This is a set of architectural plans and construction drawings for a roof replacement project at the Goshen Fire Station located at 63 Goshen Road, Waterford, Connecticut 06385, prepared for the Town of Waterford. The project involves replacing approximately two-thirds of the facility's flat roofing system with a Ketone Ethylene Ester (KEE) roofing solution rated for high winds and storms in compliance with Connecticut Building Code standards. The scope of work includes removal of existing roofing and thermal insulation down to the structural steel deck, installation of new polyisocyanurate insulation with cover board and single-ply KEE membrane roofing, removal and reinstallation of gutters and downspouts, flashing of all roof penetrations including HVAC units and plumbing stacks, installation of new roof drains, removal of obsolete rooftop penetrations, and comprehensive site cleanup and debris removal. The drawings specify detailed construction assemblies, material specifications, flashing details for various roof conditions, and tapered insulation requirements for proper drainage. The bid submission deadline is September 10, 2024, at 1:00 pm, with an anticipated project completion timeline of 120 consecutive calendar days after the Notice to Proceed.
The project requires contractors to demonstrate specialized knowledge in KEE roofing installation and compliance with Connecticut prevailing wage laws, which mandate specific hourly rates for various construction worker classifications ranging from approximately $20.70 to $64.01 plus additional benefits. The contract includes a 25% set-aside requirement for small, minority, women, and disabled-owned businesses on the state-funded portion. Contractors must provide a 10% bid security if their total bid exceeds $50,000, comprehensive insurance and performance bonding, and a site-specific safety plan for review and approval prior to commencing work. The drawings emphasize strict adherence to OSHA compliance, fall protection requirements, debris control measures, and coordination with existing building operations, as the areas beneath the roof sections will remain occupied throughout construction. Retainage of 5% of the contract value will be held and released up to six months after successful project completion.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWN BY
CGS
APPROVED
M BOUDREAU
DATE
PR
O
JE
C
T:
G os he n R d.
A1.0
R oo f R ep la ce m en ts
Roof Plan
DRAWING NAME:
DRAWING NUMBER:
Pr oj ec t O w ne r:
LO
C
AT
IO
N
DRAWING STATUS:
A1.0
G os he n R d, W at er fo rd
, C T
DATE No. REVISIONS
Issued for Review:
26 OCT 2023
26 OCT 2023
G os he n
Fi re
D ep ar tm en t I nc
AutoCAD SHX Text
PV
AutoCAD SHX Text
PV
AutoCAD SHX Text
ROOF PLAN
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
APPROVED
M BOUDREAU
DATE
PR
O
JE
C
T:
G os he n R d
A1.1
R oo f R ep la ce m
Roof Work Plan
DRAWING NUMBER:
& General Notes
Pr oj ec t O w ne r:
LO
C
AT
IO
N
DRAWING STATUS:
A1.0
G os he n R d, W at er fo rd
, C T
DATE No. REVISIONS
Issued for Review:
26 OCT 2023
26 OCT 2023
G os he n
Fi re
D ep ar tm en t I nc
AutoCAD SHX Text
SITE LOCUS PLAN
AutoCAD SHX Text
- DECKING:
AutoCAD SHX Text
METAL DECK
AutoCAD SHX Text
- INSULATION:
AutoCAD SHX Text
- VAPOR BARRIER:
AutoCAD SHX Text N/A
AutoCAD SHX Text
CORE "A"
AutoCAD SHX Text
- ROOF:
AutoCAD SHX Text
TPO/PVC
AutoCAD SHX Text
EXISTING ROOF CONSTRUCTION
AutoCAD SHX Text
1 1/2" POLYISOCYANURATE INSULATION
AutoCAD SHX Text
- SUBSTRATE BOARD:
AutoCAD SHX Text
1/2" PERLITE
AutoCAD SHX Text
- COVER BOARD:
AutoCAD SHX Text
1/2" WOOD FIBER BOARD
AutoCAD SHX Text
NOTE #1
AutoCAD SHX Text ACCESS TO ALL ROOF AREAS SHALL BE VIA EXTENSION LADDER OR STAIR-TOWER, ERECTED & MAINTAINED BY THE ROOFING CONTRACTOR.
AutoCAD SHX Text ALL STAIR-TOWERS SHALL BE FENCED-OFF AND SECURED AGAINST UNAUTHORIZED ACCESS AT ALL TIMES. ALL EXTENSION LADDERS SHALL BE
AutoCAD SHX Text TAKEN-DOWN AT THE END OF EACH DAY AND SECURED TO PREVENT UNAUTHORIZED ACCESS, AS DIRECTED BY THE OWNER. ALL POTENTIAL
AutoCAD SHX Text LADDER AND/OR STAIR-TOWER STAGING AREAS ARE TO BE APPROVED BY THE OWNER, PRIOR-TO PROCEEDING. DO NOT RESTRICT ACCESS TO
AutoCAD SHX Text
BUILDING ENTRANCES, DOORS AND OTHER SIMILAR AREAS, AS DETERMINED BY THE OWNER.
AutoCAD SHX Text
NOTE #2
AutoCAD SHX Text ALL PROVIDED MEASUREMENTS, DRAWINGS, EQUIPMENT LOCATIONS, CORE-SAMPLE DATA AND OTHER SIMILAR INFORMATION IS PROVIDED AS A
AutoCAD SHX Text COURTESY TO BIDDERS. CERTAIN PIECES OF EQUIPMENT, PENETRATIONS AND/OR OTHER ITEMS MAY NOT BE FULLY/ACCURATELY-DEPICTED ON
AutoCAD SHX Text SUPPLIED DRAWINGS. EACH BIDDER IS REQUIRED TO THOROUGHLY-INSPECT THE PROJECT AND FIELD-VERIFY ALL EXISTING CONDITIONS. THE
AutoCAD SHX Text OWNER WILL NOT BE HELD RESPONSIBLE FOR A BIDDER'S FAILURE TO ADEQUATELY-ASSESS FIELD CONDITIONS, LOGISTICAL CHALLENGES OR
AutoCAD SHX Text OTHER VARIABLES WHICH AFFECT THE WORK. FIELD-VERIFY ALL DIMENSIONS, DETAILS & RELATED ITEMS, PRIOR TO BID-SUBMISSION.
AutoCAD SHX Text
NOTE #3
AutoCAD SHX Text THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND MAINTAINING PORTABLE SANITARY FACILITIES (ON THE ROOF SURFACE) FOR THEIR
AutoCAD SHX Text WORKFORCE THROUGHOUT THE COMPLETION OF THE WORK. SITE PORTABLE TOILETS IN LOCATIONS APPROVED BY THE OWNER.
AutoCAD SHX Text
NOTE #4
AutoCAD SHX Text ONCE ONSITE, THE ROOFING CONTRACTOR IS RESPONSIBLE FOR MAINTAINING ALL EXISTING ROOFING SYSTEMS IN A WATERTIGHT CONDITION. ALL
AutoCAD SHX Text BIDDERS ARE NOTIFIED THAT THE EXISTING ROOFING SYSTEMS ARE IN GENERALLY-POOR CONDITION AND HIGHLY-SUSCEPTIBLE TO DAMAGE. ANY
AutoCAD SHX Text LEAKAGE-RELATED PROBLEMS IN THE EXISTING ROOF SYSTEMS (REGARDLESS OF SOURCE) SHALL BE REPAIRED IN A TIMELY-FASHION AND
AutoCAD SHX Text
WITHOUT ADDITIONAL COST TO THE OWNER.
AutoCAD SHX Text
NOTE #5
AutoCAD SHX Text AREAS BENEATH THE ROOF SECTIONS IMPACTED BY THIS PROJECT WILL BE OCCUPIED THROUGHOUT CONSTRUCTION. ALL
AutoCAD SHX Text WORK IS TO BE CONDUCTED IN A SAFE, CONTROLLED AND ORDERLY-FASHION TO ENSURE THE SAFETY OF ALL BUILDING-OCCUPANTS/STAFF.
AutoCAD SHX Text TAKE ALL NECESSARY MEASURES TO MINIMIZE THE INCONVENIENCE TO BUILDING OCCUPANTS AND OPERATIONS.
AutoCAD SHX Text
NOTE #6
AutoCAD SHX Text THE UNSUPERVISED USE OF OPEN-FLAMES, TORCHES AND/OR SMOKING IS STRICTLY-FORBIDDEN THROUGHOUT THE COMPLETION OF THIS
AutoCAD SHX Text PROJECT. IF CUTTING-TORCHES OR SPARK-PRODUCING SAWS ARE REQUIRED, THE CONTRACTOR MUST NOTIFY THE OWNER (WELL IN-ADVANCE)
AutoCAD SHX Text TO OBTAIN THE NECESSARY PERMITS/APPROVALS FOR SUCH WORK. IF WORKERS ARE FOUND TO BE VIOLATING ANY ASPECT OF THIS POLICY, AutoCAD SHX Text THE OWNER WILL ENLIST THE FULL-TIME SERVICES OF THE LOCAL FIRE-DEPARTMENT TO PROVIDE FIRE-PROTECTION. ANY/ALL EXPENSES
AutoCAD SHX Text
FOR THESE SERVICES WILL BE CHARGED TO THE CONTRACTOR.
AutoCAD SHX Text
NOTE #7
AutoCAD SHX Text WHENEVER OBSOLETE ROOFTOP PENETRATIONS OR OTHER SIMILAR ITEMS ARE TARGETED FOR REMOVAL FROM THE ROOF SYSTEM, THE
AutoCAD SHX Text CONTRACTOR IS RESPONSIBLE FOR PROVIDING INTERIOR PROTECTION TO PROPERTY AND BUILDING-OCCUPANTS. COORDINATE ALL SUCH ACTIVITIES
AutoCAD SHX Text AT LEAST 48 HOURS IN-ADVANCE, WITH THE OWNER, SO THAT APPROPRIATE ACCESS/CLEARANCE AND STAFF CAN BE DEDICATED.
AutoCAD SHX Text
NOTE #8
AutoCAD SHX Text THE CONTRACTOR MUST CONTROL THEIR ACTIVITIES AT ALL TIMES. THE OWNER IS PARTICULARLY-CONCERNED ABOUT THE POSSIBILITY OF
AutoCAD SHX Text HIGH-WINDS DELIVERING DEBRIS, MATERIALS AND OTHER JOB-RELATED DEBRIS TO THE SIDEWALKS/STREETS AND OTHER ADJACENT CAMPUS BUILDINGS.
AutoCAD SHX Text TO MIGRATE FROM THE SITE. THE OWNER, AT ANY TIME, RESERVES THE RIGHT TO TERMINATE THE CONTRACTOR'S ACTIVITIES IF JOBSITE
AutoCAD SHX Text DEBRIS/MATERIAL IS IMPROPERLY-SECURED. PRIOR TO COMMENCING THE WORK, THE OWNER WILL REQUIRE THE SUCCESSFUL CONTRACTOR TO
AutoCAD SHX Text PROVIDE A DETAILED DESCRIPTION OF ALL STEPS/MEASURES BEING TAKEN TO CONTROL THE JOBSITE THROUGHOUT CONSTRUCTION ACTIVITIES.
AutoCAD SHX Text ERECT DEBRIS FENCING AND TAKE ALL OTHER NECESSARY STEPS TO ENSURE THAT PROJECT-RELATED DEBRIS/MATERIALS ARE NOT ALLOWED
AutoCAD SHX Text
NOTE #9
AutoCAD SHX Text CONTRACTOR IS REQUIRED TO EXECUTE ALL WORK IN STRICT ACCORDANCE WITH STATE, FEDERAL AND OWNER'S SAFETY REGULATIONS.
AutoCAD SHX Text OSHA COMPLIANCE IS MANDATORY THROUGHOUT ALL ASPECTS OF THE PROJECT. USE OF FALL-PROTECTION DAVITS, PERIMETER WARNING
AutoCAD SHX Text LINES AND ANY OTHER CONTROLS NEEDED TO PROTECT THE SAFETY OF WORKERS, BUILDING-OCCUPANTS AND GROUND-BASED PERSONNEL
AutoCAD SHX Text IS THE SOLE AND COMPLETE RESPONSIBILITY OF THE ROOFING CONTRACTOR. THE SUCCESSFUL CONTRACTOR WILL BE REQUIRED TO PROVIDE
AutoCAD SHX Text THE OWNER'S SAFETY OFFICER WITH A SITE-SPECIFIC SAFETY-PLAN FOR REVIEW/APPROVAL, PRIOR TO COMMENCING ANY WORK.
AutoCAD SHX Text
NOTE #10
AutoCAD SHX Text ALL PROJECT-RELATED DEBRIS, AS WELL AS NEW MATERIALS/SUPPLIES, ARE TO BE DELIVERERD TO/FROM THE ROOF SURFACES VIA CRANE/HOISTS
AutoCAD SHX Text DURING DESIGNATED HOURS. HOURS OF CRANE/HOIST ACTIVITY WILL BE DESIGNATED IN ADVANCE BY THE OWNER ALL CRANE SERVICE TO THE
AutoCAD SHX Text ROOF AREAS WILL TAKE-PLACE FROM THE PRE-DESIGNATED STAGING AREA AS INDICATED. THE PERIMETER OF THE GROUND-BASED
AutoCAD SHX Text STAGING-AREA IS TO BE CORDONED-OFF WITH FLAGS/CONES/BARRICADES (BY THE ROOFING CONTRACTOR) TO HELP PREVENT UNAUTHORIZED
AutoCAD SHX Text ACCESS. ROOFING CONTRACTOR WILL IMMEDIATELY CEASE CRANE/HOISTING OPERATIONS IF UNAUTHORIZED, GROUND-BASED PERSONNEL ARE IN THE
AutoCAD SHX Text VICINITY OF THE CONTRACTOR'S STAGING-AREA. IMMEDIATELY-NOTIFY THE OWNER FOR ASSISTANCE IF ACCESS-CONTROL ISSUES ARISE.
AutoCAD SHX Text
NOTE #11
AutoCAD SHX Text DIRECTION. THE SUCCESSFUL ROOFING CONTRACTOR IS EXPECTED TO CONTRACT WITH A TAPERED INSULATION MANUFACTURER TO PROVIDE A FIELD
AutoCAD SHX Text TAPERED INSULATION WILL BE REQUIRED FOR PROPER DRAINAGE IN LOCATIONS AS DESIGNATED. A PLAN HAS BEEN PROVIDED TO PROVIDE DESIGN
AutoCAD SHX Text VERIFED LAYOUT AND DESIGN THROUGH A SHOP DRAWING REVIEW AND APPROVAL PROCESS TO ENSURE THAT PROPER DRAINAGE IS BEING PROVIDED.
AutoCAD SHX Text
GENERAL CONSTRUCTION NOTES:
AutoCAD SHX Text
PV
AutoCAD SHX Text
PV
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
FLASH EXIST CURBS PER 5/A2.1 (TYP)
AutoCAD SHX Text
SEE 4/A2.1 FOR PLUMBING STACK DETAIL (TYP)
AutoCAD SHX Text
SEE 4/A2.1 FOR PLUMBING STACK DETAIL (TYP)
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text A2.1
AutoCAD SHX Text
AutoCAD SHX Text
ROOF WORK PLAN
AutoCAD SHX Text
NTS
AutoCAD SHX Text D1.1
AutoCAD SHX Text
DEMOLITION GENERAL WORK NOTES::
AutoCAD SHX Text
XXX
AutoCAD SHX Text
NOTES WITHOUT ARROW INDICATE ENTIRE SPACE/AREA
AutoCAD SHX Text
XXX
AutoCAD SHX Text
NOTES WITH ARROWS INDICATE SPECIFIC AREAS &/OR ITEMS
AutoCAD SHX Text D1
AutoCAD SHX Text
ROOFING/FLASHING
AutoCAD SHX Text D1.2
AutoCAD SHX Text R&D EXISTING FASCIA AND RELATED FLASHING. REFER TO DETAIL 2&3/A2.1 FOR NEW PERIMETER FASCIA DETAILS. SEE BID FORM UNIT COST FOR DAMAGED WOOD BLOCKING REMOVAL & REPLACEMENT
AutoCAD SHX Text R&D EXISTING ADHERED PVC/TPO ROOFING SYSTEM INCLUDING ALL RELATED FLASHING DOWN TO STRUCTURAL DECK TO REMAIN. SEE DRAWING A1.0 FOR EXISTING ROOF CONSTRUCTION CORE INFORMATION
AutoCAD SHX Text D15
AutoCAD SHX Text
PLUMBING AND HVAC PENETRATIONS
AutoCAD SHX Text D15.2
AutoCAD SHX Text ALL ROOF MOUNTED HVAC UNITS & CONDENSER UNITS ARE TO BE DISCONNECTED, AND RE-CONNECTED BY THE OWNER'S DESIGNATED CONTRACTOR. ROOFER SHALL PROVIDE ALL ASSOCIATED HOISTING AND MODIFICATIONS REQUIRED TO PROVIDE 8" MIN. CLEARANCE TO NEW ROOF SURFACE- NEW PITCH POCKETS TO BE F&I BY THE ROOFING CONTRACTOR - REFER TO DETAILS 9/A2.1 FOR PITCH POCKET / WORK BOX DETAILS
AutoCAD SHX Text D15.3
AutoCAD SHX Text D15.1
AutoCAD SHX Text EXISTING CURB MOUNTED HVAC UNITS / FAN UNIT / DUCT PENETRATIONS TO REMAIN. - ROOFER SHALL PROVIDE ALL ASSOCIATED HOISTING AND MODIFICATIONS REQUIRED TO PROVIDE 8" MIN. CLEARANCE TO NEW ROOF SURFACE- REFER TO DETAIL 5/A2.1 FOR CURB FLASHING DETAIL. DISCONNECT AND RE-CONNECT BY OWNER'S DESIGNATED CONTRACTOR
AutoCAD SHX Text EXISTING VENT STACKS TO REMAIN UNLESS NOTED OTHERWISE - ALL VENT PIPE FLASHING F&I BY THE ROOFING CONTRACTOR - REFER TO DRAWING 4/A2.1 FOR VENT FLASHING DETAIL
AutoCAD SHX Text D15.4
AutoCAD SHX Text ALL ROOF DRAINS ARE TO BE REMOVED AND REPLACED WITH NEW CAST IRON ROOF DRAIN ASSEMBLY, INCLUDING TOP SET DECK PLATE AND ADJUSTABLE DECK CLAMP AND CAST IRON STRAINER - TO TIE INTO EXISTING ROOF DRAIN PIPING BY THE ROOFING CONTRACTOR - REFER TO DRAWING 8/A2.1 FOR ROOF DRAIN DETAIL
AutoCAD SHX Text D1.3
AutoCAD SHX Text R&D EXISTING GUTTER, DOWNSPOUTS AND RELATED PERIMETER METAL SYSTEM IN ITS ENTIRETY INCLUDING ANCHOR CLIPS AND ALL RELATED FASTENERS - REFER TO DETAIL 2/A2.1 FOR NEW GUTTER DETAILS
AutoCAD SHX Text D16.1
AutoCAD SHX Text D16
AutoCAD SHX Text UNLESS NOTED OTHERWISE ALL EXISTING ROOF MOUNTED ELECTRICAL AND COMMUNICATIONS CONDUIT AND RELATED WORK BOXES, CONTROL PANELS, SECURITY CAMERAS, ETC. IS TO BE REMOVED AND/OR RE-WORKED TO ALLOW FOR INSTALLATION OF NEW ROOFING AND FLASHING SYSTEMS BY THE OWNER'S DESIGNATED ELECTRICAL CONTRACTOR. THE ROOFING CONTRACTOR SHALL CAREFULLY COORDINATE AND FACILITATE WORK BETWEEN THE TWO TRADES.
AutoCAD SHX Text
ELECTRICAL AND COMMUNICATIONS SYSTEMS
AutoCAD SHX Text
ROOF IMAGES
AutoCAD SHX Text
CORE IMAGES
AutoCAD SHX Text D1.3
AutoCAD SHX Text D1.3
AutoCAD SHX Text D1.3
AutoCAD SHX Text D1.3
AutoCAD SHX Text D1.3
AutoCAD SHX Text D1.3
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text
ROOF 1
AutoCAD SHX Text
ROOF 2
AutoCAD SHX Text
ROOF 3
AutoCAD SHX Text
ROOF 4
AutoCAD SHX Text
ROOF N.I.S.
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.2
AutoCAD SHX Text D1.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.2
AutoCAD SHX Text D15.3
AutoCAD SHX Text D1.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.2
AutoCAD SHX Text D15.3
AutoCAD SHX Text D1.1
AutoCAD SHX Text D15.1
AutoCAD SHX Text D15.2
AutoCAD SHX Text D15.3
AutoCAD SHX Text D1.1
AutoCAD SHX Text D15.4
AutoCAD SHX Text D15.4
AutoCAD SHX Text D15.4
AutoCAD SHX Text D15.4
AutoCAD SHX Text D15.4
D15.4
APPROVED
M BOUDREAU
DATE
PR
O
JE
C
T:
G os he n R d
A1.2
R oo f R ep la ce m
Roof Images
DRAWING NUMBER:
Pr oj ec t O w ne r:
LO
C
AT
IO
N
DRAWING STATUS:
G os he n R d, W at er fo rd
, C T
DATE No. REVISIONS
Issued for Review:
26 OCT 2023
26 OCT 2023
G os he n
Fi re
D ep ar tm en t I nc
ROOF IMAGES
APPROVED
M BOUDREAU
DATE
PR
O
JE
C
T:
G os he n R d
A2.1
R oo f R ep la ce m
Roof Details
DRAWING NUMBER:
Pr oj ec t O w ne r:
LO
C
AT
IO
N
DRAWING STATUS:
G os he n R d, W at er fo rd
, C T
DATE No. REVISIONS
Issued for Review:
26 OCT 2023
26 OCT 2023
G os he n
Fi re
D ep ar tm en t I nc
AutoCAD SHX Text REMOVE ALL EXISTING ROOFING AND THERMAL INSULATION TO EXISTING STEEL STRUCTURAL DECK TO REMAIN - SEE SPECS FOR ADDITIONAL REQUIREMENTS (TYP)
AutoCAD SHX Text
ROOF TYPE "A" - STEEL DECK
AutoCAD SHX Text
VAR.
AutoCAD SHX Text
VAR.
AutoCAD SHX Text LTTR-30 (MIN.) 5.2" FLAT STOCK POLYISOCYANURATE INSULATION ADHERED WITH LOW RISE FOAM ADHESIVE PER SPECS. (TYP)PER SPECS. (TYP) (TYP)
AutoCAD SHX Text 1/2" DENSDECK PRIME GYPSUM-FIBER ROOF BOARD ADHERED WITH TREMCO LOW RISE FOAM INSULATION ADHESIVE INSULATION ADHESIVE - 3/4" RIBBONS @ 6" O.C. PER SPECS. (TYP) (TYP)
AutoCAD SHX Text 1 PLYS OF TREMPLY KEE FB (60 MIL) - - ADHERED TO COVERBOARD WITH POWERPLY BIO ADHESIVE TF PER SPECS. (TYP)PER SPECS. (TYP)
AutoCAD SHX Text
HEAT WELD ALL SEAMS IN KEE SHEET PER SPECIFICATIONS (TYP)
AutoCAD SHX Text
NEMO ASSEMBLY S-169 UL 37
AutoCAD SHX Text
VAPOR RETARDER SEE SPECS FOR ADDITIONAL REQUIREMENTS (TYP)
AutoCAD SHX Text
12" DENSDECK PRIME SUBSTRATE BOARD FASTENED TO DECK
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
COUNTER-FLASHING @ MASONRY WALLS
AutoCAD SHX Text TREMPLY KEE REINFORCED MEMBRANE FLASHING - ADHERE TO SUBSTRATE WITH APPROVED ADHESIVE - HEAT WELD ALL LAPS(TYP)
AutoCAD SHX Text PRESSURE BAR FASTENED @ 8"0.C. - SET TOP OF KEE FLASHING IN TF TAPE AND KEE APPROVED SEALANT PER SPEC (TYP)
AutoCAD SHX Text
SURFACE MOUNTED REGLET WITH APPROVED SEALANT APPLIED AT TOP OF REGLET
AutoCAD SHX Text
CONT. SEALANT BEAD
AutoCAD SHX Text
TREMPLY KEE 6" STRIP IN FLASHING SHEET INSTALLED OVER NEW KEE COATED DRIP EDGE.
AutoCAD SHX Text INSTALL CONTINUOUS WATERPROOF MEMBRANE FROM FIELD OF ROOF OVER NEW P.T. BLOCKING TO LAP EXISTING WALL CONSTRUCTION 6" MIN. (TYP)
AutoCAD SHX Text NEW 5"X5" PREFINISHED 22 GA. GALVANIZED STEEL GUTTER WITH GUTTER BRACKETS AT 12" O.C. MAX (TYP)
AutoCAD SHX Text
1) PROVIDE 4'x6' WIDE CORR. BOX-DOWNSPOUTS.
AutoCAD SHX Text
SLOPE ALL GUTTERS 1/8":12" MIN. FOR PROPER
AutoCAD SHX Text
AND SPLASHBLOCKS.
AutoCAD SHX Text
DRAINAGE. PROVIDE ALL NECESSARY BRACKETS
AutoCAD SHX Text
EXISTING EXTERIOR WALL TO REMAIN - VERIFY CONDITIONS IN FIELD (TYP)
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text NEW PRE-FINISHED KEE COATED DRIP EDGE & CONT. 22 GA. CLEAT INSTALLED OVER GUTTER FLANGE - PRIME & SET DRIP EDGE FLANGE IN MASTIC AND FASTEN @ 4" O.C. - PRIME TOP FLANGE BEFORE STRIPPING
AutoCAD SHX Text
TYPICAL GUTTER FLASHING DETAIL
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
TYPICAL FASCIA DETAIL
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text INSTALL NEW 2x6 P.T. WOOD BLOCKING TO HEIGHT OF INSULATION AND COVER BOARD - SECURE TO DECK (TYP)
AutoCAD SHX Text
MECHANICALLY ATTACH SINGLE PLY MEMBRANE AT 4" O.C.
AutoCAD SHX Text
HEAT WELD ALL LAPS
AutoCAD SHX Text
CONTINUOUS CLEAT (GAUGE THICKER THAN FASCIA METAL, FASTEN 16" O.C.)
AutoCAD SHX Text
COATED METAL DRIP EDGE WITH HEMMED EDGE
AutoCAD SHX Text
KEE APPROVED SEALANT
AutoCAD SHX Text
STAINLESS STEEL CLAMP
AutoCAD SHX Text
KEE ONE PIECE BOOT
AutoCAD SHX Text
HEAT WELDED LAP
AutoCAD SHX Text
VENT STACK
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
KEE FLEECE BACKED MEMBRANE
AutoCAD SHX Text
FULLY ADHERED TO SUBSTRATE W/
AutoCAD SHX Text
PEBA ADHESIVE PER SPEC.
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
PREFORMED PIPE FLASHING
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
CURB FLASHING DETAIL
AutoCAD SHX Text TREMPLY KEE REINFORCED MEMBRANE FLASHING - ADHERE TO SUBSTRATE WITH APPROVED ADHESIVE - HEAT WELD ALL LAPS(TYP)
AutoCAD SHX Text
MANUFACTURER APPROVED FASTENERS @ 4" O.C. STAGGERED
AutoCAD SHX Text KEE NON-FLEECE BACKED FLASHING MEMBRANE FULLY ADHERED TO SUBSTRATE WITH PEBA ADHESIVE PER SPEC.
AutoCAD SHX Text
POWERPLY ENDURE BIO ADHESIVE
AutoCAD SHX Text
METAL COUNTERFLASHING (FABRICATED BY ROOFER)
AutoCAD SHX Text
TF TAPE & TERMINATION BAR FASTENED 8" O.C.
AutoCAD SHX Text
NEW P.T. WOOD BLOCKING TO RAISE CURB 8" MIN ABOVE NEW FINISHED ROOF (TYP)
AutoCAD SHX Text LIFT EXISTING CURB-MOUNTED EQUIPMENT AND RE-SECURE WITH STAINLESS-STEEL BOLTS & NEOPRENE WASHERS @ 8" 0.C. (TYPICAL)
AutoCAD SHX Text
HEAT WELDED LAP
AutoCAD SHX Text EXISTING MASONRY PARAPET CONSTRUCTION TO REMAIN - INSTALL CONT. B.R. & SEALANT @ NEW COPING JOINT (TYP)
AutoCAD SHX Text NEW P.T. BLOCKING ANCHORED CAREFULLY TO EXIST. TERRA COTTA CAP TO REMAIN - PROVIDE CONT. 1/4" MIN. PITCH TO DRAIN (TYP)
AutoCAD SHX Text NOTE: FASCIA OF PARAPET CAP MUST : FASCIA OF PARAPET CAP MUST COMPLETELY COVER EXISTING CONCRETE COPING - VERIFY DIMENSION IN FIELD (TYP)
AutoCAD SHX Text
KEE FLEECE BACKED MEMBRANE
AutoCAD SHX Text
FULLY ADHERED TO SUBSTRATE
AutoCAD SHX Text
WITH PEBA PER SPEC.
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
PARAPET COPING DETAIL
AutoCAD SHX Text W/ STANDING-SEAM CONNECTIONS. SECURE ONE (1) SIDE WITH STAINLESS-STEEL SCREWS & NEOPRENE WASHERS (8" O.C.). SECURE OPP. SIDE WITH WITH 50 MIL CONTINUOUS ALUM. CLEAT (TYPICAL)
AutoCAD SHX Text 1/2" CDX PLYWOOD FASTENED TO INSIDE FACE OF PARAPET WALL CONSTRUCTION TO REMAIN PER SPECIFICATIONS (TYP)
AutoCAD SHX Text
POWERPLY ENDURE BIO ADHESIVE
AutoCAD SHX Text
KEE NON-FLEECE BACKED MEMBRANE FULLY ADHERED TO SUBSTRATE WITH PEBA PER SPEC.
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
WALL COUNTERFLASHING DETAIL
AutoCAD SHX Text SECURE INTO SUBSTRATE WITH S.S. SCREWS @ 8" 0.C. - LAP AIR/VAPOR BARRIER OVER TOP OF COUNTERFLASHING 4" MIN. (TYP.)
AutoCAD SHX Text
NEW 16 OZ. COPPER COUNTERFLASHING - RUN UP 4" MIN. BEHIND RAINSCREEN SIDING
AutoCAD SHX Text
TF TAPE & KEE APPROVED SEALANT
AutoCAD SHX Text
PRESSURE BAR FASTENED @ 8"O.C.
AutoCAD SHX Text
POWERPLY ENDURE BIO ADHESIVE
AutoCAD SHX Text
KEE NON-FLEECE BACKED MEMBRANE FULLY ADHERED TO SUBSTRATE WITH PEBA PER SPEC.
AutoCAD SHX Text
HEAT WELDED LAP
AutoCAD SHX Text
KEE FLEECE BACKED MEMBRANE FULLY ADHERED TO SUBSTRATE WITH PEBA PER SPEC.
AutoCAD SHX Text
REFER TO NEW ROOF ASSEMBLY DETAILS FOR NEW ROOF SYSTEM CONSTRUCTION (TYP)
AutoCAD SHX Text
MEMBRANE MUST EXTEND MINIMUM 1" BEYOND THE BOLT HOLES.
AutoCAD SHX Text
FIELD WELD MUST NOT PASS UNDER THE CLAMPING RING.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
ROOF DRAIN DETAIL
AutoCAD SHX Text INFILL EXISTING OPENING BETWEEN NEW DRAIN BODY AND DECK OPENING WITH SPRAY FOAM INSULATION (TYP)
AutoCAD SHX Text
TOP MOUNT DECK CLAMP WITH ADJUSTABLE BODY SECURE TO STRUCTURAL DECK (VIF)
AutoCAD SHX Text
TAPERED PRE-FAB SUMP AT ROOF DRAIN - R-25 (4.2") MIN. AT DRAIN (TYP)
AutoCAD SHX Text
HEAT WELDED LAP
AutoCAD SHX Text
KEE FLEECE BACKED MEMBRANE FULLY ADHERED TO SUBSTRATE WITH PEBA PER SPEC.
AutoCAD SHX Text
KEE FLASHING MEMBRANE
AutoCAD SHX Text
DRAIN CLAMP RING
AutoCAD SHX Text
TOP MOUNT C.I. ROOF DRAIN W/ ADJUST. HEIGHT SUMP
AutoCAD SHX Text
THE CLAMPING RING BOLT MUST PENETRATE THE MEMBRANE.
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
USE KEE COATED METAL TO FORM PITCH PAN.
AutoCAD SHX Text
ALLOW 2" MINIMUM CLEARANCE AROUND THE PROJECTION.
AutoCAD SHX Text
KEE PREFABRICATED CORNERS MUST BE USED AT ALL 4 CORNERS
AutoCAD SHX Text
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text A2.1
AutoCAD SHX Text
PITCH POCKET FLASHING DETAIL
AutoCAD SHX Text 1"
AutoCAD SHX Text
NEW P.T. BLOCKING TO MATCH HEIGHT OF NEW INSULATION & COVERBOARD (TYP)
AutoCAD SHX Text
KEE MEMBR. HEAT WELDED
AutoCAD SHX Text
4" FLANGE WITH HEMMED EDGE FASTENED 4" O.C.
AutoCAD SHX Text
HEAT WELDED LAP
AutoCAD SHX Text
KEE COATED METAL
AutoCAD SHX Text
NON-SHRINK GROUT
AutoCAD SHX Text
PITCH PAN SEALANT
AutoCAD SHX Text
OPTIONAL METAL HOOD
DO NOT CUT PREFABRICATED BOOT. IT MUST BE PULLED OVER VENT PIPE. PREFABRICATED BOOTS ARE AVAILABLE IN SMALL & LARGE SIZES, AND MUST BE USED WHENEVER POSSIBLE TO FLASH PIPES 1" TO 8" IN DIAMETER.