Project 655-23-201 - Brand Name Justification Hilti Firestop.pdf

PDF 135 KB Posted

Attached to
655-23-201 Energy Center Hot Water Heater
Solicitation number
36C25025B0030
Issued by

About this file

This document is a Justification and Approval (J&A) for Other Than Full and Open Competition, specifically a Brand Name Only Justification for the Department of Veterans Affairs, VISN 10, 655 Saginaw VA Medical Center. The justification is for the installation of a HILTI Firestop System for Project No. 655-23-201 Energy Center Water Heater Replacement. The VA is seeking to standardize the medical center's firestopping system due to Joint Commission safety inspection incidents, as recommended by the VA Fire Safety Committee. The justification cites statutory authority under 41 USC §3304(a)(1) for using only one responsible source, arguing that the HILTI system is the only compatible firestopping product and mixing of firestopping materials is not allowed per Joint Commission documentation.

The document includes a requirements certification by Calvin Hugo, Asst. Chief of FMS at the Saginaw VAMC, and a contracting officer certification by Kyle Lipper. The justification emphasizes that utilizing only the HILTI Firestop System will help avoid potential Joint Commission accreditation issues by allowing inspectors to recognize one brand of firestopping and maintain a single inventory of Material Safety Data Sheets (MSDS) for UL certification verification. The document is part of the procurement process for the water heater replacement project, which involves standardizing and improving the facility's fire safety systems.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 3

Justification and Approval (J&A)

For Other Than Full and Open Competition

Brand Name Only Justification

This form must be provided for each brand name only item required by the construction specifications. If the project has multiple brand name only items a separate form is required for each one.

Acquisition Plan Action ID: VA 25 00067604 2237: 655 25 3 6132 0220

1. Contracting Activity: Department of Veterans Affairs, VISN 10, 655 Saginaw VA Medical Center

2. Nature and/or Description of the Action Being Processed:

Project No. 655 23 201 Energy Center Water Heater Replacement

3. Description of Supplies/Services Required to Meet the Agency�s Needs:

Installation of HILTI Firestop System to standardize medical center�s firestopping system due to Joint Commission safety inspection incidents as recommended by VA Fire Safety Committee from the Office of Construction & Facilities Management Service in Washington, DC to correct long term inspection issues.

Specification section(s) where the brand name only item is listed: 07 84 00 Firestopping

4. Statutory Authority Permitting Other than Full and Open Competition:

(X) (1) Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements per 41 USC §3304(a)(1) as implemented by FAR 6.302 1;

( ) (2) Unusual and Compelling Urgency per 41 USC §3304(a)(2) as implemented by FAR 6.302 2;

( ) (3) Industrial Mobilization, Engineering, Developmental or Research Capability or Expert Services per 41 USC §3304(a)(3) as implemented by FAR 6.302 3;

( ) (4) International Agreement per 41 USC §3304(a)(4) as implemented by FAR 6.302 4 ( ) (5) Authorized or Required by Statute per 41 USC §3304(a)(5) as implemented by FAR 6.302 5;

( ) (6) National Security per 41 USC §3304(a)(6) as implemented by FAR 6.302 6;

( ) (7) Public Interest per 41 USC §3304(a)(7) as implemented by FAR 6.302 7;

5. Demonstration that the Contractor�s Unique Qualifications or Nature of the Acquisition Requires the Use of the Authority Cited Above (applicability of authority):

The Saginaw VAMC has utilized only the HILTI Firestop System to standardize the system at the medical center in an effort to avoid potential issues with Joint Commission accreditation by eliminating the use of various brands of firestop materials. Utilization of one system affords Joint Commission life safety inspectors the opportunity to recognize one brand of firestopping and allows for an inventory of MSDS sheets for one product for verification of UL certification, etc. The only product compatible with Hilti firestopping per attached documentation is Hilti. Mixing of firestopping is not allowed per the documentation from Joint Commission, which would require partial demolition of walls to remove old fireproofing if not Hilti. Hilti has a listed UL program that can determine firestopping requirements from the construction barrier.

6. Requirements Certification: I certify that the requirement outlined in this justification is a Bona Fide Need of the Department of Veterans Affairs and that the supporting data under my cognizance, which are included in the justification, are accurate and complete to the best of my knowledge and belief.

(This signature is the requestor�s supervisor, chief of service, someone with responsibility and accountability)

Name: Calvin Hugo Date Title: Asst. Chief of FMS Facility: 655 Saginaw VAMC

CONTRACTING ONLY BELOW

7. Approvals in accordance with the VHAPM Part 806.3 OFOC SOP: This part if filled out by

Contracting Staff as part of the Justification

a. Contracting Officer or Designee�s Certification (required): I certify that the foregoing justification is accurate and complete to the best of my knowledge and belief.

Name Date Title Facility