This document contains construction details for vault toilets to be built at a Michigan state park. The Michigan Department of Natural Resources, Parks and Recreation Division is the agency responsible for this project. The document includes detailed plans and specifications for the vault toilets, including dimensions, materials, and construction methods. Key details include the use of a 4'x8'x3'-3" deep concrete vault, 2"x6" backers for grab bars, 2'x4' skylights, 1/2" interior and exterior siding, and a 7:12 roof pitch. The contract opportunity is for the build-out of these vault toilets at the Algonac State Park and Wetzel Recreation Area, located in St. Clair County, Michigan.

The pricing, funding, and contracting details are not included in this document. However, the project appears to be part of targeted ARPA (American Rescue Plan Act) funded improvements for the state parks. Contractors interested in bidding on this work should check for the full solicitation details, including any set-aside requirements, from the Michigan Department of Natural Resources.

Text of this file

2"x6" BACKER FOR GRAB BAR, WITH 3" WALLS of NATURAL RESOURCES

MICHIGAN DEPARTMENT PARKS & RECREATION BUREAU

1-1-03 S1DATE: PAGE

VAULT TOILETS

NOTE: PLACE 12" OF GRANULAR MATERIAL UNDER

SIDE WALL FRAMING

VAULT FOR EVEN SUPPORT

GRILL W/ ALUM.

INSECT SCREEN AS

PROVIDE 12"x16"

SEE DETAIL A

CONCRETE VAULT

4'x8'x3'-3" DEEP

VISION-PROOF METAL

APPROVED BY OWNER

/2

7' -6

*1 '-7

M

IN

USE WATERSTOP SEALANT WHERE TOILET FLOOR

1'-9"

SLAB SEATS ON VAULT

2 GALV. NAILS EACH SIDE

2"x4"x2 3/4" LONG NAILER WITH

SLOPE TO DRAIN

SEE DETAIL B

3'-0 1/2"

F.F.

*36" MAX

PAPER HOLDER

TOILET PAPER

2"x6" BACKER FOR TOILET

HOLDER

LEFT WALL ONLY.

CENTER OF

GRAB BAR

THESE DIMENSIONS ALLOW FULL WIDTH SIDING & INTERIOR PANELS

1'-11 1/4"2'-0"9 3/4"4 1/4" 2'-0"

8'-0"

3 1/2" 7 1/4"

* DENOTES MINIMUM REQUIREMENTS

PER THE AMERICANS WITH DISIBILITIES

ACT

NOTE:

1/

2"

1/

2"

DETAIL A

1"3 1/2"

V E

N T

S P

A C

E

1/

2"

1/

2"

DETAIL B

1" 10"

VAULT TOILETS

BACK WALL FRAMING

PARKS & RECREATION BUREAUMICHIGAN DEPARTMENT

of NATURAL RESOURCES DATE: PAGE1-1-03 S2

FALSE WALL FRAMING

THESE DIMENSIONS ALLOW FULL WIDTH SIDING

2'-0"

5'-5"

F.F.

*1 '-5

2"x6" BACKER FOR GRAB BAR

GRAB BAR

CENTER OF

7' -6

7' -6

THESE DIMENSIONS ALLOW FULL WIDTH INTERIOR PANEL

THIS EDGE ASSEMBLES

TO LEFT WALL

1'-4"1/2" 2'-0" 2'-0" 1/2"

1'-8 1/2" 1'-8 1/2"

SIDING & MARK FOR

5'-5"

FRONT WALL FRAMING

7' -6

INTERIOR PANELING.

DOOR. SAME FOR

DOOR. TRIM & USE

6' -3

THIS PIECE FOR

NOTE: PLACE FULL

WIDTH SHEET OF

1' -3

8 1/2" 5" 3'-2" 8 1/2"5"

5'-5"

RIDGE VENT

8' LONG

CLEAR LEXAN OR

2'x4' SKYLIGHT

LAYERS OF SHINGLES

SKYLIGHT UNDER TWO

PLACE TOP EDGE OF

1/2" PLYWOOD

SEE DETAILS PG. M13

1'-0"

RAFTER FRAMING & DETAILS

*1 /4

" P

ER

F O

O T

M A

X . S

LO

P

E

PARKS & RECREATION DIVISION

1-1-03 S3

MICHIGAN DEPARTMENT

of NATURAL RESOURCES DATE: PAGE

1/2" SIDING

ROOF PLAN2"x4" BRACING

& NAILER (TYP)

2'x4' SKYLIGHT

V E

N T

O P

E N

I N

G

PANELING

1/2" INTERIOR

2'x4' SKYLIGHT

2' -1

/2

30%%d

4'-3"

1'-8"

1'-8"

#2 SPF (TYP)

2"x4" ROOF FRAMING

TRIM

INTERIOR ELEVATION 1"x6" CEDAR

DRIP EDGE

EQUIV.

ANCHOR

2"x4" FRAMING

PANELING

1/2" INTERIOR

EXTERIOR ELEVATION

1/2" EXTERIOR SIDING

PATTERN 111

PRIVACY SCREEN-

VAULT TOILETS

NOTE:

* DENOTES MINIMUM REQUIREMENTS

PER THE AMERICANS WITH DISIBILITIES

CEDAR TRIM ACT

DRIP EDGE

ROOF SECTION1/2" SIDING

SKYLIGHT

ROOFING FELT

8' LONG RIDGE VENT

3x1 BLACK SHINGLES

1/2" CDX PLYWOOD

2"x4" BRACING

& NAILER

1 1/2"

10"

*3 '-0

M

IN

IM

U M

ALLOWS AIR FLOW AT RIDGE VENT

2'-0"2'-0" 2'-0"

ROOF SECTION

1'-0"2'-0"

2"x4" FRAMING

PANELING

1/2' INTERIOR

ANCHOR

RAFTER FRAMING & DETAILS

3x1 BLACK SHINGLES

2"x4" BRACING & NAILER

#2 SPF (TYP)

V

E

N

T

2"x4" ROOF FRAMING

*1 /4

" P

ER F

OOT M

AX. S

LO

PE

*6 '-0

M

IN

IM

U M

1/2" CHIPBOARD INTERIOR

of NATURAL RESOURCES

MICHIGAN DEPARTMENT PARKS & RECREATION DIVISION

6-11-96 S4DATE: PAGE

VAULT TOILETS

PANELING

PROVIDE 12"x16" VISION-PROOF

METAL GRILL W/ ALUM. INSECT

SCREEN AS APPROVED BY OWNER

*3 '-0

M

IN

IM

U M

*5'-0" MINIMUM

PATTERN 111 SIDING

1/2" BOLT W/NUT & WASHER

TO BE RAM-SET ON SITE

(2 EACH SIDE)

PLAN

(TYP)

4'-0"

(TYP)

2'-0"

NOTE: THE DOOR MAY BE HINGED ON THE LEFT OR

THE RIGHT AND THE PRIVACY SCREEN MAY BE

LOCATED TO THE LEFT OR RIGHT OF THE DOOR

AS LOCAL CONDITIONS DICTATE.

*1 1/4"-1 1/2" OUTSIDE DIA.

1 1/2"

1"x11/4" STOP

1"x11/4" STOP

1 3/4"

*3 '-0

V

TGRAB BARS

*1 '-6

*6

PRIVACY SCREEN DETAILS

FOOTING

CONCRETE

CORNER TRIM (TYP)

1"x4" R.S. CEDAR 1"x3" R.S CEDAR

(TYP)

*1 1/2"

*3'-6" *1'-0"

*PROVIDE BARRIER FREE

ACCESS SIGN FROM

CASTCO. PLACE 60"

ABOVE FINISH FLOOR

TO C OF SIGN.L

(TYP)

SIDING PATTERN 111

2"x4"

1/2" PLYWOOD

#2 SPF

4"x4" POST

2'-0"

CANT STRIP

1 1/2"x45%%D

1" CHAMFER

2"x4"

4"x4" POST

#2 SPF

2'-0"2'-0"

(TYP)

1 1/2" SQ.

WOM EN

THE AMERICANS WITH DISIBILITIES ACT

* DENOTES MINIMUM REQUIREMENTS PER

WOM EN

NOTE:

FASTEN WITH #8x1" LONG, TYPE B, PAN HEAD, ZINC PLATED, THREAD FORMIN

CHIPBOARD

1/2" INTERIOR

5 1/2"

1/

2" 3 1/2"

8'-0"

* DENOTES MINIMUM REQUIREMENTS PER

THE AMERICANS WITH DISIBILITIES ACT

3 1/2"3 1/2" 3"

10"

SECTION 1

7'-8"

1/

4"5 1/

2"

2" 11"11" 11" 11" 11"

NOTE:

LIFTING LUG

(TYP)

AUTOMATIC DOOR CLOSURE

NOTE: PROVIDE SPRIING FOR

DOOR FRAMING

3/

4"

6"8"9" 8" 6" 2"

4"

(TYP)

1/2" PLYWOOD CORE

1/2" SIDING

5' -8

5 11" 2

6 13" 1

7 20" 4

8 63" 1

9 19" 1

ALL BARS WILL BE STRAIGHT

EXCEPT FOR LIFTING LUGS

EACH SIDE OF 2 X 4 X 2 3/4" LONG NAILER.

SECTION 2

1'-0"6" 6" 1'-0"

/4

10" 5'-8"

6" 6"

/4

10"

/2

6' -4

STRAP HINGES

6"

SPRING HINGE

#20660R

STANLEY

4"

CONCRETE FLOOR PLAN

(FROM THE BOTTOM)

ALL STEEL REINFORCEMENT SHALL BE

#3 BARS. PLACE LIFTING LUGS TO FIT

INSIDE VAULT. PLACE (2) GALV. NAILS

NOTES:

2 22

5 5

2" 6"

6"

3'-1"

6"

1' -0

"2

PULL

DOOR

6"

BAR NO. LENGTH NO. REQ'D.

1 92" 7

2 68" 9

3 56" 1

4 39" 2

(TYP)

NAILER

VAULT

2"

11"11" 11"

7'-8"

11" 11"

1' -0

4 4 7 10

6" 6"

2"

9" 8" 6"8" 2"6"

LIFTING LUG

4"

4"

4"4"

4"

3/4"V

T

3' -8

3' -2

6' -0

VAULT TOILETS

MICHIGAN DEPARTMENT PARKS & RECREATION DIVISION

2-01-03 S5of NATURAL RESOURCES DATE: PAGE

NAILER-CAST IN

CONCRETE FLOOR PLAN

1/

2"

1' -5

SLAB

SKYLIGHT DETAIL

TAPER SUPPORT TO

FIT 1 1/2" TO 1/16",

1 1/2" SQ., 48" LONG

1' -2

19" LONG 1" CANT STRIP

SCREW AT 4" ON CENTER. CAULK UNDER

EDGE OF ENTIRE SKYLIGHT AND FRAME.

1'-9"

8 1/4"

*1 '-6

/2

1' -5

1' -4

/2

DOOR OPENING

SLOPE TO DRAIN TO

R

1' -2

4"

4" 4"

4"

4" 2'-0'

1"

CONCRETE SLABGLUE LAMINATED WOOD, AMERICAN INSTITUTE of

PICNIC SHELTER

DATE:of NATURAL RESOURCES

MICHIGAN DEPARTMENT PARKS & RECREATION BUREAU

PAGE 1-15-03 S9

TIMBER CONSTRUCTION CERTIFIED. ALL BEAMS

4'-6"

9"

ENCASEMENT

CONCRETE

24" O.D. MIN.

GRAVEL FILL AS REQUIRED

4" NAILS

STEEL COLUMNS SHALL BE INCLUDED WITH MATERIALS.

ASSEMBLY OF SHELTER. DETAILS FOR ANCHORING

NAILS AND FASTENING DEVICES FOR A TOTAL

FURNISHED WITH ALL NECESSARY NUTS, BOLTS,

PRIMER PAINTED FRAME STRUCTURE SHALL BE

A-36 OF 1/4" PLATE, SHOP FABRICATED AND

COLUMN HARDWARE CONNECTORS: SHALL BE STEEL,

INCLUDE 15# FELT UNDERLAYMENT. BEAM TO

FASCIA, KITS TO BE PROVIDED WITH SHINGLES.

PRESSURE TREATED 2" X 5" PREMIUM GRADE

MATCHED, EDGE V'D ONE SIDE, #2 OR BETTER,

ROOF: 2" X 6" (NOMINAL) KILN DRIED, CENTER

WRAPPED FOR SHIPPING.

SHALL BE FACTORY SEALED AND INDIVIDUALLY

BEYOND THE DRIP EDGE OF THE SHELTER.

EXTEND CONCRETE FLOOR MINIMUM 12"

CONCRETE FLOOR

ACCESSIBLE SURFACE AND

ROUTE CONNECTING WITH SHELTER

COLUMN AVAILABLE)

(OPTIONAL STEEL TUBE

TREATED LAM. COLUMN

EXPANSION JOINT

2'-6"

25' 30'

2'-6" 44'

LAM. CURVED TAPERED BEAM

TREATED FASCIA

TREATED LAM. COLUMN

3:12 ROOF PITCH

COLUMN. BEAMS SHALL BE STRUCTURAL GRADE

COLUMN TO WOOD BEAM CONNECTOR WELDED TO

AND RUST INHIBITED PRIMER, WITH A STEEL

COLUMNS SHALL BE STEEL, A-36, SHOP PAINTED

LIVE LOAD AND 20#/ sq ft WIND LOAD.

DESIGNED AND CERTIFIED TO CARRY 30#/sq ft

BEAM, 3:12 ROOF PITCH. ROOF SHALL BE

30' X 44' (DRIPLINE), GLUE-LAMINATED WOOD

PICNIC SHELTER W/O FLOOR- APROXIMATELY

Other files

File Type Posted
Addendum 2 22339.pdf PDF
Project Statement 22339.pdf PDF
RFP Billable Rate 22339.pdf PDF
SAMPLE Billable Rate Contract (Rev 220207).pdf PDF
Addendum 1 22339.pdf PDF
Addendum 3 22339.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .