This is a preliminary job sketch for Portland General Electric Company (PGE) prepared for Clackamas County Service District #5 in connection with the Pilkington Road at SW Dawn Street Enhanced Crossing Project (Job #11-26). The project involves installation of underground electrical circuit infrastructure, one new 25-foot aluminum streetlight pole with a new 4-foot mast arm on a concrete base set one foot behind the sidewalk with an 88-watt LED Leotek Green Cobra Gray light fixture connected at 240 volts, and replacement of an existing LED light fixture on an existing pole at the intersection of Meridian-Pilkington Road and SW Dawn Street in Wilsonville, Oregon. The work is located in Clackamas County and will be performed at 19053 Pilkington Road, Rivergrove, Oregon. The project documentation indicates this is a single-sheet design plan with the job number M5952300.

The sketch includes standard PGE construction checklist requirements covering utility locates, staking, flagging, permits, tree trimming, easement documentation, customer notifications, and traffic planning. Per Oregon law, the contractor must call the Oregon Utility Notification Center at 811 at least two business days prior to excavation to request utility locates. The project contact is Rico Torres Solis, reachable at 503.403.9084. The document serves as an as-built verification and NESC violations correction record and requires completion of foreman sign-off, engineering review, and designer as-built verification before project closure.

View the file

Other files

File Type Posted
300325560_Specifications_Bid.pdf PDF
BID 2026-62 Pilkington.pdf PDF
300325560_Plans_Bid.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1 1x17

FIRST!

SAFETY

THINK

2 BUSINESS DAYS PRIOR TO EXCAVATION.

UTILITY NOTIFICATION CENTER, 811 AT LEAST

TO REQUEST UTILITY LOCATES CALL THE OREGON

Know what’sbelow.

Callbefore youdig.

NOTIFICATION CENTER ADMINISTRATION @ (503-232-1987)

THE RULES BY CALLING THE OREGON UTILITY

THROUGH 952-001-0090. YOU MAY OBTAIN COPIES OF

THOSE RULES ARE SET FORTH IN OAR 952-001-0010

BY THE OREGON UTILITY NOTIFICATION CENTER.

OREGON LAW REQUIRES YOU TO FOLLOW RULES ADOPTED

ATTENTION:

CALL 811 BEFORE YOU DIG

Date:

Date:

Foreman:

AS-BUILT VERIFICATION & NESC VIOLATIONS CORRECTED

GF:

SDPM/ENG REVIEW: ASBUILT BY DESIGNER:

TITLE

LOCATION

SECTION(S) SHEET

SIZE

c PORTLAND GENERAL ELECTRIC CO. - ALL RIGHTS RESERVED

WORK WITH

DESIGN BY DRAWN BYPHONE (503)

CIRCUIT

DESCRIPTION

JOB NO.ACCOUNT: AWO:

COUNTY

SCALE:DATE: N/A

This document accurately represents FIELD construction.

LINE CREW CENTER

PGE

WR CHECKLIST

ITEM

LOCATES

STAKING

FLAGGING

PERMITS

YES

CUTSHEET

TREETRIM

EASEMENT

COMPANY

DOOR HANGER

PH#

DATE

LANDSCAPE

CUSTOMER

SHUTDOWN

SHUTDOWN

TRANSMISSION

COMMENT

CONTACT

TIME

C#

HOLEDIGGER

BOOM

BACKHOE

PGE TRENCH

UG CIR. VER.

TRAFFIC PLAN

e00225 Typewritten Text

CONSTRUCTION

e00225 Typewritten Text e00225 Typewritten Text e00225 Typewritten Text

E72429 Typewritten Text

THINK

SAFETY

FIRST!

E62194 Image

E62194 Image

E62194 Image

E62194 Image

E62194 Image

E62194 Image

E62194 Text Box

INSTALL 88W LED LEOTEK GREEN COBRA GRAY LIGHT

ON NEW STREETLIGHT ONLY 25' ALUMINUM POLE

USE NEW 4' MAST ARM

ON 5CL-LB-PGE CONCRETE BASE

SET 1' BEHIND SIDEWALK

CONNECT 240V

E62194 Image

E62194 Text Box

REPLACE EXISTING LED LIGHT WITH

88W LED LEOTEK GREEN COBRA GRAY LIGHT

ON EXISTING POLE

USE EXISTING MAST ARM

CONNECT 240V

E62194 Image

E62194 Image

DMPGE V8 PRESET BORDERS
References
Original, DMPGE V8 PRESET BORDERS.DGN, Original Model
Combo Box1: [WILSONVILLE]
Combo Box2: [9480 SW BOECKMAN RD]
Combo Box3: [WILSONVILLE, OR 97070]
Text7: 8.7.26
Text8: 1070001
Text9: 1000009106
Text10: M5952300
Text11: Clackamas County Service Dist. # 5 / SW Dawn St & Pilkington Rd Enhanced Crossing Project/Job #11-26
Text12: MERIDIAN-PILKINGTON
Text13: 19053 Pilkington Rd, Rivergrove OR
TexT14: Install UG circuit, 1 Aluminum pole & LED Light and replace 1 light on existing pole, connect @240V
Text15: CLACKAMAS
Text16:
Text17:
Text18: rico Torres Solis
Text19: 503.403.9084
Text20: rico Torres Solis

File details come from the government source that posted it. Updated .