This document is a comprehensive set of architectural and engineering design plans for a roof replacement project at the Central School facility located at 26501 Avenue 140 in Porterville, California, operated by the California Department of General Services on behalf of Developmental Services. The project involves removing the existing roofing system and related accessories down to the structural deck, including abatement of hazardous materials as necessary, and replacing it with a new roofing system comprising rigid insulation, cover board, single-ply membrane, rooftop fall protection system, and all required flashing. The scope includes removal of two existing skylights and replacement with wood-framed deck and sheathing, removal and replacement of gutters and downspouts, and removal and reinstallation of mechanical equipment with new raised curbs and flashing. The project encompasses approximately 29,550 square feet of roof area across seven building sections (E1 through E7) at the single-story facility constructed in 1951. The design documents include 20 total sheets covering general, architectural, mechanical, and electrical disciplines with detailed specifications, legends, and installation notes conforming to 2022 California Building Code, California Fire Code, and applicable NFPA standards.
The project documentation establishes conformance requirements with multiple applicable codes including Title 24 CCR provisions, Title 19 CCR fire safety regulations, and industry standards such as NFPA 13, 14, 17, 20, 22, 24, 72, and 80 for fire protection systems. The design team is led by Project Manager Amy Smith with Architecture by Edgar Reyes, Mechanical by Nick Gasparro, and Electrical by Scott Wheeler of The Engineering Enterprise. Key project constraints include maintaining the building as occupied and operational during construction with all rooftop equipment and devices remaining functional, maintaining a minimum 20-foot-wide emergency vehicle access roadway with 13-foot-6-inch vertical clearance per California Fire Code requirements, and implementing a construction staging area on South Circle Drive. The existing building, originally constructed as Type V under 1949 UBC standards with 18,000 square feet of area and an occupant load of 134, is no longer used as a school and now houses administrative offices. State Fire Marshal Permit No. 25-S-2521 was issued with an effective date of July 31, 2027, and the plans were issued for bid on October 9, 2025.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
13 12 12 12
2 2
NO
PAR K I NG
PROJECT MANAGER: AMY SMITH
AMY.SMITH@DGS.CA.GOV
ARCHITECTURE: EDGAR REYES
EDGAR.REYES@DGS.CA.GOV
MECHANCIAL: NICK GASPARRO
NICK.GASPARRO@DGS.CA.GOV
ELECTRICAL: SCOTT WHEELER
THE ENGINEERING ENTERPRISE
SCOTT@ENGENT.COM
PROJECT LOCATION
PROJECT LOCATION
26501 AVENUE 140
PORTERVILLE, CA 93258
PORTERVILLE, TULARE COUNTY
WORTH AVE.
H
IL
L C
R E
S T
S T
R O
A D
P L A
N O
S T
CAMPUS MAP
SEQUENCE DESIGNATOR
SUBSET DESIGNATOR
SHEET TYPE DESIGNATOR
DISCIPLINE DESIGNATOR
EXAMPLE:
G - GENERAL
C - CIVIL
A - ARCHITECTURE
S - STRUCTURAL
EXAMPLE:
0 - GENERAL
1 - PLANS
EXAMPLE:
0 - SITE
1 - DEMOLITION
SHEET INDEX LEGEND
2 - FLOOR
# - ETC
2 - ELEVATIONS
# - ETC
M - MECHANICAL
P - PLUMBING
E - ELECTRICAL
X - ETC
PROJECT TEAMSHEET INDEXAPPLICABLE CODES
PARTIAL LIST OF APPLICABLE CODES
2022 CALIFORNIA ADMINISTRATIVE CODE (CAC), PART 1, TITLE 24 CCR
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 CCR
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 CCR
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 CCR
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 CCR
2022 CALIFORNIA ENERGY CODE (CEC), PART 6, TITLE 24 CCR
2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24 CCR
2022 CALIFORNIA EXISTING BUILDING CODE (CEBC), PART 10, TITLE 24 CCR
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN), PART 11, TITLE 24 CCR
2022 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24 CCR
TITLE 19 CCR, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS
2019 ASME A17.1/CSA B44-16 SAFETY CODE FOR ELEVATORS AND ESCALATORS
PARTIAL LIST OF APPLICABLE STANDARDS
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (CA
AMENDED) -- 2025 EDITION
NFPA 14 STANDARD FOR THE INSTALLATION OF STANDPIPE AND HOSE SYSTEMS (CA
AMENDED) --2024 EDITION
NFPA 17 STANDARD FOR DRY CHEMICAL EXTINGUISHING SYSTEMS -- 2024 EDITION
NFPA 17A STANDARD FOR WET CHEMICAL EXTINGUISHING SYSTEMS -- 2024 EDITION
NFPA 20 STANDARD FOR THE INSTALLATION OF STATIONARY PUMPS FOR FIRE
PROTECTION -- 2025 EDITION
NFPA 22 STANDARD FOR WATER TANKS FOR PRIVATE FIRE PROTECTION -- 2023
EDITION
NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND
THEIR APPURTENANCES (CA AMENDED) -- 2025 EDITION
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE (CA AMENDED) -- 2022 EDITION
NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES - 2025
EDITION
NFPA 2001 STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS (CA
AMENDED) - 2018 EDITION
UL 300 STANDARD FOR FIRE TESTING OF FIRE EXTINGUISHING SYSTEMS FOR
PROTECTION OF COMMERCIAL COOKING EQUIPMENT-- 2005 (REV. 2014)
UL 464 AUDIBLE SIGNALING DEVICES FOR FIRE ALARM AND SIGNALING SYSTEMS,
INCLUDING ACCESSORIES -- 2023 EDITION
UL 521 STANDARD FOR HEAT DETECTORS FOR FIRE PROTECTIVE SIGNALING
SYSTEMS -- 1999 EDITION
FOR A COMPLETE LIST OF APPLICABLE NFPA STANDARDS REFER TO 2019 CBC (SFM)
CHAPTER 35 AND CALIFORNIA FIRE CODE (CFC) CHAPTER 80.
SEE CALIFORNIA BUILDING CODE, CHAPTER 35, FOR STATE OF CALIFORNIA AMENDMENTS
TO THE NFPA STANDARDS
AMERICANS WITH DISABILITIES ACT 2010 STANDARDS INCLUDING:
• TITLE II REGULATIONS AT 28 CFR PART 35.151 AND;
• 2004 AMERICANS WITH DISABILITIES ACT ACCESSIBLE GUIDELINES (ADAAG) AT 36
CFR PART 1191 APPENDICES D AND C
WHERE THESE TWO DIFFER, 28 CFR PART 35.151 SHALL PREVAIL
BUILDING INFORMATION SHEET INDEX LEGEND PROJECT SCOPE
REMOVE EXISTING ROOFING SYSTEM AND RELATED ACCESSORIES DOWN TO STRUCTURAL
DECK, ABATEMENT OF HAZARDOUS MATERIALS AS NECESSARY. REPLACE WITH NEW
ROOFING SYSTEM INCLUDING RIGID INSULATION, COVER BOARD, A SINGLE-PLY
MEMBRANE, ROOFTOP FALL PROTECTION SYSTEM, AND ALL REQUIRED FLASHING. INSTALL
NEW EQUIPMENT CURBS AS NECESSARY. REMOVE EXSITING SKYLIGHTS (2) AND REPLACE
WITH WOOD FRAMED DECK AND SHEATHING. ALL WORK SHALL CONFORM TO THE DETAILS
SHOWN AND THE ROOFING MEMBRANE MANUFACTURER'S STANDARD INSTALLATION
DETAILS.
THE SCOPE OF PROJECT DOES NOT CHANGE EGRESS, OCCUPANCY, WALLS, OR EXISTING
FLOOR PLAN. THERE IS NO CHANGE TO BUILDING LAYOUT OR EXPANSION OF BUILDING.
BUILDING IS NO LONGER USED AS SCHOOL AND NOW HOUSES OFFICES.
TOTAL : 20 SHEETS
CENTRAL SCHOOL
SCALE 1" = 400'
NONSTRUCTURAL PROVISIONS
OCCUPANCY GROUPS AND VARIED USES:B ( E AT TIME OF CONSTRUCTION PER 1949 UBC)
BUILDING CONSTRUCTION TYPE:VB (CONSTRUCTED AS TYPE V UNDER 1949 UBC)
NUMBER OF STORIES:01
ACTUAL BUILDING HEIGHT:12' 10"
BUILDING AREA IN SQUARE FEET:18,000
AREA OF PROJECT IN SQUARE FEET:29,550 (ROOF REPLACEMENT)
SEPARATED, NON-SEPARATED, ACCESSORY USE:NON-SEPARATED
ALLOWABLE AREA:18,000 S.F.
AREA INCREASE:NONE
HEIGHT INCREASE: NONE
FIRE SPRINKLERS (TYPE, FULL, PARTIAL):NONE
FIRE ALARM (TYPE):MANUAL, ADDRESSABLE
OTHER FIRE PROTECTION SYSTEM (TYPE):NONE
SMOKE CONTROL SYSTEM (Y/N):N
OCCUPANT LOAD FOR ENTIRE BUILDING AND EACH FLOOR:134
YEAR BUILDING WAS CONSTRUCTED:1951
HIGH FIRE HAZARD SEVERITY ZONE (Y/N):N
SEISMIC JOINTS AND LOCATIONS:NONE
EMERGENCY RESPONDER RADIO COVERAGE (Y/N):YES
GENERAL
G001 COVER SHEET
G002 ARCHITECTURAL COVER SHEET
G010 ILLUSTRATIVE SITE & DEMO PLAN
G020 (E) SITE IMAGERY
ARCHITECTURAL
A021 AS-BUILT REFERENCE DRAWINGS
A022 AS-BUILT REFERENCE DRAWINGS
A131 ROOF PLAN
A531 ROOFING DETAILS
MECHANICAL
M001 MECHANICAL LEGENDS AND NOTES
M100 OVERALL ROOF PLAN
M141 MECHANICAL ROOF PLAN BUILDING E5
M142 MECHANICAL ROOF PLAN BUILDING E4
M143 MECHANICAL ROOF PLAN BUILDING E6
M144 MECHANICAL ROOF PLAN BUILDING E3
M145 MECHANICAL ROOF PLAN BUILDING E7
M146 MECHANICAL ROOF PLAN BUILDING E1 & E2
M600 MECHANICAL DETAILS
ELECTRICAL
E001 GENERAL NOTES, SYMBOLS AND DETAILS
E201 ELECTRICAL ROOF PLAN - CENTRAL SCHOOL
E202 ELECTRICAL ROOF PLAN - CENTRAL SCHOOL
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
G001
LH ER ER
NA
COVER SHEET
000000000012027E
AS NOTED
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
DEVELOPMENTAL SERVICES
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DDS PORTERVILLE ROOF REPLACEMENT - CENTRAL SCHOOL
PROJECT NUMBER: 000000000012027E
V1
NORTH
No. Date Description
SFM Permit No
25-S-2521
07/31/27
07-28-25
ISSUE DATE: OCTOBER 9, 2025
D
ROOM NAME
AND NUMBER
DOOR NUMBER
WINDOW TYPE
KEYNOTE REFERENCE
NORTH ARROW
GRID LINE
WALL TYPE (SEE A611) 1S4A
REVISION CLOUD
(EXTENT OF REVISION)
SECTION REFERENCE
SECTION NUMBER
SHEET NUMBER
CENTERLINE
BREAK LINE
MATCH LINE
ELEVATION MARK
OR DATUM POINT
DETAIL REFERENCE
INTERIOR ELEVATION REFERENCE
ELEVATION NUMBER
SHEET NUMBER
ALIGN SURFACES
REVISION IDENTIFIER
T.O.PARAPET
24'-0"
OFFICE
1t
A221
EXTERIOR ELEVATION REFERENCE A2111
E A
S T
ARCHITECTURAL SYMBOLS
A5.1
A5.1
01-01SIGNAGE REFERENCE
EARTH
POROUS FILL
CONCRETE
CONCRETE BLOCK
BRICK
METAL
CONTINUOUS WOOD
SHIM OR NON-CONT. WOOD BLKING
FINISH WOOD
PLYWOOD
GYPSUM WALLBOARD
STONE
RIGID INSULATION
BATT INSULATION
ACOUSTIC TILE
PLASTER ON METAL LATH
TILE
SEALANT W/ BACK-UP MATERIAL
ARCHITECTURAL MATERIALS GENERAL NOTES
1. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS THAT THE WORK OF THE CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT. WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CALIFORNIA BUILDING CODE AND ALL OTHER GOVERNING AUTHORITIES HAVING JURISDICTION (AHJ).
2. THE CONTRACTOR IS TO FIELD VERIFY ALL DIMENSIONS AND NOTIFY THE STATE REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF
WORK, IF SITE / FIELD CONDITIONS ARE FOUND TO BE DIFFERENT FROM THE DRAWINGS.
3. PROTECT ALL UTILITY LINES DURING CONSTRUCTION. IF DISCONNECTION IS REQUIRED COORDINATE WITH THE STATE PRIOR TO WORK.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECONNECTION FOR A FULLY OPERATIONAL SYSTEM.
4. ALL DIMENSIONS SHOWN ARE EXISTING CONDITIONS. DO NOT SCALE FROM DRAWINGS, FIGURED DIMENSIONS GOVERN OVER NOMINAL
DIMENSIONS.
5. ALL HEIGHTS ARE DIMENSIONED FROM FINISHED FLOOR, (U.O.N.)
6. "TYPICAL" OR "TYP." SHALL INDICATE STANDARD FOR OTHER LIKE CONDITIONS THROUGHOUT THE WORK.
7. "SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. VERIFY DIMENSIONS AND ORIENTATION ON PLAN
AND/OR ELEVATIONS.
8. THE CONTRACTOR SHALL, AT ALL TIMES DURING THE COURSE OF THE WORK, KEEP THE CONSTRUCTION AREA, THE STATE PREMISES, INCLUDING STREETS AND OTHER AREAS USED BY THE CONTRACTOR, CLEAN AND FREE FROM ACCUMULATION OF WASTE MATERIALS AND RUBBISH. THE CONTRACTOR SHALL PROVIDE DUST CONTROL MEASURES AS REQUIRED. AT THE COMPLETION OF THE WORK, REMOVE FROM THE BUILDING AND THE PREMISES ALL SURPLUS MATERIALS AND DEBRIS, AND CLEAN THE SITE THOROUGHLY TO THE
SATISFACTION OF THE STATE.
9. FACILITIES HANDLING, STORING, SELLING, AND USING HAZARDOUS, COMBUSTIBLE, OR FLAMMABLE MATERIALS SHALL COMPLY WITH THE
APPLICABLE SECTIONS OF THE CALIFORNIA FIRE CODE.
10. DISCOVERY OF DETERIORATING AND NON-CONFORMING CONDITIONS WILL BE BROUGHT TO THE ATTENTION OF THE STATE.
CORRECTIVE WORK WILL BE PERFORMED AS DIRECTED BY THE STATE.
11. GENERAL NOTES SHALL APPLY TO THE ENTIRE WORK UNDER THIS CONTRACT.
12. ALL CONSTRUCTION WORK: ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, ETC. SHALL BE CARRIED OUT IN ACCORDANCE WITH ALL CODES, RULES, AND REGULATIONS GOVERNING CONSTRUCTION AND THE USE OF FACILITIES AS SET BY STATE CODES.
13. ALL SURFACES OF NEW CONSTRUCTION SHOULD BE PAINTED OR APPLIED FINISH MATERIALS PER CONSTRUCTION DOCUMENTS OR
MANUFACTURER'S RECOMMENDATION.
14. THE CONTRACTOR SHALL VERIFY SITE CONDITION AND FEASIBILITY OF INSTALLATION BEFORE PROCURING PRODUCTS. SUBMITTALS
ARE REQUIRED FOR REVIEW.
ARCHITECTURAL ABBREVIATIONS
NOTE: ADDITIONAL AND OR VARIED ABBREVIATIONS MAY BE FOUND IN OTHER DISCIPLINES. IF THERE IS A CONFLICT, ABBREVIATIONS IDENTIFIED IN OTHER DISCIPLINES DICTATE WHITHIN THE APPLICABLE DISCIPLINE DRAWINGS.
℄ CENTERLINE
⌀ DIAMETER OR ROUND
# NUMBER
AC ASPHALT CONCRETE
ACC ACCESSORY
ACM ASBESTOS CONTAINING MATERIAL
ACT ACOUSTIC CEILING TILE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
AR ACCESSIBLE ROUTE
ARCH ARCHITECTURAL
ASB ASBESTOS
AVG AVERAGE
B BASE
BD BOARD
BLDG BUILDING
BO BOTTOM OF
BOT BOTTOM
C DEGREE CELCIUS
CATV CABLE TELEVISION
CCTV CLOSED-CIRCUIT TELEVISION
CF CUBIC FEET
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CJ CONTROL JOINT
CI CAST IRON
CLR CLEAR
CLG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
COMM COMMUNICATION
COMP COMPOSITION
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUATION OR CONTINUOUS
CORR CORRIDOR
CP CARPET
CS CONC SEALER
CT CERAMIC TILE
DBL DOUBLE
DEPT DEPARTMENT
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DISP DISPENSER
DN DOWN
DR DOOR
DS DOWNSPOUT
DTL DETAIL
DW DISH WASHER
DWG DRAWING
E EAST
(E) EXISTING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EXP EXPANSION
EXPSD EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAB FABRIC
FACP FIRE ALARM CONTROL PANEL
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FG FINISH GRADE
FLR FLOOR
FLRG FLOORING
FLS FIRE LIFE SAFETY
FO FACE OF
FOF FACE OF FINISH
FOS FACE OF STUD
FRP FIBERGLASS REINFORCED PLASTIC
FRZR FREEZER
FS FIRE SUPPRESSION
FT FOOT OR FEET
FTG FOOTING
FV FIELD VERIFY
GA GAUGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GI GALVANIZED IRON
GL GLASS
GSM GALVANIZED SHEET METAL
GSP GALVANIZED STEEL PIPE
GWB GYPSUM WALL BOARD
GYP GYPSUM
GYPBD GYPSUM BOARD
HB HOSE BIBB
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION, AND AIR CONDITIONING
ID INSIDE DIAMETER
IN INCH
INSUL INSULATION
INT INTERIOR
JB JUNCTION BOX
JAN JANITOR
JT JOINT
KIT KITCHEN
L LENGTH
LAB LABORATORY
LAV LAVATORY
LB POUND
LTG LIGHTING
M METER
MAX MAXIMUM
MBL MARBLE
MC MEDICINE CABINET
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MM MILLIMETER
MTD MOUNTED
MTL METAL
MUL MULLION
N NORTH
(N) NEW
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OFF OFFICE
OH OPPOSITE HAND
OPP OPPOSITE
O/ OVER
P PAINT
PL PROPERTY LINE OR PLATE
PL PLANTER
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLWD PLYWOOD
POT PATH OF TRAVEL
PR PAIR
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RADIUS
RCPT RECEPTION
RD ROOF DRAIN
REF REFERENCE
REFR REFRIGERATOR
REINF REINFORCED
REQ'D REQUIRED
RM ROOM
RO ROUGH OPENING
RR RESTROOM
RWD REDWOOD
RWL RAIN WATER LEADER
S SOUTH
SAWPM SELF-ADHERING WATERPROOF MEMBRANE
SCD SEAT COVER DISPENSER
SCHED SCHEDULE
SD SOAP DISPENSER
SDST SELF DRILLING SELF TAPPING
SF SQUARE FEET, SQUARE FOOT
SIM SIMILAR
SMS SHEET METAL SCREW
SND SANITARY NAPKIN DISPENSER
SNR SANITARY NAPKIN RECEPTACLE
SQ SQUARE
SSC SOLID SURFACE COUNTERTOP
SS SERVICE SINK
SST STAINLESS STEEL
ST STONE
STD STANDARD
STL STEEL
STN STAIN
STOR STORAGE
STRUCT STRUCTURAL
SUPPL SUPPLEMENTAL
T TREAD
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TERM TERMINATION
THK THICK
TJ TOOLED JOINT
TO TOP OF
TPD TOILET PAPER DISPENSER
TV TELEVISION
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UR URINAL
V RESILIENT FLOOR
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
W WALL
W WEST
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WCHR WHEELCHAIR
WCT WAINSCOT
WCV WALL COVERING
WD WOOD
WH WATER HEATER
WP WATER PROOF
WR WATER RESISTANT
WT WEIGHT
WWF WELDED WIRE FABRIC
YD YARD
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
G002
LH ER ER
NA
ARCHITECTURAL
COVER SHEET
000000000012027E
NTS
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
V1
No. Date Description
SFM Permit No
25-S-2521
07/31/27
TYP.
20' - 0"
SOUTH CIRCLE DRIVE
E-1
E-2E-7
E-3
E-4
E-6
E-5
E-1
E-2E-7
E-3
E-4
E-6
E-5
PROPOSED STAGING AREA, V.I.F.
101101101101
101101 101101
101101101101
103103
103 103
TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
107107
R
ID
G E
R
ID
G E
R
ID
G E
RIDGE
SITE PLAN NOTES - GENERAL
DEMO ROOF NOTES
1. CONTRACTOR WILL MAINTAIN AN ALL-WEATHER APPROVED EMERGENCY
VEHICLE ACCESS ROADWAY WITH A MINIMUM DIMENSION OF 20' IN WIDTH
AND 13' - 6" IN VERTICAL CLEARANCE THROUGHOUT CONSTRUCTION
PERIOD CONFORMING TO CFC §503, §3310.1 & NFPA 241 AND
COORDINATED WITH CSFM AND LOCAL AHJ PRIOR TO COMMENCEMENT OF
ANY SITE AND ACCESS ALTERATION
2. ALL CONTRACTORS PERFORMING WORK ON THIS PROJECT SHALL
COMPLY WITH THE REQUIREMENTS OF CFC CH. 11, CH. 33 AND NFPA 241
FIRE-PREVENTION PROGRAM THROUGHOUT ALL PHASES OF
CONSTRUCTION
3. PROJECT EXEMPT FROM 11B-202.4 PATH OF TRAVEL REQUIREMENTS IN
ALTERATIONS, ADDITIONS AND STRUCTURAL REPAIRS THROUGH
EXEMPTION 7, REROOFING
4. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND
BUILDING CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION.
5. STAGING AREA SHOWN IS ILLUSTRATIVE ONLY, GENERAL CONTRACTOR
MUST VERIFY WITH OWNER FOR FINAL LOCATION. EXISTING SURFACE
STRIPING TO BE PROTECTED FOR CONSTRUCTION DURATION. AREA TO BE
PROTECTED AND SECURED WITH TEMPORARY CHAINLINK FENCE AND
GATE.
1. REMOVE AND DISCARD ALL EXISTING ROOFING SYSTEMS AS INDICATED,
DOWN TO THE STRUCTURAL DECK. INSPECT EXISTING ROOF DECK, REMOVE
AND REPLACE DAMAGED SUBSTRATE AS NECESSARY, 10% ASSUMED.
2. BUILDING SHALL REMAIN OCCUPIED AND OPERATIONAL AT ALL TIMES. ALL
ROOFTOP EQUIPMENT, DEVICES, ETC. MAY BE INTERMITTENTLY DISPLACED
FOR NEW WORK, BUT SHALL REMAIN OPERATIONAL AT ALL TIMES.
CONTRACTOR TO SUBMIT DETAILED WRITTEN DESCRIPTION OF PLANNED
DEMOLITION STAGES AND PHASED SEQUENCING IN ADVANCE OF THE WORK.
3. REMOVE (E) GUTTER AND DOWNSPOUT FOR REROOFING WORK.
4. REMOVE (E) METAL COPING / FASCIA, & FLASHING / COUNTERFLASHING.
5. REMOVE (E) ROOF EXHAUST MECHANICAL FANS AND CURB. REPLACE CURB
AND PREPARE WOOD DECK FOR NEW CURB INSTALLATION AND REROOFING
WORK. NOTIFY THE STATE IF ANY DISCREPANCIES BEFORE COMMENCING OF
WORK. SEE MECHANICAL SHEETS FOR ADDTIONAL INFORMATION.
6. INSPECT (E) ROOF DECK OPENING AT PENETRATIONS, REMOVE (E) RAISED
CURBS AS NECESSARY (10% ASSUMED) TO BE REPLACED WITH RAISED
CURBS TO ADDRESS INCREASED ISO RIGID INSULATION THICKNESS.
TEMPORARILY REMOVE UNIT / EQUIPMENT FOR REINSTALLATION AFTER NEW
RAISED CURB & GSM FLASHING IS INSTALLED.
7. REMOVE ALL UPSTANDING ROOF MATERIAL, PREPARE SURFACE TO RECEIVE
NEW SCOPE OF WORK. TEMPORARILY REMOVE ALL CONDUIT AND DEMOLISH
WOOD CONDUIT SUPPORTS.
8. REMOVE FLASHING AT MECHANICAL SCREEN SUPPORTS, AND PREPARE
SURFACE FOR NEW FLASHING.
DEMO ROOF - LEGEND
KEY NOTES
REMOVE (E) FLASHING
AT MECHICAL EQUIPMENT,
SEE MECHANICAL
DRAWINGS
REMOVE (E) FLASHING AT (E)
ROOF PENETRATIONS
REMOVE (E) FLASHING AT
ROOF EDGE
REMOVE EXISTING ROOFING.
PREPARE (E) DECKING FOR
ROOFING SYSTEM
REMOVE CONDUIT BLOCKING,
DISCONNECT CONDUIT, SEE
MECHANICAL DRAWINGS
TEMPORARILY REMOVE MECHANICAL
EQUIPMENT FOR NEW ROOF
INSTALLATION. SEE MECHANICAL.
REMOVE GUTTER AND
DOWNSPOUT
DEMOLISH (E) WALKPAD
(E) ROOF RIDGE AND VALLEY
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Reference North Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
G010
LH ER ER
NA
ILLUSTRATIVE SITE &
DEMO PLAN
000000000012027E
AS NOTED
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
V1
3/64" = 1'-0"1 CENTRAL SCHOOL - ROOF DEMO PLAN
# DESCRIPTION
101 REMOVE (E) ROOFING AND (E) RIGID INSULATION IN ITS ENTIRETY.
102 REMOVE AND REPLACE (E) GUTTER & DOWNSPOUTS. REPLACE WOOD
FASCIA IF DAMAGE TO BE FOUND DURING GUTTER REMOVAL (10%
ASSUMED).
103 REMOVE (E) METAL FASCIA AT ROOF EDGE.
104 REMOVE (E) WALKING PADS.
105 TEMPORARILY REMOVE (E) ACCESS LADDER.
106 TEMPORARILY REMOVE (E) MECHANICAL VENT / EQUIPMENT, CURB &
FLASHING ASSEMBLY SEE MECHANICAL DWGS.
107 REMOVE SKYLIGHT GLAZING AND FASTENERS. PREPRARE CURB FOR NEW
JOIST FRAMING AND ROOF COVERING.
No. Date Description
SFM Permit No
25-S-2521
07/31/27
07-28-25
(E) FIRE APPARATUS ACCESS ROAD
IMAGE 01
IMAGE 02
IMAGE 03
IMAGE 04
IMAGE 05
IMAGE 06
IMAGE 07
IMAGE 08
IMAGE 09
IMAGE 10
IMAGE 11
IMAGE 12KEY PLAN
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
G020
LH ER ER
NA
(E) SITE IMAGERY
000000000012027E
NTS
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
1 1/2" = 1'-0"1 REFERENCE PHOTOS
No. Date Description
SFM Permit No
25-S-2521
07/31/27
07-28-25
V1
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :2
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
A021
LH ER ER
NA
AS-BUILT
REFERENCE
DRAWINGS
000000000012027E
NTS
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
No. Date Description
FOR REFERENCE ONLY - NOT TO SCALE
SFM Permit No
25-S-2521
07/31/27
07-28-25
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
A022
LH ER ER
NA
AS-BUILT
REFERENCE
DRAWINGS
000000000012027E
NTS
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
No. Date Description
FOR REFERENCE ONLY - NOT TO SCALE
SFM Permit No
25-S-2521
07/31/27
07-28-25
E-1
E-2E-7
E-3
E-4
E-6
E-5
A531
RIDGE
R
ID
G E
R
ID
G E
R
ID
G E
A531
A531
113' - 8"
115' - 2"
167' - 0" 129' - 8"
113' - 0"
113' - 8"
A531
RIDGE
A531
A531
A531
A531
A531
A531
A531
136' - 8"
14' - 0"
12' - 7"
MAX
36' - 0"
TYP
TYP
TYP
TYP
TYP
TYP
TYP
204204
204204
2062069
A531
TYP
TYP
TYP
A531
TYP
A531
TYP
TYP
TYP
TYP
A531
TYP
A531
TYP
A531
TYP
A531
T Y
P
T Y
P
T Y
P
T Y
P
T Y
P
T Y
P
301 301
A531
A531
A531
TYP
TYP
TYP
A531
A531
A531
A531
A531
TYP
SHEET LEGEND - ROOF
(E) MECHANICAL
EQUIPMENT, REPLACE (E)
FLASHING
FLASHING AT (E) ROOF
PENETRATIONS
SLOPE & DIRECTION 1/2" / 12" MIN.
RIDGE
FLASHING AT ROOF EDGE
1/X" = 1'-0"
ADHERED PVC ROOFING WITH
SUPPLEMENTAL MECHANICAL
ATTACHMENT
CONDUIT AND CONDUIT BLOCK
SUPPORT (SEE MECHANICAL)
MECHANICAL EQUIPMENT
DISCONNECT AND UNINSTALL.
RELOCATE. PROVIDE FLASHING
AT CURBS. REPAIR PLATFORM
AND CURBS AS REQUIRED.
GUTTER AND DOWNSPOUT
A531
A531
A531
FALL PROTECTION ANCHOR
POINT
A531
A531
A531
A531
GENERAL NOTES
1. DASHED LINES INDICATE WALL BELOW, CONTRACTOR TO VERIFY IN FIELD.
2. ALL ROOF DECK HEIGHTS ARE MEASURED FROM THE MAIN T.O. FINISHED
FLOOR AT DATUM +0'-0" U.O.N.
3. EXISTING ROOF PITCH (1/2" / 1'-0" MIN.) TO REMAIN AND TO BE VERIFIED IN
FIELD. CONFIRM COMPLIANCE WITH MANUFACTURE'S WARRANTY.
4. INSTALL NEW BOX GUTTERS ALONG LOWER ROOF EDGE OF BUILDINGS E1-E7
AND DOWNSPOUTS LOCATIONS INDICATED ON DRAWINGS.
5. PROVIDE NEW RIGID INSULATION AND TAPERED POLYISOCYANURATE RIGID
INSULATION FOR IMPROVED ENERGY EFFICIENCY. MINIMUM R-VALUE
REQUIRED IS R-23.
6. PROVIDE NEW 1/4" FIBERGLASS COATED GYPSUM BOARD (DENSDECK OR
EQUAL) ROOF BOARD.
7. PROVIDE NEW PVC SINGLE-PLY ROOF MEMBRANE WHITE COLOR.
8. PROVIDE CRICKETS AT PENETRATIONS FOR POSITIVE DRAINAGE.
9. METAL FLASHING AND METAL TRIM TO MATCH EXISTING TRIM OR FLASHING.
KEYNOTES
/12 A531
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:0 :3
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
A131
LH ER ER
NA
ROOF PLAN
000000000012027E
AS NOTED
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
V1
1/16" = 1'-0"1 ROOF PLAN
0' 8' 16' 32' 64'
# DESCRIPTION
201 NEW ACCESS LADDER.
202 (E) MECHANICAL EQUIPMENT TO BE REINSTALLED AND CONNECTED TO (E)
DUCTWORK WITH NEW RAISED CURB (AS REQUIRED) & FLASHING, SEE
MECHANICAL SHEETS. MAINTAIN A MININUM 3 FEET CLEARANCE FOR
MAINTENANCE. SEE DTL 6/A531 FOR FLASHING AND MECH SHEETS.
203 NEW METAL BOX GUTTER & DOWNSPOUT SYSTEM.
204 NEW GSM METAL FASCIA AT ROOF EDGE.
206 FRAME OVER EXSTING SKYLIGHT SYSTEM. SEE DTL.
301 FALL PROTECTION ZONE, SERVICEABLE EQUIPMENT & DEVICES WITHIN FALL
PROTECTION ZONE SHALL BE SUPPLIED WITH FALL PROTECTION RESTRAINT
SYSTEM.
No. Date Description
SFM Permit No
25-S-2521
07/31/27
FASTEN COVER BOARD
RIGID INSULATION TO
SUBSTRATE PER MFR.
RECOMMENDATIONS AND
DTL 6/A531
SINGLE-PLY MEMBRANE
FULLY ADHERED TO COVER
BOARD
ADHESIVE
1/4" GLASS MAT-FACED
GYP COVER BOARD
TAPERED RIGID INSULATION
SLOPE PER ROOF PLAN
3" BASE LAYER RIGID
INSULATION (OMIT AT
WALKWAYS AND SKYLIGHT
REPLACEMENT)
VAPOR BARRIER
SUBSTRATE
CALCULATION (SEE NOTE)
SPACING BY UPLIFT
FASTENERS 4" OC
STAGGERED
FLASHING STRIP, HOT-AIR
WELDED
ALUMINUM TAPE OVER JOINT
COATED METAL
1/4" GAP
2"
4"
4" M
IN
4" OC
1/2" DRIP TYP
FLASHING STRIP,
CONT WELDED
COVERBOARD & INSULATION
FASTENER
SINGLE-PLY
ASSEMBLY
SUPPLEMENTAL
ATTACHMENT @ 12" OC MAX
AT SLOPE CHANGES
GREATER THAN 1:12
SUBSTRATE
5" MIN
(E) MECHANICAL UNIT, SEE
MECH DWGS FOR BASE RAIL
& ADDITIONAL SECUREMENT
TO CURB
FASTENER W/ NEOPRENE
WASHER 12" OC, MAX
COATED GSM COUNTER
FLASHING W/ DRIP
SET IN CONT SEALANT
SINGLE-PLY MEMBRANE
FLASHING
SUPPLEMENTAL
FASTENER
CONT WELD SINGLE-PLY
FLASHING TO SINGLE-PLY
MEMBRANE
SINGLE-PLY
ASSEMBLY
2" MIN
SUBSTRATE
5" MIN
A531
A531
A
CORNER DEFINITON
DIAGRAM NTS
BLDG HEIGHT
LESS 60'
BLDG HEIGHT
60' OR HIGHER
2X
SUPPLEMENTAL
ATTACHMENT AT PERIMETER
SUPPLEMENTAL
ATTACHMENT AT ALL
PENETRATION PER
MIN 4 PER
PENETRATION
FULLY ADHERED SINGLE-PLY
TO COVER BOARD
COVER BOARD & INSULATION
ATTACHMENT PER MFG
SUPPLEMENTAL
ATTACHMENT AT ALL CURBS
12" MAX
M A
X
3" LAP MIN
X
B
PLAN
NOTE:
THE SINGLE-PLY ASSEMBLY MUST HAVE BEEN SUCCESSFULLY TESTED BY
A QUALIFIED TESTING AGENCY FOLLOWING ANSI/FM 4474 TO RESIST THE
DESIGN UPLIFT PRESSURES CALCULATED PER ASCE 7 BY A LICENSED
ENGINEER REGISTERED IN THE STATE OF CALIFORNIA. ASSEMBLY UPLIFT
PRESSURES SHALL BE NOT ASSUMED TO BE LESS THAN 60 LBS/SQ FT.
(4) 3/4" DIA. x 3.75" MIN. EFFECTIVE
EMBEDMENT HILTI KB TZ 2 SS 316
PER ICC ESR 4266
3/4" DIA. S.S. U-BAR
3" DIA. DOUBLE EXTRA STRONG
GALV. PIPE, PAINT YELLOW
(4) 3/4" DIA. BOLTS MIN.
7/8" x 14" SQR. HIGH STRENGTH
GALV. STEEL BASE PLATE
(E) WOOD SUBSTRATE
7/8" x 14" SQR HIGH STRENGTH GALV.
STEEL BASE PLATE
1' - 2"
3" DIA. DOUBLE EXTRA STRONG PIPE
TYP.
3/8
INSULATION SECURED AS
SPECIFIED
PVC MEMBER, ADHERED
HOT-AIR WELD
MEMBRANE ATTACHMENT
BAR FASTENED 12"O.C. MAX.
SPACING
PVC FLASHING MEMBRANE
ADHERED TO ACCEPTABLE
SURFACE
COVER BOARD
STORM COLLAR
A531
(E) WOOD STRUCTURE
5 X 5 BOX GUTTER SYSTEM WITH
GUTTER SPACER & COVER.
COORDINATE INSTALLATION
HEIGHT WITH GUTTER AT DTL.
HOT-AIR WELDED CONT
MEMBRANE, FLASHING
(E) WOOD DECK 2X8
T&G
CONT 22 GA GALV. SHEET METAL
EDGE FLASHING OVER ROOF
MEMBRANE W/ FASTENERS AS
RECOMMENDED BY ROOFING
SYSYTEM MFR. ( @ 12" O.C. MAX
W/CONTINUOUS CONCEALED CLEAT)
0' - 3"
0' - 5"
M
IN
/2
0' - 5"
WOOD BLOCKING
SINGLE-PLY ASSEMBLY
M
IN
(E) 2x3 FASCIA , PRIME
AND PAINT TO MATCH
(E), REPLACE FASCIA
AND FASTENERS IN
KIND WHERE DAMAGED
DOWNSPOUT TO
COLUMN IN SAME
LOCATION AS (E), SEE
DETAIL 7/A531
A531
SINGLE-PLY ROOF
ASSEMBLY
UNIVERSAL COLLAR
APPROVED FASTENER
AND DISC PER MFR., 1"
MIN. EMBEDMENT
M
IN
HOT-AIR WELD
COUPLING FOR
EXTENSION W/ HOSE
CLAMP SEE MECHANICAL
BASE FLASHING PER MFR.
HOT-AIR WELD
NEW EXTENSION AS
REQUIRED
ALUMINUM TAPE AS
REQ'D @ (E) PIPE
ELASTIC SEALANT W/ S.S.
HOSE CLAMP
(E) PLYWOOD TO REMAIN
5/8" DEEP SEALANT
NOTE: SEE MECHANICAL DETAILS FOR ADDITIONAL
PIPE INFORMATION
4" X 4" 22 GA
DOWNSPOUT
WHERE DRAIN NOT
PRESENT, SPLASH BLOCK
ON GRADE / ROOF, SET IN
PLACE TO PROVIDE POSITIVE
DRAINAGE AWAY FROM
BUILDING
OPEN AT BOTTOM OF
DOWNSPOUT WHERE NO
DRAIN (E). ROUTE TO DRAIN
WHERE PRESENT.
ATTACH 16 GA GALVANIZED
DOWNSPOUT STRAP
BRACKET AROUND ROUND
STEEL COLUMN. ATTACH AT
TOP AND BOTTOM.
(2) 3/16" GALV. SMS EA SIDE
OF DOWNSPOUT
(E) STEEL COLUMN
M
IN
SUPPLEMENTAL
ATTACHMENT
CONT WELD
SINGLE-PLY MEMBRANE
FLASHING
GROMMETTED FASTENER
@ 12" OC, FASTENER TO BE
APPROPRIATE TYPE FOR
WALL SUBSTRATE
SEALANT
FASTENED @ 12" OC,
FASTENER TO BE
APPROPRIATE TYPE FOR
WALL SUBSTRATE
5" MIN
COVER BOARD &
INSULATION
FASTENER
SINGLE-PLY ASSEMBLY
A531
A531
HOT-AIR WELDED
CONTINUOUS MEMBRANE
FLASHING
(E) WALL WITH
CEMENT PLASTER
SYSTEM
WOOD BLOCKING
(E) 2X3
SINGLE-PLY
ASSEMBLY
A531
CONT 22 GA GALV. SHEET
METAL EDGE FLASHING
OVER ROOF MEMBRANE
W/ FASTENERS AS
RECOMMENDED BY
ROOFING SYSTEM MFR.
( @ 12" O.C. MAX
W/CONTINUOUS
CONCEALED CLEAT)
M
IN
0' - 5"
SCREW W/ NEOPRENE
WASHER
4' - 0"
2x4 FRAME @ 16" SPACING
FASTENED TO (E) SKYLIGHT
FRAME (E) 4x12 ROOF STRUCTURE, TYP
(E) 2x8 T&G WOOD DECK, TYP
5/8" PLYWOOD
COVERBOARD
TAPERED RIGID INSULATION
CONT 22 GA GALV. SHEET METAL EDGE FLASHING OVER
ROOF MEMBRANE W/ FASTENERS AS RECOMMENDED BY
ROOFING SYSTEM MFR. TYP.
M
IN
T
Y P
HOT AIR WELDED CONTINUOUS MEMBRANE FLASHING, TYP.
SINGLE PLY MEMBRANE
TYP.
0 - 5"
COVER BOARD
(E) SKYLIGHT WOOD FRAME
NOTE: REMOVE (E) LADDER FOR
ROOF INSTALLATION, RE-INSTALL
LADDER WITH MODIFICATIONS AS
NECESSARY TO MEET DETAIL
REQUIREMENTS OR REPLACE
WITH LADDER MEETING
REQUIREMENTS.
LADDERS SHALL BE CONSTRUCTED IN
ACCORDANCE WITH THE FOLLOWING:
(1) SIDE RAILINGS SHALL EXTEND NOT LESS
THAN 42 INCHES ABOVE THE ROOF.
(2) LANDING PLATFORM REQUIRED WHEN
HEIGHT EXCEEDS 20 FEET. LANDINGS 24"
MIN. IN WIDTH AND 30" MIN IN LENGTH.
(3) WIDTH SHALL BE NOT LESS THAN 16
INCHES ON CENTER.
(4) TOE SPACE SHALL BE NOT LESS THAN 7
INCHES RUNGS SPACING SHALL NOT
EXCEED 12 INCHES ON CENTER, AND EACH
RUNG SHALL BE CAPABLE OF SUPPORTING
A 300 POUND LOAD.
1' - 4" MIN.
5/8"X2" METAL STRINGERS
3/4" X 1'-4" MIN. LONG
METAL RUNG
BENT 9" X3"X1/4" PLATE
STRAPS-WELD TO
STRINGER, ATTACH W/ 1/2"
DIA BOLTS, TYP
B- PLAN
A- ELEVATION C- SECTION
STRINGER
TYP
RUNG
PLATE STRAPS
D- WELD AT
STRINGER
M
IN
C
B
M A
X
1' - 4" MIN.
ROOF
M
IN
ROOF
NOTE: WHERE RUNG MODIFICATIONS REQUIRED
2' - 0" MAX
1' - 6" MIN.
MIN.
7"
M A
X
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f
G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
/2
/2
:5 :2
P
M C
U s e rs \E d R e y e s\ D e sk to p
\1
E A
R C
R e ro o f.
rv t
A531
LH ER ER
NA
ROOFING DETAILS
000000000012027E
AS NOTED
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
25-S-2521
3" = 1'-0"1 SINGLE PLY ASSEMBLY
6" = 1'-0"2 FLASHING AT JOINTS
3" = 1'-0"4 PEAK / RIDGE
3" = 1'-0"6 CURB FLASHING UNIT
1/4" = 1'-0"10 SINGLE PLY ASSEMBLY ATTACHEMENT
1 1/2" = 1'-0"8 ANCHOR POINTS
3" = 1'-0"3 ROOF GUTTER & FASCIA
3" = 1'-0"5 VENT STACK FLASHING
3" = 1'-0"7 DOWNSPOUT3" = 1'-0"9 COUNTERFLASH TERM.
No. Date Description
3" = 1'-0"11 TYP. RAKE FLASHING
1 1/2" = 1'-0"12 SKYLIGHT REPLACEMENT FRAMING
3/4" = 1'-0"13 LADDER
07/31/27
07-28-25
AD
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
L
EG
EN
D S
AN
D
N O
TE
S.
dw g
P lo t D at e:
J un
0,
- 1 2:
pm
Pl ot te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
LEGENDS AND
NOTES
AS NOTED
M001
M15_LG02
PLUMBING SYMBOLS & PIPE LEGEND
M15_LG01
DUCT AND ACCESSORIES LEGEND
GENERAL NOTES
ABBREVIATIONS
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
O
VE
R
AL
L
R O
O F
PL
AN
.d w g P lo t D at e:
J un
0,
- 1
2:
te d by : N
G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
OVERALL
ROOF PLAN
AS NOTED
M100
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
OVERALL ROOF PLAN - MECHANICAL WORK1
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E5
AS NOTED
M141
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK1
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E4
AS NOTED
M142
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK22
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E6
AS NOTED
M143
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK22
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E3
AS NOTED
M144
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK22
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E7
AS NOTED
M145
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK22
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
R
O O
F
PL
AN
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
ROOF PLAN
BUILDING E1 & E2
AS NOTED
M146
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
ROOF PLAN - MECHANICAL WORK22
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
1 SHEET NOTES1
KEYNOTES
6/30/2025
F ile
: X :\P ro je ct s\ xx xx \0
7E \D
W G
\P
LT
\M
M
EC
H
AN
IC
AL
D
ET
AI
LS
.d w g
P lo t D at e:
J un
0,
- 1 2:
te d by
: N G as pa rr
V1
707 Third Street, Suite 4-105
Architecture & Engineering Sections
Project Management & Development Branch Real Estate Services Division
State of California
West Sacramento, California 95605
Department of General Services
C op yr ig ht
5, C al ifo rn ia
D ep ar tm en t o f G en er al
S er vi ce s
- R ea l E st at e Se rv ic es D iv is io n
N.GASPARRON.GASPARROM.MILES
MECHANICAL
DETAILS
AS NOTED
M600
PORTERVILLE, CA 93258
DEVELOPMENTAL SERVICES
26501 AVENUE 140
DDS PORTERVILLE
ROOF REPLACEMENT -
TULARE COUNTY
000000000012027E
02-11#### 25-S-2521-C
CENTRAL SCHOOL
M15_FN01
ROOF EXHAUST FAN SUPPORT
M15_DU02
DUCT THRU ROOF DETAIL
M15_AC01
HVAC UNIT SUPPORT
No. M29425
MA
TT
HEW TODD MI LES
RE
G
I S
TE
RED PROFESS IONAL ENGINEER
MECHA NICA LSTATE OF CAL I FORNIA
4 PIPE SUPPORT ON ROOF
PIPE THROUGH ROOF DETAIL
M15_DP01
M15-FH01
FLUE THROUGH ROOF6 6/30/2025
NEW ROOFING
REF. ARCH. DWGS.
20 GAUGE GALVANIZED
STEEL ROOF JACK WITH
EPR RUBBER GROMMET
PIPE BOOT.
(E) CONDUIT
ELASTIC SEALANT
STAINLESS STEEL
HOSE CLAMP.
6# SOFT LEAD
CONE SHAPED
COUNTER FLASHING
NON HARDENING
RTE SILICON RUBBER
CAULKING
NON HARDENING
WET PATCH BLACK
ROOF MASTIC
PROVIDE NEW B-LINE DURA-BLOK
OR EQUAL.
(E) CONDUIT
PROVIDE (N) CONDUIT STRAP
NEW ROOFING
R
ELECTRICAL
E E
NI
GNE
LANOISSEFORP
DERET
SI
G
E R
C A L I F O RN I A
S T A T E
O F
CONSULTING ENGINEERS
ALAMEDA | AUBURN | LOS ANGELES
https://www.engent.com
NEOSHO | SAN DIEGO | SANTA BARBARA
Issue
Project
Supervisor Designed Drawn
DSA App No.
Sheet Title
Project Number
Sheet Scale
Sheet Number
A x
C o p y ri g h t
C a lif o rn ia D e p a rt m e n t o f G e n e ra l S e rv ic e s
R e a l E s ta te S e rv ic e s D iv is io n
BCDEFGHIJKLMNO
ABCDEFGHIJKLMNO
SFM Permit No.
RELATIVE BORDER SCALE IN INCHES
0 1 2 3
DDS PORTERVILLE
ROOF REPLACEMENT -
CENTRAL SCHOOL
26501 AVENUE 140
PORTERVILLE, CA 93258
TULARE COUNTY
DEVELOPMENTAL SERVICES
02-11####
000000000012027E
#E015491 Exp. 06/30/27
SCOTT WHEELER
/1 /2 :0 :1 A M
C U se rs \s h a n e .f ra n k e \D o c u m e n ts \P D C C e n tr a l S c h o o l R o o f
R e p la c e m e n t_ E L E C R sh a n e .f ra n k e .r vt
E001
SW ShF ShF
GENERAL NOTES,
SYMBOLS AND
DETAILS
ELECTRICAL SHEET INDEX
SHEET NO. SHEET NAME
E001 GENERAL NOTES, SYMBOLS AND DETAILS
E201 ELECTRICAL ROOF PLAN - CENTRAL SCHOOL
E202 ELECTRICAL ROOF PLAN - CENTRAL SCHOOL
EXISTING TO REMAIN
EXISTING TO BE REMOVED (R) OR RELOCATED (RR)
NEW CONSTRUCTION
FUTURE CONSTRUCTION
LINESTYLES
POWER DISTRIBUTION
SWITCHGEAR, SWITCHBOARD, DISTRIBUTION BOARD, SUBSTATION OR MOTOR CONTROL
CENTER, FLOOR MOUNTED ON CONCRETE HOUSEKEEPING PAD WHERE INDICATED ON
DRAWINGS. DOUBLE LINE INDICATES FRONT FACE OF GEAR.
DISTRIBUTION BOARD, SURFACE MOUNTED ON WALL.
PANELBOARD, 277/480V, SURFACE MOUNTED ON WALL.
PANELBOARD, 277/480V, FLUSH MOUNTED IN WALL.
PANELBOARD, 120/208V, SURFACE MOUNTED ON WALL.
PANELBOARD, 120/208V, FLUSH MOUNTED IN WALL.
DRY-TYPE STEP-DOWN TRANSFORMER, FLOOR MOUNTED 480-120/208V 3Ø, UON. DOUBLE
LINE INDICATES FRONT FACE OF TRANSFORMER.
ELECTRIC MOTOR, NIEC. MAKE POWER CONNECTIONS ONLY AS NOTED ON PLANS.
EXHAUST FAN MOTOR, SINGLE PHASE, NIEC. MAKE POWER CONNECTIONS TO INCLUDE
JUNCTION BOX MOUNTED, FRACTIONAL HORSEPOWER MANUAL MOTOR STARTER WITH
INTEGRAL DISCONNECT ADJACENT TO FAN WITH 2 #12 CONDUCTORS PLUS GROUND IN
1/2" FLEXIBLE CONDUIT BETWEEN STARTER AND MOTOR.
INDOOR FAN POWERED VAV BOX MOTOR, SINGLE PHASE, NIEC. MAKE POWER
CONNECTIONS TO INCLUDE JUNCTION BOX MOUNTED, FRACTIONAL HORSEPOWER
MANUAL MOTOR STARTER WITH INTEGRAL DISCONNECT ADJACENT TO VAV BOX WITH 2 #
12 CONDUCTORS PLUS GROUND IN 1/2" FLEXIBLE CONDUIT BETWEEN STARTER AND
MOTOR.
MOTOR OPERATED FIRE/SMOKE DAMPER 'FSD', NIEC. SYMBOL DENOTES INTERFACE FOR
POWER CONNECTIONS WITH LOCAL DISCONNECT MEANS. ADJACENT NUMBER INDICATES
QUANTITY OF ACTUATORS PER FSD, EACH REQUIRING A POWER CONNECTION, IF MORE
THAN 1. FOR FIRE ALARM REQUIREMENTS AT FSD, REFER TO FIRE ALARM SYMBOLS.
COMBINATION EXHAUST FAN AND DOWNLIGHT, CEILING MOUNTED. FAN AND LIGHT SHALL
BE CONTROLLED SEPARATELY.
PULLBOX OR HANDHOLE, SIZE AND TYPE AS NOTED ON PLANS.
SAFETY DISCONNECT SWITCH, 3 POLE, UON. ADJACENT NUMBER INDICATES FUSE SIZE
WHEN APPLICABLE. LABELING CONVENTION AS FOLLOWS:
A: 30A, NON-FUSED AF: 30A, FUSED
B: 60A, NON-FUSED BF: 60A, FUSED
C: 100A, NON-FUSED CF: 100A, FUSED
D: 200A, NON-FUSED DF: 200A, FUSED
E: 400A, NON-FUSED EF: 400A, FUSED
F: 600A, NON-FUSED FF: 600A, FUSED
G: 800A, NON-FUSED GF: 800A, FUSED
MAGNETIC MOTOR STARTER WITH INTEGRAL OVERCURRENT PROTECTION. ADJACENT
NUMBER INDICATES NEMA SIZE OF STARTER. "HANDLE" DENOTES INTEGRAL DISCONNECT.
VARIABLE FREQUENCY DRIVE FURNISHED UNDER ANOTHER DIVISION. INSTALL VFD AND
PROVIDE POWER SERVICE CONNECTION UNDER THIS DIVISION. "HANDLE" DENOTES
INTEGRAL DISCONNECT.
ELECTRONICALLY COMMUTATED MOTOR CONTROLLER FURNISHED UNDER ANOTHER
DIVISION. INSTALL ECM AND PROVIDE POWER SERVICE CONNECTION UNDER THIS
DIVISION. "HANDLE" DENOTES INTEGRAL DISCONNECT.
PACKAGE MOTOR CONTROLLER OR STARTER FURNISHED AND INSTALLED UNDER
ANOTHER DIVISION WITH EQUIPMENT CONTROLLED. PROVIDE SINGLE-POINT POWER
SERVICE CONNECTION UNDER THIS DIVISION AS NOTED ON PLANS.
DRIVEN GROUND ROD.
DRIVEN GROUND ROD IN GROUND WELL WITH COVER.
ELECTRICAL VEHICLE CHARGING STATION, WALL MOUNTED.
ELECTRICAL VEHICLE CHARGING STATION, PEDESTAL MOUNTED.
CABLE TO BUS TERMINATION LUGS.
BOLTED PRESSURE OR HIGH PRESSURE CONTACT OR FUSED SWITCHES.
GROUP MOUNTED MOLDED CASE CIRCUIT BREAKER.
INDIVIDUALLY FIXED MOUNTED INSULATED-CASE OR POWER CIRCUIT BREAKER.
INDIVIDUALLY DRAW-OUT MOUNTED INSULATED-CASE OR POWER CIRCUIT BREAKER.
MEDIUM-VOLTAGE, INDIVIDUALLY DRAW-OUT MOUNTED VACUUM CIRCUIT BREAKER.
MEDIUM-VOLTAGE LOAD INTERRUPTER SWITCH, FUSED TYPE.
MEDIUM-VOLTAGE LOAD INTERRUPTER SWITCH, NON-FUSED TYPE.
GROUND FAULT RELAY INTEGRAL WITH CIRCUIT BREAKER.
ELECTRICALLY OPERATED CIRCUIT BREAKER, INTEGRAL.
SHUNT-TRIP INTEGRAL WITH OVERCURRENT PROTECTION DEVICES.
KIRK-KEY INTERLOCK INTEGRAL WITH OVERCURRENT PROTECTION DEVICES. ADJACENT
NUMBER CORRESPONDS WITH DEVICE INTERLOCK.
PRIVATE METER, MOUNTED INTEGRAL WITH OVERCURRENT PROTECTION OR SEPARATE
WITHIN SWITCHGEAR.
UTILITY METER, MOUNTED IN UTILITY METER SECTION OF SWITCHGEAR OR
SWITCHBOARDS.
PRIVATE METER, MOUNTED IN SEPARATE ENCLOSURE FROM SWITCHGEAR OR
SWITCHBOARDS.
GROUND FAULT RELAY WITH SHUNT TRIP.
GROUND FAULT ALARM, NO SHUNT TRIP.
TRANSFORMER.
CONNECTION TO GROUND.
GFA
GFR
K
ST
EO
M
G
M
WIRING DEVICES
JUNCTION BOX, WALL MOUNTED, +18" UON.
JUNCTION BOX, MOUNTED IN FLUSH FLOOR BOX.
JUNCTION BOX, MOUNTED FLUSH IN CEILING.
JUNCTION BOX, SURFACE OR PENDANT MOUNTED TO BOTTOM OF STRUCTURE IN
ACCESSIBLE CEILING SPACE OR EXPOSED IN OPEN CEILING AREAS.
JUNCTION BOX, MOUNTED ON CONDUIT STANCHION FLOOR PENETRATION, +12" UON.
SINGLE-PLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON. LETTERING
ADJACENT TO THE DEVICE ON THE PLANS INDICATE THE FOLLOWING FOR THOSE
RECEPTACLES.
A: ARC FAULT CURRENT INTERRUPTER (AFCI)
G: GROUND FAULT CURRENT INTERRUPTER (GFCI)
IG: ISOLATED GROUND
TR: TAMPER RESISTANT
U: INTEGRAL USB PORTS
WP: WEATHER-RESISTANT, GROUND FAULT CURRENT INTERRUPTER (GFCI) WITH
WEATHERPROOF "IN USE" COVER
DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED, +18" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, WALL MOUNTED OVER COUNTER, 6"
ABOVE BACK SPLASH UON, BUT NO HIGHER THAN ADA REQUIREMENTS.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, SPLIT-WIRED, WALL MOUNTED, +18" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, ON BACK-UP POWER SYSTEM, WALL
MOUNTED, +18" UON.
DUPLEX, OR DOUBLE DUPLEX, CONVENIENCE RECEPTACLE DEVICE, CONTROLLED PER
T24, WALL MOUNTED, +18" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, HORIZONTALLY WALL MOUNTED, +18"
UON.
SPECIALTY OUTLET DEVICE, NEMA CONFIGURATION TYPE AS NOTED ON PLANS, WALL
MOUNTED, +18" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FLUSH FLOOR BOX.
DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FLUSH FLOOR BOX.
COMBINATION POWER/TELECOMMUNICATION DEVICE, MOUNTED IN FLUSH FLOOR BOX.
TYPE AS NOTED ON PLANS OR IN SPECIFICATIONS.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FIRE-RATED POKE-THRU
FLOOR FITTING.
DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED IN FIRE-RATED POKE-
THRU FLOOR FITTING.
COMBINATION POWER/TELECOMMUNICATION DEVICE, MOUNTED IN FIRE-RATED POKE-
THRU FLOOR FITTING. TYPE AS NOTED ON PLANS OR IN SPECIFICATIONS.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED FLUSH IN CEILING.
DOUBLE DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED FLUSH IN CEILING.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, MOUNTED ON CONDUIT STANCHION
FLOOR PENETRATION, +12" UON.
DUPLEX CONVENIENCE RECEPTACLE DEVICE, CORD OR REEL HUNG FROM STRUCTURE
ABOVE. TYPE AS NOTED ON PLANS.
NUMBERED NOTE, APPLIES TO ALL DRAWINGS.
NUMBERED SHEET NOTE, APPLIES TO DRAWING CONTAINING NOTES ONLY.
OVERCURRENT PROTECTIVE DEVICE NUMBER IDENTIFICATION TAG. REFERS TO
LOCATION OF PROTECTIVE OR CONTROL DEVICE WITHIN SWITCHBOARDS,
DISTRIBUTION BOARDS, MOTOR CONTROL CENTERS, ETC.
EQUIPMENT IDENTIFICATION TAG: ITEM FURNISHED AND INSTALLED UNDER
ANOTHER DIVISION AND WIRED UNDER THIS DIVISION.
FEEDER TAG. REFER TO FEEDER SCHEDULE.
DETAIL REFERENCE:
DETAIL DESIGNATION
SHEET NUMBER
EQ
E-801
CONVENTIONS
RACEWAYS
CONDUIT RUN EXPOSED ON WALL OR CEILING.
CONDUIT RUN CONCEALED IN SLAB, UNDER SLAB OR UNDERGROUND.
CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING.
CONDUIT HOMERUN, CONTINUOUS RUN TO PANEL OR EQUIPMENT CABINET.
HOMERUN CAN OCCUR ON ANY OF THE ABOVE ROUTING CONDITIONS.
CONDUIT TURNED UP, CAN OCCUR ON ANY OF THE ABOVE ROUTING
CONDITIONS.
CONDUIT TURNED DOWN, CAN OCCUR ON ANY OF THE ABOVE ROUTING
CONDITIONS.
CONDUIT CAPPED OR STUBBED WITH INSULATED BUSHINGS, CAN OCCUR ON
ANY OF THE ABOVE ROUTING CONDITIONS.
CONDUIT SLEEVE, WITH INSULATING BUSHINGS.
FLEXIBLE METALLIC CONDUIT, EQUIPMENT CONNECTION.
CROSSMARKS ON BRANCH CIRCUIT CONDUIT RUNS INDICATE THE QUANTITY OF
CONDUCTORS AS FOLLOWS (GROUND CONDUCTORS ARE NOT NOTED, BUT
SHOULD BE INCLUDED IN EVERY CONDUIT WITH POWER CONDUCTORS):
1. NO CROSSMARKS INDICATES TWO #12 AWG CONDUCTORS, UON.
2. THREE TO SIX CROSSMARKS INDICATES THE QUANTITY OF #12 AWG
CONDUCTORS, UON.
3. SEVEN OR MORE CROSSMARKS INDICATES THE QUANTITY OF #10
AWG CONDUCTORS, UON.
SURFACE RACEWAY; TYPE, DEVICE SPACING AND MOUNTING AS NOTED ON
PLANS.
CABLE TRAYS; SIZE, TYPE, ANDMOUNTING AS NOTED ON PLANS.
V
F
A AF
1 1
VFD
VFD
ECM
ECM
D
J
J
J
J
J
M
P
SYMBOLS LIST GENERAL NOTES
SCALE:NTS
ROOF PENETRATION
SCALE:NTS
ROOF SUPPORT
1. ELECTRICAL SCOPE SHALL COMPLY WITH THE LATEST ADOPTED
EDITIONS OF THE CALIFORNIA ELECTRIC CODE (CEC), CALIFORNIA
BUILDING CODE (CBC), CALIFORNIA FIRE CODE (CFC), CALIFORNIA
MECHANICAL CODE (CMC), NATIONAL FIRE PROTECTION ASSOCIATION
(NFPA 72) AND THE CALIFORNIA ENERGY CODE.
2. THE CONTRACTOR SHALL VISIT THE JOBSITE AND VERIFY ALL EXISTING
CONDITIONS PRIOR TO BIDDING THE PROJECT AND SHALL INCLUDE IN
THEIR BID THE NECESSARY COSTS TO CONSTRUCT THIS PROJECT IN
ACCORDANCE WITH THE ELECTRICAL DRAWINGS, SPECIFICATIONS,
AND ALL APPLICABLE CODES.
3. DRAWINGS INDICATE GENERAL ARRANGEMENT OF ELECTRICAL
SYSTEMS AND WORK. FOLLOW THE DRAWINGS IN LAYING OUT WORK
AND VERIFY EXACT LOCATIONS WITH ARCHITECTURAL FLOOR PLAN
AND RCP DRAWINGS. ALSO, CHECK DRAWINGS OF OTHER TRADES TO
VERIFY LOCATIONS OF EQUIPMENT REQUIRING ELECTRICAL
CONNECTIONS AND COORDINATE SPACE CONDITIONS WITH THEIR
INSTALLATION. FINAL LOCATIONS SHALL BE ADJUSTED TO MEET FIELD
CONDITIONS.
4. NOT EVERY ELECTRICAL RACEWAY, BOX, CONDUCTOR, ETC., FOR A
COMPLETE ELECTRICAL INSTALLATION IS SHOWN ON THESE
DRAWINGS. THIS IS DONE FOR CLARITY PURPOSES AND EASE OF
INTERPRETING DRAWINGS. PROVIDE ALL ADDITIONAL ITEMS
REQUIRED TO MAKE THE ELECTRICAL SYSTEMS COMPLETE AND
OPERATIONAL.
5. WORK PERFORMED UNDER THIS CONTRACT SHALL CONFORM TO
THESE DRAWINGS AND SHALL ALSO COMPLY WITH THE ELECTRICAL
SPECIFICATIONS. IN THE EVENT THAT THERE IS A DISCREPANCY
BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE MORE
STRINGENT OF THE REQUIREMENTS SHALL TAKE PRECEDENT.
6. CONTRACTOR SHALL REMOVE ALL LEFTOVER CONDUIT, WIRE, SCRAPS,
ETC. AND LEAVE PREMISES CLEAN AND FREE OF TRASH AND DEBRIS
RESULTING FROM THEIR WORK.
7. THE EXISTING INSTALLATION SHOWN ON THESE DRAWINGS WAS
DEVELOPED FROM VARIOUS SOURCES AND NOT ALL CONDITIONS MAY
SHOWN. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS
PRIOR TO CONSTRUCTION.
8. RECONNECT EXISTING TO REMAIN DEVICES WHERE CIRCUITS HAVE
BEEN INTERRUPTED BY DEMOLITION WORK TO MAINTAIN CONTINUITY.
PROVIDE NEW CONNECTIONS TO ANOTHER EXISTING DEVICE OR NEW
CIRCUIT BREAKER FROM PANELBOARD. VERIFY CIRCUIT LOADING ON
EXISTING CIRCUITS BEFORE MAKING THESE CONNECTION.
9. WHERE EXISTING DEVICES TO BE REMOVED ARE SHOWN ON THESE
DRAWINGS, THE CONTRACTOR SHALL ALSO REMOVE ALL WIRING,
CONDUIT, AND BOXES SERVING THE DEVICES, UNLESS CONDUIT AND
BOXES CAN BE REUSED IN NEW CONSTRUCTION.
10. CONDUIT ROUTING ON DRAWINGS IS ESSENTIALLY DIAGRAMMATIC.
CONTRACTOR SHALL LAYOUT RUNS TO SUIT FIELD CONDITIONS,
LIMITING BENDS AND BOXES, AND SHALL COORDINATE INSTALLATION
WITH WORK OF OTHER TRADES.
11. ALL CONDUIT AND RACEWAY PENETRATIONS THROUGH FIRE-RATED
WALLS OR FLOORS SHALL BE UL LISTED ASSEMBLIES THAT PROTECTS
THE RATED ASSEMBLY. SEE ARCHITECTURAL DRAWINGS FOR
LOCATIONS OF ALL RATED WALLS AND FLOORS AS APPLICABLE.
12. ALL CONNECTIONS TO MECHANICAL AND PLUMBING EQUIPMENT SHALL
BE MADE WITH A MINIMUM OF 36” SEALTIGHT FLEXIBLE METAL CONDUIT
TO PREVENT SOUND AND VIBRATION TRANSMISSION TO THE
STRUCTURE.
13. PROVIDE PROTECTION FROM PHYSICAL DAMAGE FOR ALL ELECTRICAL
EQUIPMENT, LUMINAIRES, WIRING DEVICES, ETC., DURING THE
CONSTRUCTION OF THE PROJECT.
C
CEC
(E)
EC
EF
EP
FMC
GFCI
GND
GRC
IMC
MCB
MLO
MT
(N)
NIEC
NTS
OC
OFCI
(R)
TYP
UON
V
VA
WP
2SP
1Ø
3Ø
1P
2P
3P
3W
4W
ABBREVIATIONS
CONDUIT
CALIFORNIA ELECTRICAL CODE
EXISTING TO REMAIN
ELECTRICAL CONTRACTOR
EXHAUST FAN
EXPLOSION PROOF
FLEXIBLE METAL CONDUIT
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
GALVANIZED RIGID CONDUIT
INTERMEDIATE METAL CONDUIT
MAIN CIRCUIT BREAKER
MAIN LUGS ONLY
EMPTY CONDUIT
NEW
NOT IN ELECTRICAL CONTRACT
NOT TO SCALE
ON CENTER
OWNER FURNISHED CONTRACTOR
INSTALLED
EXISTING TO BE REMOVED
TYPICAL
UNLESS OTHERWISE NOTED
VOLTS
VOLTS-AMPS
WEATHERPROOF
TWO SPEED
1-PHASE
3-PHASE
1-POLE
2-POLE
3-POLE
3-WIRE
4-WIRE
No. Date Description
02-07-25 50% WORKING DRAWINGS
05-09-25 95% WORKING DRAWINGS
07-16-25 100% WORKING DRAWINGS
V1
25-S-2521-C
07-16-25
STORAGE
ROOM
RM 38
CLASSROOM
RM 36
CLASSROOM
RM 31
JAN CL
RM 39
CLASSROOM
RM 37
CLASSROOM
RM 6
TOILET
RM 13
TOILET
RM 10
TOILET
RM 9
WTR HTR RM
RM 14
CLASSROOM
RM 8
CLASSROOM
RM 7
CLASSROOM
RM 3
TOIL…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .