Perdido_Class_I_Landfill_2026_Northeast_Pond_Improvements_20260227.pdf
PDF 5 MB Posted
- Attached to
- Perdido Landfill Northeast Pond Improvements
- Solicitation number
- PD 25-26.056
- Issued by
- Escambia County, Canal Point CDP, Florida
About this file
This is a bid drawing set for the Perdido Class I Landfill 2026 Northeast Pond Improvements project prepared by HDR Engineering, Inc. for Escambia County, Florida, issued for bid on February 27, 2026. The project encompasses comprehensive stormwater management improvements to the northeast pond at the Perdido Class I Landfill facility located at 13009 Beulah Road in Cantonment, Florida, and includes site grading, underdrain system installation, erosion and sediment control measures, and landscaping. Key quantities include approximately 3,042 cubic yards of cut material and 142 cubic yards of fill; 1,141 linear feet of 4-inch HDPE perforated collection pipe; 767 linear feet of 4-inch HDPE solid wall riser cleanout pipe; 307 linear feet of 12-inch HDPE perforated header pipe; and 65 linear feet of 12-inch HDPE solid wall discharge pipe. The project requires a mandatory pre-bid meeting scheduled for March 16, 2026 at 12:30 p.m., with a question deadline of March 25, 2026 at 10:00 a.m. and bid submissions due April 6, 2026 at 1:00 p.m. Work must be substantially completed within 90 consecutive calendar days from Notice to Proceed, with an additional 30 days allowed for final completion, totaling 120 calendar days maximum.
Contractors must provide lump sum pricing for nine line items and submit a bid bond, cashier's check, or certified check equal to 5% of the total bid price. The contractor shall obtain performance and payment bonds covering up to 100% of the award value and maintain comprehensive insurance coverage including workers' compensation with statutory limits, general liability of $1,000,000 per occurrence and $2,000,000 annual aggregate, business auto liability of $1,000,000 per accident, and contractor's pollution liability of $1,000,000 per occurrence and $2,000,000 annual aggregate. All materials must comply with strict specifications including AASHTO gravel gradations, HDPE piping conforming to ASTM F 714, and infiltration sand classified as SW or SP with minimum permeability of 2×10⁻³ cm/sec. Prequalification testing results from an approved third-party laboratory are required before material delivery. The contractor must provide as-built survey documentation by a Florida-registered professional land surveyor and comply with OSHA requirements, E-Verify verification, and various compliance certifications. Liquidated damages are assessed at $1,685.00 per calendar day for work extending beyond the completion deadline, and a one-year warranty on all labor and materials is required following project completion.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
PROJECT
VICINITY
Perdido Class I Landfill 2026 Northeast Pond Improvements
Project No.
B i d D r a w i n g s F o r
10435192
February 2026
I N D E X O F D R A W I N G S
GENERAL
00G-00 COVER SHEET
CIVIL
00C-01 EXISTING CONDITIONS
00C-02 PROPOSED POND GRADING PLAN
00C-03 PROPOSED UNDERDRAIN SYSTEM PLAN
00C-04 EROSION AND SEDIMENT CONTROL PLAN
00C-05 DETAILS
00C-06 SPECIFICATIONS
HDR ENGINEERING, INC.
76 SOUTH LAURA ST., SUITE 1600
JACKSONVILLE, FLORIDA 32202-4321
(904) 598-8900
Escambia County, FL
CONTACT: KANISHKA PERERA PHD, PE
FLORIDA REGISTRATION NO. 67647
105 110
CP 1
N 585018.89 E 1058432.48
EL. 124.32
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
NOTES:
1. EXISTING CONDITIONS INSIDE SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY ESCAMBIA COUNTY ENGINEERING DEPARTMENT, DATED JANUARY 12, 2026.
EXISTING CONDITIONS OUTSIDE OF SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY KUCERA INTERNATIONAL, INC., DATED APRIL 23, 2023.
LEGEND
EXISTING CONTOUR (MAJOR)
EXISTING CONTOUR (MINOR)
PROPERTY BOUNDARY
EXISTING CONDITIONS
00C-01 00C-01.dwg 1" = 50'
BU
LA
H
RO
AD
LANDFILL PERIMETER ROAD
RIP RAP
CONCRETE SPILLWAY
END WALL
4'X5' OUTFALL STRUCTURE
SURVEY LIMITS (SEE NOTE 1)
SURVEY LIMITS
18"Ø CMP
36"Ø RCP
(2) 24"Ø RCP
24"Ø RCP
48"Ø RCP
(2) 48"Ø CPP
MITERED END SECTION
LIMITS OF WETLANDS
SITE CONTROL POINT TABLE
POINT NO. NORTHING EASTING ELEVATION
CP 1 585018.89 1058432.48 124.32
CP 2 581893.46 1058153.05 63.54
CP 3 582979.02 1055730.06 63.04
CP 4 585868.89 1056060.35 123.32
CP 5 585877.32 1056325.10 126.88
CP 6 585508.63 1057471.58 132.58
CONTROL POINT
CLEANOUT
(TYP.)
CONCRETE
RETAINING WALL
24"Ø RCP
MITERED END SECTION
0+
1+00
2+00
3+00 3+50
0+00
1+00
2+0
3+
110 105
EL 101.00
-0.50%
-0.50%
-0 .50
-0.50%
-0.50%
-0.50%
3:1
3:1
3:1
3:1
CP 1
N 585018.89 E 1058432.48
EL. 124.32
B 00C-02
A 00C-02
ELEVATION EL
EV
AT
IO
N
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00
ELEVATION EL
EV
AT
IO
N
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50
HORIZONTAL SCALE: 1" = 50' | VERTICAL SCALE: 1" = 10
SECTION AA
00C-02
HORIZONTAL SCALE: 1" = 50' | VERTICAL SCALE: 1" = 10
SECTION BB
00C-02
PROPOSED GRADE
EXISTING GRADE
PROPOSED GRADE
EXISTING GRADE
EL. 101.00
0.5% 0.5%
0.5% 0.5%
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
NOTES:
1. EXISTING CONDITIONS INSIDE SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY ESCAMBIA COUNTY ENGINEERING DEPARTMENT, DATED JANUARY 12, 2026.
EXISTING CONDITIONS OUTSIDE OF SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY KUCERA INTERNATIONAL, INC., DATED APRIL 23, 2023.
LEGEND
EXISTING CONTOUR (MAJOR)
EXISTING CONTOUR (MINOR)
PROPERTY BOUNDARY
PROPOSED POND GRADING PLAN
00C-02 00C-02.dwg 1" = 50'
BU
LA
H
RO
AD
LANDFILL PERIMETER ROAD
EXISTING RIP RAP
EXISTING CONCRETE SPILLWAY
EXISTING END WALL
EXISTING 4'X5'
OUTFALL STRUCTURE
SURVEY LIMITS (SEE NOTE 1)
SURVEY LIMITS
EXISTING 18"Ø CMP
EXISTING 36"Ø RCP
EXISTING (2) 24"Ø RCP
EXISTING 24"Ø RCP
EXISTING 48"Ø RCP
EXISTING (2) 48"Ø CPP
EXISTING MITERED END SECTION
LIMITS OF WETLANDS
EXISTING CLEANOUTS
TO BE REMOVED
(TYP.)
PROPOSED CONTOUR (MAJOR)
PROPOSED CONTOUR (MINOR)
CONTROL POINT
APPROXIMATE EARTHWORK QUANTITIES
CUT 3042 CY
FILL 142 CY
NET 2900 CY CUT
EXISTING CONCRETE
RETAINING WALL
EXISTING 24"Ø RCP
EXISTING
MITERED END SECTION
EXISTING RIP RAP
0+00
1+00
2+00
-0.50%
-0.50%
-0.50%
-0.50%
-0.50%
00C-05
00C-05
00C-05
00C-05
20.0' (TYP.)
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
NOTES:
1. EXISTING CONDITIONS INSIDE SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY ESCAMBIA COUNTY ENGINEERING DEPARTMENT, DATED JANUARY 12, 2026.
EXISTING CONDITIONS OUTSIDE OF SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY KUCERA INTERNATIONAL, INC., DATED APRIL 23, 2023.
2. A MINIMUM 0.5% SLOPE SHALL BE MAINTAINED FOR ALL UNDERDRAIN PIPES.
3. THE POND BOTTOM GRADES SHOW BOTTOM OF SAND INFILTRATION LAYER
LEGEND
EXISTING CONTOUR (MAJOR)
EXISTING CONTOUR (MINOR)
PROPERTY BOUNDARY
PROPOSED UNDERDRAIN SYSTEM PLAN
00C-03 00C-03.dwg 1" = 20'
BU
LA
H
RO
AD
LANDFILL PERIMETER ROAD
EXISTING RIP RAP
EXISTING CONCRETE SPILLWAY
EXISTING END WALL
EXISTING 4'X5'
OUTFALL STRUCTURE
SURVEY LIMITS (SEE NOTE 1)
SURVEY LIMITS
EXISTING 18"Ø CMP
EXISTING 36"Ø RCP
EXISTING (2) 48"Ø CPP
EXISTING MITERED END SECTION
LIMITS OF WETLANDS
PROPOSED CONTOUR (MAJOR)
PROPOSED CONTOUR (MINOR)
4"Ø COLLECTION HDPE SDR 17
PERFORATED UNDERDRAIN PIPE
4"Ø COLLECTION/12"Ø HEADER HDPE SDR 17
SOLID WALL SIDESLOPE RISER PIPE WITH BLIND FLANGE
HDPE FUSED END CAP
12"Ø HDPE SDR 17 SOLID WALL
DISCHARGE PIPE
00C-05
COLLECTION PIPE SIDESLOPE RISER CLEANOUT
(TYP.)
00C-05
HEADER PIPE SIDESLOPE RISER CLEANOUT
DISCHARGE PIPE PROFILE
MATERIAL QUANTITIES
4"Ø HDPE SDR 17 UNDERDRAIN PERFORATED
COLLECTION PIPE 1141 LF
4"Ø HDPE SDR 17 UNDERDRAIN SOLID WALL
SIDESLOPE RISER CLEANOUT PIPE 767 LF
12"Ø HDPE SDR 17 UNDERDRAIN PERFORATED
COLLECTION PIPE 307 LF
12"Ø HDPE SDR 17 UNDERDRAIN SOLID WALL
SIDESLOPE RISER CLEANOUT AND DISCHARGE PIPE 65 LF
EXISTING MITERED END SECTION
EXISTING 24"Ø RCP
EXISTING CONCRETE
RETAINING WALL
12"Ø HEADER HDPE SDR 17
PERFORATED UNDERDRAIN PIPE
CP 1
N 585018.89 E 1058432.48
EL. 124.32
SF
SF
SF
SF
SF
SF
LOD
LOD
LOD
LOD LOD
LOD
LOD
LOD LOD
LO
D
LO
D
LO
D
LO
D
LOD
LO
D
SF
SF
SF SF SF
SF
SF
SF
105110115115
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
NOTES:
1. EXISTING CONDITIONS INSIDE SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY ESCAMBIA COUNTY ENGINEERING DEPARTMENT, DATED JANUARY 12, 2026.
EXISTING CONDITIONS OUTSIDE OF SURVEY LIMITS BASED ON TOPOGRAPHIC SURVEY
PROVIDED BY KUCERA INTERNATIONAL, INC., DATED APRIL 23, 2023.
2. PROPOSED CONTOURS REPRESENT SIDESLOPES AND BOTTOM OF POND GRADING.
STONE AND SAND DRAINAGE LAYERS NOT GRADED PER THIS PLAN. CONTRACTOR SHALL
CONSTRUCT PER THE SECTION DETAILS SHOWN IN THESE DRAWINGS.
3. RIP RAP TO BE PLACED ON TOP OF SAND INFILTRATION LAYER AND UNDERLAIN BY
SEPARATION GEOTEXTILE.
LEGEND
EXISTING CONTOUR (MAJOR)
EXISTING CONTOUR (MINOR)
PROPERTY BOUNDARY
EROSION AND SEDIMENT CONTROL PLAN
00C-04 00C-04.dwg 1" = 50'
BU
LA
H
RO
AD
LANDFILL PERIMETER ROAD
EXISTING RIP RAP
EXISTING CONCRETE SPILLWAY
EXISTING END WALL
EXISTING 4'X5'
OUTFALL STRUCTURE
SURVEY LIMITS (SEE NOTE 1)
SURVEY LIMITS
EXISTING 18"Ø CMP
EXISTING 36"Ø RCP
EXISTING (2) 24"Ø RCP
EXISTING 24"Ø RCP
EXISTING 48"Ø RCP
EXISTING (2) 48"Ø CPP
EXISTING MITERED END SECTION
WETLANDS
1-FT THICK LAYER OF 6"-9" RIP RAP
UNDERLAIN BY SEPARATION GEOTEXTILE
20'X22'-7" (SEE NOTE 3)
00C-05
CHECK DAM
00C-05
STONE BERM
00C-05
CHECK DAM
SILT FENCE
CHECK DAM
SF SF
00C-05
SILT FENCE
(TYP.)
RIP RAP (SEE NOTE 3)
PROPOSED CONTOUR (MAJOR) (SEE NOTE 2)
PROPOSED CONTOUR (MINOR) (SEE NOTE 2)
CONTROL POINT
EXISTING CONCRETE
RETAINING WALL
EXISTING 24"Ø RCP
EXISTING MITERED END SECTION
4"Ø COLLECTION HDPE SDR 17
PERFORATED UNDERDRAIN PIPE
4"Ø COLLECTION/12"Ø HEADER HDPE SDR 17
SOLID WALL SIDESLOPE RISER PIPE WITH BLIND FLANGE
HDPE FUSED END CAP
12"Ø HEADER HDPE SDR 17
PERFORATED UNDERDRAIN PIPE
SOD
REGRADED SIDESLOPES TO BE SODDED
1-FT THICK LAYER OF 6"-9" RIP RAP
UNDERLAIN BY SEPARATION GEOTEXTILE
20'X11'-8" (SEE NOTE 3)
00C-05
STONE BERM
00C-05
STONE BERM
STONE BERM
LIMITS OF DISTURBANCELOD
3 4"Ø HDPE SDR 17 PERFORATED COLLECTION PIPE/
12"Ø HDPE SDR 17 PERFORATED HEADER PIPE
WOVEN GEOTEXTILE
SEPARATION LAYER
2.0' INFILTRATION LAYER
2X10-3 CM/S MIN. PERMEABILITY
4"Ø OR 12" HDPE SDR 17 SOLID RISER PIPE
4"Ø OR 12"Ø HDPE BLIND FLANGE
4"Ø OR 12"Ø HDPE SDR 17 45° FITTING
4"Ø OR 12"Ø HDPE SDR 17 22.5° FITTING
2'- 0"
6"
3"
2'- 0"
M
IN
2'- 0"
00C-05
PIPE PERFORATION
NOT TO SCALE
COLLECTION/HEADER PIPE SIDESLOPE RISER CLEANOUT1
00C-03
6" LAYER AASHTO #8 STONE
1'-0"
2'- 0"
2' (4" HDPE)
3' (12" HDPE)
4"Ø OR 12"Ø HDPE SDR 17 PIPE
LATERAL/HEADER SECTION A-A
(NOT TO SCALE)
A
A
AASHTO #57 STONE
NOT TO SCALE
PIPE SECTION2
00C-03
AASHTO #57 STONE
4"Ø HDPE SDR 17 PERFORATED COLLECTION PIPE/
12"Ø HDPE SDR 17 PERFORATED HEADER PIPE
2.0' SAND INFILTRATION LAYER
2X10-3 CM/S MIN. PERMEABILITY
NON-WOVEN GEOTEXTILE
SEPARATION LAYER
AASHTO #8 STONE
2.0' MIN.
2.0 ' M
IN
2.0 ' M
IN
6" 6"
3"
1.0'
1.5'1.5'
5/8"Ø HOLES
4"Ø OR 12"Ø HDPE SDR 17 PIPE
(FOUR ROWS OF PERFORATION)
HDPE END CAP
PLAN
SECTION
120°
6" 3"
NOT TO SCALE
PIPE PERFORATION3
00C-05
A
A
6' MAX.
POST
POST
10' MAX.
LC
MATERIALS
1. SYNTHETIC FILTER FABRIC SHALL BE A PERVIOUS SHEET OF POLYPROPYLENE, NYLON POLYESTER, OR ETHYLENE YARN AND SHALL BE CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE
FOLLOWING REQUIREMENTS:
PHYSICAL PROPERTY TEST REQUIREMENTS
FILTERING EFFICIENCY ASTM D-5141 75% (MIN)
TENSILE STRENGTH AT VTM-52 EXTRA STRENGTH-
20% (MAX.) ELONGATION* 50 LBS./IN. (MIN.)
STANDARD STRENGTH-
30 LBS./IN. (MIN.)
FLOW RATE ASTM D-5141 0.3 GAL./SQ. FT./MINUTE
ULTRAVIOLET RADIATION ASTM D-4355 90% (MIN.)
AND G-28
* REQUIREMENTS REDUCED BY 50% AFTER 6 MONTHS OF INSTALLATION.
2. SYNTHETIC FILTER FABRIC SHALL CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 F TO 120 F.
NOTES:
TEMPORARY SILT FENCE IS TO BE
CONSTRUCTED IN ACCORDANCE WITH FDOT
SECTION 104.
"M
IN
"M
AX
"M
IN
"M
AX
2'O.C.
MAX
4'O.C.
MAX
NOT TO SCALE
SILT FENCE7
00C-04
CONSTRUCTION SPECIFICATIONS
SECTION A-A
STANDARD STRENGTH FILTER CLOTH FABRICEXTRA STRENGTH FILTER CLOTH FABRIC
(WITHOUT WIRE)
TRENCH
TOE OF FILL
FENCE
TRENCH
FENCE
TRENCH
FENCE
FLOW
PROVIDE 1" TUCK OR
SUITABLY REINFORCED
TOP END SECTION
EMBED APPROXIMATELY
8" OF FILTER CLOTH
IN TRENCH
TRENCH APPROXIMATELY 4" DEEP X 6" WIDE,
FILL TRENCH TO ANCHOR BOTTOM OF
CLOTH, COMPACT THOUROUGHLY
TIE WIRE OR HOG RINGS
WIRE FABRIC, 14 GAUGE
MIN. 6" MESH SPACING
INSTALL WIRE FENCE
FLUSH WITH THE GROUND
EMBED POST
2' MINIMUM
LC
NOTES:
1. THE DAM SHOULD NOT BE HIGHER THAN THE CHANNEL BANKS. THE CENTER OF THE ROCK DAM SHOULD BE AT LEAST SIX INCHES LOWER THAN THE OUTER EDGES OF THE DAM AT THE CHANNEL
BANKS.
2. SIDES SLOPES SHALL BE 2:1 OR FLATTER.
3. A GEOTEXTILE SHOULD BE USED AS A SEPARATOR BETWEEN THE GRADED STONE AND THE SOIL
BASE AND ABUTMENTS. THE GEOTEXTILE SHOULD BE PLACED IMMEDIATELY ADJACENT TO THE
SUBGRADE WITHOUT ANY VOIDS AND EXTEND FIVE FEET BEYOND THE DOWNSTREAM TOE OF THE
DAM TO PREVENT SCOUR.
4. MECHANICAL OR HAND PLACEMENT WILL BE REQUIRED TO INSURE THAT THE ROCK DAM EXTENDS
COMPLETELY ACROSS THE CHANNEL AND SECURELY TIES INTO BOTH CHANNEL BANKS. THE
CENTER OF THE DAM MUST BE NO LESS THAN SIX INCHES LOWER THAN THE LOWEST SIDE, TO
SERVE AS A TYPE OF WEIR. GABIONS CAN BE INSTALLED TO SERVE AS ROCK FILTER DAMS, BUT
SHOULD FOLLOW RECOMMENDED SIZING AND INSTALLATION.
5. PERIODIC INSPECTION AND REQUIRED MAINTENANCE MUST BE PROVIDED. SEDIMENT SHALL BE
REMOVED WHEN IT REACHES A DEPTH OF ONE-HALF OF THE ORIGINAL HEIGHT OF THE DAM.
6. ROCK DAMS SHOULD BE REMOVED ONCE DISTURBED AREAS HAVE BEEN STABILIZED.
NOT TO SCALE
CHECK DAM6
00C-04
6"
6"
2'- 0"
RIP RAP 9" MAX.
6" MIN.
GEOTEXTILEAASHTO #57 STONE
2:1 MAX.
2:1 MAX.FLOW
-0+50 0+00 0+50 1+00 1+50 2+00
EXISTING 18"Ø CMP
EL 101.33
12"Ø HDPE SDR 17 TEE FITTING
REMOVE EXISTING 12"Ø PVC AND
REPLACE WITH NEW 12"Ø HDPE SDR 17
SOLID WALL PIPE
12"Ø HDPE SDR 17
SOLID WALL DISCHARGE PIPE
EXISTING GRADEEXISTING OUTFALL STRUCTURE
EXISTING ENDWALL
HORIZONTAL SCALE: 1" = 20' | VERTICAL SCALE: 1" = 10
DISCHARGE PIPE PROFILE4
00C-03
AASHTO #57 STONE
12"Ø HDPE SDR 17
PERFORATED HEADER PIPE
6" AASHTO #8 STONE
2.0' INFILTRATION LAYER
2X10-3 CM/S MIN. PERMABILITY
PROPOSED
STONE BERM
12"Ø HDPE SDR 17
PERFORATED PIPE
3'
PROPOSED GRADE SOD
PROVIDE LINK-SEAL® OR SIMILAR
WATER-TIGHT CONNECTION
NOT TO SCALE
STONE BERM5
00C-04
2'- 6"
(M
IN
6'-0"
VARIES
FLOW
6"-9" RIP RAP
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
DETAILS
00C-05 00C-05.dwg
NOT TO SCALE
B
ISSUE DESCRIPTION
PROJECT MANAGER
PROJECT NUMBER
0 1" 2"
FILE NAME
SCALE
SHEET
DATE
C
A
1 3 4 5 6 7 8
C:
\P
W W
OR
KI
NG
\E
AS
T0
2\D
7\0 0G
-B D2
2-
.D W
G
/08 /20
:57 :56
A M
DESIGNED BY
DRAWN BY
CHECKED BY
A 02/27/2026 ISSUED FOR BID
PERDIDO CLASS I LANDFILL
2026 NORTHEST POND IMPROVEMENTS
ESCAMBIA COUNTY, FLORIDA
K. PERERA, P.E.
10435192
K. PERERA, P.E.
J. RAYMOND
T. YANOSCHAK. P.E.
HDR ENGINEERING, INC.
8333 NW 53RD ST., SUITE 302
DORAL, FL 33166-4786
(305) 728-7400
SPECIFICATIONS
00C-06 00C-06.dwg
SPECIFICATIONS:
A. CONTRACTOR SHALL TAKE ALL REQUIRED PRECAUTIONS TO PROTECT THE WORK IN CASE OF A RAIN EVENT DUE TO INCOMING STORMWATER FLOW INTO THE POND. OWNER SHALL NOT BE HELD RESPONSIBLE FOR ANY WEATHER RELATED DAMAGE TO ESTABLISHED WORK AS A RESULT OF A RAIN EVENT. IF THE SAND INFILTRATION LAYER GETS CONTAMINATED WITH SEDIMENT DURING CONSTRUCTION, THE CONTRACTOR SHALL REPLACE INFILTRATION LAYER
WITH UNCONTAMINATED SAND WITHOUT ANY EXPENSE TO THE OWNER.
B. ESTABLISH EROSION AND SEDIMENT CONTROL METHODS IDENTIFIED IN THE DRAWINGS. CONTRACTOR MAY ADD ADDITIONAL EROSION AND SEDIMENT
CONTROL METHODS DEPENDING ON CONTRACTOR'S SEQUENCE OF CONSTRUCTION.
C. THE EXISTING INFILTRATION LAYER, GRAVEL AND PIPING SHALL BE REMOVED AND DISPOSED AT THE ACTIVE CLASS I LANDFILL. THE PRINCIPAL OUTLET STRUCTURE AND EMERGENCY SPILLWAY SHALL REMAIN UNDISTURBED. THE SIDE SLOPE OF THE POND SHALL BE GRADED AND COMPACTED SMOOTH TO MEET THE GRADES SHOWN IN THE DRAWINGS. THE TOPSOIL WITHIN THE SIDESLOPES SHALL BE SCRAPED (6-INCH MINIMUM) AND STOCKPILED FOR REUSE.
THE RECOVERED TOPSOIL SHALL NOT BE CONTAMINATED WITH VEGETATION DEBRIS. IF ADDITIONAL STRUCTURAL FILL MATERIAL IS NEEDED, IT CAN BE OBTAINED FROM THE OWNER'S SOIL STOCKPILE LOCATED NORTH OF THE ADMINISTRATION BUILDING.
D. AGGREGATE SHALL CONSIST OF HARD, STRONG, DURABLE PARTICLES UNLESS OTHERWISE SPECIFIED THAT ARE FREE OF ANY METAL, ROOTS, CONCRETE, DEBRIS, ORGANICS, AND OTHER DELETERIOUS MATERIALS AND COATINGS.
E. OFFSITE GRAVEL MATERIAL SHALL MEET AASHTO NO. 57 AND AASHTO #8 GRADATION AT LOCATIONS SHOWN IN THE DRAWINGS. THE RIP-RAP FOR CHECK DAMS AND OUTLET PROTECTION STRUCTURES SHALL MEET THE DIMENSIONS INDICATED ON THE DRAWINGS.
F. INFILTRATION LAYER SAND SHALL BE OBTAINED FROM OFF-SITE SOURCES APPROVED BY THE ENGINEER AND SHALL BE CLEAN, EXCAVATED, NATURAL SAND, FREE FROM ROOTS, SHARP OBJECTS, OR ORGANIC MATERIAL, WITH A MAXIMUM SIZE OF 1/4 INCH AND 5% MAXIMUM BY WEIGHT PASSING THE NO.
200 SIEVE. THE SAND SHALL BE CLASSIFIED AS SW OR SP BY THE UNIFIED SOIL CLASSIFICATION SYSTEM. THE INFILTRATION LAYER SHALL HAVE A LABORATORY PERMEABILITY NOT LESS THAN 2 X 10-3 CM/SEC AT 90% RELATIVE COMPACTION (ASTM D 698).
G. THE CONTRACTOR SHALL PROVIDE PREQUALIFICATION TEST RESULTS FROM A THIRD-PARTY LABORATORY APPROVED BY THE ENGINEER OF THE INFILTRATION LAYER FOR THE PARAMETERS HEREIN SPECIFIED. THE TESTS SHALL BE PERFORMED AT A MINIMUM FREQUENCY OF ONE PER BORROW
SOURCE AND/OR CHANGE IN MATERIAL.
H. ENGINEER RETAINS THE RIGHT TO PERFORM ADDITIONAL TESTING OF INFILTRATION SAND IF DEEMED NECESSARY DURING CONSTRUCTION TO CONFIRM
THAT REQUIRED MINIMUM PHYSICAL PARAMETERS ARE MET.
I. ANY MATERIAL DELIVERED TO SITE THAT ARE NOT MEETING MINIMUM SPECIFICATIONS SHALL BE REJECTED AT NO COST TO THE OWNER.
J. HDPE PIPING AND FITTINGS SHALL BE PROVIDED IN THE SIZES AND SHALL HAVE A STANDARD DIMENSION RATIO (SDR) AS INDICATED ON THE DRAWINGS.
DIMENSIONS AND WORKMANSHIP SHALL CONFORM TO THE REQUIREMENTS OF ASTM F 714.
K. PERFORATIONS SHALL BE DRILLED INTO THE PIPE AT THE PIPE EXTRUSION PLANT OR FABRICATION SHOP. ANY BURRS REMAINING AFTER DRILLING SHALL
BE REMOVED. PERFORATIONS SHALL BE DRILLED AND DEBURRED PRIOR TO PIPE DELIVERY TO THE JOB SITE. JOB SITE PERFORATION OR PERFORATION
BY THE CONTRACTOR SHALL NOT BE PERMITTED.
L. THE SEPARATION GEOTEXTILE PHYSICAL PROPERTIES SHALL EQUAL OR EXCEED THE MINIMUM AVERAGE ROLL VALUES LISTED IN THE TABLE BELOW.
VALUES SHOWN ARE FOR THE WEAKER PRINCIPAL DIRECTION. ACCEPTANCE OF GEOTEXTILE SHALL BE IN ACCORDANCE WITH ASTM D4759.
M. OVERLAPPING GEOTEXTILE SHALL BE THERMALLY BONDED.
N. INSTALL SEPARATION GEOTEXTILE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS.
O. GEOTEXTILE LEFT UNCOVERED FOR MORE THAN 14 DAYS SHALL BE REMOVED AND REPLACED AT THE CONTRACTOR'S EXPENSE P. INTERIOR SLOPES OF THE POND SHALL BE SODDED. A MINIMUM 6-INCH LAYER OF TOPSOIL SHALL BE INSTALLED BEFORE INSTALLATION OF SOD. SOD
SHALL BE RECOGNIZED BAHIA GRASS ROLLS CONFORMING TO FDOT STANDARD SPECIFICATION'S SECTION 981-5 AND SHALL BE WELL MATTED WITH ROOTS AND SHALL BE OF FIRM TOUGH TEXTURE HAVING A COMPACT TOP GROWTH AND HEAVY ROOT DEVELOPMENT. IT SHALL NOT CONTAIN WEEDS OR ANY OTHER OBJECTIONABLE VEGETATION. OTHER SODDING SPECIES MAY BE UTILIZED PURSUANT TO OWNER APPROVAL.
Q. WATER FOR SODDING SHALL CONFORM TO SECTION 983 OF THE FDOT STANDARD SPECIFICATIONS. IN ADDITION, WATERING IS REQUIRED FOR SOD
INSTALLED UNTIL VEGETATION IS ESTABLISHED.
R. CONTRACTOR SHALL PROVIDE AS-BUILT SURVEY SIGNED AND SEALED BY A PROFESSIONAL LAND SURVEYOR REGISTERED IN THE STATE OF FLORIDA. THE SURVEY SHALL INCLUDE TOPOGRAPHIC SURVEY OF THE POND, POND BOTTOM ELEVATIONS, TOP OF INFILTRATION LAYER ELEVATIONS AT 25 FT GRID, TOP
OF PIPE LOCATIONS AND ELEVATIONS AT 25 FT INTERVAL.
ITEM TEST ASTM NO.
INFILTRATION LAYER SOIL CLASSIFICATION (USCS
CLASSIFICATION SYSTEM) D2487
SIEVE AND HYDROMETER ANALYSIS D422
NATURAL MOISTURE CONTENT D2216
STANDARD PROCTOR D698
PERMEABILITY @ 90% OF ASTM D698 D2434
PROPERTY TEST METHOD MARV
ULTRAVIOLET STABILITY, % RETAINED @ 500 HRS ASTM D4355 50%
TEAR STRENGTH, LBS ASTM D4533 79
PUNCTURE STRENGTH, LBS ASTM D4833 79
GRAB TENSILE, LBS ASTM D4632 200
SEWN SEAM STRENGTH, LBS ASTM D4632 180
AOS, IN. (MAX AVE. ROLL VALUE) ASTM D4751 0.024
BURST STRENGTH, PSI
PERMITIVITY, SEC-1
ASTM D3786
ASTM D4491 250
PREQUALIFICATION TESTING
NON-WOVEN SEPARATION GEOTEXTILE PROPERTIES
| Sheets and Views |
| 00G-00-Layout1 |
| 00C-01-Plot |
| 00C-02-Plot |
| 00C-03-Plot |
| 00C-04-Plot |