" BATT
INSULATION;
R-49 MINIMUM
6" WALL BASE
SELF-ADHERED WATER-
PROOFING MEMBRANE;
REFER TO ROOF PLAN
FOR LOCATIONS
2'-0"
MINIMUM
5/8" UNFINISHED
GWB AT BOTTOM
CHORD; TAPE
AND SEAL ALL
EDGES AND
PENETRATIONS
D A6 A7
AND BASE
4" GROUND FACE
CMU #1
WITH LEAF
GUARD
WITH LEAF
GUARD
WITH LEAF
GUARD
PLYWOOD
SHEATHING
SELF-ADHERED WATER-
PROOFING MEMBRANE;
REFER TO ROOF PLAN
FOR LOCATIONS
5/8" UNFINISHED GWB
AT BOTTOM CHORD;
TAPE AND SEAL ALL
EDGES AND
PENETRATIONS
15" BATT
INSULATION;
R-49 MINIMUM
2 1/2" RIGID
INSULATION; R-11.4 CI
MIN
3" RIGID INSUL; R-15
MIN
DAMPPROOFING
CONT TO
TOP OF FOUNDATION
1 1/4" AIR GAP
3 1/2" BATT INSUL;
R-13 MINIMUM
REINFORCED
CONC FOOTING;
REFER TO
STRUCT DWGS
DAMPPROOFEING
CONT TO TOP OF
FOUNDATION
@ 32" OC
WEEP VENTS
4" x 16"
CONT MINERAL
FIBER INSUL TO
MAINTAIN
THERMAL
BARRIER
ENVELOPE, TYP
CONT MINERAL
FIBER INSUL TO
MAINTAIN
THERMAL
BARRIER
ENVELOPE
CONCRETE SLAB;
REINFORCED
VAPOR BARRIER
GRAVEL
COMPACTED
ISOLATION JOINT
FLOOR SLOPES;
SEE STRUCT DWGS
GRADE; SEE SITE
REINFORCED CONC
FOOTING; REFER TO
STRUCTURAL DWGS
ADAPTATION
2 1/2" RIGID
INSULATION; R-11.4 CI
MIN
THROUGH-WALL
JOINT @ 32" OC
FLASHING
AIR BARRIER; LAP
FLUID APPLIED
FLASHING
THROUGH-WALL
AIR BARRIER OVER
PLAN
10" DRAINAGE
4" GROUND FACE
CMU #1
4" GROUND FACE
CMU #2
3" RIGID INSUL; R-15
MIN
WEEP VENT IN HEAD
" M
AX
8" MIN T/METAL
FLASHING
MAT
3" DRIP PLATE
DAMPPROOFING
FROM…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .