Plans 4 of 4 18412.pdf
PDF 674 KB Posted
- Attached to
- 472/18412; Brooks CF - Pole Building
- Solicitation number
- RFQ 171 200000000001 1
- Issued by
- Mackinac County, Michigan
About this file
This is a construction plan document for the State of Michigan Department of Technology, Management and Budget, specifically for a new storage facility project at E.C. Brooks Correctional Facility in Muskegon, Michigan. The project involves the construction of a 40-foot by 60-foot metal-sided storage building with a 16-foot nominal high sidewalls, asphalt shingle roof, and concrete floor slab. The facility will include two 3-foot by 7-foot insulated hollow metal building access doors and three insulated overhead service doors of varying sizes (10 feet by 10 feet and 10 feet by 14 feet). The general contractor bears responsibility for all coordination of trades, permitting, site preparation, and meeting applicable Michigan Building Code 2015 requirements, including design loads for wind (82 miles per hour nominal design wind speed), snow (40.3 pounds per square foot), and other structural requirements. The project specifications include engineered trusses, concrete floor slab with welded wire fabric reinforcement on a compacted sand-gravel subbase, traditional pole building construction with pressure-treated wood posts rated AWPA UC4B, and a complete metal gutter and downspout drainage system. The bidding date was October 1, 2019, with plan review completed September 19, 2019.
The project includes three deduct alternates: replacement of the concrete apron at overhead doors with dolomite or gravel, omission of gutters and downspouts with associated drainage components, and substitution of uninsulated doors for the specified insulated overhead doors. Special inspections are required for wood truss fabricator's shop compliance and soil bearing capacity verification. Foundation design is based on a soils investigation report dated August 27, 2019, requiring minimum allowable bearing pressure of 2,500 pounds per square foot for shallow circular drilled concrete piers. All concrete work must comply with American Concrete Institute standards with specified compressive strengths ranging from 3,000 to 4,000 pounds per square inch depending on application. The contractor must obtain all necessary state and local permits and comply with local ordinances regarding working hours, noise levels, and dust control, and must contact Miss Dig at least 72 hours prior to excavation to locate underground utilities. Contract number is 00815, filed under Contract No. 472-18412-GAG.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Plans 2 of 4 18412.pdf | ||
| Plans 1 of 4 18412.pdf | ||
| Advertisement 18412.pdf | ||
| Specifications 18412 (s).pdf | ||
| LEIN Request 18412.pdf | ||
| Plans 3 of 4 18412.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL BUILDING INFORMATION:
· NEW 40' X 60' STORAGE BUILDING (NOT INSULATED)
· METAL SIDING WALL PANELS
· 16' (NOMINAL) HIGH SIDEWALLS
· ASPHALT SHINGLE ROOF
· (2) 3' X 7' INSULATED HOLLOW METAL BUILDING ACCESS DOORS
· (3) INSULATED OVERHEAD SERVICE DOORS
· ALL FLASHINGS AND TRIM
· NOTE: SEE SHEET A1 FOR PROJECT ALTERNATES
CONTRACTOR REQUIREMENTS AND RESPONSIBILITIES:
· GENERAL CONTRACTOR (OR BUILDER) IS RESPONSIBLE FOR ARRANGING
CONSTRUCTION AND THE COORDINATION OF ALL OTHER INVOLVED TRADES AND
PRE-CONSTRUCTION ACTIVITIES INCLUDING:
·· PERMITTING
·· MEETING ALL APPLICABLE BUILDING CODE REQUIREMENTS (I.E. DESIGN LOADS
FOR WIND, SNOW, DEFLECTION, DRIFT, UPLIFT, AND SOIL BEARING) SET BY THE
STATE AND LOCAL BUILDING OFFICIALS, FIRE DEPARTMENT, AND ANY OTHER AHJ
(AUTHORITY HAVING JURISDICTION)
·· ENGINEERED TRUSSES
·· ENGINEERED FRAMED OPENINGS, BRACING, AND OTHER STRUCTURAL ELEMENTS,
BUILDING COMPONENTS, OR FEATURES
·· ENGINEERED CONCRETE FLOOR SLAB AND COLUMN FOOTINGS
·· SITE PREPARATION AND FINISHING
SITE REQUIREMENTS:
· PROVIDE EXCAVATION, SAND-GRAVEL SUB-BASE (MDOT21AA), AND LEVELING FOR
BUILDING CONSTRUCTION (SOIL BEARING TESTING WILL BE ARRANGED AND PROVIDED
BY THE OWNER)
· PROVIDE FINAL GRADING AROUND BUILDING PERIMETER OVERHEAD DOOR ENTRY
APRON TO ALLOW FOR POSITIVE DRAINAGE AWAY FROM BUILDING
· TIE-IN NEW GRADES TO EXISTING GRADES AND SITE DRIVE/PARKING AREA
· COORDINATE GUTTER AND DOWNSPOUT DRAINAGE LOCATIONS AS SHOWN; SEE
DRAWINGS
· COORDINATE SURFACE DRAINAGE WITH REVISED GRADING SHOWN BETWEEN NEW AND
EXISTING STRUCTURES
BUILDING STRUCTURE:
· TRADITIONAL POLE BULDING CONSTRUCTION
(NOTE: ALL WOOD FRAMING IS REQUIRED TO BE AWPA UC3B OR BETTER)
·· 6" x 6" TREATED WOOD POSTS (RATED AWPA UC4B) @ 8' O.C. (MAX, TYP); SEE
FLOOR PLAN FOR SPACING AT DOOR OPENINGS; FINAL SPACING AND POST SIZES
TO MEET LOCAL BUILDING CODE REQUIREMENTS
·· 8" TREATED SKIRT BOARDS (RATED AWPA UC4B) AROUND BUILDING PERIMETER
·· 2" x 6" WALL GIRTS AT 24" O.C. (OR STEEL EQUIVALENT)
·· TRUSSES AND TRUSS GIRDERS PER ENGINEERING REQUIREMENTS DETERMINED
BY BUILDING SUPPLIER/MANUFACTURER
BUILDING CONSTRUCTION:
· WALLS:
·· MANUFACTURER'S STANDARD HEIGHT BASED ON INDICATED NOMINAL HEIGHT ON
DRAWINGS
·· PANEL MANUFACTURER STANDARD GAUGE ZINC COATED (GALVANIZED) OR
ALUMINUM-ZINC ALLOY-COATED STEEL PANELS FASTENED WITH EXPOSED
FASTENERS (PANEL MANUFACTURER RECOMMENDED SCREWS WITH NEOPRENE
WASHERS)
·· FACTORY FINISH BOTH SIDES OF WALL PANELS (INSULATION AND/OR INTERIOR
LINER PANELS ARE NOT REQUIRED)
· CONCRETE FLOOR SLAB AND OVERHEAD DOOR ENTRY APRON:
·· 6" 4000 PSI CONCRETE SLAB REINFORCED W/ WELDED WIRE FABRIC (4"x4" -
W4.0XW4.0)
·· 6 BAG MIN. CEMENT CONTENT W/ 5% MIN. AIR-ENTRAINMENT; 4" SLUMP MAX.
·· PROVIDE COMPACTED SAND-GRAVEL SUB-BASE (MDOT21AA) UNDER BUILDING
AREA AND COORDINATE DEPTH OF BASE WITH FLOOR SLAB ELEVATION AND
SLOPE SHOWN ON DRAWINGS; ADJUST EXISTING GRADES TO MEET ANTICIPATED
FINAL SITE GRADING
·· PROVIDE SAWCUT JOINTS IN FLOOR SLAB @ 12' O.C. MAX
·· PROVIDE CONTINUOUS 6' WIDE CONCRETE APRON AT OVERHEAD DOOR
OPENINGS; SEE PLAN
·· PROVIDE SLIP-RESISTANT (BROOM) FINISH AT EXTERIOR LOCATIONS SUBJECT TO
FOOT TRAFFIC
· ROOF:
·· 30-YEAR WARRANTY ASPHALT SHINGLES; COLOR TO BE SELECTED FROM
COMPLETE RANGE OF MANUFACTURER STANDARD AVAILABLE COLORS
·· 15# CONTINUOUS ROOF FELT AND 3' OF CONTINUOUS ICE & WATER SHIELD
ALONG EAVES WITH GUTTERS
·· 1/2" OSB ROOF SHEATHING WITH CLIPS ON ENGINEERED TRUSSES (@ 24" OR AS
REQUIRED)
·· PROVIDE 6" SEAMLESS METAL GUTTER AND DOWNSPOUT DRAINAGE SYSTEM
ALONG FULL LENGTH OF EAVES (BOTH SIDES); ROUTE DOWNSPOUTS TO SPLASH
BLOCKS AS SHOWN
·· PROVIDE MATCHING PRE-FINISHED METAL DRIP EDGE AT EAVES AND GABLE ENDS
·· ONE FOOT OVERHANG ALL SIDES
·· PROVIDE PRE-FINISHED ALUMINUM VENTED SOFFITS AND CONTINUOUS RIDGE
VENT; SHINGLE OVER RIDGE VENT
· FINISHES:
·· ALL FLASHING AND TRIM: FACTORY FINISHED
·· WALL PANELS: TWO-COAT FLUOROPOLYMER FACTORY APPLIED FINISH ON EACH
FACE OF PANELS SELECTED FROM MANUFACTURER'S SELECTION OF STANDARD
COLORS
·· ALL OTHER BUILDING FINISHES: PRE-FINISHED WHERE AVAILABLE AND TO BE
DETERMINED BY OWNER FOLLOWING WALL PANEL COLOR SELECTION
DOORS AND OPENINGS:
· 3'-0" X 7'-0" DOORS:
·· QUANTITY: 2
·· INCLUDE 5' x 5' EXTERIOR CONCRETE PAD AT EACH OPENING
·· INSULATED HOLLOW METAL (GALVANIZED, HEAVY DUTY COMMERCIAL GRADE,
FACTORY APPLIED FINISH)
·· FACTORY WELDED STEEL DOOR FRAMES W/ MITERED CORNERS
·· PROVIDE WEATHER STRIPPING AND ADA/ MICHIGAN BARRIER FREE ALUM.
THRESHOLD
·· BACKSET DOORS AND LOCKS 2 34"
·· SECURITY: SCHLAGE D53RD626ORB LOCKSET WITH CONSTRUCTION CORES; FINAL
FINISHED CORES AND KEYING BY OWNER
· UPWARD-ACTING SECTIONAL OVERHEAD SERVICE DOORS (SIZES AND ARRANGEMENT
ON DRAWINGS):
·· QUANTITY: 3
·· HEAVY DUTY COMMERCIAL GRADE GALVANIZED
·· INCLUDE POLYURETHANE INSULATION BONDED TO FACING SHEETS OF
GALVANIZED SHEET STEEL SECTIONS
·· FACTORY APPLIED FINISH IN COLOR SELECTED FROM MANUFACTURER'S
STANDARD AVAILABLE COLORS
·· PROVIDE WEATHER STRIPPING AND TORSION SPRING LIFT, CROSS HEAD SHAFT,
AND BRAIDED STEEL CABLES FOR MANUAL OPERATION
·· SECURITY: INCLUDE SECURITY MECHANISM LOCKABLE FROM THE INTERIOR
STRUCTURAL LOADS
1. BUILDING CODE - MICHIGAN BUILDING CODE 2015.
2. STRUCTURAL DESIGN CODES AND STANDARDS:
DESIGN LOADS - ASCE 7-10
CONCRETE - ACI 318-14
WOOD - ANSI/AWC NDS-15
3. DESIGN LIVE LOADS:
BUILDING RISK CATEGORY: I
SNOW:
GROUND SNOW, PG = 60 PSF
IMPORTANCE FACTOR = I = 0.8
THERMAL FACTOR Ct = 1.20 EXPOSURE FACTOR, Ce = 1.0 FLAT ROOF SNOW, Pf = 40.3 PSF
WINDWARD UNBALANCED SNOW = 12.1 PSF
LEEWARD UNBALANCED SNOW NEAR RIDGE = 63.9 PSF
LEEWARD UNBALANCED SNOW NEAR EAVE = 40.3 PSF
WIND:
WIND LOAD: ENVELOPE PART 2 SIMPLE DIAPHRAGM LOW-RISE
ULTIMATE DESIGN WIND SPEED, Vult = 105 MPH NOMINAL DESIGN WIND SPEED, Vasd = 82 MPH
EXPOSURE CATEGORY.....B
INTERNAL PRESSURE COEFFICIENT ....+/- 0.18
TOPOGRAPHIC FACTOR …..Kzt = 1.0 DIRECTIONALITY FACTOR……Kd = 0 .85 MWFRS BASE PRESSURE…..qh = 16.8 PSF COMPONENTS AND CLADDING: PART 1 LOW-RISE…..qh = 16.8 PSF
BUILDING SUPPLIER SHALL SUBMIT SEALED STRUCTURAL CALCULATIONS FOR WIND
LOAD DESIGN OF MAIN LATERAL WIND FORCE RESISTING SYSTEM ALONG WITH ANY
CHANGES NECESSARY FOR THE DRAWINGS PRIOR TO BEGINNING WORK OR ORDERING
MATERIALS.
GENERAL
1. THESE NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. SEE SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
2. THESE DRAWINGS REPRESENT THE COMPLETED PROJECT WHICH HAS BEEN DESIGNED FOR THE
DEAD LOAD WEIGHT OF MATERIALS INDICATED PLUS THE SUPERIMPOSED LIVE LOADS
INDICATED IN THE DESIGN DATA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
ALLOWABLE CONSTRUCTION LOADS AND TO PROVIDE PROPER DESIGN AND CONSTRUCTION OF
FALSEWORK, FORMWORK, STAGING, BRACING, AND SHORING. CONTRACTOR HAS SOLE
RESPONSIBILITY FOR CONSTRUCTION MEANS AND METHODS, SEQUENCES, AND PROCEDURES
OF CONSTRUCTION. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM, WITH
COMPLETED CONNECTIONS, AND FIELD INSTALLED MATERIALS HAVING REACHED SPECIFIED
DESIGN STRENGTH.
3. DEFERRED SUBMITTALS: PORTIONS OF THE DESIGN HAVE BEEN DEFERRED AND WILL BE
DESIGNED BY PRODUCT MANUFACTURERS QUALIFIED LICENSED ENGINEERS. THE STRUCTURAL
ENGINEER OF RECORD WILL ONLY REVIEW SUBMITTALS OF THESE SYSTEMS FOR GENERAL
CONFORMANCE WITH THE PROJECT PARAMETERS INDICATED AND IS NOT RESPONSIBLE FOR
DEFERRED SUBMITTAL DESIGN. DEFERRED SUBMITTALS INCLUDE:
METAL PLATE CONNECTED WOOD TRUSSES
GENERAL CONDITIONS
1. OBTAIN ALL NECESSARY STATE AND LOCAL PERMITS. WORK SHALL COMPLY WITH ALL LOCAL
ORDINANCES INCLUDING BUT NOT LIMITED TO WORKING HOURS, NOISE LEVELS, DUST, ETC.
FOUNDATIONS
1. LOCATE ALL UNDERGROUND UTILITIES BEFORE STARTING WORK. CONTACT UTILITYLOCATING SERVICES PRIOR TO EXCAVATION. IN MICHIGAN CALL "MISS DIG" 800-482-7171 AT LEAST 72
HOURS PRIOR TO STARTING WORK.
2. FOUNDATION DESIGN IS BASED ON THE SOILS INVESTIGATION REPORT NUMBER 082428.00 BY
ANDREW BOLTON, SME; DATED AUGUST 27, 2019.
3. FOUNDATIONS SHALL BEAR ON SOILS HAVING A MINIMUM ALLOWABLE BEARING PRESSURE OF
2500 PSF FOR SHALLOW CIRCULAR DRILLED CONCRETE PIERS.
CONCRETE
1. ALL MATERIAL AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH AMERICAN CONCRETE
INSTITUTE (ACI) DOCUMENTS REFERENCED IN SPECIFICATIONS.
2. MATERIAL PROPERTIES:
LOCATION 28 DAY f'c AIR CONTENT MAX SLUMP
SPREAD FOOTINGS 3000 PSI NO TEST 4” MAX
SIDEWALKS, DRIVES, AND 4000 PSI 6%+1% 4” MAX
ALL CONCRETE EXPOSED
TO WEATHER
INTERIOR SLABS-ON-GRADE 3500 PSI NO TEST 4” MAX
REINFORCING BARS: ASTM A615 GRADE 60 UNLESS NOTED OTHERWISE
TIES AND STIRRUPS ASTM A615 GRADE 40
3. ALL CONCRETE SHALL BE CURED FOR A MINIMUM OF 7 DAYS. IF FORMS ARE REMOVED BEFORE
THE END OF CURING PERIOD, COAT SURFACES WITH LIQUID CURING COMPOUND.
WOOD
1. LUMBER SHALL CONFORM TO STANDARD GRADING RULES OF WWPA OR NELMA, PLYWOOD
SHALL CONFORM TO APA.
2. APPLICATION SPECIES SIZE GRADE MIN. FB (PSI)MIN. E (KSI)
BEAMS, & HEADERS S PINE 2X10 NO.2 FB=800 1,400
S PINE 2X8, 2X6 NO.2 FB=925 1,400
HEM FIR ALL 2X NO.2 FB=850 1,300
SPF(S) ALL 2X NO.2 FB=775 1,100
BEARING STUDS S PINE 2X4, 2X6 NO.2 FC=1,400 1,400
HEM FIR 2X4, 2X6 NO.2 FC=1,300 1,300
SPF(S) 2X4, 2X6 NO.2 FC=1,000 1,100
TIMBER COLUMNS S PINE 6X6 NO.2 FC=525 1,200
(5 ½”X5 ½”)
ROOF DECKING: 7/16" PLYWOOD - APA SHEATHING, 24/16 C-D, EXP. 1
LVL E=2,000,000 PSI FB=2,600 PSI
(LAMINATED VENEER LUMBER)
3. INSTALL ROOF DECKING WITH FACE GRAIN PERPENDICULAR TO SUPPORTS WITH 1/8" GAP AT
PANEL JOINTS. FASTEN WITH 8D COMMON NAILS AT 6" OC ALONG PANEL EDGES AND 12" OC
ALONG INTERMEDIATE SUPPORTS.
4. REGARDLESS OF NAIL TYPE OR NAILING METHOD PROVIDE MINIMUM SHANK DIAMETER AS
FOLLOWS: 6d=0.113”, 8d=0.131”, 10d=0.148”, 16d=0.162”, 20d=0.192”
5. PRESSURE TREATMENT: PROVIDE PRESERVATIVE PRESSURE TREATED WOOD AS INDICATED
AND WHERE IN CONTACT WITH CONCRETE, MASONRY, OR EXPOSED TO EARTH OR WEATHER.
AWPA U1 USING; AMMONIACAL COPPER ZINC ARSENATE (ACZA), AMMONIACAL OR AMINE
COPPER QUAT (ACQ), OR AMMONIACAL COPPER CITRATE (ACC).
TREAT ALL WOOD PER AWPA STANDARD C-2 AS FOLLOWS: 1) ABOVE GROUND USE PROVIDE
.25 POUND PER CUBIC FOOT OF WOOD. 2) BELOW GROUND USE PROVIDE .40 POUND PER
CUBIC FOOT OF WOOD.
PREFABRICATED METAL PLATE WOOD TRUSSES
1. PROVIDE PREFABRICATED METAL-PLATE CONNECTED WOOD TRUSSES DESIGNED AND
CERTIFIED BY AN ENGINEER, LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED, TO
SUPPORT THE SUPERIMPOSED DEAD AND LIVE LOADS INDICATED.
2. TRUSSES SHALL BE DESIGNED FOR THE INDICATED LIVE AND DEAD LOADS PLUS THE DEAD
WEIGHT OF THE TRUSSES:
A. TOP CHORD: DEAD LOAD = 10 PSF
BALANCED SNOW = 40.3 PSF
UNBALANCED SNOW LEEWARD SIDE = 63.9 PSF (FROM RIDGE TO 8.67')
UNBALANCED SNOW LEEWARD SIDE = 40.3 PSF (FROM 8.67' TO EAVE)
UNBALANCED SNOW WINDWARD SIDE = 12.1 PSF
B. BOTTOM CHORD: DEAD LOAD=5 PSF
CONCENTRATED LOAD OF 300 POUNDS AT ANY POINT ALONG BOTTOM CHORD
DESIGN LOADS SHALL BE ADJUSTED FOR SNOW DRIFT AND SLIDING SNOW LOAD
WHERE APPLICABLE.
C. SNOW DRIFT LOADS INDICATED
3. TRUSSES SHALL BE DESIGNED FOR THE FOLLOWING DEFLECTION CRITERIA:
A. ROOF TRUSSES: VERTICAL TOTAL LOAD DEFLECTION OF L/240
B. ROOF TRUSSES: VERTICAL LIVE LOAD DEFLECTION OF L/360
4. COMPLY WITH APPLICABLE REQUIREMENTS AND RECOMMENDATIONS OF THE TRUSS PLATE
INSTITUTE (TPI) AND APPLICABLE REQUIREMENTS OF NATIONAL FIRE PROTECTION ASSOCIATION
(NFPA) PUBLICATION "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION."
5. ERECT AND BRACE TRUSSES TO COMPLY WITH APPLICABLE REQUIREMENTS OF REFERENCED
TPI STANDARDS.
6. PROVIDE (1) SIMPSON H2.5A TIE AT EACH ROOF TRUSS AND RAFTER BEARING.
SPECIAL INSPECTIONS (PER MBC 2015 - SECTIONS 1704-1705)
1. BUILDING PERMIT APPLICANT SHALL SUBMIT NAME, ADDRESS, AND CONTACT INFORMATION FOR
EACH PROPOSED SPECIAL INSPECTOR INDICATED AT THE TIME OF PERMIT APPLICATION.
SPECIAL INSPECTIONS ARE TO BE ARRANGED FOR BY THE GENERAL CONTRACTOR OR
CONSTRUCTION MANAGER BUT SHALL HAVE A CONTRACT DIRECTLY WITH THE OWNER. SPECIAL
INSPECTIONS ARE REQUIRED FOR THE FOLLOWING:
A. FABRICATOR'S SHOP
WOOD TRUSS FABRICATOR'S SHOP (SEC. 1704.2.5)*
* NOTE THAT SPECIAL INSPECTION IS NOT REQUIRED FOR THE FABRICATOR'S
SHOP IF CERTIFICATE OF COMPLIANCE IS SUBMITTED BY THE FABRICATOR'S
INSPECTION AGENCY PER 1704.2.5.1.
B. SOILS
SOIL BEARING CAPACITY (TABLE 1705.6 - #1)
GENERAL NOTES, PROJECT REQUIREMENTS, AND SPECIFICATIONS:
STRUCTURAL NOTES, REQUIREMENTS, AND SPECIFICATIONS:
PROJECT
REQUIREMENTS
AND NOTES
A0
REVISIONS:
MMA JOB # 19111
SET DATE
CURRENT ISSUE:
REVIEW:
ARCHITECT
OWNER
CHECKED BY: INITIALS
PROJECT MANAGER TRM
JNM
SOM DTMB:
© MATHISON | MATHISON ARCHITECTS
NE
W
S
TO
RA
GE
F
AC
IL
IT
Y
AT
E.
C.
B
RO
OK
S
CO
RR
EC
TI
ON
AL
F
AC
IL
IT
Y
S
S
HE
RI
DA
N
DR
, M
US
KE
GO
N, M
I 4
DRAWING TITLE:
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FILE NO: 472-18412-GAG
INDEX NO: 472LRFMaintProj
ISID CONTRACT NO: 00815
DEPT. OF CORRECTIONS
BIDDING 10/01/19
PLAN REVIEW 09/19/19
BIDDING 10/01/19
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M jeffm Stamp
'-0
40'-0"
10'-6"
8'-0"
5' -4
'-0
'-0
5'
-4
A D
JA
C
E N
T M
A
IN
TE
N
A N
C E
B U
IL
D
IN
G
'-0
5'
-4
E Q
E Q
8'-0"8'-0"
5' x 5' CONCRETE PAD
ALTERNATE NO.1:
6' WIDE X 38' LONG
CONCRETE APRON;
SLOPE @ 14" PER FOOT
5' x 5' CONCRETE PAD;
CONNECT TO EXISTING
ADJACENT SIDEWALK
8'-0" 8'-0"
NOTE:
· PROVIDE
SMOOTH-TROWEL
FINISH FOR INTERIOR
CONCRETE SLAB
· PROVIDE NON-SLIP
BROOM FINISH FOR
EXTERIOR CONCRETE
(INCLUDING APRON)
SLOPE DN
PRECAST CONCRETE SPLASH
BLOCK; TYP. OF (4), ONE
EACH AT BUILDING CORNER
' X
4'
O V
E R
H E
A D
D O
O R
(F
IN
IS
H
E D
O P
E N
IN
G
, C
LE
A R
3' x 7'
HOLLOW
METAL DOOR
' X
0'
O V
E R
H E
A D
D O
O R
(F
IN
IS
H
E D
O P
E N
IN
G
, C
LE
A R
3' x 7'
HOLLOW
METAL DOOR
' X
4'
O V
E R
H E
A D
D O
O R
(F
IN
IS
H
E D
O P
E N
IN
G
, C
LE
A R
5' -4
5' -4
5'
-4
5' -4
5'
-4
5' -4
5'
-4
5' -4
5'
-4
5' -4
PROVIDE SUPPLEMENTAL FRAMING FOR
DOOR FRAMES AND MOUNTING AT ALL DOOR
OPENINGS; FILL VOID SPACE BETWEEN
PRIMARY POLE STRUCTURE AND DOOR
FRAME/JAMB COMPONENTS AS REQUIRED
TO PROVIDE SECURE INSTALLATION OF
FRAMES AND JAMBS AROUND OPENINGS
AND DOOR HEADERS; TYP. ALL OPENINGS
TRUSS SPAN DIRECTION
SLOPE FLOOR SLAB DOWN 18" PER FT.
ALLOW MINIMUM OF 8' OF WALL
BETWEEN BUILDING CORNER AND
OVERHEAD DOOR OPENING FOR
BUILDING FRAME CORNER BRACING
PROVIDE (1) 1.75" x 11.87" LVL EACH SIDE OF POST w/ (24) 16d COMMON NAILS EACH; TYP.
EACH OVERHEAD DOOR OPENING
ANTICIPATED LOCATION
OF DOWNSPOUT
ROUTE DOWNSPOUT TO
GABLE END OF BUILDING
HOLLOW
METAL DOOR
EXISTING ADJACENT
MAINTENANCE BUILDING
ENGINEERED TRUSS @ 2'-0" O.C.
2X LATERAL WOOD BRACING
AS REQUIRED BY
ENGINEERED TRUSS MFR.
2 x GIRTS (TREATED AWPA UC3B) AT
24" O.C. PER BUILDING CODE REQ.
6" x 6" STRUCTURAL BUILDING
COLUMNS @ 5'-4" O.C.; PRESSURE
PRESERVATIVE TREATED FOR
IN-GROUND USE/GROUND
CONTACT (AWPA UC4B)
PRESSURE PRESERVATIVE TREATED
8" SKIRT BOARD (AWPA UC4B),
CONTINUOUS AROUND BUILDING
PERIMETER EXCLUSIVE OF DOOR
OPENINGS
24" DIA. CONCRETE COLUMN FOOTING;
PROVIDE 36" DIA. AT OVERHEAD DOORS
10" DEEP PRECAST CONCRETE OR
EQUIVALENT UPLIFT PROTECTION
2" x 6" TREATED (AWPA UC4B)
HOLD-DOWN CLEATS, UPLIFT PLATE, OR
EQUIVALENT UPLIFT PROTECTION AT
EACH COLUMN
6" 4000 PSI CONCRETE FLOOR SLAB
REINFORCED W/ WELDED WIRE FABRIC
ON VAPOR BARRIER (10 MIL MIN.) ON
6" SAND-GRAVEL SUB-BASE (MDOT 21AA)
COMPACTED TO 95% DRY DENSITY
ASPHALT SHINGLE ROOFING ON 7/16" OSB
ROOF SHEATHING W/ 15# CONT. FELT AND
6' CONT. ICE/WATER SHIELD AT EAVES
29g EXTERIOR METAL SIDING PANELS
SLOPE TOP OF CONCRETE FOOTING
OR FORM FOR POSITIVE DRAINAGE
'-0
ALUMINUM VENTED SOFFIT
4' -0
" M
IN
PREFINISHED 6" ALUMINUM SEAMLESS
GUTTER & DOWNSPOUT SYSTEM
6'-0"ICE/WATER SHIELD
T.O. SLAB AT H.P.
640.5
B.O. EAVE
1'-0" PRE-FINISHED ALUMINUM FASCIA
6" 6"
6" M
IN
HURRICANE TIES AS REQUIRED AT
FRAMING CONNECTIONS
2" x 12" SYP w/ (12) 18d
COMMON NAILS OR
EQUIVALENT CONT. CARRIER
PER BUILDING CODE
REQUIREMENTS
18" DEEP TURNED
DOWN SLAB EDGE OR
EQUIVALENT RODENT
BURROWING AND
EROSION PROTECTION
BUILDING FRAMING NOTE:
STRUCTURAL LAYOUT AND FRAMING
STRATEGIES OTHER THAN THOSE SHOWN ON
THE DRAWINGS WILL BE CONSIDERED ONLY
WITH THE INCLUSION OF COMPLETE
STRUCTURAL CALCULATIONS; ENGINEERED
FRAMING PLAN AND DETAILS; AND SUPPORTING
DOCUMENTS FOR REVIEW AND COMPARISON.
INCLUDE SCHEDULE OF PRICING COMPARISON
FOR EACH STRATEGY SUBMITTED INCLUDING
THAT WHICH IS SHOWN IN THE BID DOCUMENTS.
'-0
10' X 14'
OVERHEAD
DOOR
10' X 10'
OVERHEAD
DOOR
10' X 14'
OVERHEAD
DOOR
EXISTING BUILDING
BEYOND
EXISTING DOOR FROM
EXISTING ADJACENT
MAINTENANCE BUILDING
ANTICIPATED LOCATION
OF DOWNSPOUT
7' -8
ANTICIPATED LOCATION
OF DOWNSPOUT
ROUTE DOWNSPOUT TO
GABLE END OF BUILDING
AT NORTHEAST CORNER
EXISTING BUILDING
BEYOND FLOOR PLAN
AND DETAILS
A12
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"
WEST ELEVATION
SCALE: 1/8" = 1'-0"
WALL SECTION
SCALE: 1/2" = 1'-0"
FLOOR PLAN
SCALE: 1/8" = 1'-0"
N
A1
A1
A1
PROJECT DEDUCT ALTERNATES (REFER TO SPECIFICATION FOR ADDITIONAL INFORMATION):
ALTERNATE 1: REPLACE THE CONCRETE APRON AT THE OVERHEAD DOORS WITH
A DOLOMITE OR GRAVEL APRON.
ALTERNATE 2: OMIT GUTTERS AND DOWN SPOUTS AND ASSOCIATED ROOF
DRAINAGE SYSTEM COMPONENTS (I.E. SPLASHBLOCKS,
FASTENERS, MOUNTING HARDWARE, ETC.) SHOWN ON THE
BUILDING DRAWINGS.
ALTERNATE 3: PROVIDE UN-INSULATED DOORS IN LIEU OF INSULATED DOORS FOR
THE OVERHEAD DOORS SHOWN.
REVISIONS:
MMA JOB # 19111
SET DATE
CURRENT ISSUE:
REVIEW:
ARCHITECT
OWNER
CHECKED BY: INITIALS
PROJECT MANAGER TRM
JNM
SOM DTMB:
© MATHISON | MATHISON ARCHITECTS
NE
W
S
TO
RA
GE
F
AC
IL
IT
Y
AT
E.
C.
B
RO
OK
S
CO
RR
EC
TI
ON
AL
F
AC
IL
IT
Y
S
S
HE
RI
DA
N
DR
, M
US
KE
GO
N, M
I 4
DRAWING TITLE:
D
EP
A R
TM
EN
T O
F
TE
C H
N O
LO
G
Y , M
A N
A G
EM
EN
T A
N D
B U
D G
ET
ST
A
TE
O
F M
IC
H
IG
A
N
FA
C
IL
IT
IE
S
A N
D B
U
SI
N
ES
S
SE
R V
IC
ES
A D
M
IN
IS
TR
A
TI
O N
D
ES
IG
N
A N
D C
O N
ST
R
U C
TI
O
N D
IV
IS
IO
N
R O
B
ER
T C
. H A
LL
, R
A , N
C A
R B
, D
IR
EC
TO
R
FILE NO: 472-18412-GAG
INDEX NO: 472LRFMaintProj
ISID CONTRACT NO: 00815
DEPT. OF CORRECTIONS
BIDDING 10/01/19
PLAN REVIEW 09/19/19
BIDDING 10/01/19
AutoCAD SHX Text P
AutoCAD SHX Text L
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text B
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text N
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text Q
AutoCAD SHX Text U
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text S
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text A
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text M jeffm Stamp
File details come from the government source that posted it. Updated .