About this file
This is a preliminary job sketch for Portland General Electric Company (PGE) prepared for Clackamas County Service District #5 in connection with the Pilkington Road at SW Dawn Street Enhanced Crossing Project (Job #11-26). The project involves installation of underground electrical circuit infrastructure, one new 25-foot aluminum streetlight pole with a new 4-foot mast arm on a concrete base set one foot behind the sidewalk with an 88-watt LED Leotek Green Cobra Gray light fixture connected at 240 volts, and replacement of an existing LED light fixture on an existing pole at the intersection of Meridian-Pilkington Road and SW Dawn Street in Wilsonville, Oregon. The work is located in Clackamas County and will be performed at 19053 Pilkington Road, Rivergrove, Oregon. The project documentation indicates this is a single-sheet design plan with the job number M5952300.
The sketch includes standard PGE construction checklist requirements covering utility locates, staking, flagging, permits, tree trimming, easement documentation, customer notifications, and traffic planning. Per Oregon law, the contractor must call the Oregon Utility Notification Center at 811 at least two business days prior to excavation to request utility locates. The project contact is Rico Torres Solis, reachable at 503.403.9084. The document serves as an as-built verification and NESC violations correction record and requires completion of foreman sign-off, engineering review, and designer as-built verification before project closure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 300325560_Specifications_Bid.pdf | ||
| BID 2026-62 Pilkington.pdf | ||
| 300325560_Plans_Bid.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 1x17
FIRST!
SAFETY
THINK
2 BUSINESS DAYS PRIOR TO EXCAVATION.
UTILITY NOTIFICATION CENTER, 811 AT LEAST
TO REQUEST UTILITY LOCATES CALL THE OREGON
Know what’sbelow.
Callbefore youdig.
NOTIFICATION CENTER ADMINISTRATION @ (503-232-1987)
THE RULES BY CALLING THE OREGON UTILITY
THROUGH 952-001-0090. YOU MAY OBTAIN COPIES OF
THOSE RULES ARE SET FORTH IN OAR 952-001-0010
BY THE OREGON UTILITY NOTIFICATION CENTER.
OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED
ATTENTION:
CALL 811 BEFORE YOU DIG
Date:
Date:
Foreman:
AS-BUILT VERIFICATION & NESC VIOLATIONS CORRECTED
GF:
SDPM/ENG REVIEW: ASBUILT BY DESIGNER:
TITLE
LOCATION
SECTION(S) SHEET
SIZE
c PORTLAND GENERAL ELECTRIC CO. - ALL RIGHTS RESERVED
WORK WITH
DESIGN BY DRAWN BYPHONE (503)
CIRCUIT
DESCRIPTION
JOB NO.ACCOUNT: AWO:
COUNTY
SCALE:DATE: N/A
This document accurately represents FIELD construction.
LINE CREW CENTER
PGE
WR CHECKLIST
ITEM
LOCATES
STAKING
FLAGGING
PERMITS
YES
CUTSHEET
TREETRIM
EASEMENT
COMPANY
DOOR HANGER
PH#
DATE
LANDSCAPE
CUSTOMER
SHUTDOWN
SHUTDOWN
TRANSMISSION
COMMENT
CONTACT
TIME
C#
HOLEDIGGER
BOOM
BACKHOE
PGE TRENCH
UG CIR. VER.
TRAFFIC PLAN
e00225 Typewritten Text
CONSTRUCTION
e00225 Typewritten Text e00225 Typewritten Text e00225 Typewritten Text
E72429 Typewritten Text
THINK
SAFETY
FIRST!
E62194 Image
E62194 Image
E62194 Image
E62194 Image
E62194 Image
E62194 Image
E62194 Text Box
INSTALL 88W LED LEOTEK GREEN COBRA GRAY LIGHT
ON NEW STREETLIGHT ONLY 25' ALUMINUM POLE
USE NEW 4' MAST ARM
ON 5CL-LB-PGE CONCRETE BASE
SET 1' BEHIND SIDEWALK
CONNECT 240V
E62194 Image
E62194 Text Box
REPLACE EXISTING LED LIGHT WITH
88W LED LEOTEK GREEN COBRA GRAY LIGHT
ON EXISTING POLE
USE EXISTING MAST ARM
CONNECT 240V
E62194 Image
E62194 Image
| DMPGE V8 PRESET BORDERS |
| References |
| Original, DMPGE V8 PRESET BORDERS.DGN, Original Model |
| Combo Box1: [WILSONVILLE] |
| Combo Box2: [9480 SW BOECKMAN RD] |
| Combo Box3: [WILSONVILLE, OR 97070] |
| Text7: 8.7.26 |
| Text8: 1070001 |
| Text9: 1000009106 |
| Text10: M5952300 |
| Text11: Clackamas County Service Dist. # 5 / SW Dawn St & Pilkington Rd Enhanced Crossing Project/Job #11-26 |
| Text12: MERIDIAN-PILKINGTON |
| Text13: 19053 Pilkington Rd, Rivergrove OR |
| TexT14: Install UG circuit, 1 Aluminum pole & LED Light and replace 1 light on existing pole, connect @240V |
| Text15: CLACKAMAS |
| Text16: |
| Text17: |
| Text18: rico Torres Solis |
| Text19: 503.403.9084 |
| Text20: rico Torres Solis |