Project Statement 22339.pdf
PDF 4 MB Posted
- Solicitation number
- RFP - 171 - 230000000199
- Issued by
- St. Clair County, Michigan
About this file
This is a Project Statement from the Michigan Department of Technology, Management and Budget (DTMB) in partnership with the Department of Natural Resources (DNR) for improvements at Algonac State Park and Wetzel State Recreation Area. The project includes expanding the sanitation station, installing full hook-up sites, replacing vault toilets, resurfacing a walking path, and constructing an outdoor classroom/picnic shelter. The mandatory pre-proposal meeting is scheduled for November 15, 2022, and proposals are due by December 8, 2022, at 2:00 p.m. Eastern. The project requires coordination with another project to pave the campgrounds. Deliverables are due at 50%, 90%, and 100% design completion, and there will be five bi-monthly design meetings during construction.
The proposal must be submitted through the SIGMA VSS system, and the total cost for all phases should be entered as the bid amount. Firms are limited to one proposal attachment of less than 6 MB. Questions should be emailed to the DTMB Project Director by November 21, 2022. The project must comply with all relevant federal, state, and local codes, standards, and regulations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 22339 Algonac As Built water_ | — | |
| Addendum 2 22339.pdf | ||
| RFP Billable Rate 22339.pdf | ||
| SAMPLE Billable Rate Contract (Rev 220207).pdf | ||
| Addendum 1 22339.pdf | ||
| Addendum 3 22339.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DTMB-0427 (R 10/22)
PROJECT STATEMENT
STATE OF MICHIGAN
DEPARTMENT OF TECHNOLOGY, MANAGEMENT AND BUDGET
State Facilities Administration
Design and Construction Division 3111 West St. Joseph Street
Lansing, Michigan 48909
FILE NUMBER
751/22339.MNB
PROPOSAL DUE DATE
Thursday, December 8, 2022, at 2:00 p.m., EASTERN CLIENT AGENCY
Department of Natural Resources
PROJECT NAME AND LOCATION
Algonac State Park and Wetzel State Recreation Area – ARPA Targeted Improvements PROJECT ADDRESS (if applicable) Algonac State Park, 8732 River Road, Marine City, MI 48039 Wetzel State Recreation Area, no street address, Use 42° 44.669’ N, 82° 50.288’ W
CLIENT AGENCY CONTACT
John Terpstra, Regional Field Planner
TELEPHONE NUMBER
248.672.7584
DTMB - DCD PROJECT DIRECTOR
Chris Bahjet
TELEPHONE NUMBER
517.749.7519
WALK-THROUGH INSPECTION DATE, TIME, AND LOCATION:
MANDATORY Pre-Proposal Meeting 10:00 a.m., EASTERN time on Tuesday, November 15, 2022, at Algonac State Park Headquarters, 8732 River Road, Marine City, MI 48039
After meeting at Algonac State Park, interested firms will then head Wetzel State Recreation Area.
(Coordinates 42° 44.669’ N, 82° 50.288’ W)
Interested firms must attend walk-throughs at both sites to be considered responsive and responsible.
MANDATORY (Check box if Mandatory)
LEIN Check (Department of Corrections ONLY) All contractor / vendor representatives attending Preproposal Walk Through Meeting must submit a Vendor / Contractor LEIN Request form five business days prior to the meeting date (See the attached Vendor/Contractor LEIN Request Form). Send the LEIN Request form, filled and signed, by email to Daniel T. Smith at email address:
smithD76@michigan.gov . The email “Subject” must include (facility name, project name, date, and time of Pre-Proposal Walk Through Meeting).
COVID 19 Precautions:
• Depending on the project location, individuals may be required to wear masks to attend meetings and for a firm to be eligible to submit bids / quotations / proposals. Bring and be prepared to wear a mask if required upon arrival. Requirements may change at any time and any updated guidance must be followed.
PROJECT DESCRIPTION/SERVICES REQUESTED
The Department of Technology, Management and Budget (DTMB) and in partnering with the Department of Natural Resources (DNR) is seeking proposals including Phase 100 through Phase 700 for design and construction administration for the following improvements at Algonac State Park and Wetzel State Recreation Area.
mailto:smithD76@michigan.gov
Improvements at Algonac State Park
• Expand the sanitation station from two (2) to four (4) lanes, due to increased demand
• Install full hook-up sites (fresh water and sanitation) in the Riverfront Campground.
This option includes the demolition of the existing bathroom building in the North Campground and providing water and sanitary service to approximately one hundred twenty (120) sites.
Improvements at Wetzel State Recreation Area
• Replace two (2) vault toilets
• Resurface an existing accessible asphalt walking path
• Construct outdoor classroom / picnic shelter
Meetings:
There will be five (5) design meetings held bi-monthly during construction.
Deliverables:
Project Deliverables will be at 50%, 90% and 100%
Coordination:
Professional needs to coordinate activities with another project to pave the campgrounds
Please NOTE:
•• Proposal responses MUST be uploaded to SIGMA VSS. Please enter the total cost for all phases as the bid amount.
•• Firms should only submit one (1) attachment (being less than 6 MB) for proposal submission. The technical is to be the technical and cost proposal combined.
• Please do not wait until just before the 2:00 p.m. solicitation deadline to submit your proposal response. SIGMA VSS will not allow a proposal to be submitted after 2:00 p.m., even if a portion of the proposal response has been uploaded.
• If you experience issues or have questions regarding your electronic submission, you must contact the SIGMA Help Desk for assistance prior to the 2:00 p.m., solicitation deadline. You may contact the SIGMA Help Desk by telephone at 517.284.0540 or toll-free at 888.734.9749. You may also email the SIGMA Help Desk at sigma-procurement-helpdesk@michigan.gov
•• Please email the Design and Construction Contract Specialists if you are having SIGMA VSS issues. Please include your SIGMA ticket number and any supporting documentation (i.e., screenshots) to Anne Watros (WatrosA@michigan.gov) and Don Klein (KleinD4@michigan.gov).
•• You may be asked by our contract specialists to email your proposal. Emailed submissions will require DCD approval and will be handled on a case-by-case basis.
•• Approved emailed submissions MUST be received prior to 2:00 p.m. deadline to be considered responsive and responsible.
•• Responses should not be emailed to the Project Director.
NIGP CODES
90610; 90638; 90672; 90682; 92517; 92533 and 92583
DESIRED SCHEDULE OF WORK
Each professional will submit their own work schedule
ACCEPTING RFP QUESTIONS UNTIL:
Please do not submit online questions via VSS. ALL questions should be emailed to Chris Bahjet at bahjetc@michigan.gov no later than 2:00 p.m., Eastern on Monday, November 21, 2022.
mailto:sigma-procurement-helpdesk@michigan.gov mailto:WatrosA@michigan.gov mailto:KleinD4@michigan.gov mailto:bahjetc@michigan.gov
REFERENCE STANDARDS: This project will comply with all codes, standards, regulations, and workers' safety rules that are administered by federal agencies (EPA, OSHA, and DOT), state agencies (DCH, EGLE, DNR, and MIOSHA), and any other local regulations and standards that may apply.
This form is required to be a part of the professional service contract. (Authority: 1984 PA 431)
Attachment(s) caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Highlight caryls Sticky Note The highlighted sites would need both sanitary and water added to them caryls Sticky Note The building between sites 124 and 128 would be removed.
caryls Sticky Note Sites 9, 301 and 303 are highlighted on the original map and not include in the project.
2"x6" BACKER FOR GRAB BAR, WITH 3" WALLS of NATURAL RESOURCES
MICHIGAN DEPARTMENT PARKS & RECREATION BUREAU
1-1-03 S1DATE: PAGE
VAULT TOILETS
NOTE: PLACE 12" OF GRANULAR MATERIAL UNDER
SIDE WALL FRAMING
VAULT FOR EVEN SUPPORT
GRILL W/ ALUM.
INSECT SCREEN AS
PROVIDE 12"x16"
SEE DETAIL A
CONCRETE VAULT
4'x8'x3'-3" DEEP
VISION-PROOF METAL
APPROVED BY OWNER
/2
7' -6
*1 '-7
M
IN
USE WATERSTOP SEALANT WHERE TOILET FLOOR
1'-9"
SLAB SEATS ON VAULT
2 GALV. NAILS EACH SIDE
2"x4"x2 3/4" LONG NAILER WITH
SLOPE TO DRAIN
SEE DETAIL B
3'-0 1/2"
F.F.
*36" MAX
PAPER HOLDER
TOILET PAPER
2"x6" BACKER FOR TOILET
HOLDER
LEFT WALL ONLY.
CENTER OF
GRAB BAR
THESE DIMENSIONS ALLOW FULL WIDTH SIDING & INTERIOR PANELS
1'-11 1/4"2'-0"9 3/4"4 1/4" 2'-0"
8'-0"
3 1/2" 7 1/4"
* DENOTES MINIMUM REQUIREMENTS
PER THE AMERICANS WITH DISIBILITIES
ACT
NOTE:
1/
2"
1/
2"
DETAIL A
1"3 1/2"
V E
N T
S P
A C
E
1/
2"
1/
2"
DETAIL B
1" 10"
VAULT TOILETS
BACK WALL FRAMING
PARKS & RECREATION BUREAUMICHIGAN DEPARTMENT
of NATURAL RESOURCES DATE: PAGE1-1-03 S2
FALSE WALL FRAMING
THESE DIMENSIONS ALLOW FULL WIDTH SIDING
2'-0"
5'-5"
F.F.
*1 '-5
2"x6" BACKER FOR GRAB BAR
GRAB BAR
CENTER OF
7' -6
7' -6
THESE DIMENSIONS ALLOW FULL WIDTH INTERIOR PANEL
THIS EDGE ASSEMBLES
TO LEFT WALL
1'-4"1/2" 2'-0" 2'-0" 1/2"
1'-8 1/2" 1'-8 1/2"
SIDING & MARK FOR
5'-5"
FRONT WALL FRAMING
7' -6
INTERIOR PANELING.
DOOR. SAME FOR
DOOR. TRIM & USE
6' -3
THIS PIECE FOR
NOTE: PLACE FULL
WIDTH SHEET OF
1' -3
8 1/2" 5" 3'-2" 8 1/2"5"
5'-5"
RIDGE VENT
8' LONG
CLEAR LEXAN OR
2'x4' SKYLIGHT
LAYERS OF SHINGLES
SKYLIGHT UNDER TWO
PLACE TOP EDGE OF
1/2" PLYWOOD
SEE DETAILS PG. M13
1'-0"
RAFTER FRAMING & DETAILS
*1 /4
" P
ER
F O
O T
M A
X . S
LO
P
E
PARKS & RECREATION DIVISION
1-1-03 S3
MICHIGAN DEPARTMENT
of NATURAL RESOURCES DATE: PAGE
1/2" SIDING
ROOF PLAN2"x4" BRACING
& NAILER (TYP)
2'x4' SKYLIGHT
V E
N T
O P
E N
I N
G
PANELING
1/2" INTERIOR
2'x4' SKYLIGHT
2' -1
/2
30%%d
4'-3"
1'-8"
1'-8"
#2 SPF (TYP)
2"x4" ROOF FRAMING
TRIM
INTERIOR ELEVATION 1"x6" CEDAR
DRIP EDGE
EQUIV.
ANCHOR
2"x4" FRAMING
PANELING
1/2" INTERIOR
EXTERIOR ELEVATION
1/2" EXTERIOR SIDING
PATTERN 111
PRIVACY SCREEN-
VAULT TOILETS
NOTE:
* DENOTES MINIMUM REQUIREMENTS
PER THE AMERICANS WITH DISIBILITIES
CEDAR TRIM ACT
DRIP EDGE
ROOF SECTION1/2" SIDING
SKYLIGHT
ROOFING FELT
8' LONG RIDGE VENT
3x1 BLACK SHINGLES
1/2" CDX PLYWOOD
2"x4" BRACING
& NAILER
1 1/2"
10"
*3 '-0
M
IN
IM
U M
ALLOWS AIR FLOW AT RIDGE VENT
2'-0"2'-0" 2'-0"
ROOF SECTION
1'-0"2'-0"
2"x4" FRAMING
PANELING
1/2' INTERIOR
ANCHOR
RAFTER FRAMING & DETAILS
3x1 BLACK SHINGLES
2"x4" BRACING & NAILER
#2 SPF (TYP)
V
E
N
T
2"x4" ROOF FRAMING
*1 /4
" P
ER F
OOT M
AX. S
LO
PE
*6 '-0
M
IN
IM
U M
1/2" CHIPBOARD INTERIOR
of NATURAL RESOURCES
MICHIGAN DEPARTMENT PARKS & RECREATION DIVISION
6-11-96 S4DATE: PAGE
VAULT TOILETS
PANELING
PROVIDE 12"x16" VISION-PROOF
METAL GRILL W/ ALUM. INSECT
SCREEN AS APPROVED BY OWNER
*3 '-0
M
IN
IM
U M
*5'-0" MINIMUM
PATTERN 111 SIDING
1/2" BOLT W/NUT & WASHER
TO BE RAM-SET ON SITE
(2 EACH SIDE)
PLAN
(TYP)
4'-0"
(TYP)
2'-0"
NOTE: THE DOOR MAY BE HINGED ON THE LEFT OR
THE RIGHT AND THE PRIVACY SCREEN MAY BE
LOCATED TO THE LEFT OR RIGHT OF THE DOOR
AS LOCAL CONDITIONS DICTATE.
*1 1/4"-1 1/2" OUTSIDE DIA.
1 1/2"
1"x11/4" STOP
1"x11/4" STOP
1 3/4"
*3 '-0
V
TGRAB BARS
*1 '-6
*6
PRIVACY SCREEN DETAILS
FOOTING
CONCRETE
CORNER TRIM (TYP)
1"x4" R.S. CEDAR 1"x3" R.S CEDAR
(TYP)
*1 1/2"
*3'-6" *1'-0"
*PROVIDE BARRIER FREE
ACCESS SIGN FROM
CASTCO. PLACE 60"
ABOVE FINISH FLOOR
TO C OF SIGN.L
(TYP)
SIDING PATTERN 111
2"x4"
1/2" PLYWOOD
#2 SPF
4"x4" POST
2'-0"
CANT STRIP
1 1/2"x45%%D
1" CHAMFER
2"x4"
4"x4" POST
#2 SPF
2'-0"2'-0"
(TYP)
1 1/2" SQ.
WOM EN
THE AMERICANS WITH DISIBILITIES ACT
* DENOTES MINIMUM REQUIREMENTS PER
WOM EN
NOTE:
FASTEN WITH #8x1" LONG, TYPE B, PAN HEAD, ZINC PLATED, THREAD FORMIN
CHIPBOARD
1/2" INTERIOR
5 1/2"
1/
2" 3 1/2"
8'-0"
* DENOTES MINIMUM REQUIREMENTS PER
THE AMERICANS WITH DISIBILITIES ACT
3 1/2"3 1/2" 3"
10"
SECTION 1
7'-8"
1/
4"5 1/
2"
2" 11"11" 11" 11" 11"
NOTE:
LIFTING LUG
(TYP)
AUTOMATIC DOOR CLOSURE
NOTE: PROVIDE SPRIING FOR
DOOR FRAMING
3/
4"
6"8"9" 8" 6" 2"
4"
(TYP)
1/2" PLYWOOD CORE
1/2" SIDING
5' -8
5 11" 2
6 13" 1
7 20" 4
8 63" 1
9 19" 1
ALL BARS WILL BE STRAIGHT
EXCEPT FOR LIFTING LUGS
EACH SIDE OF 2 X 4 X 2 3/4" LONG NAILER.
SECTION 2
1'-0"6" 6" 1'-0"
/4
10" 5'-8"
6" 6"
/4
10"
/2
6' -4
STRAP HINGES
6"
SPRING HINGE
#20660R
STANLEY
4"
CONCRETE FLOOR PLAN
(FROM THE BOTTOM)
ALL STEEL REINFORCEMENT SHALL BE
#3 BARS. PLACE LIFTING LUGS TO FIT
INSIDE VAULT. PLACE (2) GALV. NAILS
NOTES:
2 22
5 5
2" 6"
6"
3'-1"
6"
1' -0
"2
PULL
DOOR
6"
BAR NO. LENGTH NO. REQ'D.
1 92" 7
2 68" 9
3 56" 1
4 39" 2
(TYP)
NAILER
VAULT
2"
11"11" 11"
7'-8"
11" 11"
1' -0
4 4 7 10
6" 6"
2"
9" 8" 6"8" 2"6"
LIFTING LUG
4"
4"
4"4"
4"
3/4"V
T
3' -8
3' -2
6' -0
VAULT TOILETS
MICHIGAN DEPARTMENT PARKS & RECREATION DIVISION
2-01-03 S5of NATURAL RESOURCES DATE: PAGE
NAILER-CAST IN
CONCRETE FLOOR PLAN
1/
2"
1' -5
SLAB
SKYLIGHT DETAIL
TAPER SUPPORT TO
FIT 1 1/2" TO 1/16",
1 1/2" SQ., 48" LONG
1' -2
19" LONG 1" CANT STRIP
SCREW AT 4" ON CENTER. CAULK UNDER
EDGE OF ENTIRE SKYLIGHT AND FRAME.
1'-9"
8 1/4"
*1 '-6
/2
1' -5
1' -4
/2
DOOR OPENING
SLOPE TO DRAIN TO
R
1' -2
4"
4" 4"
4"
4" 2'-0'
1"
CONCRETE SLABGLUE LAMINATED WOOD, AMERICAN INSTITUTE of
PICNIC SHELTER
DATE:of NATURAL RESOURCES
MICHIGAN DEPARTMENT PARKS & RECREATION BUREAU
PAGE 1-15-03 S9
TIMBER CONSTRUCTION CERTIFIED. ALL BEAMS
4'-6"
9"
ENCASEMENT
CONCRETE
24" O.D. MIN.
GRAVEL FILL AS REQUIRED
4" NAILS
STEEL COLUMNS SHALL BE INCLUDED WITH MATERIALS.
ASSEMBLY OF SHELTER. DETAILS FOR ANCHORING
NAILS AND FASTENING DEVICES FOR A TOTAL
FURNISHED WITH ALL NECESSARY NUTS, BOLTS,
PRIMER PAINTED FRAME STRUCTURE SHALL BE
A-36 OF 1/4" PLATE, SHOP FABRICATED AND
COLUMN HARDWARE CONNECTORS: SHALL BE STEEL,
INCLUDE 15# FELT UNDERLAYMENT. BEAM TO
FASCIA, KITS TO BE PROVIDED WITH SHINGLES.
PRESSURE TREATED 2" X 5" PREMIUM GRADE
MATCHED, EDGE V'D ONE SIDE, #2 OR BETTER,
ROOF: 2" X 6" (NOMINAL) KILN DRIED, CENTER
WRAPPED FOR SHIPPING.
SHALL BE FACTORY SEALED AND INDIVIDUALLY
BEYOND THE DRIP EDGE OF THE SHELTER.
EXTEND CONCRETE FLOOR MINIMUM 12"
CONCRETE FLOOR
ACCESSIBLE SURFACE AND
ROUTE CONNECTING WITH SHELTER
COLUMN AVAILABLE)
(OPTIONAL STEEL TUBE
TREATED LAM. COLUMN
EXPANSION JOINT
2'-6"
25' 30'
2'-6" 44'
LAM. CURVED TAPERED BEAM
TREATED FASCIA
TREATED LAM. COLUMN
3:12 ROOF PITCH
COLUMN. BEAMS SHALL BE STRUCTURAL GRADE
COLUMN TO WOOD BEAM CONNECTOR WELDED TO
AND RUST INHIBITED PRIMER, WITH A STEEL
COLUMNS SHALL BE STEEL, A-36, SHOP PAINTED
LIVE LOAD AND 20#/ sq ft WIND LOAD.
DESIGNED AND CERTIFIED TO CARRY 30#/sq ft
BEAM, 3:12 ROOF PITCH. ROOF SHALL BE
30' X 44' (DRIPLINE), GLUE-LAMINATED WOOD
PICNIC SHELTER W/O FLOOR- APROXIMATELY
| 22339 Project Statetmnt +.pdf |
| 22339 Algonac As Built water & Sewer + Shelter |
File details come from the government source that posted it. Updated .