300325560_Plans_Bid.pdf
PDF 6 MB Posted
- Solicitation number
- S-C01010-00017772
- Issued by
- Oregon
About this file
This is a set of project plans and bid documents for the SW Pilkington Road at SW Dawn Street Enhanced Crossing project in Clackamas County, Oregon. The project is a roadway improvement initiative involving grading, drainage, roadside development, signing, pavement markings, signals, and illumination work at the intersection of SW Pilkington Road and SW Dawn Street in Oregon City. The scope includes construction of curb ramps with ADA-compliant features, installation of a rapid flashing beacon (RRFB) system with pedestrian signals, pavement markings including staggered continental crosswalks, new street lighting, utility relocations, erosion and sediment control measures, and associated infrastructure improvements. The plans encompass multiple sheets detailing curb ramp details, general construction specifications, RRFB and illumination plans, signing and striping layouts, and grading and erosion control measures. The project is designed by Kittelson & Associates, Inc. under the direction of registered professional engineer Sara Parks, with Clackamas County serving as the project owner and contact through Michael Oleson, P.E.
The plans are dated March 9, 2021, with final digital signatures dated June 24, 2026. Construction details reference the 2024 Oregon Standard Specifications for Construction and require coordination with multiple utility providers including Portland General Electric for power service (Work Orders M5952294 and M5952300), Clackamas River Water, Northwest Natural Gas, Ziply Communications, and Comcast. Contractor responsibilities include field verification of ADA compliance for ramp construction, coordination with Portland General Electric a minimum of four weeks before commencing infrastructure work, and scheduling post-construction inspections with Clackamas County. All materials and workmanship must conform to National Electrical Code standards, NEMA requirements, and Underwriters Laboratories specifications. The contractor must maintain concrete structures free from traffic for at least seven calendar days following construction and notify Clackamas County upon completion for final inspection.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 300325560_Specifications_Bid.pdf | ||
| BID 2026-62 Pilkington.pdf | ||
| PrelimJobSketch-M5952300.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SW DAWN STSW
P
IL
KI
NG
TO
N
RD
SW CHILDS RD
LAK
EVI
EW
BL
VD
SW MCEWAN RD
RED LEAF ST
CENTERWOOD ST
KENNY ST
SW
5T H
AV
E
JEAN RD
LOWER BOONES
FER
RY R
D
CLACKAMAS COUNTY
CLACKAMAS COUNTY
OREGON TI
TL
E
SH
EE
T
99E
SITE
DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT
SW PILKINGTON ROAD AT SW DAWN STREET ENHANCED CROSSING PROJECT
VICINITY MAP
SCALE: 1" = 1500'
PLANS FOR GRADING, DRAINAGE, ROADSIDE DEVELOPMENT, SIGNING, PAVEMENT MARKINGS, SIGNALS, ILLUMINATION
CLACKAMAS COUNTY
OREGON
Project Location
SEC. 29 T.1S. R.2E.
CLACKAMAS
COUNTY
UTILITY NOTIFICATION:
ATTENTION: Oregon Law Requires You To Follow Rules Adopted By The Oregon Utility Notification Center. Those Rules Are Set Forth In OAR 952-001-0010 Through 952-001-0090. You May Obtain Copies Of The Rules By Calling The Center. (Note: The Telephone Number For The Oregon Utility Notification Center Is (503) 232-1987.)
PROJECT CONTACTS
OWNER
CLACKAMAS COUNTY
CONTACT: Michael Oleson, P.E.
ADDRESS: 150 Beavercreek Rd
Oregon City, OR, 97045
PHONE: 503.742.4658
EMAIL: MichaelOle@clackamas.us
SURVEYOR
CLACKAMAS COUNTY
CONTACT: Brian Paull ADDRESS: 150 Beavercreek Rd
Oregon City, OR, 97045
PHONE: 503.742.4475
EMAIL: bpaull@clackamas.us
ENGINEER
KITTELSON & ASSOCIATES, INC.
CONTACT: Sara Parks, P.E.
ADDRESS: 851 SW 6th Avenue, Suite 600
Portland, OR 97204
PHONE: 503.535.7464
EMAIL: sparks@kittelson.com
INDEX OF SHEETS
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ A-
TI
TL
ES
HE
ET
-3
.d w g Pl ot S ta m p:
/2 4/
:4
6:
A M
Er ic Ge rm un ds on
A01
Curb Ramp DetailsBC01 Thru BC02
General ConstructionC01
Erosion & Sediment ControlFB01
RRFB & Illumination PlanMB01
MA01
RRFB & Illumination DetailsMC01-MC02
RRFB & Illumination Legend
QA01 Signing and Striping Plan and Legend
QA02 Signing Details and Sign and Post Data Table
QA03 Signing Details
A01 Titlesheet Legend and AbbreviationsA02
Roadway DetailsBB01
LE
GE
ND
A
ND
A
BB
RE
VI
AT
IO
NS
A02
Drawing
Sta. Station
Catch Basin Curb Inlet
Area Drain
Sht. Sheet
R/W Rt. Right
R Radius
Delta Angle
PT Point of Tangency
PVI Point of Vertical InflectionEdge of Asphalt Concrete
Asphalt Concrete
PVC Poly Vinyl Chloride
Ductile Iron
Begin Vertical Curve
Elevation
FT Feet
American Disabilities Act
S Slope
Each
RCP Reinforced Concrete Pipe
WES Water Environmental Services
Electrical
T Telecom
SD Storm Drain
WQ Water Quality
Composite
Thkn. Thickness
WQMH Water Quality Manhole
PRC Point of Reverse Curvature
Bottom of Curb at Face
Back of Sidewalk
ODOT Oregon Department of Transportation
Lt. Left
Length
PC Point of Curvature PCC Point of Compound Curvature
PI Point of Inflection
NO. Number
LF Linear Feet
IE Invert Elevation
G Gas GV Gas Valve
LVC Length of Vertical Curve
ACP Asphalt Concrete Pavement NOM. Nominal N.T.S./NTS Not to Scale
MJ Mechanical Joint
Max. Maximum
PE Plain End
F.T. Flat Top
VC Vertical Curve
Min. Minimum
PUE Public Utility Easement
PSUE Public Slope & Utility Easement
PSE Public Slope Easement
End Vertical Curve Existing
Flange Flow Line
DWG.
CB
CI
AD
Δ
EAC
AC
DI
BVC
ELEV
ADA
EA
COMP.
BC
BW
EVC
Extg.
FLG
F.L./FL
Permanent Right Of Way Easement
Proposed Storm Sewer Pipe
Existing Gas Meter
Existing Water Meter
Existing Fire Hydrant Existing Water Valve
Existing Storm Curb Inlet
Existing Sanitary Manhole
Existing Storm Manhole
Existing Storm Sewer Line
Existing NW Natural Gas Line
Existing Sanitary Line
Existing Fence Line
Existing Street Light
Existing Utility Pole Existing Guy To Utility Pole
Existing Gas Valve
Existing Sign Existing Mail Box
Existing Telephone Junction Box (Riser)
T T T
G G G
X X X X X
Proposed Sawcut Line
Proposed Storm Manhole
Proposed Storm Inlet
Existing Minor Contour
Existing Major Contour
Proposed Minor Contour Proposed Major Contour
Proposed Sidewalk
GV
Proposed Utility Pole Mounted Street Light
Proposed Pedestrian Signal Pole
Proposed Junction Box
Existing Underground Traffic Signal Lines
Existing WaterlineW W W
Existing Overhead WiresOHW OHW
Existing Underground Power LinesOHW OHW
T Existing Telephone Manhole
Existing Signal Controller Cabinet Existing Signal Junction Box
Existing Telephone Line
FO FO Existing Fiber Optic Line
Proposed Curb/Gutter
F F F F F F F Proposed Grading Daylight - Fill
Existing Sanitary Force Main Line
Proposed Conduit
Variable Depth Grind and 4" Inlay
Existing Survey Monument
MH Manhole
TC Top of Curb at Face
Proposed Grading Daylight - CutC C C C C C
TRK Truck
OSSC 2021 Oregon Standard Specifications for Construction
Len
ABBREVIATIONS
LEGEND
Elec
Proposed Permanent Right Of Way Easement
TCE Temporary Construction Easement
Full Depth ACP Repair
Bark Mulch Installation
ACP Driveway Repair
Concrete Driveway Repair
Existing Cable TV LineCTV CTV
S D
Temporary Construction EasementTCE TCE
PSE PSE
Proposed Public Slope and Utility EasementPSUE PSUE
Proposed Public Utility EasementPUE PUE
UTILITY CONTACTS
NATURAL GAS
NW Natural (NWN) CONTACT: Ryan Winfree ADDRESS: 220 NW Second Ave
Portland, OR 97209
PHONE: 971.378.2448
EMAIL: NWNSherwoodEngineering@nwnatural.com
COMMUNICATIONS
Comcast CONTACT: Matt Bravo ADDRESS: 11308 SW 68th Parkway
Tigard, OR 977223
Water Environmental Services (WES) CONTACT: Don Kemp
ADDRESS:
PHONE: 503-742-4577
EMAIL: donkem@clackamas.us
COMMUNICATIONS
Ziply CONTACT: Rui Wu ADDRESS: 4155 SW Cedar Hills Blvd
Beaverton, OR 97005
PHONE: 971.990.7269
EMAIL: rui.wu1@ziply.com
Existing Tree Removal
Proposed Slope Easement
W Water
Permanent Right-of-Way Easement
Existing Deciduous/Coniferous Tree
Remove/Abandon Existing Pipe
Existing Berm Top of Bank
Existing Permanent Easement Existing Property Line
ELECTRIC (ILLUMINATION)
Portland General Electric (M5952300)
CONTACT:
ADDRESS:
PHONE:
EMAIL:
Portland General Electric (M5952294)
CONTACT:
ADDRESS:
PHONE:
EMAIL:
WATER
Clackamas River Water (CRW) CONTACT: Joe Eskew ADDRESS: 16770 SE 82nd Drive
Clackamas, OR 97015
PHONE: 503.747.8520
EMAIL: jeskew@crwater.com
Rico Solis
Rodrigo.Solis@pgn.com
Eric Parker
503.806.3556 eric.parker@pgn.com
SANITARY & STORM SEWER
D
ELECTRIC
Proposed Mailbox
Permanent Seeding Installation
121 SW Salmon St Portland, Oregon, 97204 503.403.9084
150 Beavercreek Road #430 Oregon City, OR 97045
Accompanied by WES Dwg.:
SWM-14, SWM-18, 4-9, 4-24
Accompanied by Clackamas County Dwg.:
C100, D650, D675, R100, S100, S150, S960, T100, T130, T150, T250, T400
Accompanied by Oregon Standard Dwg.:
RD363, RD700, RD722, RD900, RD902, RD904,
RD910, RD920, RD960, TM457, TM467,
TM470, TM482, TM485, TM500, TM503,
TM671, TM676, TM681, TM687, TM688,
TM700, TM701, TM702
TBC Top of Curb at Back
CubicCU
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ A-
TI
TL
ES
HE
ET
-3
.d w g Pl ot S ta m p:
/2 4/
:4
6:
A M
Er ic Ge rm un ds on
121 SW Salmon St Portland, Oregon, 97204
PHONE: 503.351.9331
EMAIL: matthew_bravo@comcast.com
Grouted riprap
STANDARD DRAWINGS
Digitally Signed 2026.06.24
BB01Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\
BC
-C
UR
B
RA
M P
DE
TA
IL
S-
8.
dw g Pl ot S ta m p:
/2 4/
:4
7:
A M
Er ic Ge rm un ds on
EN
G I NEER
OREGON
AL
ION
SSPROFEREDSTEIGRE
RENEWS:06/30/2027
90732PE
ER IC EDW A R D GERMUNDSO
N
M A Y 14 , 2 0 19
RO
AD
W
AY
D
ET
AI
LS
Width Varies (2' min)
Varies Wet pour grout Nom. Thkn. - 4"
(See note 2)
4" - 6" rounded rocks embedded, (See note 2)
Sidewalk finished grade elevation (Typ.)
Curb & Gutter 1" (min.) rock exposure above curb (2" max.)
NOTES
1. See General Construction Plans and Curb Ramp Details for intended locations of grouted round rock.
2. For grouted round rock, after removal of forms from curbs and sidewalks, pour grout to the depths specified in sections. While grout is still wet take individual 4"-6" round non-angular rocks and press into the wet grout to the exposure depths shown. Wet grout will raise to an indeterminate height not to exceed the finished grade surface shown.
3. For grouted round rock, place round rocks at random spacing without any continuous open gaps greater than 1".
Riprap geotextile
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C C
C
C
C
C
C
C
C
C
C
FL:(99.09)
TC:(98.73)
FL:(98.66)
(99.74)
(99.19)
TC:(99.60)
FL:98.90
FL:98.83
TC:98.90
TC:98.83
TC:99.01
99.11
98.89
98.97
99.60
FL:98.74
TC:98.99
FL:98.76
FL:99.02
TC:99.52
(99.00)
1.3%
1.5%
2.9%
2.
9%
1.
4%
7.
0% 6.
9%
1.
3% 1.
4%
4.
5% 4.
1%
1.
0%
1.4%
1.7
7.3%
4.
8%
1.2%
1.5%
2.0%
5.
9.
5.
4.
1.
7.
4.
5.
9.
5.
5.
5.00'
4.68' 5.44'
6.96'
7.00'
5.11'
5.00'5.00'
5.00'
5.00'
5.
5.
1+00 1+25 1+48.27
-1.39%
ST
A
.5
EL
EV
9.
ST
A
.2
EL
EV
8.
-1.39%
ST
A
.5
EL
EV
9.
ST
A
.2
EL
EV
8.
Ramp Landing
BC01
CU
RB
R
AM
P
DE
TA
ILS
0 52.55
Scale: 1" = 5'
ABBREVIATION
TC = Top Face of Curb (Elevation ft.)
BC = Bottom Face of Curb (Elevation ft.)
FL = Flow Line Along Gutter (Elevation ft.)
(XXX.XX) = Match Extg. Grade
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\
BC
-C
UR
B
RA
M P
DE
TA
IL
S-
8.
dw g Pl ot S ta m p:
/2 4/
:4
7:
A M
Er ic Ge rm un ds on
EN
G I NEER
OREGON
AL
ION
SSPROFEREDSTEIGRE
RENEWS:06/30/2027
90732PE
ER IC EDW A R D GERMUNDSO
N
M A Y 14 , 2 0 19
SW
P ilk in gt on
R oa d
Truncated dome detectable warning surface
Turning space
Sidewalk
LEGEND
Transition panel*
Relocate utility pole
Sawcut
Existing GradeFinish Grade at FL
CURB RETURN PROFILE
Horizontal Scale: 1"=10'
Vertical Scale: 1"=2'
R/ W
RRFB Pole
R/ W
"PNW" Sta. 1+07.50
"PNW" Line
"PNW" Sta. 1+38.27
GENERAL NOTES
1. Slopes hold over elevations. contractor shall take all necessary field measurements to verify plan design meets ADA compliance and notify the engineer if the ramps cannot be constructed as shown.
Refer to specification section 00759 for full requirements.
2. See ODOT Std. Dwgs. RD900 through RD960 for details not shown.
3. Contractor shall keep the concrete structure free from contact, strain, and public traffic for at least 7 calendar days or longer as directed according to standard specification 00759.51.
4. Contractor shall notify Clackamas County once ramps are completed for a post ramp construction inspection.
F
F
F F
F F
F F
F F
F F
F F
F F
F
F F F F F
F F
F F
F
F F F F F F F F F F
F F
F F
F F
F F
F F
F F
F F
F F
TC:(99.22)
TC:99.03
TC:98.95
TC:98.67 TC:98.71
TC:(98.74)
FL:98.47
FL:98.17 FL:98.21
FL:(98.24)
FL:98.53
FL:(98.72)
PI
: 1
.0
PC
: 1
.8
Mid:
1+
.71
PT: 1+35.55
PC: 1+40.56
Mid: 1+44.18
PRC: 1+47.79
Mid: 1+51.40
PT: 1+55.02
L15.68' R10.00' D89.85
L7.23' R10.00'
98.86 98.93 98.98
98.8698.78
7.2%
7.3% 1.5% 1.0%
1.5%
1.
5%
7.
2%
7.
3%
0.8%
1.
3%
1.0%
4.0%
4.
0%
5.
15.69'
5.00' 4.50'
5.
5.00'4.50'
L7.23' R10.00'
4.
1.
5%
1.
5%
98.91
98.96 99.03
5.00'
5.
1.4%
0.
7%
1.
1%
1+00 1+25 1+50 1+65.02 Ramp Landing
Ramp Landing
-0.80% -0.80% -0.80% 2.81% 1.31% 1.31%
ST
A
.3
EL
EV
8.
ST
A
.8
EL
EV
8.
ST
A
.8
EL
EV
8.
ST
A
.7
EL
EV
8.
ST
A
.5
EL
EV
8.
ST
A
.5
EL
EV
8.
ST
A
.0
EL
EV
8.
-0.80% -0.80% -0.80% 2.81% 1.31% 1.31%
ST
A
.3
EL
EV
8.
ST
A
.8
EL
EV
8.
ST
A
.8
EL
EV
8.
ST
A
.7
EL
EV
8.
ST
A
.5
EL
EV
8.
ST
A
.5
EL
EV
8.
ST
A
.0
EL
EV
8.
BC02
SW Dawn Street
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\
BC
-C
UR
B
RA
M P
DE
TA
IL
S-
8.
dw g Pl ot S ta m p:
/2 4/
:4
7:
A M
Er ic Ge rm un ds on
EN
G I NEER
OREGON
AL
ION
SSPROFEREDSTEIGRE
RENEWS:06/30/2027
90732PE
ER IC EDW A R D GERMUNDSO
N
M A Y 14 , 2 0 19
SW
P ilk in gt on
R oa d
0 52.55
Scale: 1" = 5'
CU
RB
R
AM
P
DE
TA
ILS
R/W
R/ W
Sawcut
RRFB Pole
"PNE" Sta. 1+55.02
"PNE" Line
"PNE"
Sta. 1+10.34
Existing Grade
"PNE"
Sta. 1+23.76
CURB RETURN PROFILE
Horizontal Scale: 1"=10'
Vertical Scale: 1"=2'
ABBREVIATION
TC = Top Face of Curb (Elevation ft.)
BC = Bottom Face of Curb (Elevation ft.)
FL = Flow Line Along Gutter (Elevation ft.)
(XXX.XX) = Match Extg. Grade
GENERAL NOTES
1. Slopes hold over elevations. contractor shall take all necessary field measurements to verify plan design meets ADA compliance and notify the engineer if the ramps cannot be constructed as shown.
Refer to specification section 00759 for full requirements.
2. See ODOT Std. Dwgs. RD900 through RD960 for details not shown.
3. Contractor shall keep the concrete structure free from contact, strain, and public traffic for at least 7 calendar days or longer as directed according to standard specification 00759.51.
4. Contractor shall notify Clackamas County once ramps are completed for a post ramp construction inspection.
Truncated dome detectable warning surface
Turning space
Sidewalk
LEGEND
Transition panel*
1+00
1+
1+
1+
EN
G I NEER
OREGON
AL
ION
SSPROFEREDSTEIGRE
RENEWS:06/30/2027
90732PE
ER I C EDW A R D GERMUNDSO
N
M A Y 14 , 2 0 19
CONSTRUCTION NOTES
1 Sawcut & remove extg. pavement, sidewalk, and curb
SW Dawn Street
SW
P ilk in gt on
R oa d
Pilkington Park Driveway
R/W
R/W
R/ W
0 201020
Scale: 1" = 20'
3 Const. Standard Curb (See County Std. Dwg. No. S100)1
5 Const. concrete walks (See County Std. Dwg. No. S960)
6 Const. curb ramp Inst. truncated domes on new surfaces (See shts BC01 thru BC02 for details)
8 Utility pole to be relocated by Ziply
69 9 Remove existing storm drain inlet
10 Install curb inlet with GB basin with 18" sump.
Connect to existing 12" pipe Rim = 98.15 I.E. Out (South) = 96.01 (Match Extg.)
(See WES Std. Dwg. No. SWM-14 and SWM-18)
C01
GE
NE
RA
L C
ON
ST
RU
CT
IO
N
19050 SW Pilkington Rd Taxlot No. 4100
19040 SW Pilkington Rd Taxlot No. 4007
19043 SW Pilkington Rd Taxlot No. 2600
11 Inst. bark mulch, 4" depth
12 Inst. permanent lawn seeding over 4" topsoil
2 Construct AC Standard Structural Section for Collector (See County Std. Dwg. No. C100)
7 Const. grouted riprap (See sht BB01 for details)
13 Remove existing sign (See sht. Signing and Striping Plans for details)
"PNE" Line
"PNW" Line
4 Const. Standard Curb and Gutter (See County Std. Dwg. No. S150) Sta. "PNW" 1+07.50 to 1+38.27 Sta. "PNE" 1+10.34 to 1+55.02
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\
FB
-G
RA
DI
NG
E
RO
SI
ON
-3
.d w g Pl ot S ta m p:
/2 4/
:4
8:
A M
Er ic Ge rm un ds on
EN
G I NEER
OREGON
AL
ION
SSPROFEREDSTEIGRE
RENEWS:06/30/2027
90732PE
ER I C EDW A R D GERMUNDSO
N
M A Y 14 , 2 0 19
LEGEND
SW Dawn Street
SW
P ilk in gt on
R oa d
Pilkington Park Driveway
R/W
R/W R/
W
0 201020
Scale: 1" = 20'
Existing ROW Line
Proposed Major Contours250
Extg./Proposed CB Flow Arrow
Existing Major Contours250 Existing Minor Contours249
Proposed Minor Contours249
Inlet Protection
Trees to Remain
CONSTRUCTION NOTES
1 Install Inlet Protection.
(See WES Std. Dwg. No. 4-24)
2 Install Check Dam Biofilter Bags.
(See WES Std. Dwg. No 4-9)
3 Area of Seed or Mulch Restoration.
(See Sht. C01 for Details)
FB01
ER
OS
IO
N
SE
DI
ME
NT
C
ON
TR
OL
Biofilter bags
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ M
-S
IG
NA
L-
8.
dw g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
PGE to connect power service (Work Order #M5952294)PWR
S Install (S=size) inch conduit.
Preserve and protect utility pole.EX
UP
BMC Install base mounted service cabinet, 100A, 120/240 volt, metered, for RRFB. See Wiring Diagram on MC01.
BMC shall be FOUCH or approved equal.
W Install conduit and wiring per PGE requirements.
1. All streetlights shall be PGE Schedule 95 Option A.
2. All materials and workmanship shall conform to the Clackamas County Ordinances and special provisions, the 2024 Oregon Standard Specifications for Construction, the referenced Oregon Standard Drawings, and PGE requirements.
3. All electrical equipment shall conform to the current standards of the National Electrical Manufacturers Association (NEMA) and the Underwriters Laboratories, Inc. (U.L.) wherever applicable. In addition to the requirements of the plans, standard specifications, and the special provisions, all materials and workmanship shall conform to the current requirements of the National Electrical Code (NEC) the National Electrical Safety Code, standards of the American National Standards Institute (ANSI), and any local ordinances which may apply.
4. Location of illumination conduits and junction boxes are approximate. Coordinate with other utilities to ensure proper installation.
5. Contractor shall coordinate with PGE for power service for the RRFB and street lighting system(s). The contractor shall coordinate wiring to the power source as required by PGE. The contractor shall coordinate with ERIC PARKER (RRFB Service, 503-806-3556) and RICO TORRES SOLIS (Illumination, 503-403-9084) a minimum of 4 weeks before starting PGE related infrastructure to schedule a coordination meeting for all power requirements. Reference PGE Work Order M5952294 (RRFB Service) and M5952300 (Illumination).
Contractor shall contact PGE a minimum of 2 weeks prior to required PGE inspections.
6. Equipment submittals shall be provided to PGE by the contractor after an initial review has been completed by the project engineer. PGE approval of these submittals must be obtained prior to construction.
7. Existing street lights shall remain operational during construction unless approved otherwise in writing by Clackamas County.
8. Location of poles, junction boxes, and conduit shall be installed as shown on plans. If conflicts arise, pole, junction box, and conduit location may be modified in the field per engineer approval. All equipment must be placed within the right of way. Place conduit in the same trench as other conduits when possible.
9. The contractor shall verify the locations of existing utilities and coordinate this work with the utility companies/agencies to eliminate any conflicts.
10. The engineer shall field verify the location of all signal equipment before installation.
11. All concrete boxes shall be placed in sidewalk or concrete apron.
12. Install #12 standard copper (orange) tracer wire in all conduits. Ground all tracer wires.
13. Conduits shall be placed in the same trench with other conduits when possible.
14. Top of signal and pedestrian pole foundations shall match top of finished grade of sidewalk.
15. All conduit runs shall be placed within the right-of-way.
16. Install poly pull tape (1800 lbf min. strength, non-conductive) in all conduits.
17. All underground conduits and fittings shall be schedule 80 PVC.
LEGEND
Install 17"x10"x12" (min. dimension) precast concrete junction box with concrete apron.
JB
1A
HDD Install conduit by horizontal directional drilling, open trench not allowed.
Install light pole number (N), see lighting notes and light pole and luminaire schedule.
LP
(N)
1. The luminaire shall be a PGE approved LED, supplied and installed by PGE. The PGE approved luminaire is:
Manufacturer: Catalog Number:
Leotek, 88W LED GCM2-40H-MV-WW-2R-GY-700-PCR7-RWG-WL-FDC-PGE
2. The photoelectric control relay shall be extended life twist lock and PGE approved.
3. The pole type for the proposed pole shall be supplied and installed by PGE.
Streetlight Pole: Catalog Number:
Valmont 250075105D4Z-SBF-11"BC Hapco 41-103PGE P&K Poles (Flagpole Inc) RTA7L25AAD1432D
4. Anchor pole footing shall be PGE-approved precast concrete base, supplied by PGE and installed by the contractor. The PGE-approved footing shall be 14" square by 60" high.
5. The PGE approved junction boxes are:
Streetlight 1730 J-Box: Catalog Number:
Newbasis - 17"x30"x18" (90003480) FCA173018T-90026 Quazite (Hubbell) - 17"x30"x18" (90003480) A42173018A017 Oldcastle/Carson Industries - 17"x30"x18" (90003480) 17301726 Highline - 17"x30"x18" (90003480) CHA173018HE1 Armorcast - 17"x30"x18" (90003480) A6001640TAX18
6. Wire for use between the junction box and the fixture shall be: #10 AWG, 600 Volt, 3-Conductor, Class B Stranding, Type TC, with Sunlight-Resistant 45-mil PVC Jacket. Suitable for direct burial installations. Insulation to be black, red, and green per NEMA WC-7 for NEC appli-cations (TFN, THWN, THHN), with fillers or binding tape added to produce round outer jacket, rated 90ᵒC dry and 75ᵒC wet, 1,000 ft NR reels. Jacket to display sequential footage markings. 2 reel labels, one attached to the outside flange surface, one attached to the drum wrapping; each to detail total footage, inside or starting footage. Contact PGE for suppliers.
PGE APPROVED STREET LIGHTING EQUIPMENT
MA01
CC Install actuated beacon system controller cabinet.
BMC
Install (X=Number) sided rectangular rapid flashing beacon system (pedestrian pedestal, with florescent yellow-green S1-1 sign) using Clackamas County preferred manufacturer or approved equal per Clackamas County Std. Dwg. T400.
XR
PP
LUM Install new luminaire with photocell. See light pole schedule.
Install approved 17"x30"x18" precast concrete junction box per PGE specifications.
JB
PGE
RR
FB
A
ND
IL
LU
MI
NA
TI
ON
LE
GE
ND
Accompanied by ODOT Standard Dwgs.:
TM457, TM467, TM470, TM482, TM485,
TM700, TM701, TM702
CABINETS
POLES
JUNCTION BOXES
CONDUITS
WIRES & CABLES
GENERAL NOTES
Install 22"x12"x12" (min. dimension) precast concrete junction box with concrete apron.
JB
2A
N G Install (N=Number) no, (G-AWG wire size) XHHW wire.
PL
LW
Install poly pull tape (1800 lbf min. strength, non-conductive).
Install #12 copper standard (orange) tracer wire.
Remove existing luminaire.RX
LUM
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHWOHWOHWOHWOHWOHWOHWOHW
OH
W
OH
W
OH
W
OH
W
OHW OHW OHW OHW OHW
OHW
OHW
OHW
OHW
OHW
OHW
OHW OHW
1+
1+
1+00
1+
0 10510
Scale: 1" = 10'
MB01
RR
FB
A
ND
IL
LU
MI
NA
TI
ON
P
LA
N
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ M
-S
IG
NA
L-
8.
dw g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
JB
2R
PP
2R
PP
JB
2A
BMC
3HDD
W
CCPOLE NO. 1
POLE NO. 2CC
EX
UP PWR
CONSTRUCTION NOTES:
Coordinate power source and connection details for street lighting system with PGE. Reference PGE Job M5952300.
Coordinate power source connection for RRFB system with PGE. Reference PGE Job M5952294.
Trim 10' of tree branches to provide space for new street light pole installation.
Contractor to retain and protect existing PGE conduit that goes from existing pole D2119A-4727 to the north.
GENERAL NOTES
1. See Sheet MA01 for legend.
2. Field verify all measurements.
3. Water main estimated depth 24" from top of nut to existing pavement
4. Gas line estimated cover varies from 25" to 31". Pothole data available upon request.
LP
JB
PGE
SW Dawn Street
SW
P ilk in gt on
R oa d Pilkington Park Driveway
W
W
LUM
1+34.93 "PNE", 5.98' RT
1+24.05 "PNW", 6.08'RT
3"
3"
HDD
HDD
"PNE" Line
"PNW" Line
R/W
R/ W
R/ W R/
W
New Pole Location Subject to Approved Ziply Relocation Plan
JB
PGE
6 10
W 3"
HDD
3 10
W
PL LW
PL LW
3 10PL LW
3 10PL LW
PL LW
RX
LUM
Pole No. D2119A-4727
See Note 3
See Note 4
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ M
-S
IG
NA
L-
8.
dw g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
MC01
RR
FB
D
ET
AI
LS
N
The north arrow shown relates to zero degrees on Pedestrian and Vehicle signal poles. Degrees shown in the pole entrance chart show the degrees clockwise from plan sheet north arrow (zero) to equipment located on the pole.
ORIENTATION DIAGRAM
PEDESTRIAN PEDESTAL / VEHICLE PEDESTAL
ORIENTATION DIAGRAM
NOTE:
Equipment shown on the orientation diagram is a clarification of angles of equipment that may be located on a pedestrian pedestal or vehicle pedestal.
of Pedestrian
Head
℄ of Vehicle Signal Head
℄ of Pedestrian Head
Ø
Ø
Ø
LIGHT POLE TABLE
CROSSWALK PHOTOMETRIC ANALYSIS SUMMARY
EQUIPMENT ON POLE
RECT. FLASH
BEACON
DEG.NO. TYPEPOLE PED.
PUSHBUTTON
DEG.
See
TM650
thru
TM653
SIGN
DEG.
2 PP/3
PP/3
0/180
0/180
0/180
0/180
POLE ENTRANCE CHART
Circuit Breaker(20 A, 277 V, 1-P)
Main Breaker(100 A, 480 V, 2-P)
120/240 Volt Single PhasePower Source
To RRFB CircuitAC+
GND
AC-
M(T(R
S(RV,C( CAB,N(T :,R,NG F2R
120/240 V2/T S,GNA/ S(RV,C(
BMC
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ M
-S
IG
NA
L-
8.
dw g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
MC02
RR
FB
D
ET
AI
LS
RX
SLM
0 201020
Scale: 1" = 20'
QA01
SI
GN
IN
G
ST
RI
PI
NG
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ Q-
SI
GN
IN
G
ST
RI
PI
NG
-3
.d w g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
STRIPING LEGEND SIGNING LEGEND
Install staggered continental crosswalk 2' white bars per Oregon Standard Drawing TM503.CW-SC
CW-SC
S
NDW-2
Install 8" line (white) per Oregon Standard Drawing
TM500.
W-2
ND
S
Install 4" narrow double stripe (yellow) per Oregon Standard Drawing TM500.
Install stop bar per Oregon Standard Drawing TM503.
Remove existing shared lane marking.
RX
SLM
RX
SLM
RX
CW
RX
S
RX
CW Remove existing crosswalk
RX
S Remove existing stop bar
Install new sign (N).
Install new sign (N) on new (M) sign support.N M
N
Remove existing sign (N) and (M) sign supportRXN M
Remove existing sign (N) from existing sign supportRXN
S
RX1
S
RX2
S RX3
S 102a
RX2
S
RX3
RX4
RX5
101a
101b
SW Dawn Street
SW
P ilk in gt on
R oa d
Pilkington Park Driveway
Match Existing
11' 21.75'7'
EX
W-2 Retain and protect existing 8" white line.
EX
W-2
RRFB
Install RRFB with school crossing sign (S1-1) per Flashing Beacon plans.RRFB
RRFB
R/W
R/W
R/ W
R/ W
70'70'
S
102a
N = Sign Number M - Material options are:
S = Perforated Steel Square Tube Sign Support
200' from crosswalk
Approx. 280' from crosswalk
STRIPING GENERAL NOTES
1. All pavement markings shall conform to the requirements and specifications of the Manual on Uniform Traffic
Control Devices (M.U.T.C.D.) 11th Edition, and the Oregon Supplement to the M.U.T.C.D., and the 2024 Oregon Standard Specifications for construction.
2. All pre-markers for pavement markings and striping locations shall be approved by the Engineer prior to final placement.
3. All longitudinal pavement striping shall be method "A" thermoplastic, extruded, surface, non-profiled.
4. All pavement bars and legends shall be Type B-HS.
5. Existing markings not shown are to remain in place unless otherwise directed by the Engineer.
6. Existing striping removed during scoring and repaving to be installed as shown.
7. Refer to ODOT Standard Drawings TM500, TM501, TM502, and TM503 for all pavement marking details.
SIGNING GENERAL NOTES
1. All signing shall conform to the requirements and specifications of the Manual on Uniform Traffic Control Devices
(M.U.T.C.D.) 11th Edition, and the Oregon Supplement to the M.U.T.C.D.
2. The locations of sign installation shown are approximate with the exact location to be determined in the field.
3. Existing signs not shown are to remain in place unless otherwise shown.
4. Signs located on traffic signal poles reference the signal design plans.
5. Traffic sign legend and mounting details are shown on sheets QA02.
6. Refer to Clackamas County Standard Drawings T100, T130, T150, and T250 for Street Name sign and mounting details.
EX
ND
EX
ND Retain and protect existing narrow double no pass lane.
W-2 4'
RX2
S RX6
EX
W-2
EX
W-2
EX
ND
EX
ND
1 2 3 4 5 6
R1-1 36"x36" 1 Required
S1-1 36"x36" 2 Required
102a W16-9P 24"x12" 2 Required
101b D3-1 42"x12" 1 Required
101a D3-1 60"x12" 1 Required
5'-0"3'-6"
1'-0" 1'-0"
M a r c h 9 , 2 0 2 1
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ Q-
SI
GN
IN
G
ST
RI
PI
NG
-3
.d w g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
EXISTING SIGN LEGEND
PROPOSED SIGN LEGEND
QA02
SI
GN
IN
G
ST
RI
PI
NG
S A R A P A R K S
93121PE
RENEWS: 12/31/26
OREGON
ENG INEER
RE
GIS
TERED PROFESSIONAL
Fi le
: H
\3
Pi lk in gt on
R d
En ha nc ed
C ro ss w al k\ de sig n\ _C
D\ Q-
SI
GN
IN
G
ST
RI
PI
NG
-3
.d w g Pl ot S ta m p:
/2 4/
:4
9:
A M
Er ic Ge rm un ds on
QA03
SI
GN
IN
G
ST
RI
PI
NG
| Sheets and Views |
| A01 A-TITLESHEET-31928 |
| A02 A-TITLESHEET-31928 - A02 |
| BB01 BC-CURB RAMP DETAILS-31928 - BB01 |
| BC01 BC-CURB RAMP DETAILS-31928 - BC01 |
| BC02 BC-CURB RAMP DETAILS-31928 - BC02 |
| C01 C-GENERAL CONSTRUCTION-31928 - C01 |
| FB01 FB-GRADING & EROSION-31928 - FB01 |
| MA01 M-SIGNAL-31928 - MA01 |
| MB01 M-SIGNAL-31928 - MB01 |
| MC01 M-SIGNAL-31928 - MC01 |
| MC02 M-SIGNAL-31928 - MC02 |
| QA01 SIGNING & STRIPING |
| QA02 SIGNING & STRIPING |
| QA03 SIGNING & STRIPING |
| 2026-06-24T14:55:19-0700 | |
| Sara J Parks |
| 2026-06-24T10:07:43-0700 | |
| Eric E Germundson |
File details come from the government source that posted it. Updated .