160995 IFB Bryant AHQ Combo bldg Addendum 3 11.6.pdf
PDF 10 MB Posted
- Attached to
- IFB 160995 Bryant AHQ Combo & Fuel Facility
- Solicitation number
- IFB-129119
- Issued by
- New Kent County, Virginia
About this file
This is Addendum No. 3 to an Invitation for Bid (IFB 160995) issued by the Virginia Department of Transportation for construction of the Bryant Area Headquarters Combination Building and Fuel Facility located at 33 Donahue Lane, Roseland, Virginia 22967 (Project Code 501-18130-086). The addendum, dated November 6, 2026, modifies key project dates and incorporates revisions to drawings, specifications, and pre-bid questions and answers prepared by Architectural Partners. The project scope includes a 4,998-square-foot single-story prototype combo building comprising approximately 2,416 square feet of administrative office space and 2,582 square feet of vehicle storage and maintenance bay; a fuel facility with a raised concrete island featuring gasoline and diesel dispensers, automated fuel management system, and a 24-foot by 32-foot pre-engineered metal canopy; underground storage tanks (2,000 gallons gasoline and 10,000 gallons diesel); demolition of existing structures; and complete sitework, plumbing, HVAC, and electrical installations. The revised bid due date is November 18, 2026 at 2:00 p.m. EST, with bids to be opened publicly on November 19, 2026 at 2:00 p.m. EST. The prebid conference was held on October 15, 2026. Addendum 3 includes 51 pages of revisions addressing drawing additions (new Sheet G002), civil site plan modifications, revised specifications for rammed aggregate piers (Section 316613.13), and fifteen numbered questions and answers clarifying requirements for well and treatment equipment, plumbing fixtures, site water service, septic systems, gas piping connections, lead paint abatement, aggregate pier testing and inspection, fill material specifications, and dilatometer testing data.
The addendum provides critical technical clarifications through its questions and answers section, including confirmation that the existing well will serve the new building, specification of 1.28 GPF toilet flush volumes per Drawing P4, minimum lavatory trap sizes per Virginia Plumbing Code, removal of the existing septic system per Virginia Department of Health requirements, contractor responsibility for complete septic system construction and startup including controls and electrical connections, and clarification that certified propane suppliers provide tanks and regulators to 2 psig service while contractors provide downstream piping and building lockup regulators. Additional clarifications address pressure testing and purification procedures in accordance with 2021 Virginia Fuel Gas Code and NFPA 58, lead paint abatement as contractor responsibility per OSHA regulations, project inspector involvement limited to verifying general pier location with final confirmation as contractor responsibility, acceptance of compacted #10 screenings as structural fill material, and provision of complete DMT test results and data as Appendix 4. Acknowledgement of Addendum 3 or any subsequent addenda is mandatory prior to the bid due date and time, or must be signed and uploaded with the electronic bid submission, with failure to acknowledge potentially rendering bids non-responsive.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEPARTMENT OF TRANSPORTATION
Stephen C. Brich, P.E. 1221 East Broad Street (804) 482-5818 Commissioner Richmond, Virginia 23219 November 6, 2026
ADDENDUM No. 3 TO ALL BIDDERS:
Reference-IFB: 160995 Commodity Bryant AHQ Combo Building and Fuel Center
Project Code: 501-18130-086 Dated: October 5, 2026
For Delivery To: Virginia Department of Transportation (VDOT) Attention: Joshua Saunders
Bids Due: November 18, 2026 @ 2:00PM Prebid Conference October 15, 2026
The above is hereby changed to read:
1. In reference to Bid Due Date: Change to read “The deadline for submitting bids is 2:00 P.M. EST, as determined by the bid officer, on November 18, 2026."
2. In reference to Bid Opening Date: Changed to read “The bids will be opened publicly and read aloud beginning at 2:00 P.M EST on November 19, 2026."
3. In Reference to Addendum #3 sealed by Brian Goldman of Architectural Partners (51 pages) to include revisions to the drawings, project manual, and the Pre-bid questions and answers.
Note:
Acknowledgement of this addendum or any subsequent addenda must be prior to the bid due date and time or signed and uploaded as an attachment with the electronic bid submission. Failure to acknowledge or submit the addendum may be grounds for declaring the bid non-responsive.
Sincerely, Joshua Saunders Joshua Saunders, VCCO, VCO, Senior Procurement Officer
Name of Firm
Signature Title Date
A d d e n d u m
PROJECT INFORMATION
OWNER NAME: VIRGINIA DEPT. OF TRANSPORTATION OWNER PROJECT MGR: JOHN DYER
PROJECT TITLE: VDOT -- BRYANT AHQ -- COMBO BUILDING
& FUEL FACILITY
OWNER PROJECT NO.: 501-18130-086
A/E PROJECT MGR.: BRIAN E. GOLDMAN, RA
PROJECT LOCATION: 33 DONAHUE LANE,
ROSELAND, VA 22967
BIDS DUE: REFER TO VDOT ADDENDUM
IFB NO.: 160995 BID OPENED: SEE COVER LETTER
ADDENDUM #: 3
This addendum becomes part of the Construction Documents. The following changes, additions, and deletions shall be made to the following documents; all other conditions shall remain the same. Please attach to all copies of the
Construction Documents which you are holding.
All Contractors are to state in their bid the receipt of this addendum. Instructions to Bidders:
ADDENDUM TO THE DRAWINGS – DRAWINGS:
Number Drawing Detail No.
G001 PROJECT COVER SHEET Re-issued to reflect addition of Sheet G002.
G002 NEW SHEET Added per DEB WD-4 review comments.
2C1.0 CIVIL / SITE SHEET Revised per DEB WD-4 review comments.
ADDENDUM TO THE PROJECT MANUAL VOLUME 1 & 2:
Number Spec Section Specification Change
Table of Contents Re-issued to reflect addition of Sheet G002.
316613.13 – Rammed Aggregate Piers Revised section dated 10-29-2026 issued per DEB WD-4 comments. See attached.
Appendix 4 - Addendum 2 GER
20250770 Full report with DMT Results.
QUESTIONS/ANSWERS AND CLARIFICATIONS:
Number
A3Q1 Question
Well and treatment equipment: Please identify the required well pump, pressure tank, controls, water testing, and treatment equipment, including equipment in Utility Room
105. Please clarify the contract requirements and plumbing connection points.
(General - Utility Room 105)
Answer The existing well on the property is being used to serve the new building. Please refer to
Drawing C200.
A3Q2 Question
Toilet flush volume: Drawing P4 specifies 1.28-GPF tank-type toilets, while Section
224100, paragraph 2.4, specifies 1.6 GPF. Which requirement governs? (P4 /
224100.2.4)
Answer The scheduled value of 1.28 GPF on Drawing P4 governs.
A3Q3 Question
Lavatory trap size: Drawing P4, fixture note 11, specifies a 1-1/4" trap, while Section
224200, paragraph 2.2.D.3, specifies a 1-1/2" trap. Which size is required? (P4 /
224200.2.2.D.3)
Answer Minimum lavatory trap size per Virginia Plumbing Code is 1-1/4”
A3Q4 Question
Site water: Please confirm the limits and connection requirements for the 2" water service, site backfeed, and 1" branch serving the fuel station, including connections to existing piping. (General - site water)
Answer
Please refer to Drawing C200 for site water line and connection point information.
See civil drawings (C-series) for water service routing, connection points, and backflow requirements. Contractor shall coordinate final connections with the utility and existing piping as shown.
A3Q5 Question
New septic system: Please confirm the complete required scope for the septic tank, Orenco treatment package, distribution box, drainfield, startup, and service agreement, including controls and electrical connections. (General - new septic system)
Answer The contractor’s scope includes construction and startup of the entirety of the new septic system, including all controls and electrical connections.
A3Q6 Question
Existing septic system: Please clarify whether the existing tank and drainfield must be removed or may be abandoned in place, and identify the required pumping, disposal, backfill, and restoration. (General - existing septic system)
Answer The existing tank and drainfield are to be removed per VDH requirements; please refer to Drawing C101.
A3Q7 Question
Sewer elevation: The sanitary structure schedule on C200 lists a cleanout invert of
769.00, which appears inconsistent with adjacent elevations. Please confirm or provide the corrected elevation. (C200)
Answer This invert should be corrected to 869.00.
A3Q8 Question
Equipment connections: Please confirm the required gas-piping connections to both infrared heaters, the HVAC unit, the tankless water heater, and the generator.
(General - gas piping)
Answer
See Site adapt drawing 2M1.0 along with Specification 231126.
General Response: Both invoke NFPA 58 and the 2021 Virginia Fuel Gas Code
(especially section 411 covering ANSI/CGA Listed and Labeled gas connectors for both indoor and outdoor appliances (generator) to be installed per Manufacturer’s instructions).
Above is invoked in 2M1.0 PLAN NOTES especially NOTES 1 & 7.
2M1.0 has under plan title MECHANICAL PLAN to “NOTE: REFER TO APPROVED
PROTOTYPE DRAWINGS…” as PLAN has piping at each appliance stating to “SEE
DETAIL ON …AND SCHEDULE ON…”. Each DETAIL provides additional appliance installation and gas piping connection requirements and SCHEDULE notes to see individual appliance Project Manual Book Specification for installation and gas connection requirements.
A3Q9 Question
Supplier boundary and regulators: Please identify where the propane supplier's scope ends and the installing contractor's scope begins, including underground piping and the generator branch. M2 note 5 assigns the building lockup regulator to the contractor, while 2M1.0 assigns tank pressure regulators and associated equipment to the certified supplier. Please clarify responsibility for the building regulator and its vent piping. (M2 / 2M1.0)
Answer
Certified propane supplier provides tank, tank regulators to provide 2 psig service, and equipment up to the point of connection as indicated on 2M1.0. Contractor provides underground piping and aboveground piping with transition anodeless risers, supports, protection, building lockup MP regulator and required components per M2
Note 5, 2021 VFGC section 410, and Specification 231126. This is also to include vent piping as applicable, strainers, pressure gages, shut-off valves, all downstream distribution and Line Pressure Regulator and connector for generator. Coordinate final point of connection with supplier and comply with all requirements per 2M1.0 PLAN
NOTE 1 therein 2021 VFGC, NFPA 58 and International Fire Code.
A3Q10 Question
Final gas sizing: 2M1.0 note 8 indicates that final sizing is pending generator selection and gas-supplier information. Please provide coordinated pipe sizes and regulator requirements for bidding or identify the required bidding basis. (2M1.0)
Answer
Bid on the basis of the pipe sizes and regulator requirements shown on the drawings and response to A3Q9. Certified Propane Supplier to install and certify items noted in
2M1.0 LPG DIAGRAM for 2 psig service Point of Delivery. Pending final line routing by
Civil and Contractor, for bidding use C-200 Site and Utility Plan 450 ft of 2” SDR 11
Polyethylene Plastic Pipe. Final coordination with the selected generator and gas supplier will be performed during and prior to construction to confirm routing, LP Gas heating value and density values, Generator, etc.; no change in Base Bid is anticipated for routine coordination.
A3Q11 Question Gas testing and startup: Please clarify the contract requirements for pressure testing, purging, inspections, and coordination of appliance startup. (General - gas piping)
Answer
Perform pressure testing, purging, and inspections in accordance with the applicable gas code (2021 VFGC, NFPA 58 and Internation Fire Code), Certified Propane
Supplier instructions, appliance and equipment manufacturer requirements – all as further invoked in 2M1.0 and the Project Manual Specifications – especially
Specification 231126 section 3.10 and individual appliance specifications therein.
Coordinate appliance startup with the Owner, Certified Propane Supplier, Appliance and Equipment Suppliers instructions. All testing and startup is included in the Base
Bid.
A3Q12 Question
The following question concerns specification 024116.1.08.D. and Addendum 2, Question 4: Appendix 3 indicates the presence of lead in levels meeting or exceeding the actionable level of 1.0mg/cm2 in several locations throughout the Equipment
Storage Building. Will VDOT be performing/contracting out lead abatement in those areas per specification 024116.1.08.D?
Answer
No. Lead paint abatement required for a total building teardown is the responsibility of the Contractor. Demolition, including compliance with OSHA lead paint regulations, is a matter of the Contractor’s means and methods. This is consistent with the Lead Coating Notes on Drawing G001 and Specification Section 024116.
A3Q13 Question
The following question concerns specification 014000 and drawing 2S1.0: DGS-30-
052 indicates that the Project Inspector will be inspecting the aggregate piers for compaction, location, and tip elevation. Our assumption is that this includes the location of the holes to ensure they align with the surveyor’s footing layout; the holes after they’ve been drilled but prior to any aggregate; and every subsequent lift. It then seems that the responsibility shifts from the project inspector to the contractor, or possibly to the ground improvement firm, to carry out their own inspection of the aggregate pier load, the results of which are then sent to the A/E to ensure conformance, thus cutting out the only inspector who, until that point, has been involved with the installation of the piers from the beginning. Can you clarify whether or not, or to what extent, the project inspector should be involved with the aggregate pier load testing/inspection?
Answer
The Project Inspector’s role is as defined in DGS-30-052 and the Contract Documents.
Inspection will be limited to confirming general location per layout provided by
Contractor. Exact location confirming layout with foundation is the responsibility of the
Contractor.
A3Q14 Question
The following question concerns the geotechnical report 7.1.1.: It has been suggested that there may be difficulty sourcing enough suitable fill dirt to accomplish the necessary grading considering the on-site soils would require significant moisture conditioning. Would the geotechnical engineer approve of #10 stone as structural fill?
Answer Yes, compacted #10 screenings is acceptable.
A3Q15 Question
The following question concerns the geotechnical report, pg 3: Hurt & Proffitt's geotechnical report references five flat plate dilatometer (DMT) soundings and identifies their locations, but doesn't appear to include the actual DMT logs, profiles, or test data. Could the complete DMT results, including the interpreted soil stiffness/modulus profiles and underlying test data, be provided to bidders?
Answer See attached Appendix 4 - DMT Results Addendum 2 GER 20250770 full report.
End of Addendum
10/30/2026
VIRGINIA DEPT. OF TRANSPORTATION
VDOT Bryant Site Adapt Vol 1 PROJECT CODE: 501-18130-086
ARCHITECTURAL PARTNERS, PC 000110 - 1 Table of Contents Volume 1
VIRGINIA DEPARTMENT OF TRANSPORTATION
Bryant Area Headquarters Project Code No. 501-18130-086
TABLE OF CONTENTS
BIDDING INFORMATION FORM #
Notice of Invitation for Bid (IFB) DGS-30-256 Vendor eVA Registration Requirements (known quantities) DGS-30-384 Pre-Qualified Vendors List Instructions to Bidders DGS-30-055 (CO-7A) Prevailing Wage Determination from DOLI Prebid Question Form DGS-30-272 Bid Form DGS-30-220
GENERAL CONDITIONS
General Conditions of the Construction Contract DGS-30-054 (CO-7) Supplemental General Conditions (Liquidated Damages) DGS-30-376
SPECIAL TERMS & CONDITIONS
Small Business Subcontracting Plan
Capital Outlay Vendor Qualification Certification Form State Corporation Commission Form
Security Access Requirements
VDOT Special Provision for Storm Water Pollution Prevention Plan (SWPPP)
FORMS
The following forms are applicable to this project and can be viewed or downloaded at the DGS Forms Center or by contacting the Procurement Officer. The URL is http://forms.dgs.virginia.gov.
Contract Between Owner and Contractor DGS-30-064 (CO-9)
Workers’ Compensation Certificate of Coverage DGS-30-076 (CO-9a)
Notice to Proceed DGS-30-072 (CO-9.2)
Standard Performance Bond DGS-30-084 (CO-10)
Standard Labor & Material Payment Bond DGS-30-088 (CO10.1)
Standard Bid Bond DGS-30-090 (CO-10.2)
Contract Change Order DGS-30-092 (CO-11)
General Contractor Estimate for Change Order DGS-30-200 (GC-1) http://forms.dgs.virginia.gov/
ARCHITECTURAL PARTNERS, PC 000110 - 2 Table of Contents Volume 1
Subcontractor Estimate for Change Order DGS-30-204 (SC-1)
Sub-Subcontractor Estimate for Change Order DGS-30-208 (SS-1)
Schedule of Values and Certificate for Payment DGS-30-104 (CO-12)
Commonwealth of Virginia Affidavit of Payment of Claims DGS-30-108 (CO-13)
Certificate of Completion by Architect/Engineer or Project Manager
DGS-30-112 (CO-13.1)
Architect/Engineer’s Certificate of Substantial Completion DGS-30-116 (CO-13.1a)
Final Report of Structural Special Inspections DGS-30-120 (CO-13.1b)
Certificate of Partial or Substantial Completion by Agency Project Manager
DGS-30-128 (CO-13.1c)
Certificate of Completion by Contractor DGS-30-136 (CO-13.2)
Certificate of Partial or Substantial Completion by Contractor DGS-30-140 (CO-13.2a)
Checklist for Substantial Completion Inspection DGS-30-151 (CO-13.3s)
Document Checklist for Beneficial Occupancy DGS-30-152 (CO-13.3b)
Document Checklist for Final Completion DGS-30-153 (CO-13.3f)
Submittal Register Format DGS-30-364
LIST OF DRAWINGS
G001 PROJECT COVER SHEET
G002 PROJECT CODE DATA SHEET
CIVIL
C100 EXISTING CONDITIONS
C101 DEMOLITION AND PHASE 1 E&S PLAN
C200 SITE AND UTILITY PLAN
C201 GRADING PLAN
C202 PHASE 2 E&S PLAN
C400 BORING LOGS
C500 SITE AND UTILITY DETAILS
C501 E&S DETAILS
C600 SWPPP GENERAL INFORMATION
C601 SWPPP GENERAL INFORMATION
C602 SWPPP GENERAL INFORMATION
C603 SWPPP GENERAL INFORMATION
FUEL STATION DRAWINGS
1C1.0 FUEL CENTER COVER SHEET
ARCHITECTURAL /
STRUCTURAL
1A0.1 GENERAL INFORMATION
ARCHITECTURAL PARTNERS, PC 000110 - 3 Table of Contents Volume 1
1A1.0 FUEL STATION PLAN
1A2.0 FUEL STATION ROOF PLANS, ELEV., SECT. & DETAILS
1S0.1 LEGENDS, ABBREVIATIONS, GENERAL NOTES & TYPICAL DETAILS
1S1.0 FUEL CANOPY PLAN AND SECTIONS
MECHANICAL
1M1.0 F.S. LEGEND, ABBREV., AND SCHEDULES
1M2.0 F.S. PLANS, SECTIONS AND DETAILS
1M4.0 UST DETAILS
ELECTRICAL
1E0.1 LEGENDS, ABBREVIATIONS AND GENERAL NOTES
1E0.2 ELECTRICAL CALCULATIONS
1E1.0 FUEL STATION PLAN AND RISER DIAGRAM
1E1.1 FUEL STATION PANEL SCHEDULE AND GROUNDING
COMBO BUILDING SITE ADAPTATION DRAWINGS
2C1.0 SITE ADAPT COVER SHEET
ARCHITECTURAL
2A1.0 ARCHITECTURAL SITE PLAN
STRUCTURAL
2S1.0 RETAINING WALL PLAN, SECTIONS & DETAILS
2S1.1 SITE ADAPTATION TYPICAL DETAILS
MECHANICAL
2M1.0 MECHANICAL ADAPTATION
PLUMBING
2P1.0 SANITARY ADAPTATION
ELECTRICAL
2E1.0 OVERALL ELECTRICAL SITE PAN
2E1.1 ELECTRICAL SITE PLAN LIGHTING PHOTOMETRICS
2E2.0 ONE LINE DIAGRAM AND RACK DETAIL
2E2.1 SITE DETAILS
2E2.2 SCHEDULES AND EV CHARGING DETAILS
VDOT SUPPLIED PROTOTYPE COMBO BUILDING DRAWINGS
PROTOTYPE COMBO BUILDING - 20 OR LESS AHQ STAFF
PROJECT CODE: 501-B4501-013 DATED APRIL 11, 2025
PROTOTYPE COMBO BUILDING DRAWINGS
2C1.1 SITE ADAPT PROTOTYPE COVER SHEET
T1 TITLE SHEET
ARCHITECTURAL PARTNERS, PC 000110 - 4 Table of Contents Volume 1
FIRE PROTECTION
FP1 FIRE PROTECTION INFORMATION PLAN
ARCHITECTURAL
A1 LEGEND AND SCHEDULES
A2 FLOOR PLAN
A3 REFLECTED CEILING AND ROOF PLANS AND DETAILS
A4 ELEVATIONS
A5 BUILDING SECTIONS AND DETAILS
A6 WALL SECTIONS
A7 DETAILS AND SECTIONS
A8 WALL TYPES AND HEAD AND JAMB DETAILS
A9 DOOR, FRAME, AND WINDOW TYPES AND SECTIONS
A10 ENLARGED PLAN, ELEVATIONS, AND SECTIONS
A11 ELEVATIONS, SECTIONS, AND DETAILS
A12 OPTIONAL PLANS AND DETAILS
STRUCTURAL
S1 FOUNDATION AND SLAB PLAN
S2 STEEL FRAMING PLAN
S3 ROOF FRAMING PLAN
S4 SECTIONS AND DETAILS
S5 SECTIONS AND DETAILS
S6 ROOF TRUSS PROFILES AND SECTIONS
S7 SECTIONS, DETAILS AND OPTIONNAL PLANS
S8 GENERAL NOTES
MECHANICAL
M1 LEGEND AND SPECIFICATIONS
M2 MECHANICAL PLAN
M3 SCHEDULES
M4 OPTIONAL PLANS AND SECTIONS
M5 DETAILS
M6 CONTROLS
PLUMBING
P1 LEGEND, SPECIFICATIONS, AND DETAILS
P2 SANITARY PLAN & OPTIONAL PLAN
P3 DOMESTIC WATER PLAN
P4 PLUMBING SCHEDULES
P5 PLUMBING RISER DIAGRAMS
ELECTRICAL
E1 LEGEND, ABBREVIATIONS, AND GENERAL NOTES
E2 SINGLE LINE DIAGRAMS
E3 FLOOR PLAN - LIGHTING
ARCHITECTURAL PARTNERS, PC 000110 - 5 Table of Contents Volume 1
E4 FLOOR PLAN - POWER
E5 ENLARGED PLAN AND OPTIONAL PLANS
E6 GROUNDING AND EMBED PLAN
E7 LIGHTNING PROTECTION SYSTEM
E8 DETAILS
E9 DETAILS
E10A SCHEDULES - 120V240V, SINGLE PHASE
E10B SCHEDULES - 120V240V, 3 PHASE
E11 SCHEDULES AND CALCULATIONS
E12 SCHEMATICS
E13 CONTROL SCHEMATICS
E14 LIGHTING CONTROL SCHEMATICS
SPECIFICATIONS
DIVISION 00 – PROCUREMENT AND CONTRACTING REQUIREMENTS
000107 Seals Page 000110/1 – 000110/1
000110 Table of Contents 000110/1 – 000110/7
DIVISION 01 - GENERAL REQUIREMENTS
010000 Special Conditions 010000/1 – 010000/4 011000 Summary 011000/1 – 011000/3 012500 Substitution Procedures 012500/1 – 012500/2 013100 Project Management and Coordination 013100/1 – 013100/3 013200 Construction Progress Documentation 013200/1 – 013200/1 013300 Submittal Procedures 013300/1 – 013300/7 014000 Quality Control Services (including CO-6a, Statement of
VUSBC Special Inspections State Owned Buildings and CO-6b, 2021 VUSBC Special Inspections State Owned Buildings for each Building)
014000/1 – 014000/13
014200 References 014200/1 – 014200/1 015000 Temporary Facilities and Controls 015000/1 – 015000/4 016000 Product Requirements 016000/1 – 016000/4 017300 Execution Requirements 017300/1 – 017300/5 017400 Warranties and Bonds 017400/1 – 017400/2 017419 Construction Waste Management and Disposal 017419/1 – 017419/5 017700 Closeout Procedures 017700/1 – 017700/4 017823 Operation and Maintenance Data 017823/1 – 017823/3 017839 Project Record Documents 017839/1 – 017839/3 017900 Demonstration And Training 017900/1 – 017900/3
DIVISION 02 - EXISTING CONDITIONS
024116 Structure Demolition 024116/1 – 024116/5
DIVISION 03 – CONCRETE
Refer to Drawings and Project Manual Volume 2 for material specifications not included in Project Manual Vol 1
DIVISION 04 - MASONRY
Refer to Drawings and Project Manual Volume 2 for material specifications not included in Project Man Vol 1
ARCHITECTURAL PARTNERS, PC 000110 - 6 Table of Contents Volume 1
SPECIFICATIONS (Cont’d)
DIVISION 05 – METALS
Manual Vol 1
055000 Metal Fabrications 055000/1 – 055000/2 055213 Pipe and Tube Railings 055213/1 – 055213/2
DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES
Manual Vol 1.
DIVISION 07 - THERMAL AND MOISTURE PROTECTION
079200 Joint Sealants 079200/1 – 079200/2
DIVISION 08 - OPENINGS
DIVISION 09 – FINISHES
DIVISION 10 – SPECIALTIES
DIVISION 11 – EQUIPMENT
111136 Vehicle Charging Equipment 111136/1 – 111136/3
DIVISION 12 - FURNISHINGS
DIVISION 13 - SPECIAL CONSTRUCTION
131220 Pre-Engineered Metal Canopy 131220/1 – 131220/7
DIVISION 22 – PLUMBING
221113 Facility Water Distribution Piping 221113/1 – 221113/6 221353 Facility Septic System 221353/1 – 221353/6
DIVISION 23 - HEATING VENTILATING AND AIR CONDITIONING
231313 Facility Underground Fuel Storage Tanks 231313/1 – 231313/4 231333 Liquid-Level and Leak Detection System 231333/1 – 231333/4
DIVISION 26 – ELECTRICAL
Manual Vol 1
260543 Underground Ducts and Raceways for Electrical 260543/1 – 260543/4 260573 Electrical Coordination Analysis 260573/1 – 260573/ 5 263213 Engine Generators 263213/1 – 263213/14 263600 Transfer Switches 263600/1 – 263600/5 265613 Lighting Poles and Standards 265613/1 – 265613/5 265619 LED Exterior Lighting 265619/1 – 265619/6
DIVISION 27 – COMMUNICATIONS
ARCHITECTURAL PARTNERS, PC 000110 - 7 Table of Contents Volume 1
DIVISION 28 - ELECTRONIC SAFETY AND SECURITY
DIVISION 31 – EARTHWORK
311000 Site Clearing 311000/1 – 311000/4 DIVISION 31 – EARTHWORK (Cont’d) 312000 Earth Moving 312000/1 – 312000/10
316613.13 Rammed Aggregate Piers 316613.13/1 - 316613.13/4
DIVISION 32 - EXTERIOR IMPROVEMENTS
321216 Asphalt Paving 321216/1 – 321216/4 321313 Concrete Paving 321313/1 – 321313/12 329200 Turf and Grasses 329200/1 – 329200/9
DIVISION 33 – UTILITIES
334100 Storm Utility Drainage Piping 334100/1 – 334100/4 335700 Bulk Fuel Dispensing Equipment 335700/1 – 335700/6
APPENDIX 1 – GEOTECHINICAL ENGINEERING REPORT
APPENDIX 2 – PROTOTYPE COMBO BUILDING – SITE ADAPTION HVAC UPDATES
APPENDIX 3 – HAZARDOUS MATERIAL INSPECTION REPORTS FOR ASBESTOS AND LEAD
BASED PAINT
APPENDIX 4 – ADDENDUM GEOTECHNICAL ENGINEERING REPORT
APPENDIX 5 –PRIMARY FIRE PROTECTION PROVIDER LETTER
APPENDIX 6 – VIRGINIA DEPARTMENT OF HEALTH SEPTIC PERMIT
REFER TO PROJECT MANUAL - VOLUME 2 FOR THE FOLLOWING
PROJECT MANUAL FOR VDOT PROTOTYPE COMBO BUILDING - 20 OR LESS AHQ STAFF
(PC- 501-B4501-013)
END OF TABLE OF CONTENTS
VDOT Bryant Site Adapt Vol1 PROJECT CODE: 501-18130-086
ARCHITECTURAL PARTNERS, PC 316613.13 - 1 Rammed Aggregate Piers
SECTION 316613.13
RAMMED AGGREGATE PIERS
PART 1 GENERAL
1.01 SECTION INCLUDES
A. Shaft excavation; placement and compaction of aggregate.
B. Pier load testing.
1.02 REFERENCE STANDARDS
A. ASTM D1143/D1143M - Standard Test Methods for Deep Foundation Elements Under Static
Axial Compressive Load; 2026.
B. ASTM D4945 - Standard Test Method for High-Strain Dynamic Testing of Deep Foundations;
2026.
1.03 ADMINISTRATIVE REQUIREMENTS
A. Preinstallation Meeting: Conduct a preinstallation meeting one week prior to the start of the work of this section; require attendance by all affected installers.
1.04 SUBMITTALS
A. See Section 013000 - Administrative Requirements, for submittal procedures.
B. Shop Drawings: Indicate details and schedule of pier installation sequence.
C. Design Data: Submit the following:
1. Detailed design calculations.
2. Description of quality control and field testing program.
3. Documentation of design data sealed by Professional Structural Engineer licensed in the
State in which the Project is located.
D. Pier Load Test Report, including:
1. Location identification.
2. Description of testing equipment.
3. Calibration method and recordings.
4. Installation records.
5. Recorded data.
6. Modulus test.
7. Data analysis.
8. Recommendation of design loads.
9. Description of subsurface conditions.
10. Pier installation recommendations.
E. Field Quality Control Submittals: Submit daily.
1. Pier location.
2. Volume of aggregate.
3. Installed pier depth.
4. Number of lifts.
5. Description of placement method and forces applied.
6. Design elevation at top and bottom of pier.
7. Actual, installed elevation at top and bottom of pier.
8. Documentation of unusual or unexpected conditions encountered.
9. Description of aggregate used.
F. Designer's qualification statement.
G. Installer's qualification statement.
H. Project Record Documents: Record actual locations of piers, pier diameter, and pier length.
Accurately record the following on project record documents:
ARCHITECTURAL PARTNERS, PC 316613.13 - 2 Rammed Aggregate Piers
1. Sizes, lengths, and locations of piers and footing groups.
2. Sequence of placement.
3. Final base and top elevations.
4. Deviation from indicated locations.
1.05 QUALITY ASSURANCE
A. Designer Qualifications: Perform design under direct supervision of Professional Engineer experienced in design of this type of work and licensed in the State in which the Project is located.
B. Installer Qualifications: Company specializing in performing the work of this section with similar documented experience.
C. Testing Agency Qualifications: Independent firm specializing in performing testing and inspections of the type specified in this section.
PART 2 PRODUCTS
2.01 MATERIALS
A. Aggregate: As determined appropriate by the delegated designer.
PART 3 EXECUTION
3.01 PREPARATION
A. Use placement method that will not cause damage to nearby structures.
B. Prepare to place piers from excavated working elevation. Do not begin installation until ground elevation at each pier location is at least 12 inches (305 mm) higher than indicated top bearing level of pier.
3.02 INSTALLATION
A. Drill concentric and vertical pier shafts to diameters and depths indicated.
B. Remove loose material from shaft sides and bottom. Maintain shafts free of water.
C. Set top bearing levels of piers to elevations indicated.
D. Prepare pier top to receive spread footing.
3.03 TOLERANCES
A. Maximum Variation From Vertical: 1 in 48.
B. Maximum Variation From Design Top Elevation: 4 inches (100 mm).
C. Maximum Out-of-Position: 6 inches (152 mm).
3.04 FIELD QUALITY CONTROL
A. Field inspection and testing will be performed under provisions of Section 014000 - Quality
Requirements.
B. Use same equipment and methods for test piers as production piers.
C. Load test the following:
1. Two indicator piers at locations as directed.
D. Perform the following tests on each test pier:
1. High-strain impact test in accordance with ASTM D4945.
2. Static axial compression load test in accordance with ASTM D1143/D1143M.
3. Subject piers to 1-3/4 times design load.
E. Acceptable Permanent Set of Piers after Load Testing: 1/8 inch (3 mm).
F. Perform additional testing of other piers when tested piers do not comply with requirements.
G. Witnessed and recorded by professional engineer.
H. Compile all testing information and submit pier load test report prepared by professional engineer.
ARCHITECTURAL PARTNERS, PC 316613.13 - 3 Rammed Aggregate Piers
3.05 UNACCEPTABLE PIERS
A. Unacceptable Piers: Piers that fail, are placed out of position, are below elevations, or are damaged.
B. Abandon unacceptable piers in place or remove and replace as approved by Engineer.
END OF SECTION 316613.13
ARCHITECTURAL PARTNERS, PC 316613.13 - 4 Rammed Aggregate Piers
This page intentionally left blank
November 2, 2026
Mr. Jeffrey Godfrey, VCCO Virginia Department of Transportation
Sent via email to: Jeffrey.godfrey@VDOT.Virginia.gov
Re: Addendum 2 Geotechnical Engineering Report-DMT Results VDOT Bryant Area Headquarters (AHQ) 33 Donahue Ln, Roseland, VA 22967 H&P Project #: 20250770
Dear Jeffrey:
The purpose of this letter is to provide the dilatometer testing (DMT) results prepared by In-Situ Soil Testing, L.C., which were inadvertently omitted from our previous transmittal. H&P used these results to conduct settlement analysis and in developing ground improvement recommendations presented in our geotechnical engineering report. The attached results supplement the supporting documentation for that evaluation; no changes to the settlement estimates or recommendations presented in the report are made by this letter.
If there are any questions, please contact me at 434-546-5329 or by email at gcooke@handp.com.
Respectfully Submitted, Hurt & Proffitt, Inc.
Glenn Cooke, P.E.
Project Manager
C O
M M
O
N W
EALTH OF V
IR
G
IN
IA
P R
O
F
ESSIONAL ENGI
N
E E R
C O
M M
O
N W
EALTH OF V
IR
G
IN
IA
P R
O
F
ESSIONAL ENGI
N
E E R
Lic. No. 032685
DANIEL GLENN DAVISGLENN E. COOKE
Lic. No. 060997 11/02/2026
Addendum 2 Geotechnical Engineering Report VDOT Bryant — Nelson County, VA
Hurt & Proffitt, Inc. Attachments
Attachment 1
DMT Test Results
ED BY:
EN
G
IN
EE
R
IN
G
S U
R
VE
YI
N
G
L
AN
D D
EV
EL
O
PM
EN
T
E
N
VI
R O
N M
EN
TA
L G
EO
TE
C H
N
IC
AL
C O
N
ST
R U
C
TI
O N
T
ES
TI
N
G
IN
SP
EC
TI
O N
C
U
LT
U R
AL
R
ES
O
U R
C
ES
L A
N G
H O
R N
E R
O A
D
LY
N C
H B
U R
G V
A
4.
7.
H
A N
D P.
C O
M
THIS SHEET IS INTENDED TO BE REPRODUCED AT 11"X17". REPRODUCTION OF THIS SHEET AT A DIFFERENT SIZE THAN INTENDED SHALL VOID THE SCALE SHOWN ON THE SHEET.
IN
SP
IR
ED
R
ES
PO
N
SI
VE
TR
U
ST
ED
D
A M
H E
R S
T C
O U
N T
Y , V
IR
G
IN
IA
WV
X
X
OH
T
OH
T
OH
T
OH
T
OH
T
OH
T
O H E
O H E
AS
PH
AL
T
DIT
CH
INV IN
= 852.23' o o o o
18" ELM
C O
N C
. W
ALL
BLOCK
GARAGE
FUEL ISLAND
AND CANOPY
X X
X X
X
X
X
XXXXX
G
ATE
C H
AIN
LIN
K FEN
C
E
ED
G
E O F G
R
AVEL
FF = 872.54' +
FF = 872.4' +
(GRAVEL)
PI
T
862.70' +
862.44' +
+ 873.02'872.70' +
PA
TR
IC
K
HE
NR
Y
HI
GHW
AY
RT
E.
(V
AR
IA
BL
E W
ID
TH
R /W
455.15'
S
°5 3'2
5" W
8.
S
°3 7'
" W
S
°0 4'2
5" W
.4
4'
TANK
MANHOLE
ACCESSES
ED
G
E O
F G
R
AV
EL
861.98' +
862.09' +
862.01' +
862.07' +
862.19' +
862.37'
O H E
O H E
O H E
O H E
O H E
W
W W
W
872.89'872.87'
PROPANE
TANKS
1" = 20'
20 10 20 40
GRAPHIC SCALE IN FEET
Test Boring Location (Approximate)
B-# Test Boring Number
20250770 37°47'40.9"N 78°58'23.7"W
07/09/2024
H&P
T E
S T
B O
R
IN
G L
O C
A T
IO
N
M A
P F
O R
V
IR
G
IN
IA
D
E P
A R
T M
E N
T O
F T
R A
N S
P O
R T
A T
IO
N
B
R Y
A N
T A
R E
A H
E A
D Q
U A
T E
R S
PROJECT #
SHEET
LAT.
LONG.
DATE
DRAWN BY
SCALE
N E
LS
O
N C
O U
N T
Y , V
A
1" = 20'
N O
R
TH
B-01 B-04
B-03
B-02
DMT-2
DMT-3
DMT-5
DMT-4
DMT-6
New Building Footprint
Existing Building Footprint
SPT Borehole Locations
DMT Locations
DILATOMETER DATA LISTING & INTERPRETATION (BASED ON THE 1988 DILATOMETER MANUAL) SNDG. NO. :DMT- In-Situ Soil Testing, L.C. Page 1a JOB FILE: VDOT-Bryant FILE NO. : 2025-52 LOCATION: Roseland, Virginia SNDG.BY : Roger Failmezger, P.E., F. ASCE, D.GE SNDG. DATE: 7/25/25 ANAL.BY : Roger Failmezger, P.E., F. ASCE, D. GE ANAL. DATE: 7/27/25
ANALYSIS PARAMETERS: LO RANGE = 9.50 BARS ROD DIAM. = 3.6 CM BL.THICK. = 15.0 MM SU FACTOR = 1 SURF.ELEV. = 266.1 M LO GAGE 0 = 0.00 BARS FR.RED.DIA. = 4.4 CM BL.WIDTH = 96.0 MM PHI FACTOR = 1 WATER DEPTH = 10.0 M HI GAGE 0 = 0.00 BARS LIN.ROD WT. = 6.5 KGF/M DELTA-A = 0.24 BARS OCR FACTOR = 1 SP.GR.WATER = 1.000 CAL GAGE 0 = 0.00 BARS DELTA/PHI = 0.5 DELTA-B = 0.76 BARS M FACTOR = 1
MAX SU ID = 0.6 SU OPTION = 0 MIN PHI ID = 1.2 OCR OPTION = 0 K0 FACTOR = 1
UNIT CONVERSIONS: 1 BAR = 1.019 KGF/CM2 = 100 KPA = 1.044 TSF = 14.51 PSI 1 M = 3.2808 FT
Z ELEV THRUST A B C DA DB ZMRNG ZMLO ZMHI ZMCAL P0 P1 P2 U0 GAMMA SVP
(M) (M) (KGF) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (T/M3) (BAR)
0.40 265.70 3240 7.02 14.10 0.24 0.76 9.50 0.00 0.00 0.00 6.96 13.34 0.24 0.000 1.95 0.070
0.60 265.50 1030 2.94 6.02 0.24 0.76 9.50 0.00 0.00 0.00 3.08 5.26 0.24 0.000 1.70 0.106
0.80 265.30 640 2.39 6.17 0.24 0.76 9.50 0.00 0.00 0.00 2.49 5.41 0.24 0.000 1.70 0.139
1.00 265.10 620 1.59 4.45 0.24 0.76 9.50 0.00 0.00 0.00 1.74 3.69 0.24 0.000 1.70 0.173
1.20 264.90 580 1.04 4.03 0.24 0.76 9.50 0.00 0.00 0.00 1.18 3.27 0.24 0.000 1.60 0.205
1.40 264.70 530 0.94 2.61 0.24 0.76 9.50 0.00 0.00 0.00 1.15 1.85 0.24 0.000 1.60 0.236
1.60 264.50 460 0.66 2.72 0.24 0.76 9.50 0.00 0.00 0.00 0.85 1.96 0.24 0.000 1.60 0.268
1.80 264.30 430 0.33 2.00 0.24 0.76 9.50 0.00 0.00 0.00 0.54 1.24 0.24 0.000 1.60 0.299
2.00 264.10 530 0.87 2.93 0.24 0.76 9.50 0.00 0.00 0.00 1.06 2.17 0.24 0.000 1.60 0.331
2.20 263.90 720 1.03 3.64 0.24 0.76 9.50 0.00 0.00 0.00 1.19 2.88 0.24 0.000 1.60 0.362
2.40 263.70 800 1.20 4.20 0.24 0.76 9.50 0.00 0.00 0.00 1.34 3.44 0.24 0.000 1.70 0.394
2.60 263.50 610 1.44 3.75 0.24 0.76 9.50 0.00 0.00 0.00 1.61 2.99 0.24 0.000 1.60 0.427
2.80 263.30 430 1.23 3.08 0.24 0.76 9.50 0.00 0.00 0.00 1.43 2.32 0.24 0.000 1.60 0.458
3.00 263.10 500 2.33 6.84 0.24 0.76 9.50 0.00 0.00 0.00 2.39 6.08 0.24 0.000 1.70 0.491
3.20 262.90 840 2.88 7.55 0.24 0.76 9.50 0.00 0.00 0.00 2.94 6.79 0.24 0.000 1.80 0.525
3.40 262.70 1170 3.97 10.58 0.24 0.76 9.50 0.00 0.00 0.00 3.93 9.82 0.24 0.000 1.80 0.560
3.60 262.50 1680 8.19 16.61 0.24 0.76 9.50 0.00 0.00 0.00 8.06 15.85 0.24 0.000 1.95 0.597
3.80 262.30 1860 7.92 16.43 0.24 0.76 9.50 0.00 0.00 0.00 7.78 15.67 0.24 0.000 1.95 0.635
4.00 262.10 1840 7.17 15.27 0.24 0.76 9.50 0.00 0.00 0.00 7.06 14.51 0.24 0.000 1.95 0.674
4.20 261.90 1820 6.47 13.99 0.24 0.76 9.50 0.00 0.00 0.00 6.38 13.23 0.24 0.000 1.95 0.712
4.40 261.70 1710 4.48 11.03 0.24 0.76 9.50 0.00 0.00 0.00 4.44 10.27 0.24 0.000 1.80 0.749
4.60 261.50 1700 3.78 9.91 0.24 0.76 9.50 0.00 0.00 0.00 3.76 9.15 0.24 0.000 1.80 0.784
4.80 261.30 1660 3.60 9.37 0.24 0.76 9.50 0.00 0.00 0.00 3.60 8.61 0.24 0.000 1.80 0.819
5.00 261.10 1650 3.69 9.03 0.24 0.76 9.50 0.00 0.00 0.00 3.71 8.27 0.24 0.000 1.80 0.855
5.20 260.90 1780 3.67 9.14 0.24 0.76 9.50 0.00 0.00 0.00 3.69 8.38 0.24 0.000 1.80 0.890
5.40 260.70 1800 3.29 8.45 0.24 0.76 9.50 0.00 0.00 0.00 3.32 7.69 0.24 0.000 1.80 0.925
5.60 260.50 1770 3.35 8.36 0.24 0.76 9.50 0.00 0.00 0.00 3.39 7.60 0.24 0.000 1.80 0.961
5.80 260.30 1700 2.89 7.65 0.24 0.76 9.50 0.00 0.00 0.00 2.94 6.89 0.24 0.000 1.80 0.996
6.00 260.10 1540 2.60 6.90 0.24 0.76 9.50 0.00 0.00 0.00 2.68 6.14 0.24 0.000 1.70 1.030
6.20 259.90 1420 2.53 6.37 0.24 0.76 9.50 0.00 0.00 0.00 2.63 5.61 0.24 0.000 1.70 1.064
6.40 259.70 1430 2.45 6.39 0.24 0.76 9.50 0.00 0.00 0.00 2.54 5.63 0.24 0.000 1.70 1.097
6.60 259.50 1560 2.09 5.77 0.24 0.76 9.50 0.00 0.00 0.00 2.20 5.01 0.24 0.000 1.70 1.130
6.80 259.30 8600 3.88 10.11 0.24 0.76 9.50 0.00 0.00 0.00 3.86 9.35 0.24 0.000 1.80 1.165
:20
37.794312 -78.973208
DILATOMETER DATA LISTING & INTERPRETATION (BASED ON THE 1988 DILATOMETER MANUAL) SNDG. NO. : DMT- In-Situ Soil Testing, L.C. Page 1b JOB FILE: VDOT-Bryant FILE NO. :2025-52 LOCATION: Roseland, Virginia SNDG.BY : Roger Failmezger, P.E., F. ASCE, D.GE SNDG. DATE: 7/25/25 ANAL.BY : Roger Failmezger, P.E., F. ASCE, D. GE ANAL. DATE: 7/27/25
ANALYSIS PARAMETERS: LO RANGE = 9.50 BARS ROD DIAM. = 3.6 CM BL.THICK. = 15.0 MM SU FACTOR = 1 SURF.ELEV. = 266.1 M LO GAGE 0 = 0.00 BARS FR.RED.DIA. = 4.4 CM BL.WIDTH = 96.0 MM PHI FACTOR = 1 WATER DEPTH = 10.0 M HI GAGE 0 = 0.00 BARS LIN.ROD WT. = 6.5 KGF/M DELTA-A = 0.24 BARS OCR FACTOR = 1 SP.GR.WATER = 1.000 CAL GAGE 0 = 0.00 BARS DELTA / PHI = 0.5 DELTA-B = 0.76 BARS M FACTOR = 1
MAX SU ID = 0.6 SU OPTION = 0 MIN PHI ID = 1.2 OCR OPTION = 0 K0 FACTOR = 1
UNIT CONVERSIONS: 1 BAR = 1.019 KGF/CM2 = 100 KPA = 1.044 TSF = 14.51 PSI 1 M = 3.2808 FT
Z ELEV KD ID UD ED K0 SU QD PHI SIGFF PHIO PC OCR M SOIL TYPE
(M) (M) (BAR) (BAR) (BAR) (DEG) (BAR) (DEG) (BAR) (BAR)
0.40 265.70 99.37 0.92 222 6.58 30.99 442.7 1035 SILT
0.60 265.50 29.07 0.71 76 3.43 6.88 65.1 266 CLAYEY SILT
0.80 265.30 17.90 1.17 101 2.61 4.25 30.5 309 SILT
1.00 265.10 10.07 1.12 68 1.85 2.15 12.4 170 SILT
1.20 264.90 5.76 1.77 73 0.84 19.1 39.4 0.33 35.9 0.96 4.7 143 SANDY SILT
1.40 264.70 4.85 0.61 24 1.14 0.94 4.0 43 CLAYEY SILT
1.60 264.50 3.16 1.31 39 0.59 16.2 37.2 0.43 34.0 0.55 2.1 53 SANDY SILT
1.80 264.30 1.79 1.31 24 0.43 16.6 37.1 0.48 34.1 0.31 1.0 21 SANDY SILT
2.00 264.10 3.20 1.05 39 0.83 0.69 2.1 53 SILT
2.20 263.90 3.29 1.42 59 0.57 25.5 38.2 0.59 35.6 0.74 2.0 83 SANDY SILT
2.40 263.70 3.40 1.57 73 0.59 28.2 38.2 0.64 35.8 0.84 2.1 107 SANDY SILT
2.60 263.50 3.78 0.85 48 0.94 1.15 2.7 73 CLAYEY SILT
2.80 263.30 3.12 0.63 31 0.81 0.91 2.0 40 CLAYEY SILT
3.00 263.10 4.88 1.54 128 0.95 12.7 30.5 0.74 27.8 2.50 5.1 231 SANDY SILT
3.20 262.90 5.59 1.31 134 0.95 23.3 34.2 0.82 32.0 2.88 5.5 258 SANDY SILT
3.40 262.70 7.01 1.50 204 1.09 31.9 35.6 0.89 33.6 4.27 7.6 441 SANDY SILT
3.60 262.50 13.50 0.97 270 2.21 11.74 19.7 753 SILT
3.80 262.30 12.25 1.01 274 2.08 10.74 16.9 737 SILT
4.00 262.10 10.47 1.06 259 1.89 8.92 13.2 658 SILT
4.20 261.90 8.97 1.07 238 1.72 7.40 10.4 568 SILT
4.40 261.70 5.93 1.31 202 0.92 51.7 37.1 1.20 35.7 4.07 5.4 402 SANDY SILT
4.60 261.50 4.80 1.43 187 0.77 54.6 37.6 1.26 36.3 2.96 3.8 334 SANDY SILT
4.80 261.30 4.40 1.39 174 0.73 53.9 37.3 1.32 36.1 2.73 3.3 295 SANDY SILT
5.00 261.10 4.34 1.23 158 0.74 53.2 36.9 1.37 35.8 2.84 3.3 266 SANDY SILT
5.20 260.90 4.14 1.27 163 0.70 58.7 37.4 1.43 36.3 2.69 3.0 266 SANDY SILT
5.40 260.70 3.59 1.31 152 0.63 61.4 37.6 1.49 36.6 2.23 2.4 227 SANDY SILT
5.60 260.50 3.53 1.24 146 0.63 60.0 37.2 1.54 36.3 2.31 2.4 216 SANDY SILT
5.80 260.30 2.95 1.34 137 0.56 59.4 37.1 1.60 36.2 1.88 1.9 179 SANDY SILT
6.00 260.10 2.60 1.30 120 0.54 54.3 36.4 1.64 35.5 1.72 1.7 142 SANDY SILT
6.20 259.90 2.47 1.13 103 0.66 1.48 1.4 115 SILT
6.40 259.70 2.32 1.21 107 0.53 50.8 35.5 1.73 34.7 1.67 1.5 114 SANDY SILT
6.60 259.50 1.94 1.28 98 0.46 57.8 36.4 1.80 35.7 1.33 1.2 87 SANDY SILT
6.80 259.30 3.31 1.42 191 272 SANDY SILT
:20
PR
O
JEC
T: VD
O T B ryant
IN
TER
PR
ETED
D M
T D
EFO
R M
ATIO
N
PA
R
A M
ETER
S
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger
SO
U
N D
IN
G
D M
T-4
Ground Surface Elev.: ~265.5 m
10 100 1000 DILATOMETER MODULUS, ED (bars)
D
EP
TH
, Z
(m et er s)
10 100 1000 TANGENT MODULUS, M (bars)
D
EP
TH
, Z
(m et er s)
000 10 20 30 40
STRESS (bars)
SO
U
N D
IN
G
D ATE: Jul 27, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794687 -78.973307
Water Depth: None Found
JEC
T: VD
O T B ryantD
ILATO
M
ETER
R
ESU
LTS IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G Ground Surface Elev.: ~265.5 m
CLAY SAND
0.6 1.2 0 10 20 30 40
DMT READINGS, P0 P1 (bars)
P0
P1
0.1 1.0 10.0
MATERIAL INDEX, ID
D
EP
TH
, Z
(m et er s)
100 1000 10000 THRUST (kgf)
D
EP
TH
, Z
(m et er s)
10 100 1000 BLADE STRESS, QD (bars)
Thrust
QD
Water Depth: None Found
LO
C
ATIO
N : N elson C ounty, Virginia 37.794687 -78.973307
SO
U
N D
IN
G
D ATE: Jul 27, 2025
D M
T-4
37.794312 -78.973208
D M
T-4 25
JEC
T: VD
O T B ryant
D M
T -- PR
ED
IC
TED
SETTLEM
EN
T
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G
D M
T-4
Ground Surface Elev.: ~265.5 m
10 100 1000
CONSTRAINED DEFORMATION
MODULUS, M (bars)
D
EP
TH
, Z
(m et er s)
0.0 0.5 1.0 1.5 2.0 TOTAL SETTLEMENT, S (inches)
D
EP
TH
, Z
(m et er s)
Ordinary Method--Boussinesq Special Method--Boussinesq Ordinary Method--Harr ko Special Method--Harr ko
0.0 0.5 1.0 1.5 2.0 STRESS (bars)
SO
U
N D
IN
G
D ATE: Jul 27, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794687 -78.973307
Water Depth: None Found
0 1 2 3 4 5 VERTICAL STRAIN, v, (%)
37.794312 -78.973208
D
JEC
T: VD
O T B ryant
IN
TER
PR
ETED
D M
T STR
EN
G
TH
PA
R
A M
ETER
S
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G
Note: For angles <32o, Triaxial ~ Plane.
0 1 2 3
IN-SITU COEFF.
OF LATERAL EARTH
PRESSURE, Ko
D
EP
TH
, Z
(m
0 5 10 15
HORIZONTAL
STRESS INDEX, KD
Ko
KD
0.0 0.5 1.0 1.5 2.0
UNDRAINED SHEAR
STRENGTH, Su (bars)
25 30 35 40 45 50
DRAINED FRICTION ANGLE
(degrees)
D
EP
TH
, Z
(m
Plane Triaxial
0 1 2 3 STRESS (bars)
Ground Surface Elev: ~265.5 m Water Depth: None Found
SO
U
N D
IN
G
D ATE: Jul 27, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794687 -78.973307
DM
T-4
37.794312 -78.973208
D
DILATOMETER DATA LISTING & INTERPRETATION (BASED ON THE 1988 DILATOMETER MANUAL) SNDG. NO. :DMT-3
JOB FILE: VDOT-Bryant FILE NO. : 2025-52 LOCATION: Roseland, Virginia 37.794647 -78.973167 SNDG.BY : Roger Failmezger, P.E., F. ASCE, D.GE SNDG. DATE: 7/25/25 ANAL.BY : Roger Failmezger, P.E., F. ASCE, D. GE ANAL. DATE: 7/27/25
ANALYSIS PARAMETERS: LO RANGE = 9.50 BARS ROD DIAM. = 3.6 CM BL.THICK. = 15.0 MM SU FACTOR = 1 SURF.ELEV. = 266.1 M LO GAGE 0 = 0.00 BARS FR.RED.DIA. = 4.4 CM BL.WIDTH = 96.0 MM PHI FACTOR = 1 WATER DEPTH = 10.0 M HI GAGE 0 = 0.00 BARS LIN.ROD WT. = 6.5 KGF/M DELTA-A = 0.23 BARS OCR FACTOR = 1 SP.GR.WATER = 1.000 CAL GAGE 0 = 0.00 BARS DELTA/PHI = 0.5 DELTA-B = 0.75 BARS M FACTOR = 1
MAX SU ID = 0.6 SU OPTION = 0 MIN PHI ID = 1.2 OCR OPTION = 0 K0 FACTOR = 1
UNIT CONVERSIONS: 1 BAR = 1.019 KGF/CM2 = 100 KPA = 1.044 TSF = 14.51 PSI 1 M = 3.2808 FT
Z ELEV THRUST A B C DA DB ZMRNG ZMLO ZMHI ZMCAL P0 P1 P2 U0 GAMMA SVP
(M) (M) (KGF) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (T/M3) (BAR)
0.40 265.70 2520 1.68 7.88 0.23 0.75 9.50 0.00 0.00 0.00 1.65 7.13 0.23 0.000 1.80 0.070
0.60 265.50 1060 1.09 5.93 0.23 0.75 9.50 0.00 0.00 0.00 1.13 5.18 0.23 0.000 1.80 0.105
0.80 265.30 440 1.71 3.56 0.23 0.75 9.50 0.00 0.00 0.00 1.90 2.81 0.23 0.000 1.60 0.139
1.00 265.10 520 2.22 5.50 0.23 0.75 9.50 0.00 0.00 0.00 2.34 4.75 0.23 0.000 1.70 0.171
1.20 264.90 600 2.02 5.00 0.23 0.75 9.50 0.00 0.00 0.00 2.15 4.25 0.23 0.000 1.70 0.204
1.40 264.70 580 1.63 4.31 0.23 0.75 9.50 0.00 0.00 0.00 1.78 3.56 0.23 0.000 1.70 0.238
1.60 264.50 490 1.75 3.36 0.23 0.75 9.50 0.00 0.00 0.00 1.95 2.61 0.23 0.000 1.60 0.270
1.80 264.30 380 1.68 3.08 0.23 0.75 9.50 0.00 0.00 0.00 1.89 2.33 0.23 0.000 1.60 0.302
2.00 264.10 550 2.27 5.38 0.23 0.75 9.50 0.00 0.00 0.00 2.39 4.63 0.23 0.000 1.70 0.334
2.20 263.90 900 2.64 7.37 0.23 0.75 9.50 0.00 0.00 0.00 2.68 6.62 0.23 0.000 1.80 0.368
2.40 263.70 1130 4.23 9.59 0.23 0.75 9.50 0.00 0.00 0.00 4.24 8.84 0.23 0.000 1.80 0.404
2.60 263.50 1550 7.64 15.30 0.23 0.75 9.50 0.00 0.00 0.00 7.54 14.55 0.23 0.000 1.95 0.440
2.80 263.30 1780 9.09 17.25 0.23 0.75 9.50 0.00 0.00 0.00 8.96 16.50 0.23 0.000 1.95 0.479
3.00 263.10 1780 8.20 16.39 0.23 0.75 9.50 0.00 0.00 0.00 8.07 15.64 0.23 0.000 1.95 0.517
3.20 262.90 1760 6.78 15.36 0.23 0.75 9.50 0.00 0.00 0.00 6.63 14.61 0.23 0.000 1.95 0.555
3.40 262.70 1790 5.90 14.54 0.23 0.75 9.50 0.00 0.00 0.00 5.75 13.79 0.23 0.000 1.95 0.594
3.60 262.50 1830 4.42 11.32 0.23 0.75 9.50 0.00 0.00 0.00 4.35 10.57 0.23 0.000 1.80 0.630
3.80 262.30 1850 4.15 11.87 0.23 0.75 9.50 0.00 0.00 0.00 4.04 11.12 0.23 0.000 1.80 0.666
4.00 262.10 1800 3.74 9.82 0.23 0.75 9.50 0.00 0.00 0.00 3.72 9.07 0.23 0.000 1.80 0.701
4.20 261.90 1590 2.62 7.60 0.23 0.75 9.50 0.00 0.00 0.00 2.65 6.85 0.23 0.000 1.80 0.736
4.40 261.70 1650 2.72 7.25 0.23 0.75 9.50 0.00 0.00 0.00 2.77 6.50 0.23 0.000 1.80 0.772
4.60 261.50 1530 2.10 6.14 0.23 0.75 9.50 0.00 0.00 0.00 2.18 5.39 0.23 0.000 1.70 0.806
4.80 261.30 1590 2.31 6.69 0.23 0.75 9.50 0.00 0.00 0.00 2.37 5.94 0.23 0.000 1.70 0.839
5.00 261.10 1620 3.15 9.39 0.23 0.75 9.50 0.00 0.00 0.00 3.12 8.64 0.23 0.000 1.80 0.874
5.20 260.90 1580 2.79 7.56 0.23 0.75 9.50 0.00 0.00 0.00 2.83 6.81 0.23 0.000 1.80 0.909
5.40 260.70 1650 3.03 7.83 0.23 0.75 9.50 0.00 0.00 0.00 3.07 7.08 0.23 0.000 1.80 0.944
5.60 260.50 1610 2.15 6.85 0.23 0.75 9.50 0.00 0.00 0.00 2.19 6.10 0.23 0.000 1.70 0.979
5.80 260.30 1620 2.70 7.19 0.23 0.75 9.50 0.00 0.00 0.00 2.75 6.44 0.23 0.000 1.80 1.013
6.00 260.10 1700 2.93 7.97 0.23 0.75 9.50 0.00 0.00 0.00 2.96 7.22 0.23 0.000 1.80 1.048
6.20 259.90 1710 2.93 7.53 0.23 0.75 9.50 0.00 0.00 0.00 2.98 6.78 0.23 0.000 1.80 1.084
6.40 259.70 1730 3.22 8.15 0.23 0.75 9.50 0.00 0.00 0.00 3.25 7.40 0.23 0.000 1.80 1.119
6.60 259.50 1630 3.00 7.40 0.23 0.75 9.50 0.00 0.00 0.00 3.06 6.65 0.23 0.000 1.80 1.154
6.80 259.30 1620 2.71 7.24 0.23 0.75 9.50 0.00 0.00 0.00 2.76 6.49 0.23 0.000 1.80 1.190
7.00 259.10 2060 1.47 4.72 0.23 0.75 9.50 0.00 0.00 0.00 1.59 3.97 0.23 0.000 1.70 1.224
7.20 258.90 4500 1.89 8.82 0.23 0.75 9.50 0.00 0.00 0.00 1.82 8.07 0.23 0.000 1.80 1.258
DILATOMETER DATA LISTING & INTERPRETATION (BASED ON THE 1988 DILATOMETER MANUAL) SNDG. NO. : DMT-3
JOB FILE: VDOT-Bryant FILE NO. :2025-52 LOCATION: Roseland, Virginia 37.794647 -78.973167 SNDG.BY : Roger Failmezger, P.E., F. ASCE, D.GE SNDG. DATE: 7/25/25 ANAL.BY : Roger Failmezger, P.E., F. ASCE, D. GE ANAL. DATE: 7/27/25
ANALYSIS PARAMETERS: LO RANGE = 9.50 BARS ROD DIAM. = 3.6 CM BL.THICK. = 15.0 MM SU FACTOR = 1 SURF.ELEV. = 266.1 M LO GAGE 0 = 0.00 BARS FR.RED.DIA. = 4.4 CM BL.WIDTH = 96.0 MM PHI FACTOR = 1 WATER DEPTH = 10.0 M HI GAGE 0 = 0.00 BARS LIN.ROD WT. = 6.5 KGF/M DELTA-A = 0.23 BARS OCR FACTOR = 1 SP.GR.WATER = 1.000 CAL GAGE 0 = 0.00 BARS DELTA / PHI = 0.5 DELTA-B = 0.75 BARS M FACTOR = 1
MAX SU ID = 0.6 SU OPTION = 0 MIN PHI ID = 1.2 OCR OPTION = 0 K0 FACTOR = 1
UNIT CONVERSIONS: 1 BAR = 1.019 KGF/CM2 = 100 KPA = 1.044 TSF = 14.51 PSI 1 M = 3.2808 FT
Z ELEV KD ID UD ED K0 SU QD PHI SIGFF PHIO PC OCR M SOIL TYPE
(M) (M) (BAR) (BAR) (BAR) (DEG) (BAR) (DEG) (BAR) (BAR)
0.40 265.70 23.56 3.32 190 630 SAND
0.60 265.50 10.70 3.60 141 0.95 38.2 47.7 0.18 44.3 0.77 7.3 361 SAND
0.80 265.30 13.67 0.48 32 2.23 0.34 2.78 20.1 89 SILTY CLAY
1.00 265.10 13.65 1.03 84 2.22 3.42 20.0 234 SILT
1.20 264.90 10.52 0.98 73 1.90 2.72 13.3 186 SILT
1.40 264.70 7.46 1.01 62 1.53 1.86 7.8 137 SILT
1.60 264.50 7.21 0.34 23 1.49 0.30 2.00 7.4 50 CLAY
1.80 264.30 6.26 0.23 15 1.36 0.28 1.79 5.9 31 CLAY
2.00 264.10 7.17 0.93 78 1.49 2.45 7.3 168 SILT
2.20 263.90 7.28 1.47 137 1.09 25.7 36.9 0.59 34.2 2.86 7.8 300 SANDY SILT
2.40 263.70 10.51 1.08 160 1.90 5.37 13.3 406 SILT
2.60 263.50 17.11 0.93 243 2.54 12.54 28.5 732 SILT
2.80 263.30 18.72 0.84 262 2.67 15.68 32.7 809 CLAYEY SILT
3.00 263.10 15.61 0.94 263 2.41 12.75 24.7 767 SILT
3.20 262.90 11.94 1.20 277 1.66 42.9 36.4 0.88 34.4 10.77 19.4 739 SANDY SILT
3.40 262.70 9.68 1.40 279 1.37 48.1 37.2 0.95 35.4 7.60 12.8 689 SANDY SILT
3.60 262.50 6.91 1.43 216 1.00 56.2 38.5 1.02 36.9 4.20 6.7 462 SANDY SILT
3.80 262.30 6.07 1.75 246 0.90 58.6 38.7 1.08 37.2 3.52 5.3 498 SANDY SILT
4.00 262.10 5.30 1.44 186 0.81 58.4 38.6 1.14 37.1 2.96 4.2 350 SANDY SILT
4.20 261.90 3.60 1.58 146 0.60 55.3 38.5 1.19 37.1 1.69 2.3 221 SANDY SILT
4.40 261.70 3.59 1.34 129 0.61 57.3 38.4 1.25 37.1 1.78 2.3 194 SANDY SILT
4.60 261.50 2.70 1.48 111 0.50 55.5 38.2 1.30 37.0 1.25 1.5 137 SANDY SILT
4.80 261.30 2.82 1.51 124 0.52 57.1 38.1 1.36 36.9 1.39 1.7 158 SANDY SILT
5.00 261.10 3.57 1.77 192 0.63 54.8 37.2 1.40 36.1 2.13 2.4 292 SANDY SILT
5.20 260.90 3.11 1.41 138 0.58 54.7 37.1 1.46 36.1 1.84 2.0 189 SANDY SILT
5.40 260.70 3.25 1.31 139 0.60 56.6 37.0 1.51 36.0 2.04 2.2 195 SANDY SILT
5.60 260.50 2.24 1.78 136 0.47 59.3 37.5 1.57 36.6 1.26 1.3 147 SANDY SILT
5.80 260.30 2.72 1.34 128 0.54 57.1 36.8 1.62 35.9 1.74 1.7 157 SANDY SILT
6.00 260.10 2.82 1.44 148 0.56 59.5 36.8 1.68 36.0 1.89 1.8 188 SANDY SILT
6.20 259.90 2.75 1.28 132 0.55 60.0 36.7 1.73 35.9 1.91 1.8 163 SANDY SILT
6.40 259.70 2.91 1.28 144 0.58 59.7 36.3 1.78 35.6 2.16 1.9 185 SANDY SILT
6.60 259.50 2.65 1.17 125 0.71 1.79 1.6 148 SILT
6.80 259.30 2.32 1.35 129 0.52 57.7 35.9 1.89 35.2 1.78 1.5 139 SANDY SILT
7.00 259.10 1.30 1.50 83 0.32 81.8 38.6 1.99 38.1 0.76 0.6 70 SANDY SILT
7.20 258.90 1.45 3.43 217 0.12 183.1 44.1 2.13 43.8 0.16 0.1 184 SAND
JEC
T: VD
O T B ryant
IN
TER
PR
ETED
D M
T D
EFO
R M
ATIO
N
PA
R
A M
ETER
S
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger
SO
U
N D
IN
G
D M
T-3
Ground Surface Elev.: ~266.1 m
10 100 1000 DILATOMETER MODULUS, ED (bars)
D
EP
TH
, Z
(m et er s)
10 100 1000 TANGENT MODULUS, M (bars)
D
EP
TH
, Z
(m et er s)
000 10 20 30 40
STRESS (bars)
SO
U
N D
IN
G
D ATE: Jul 26, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794647 -78.973167
Water Depth: None Found
JEC
T: VD
O T B ryantD
ILATO
M
ETER
R
ESU
LTS IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G Ground Surface Elev.: ~266.1 m
CLAY SAND
0.6 1.2 0 10 20 30 40
DMT READINGS, P0 P1 (bars)
P0
P1
0.1 1.0 10.0
MATERIAL INDEX, ID
D
EP
TH
, Z
(m et er s)
100 1000 10000 THRUST (kgf)
D
EP
TH
, Z
(m et er s)
10 100 1000 BLADE STRESS, QD (bars)
Thrust
QD
Water Depth: None Found
LO
C
ATIO
N : N elson C ounty, Virginia 37.794647 -78.973167
SO
U
N D
IN
G
D ATE: Jul 26, 2025
D
T-3
JEC
T: VD
O T B ryant
D M
T -- PR
ED
IC
TED
SETTLEM
EN
T
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G
D M
T-3
Ground Surface Elev.: ~266.1 m
10 100 1000
CONSTRAINED DEFORMATION
MODULUS, M (bars)
D
EP
TH
, Z
(m et er s)
0.0 0.5 1.0 1.5 2.0 TOTAL SETTLEMENT, S (inches)
D
EP
TH
, Z
(m et er s)
Ordinary Method--Boussinesq Special Method--Boussinesq Ordinary Method--Harr ko Special Method--Harr ko
0.0 0.5 1.0 1.5 2.0 STRESS (bars)
SO
U
N D
IN
G
D ATE: Jul 26, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794647 -78.973167
Water Depth: None Found
0 1 2 3 4 5 VERTICAL STRAIN, v, (%)
JEC
T: VD
O T B ryant
IN
TER
PR
ETED
D M
T STR
EN
G
TH
PA
R
A M
ETER
S
IN
-SITU
SO
IL TESTIN
G , L.C
EN
G
IN
EER
: R
. Failm ezger, P.E., F. ASC
E, D G
E
SO
U N
D
IN
G
Note: For angles <32o, Triaxial ~ Plane.
0 1 2 3
IN-SITU COEFF.
OF LATERAL EARTH
PRESSURE, Ko
D
EP
TH
, Z
(m
0 5 10 15
HORIZONTAL
STRESS INDEX, KD
Ko
KD
0.0 0.5 1.0 1.5 2.0
UNDRAINED SHEAR
STRENGTH, Su (bars)
25 30 35 40 45 50
DRAINED FRICTION ANGLE
(degrees)
D
EP
TH
, Z
(m
Plane Triaxial
0 1 2 3 STRESS (bars)
Ground Surface Elev: ~266.1 m Water Depth: None Found
SO
U
N D
IN
G
D ATE: Jul 26, 2025
LO
C
ATIO
N
: N elson C ounty, Virginia 37.794647 -78.973167
DM
T-3
DILATOMETER DATA LISTING & INTERPRETATION (BASED ON THE 1988 DILATOMETER MANUAL) SNDG. NO. :DMT-
JOB FILE: VDOT-Bryant FILE NO. : 2025-52 LOCATION: Roseland, Virginia SNDG.BY : Roger Failmezger, P.E., F. ASCE, D.GE SNDG. DATE: 7/25/25 ANAL.BY : Roger Failmezger, P.E., F. ASCE, D. GE ANAL. DATE: 7/27/25
ANALYSIS PARAMETERS: LO RANGE = 9.50 BARS ROD DIAM. = 3.6 CM BL.THICK. = 15.0 MM SU FACTOR = 1 SURF.ELEV. = 265.8 M LO GAGE 0 = 0.00 BARS FR.RED.DIA. = 4.4 CM BL.WIDTH = 96.0 MM PHI FACTOR = 1 WATER DEPTH = 10.0 M HI GAGE 0 = 0.00 BARS LIN.ROD WT. = 6.5 KGF/M DELTA-A = 0.23 BARS OCR FACTOR = 1 SP.GR.WATER = 1.000 CAL GAGE 0 = 0.00 BARS DELTA/PHI = 0.5 DELTA-B = 0.76 BARS M FACTOR = 1
MAX SU ID = 0.6 SU OPTION = 0 MIN PHI ID = 1.2 OCR OPTION = 0 K0 FACTOR = 1
UNIT CONVERSIONS: 1 BAR = 1.019 KGF/CM2 = 100 KPA = 1.044 TSF = 14.51 PSI 1 M = 3.2808 FT
Z ELEV THRUST A B C DA DB ZMRNG ZMLO ZMHI ZMCAL P0 P1 P2 U0 GAMMA SVP
(M) (M) (KGF) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (BAR) (T/M3) (BAR)
0.40 265.40 2690 3.95 11.24 0.23 0.76 9.50 0.00 0.00 0.00 3.87 10.48 0.23 0.000 1.80 0.070
0.60 265.20 1460 2.58 5.88 0.23 0.76 9.50 0.00 0.00 0.00 2.69 5.12 0.23 0.000 1.70 0.104
0.80 265.00 1170 3.07 12.14 0.23 0.76 9.50 0.00 0.00 0.00 2.90 11.38 0.23 0.000 1.90 0.140
1.00 264.80 910 2.87 7.90 0.23 0.76 9.50 0.00 0.00 0.00 2.90 7.14 0.23 0.000 1.80 0.176
1.20 264.60 940 5.07 11.96 0.23 0.76 9.50 0.00 0.00 0.00 5.01 11.20 0.23 0.000 1.80 0.211
1.40 264.40 1360 7.00 16.20 0.23 0.76 9.50 0.00 0.00 0.00 6.82 15.44 0.23 0.000 1.95 0.248
1.60 264.20 1700 7.80 16.76 0.23 0.76 9.50 0.00 0.00 0.00 7.63 16.00 0.23 0.000 1.95 0.286
1.80 264.00 1750 7.51 15.81 0.23 0.76 9.50 0.00 0.00 0.00 7.37 15.05 0.23 0.000 1.95 0.325
2.00 263.80 1720 6.44 15.06 0.23 0.76 9.50 0.00 0.00 0.00 6.29 14.30 0.23 0.000 1.95 0.363
2.20 263.60 1700 5.29 13.50 0.23 0.76 9.50 0.00 0.00 0.00 5.16 12.74 0.23 0.000 1.95 0.401
2.40 263.40 1600 4.29 11.86 0.23 0.76 9.50 0.00 0.00 0.00 4.19 11.10 0.23 0.000 1.80 0.438
2.60 263.20 1500 2.83 8.54 0.23 0.76 9.50 0.00 0.00 0.00 2.82 7.78 0.23 0.000 1.80 0.473
2.80 263.00 1450 3.46 9.66 0.23 0.76 9.50 0.00 0.00 0.00 3.43 8.90 0.23 0.000 1.80 0.509
3.00 262.80 1430 2.77 8.05 0.23 0.76 9.50 0.00 0.00 0.00 2.79 7.29 0.23 0.000 1.80 0.544
3.20 262.60 1370 2.80 7.71 0.23 0.76 9.50 0.00 0.00 0.00 2.83 6.95 0.23 0.000 1.80 0.579
3.40 262.40 1260 1.47 4.73 0.23 0.