Predictive_Analytics_Sensor_Technology_Equipment_list.xlsx
XLSX spreadsheet 19 KB Posted
- Solicitation number
- 26-002-RFP
- Issued by
- Kenton County, Kentucky
About this file
This is an equipment inventory list for the Kenton County Airport Board (KCAB) in Kentucky, detailing assets relevant to a request for proposals for Predictive Analytic Sensors Technology and Maintenance. The spreadsheet catalogs HVAC systems, pumps, and baggage handling systems across multiple facility locations including Concourse A, Concourse B, the Police Department, and various utility rooms. The equipment inventory includes chillers, air handling units, computer room units, rooftop units, and associated pump systems, with detailed specifications such as model numbers, serial numbers, manufacturing years, and replacement values. Proposals for predictive analytics sensors technology and maintenance services are due by Thursday, February 5, 2026 at 2:00 pm, with questions to be submitted by Monday, January 26, 2026 at 11:59 pm and answers posted no later than Thursday, January 29, 2026 at 11:59 pm.
The equipment list reflects a mix of asset ages and conditions, with chillers manufactured between 1990 and 2024 from manufacturers including Carrier Corporation, York, Trane, and Liebert. Several assets show recent acquisition dates (2020-2024) with high criticality ratings, while older equipment such as chillers from 2000 and a Police Department unit from 1990 are rated as low criticality. Individual equipment replacement values range from approximately $8,700 to $1.3 million, with most HVAC components having a 20 to 25-year service life. The inventory indicates KCAB is seeking predictive analytics capabilities to monitor and maintain critical infrastructure across its airport facilities, though specific pricing terms, funding sources, and contract duration details are not provided in this equipment asset document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Predictive_Analytic_Sensors_Technology_and_Maintenance.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Asset | Unit # (09) | Description | Model | Serial Number | Location | Class | Category | Status | Condition Score (19) | Criticality | Mfr. Description (02) | Year Built | Purchase Cost | Replacement Value | Service Life (years) | X Coordinate | Y Coordinate | Z Coordinate |
| 14511 | PCA-CH-CB-01 | Concourse B, Chiller, PCA-CH-CB-01 | 30XWB40006-0-GXXB | 2924Q901357 | L.CONC.12 | HVAC | CHILLER | Active | GOOD | 3 - High Criticality | CARRIER CORPORATION | 2024 | 25 | |||||
| 14512 | PCA-CH-CB-02 | Concourse B, Chiller, PCA-CH-CB-02 | 30XWB40006-0-GXXB | 3024Q901375 | L.CONC.11 | HVAC | CHILLER | Active | GOOD | 3 - High Criticality | CARRIER CORPORATION | 2024 | 25 | |||||
| HVAC.CH.00003 | CH-PD-01 | Police Department, Chiller, CH-PD-01 | 38AK-044-600 | 2790FF24122 | L.BLDG.20 | HVAC | CHILLER | Active | FAIR | 1 - Low Criticality | CARRIER CORPORATION | 1990 | 250000 | 25 | ||||
| HVAC.CH.00009 | CH-CB-01 | Concourse B, Chiller, CH-CB-01 | YKV1WCK7-DJHS | SDJM769060 | L.CONC.12 | HVAC | CHILLER | Active | 2 - Medium Criticality | YORK | 2020 | 1294453.45 | 25 | |||||
| HVAC.CH.00010 | CH-CA-01 | Concourse A, Chiller, CH-CA-01 (PCA) | YVAA0413 | L.CONC.11 | HVAC | CHILLER | Active | GOOD | 3 - High Criticality | YORK | 2020 | 293145.3 | 25 | |||||
| HVAC.CH.00011 | CH-OF-01 | CVG Centre, Chiller, CH-OF-01 | YKDPDPQ7-ENH | SNJM923420 | L.BLDG.61 | HVAC | CHILLER | Active | GOOD | 1 - Low Criticality | YORK | 2000 | 339521.3 | 25 | -84.662707 | 39.041704 | ||
| HVAC.CH.00012 | CH-OF-02 | CVG Centre, Chiller, CH-OF-02 | YKDPDPQ7-ENH | SNJM923640 | L.BLDG.61 | HVAC | CHILLER | Active | GOOD | 1 - Low Criticality | YORK | 2000 | 339521.3 | 25 | -84.662577 | 39.041654 | ||
| HVAC.AHU.00149 | AHU-CSB-01 | CSB, Air Handling Unit, AHU-CSB-01 | CSAA100UBL00 | K19M94909 | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | 2 - Medium Criticality | TRANE | 2021 | 164837 | 20 | |||||
| HVAC.AHU.00150 | AHU-CSB-02 | CSB, Air Handling Unit, AHU-CSB-02 | CSAA050UBL00 | K20A01662 | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | 2 - Medium Criticality | TRANE | 2021 | 121000 | 20 | |||||
| HVAC.AHU.00151 | AHU-CSB-03 | CSB, Air Handling Unit, AHU-CSB-03 | CSAA050UBL00 | K20A01678 | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | 2 - Medium Criticality | TRANE | 2021 | 121000 | 20 | |||||
| HVAC.AHU.00152 | AHU-CSB-04 | CSB, Air Handling Unit, AHU-CSB-04 | CSAA057UBL00 | K19M96406 | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | 2 - Medium Criticality | TRANE | 2021 | 164837 | 20 | |||||
| HVAC.CRU.00014 | CRU-CSB-01 | CSB, Liebert Computer Room Unit, CRU-CSB-01 | VS070ADA0E1949E | N20B8E0038 | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | GOOD | 2 - Medium Criticality | LIEBERT | 2021 | 40400 | 20 | ||||
| HVAC.CRU.00015 | CRU-CSB-02 | CSB, Liebert Computer Roon Unit, CRU-CSB-02 | VS070ADA0E1949E | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | GOOD | 2 - Medium Criticality | LIEBERT | 2021 | 40400 | 20 | |||||
| HVAC.RMU.00025 | RTU-CSB-01 | CSB, Rooftop Unit, RTU-CSB-01 | YSC102H4RMA03H6B1A1A600000000D | 201011962L | L.BLDG.152 | HVAC | AIR HANDLING UNIT | Active | GOOD | 1 - Low Criticality | TRANE | 2021 | 8700 | 20 | -84.658146 | 39.05574 | ||
| HVAC.CHWP.00002 | CHWP-CA-27 | Concourse A, Chilled Water Pump, CHWP-CA-27 | ||||||||||||||||
| HVAC.CHWP.00003 | CHWP-CA-28 | Concourse A, Chilled Water Pump, CHWP-CA-28 | ||||||||||||||||
| HVAC.CHWP.00004 | CHWP-CA-05 | Concourse A, Chilled Water Pump, Secondary, CHWP-CA-05 | ||||||||||||||||
| HVAC.CHWP.00005 | CHWP-CA-06 | Concourse A, Chilled Water Pump, Secondary, CHWP-CA-06 | ||||||||||||||||
| HVAC.HWP.00001 | HWP-CA-01 | Concourse A, Hot Water Pump, HWP-CA-01 | ||||||||||||||||
| HVAC.HWP.00002 | HWP-CA-10 | Concourse A, Hot Water Pump, HWP-CA-10 | ||||||||||||||||
| HVAC.HWP.00003 | HWP-CA-11 | Concourse A, Hot Water Pump, HWP-CA-11 | ||||||||||||||||
| HVAC.HWP.00004 | HWP-CA-12 | Concourse A, Hot Water Pump, HWP-CA-12 | ||||||||||||||||
| HVAC.HWP.00006 | HWP-CA-19 | Concourse A, Hot Water Pump,Secondary, HWP-CA-19 | ||||||||||||||||
| HVAC.HWP.00008 | HWP-CA-02 | Concourse A, Hot Water Pump, HWP-CA-02 | ||||||||||||||||
| HVAC.HWP.00009 | HWP-CA-20 | Concourse A, Hot Water Pump, Secondary, HWP-CA-20 | ||||||||||||||||
| HVAC.HWP.00010 | HWP-CA-21 | Concourse A, Hot Water Pump, Secondary, HWP-CA-21 | ||||||||||||||||
| HVAC.HWP.00011 | HWP-CA-22 | Concourse A, Hot Water Pump, Secondary, HWP-CA-22 | ||||||||||||||||
| HVAC.HWP.00012 | HWP-CA-23 | Concourse A, Hot Water Pump, Secondary, HWP-CA-23 | ||||||||||||||||
| HVAC.HWP.00013 | HWP-CA-24 | Concourse A, Hot Water Pump, Secondary, HWP-CA-24 | ||||||||||||||||
| HVAC.HWP.00014 | HWP-CA-25 | Concourse A, Hot Water Pump,Primary, HWP-CA-25 | ||||||||||||||||
| HVAC.HWP.00015 | HWP-CA-26 | Concourse A, Hot Water Pump,Primary, HWP-CA-26 | ||||||||||||||||
| HVAC.HWP.00016 | HWP-CA-29 | Concourse A, Hot Water Pump, HWP-CA-29 | ||||||||||||||||
| HVAC.HWP.00017 | HWP-CA-03 | Concourse A, Hot Water Pump, HWP-CA-03 | ||||||||||||||||
| HVAC.HWP.00018 | HWP-CA-07 | Concourse A, Hot Water Pump, Secondary, HWP-CA-07 | ||||||||||||||||
| HVAC.HWP.00019 | HWP-CA-08 | Concourse A, Hot Water Pump, Secondary, HWP-CA-08 | ||||||||||||||||
| HVAC.HWP.00020 | HWP-CA-09 | Concourse A, Hot Water Pump, Secondary, HWP-CA-09 | ||||||||||||||||
| HVAC.HWP.00057 | HWP-CA-01 | Concourse A, Hot Water Pump, HWP-CA-01 | ||||||||||||||||
| 11564 | PCAPUMP-CB-3A | Concourse B, Condensor Pump, PCAPUMP-CB-3A | ||||||||||||||||
| 14642 | PCAPUMP-CB-1A | Concourse B, Chilled Water Pump, Primary, PCAPUMP-CB-1A | ||||||||||||||||
| 14643 | PCAPUMP-CB-1B | Concourse B, Chilled Water Pump, Primary, PCAPUMP-CB-1B | ||||||||||||||||
| HVAC.CHWP.00006 | CHWP-CA-27 | Concourse A, Chilled Water Pump, CHWP-CA-29 | ||||||||||||||||
| HVAC.CHWP.00007 | CHWP-CA-28 | Concourse A, Chilled Water Pump, CHWP-CA-30 | ||||||||||||||||
| HVAC.CHWP.00008 | CHWP-CA-05 | Concourse A, Chilled Water Pump, Secondary, CHWP-CA-07 | ||||||||||||||||
| HVAC.CHWP.00009 | CHWP-CA-06 | Concourse A, Chilled Water Pump, Secondary, CHWP-CA-08 | ||||||||||||||||
| HVAC.HWP.00001 | HWP-CA-01 | Concourse A, Hot Water Pump, HWP-CA-01 | ||||||||||||||||
| HVAC.HWP.00002 | HWP-CA-10 | Concourse A, Hot Water Pump, HWP-CA-10 | ||||||||||||||||
| HVAC.HWP.00003 | HWP-CA-11 | Concourse A, Hot Water Pump, HWP-CA-11 | ||||||||||||||||
| HVAC.HWP.00004 | HWP-CA-12 | Concourse A, Hot Water Pump, HWP-CA-12 | ||||||||||||||||
| HVAC.HWP.00006 | HWP-CA-19 | Concourse A, Hot Water Pump,Secondary, HWP-CA-20 | ||||||||||||||||
| HVAC.HWP.00008 | HWP-CA-02 | Concourse A, Hot Water Pump, HWP-CA-03 | ||||||||||||||||
| HVAC.HWP.00009 | HWP-CA-20 | Concourse A, Hot Water Pump, Secondary, HWP-CA-25 | ||||||||||||||||
| HVAC.HWP.00010 | HWP-CA-21 | Concourse A, Hot Water Pump, Secondary, HWP-CA-26 | ||||||||||||||||
| HVAC.HWP.00011 | HWP-CA-22 | Concourse A, Hot Water Pump, Secondary, HWP-CA-27 | ||||||||||||||||
| HVAC.HWP.00012 | HWP-CA-23 | Concourse A, Hot Water Pump, Secondary, HWP-CA-28 | ||||||||||||||||
| Utilities - Waste Water - LCP-1 - Turbo Air Compressor | ||||||||||||||||||
| Utilities - Waste Water - LCP-2 - Turbo Air Compressor | ||||||||||||||||||
| Utilities - Waste Water - LCP-3 - Turbo Air Compressor | ||||||||||||||||||
| Utilities - Waste Water - LCP-4 - Turbo Air Compressor | ||||||||||||||||||
| Utilities - Terminal Chiller Room - Chiller C-TD-1 - Chiller | ||||||||||||||||||
| Utilities - Terminal Chiller Room - Chiller C-TD-2 - Chiller | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-TD-1 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-TD-2 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-T3-7 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-TD-3 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-TD-4 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-T3-8 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-T3-9 - Pump | ||||||||||||||||||
| Utilities - Terminal Chiller Room - P-T3-10 - Pump | ||||||||||||||||||
| Utilities - Boiler Room - P-TD-5 - Pump | ||||||||||||||||||
| Utilities - Boiler Room - P-TD-6 - Pump | ||||||||||||||||||
| Utilities - Boiler Room - Boiler 1 Comb Fan - Fan | ||||||||||||||||||
| Utilities - Boiler Room - Boiler 2 Comb Fan - Fan | ||||||||||||||||||
| Utilities - Boiler Room - Boiler 3 Comb Fan - Fan | ||||||||||||||||||
| Utilities - Plane Chiller Room - Pump 1 - Pump | ||||||||||||||||||
| Utilities - Plane Chiller Room - Pump 2 - Pump | ||||||||||||||||||
| Utilities - Plane Chiller Room - Chiller 1 - Chiller | ||||||||||||||||||
| Utilities - Plane Chiller Room - Chiller 2 - Chiller | ||||||||||||||||||
| Utilities - Plane Chiller Room - Freon Recovery Tank Pump 1 - Pump | ||||||||||||||||||
| BHS - TSA - SS1-13 - Conveyor | ||||||||||||||||||
| BHS - TSA - SS1-14 - Conveyor | ||||||||||||||||||
| BHS - TSA - SS1-15 - Conveyor | ||||||||||||||||||
| BHS - TSA - SS1-16 - Conveyor | ||||||||||||||||||
| BHS - TSA - SS1-16-PFD Arms - Actuating Arm | ||||||||||||||||||
| BHS - TSA - SS1-16-PFD Belts - Vertical Conveyors | ||||||||||||||||||
| BHS - Tunnel - ST-1 Terminal End - Conveyor | ||||||||||||||||||
| BHS - Tunnel - ST-1 Concourse End - Conveyor | ||||||||||||||||||
| BHS - Tunnel - ST-3 Terminal End - Conveyor | ||||||||||||||||||
| BHS - Tunnel - ST-3 Concourse End - Conveyor |