Plans - REVISED.pdf
PDF 16 MB Posted
- Attached to
- 26-08 Cal883432B (Calhoun)
- Solicitation number
- 26-08 Cal883432B (Calhoun)
- Issued by
- Calhoun County, Iowa
About this file
This is a revised construction plans document for the Iowa Department of Agriculture and Land Stewardship (IDALS) Water Resources Bureau for the Cal883432B Nutrient Reduction Wetland Project in Calhoun County, Iowa, near Lytton. The project scope encompasses selective clearing and vegetation management, excavation and grading of approximately 13,800 cubic yards of earthwork, installation of 769 linear feet of tile drainage (20 linear feet of 15-inch corrugated metal pipe and 581 linear feet of 12-inch high-density polyethylene dual-wall pipe with 153 linear feet of 10-inch non-perforated pipe), placement of 2,750 square feet of tied-concrete block erosion matting, construction of a 2-chamber water control structure with 54-inch corrugated metal pipe sleeve and slotted 18-inch riser, installation of bentonite anti-seep collars, placement of approximately 31 tons of riprap and erosion stone, and restoration seeding of approximately 4 acres including native buffer (3.0 acres), waterway seeding (0.2 acres), and cover crop seeding (1.2 acres). The project is located on property owned by Grodahl Farms Inc. in Section 32, Township 88 North, Range 34 West. Bids are due August 26, 2026 at 3:00 PM via the Iowa Management of Procurement and Contracts System (IMPACS). A pre-bid conference is scheduled for August 12, 2026 at 10:00 AM at the Calhoun County Conservation office in Rockwell City. Construction must be completed by November 30, 2026, with buffer and structure seeding due by December 15, 2026. Construction must commence within 7 days of a preconstruction conference held within 7 days prior to the approved start date.
The estimated construction cost range is $135,000 to $155,000. Contractors must register with the Iowa Department of Inspections, Appeals & Licensing and demonstrate ownership of at least 20 percent of their own equipment. Bidders must submit a proposal guarantee (bid bond) equal to 10 percent of the base bid and a notarized affidavit confirming no collusion or fraud. The successful bidder must furnish a performance bond equal to 100 percent of the contract price within 14 days of award. Liquidated damages are assessed at $175 per day for work other than seeding and $125 per day for seeding work. All work must comply with Calhoun County requirements and current Natural Resources Conservation Service (NRCS) construction specifications. The water control structure requires engineer-approved shop drawings prior to fabrication. Technical questions must be directed to Spencer Pech at ISG Inc. (spencer.pech@isginc.com, 563-920-5758) with a copy to Tracy Blocker, received by 3:00 PM on August 19, 2026.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Schedule of Prices Worksheet.pdf | ||
| Schedule of Prices - REVISED.pdf | ||
| Notice to Bidders.pdf | ||
| Proposal - Acknowledgment - Affidavit.pdf | ||
| Bid Bond.pdf | ||
| Proposal-Acknowledgment-Affidavit Doc CC.pdf | ||
| Specifications - REVISED.pdf | ||
| General Requirements.pdf | ||
| Specifications.pdf | ||
| Plans.pdf | ||
| Addendum 1 & Pre-bid.pdf | ||
| Appendix I.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CAL883432B Nutrient Reduction Wetland Project DOCUMENT CC – Attachment 1 Bid No. 26-8 PROPOSAL AND SCHEDULE OF PRICES
Attachment No. 2
Revised set of Plans
30402-C0-TITLE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0-
TI
TL
E.
D W
G
SA
VE
D B
Y:
L
U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
NUTRIENT REDUCTION WETLAND
CALHOUN COUNTY, IOWA
PROJECT INDEX:
OWNER:
IDALS
WATER RESOURCES BUREAU
HOOVER STATE OFFICE BUILDING
1305 E. WALNUT STREET
DES MOINES, IA 50319
PROJECT
ADDRESS / LOCATION:
SECTION 32/T88N/R34W
GARFIELD TWP
LYTTON, IA
PROJECT MANAGER: CALEB RASMUSSEN
EMAIL: CALEB.RASMUSSEN@ISGINC.COM
IDALS CAL883432B
ISG PROJECT # 24-30402
B.M. ELEVATION=1216.76
CUT "X" IN TOP OF RCP CULVERT SOUTH
SIDE OF FIELD DRIVE ALONG DURANT AVE
AND SOUTH PROPERTY LINE.
MANAGING OFFICE:
TOPOGRAPHIC SURVEY
THIS PROJECT'S TOPOGRAPHIC SURVEY CONSISTS
OF DATA COLLECTED IN APRIL 2024 BY ISG.
PROJECT GENERAL NOTES
GIS DISCLAIMER:
INFORMATION FOR THE BOUNDARY / LOT LINES, AND UNDERGROUND UTILITIES SHOWN WAS DERIVED FROM DIGITAL DATABASES AND IS FOR INFORMATIONAL PURPOSES ONLY. DATA MAY NOT HAVE BEEN
PREPARED FOR, OR BE SUITABLE FOR: LEGAL, ENGINEERING, OR SURVEYING PURPOSES.
LOCATION MAP
N
S
W E
PROJECT DATUM
HORIZONTAL COORDINATES HAVE BEEN REFERENCED TO THE
NORTH AMERICAN DATUM OF 1983 (NAD83), ON THE IOWA
REGIONAL ZONE 4 COORDINATE SYSTEM, IN U.S. SURVEY FEET.
ELEVATIONS HAVE BEEN REFERENCED TO THE NORTH
AMERICAN VERTICAL DATUM OF 1988 (NAVD 88).
RTK GPS METHODS WERE USED TO ESTABLISH HORIZONTAL AND
VERTICAL COORDINATES FOR THIS PROJECT.
SPECIFICATIONS REFERENCE
ALL CONSTRUCTION SHALL COMPLY WITH CALHOUN COUNTY'S
REQUIREMENTS AND WITH THE MOST RECENT NRCS
CONSTRUCTION SPECIFICATION, UNLESS DIRECTED
OTHERWISE.
1. ALL WORK SHALL CONFORM TO THE CONTRACT
DOCUMENTS, WHICH INCLUDE, BUT ARE NOT LIMITED TO,
THE OWNER - CONTRACTOR AGREEMENT, THE PROJECT
MANUAL (WHICH INCLUDES GENERAL SUPPLEMENTARY
CONDITIONS AND SPECIFICATIONS), DRAWINGS OF ALL
DISCIPLINES AND ALL ADDENDA, MODIFICATIONS, AND
CLARIFICATIONS ISSUED BY ARCHITECT/ENGINEER.
2. CONTRACT DOCUMENTS SHALL BE ISSUED TO ALL
SUBCONTRACTORS BY THE GENERAL CONTRACTOR IN
COMPLETE SETS IN ORDER TO ACHIEVE THE FULL EXTENT
AND COMPLETE COORDINATION OF ALL WORK.
3. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED
DIMENSIONS. NOTIFY ARCHITECT/ENGINEER OF ANY
DISCREPANCIES OR CONDITIONS REQUIRING INFORMATION
OR CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
4. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS.
NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES OR
CONDITIONS REQUIRING INFORMATION OR CLARIFICATION
BEFORE PROCEEDING WITH THE WORK.
5. DETAILS SHOWN ARE INTENDED TO BE INDICATIVE OF THE
PROFILES AND TYPE OF DETAILING REQUIRED
THROUGHOUT THE WORK. DETAILS NOT SHOWN ARE
SIMILAR IN CHARACTER TO DETAILS SHOWN. WHERE
SPECIFIC DIMENSIONS, DETAILS, OR DESIGN INTENT
CANNOT BE DETERMINED, NOTIFY ARCHITECT/ENGINEER
BEFORE PROCEEDING WITH THE WORK.
6. ALL MANUFACTURED ARTICLES, MATERIALS, AND
EQUIPMENT SHALL BE APPLIED, INSTALLED, CONNECTED,
ERECTED, CLEANED, AND CONDITIONED ACCORDING TO
MANUFACTURERS' INSTRUCTIONS. IN CASE OF
DISCREPANCIES BETWEEN MANUFACTURERS'
INSTRUCTIONS AND THE CONTRACT DOCUMENTS, NOTIFY
ARCHITECT/ENGINEER BEFORE PROCEEDING WITH THE
WORK.
7. ALL DISSIMILAR METALS SHALL BE EFFECTIVELY ISOLATED
FROM EACH OTHER TO AVOID GALVANIC CORROSION.
8. THE LOCATION AND TYPE OF ALL EXISTING UTILITIES
SHOWN ON THE PLANS ARE FOR GENERAL INFORMATION
ONLY AND ARE ACCURATE AND COMPLETE TO THE BEST
OF THE KNOWLEDGE OF I & S GROUP, INC. (ISG). NO
WARRANTY OR GUARANTEE IS IMPLIED. THE
CONTRACTOR SHALL VERIFY THE SIZES, LOCATIONS, AND
ELEVATIONS OF ALL EXISTING UTILITIES PRIOR TO
CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY
NOTIFY ENGINEER OF ANY DISCREPANCIES OR
VARIATIONS FROM PLAN.
9. THE CONTRACTOR IS TO CONTACT "IOWA ONE CALL" FOR
UTILITY LOCATIONS A MINIMUM OF 2 BUSINESS DAYS
PRIOR TO ANY EXCAVATION / CONSTRUCTION
(1-800-292-8989).
2-13-2025
24-30402
C0-10 TITLE
---- ---- C0-10
C0-10
CONSTRUCTION PLANS
CALHOUN COUNTY IOWA
1725 LAKE AVE. NORTH
STORM LAKE, IA 50588
PHONE: 712.732.7745
STORM LAKE OFFICE
TITLE
JAT
HPT
CDR
SHEET INDEX
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
270TH STREET
280TH STREET
DU
RA
NT
A
VE
NU
E
EL
KL
AN
D
AV
EN
UE
W
ES
T F
OR
K
CA
MP
C
RE
EK
Printed or typed name
(signature) (date)
License number
SEAL
WIO A
LI
CE
NS
ED
PROFESS IONAL ENGINEER
I hereby certify that this engineering document was prepared by me or under direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.
My license renewal date is December 31, Pages or sheets covered by this seal:
CALEB
RASMUSSEN
25713
CALEB RASMUSSEN
All Sheets
25713
2-13-2025
C0-10 TITLE
C0-20 NOTES AND QUANTITIES
C0-30 DETAILS
C0-31 DETAILS
C0-32 DETAILS
C0-33 DETAILS
C1-10 SITE RESTORATION PLAN
C2-10 EXISTING SITE - WATERSHED
C3-10 SITE PLAN
C3-20 INLET PLAN & PROFILE
C3-21 OUTLET PLAN & PROFILE
C4-10 GRADING PLAN
C4-20 CUT - FILL
C4-30 CROSS SECTION
LYTTON, 2 MILES
PROJECT LOCATION
SCALE IN FEET
500 1000
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, JUDGEMENT, AND BELIEF, THESE PLANS MEET THE APPLICABLE
NRCS STANDARDS AND APPLICABLE LAWS AND REGULATIONS.
TO THE BEST OF MY PROFESSIONAL KNOWLEDGE, JUDGEMENT,
BELIEF, THE PLANS MEET APPLICABLE NRCS STANDARDS.
ENGINEER'S SIGNATURE DATE
I HAVE REVIEWED AND AGREE WITH THE CONTENTS OF THE
PLAN AND SPECIFICATIONS AS PREPARED.
LANDOWNER SIGNATURE DATE
CONTRACTOR IS RESPONSIBLE FOR CALLING IOWA ONE CALL
ONE CALL TICKET NO.
IF A CULTURAL RESOURCE IS IDENTIFIED DURING
CONSTRUCTION, WORK WILL STOP IMMEDIATELY AND THE
LOCAL NRCS FIELD OFFICE WILL BE NOTIFIED.
I CERTIFY THAT THIS PRACTICE HAS BEEN CONSTRUCTED IN
ACCORDANCE WITH THE PLANS AND SPECIFICATIONS.
CONTRACTORS SIGNATURE DATE
ENGINEER'S REP. SIGNATURE DATE
IA NRCS JOB CLASS III
Printed or typed name
(signature) (date)
License number
SEAL
WIO A
LI
CE
NS
ED
PROFESS IONAL ENG INEER
I hereby certify that this engineering document was prepared by me or under direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Iowa.
My license renewal date is December 31, Pages or sheets covered by this seal:
SPENCER
DEAN PECH
P28161
SPENCER DEAN PECH
REVISIONS ON SHEETS C0-10, C0-20, C0-30, C0-31, C1-10, C3-10, AND C3-21
25713
8-19-2026
8-18-2026 REVISIONS FOLLOWING PRE-BID MEETING HLC8-18-2026 REVISIONS FOLLOWING PRE-BID MEETING HLC
30402-C0-DETAILS
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0- D
ET
AI
LS
.D
D
B Y:
L U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
C0-20
2-13-2025
24-30402
C0-20 NOTES AND QUANTITIES
---- ---- C0-20
CALHOUN COUNTY IOWA
NOTES AND
QUANTITIES
JAT
HPT
CDR
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
CONSTRUCTION NOTES:
GENERAL NOTES
1. ACCESS - CONTRACTOR IS TO ARRANGE ACCESS WITH LANDOWNER PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE TO SECURE PERMISSION OF THE
COUNTY ENGINEER TO CONSTRUCT TEMPORARY ACCESS IF NECESSARY.
2. EQUIPMENT STAGING: CONTRACTOR TO DESIGNATE EQUIPMENT STAGING AREA AT PRE-CONSTRUCTION MEETING.
2.1. REFER TO THE PLANS FOR FLOOD PLAIN EXTENTS. THE CONTRACTOR IS RESPONSIBLE FOR MONITORING WEATHER AND REMOVING EQUIPEMENT FROM THE
FLOODPLAIN IF AN ADVERSE EVENT IS EXPECTED.
3. WORK LIMITS ARE CONFINED TO THE EASEMENT AREA EXCEPT WHERE INDICATED ON PLANS. CONTRACTOR SHALL TRY TO MINIMIZE DISTURBANCE FOOTPRINT.
4. UTILITIES: CONTRACTOR IS RESPONSIBLE FOR CALLING IOWA ONE CALL (1-800-292-8989) AND MUST PROVIDE VERIFICATION (TICKET NO.) TO THE ENGINEER PRIOR
TO MOBILIZATION. CONTRACTOR RESPONSIBLE FOR PROTECTION OF ALL UTILITIES AND IS RESPONSIBLE TO VERIFY LOCATION/ELEVATION OF ALL UTILITIES IN WORK AREA PRIOR TO EXCAVATION. A DESIGN ONE CALL WAS PERFORMED ON DECEMBER 31, 2024.
4.1. EXPECTED WETLAND UTILITIES: NONE.
4.2. EXPECTED FIELD ENTRANCE UTILITIES:
4.2.1. MID-AMERICAN ELECTRIC
4.2.2. MID-AMERICAN GAS
4.2.3. WINDSTREAM COMMUNICATIONS
5. DEWATERING: CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING REASONABLE DRY WORKING CONDITIONS DURING CONSTRUCTION. ANY TEMPORARY
DEWATERING IS TO BE AT CONTRACTOR'S DISCRETION AND INCIDENTAL TO ITEMS OF WORK.
6. TOPSOIL STRIPPING (CS-IA-01):
a. STRUCTURE AND BORROW AREAS SHALL BE STRIPPED OF NO LESS THAN TWELVE (12) INCHES.
b. AREAS FOR TILE WORK SHALL BE STRIPPED NO LESS THAN TWELVE (12) INCHES.
c. ALL OTHER AREAS TO BE STRIPPED TO NINE (9) INCHES.
7. TOPSOIL STOCKPILE: CONTRACTOR IS RESPONSIBLE FOR SEGREGATION TOPSOIL FROM EXCAVATION SPOILS THROUGHOUT CONSTRUCTION. CONTRACTOR IS TO
DESCRIBE TOPSOIL MANAGEMENT AT PRECONSTRUCTION MEETING.
8. TOPSOIL SPREADING: ALL AREAS RECEIVING TOPSOIL DRESS SHALL BE UNDERCUT 6 INCHES AND TOPSOIL SHALL BE SPREAD AT LEAST 6 INCHES THICK TO THE
DESIGN SURFACE, OR AS INDICATED ON PLANS.
9. EARTHFILL: ALL STRUCTURAL EARTHFILL SHALL BE PLACED AND COMPACTED IN LOOSE LIFTS NO THICKER THAN NINE (9) INCHES. ENGINEER MAY DIRECT THINNER
LIFTS BASED ON AVAILABLE COMPACTION EQUIPMENT.
10. AREAS UNDER FILL SHALL BE SCARIFIED LIGHTLY BEFORE FIRST LIFT TO A DEPTH OF SIX (6) INCHES AND RECOMPACTED IN ACCORDANCE WITH SPECIFICATION
IA-23, SECTION 6, METHOD 1.
11. CONSTRUCT CORE TRENCH UNDER ENTIRE DIKE ALIGNMENT AT CENTERLINE.
12. TESTING: CONTRACTOR TO ENSURE ADEQUATE MOISTURE AND DENSITY THROUGHOUT CONSTRUCTION. COMPACTION IS TO BE PERFORMED IN ACCORDANCE
WITH SPECIFICATION IA-23 EARTHFILL. CONTRACTOR IS RESPONSIBLE FOR ENSURING SOILS MEET ADEQUATE MOISTURE REQUIREMENTS.
13. WEED CONTROL IA CS-06: CONTRACTOR IS REQUIRED TO CONTROL WEED GROWTH WITHIN THE WORK LIMITS AS NEEDED WITHIN THE CONSTRUCTION LIMITS, FOR
THE APPROVED CONSTRUCTION WINDOW.
14. RUBBISH DISPOSAL IA CS-01: ROCKS, FENCE, AND RUBBISH ENCOUNTERED WITHIN THE EASEMENT AREA ARE TO BE DISPOSED OF BY BURIAL OR OTHER
APPROVED MEANS. MISCELLANEOUS ROCKS AND RUBBISH ENCOUNTERED DURING EXCAVATION ARE TO BE INCLUDED FOR BURIAL AS WELL. A MINIMUM OF THREE
(3) FEET OF COVER OVER BURIED RUBBISH IS REQUIRED. CONTACT ENGINEER PRIOR TO REMOVING ANY FENCE.
15. WORKMANSHIP: CONTRACTOR SHALL PERFORM ALL WORK WITH CRAFTSMAN-LIKE APPEARANCE AND LEAVE NO TRASH/DEBRIS AFTER DEMOBILIZATION.
16. SAFETY - CONTRACTOR IS RESPONSIBLE FOR SAFETY ON THE WORK SITE, INCLUDING THE BRACING OF, SHORING OF, SHAPING OF, AND/OR USE OF TRENCH BOX IN
THE EXCAVATIONS. THIS INCLUDES KNOWLEDGE AND COMPLIANCE WITH ALL RULES AND REGULATIONS INTENDED TO PROTECT THE HEALTH AND SAFETY OF THE CONTRACTOR, ENGINEERS, AND OWNER'S PERSONNEL. ALL TRENCHING SHALL BE DONE ACCORDING TO OSHA STANDARDS FOR THE PROTECTION OF LIFE.
17. FLOODPLAIN: PROJECT WORK LIMITS RESIDE IN A MAPPED FLOODPLAIN. MATERIALS, EQUIPMENT, AND EXCESS SPOIL MAY NOT BE STOCKPILED OR STORED WITHIN THE FLOODPLAIN. FINAL GRADING SHOULD BE DONE TO ENSURE ANY SPOIL PLACEMENT AND FILL WITHIN THE FLOODPLAIN DOES NOT DEVIATE SIX (6) INCHES
FROM EXISTING GRADE.
18. VEGETATION CLEARING & TREATMENT: VEGETATION MANAGEMENT TO BE DETERMINED BASED ON CONSTRUCTION SCHEDULE AND AVAILABLE SEEDING WINDOWS.
CONTRACTOR IS EXPECTED TO BE ABLE TO PERFORM, MOWING/HAYING WITH REMOVAL (SUCH AS BIG ROUND BALES), CONTROL FIRE BURN, CHEMICAL BURN (BY LICENSED APPLICATOR), AND DISCING-HARROWING. FOR THE PURPOSES OF BIDDING, A CONTROL FIRE BURN, FOLLOWED BY 2 APPLICATIONS FOR CHEMICAL
TERMINATION, FOLLOWED BY LIGHT DISCING WITH DRAG HARROW FOLLOWER IS EXPECTED.
19. IDALS AND ISG DO NOT GUARANTEE THE WETLAND WILL FILL OR REMAIN FILLED WITH WATER.
TILE INSTALLATION
20. WORK LIMITS - OUTSIDE OF EASEMENT AREA, CONTRACTOR SHALL LIMIT CONSTRUCTION ACTIVITY TO WITHIN A 90 FOOT WIDE CORRIDOR ALONG THE LENGTH OF
THE TILE ALIGNMENTS AS SHOWN ON THE PLANS.
21. TILE INVESTIGATION - VERIFY LOCATIONS AND ELEVATIONS OF EXISTING TILE PRIOR TO CONSTRUCTION. TILE INVESTIGATION INCLUDES TIME NECESSARY TO
LOCATE AND DIG EXISTING TILES. EXPLORATION FOR DESIGN FOR TILE ENCOUNTERED, BUT NOT SHOWN ON THE PLANS WILL BE PAID UNDER THIS ITEM.
22. CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL TILE FOUND DURING THE TILE INVESTIGATION AND DURING WETLAND EXCAVATION.
23. CONTRACTOR SHALL MAKE EFFORT TO SEGREGATE ORGANIC TOPSOIL TO MINIMUM DEPTH OF 12 INCHES FOR ALL TILE WORK OUTSIDE OF EXCAVATION AND FILL
AREAS.
24. FIELD TILE CONNECTIONS - CONNECTIONS TO INTERCEPTED FIELD TILE 12" DIAMETER AND LESS SHALL BE MADE AND ENCASED IN A PORTLAND CEMENT
CONCRETE (PCC) COLLAR AT LEAST TWELVE (12) INCHES WIDE AND FOUR (4) INCHES THICK, CONTINUOUS AROUND THE JOINTS. ALTERNATIVE CONNECTIONS MUST
BE APPROVED BY THE ENGINEER.
25. ALL TILE SHALL BE BLINDED WITH NATIVE SOILS OR ASTM CLASS 2 MATERIAL WHEN REQUIRED IN REGULAR INTERVALS AS INSTALLATION PROCEEDS. TILE FOUND TO BE FLOATING IN THE TRENCH SHALL BE REMOVED, THE TRENCH DEWATERED, AND THE TILE IMMEDIATELY INSTALLED AND BLINDED.
26. TILE SHALL BE INSTALLED ACCORDING TO MANUFACTURERS' SPECIFICATIONS USING EITHER A SPOON TRENCH CONFORMING TO THE CURVE OF THE PIPE UP TO THE HAUNCH/SPRING LINE. FOR A BLAT BOTTOM TRENCH THE PIPE SHALL BE BEDDED AND BACKFILLED WITH AGGREGATE TO THE SPRING LINE.
RISER INLET & CONTROL STRUCTURE NOTES
27. STRUCTURE SHOP DRAWINGS ARE REQUIRED FOR ENGINEER'S REVIEW AND APPROVAL BEFORE FABRICATION OF STRUCTURES, REFER TO INSPECTION TABLE.
28. DRAIN BASIN TO BE CUSTOM MANUFACTURED ACCORDING TO PLAN DETAILS.
29. DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212 FOR CORRUGATED HDPE.
30. USE ASTM CLASS 2 MATERIAL TO BED AND LEVEL STRUCTURE. LOOSE EARTH FILL IS NOT PERMITTED AS BACKFILL TO LEVEL THE STRUCTURE.
31. CHECK TO ENSURE STRUCTURE IS LEVEL PRIOR TO BACKFILLING. PLACE BACK FILL MATERIAL AROUND STRUCTURE IN 6" LIFTS AND COMPACT BY HAND. DO NOT
USE POWERED EQUIPMENT.
32. BACKFILL AROUND STRUCTURES SHALL BE COMPACTED BY HAND. NO MECHANICAL PACKING METHODS MAY BE USED.
ITEMS OF WORK TABLE
INSPECTION TABLE
CONSERVATION PRACTICE STANDARDS
PRIMARY
656: CONSTRUCTED WETLAND
SUPPORTING
327: CONSERVATION COVER
342: CRITICAL AREA PLANTING
356: DIKE OR LEVEE
587: STRUCTURE FOR WATER CONTROL
606: SUBSURFACE DRAIN
620: UNDERGROUND OUTLET
8-13-2026 ADD SILT FENCE TO IOW & INSPC HLC
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0- D
ET
AI
LS
.D
D
B Y:
L U
KE
.C
AR
PE
N
TE
C0-30
2-13-2025
24-30402
C0-30 DETAILS
---- ---- C0-30
CALHOUN COUNTY IOWA
DETAILS
JAT
HPT
CDR
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
SECTION VIEW
PLAN VIEW
NOTE:
NUMBER OF RODS AND SIZE OF GRATE
VARY W/ SIZE OF TILE INTAKES. PAINT
WITH TWO (2) COATS RUST INHIBITING
PAINT FOLLOWING FABRICATION.
CMP SLOTTED INTAKE RISER
NTS
BEEHIVE INLET GRATE (STEEL BARS)
NTS
9040.110
RIP RAP FOR PIPE OUTLET
ONTO FLAT GROUND
SUDAS Standard Specifications
Section A-A
To e of S lo pe min.
8'
8'
4'
T
Slope = 0%
Stable Ground
Thickness, T Construct notch at end of apron.
Depth = 2T
PLAN
PROFILE
4'
4'
1'
18" DIA CMP
TOP VIEW
3 F T
POOL EL=1181.50
I=1178.00
WATER CONTROL STRUCTURE
NTS
18" MIN.12" - 18"
2'
78"
2" MIN.
7.25' MIN.
8' MAX.
ELEV = 1184.50
1/4" STEEL ROD MINIMUM
BEEHIVE INLET GRATE
(SEE DETAIL)
SLOTTED PERFORATIONS
2" X 6" SLOTS SPACED 8" HORIZ. & 6"
VERT. OFFSET COLUMNS 4" AND 8"
FROM TOP OF STRUCTURE
30° TYPICAL
SEAM
℄ SLOT
2' WELDED STUB, 10" DIA.
SURROUND
RISER WITH 16
TON EROSION
STONE
CORRUGATED
ALUMINIZED 16
GAUGE METAL
RISER W/
PERFORATIONS
CONNECT TO HDPE WITH
REINFORCED CONCRETE COLLAR OR
MANUFACTURED COUPLER FOR
DISSIMILAR MATERIALS
(BUTT JOINT)
BERM
SLOPE
EXISTING GROUND
54" CMP RISER
8" CONCRETE BASE
15" CMP 15" CMP
10" HDPE10" HDPE
2-CHAMBER WCS
LOCKABLE LID
#4 DEFORMED BAR @ 12" OCEW
EMBED 1 1/2 CORRUGATIONS
2'
24"
SURROUND WITH 4 TN CRUSHED
STONE, ASTM D2321
CLASS 2 MATERIAL
HDPE SPOON TRENCH
NTS
PIPE IDUNDISTURBED SOIL
BACKFILL WITH TRENCH MATERIAL
SPOON EXTENTS
PLACE 1.5 TN/100LF ASTM CLASS 2
MATERIAL (MECHANICALLY
COMPACT TO TOP OF PIPE IN 6"
LIFTS), WHERE SHOWN ON PLANS
NOTES:
1. ASTM CLASS 2 AND BACKFILL SHALL BE INCIDENTAL TO CONSTRUCTION.
2. SPOON DIMENSIONS SHALL COMPLY WITH PIPE MANUFACTURER'S SPECIFICATIONS.
3. THE FIRST LIFT OF BACKFILL SHALL BE PLACED WITH AN EXCAVATOR WITH NO MORE
THAN 2' OF DROP.
4. CRUSHED CONCRETE, MEETING THE REQUIREMENTS OF ASTM CLASS 2 MATERIAL
MAY BE USED. ENGINEER TO AUTHORIZE USE, PRIOR TO MATERIAL STAGING.
FIL
L H
EI
GH
T (V
AR
IE
S)
Modified for project use.
CONNECT TO HDPE WITH
REINFORCED CONCRETE COLLAR OR
MANUFACTURED COUPLER FOR
DISSIMILAR MATERIALS
CONNECT TO HDPE WITH
REINFORCED CONCRETE COLLAR OR
MANUFACTURED COUPLER FOR
DISSIMILAR MATERIALS
INLET AND
OUTLET
INVERT=1177.55
NOTE:
DO NOT USE ENGINEERING FABRIC TO
INSTALL RISER OR PLACE SURROUND
STONE.
8"
SUPPORT STUB ON CONCRETE BASE
6'
18"
PLAN VIEW
ENSURE INTERNAL
STRUCTURE LID
CAN BE REMOVED
WITHOUT
REMOVING
EXTERNAL
STRUCTURE LID
LID HINGE
SECTION VIEW
6" MIN6" MIN
NOTE: IN LIEU OF FABRIC USE 1.5TN ASTM CLASS 2, 6 INCH THICK
PLACE 6" OF CRUSHED ROCK
42" CONCRETE PAD
8-19-2026 ADDED CONCRETE BASE TO SLOTTED INTAKE RISER, ADD GAUGE
TO SLOTTED INTAKE RISER CALL OUT
HLC
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0- D
ET
AI
LS
.D
D
B Y:
L U
KE
.C
AR
PE
N
TE
C0-31
2-13-2025
24-30402
C0-31 DETAILS
---- ---- C0-31
CALHOUN COUNTY IOWA
DETAILS
JAT
HPT
CDR
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
OPTION 1 WCS SPECIFIC:
1. FLASH BOARDS SHALL BE PVC.
2. ALL RIVETS SHALL BE STAINLESS STEEL.
3. FLASHBOARD CHANNEL SHALL BE ANODIZED ALUMINUM.
4. FLASHBOARDS WILL REMAIN IN STRUCTURE DURING INSTALLATION.
5. FLASHBOARDS SHALL BE LUBRICATED UPON REMOVAL.
WCS GENERAL NOTES:
1. TOOL TO REMOVE FLASHBOARDS/ACTUATE VALVE IS TO REMAIN IN WCS FOLLOWING INSTALLATION.
2. FOR INLET ADAPTER, MAX SIZE IS TWO SIZES DOWN FROM STRUCTURE SIZE (I.E. 8" ADAPTER ON 12"
STRUCTURE.
3. CHECK TO ENSURE THE STRUCTURE IS LEVEL PRIOR TO BACKFILLING. PLACE THE BACKFILL MATERIAL AROUND
THE STRUCTURE IN 6" LIFTS AND COMPACT BACKFILL BY HAND ONLY. DO NOT USE POWERED EQUIPMENT TO
COMPACT THE BACKFILL.
4. WATER CONTROL STRUCTURES WILL HAVE A MINIMUM OF 20' NONPERFORATED PIPE BETWEEN WATER
CONTROL STRUCTURE AND DITCH.
5. ONE ANTISEEP COLLAR WILL BE INSTALLED ON THE 20' OF NONPERFORATED PIPE BETWEEN THE WATER
CONTROL STRUCTURE AND DITCH.
6. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF WATERTIGHT TEE, INCLUDING MINIMUM
ANGLE OF SEPARATION.
7. WATER TIGHT TEE, QUANTITY, AND INSTALLATION METHOD DEPENDENT ON WCS MANUFACTURER.
8. FINAL CONFIGURATION OF WATER CONTROL STRUCTURES WILL BE DETERMINED BY AVAILABILITY FROM THE
MANUFACTURER.
9. COMPONENTS OF WATER CONTROL STRUCTURES MAY BE PRICED SEPARATELY DEPENDING ON THE SUPPLIER.
NRCS NOTES*:
1. WATER CONTROL STRUCTURE (WCS) MATERIALS AND INSTALLATION SHALL BE IN CONFORMANCE WITH IOWA
NRCS CONSTRUCTION SPECIFICATION (CS) IA-45, PLASTIC (PVC, PE) PIPE.
2. CONNECTING PIPE MATERIALS AND INSTALLATION SHALL BE IN CONFORMANCE WITH CS IA-45; IA-46, TILE
DRAINS FOR LAND DRAINAGE; IA-51, CORRUGATED METAL PIPE CONDUITS; OR IA-52, STEEL PIPE CONDUITS.
3. WCS SHALL BE FABRICATED OF PVC WITH INTEGRAL UPSTREAM AND DOWNSTREAM WATER-TIGHT COUPLING
CONNECTIONS, CORROSION-RESISTANT STOP BOARDS, ALUMINUM EXTRUSIONS AND STAINLESS STEEL FASTENERS AND APPURTENANCES. ACCEPTABLE MODELS INCLUDE AGRI DRAIN, NYLOPLAST, OR APPROVED
EQUAL.
4. WCS SHALL PROVIDE FLOW CAPACITY EQUAL TO OR GREATER THAN THAT OF ADJACENT PIPE UNDER
EXPECTED FLOW CONDITIONS.
5. STOP BOARDS SHALL PROVIDE A WATER-TIGHT SEAL UNDER 4 FT OF PRESSURE HEAD (MIN.).
6. IN SITUATIONS WHERE WATER LEVELS HIGHER THAN MAXIMUM DESIGN ELEVATION WOULD IMPACT
NEIGHBORING PROPERTIES OR OTHER ASPECTS OF THE SITE DESIGN, CONSIDER A CUSTOM-ORDER BOX
WHICH LIMITS EXTENT OF STOP BOARD TRACKS TO THE MAXIMUM DESIGN WEIR ELEVATION.
7. STOP BOARD REMOVAL TOOL SHALL BE PROVIDED.
8. AS AN ALTERNATIVE TO A STOP BOARD STRAIGHT WEIR STRUCTURE, A CIRCULAR INNER STANDPIPE MAY BE
PROVIDED WHICH MEETS THE DESIGN FLOW REQUIREMENTS, WITH APPROVAL OF THE ENGINEER (NYLOPLAST
STANDPIPE WCS OR EQUAL).
9. ALL CONNECTIONS SHALL BE WATER-TIGHT.
10. STRUCTURE LID SHALL BE PROVIDED WITH LOCKING MECHANISM.
11. BACKFILL AROUND THE WCS SHALL MEET THE REQUIREMENTS OF CS IA-45. NORMAL STOP BOARD OPERATION
SHALL BE VERIFIED FOLLOWING BACKFILL.
12. MARK LOCATION OF EACH STRUCTURE USING POST OR MANUFACTURED MARKER FLAG FOR SAFETY IN THE
FIELD *FROM USDA-NRCS IA-1530 STANDARD DRAWING
STRIKEOUT ITEMS ARE NOT REQUIRED FOR THIS SET
FLOW FLOW
WATER TIGHT FITTING
FOR UPSTREAM
CONNECTING PIPE
LID TO BE FURNISHED WITH STRUCTURE
WATER TIGHT FITTING
FOR DOWNSTREAM
CONNECTING PIPE
ALL FLASH BOARDS SHALL BE FITTED
WITH LIFTING HOOKS AND EDPM SEAL
(NOT SHOWN)
EXTRA FLASH BOARDS TO BE
PULLED ABOVE SET WEIR ELEVATION
FOR STORAGE
FLASH BOARD GUIDE CHANNEL
OPTION 1
WATER CONTROL STRUCTURE DETAIL
NTS
AUXILIARY SPILLWAY
WITH CONCRETE EROSION MAT
NTS
WETLAND NWL = 1181.50
EXISTING GROUND
PROPOSED GRADE FLOW TIED CONCRETE BLOCK EROSION MAT
INSTALLED PER MANUFACTURER RECOMMENDATIONS FOR
PERPENDICULAR FLOW FOR SPILLWAYS AND OVERFLOWS
8:1
9040.119
SILT FENCE
SUDAS Standard Specifications
Foreslope Back slo pe
Post Spacing
(5'-0" max.)
Post Spacing
(5'-0" max.)
Fabric
Variable (20'-0" for a normal 10'-0" wide ditch.)
2" min.
20" min.
Post
Wire or Cable Ties
Insert 12 inches of fabric a minimum of 6 inches deep (fabric may be folded below the ground line).
TYPICAL SILT FENCE DITCH CHECK
ATTACHMENT TO POST
8-13-2026 ADDED SILT FENCE DETAIL HLC
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0- D
ET
AI
LS
.D
D
B Y:
L U
KE
.C
AR
PE
N
TE
C0-32
2-13-2025
24-30402
C0-32 DETAILS
---- ---- C0-32
CALHOUN COUNTY IOWA
DETAILS
JAT
HPT
CDR
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
9040.105
WATTLE
SUDAS Standard Specifications
Disturbed Area
Area to be Protected
Space as specified in the contract documents.
4' -0
" m ax
Wattle
Dire ctio n of F low
3'-0"
4'-0" max.
Stakes
2-4" Trench
Compact trench spoil against uphill side of wattle.
9" (nominal) dia.
or as specified.
Joint Wrap
Turn uphill.
9040.111
RIP RAP APRON FOR PIPE
OUTLET INTO CHANNEL
SUDAS Standard Specifications
Top of Bank
Stable Channel
Edge of Channel
Top of Bank
Section A-A
W id th , W
T min.
Slope = 0%
Construct notch at end of apron.
Depth = 2T.
CROSS-SECTION
Thickness, T
PROFILE
PLAN
4'
10' 10'
6:1
1:1
8'
4'
CENTERLINE
TOPSOIL SPREAD
TOPSOIL STRIPPING
CORE TRENCH
EARTHEN DIKE
DIKE AND CORE TRENCH
TYPICAL SECTION
NTS
PROPOSED GROUND
EXISTING
GROUND
TRENCH DAM
NTS
2'
NOTES:
1. BETONITE SHALL BE EITHER IN
GRANULAR OR CHIP FORM, WITH A
MAXIMUM NOMINAL SIZE OF 3
8"
MIXED WITH NO MORE THAN 80%
SAND (C33).
2. THE TRENCH DAM (ANTI-SEEP COLLAR)
SHALL EXTEND AT LEAST 6 INCHES
BEYOND THE STANDARD PIPE
TRENCH.
3. PLACEMENT OF THE COLLAR SHALL NOT
BE WITHIN 2 FEET OF A PIPE JOINT.
4. MINMUM DISTANCE FROM EDGE OF PIPE
IS 3x PIPE DIAMETER OR 6" BEYOND
TRENCH EXTENTS, WHICHEVER IS
GREATER, TYP
BENTONITE/SAND MIX (25:75)
2.5'
SEE NOTE 4
2.5'
SEE NOTE 410"
CARRIER PIPE
2'
MI
N 2'
PLACE 6" OF CRUSHED ROCK
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
0- D
ET
AI
LS
.D
D
B Y:
L U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C0-33
C0-33 DETAILS
24-30402
2-13-2025
C0-33
IOWACALHOUN COUNTY
CDR
HPT
JAT
DETAILS
WIDTH VARIES TO TOP WIDTH OF
EMERGENCY OVERFLOW
MINIMUM 6" OF FREEBOARD
EXTEND TIED CONCRETE BLOCK MAT
MINIMUM 5'
BELOW NPE
NPE
IF EDGE OF TIED CONCRETE BLOCK MAT IS
EXPOSED TO SHEET FLOW,
RECESS THE OUTSIDE 2
BLOCKS INTO THE SLOPE AT
45 DEGREE ANGLE
EDGE NOT
EXPOSED TO
FLOW DOES
NOT NEED TO
BE RECESSED
UP CHANNEL MAT
DOWN CHANNEL MAT
FLOW
5' BELOW NPE (FOR
EMERGENCY
SPILLWAYS SEE
CONSTRUCTION
NOTE #3)
OVERFLOW DIKE
OVERFLOW ELEVATION
OUTFALL CHANNEL
FLOW
6" STANDARD
UNDERLAYMENT EXTENSION
12" GEOGRID EXTENSION
FLO
W
MAT SEAM PARALLEL
WITH FLOW
PANELWITH
GEOGRID AND STANDARD
UNDERLAYMENT EXTENSIONS
18" U-ANCHORS OR STAINLESS STEEL
ZIP TIES INSTALLED IN 2' INCREMENTS
ACROSS OVERLAP. INSTALL ANCHOR
BEHIND FIRST ROW BLOCK
EMERGENCY SPILLWAY - ISOMETRIC VIEW
OVERFLOW DIKE - PROFILE VIEW
1. OVERLAP METHOD FOR SEAMS PERPENDICULAR TO FLOW 2. OVERLAP METHOD FOR SEAMS PARALLEL TO FLOW
TIED CONCRETE BLOCK MAT - OVERFLOW CHANNEL PARALLEL TO FLOW
CONSTRUCTION NOTES:
1. AN ENGINEER OR MANUFACTURERS REPRESENTATIVE SHALL BE ONSITE FOR THE START OF THE INSTALLATION.
2. ALL SUBGRADE SURFACES PREPARED FOR PLACEMENT OF MATS SHALL BE SMOOTH AND FREE OF ALL ROCKS, STICKS, ROOTS, OTHER PROTRUSIONS, OR DEBRIS OF ANY KIND. THE
PREPARED SURFACE SHALL PROVIDE A FIRM UNYIELDING SUBGRADE FOR THE MATS.
3. PRIOR TO THE TIED CONCRETE BLOCK MAT INSTALLATION SEED AND FERTILIZE SUBGRADE WITH SITE SPECIFIC SEED MIX IN ACCORDANCE WITH THE PROJECT PLANS AND SPECIFICATIONS.
4. MAT SHALL EXTEND 5' BELOW NORMAL POND ELEVATION. (FOR EMERGENCY OVERFLOW INSTALLATIONS EXTEND THE MAT 3' DOWN THE INSIDE FACE OF THE OVERFLOW DIKE.)
5. INSTALL TIED CONCRETE BLOCK MAT ROLLS. MANUFACTURER RECOMMENDS INSTALLING THE WIDEST MAT POSSIBLE FOR SPILLWAY APPLICATIONS.
5.1. FOR WIDTHS WIDER THAN 16', INSTALL 15.5' WIDE MATS WITH GEOGRID AND STANDARD UNDERLAYMENT EXTENSIONS. INSTALL ADJACENT MAT OVER THE 12" GEOGRID AND 6" STANDARD UNDERLAYMENT EXTENSIONS OF THE ADJACENT MATS. ENSURE THE GEOGRID AND STANDARD UNDERLAYMENT EXTENSIONS ARE LAYING FLAT ON THE SUBGRADE BEFORE INSTALLING ADJACENT MAT OVER THE EXTENSIONS. INSTALL #3 REBAR 18" U-ANCHORS IN 2' INCREMENTS ACROSS THE GEOGRID AND STANDARD EXTENSION ABUTMENT. INSTALL ANCHORS PERPENDICULAR TO THE FLOW DIRECTLY BEHIND FIRST ROW OF BLOCKS ON THE ADJACENT MAT.
5.2. FOR ADDITIONAL SECTIONS OF MAT, OVERLAP THE DOWNSTREAM SECTION 18" WITH UPSTREAM SECTION OF MAT. PRIOR TO INSTALLING OVERLAP, FLIP UPSTREAM MAT BACK 24". EXCAVATE 2.25" OF SOIL 18" FROM THE END OF THE UPSTREAM MAT. DOWNSTREAM SECTION IS THEN LAID IN THE SHALLOW TRENCH. RETURN AND TAMP SOIL OVER INITIAL EDGE AND SEED AREA. FLIP END OF UPSTREAM MAT OVER THE SOIL COVERED INITIAL LEADING EDGE. SEED AND FERTILIZE SOIL INFILL PRIOR TO FLIPPING END OF UPSTREAM MAT OVER THE SOIL COVERED INITIAL LEADING EDGE OF DOWNSTREAM MAT. SECURE PERPENDICULAR OVERLAP SEAMS BY INSTALLING #3 REBAR - 18" U
ANCHORS PERPENDICULAR TO FLOW IN 2' INCREMENTS.
6. AT THE END OF THE ARMORED SPILLWAY, EMBED THE MAT 18" IN A TERMINATION TRENCH. FILL AND COMPACT TERMINATION TRENCH WITH SUITABLE FILL. (AS SPECIFIED BY EOR.)
SEED AND FERTILIZE PREPARED
SUBGRADE PRIOR TO
INSTALLING TIED CONCRETE BLOCK MAT
STANDARD
TIED CONCRETE BLOCK MAT
STANDARD
ADJACENT
TIED CONCRETE BLOCK MAT PANEL
FL
OW
SOIL INFILL AND SEED
OVERLAP SEAM
OVERLAP SEAM: INSTALL ENDING
EDGE OF UP CHANNEL MAT 18"
OVER THE LEADING EDGE OF THE
DOWN CHANNEL MAT. SECURE
OVERLAP SEAM BY INSTALLING
18" U-ANCHORS IN 2'
INCREMENTS BEHIND THE FIRST
BLOCK OF THE UP CHANNEL MAT
CURLEX II ECB
5-PICK LENO
WEAVE
STANDARD UNDERLAYMENT
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
GRODAHL FARMS INC
XXXXXXXX
SF
SF
SF
SF
SF
SF
SF SF SF
SF
SF
SF
SF
SF SF SF SF
SF
SF
SF
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C1-SWPPP
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
1-
SW
PP
P.
D W
G S
AV
ED
B Y:
L U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C1-10
C1-10 SITE RESTORATION PLAN
SCALE IN FEET
50 100
TOP OF BANK (TYP)
WEST FORK CAMP CREEK
C1-10
2-13-2025
24-30402
SITE
RESTORATION
PLAN
JAT
HPT
CDR
CALHOUN COUNTY IOWA
EROSION CONTROL LEGEND
SYMBOL DESCRIPTION
RIP RAP, CLASS E OR EROSION STONE
BUFFER SEEDING
STRUCTURE, WATERWAY, & CHANNEL SEEDING
COVER CROP SEEDING
STRAW WATTLE
PURPOSED SILT FENCE
EXISTING CONTOUR (MINOR INTERVAL)
EXISTING CONTOUR (MAJOR INTERVAL)
PROPOSED CONTOUR (MINOR INTERVAL)
PROPOSED CONTOUR (MAJOR INTERVAL)
TEMPORARY WORK LIMITS
APPROXIMATE PARCEL LINE (TYP)
INSTALL NATIVE
BUFFER SEED MIX
3.0 ACRES
INSTALL CRIMPED STRAW
MULCH OVER DIKE
0.6 ACRES
STRAW WATTLE, 50FT EACH
INSTALL WATERWAY SEEDING,
0.2 ACRES
FINAL RESTORATION OF CROP GROUND
OUTSIDE EASEMENT AREA TO BE
DETERMINED DURING CONSTRUCTION
COVER CROP SEEDING
1.2 ACRES
INSTALL 397 LF SILT FENCE
SF
INSTALL 15 LF SILT FENCE
INSTALL 453 LF SILT FENCE
ADDED SILT FENCE OUTLINES AND ANNOTATIONS HLC8-13-2026
INSTALL 460 LF SILT FENCE
WILLIAMS, ROBERT R
GRODAHL FARMS INC
GRODAHL FARMS INC
39.15
RILEY, MINDY ANN
GRODAHL FARMS INC
GRODAHL FARMS INC
XXXXXXXX
TEMPORARY ENTRANCE
CONSTRUCTION ACCESS
(25FT ASSUMED WIDTH) TO
UTILIZE GRASSED WATERWAY
ERODING BANK MAY WARRANT
ENCROACHING INTO CROP
GROUND TO MAINTAIN ACCESS
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C2-EX-SITE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
2-
EX
-S
IT
E.
D
W G
S
AV
ED
B
Y:
O
W
EN
.O
EL
TJ
EN
BR
U
N S
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C2-10
C2-10 EXISTING SITE - SITE ACCESS
SCALE IN FEET
100 200
EXISTING WATERSHED
EXISTING 12" HDPE TILE (TYP)
C2-10
2-13-2025
24-30402
EXISTING SITE -
SITE ACCESS
JAT
HPT
CDR
CALHOUN COUNTY IOWA
270TH STREET
APPROXIMATE PARCEL LINE (TYP)
SITE ACCESS TO BE DECOMPACTED AND RESEEDED
WITH STRUCTURE, WATERWAY, & CHANNEL SEEDING.
0.8 ACRES ASSUMED TO BE RESTORED
GRODAHL FARMS INC
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100
FP100FP100FP100
FP100FP100FP100FP100FP100FP100
FP
FP
FP
FP
FP
FP
FP
FP
FP
FP
FP
FP100 FP100 FP100
XXXXXXXX
8'
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C3-SITE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
3-
SI
TE
.D
W G
S
AV
ED
B
Y:
L
U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C3-10
C3-10 SITE PLAN
SCALE IN FEET
50 100
CONTAINMENT DIKE
TOP ELEV = 1183.0
6:1 SIDE SLOPES
EDGE OF FIELD (TYP)
TOP OF BANK (TYP)
PROPOSED CONTOUR (TYP)
EXISTING 12" HDPE TILE (TYP)
EASEMENT AREA
NORMAL POOL
ELEV = 1181.5
AREA = 2.35 ACRES
WATER CONTROL STRUCTURE
10' SUBMERGED BERM (TYP)
EXCAVATED AREA
AUXILIARY SPILLWAY
INSTALL 2,750 SF OF TIED CONCRETE BLOCK MATTING,
2 FT DIMENSIONAL OVERRUN INCLUDED FOR
MANUFACTURE VARIABILITY
WEST FORK CAMP CREEK
UNSTABLE BANK
FAILED TILE OUTLET
MODELED FLOODPLAIN EXTENTS
SPOIL WASTING AREA.
ALL SPOIL MUST BE PLACED
OUTSIDE OF FLOODPLAIN.
C3-10
2-13-2025
24-30402
SITE PLAN
JAT
HPT
CDR
CALHOUN COUNTY IOWA
DIVERTED TILE
SEE SHEET C3-20
PRINCIPAL SPILLWAY
SEE SHEET C3-21
BERM STORAGE AREA
ELEV = 1182.4
SLOTTED RISER
SEE SHEET C3-21
TEMPORARY WORK LIMITS
APPROXIMATE PARCEL
LINE (TYP)
CORRECTED EASEMENT ANNOTATION/ SITE CHARACTERISTIC
TABLE VALUE HLC8-13-2026
GRODAHL FARMS INC
0+001+002+003+004+005+006+00
118611871188
119011911192119311941195119611971198
119611971198
11811183
0+00
.5
.5
0+50
.3
.8
1+00
.5
.1
1+50
.8
.5
2+00
.8
.8
2+50
.6
.2
3+00
.9
.5
3+50
.8
.9
4+00
.0
.2
4+50
.5
.6
5+00
.5
.9
5+50
.3
.3
6+00
.7
.6
6+50
INSTALL 15" CMP
WITH FES & ANIMAL GUARD
20 LF @ 0.69%
STA: 0+00 TO 0+20
INSTALL 12" DUAL WALL HDPE
581 LF @ 0.69%
STA: 0+20 TO 6+01
ST
A
= 0 +0
0.0
EL
EV
.50
ST
A
= 0 +2
0.0
EL
EV
.64
ST
A
= 6 +0
0.9
EL
EV
.65
NOTE:
XXXX.X - EXISTING GROUND L
XXXX.XX - PROPOSED TILE GRADE
C
EXISTING GROUND
NWL=1181.5'
ASTM CLASS 2 BACKFILL
STA: 2+00 TO 4+40
DISSIMILAR PIPE CONNECTION
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C3-PROFILE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
3-
PR
O
FI
LE
.D
W G
S
AV
ED
B
Y:
J
ES
SE
.C R
U
TC
H
ER
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C3-20
C3-20 INLET PLAN & PROFILE
SCALE IN FEET
50 100
EXISTING 12" HDPE TILE (TYP)
FIELD VERIFY LOCATION AND DEPTH;
CONNECT TO EXISTING TILE AND CAP
DOWNSTREAM, INSTALL 12" CPT @0.69%MIN
OUTLET ELEV = 1182.5
10 TN OF RIPRAP
(SUDAS 9040.110)
SEE SHEET C0-30
C3-20
2-13-2025
24-30402
INLET PLAN &
PROFILE
JAT
HPT
CDR
CALHOUN COUNTY IOWA
GRODAHL FARMS INC
8'
0+001+001+73
118611871188
119011911192119311941195119611971198
11811183
0+00
.9
.0
0+50
.3
.5
1+00
.6
.1
1+50
.7
.7
2+00
.5
INSTALL 12" CMP
WITH FES & ANIMAL GUARD
20 LF @ 1.16%
STA: 0+00 TO 0+20
INSTALL 10" DUAL WALL HDPE
(NON-PERF)
153 LF @ 1.16%
STA: 0+20 TO 1+73
ST
A
= 0 +0
EL
EV
.00
ST
A
= 0 +2
EL
EV
.23
ST
A
= 1 +7
EL
EV
.00
NOTE:
XXXX.X - EXISTING GROUND L
XXXX.XX - PROPOSED TILE GRADE
C
WCS
R=1184.50 I=1177.55 (10'') I=1177.55 (10'')
SLOTTED 18" CMP
RISER
R=1181.00 I=1178.00 (10'')
1183.00
8.0
1178.50
NWL=1181.5'
TRENCH DAM
WATER
LEVEL
04/2024 1176.83
DISSIMILAR PIPE
CONNECTION
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C3-PROFILE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
3-
PR
O
FI
LE
.D
W G
S
AV
ED
B
Y:
L
U
KE
.C
AR
PE
N
TE
R
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C3-21
C3-21 OUTLET PLAN & PROFILE
SCALE IN FEET
50 100
TOP OF BANK (TYP)
INSTALL 5TN CLASS E RIPRAP
(SEE SHEET C0-32)
2-CHAMBER, 10"x6' WATER CONTROL STRUCTURE
WITH 54" DIA CMP SLEEVE WITH GRATED LID
CMP RIM ELEV = 1185.0
SLOTTED 18" CMP RISER
RIM ELEV = 1181.0
INVERT ELEV = 1178.0
SEE SHEET C0-30
TRENCH DAM
SEE SHEET C0-32
C3-21
2-13-2025
24-30402
OUTLET PLAN &
PROFILE
JAT
HPT
CDR
CORRECTED PIPE TO "DUAL WALLED"8-13-2026 HLC
GRODAHL FARMS INC
XXXXXXXX
1178 8'
118811891190
11921193119411951196119711981199120012011202120312041205
82 11
83 11 84 11
85 11 86 11
87 11 88 11
89 11 90 11
1181 1180
11811182
-8:1
-6:
-0.2%
-1.1%
-3.
8%
-2.2%
-4.
1%
-5.
3%
-2.2%
-9.3%
-4:1
-4:1
-6:1
-5:1
-2.
5%
10'
1.9
1.0
1.0
2.5
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C4-GRADE
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
4- G
R
AD
E.
D
W G
S
AV
ED
B
Y:
H
AL
EY
.T O
M S
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C4-10
C4-10 GRADING PLAN
SCALE IN FEET
50 100
CONTAINMENT DIKE
TOP ELEV = 1183.0
6:1 SIDE SLOPES
EDGE OF FIELD (TYP)
TOP OF BANK (TYP)
EXISTING CONTOUR (TYP)
PROPOSED CONTOUR (TYP)
BERM STORAGE AREA
ELEV = 1182.4
NORMAL POOL
ELEV = 1181.5
10' SUBMERGED BERM (TYP)
EXCAVATED AREA
WEST FORK CAMP CREEK
SPOIL WASTING AREA.
C4-10
2-13-2025
24-30402
GRADING PLAN
JAT
HPT
CDR
TEMPORARY WORK LIMITS
GRODAHL FARMS INC
XXXXXXXX
1178 8'
871188
118911901191
1181 1180
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C4-CUTFILL
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
4- C
U
TF
IL
L.
D W
G S
AV
ED
B Y:
H
AL
EY
.T
O M
S
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
---- ---- C4-20
C4-20 CUT - FILL
SCALE IN FEET
50 100
CONTAINMENT DIKE
TOP ELEV = 1183.0
6:1 SIDE SLOPES
EDGE OF FIELD (TYP)
TOP OF BANK (TYP)
NORMAL POOL
ELEV = 1181.5
AREA = 2.35 ACRES
10' SUBMERGED BERM (TYP)
EXCAVATED AREA
WEST FORK CAMP CREEK
SPOIL WASTING AREA.
C4-20
2-13-2025
24-30402
CUT - FILL
JAT
HPT
CDR
CALHOUN COUNTY IOWA
LEGEND
SYMBOL DESCRIPTION MINIMUM ELEVATION MAXIMUM ELEVATION VOLUME
AREA OF FILL 0.10 2.67 3,122 CY
BALANCE LINE -0.10 0.10 567 CY
AREA OF CUT -3.18 -0.10 3,089 CY
TOP OF BERM
ELEVATIONTEMPORARY WORK LIMITS
G
RO
DA
HL
F
AR
M S
IN
C
W
IR
TJ
ER
S, P
AT
RI
CI
A
M L
E
X X
X X
8'
1181 1182
0 1 2 3 4 5 5
118111
21179
SE
CT
IO
N
A- A
SE
CT
IO
N
A- A
SECTION A-A
-0+50 0+00
.3
0+50
.6
.1
1+00
.4
.1
1+50
.9
.0
2+00
.0
.9
2+50
.3
.7
3+00
.7
.4
3+50
.7
.1
4+00
.6
.8
4+50
.2
.6
5+00
.4
5+50 6+00
10' 10' 8'
EXISTING GROUND
PROPOSED GROUND
6:1
4:1
6:1
6:14:1
NWL=1181.5'
1181.0'1181.0'
1183.0'
NOTE:
XXX.X - EXISTING GROUND
XXX.XX - PROPOSED GROUND
IDALS
CAL883432B
NUTRIENT
REDUCTION
WETLAND
30402-C4-CROSS SECTION
DATE
REVISION SCHEDULE
DESCRIPTION BY
SHEET
TITLE
PROJECT
WITHOUT PRIOR WRITTEN CONSENT.
INC. AND MAY NOT BE USED, COPIED OR DUPLICATED
THIS DOCUMENT IS THE PROPERTY OF I & S GROUP,
PROJECT NO.
FILE NAME
DESIGNED BY
ORIGINAL ISSUE DATE
DRAWN BY
CLIENT PROJECT NO.
REVIEWED BY
D W
G L
O C
AT
IO
N
S:
\P
R O
JE
C
TS
\3
P R
O J\
0-
9\
ID
AL
S
C
AL
B-
C
AL
H O
U N
C O
U N
TY
IA
\3
P
R O
D U
C
TI
O N
F
IL
ES
\3
C
IV
IL
D \P
R O
D U
C
TI
O N
D W
G S\
2- C
4- C
R O
SS
S
EC
TI
O N
.D W
G S
AV
ED
B Y:
J
ES
SE
.C
R U
TC
H
ER
SHEET NOT VALID UNLESS THIS TEXT IS COLOR.
SCALE IN FEET
50 100
---- ---- C4-30
C4-30
2-13-2025
24-30402
CALHOUN COUNTY IOWA
CROSS SECTION
JAT
HPT
CDR
WES
T F
ORK C
AM
P C
REE
K
| Sheets and Views |
| C0-10 TITLE |
| C0-20 NOTES AND QUANTITIES |
| C0-30 DETAILS |
| C0-31 DETAILS |
| C0-32 DETAILS |
| C0-33 DETAILS |
| C1-10 SITE RESTORATION PLAN |
| C2-10 EXISTING SITE - SITE ACCESS |
| C3-10 SITE PLAN |
| C3-20 INLET PLAN & PROFILE |
| C3-21 OUTLET PLAN & PROFILE |
| C4-10 GRADING PLAN |
| C4-20 CUT - FILL |
| C4-30 CROSS SECTION |
File details come from the government source that posted it. Updated .