Part7-00 DRAWINGS.pdf

PDF 19 MB Posted

Attached to
Y1DA--678-328 - Expand/Renovate Clinics Building 80
Solicitation number
36C77624R0025
Issued by

About this file

This document provides details on a federal solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin. The solicitation, numbered 36C77624R0025, is for the expansion and renovation of Clinics Building 80 and seeks to award a contract for construction services. Key information includes the solicitation number, agency and opportunity type listed. No further specifics on required products, services, response dates or other salient details are provided in this document.

View the file

Other files

File Type Posted
36C77624R0025 0006.docx DOCX document
Amendment 06 Att.zip ZIP file
36C77624R0025 0005.docx DOCX document
Amendment 04 Att.zip ZIP file
36C77624R0025 0004.docx DOCX document
36C77624R0025 0003.docx DOCX document
36C77624R0025 0002.docx DOCX document
36C77624R0025 0001.docx DOCX document
S04 - Site Visit Mtg Min - RFP 2-13-2024.doc DOC document
678-328 Bid Walk Sign In Sheet.pdf PDF
tucson b80 pre-bid presentation rev1.pdf PDF
Part4-00 DRAWINGS.pdf PDF
Part6-00 DRAWINGS.pdf PDF
DBA WD AZ20240040 01.19.2024.pdf PDF
SPECIAL NOTE - BID TAXES - AFTER FAR 52.229-3.docx DOCX document
Site Visit SITE MAP Parking Location1.pdf PDF
Part5-00 DRAWINGS.pdf PDF
PPQ.docx DOCX document
SPEC VOL I.pdf PDF
Part3-00 DRAWINGS.pdf PDF
36C77624R0025_1.docx DOCX document
SPEC VOL II.pdf PDF
Part1-00 DRAWINGS.pdf PDF
Part8-00 DRAWINGS.pdf PDF
Brand Name JA.pdf PDF
Limitations on Subcontracting - Construction.docx DOCX document
Part2-00 DRAWINGS.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: NONE

SCALE: NONE

T

SCALE: NONE

PLUMBING VALVE SYMBOLS

DOMESTIC COLD WATER SUPPLY

DOMESTIC HOT WATER SUPPLY

DOMESTIC HOT WATER RETURN

MEDICAL AIR

OXYGEN

MEDICAL VACUUM

DRAIN

VENT, SANITARY

SANITARY SEWER

STORM WATER

CHECK VALVE

BALL VALVE

TEST PLUG

BALANCING VALVE

VALVE ON RISER

PIPE REDUCER

TOP CONNECTION, 45° OR 90°

BOTTOM CONNECTION, 45° OR 90°

SIDE CONNECTION

WATER HAMMER ARRESTOR

RISE OR DROP IN PIPE

UNION

PIPE UP

PIPE DOWN

HOSE BIBB

NON-FREEZE WALL HYDRANT

FLOOR DRAIN

HUB DRAIN

PLUGGED TEE

WALL CLEANOUT

PUMP

NEW WORK CONNECTION

LIMIT OF DEMOLITION

LOCKED OPEN IN LINE VALVE

LOCKED CLOSED IN LINE VALVE

LOCAL ALARM PANEL

VALVE BOX RECESSED

PRESSURE AND VACUUM

TRANSDUCER SWITCH

MAIN LINE GAUGE

MEDICAL INLET/OUTLET DISS TYPE

THERMOSTATIC BALANCING VALVE WITH INTEGRAL CHECK VALVE

AND UNION. CONTRACTOR SHALL PROVIDE THERMOSTATIC

BALANCING VALVE. MINIMUM SIZE SHALL BE 3/4".

ISOLATION VALVE. (BALL VALVE)

UNION.

PETES PLUG.

DIGITAL THERMOMETER.

PLUGGED 3/4" FIP ADAPTER FOR FUTURE BUILDING MANAGEMENT

SYSTEM SENSOR CONNECTION. SEE THERMOWELL AND

APPARATUS DETAIL THIS SHEET.

REDUCER FOR LINE SIZE ADJUSTMENT. SEE DETAIL ON THIS SHEET.

REDUCER FOR LINE SIZE ADJUSTMENT (IF REQUIRED).

(BALANCING VALVE ASSEMBLY DETAIL ONLY)

FITTING REDUCER

PLUGGED 3/4" FIP ADAPTER FOR FUTURE (NIC) CONTROL

CONTRACTOR SUPPLIED THERMOWELL AND SENSOR

(INSTALLED

BY PLUMBING CONTRACTOR).

3/4" FIP ADAPTOR FOR THERMOWELL INSERTION.

THERMOWELL AND DIGITAL THERMOMETER AS SPECIFIED.

REDUCER AS NEEDED FOR ALL PIPE SIZES 1/2" THROUGH 1 1/2".

2" X 3/4" TEE.

(THERMOWELL AND APPARATUS DETAIL ONLY)

5 6

FOOTER

CONCRETE

COLUMN

SANITARY OR

STORM PIPE

SANITARY OR

STORM PIPE

NOTES:

NOTES:

WATER RETURN BALANCING

VALVE ASSEMBLY DETAIL

THERMOWELL AND APPARATUS DETAIL

PIPE AND FOOTER DETAIL

778 1

PLUMBING PIPING SYMBOLS

GENERAL PLUMBING SYMBOLS

SPECIALITIES PLUMBING SYMBOLS

SDSD

MAMA

MVMV

OXOX

SSSS

DD

PLUMBING ABBREVIATIONS

CONTRACTOR GENERAL NOTES

LEGEND

A. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE NOT TO BE

SCALED. FIELD VERIFY ALL DIMENSIONS, PIPE SIZES, AND INVERTS.

REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND

LOCATIONS OF ALL PLUMBING FIXTURES AND EQUIPMENT.

B. COORDINATE PIPE ROUTING WITH DUCT ROUTING, EQUIPMENT

LOCATIONS, ELECTRICAL INSTALLATIONS, AND BUILDING STRUCTURAL

MEMBERS. OFFSET PIPING WHERE REQUIRED TO AVOID CONFLICTS.

AVOID PENETRATING ANY MAIN STRUCTURAL BEAM. NOTIFY COR OF ANY

CONFLICTS.

C. CONTRACTOR SHALL REMOVE AND REPAIR/RESTORE ALL

PENETRATIONS, HOLES, VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS,

INDENTS, CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS, MARKS,

RECESSES, BAYS, INLETS, AND ANY COVES IN FLOORS, CEILINGS, AND

WALLS AND/OR SLABS AFFECTED BY PLUMBING MODIFICATIONS OR

WHICH ARE DISCOVERED DURING DEMOLITION BACK TO THE ORIGINAL

BASE MATERIAL OR BETTER COMPLYING WITH WATER TIGHT OR FIRE

RETARDANT CONDITIONS.REPAIR SURFACES TO MATCH EXISTING

UNLESS OTHERWISE NOTED ON ARCHITECTURAL DRAWINGS.

D. WHERE CHASES ARE NOT PRESENT, CONNECT VENT PIPING TOGETHER

IN CEILING SPACE IF POSSIBLE TO AVOID CUTTING THROUGH STUDS.

E. PRIOR TO PERFORMING ANY PLUMBING WORK OR PURCHASING ANY

MATERIALS VERIFY EXACT LOCATION, ROUTING, AND PIPE SIZES, ETC.

OF ALL EXISTING WASTE, DRAIN, VENT, DOMESTIC WATER SUPPLY AND

RETURN PIPING.

F. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL PLUMBING

CODE, LOCAL CODE, BOTTOM OF STACKS, AND WHERE HORIZONTAL

SANITARY SEWER PIPING CHANGES DIRECTION OVER 45°.

G. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A MINIMUM OF TWO

PERCENT, ONE-QUARTER INCH PER FOOT. NEW 3" AND 4" SANITARY

SEWER PIPING SHALL BE SLOPED A MINIMUM OF ONE PERCENT,

ONE-EIGHTH INCH PER FOOT.

AC ABOVE CEILING

AFF ABOVE FINISH FLOOR

AFG ABOVE FINISH GRADE

ASHRAE AMERICAN SOCIETY OF

HEATING,

REFRIGERATION,

AIR CONDITIONING

ENGINEERS

ASME AMERICAN SOCIETY

OF MECHANICAL

ENGINEERS

ASPE AMERICAN SOCIETY

OF

PLUMBING ENGINEERS

ASR AUTOMATIC

RISER

BF BELOW FLOOR

CFM CUBIC FEET PER

COTG CLEANOUT TO GRADE

MINUTE

DCWS DOMESTIC COLD

DFU DRAINAGE FIXTURE

WATER SUPPLY

UNITS

DHWR DOMESTIC HOT

WATER RETURN

DHWS DOMESTIC HOT

WATER SUPPLY

DN DOWN

EL ELEVATION

DWG DRAWING

ET EXPANSION TANK

EWH ELECTRIC WATER

HEATER

FCO FLOOR CLEANOUT

F FAHRENHEIT

FD FLOOR DRAIN

(HOSE) CONNECTION

FDC FIRE DEPARTMENT

FS FLOW SWITCH

FU FIXTURE UNITS

A/E ARCHITECT / ENGINEER

AG AIR GAP

GAL GALLON

GPM GALLONS PER MINUTE

GT GREASE TRAP

H&CW HOT AND COLD

WATER

HB HOSE BIB

HD HUB DRAIN

HP HORSEPOWER

HYD HYDRANT

INV.EL INVERT ELEVATION

INV INVERT

IPC INTERNATIONAL PLUMBING

CODE

IRW IRRIGATION WATER

KW KILOWATT

KWH KILOWATT-HOUR

AP ACCESS PANEL

SPRINKLER

BG BELOW GRADE

MA MEDICAL AIR

MBH 1000 BTUH

MED MEDICAL

MV MEDICAL VACUUM

NC NORMALLY CLOSED

NTS NOT TO SCALE

OX OXYGEN

OSCO OUTSIDE CLEANOUT

PG PRESSURE GAGE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH

ATMOSPHERE

PSIG POUNDS PER SQUARE INCH

GAGE

RP RECIRULATION PUMP

SS SANITARY SEWER

SCFM STANDARD CUBIC

FOOT/MINUTE

TYP TYPICAL

V VENT

VP VACUUM PUMP

VE VENT EXHAUST

VS VENT STACK

VTR VENT THROUGH ROOF

W WASTE

WCO WALL CLEANOUT

WH WALL HYDRANT

WH WATER HEATER

WHA WATER HAMMER ARRESTOR

WSFU WATER SUPPLY FIXTURE

UNITS

YCO YARD CLEANOUT

DS DOWNSPOUT

RL RAIN WATER LEADER

BF BELOW FLOOR

BG BELOW GRADE

BFP BACKFLOW PREVENTER

NO NORMALLY OPENCENT CENTRIFUGAL

ENT ENTERING

EWT ENTERING WATER

TEMPERATURE

LWT LEAVING WATER

TEMPERATURE

CD CONDENSATE DRAIN

FIP FEMALE IRON PIPE

P.I.D. PLUMBING AND DRAINAGE

QTY QUANTITY

SD STORM DRAINAGE

SAN SANITARY SEWER

INSTITUTECT CURRENT TEMPERATURE

H. ALL WORK ON THE FIRST FLOOR SHALL BE DONE AFTER HOURS.

LPM LITERS PER MINUTE

GCO GRADE CLEANOUTS

GPH GALLONS PER HOUR

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-P-001

ABBREVIATIONS, GENERAL NOTES,

LEGEND, AND DETAILS

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

2 2

4(E

2" V

(D) 2" SS

(E) 2" SS

(D

2" S

S

(D) 2" SS

(E) 6" SD

(E

6" S

D

(D) 3" SD (D) 3" SD

(E

6" S

D

(E) 2" V

(E

2" V

(E

2" V

(E

2" V

(D) 2" SS

(D) 3" V

(E

2" V

(E

4" O

D (E

4"

O D

(D

2" S

S

(E

2" V

(E) 2" SS

(E

2" S

S

(E

2" V

(D

2" S

S (E

2"

S S

(E

2" V

(E

2" V

(E

6" O

D (E

6"

O D

(E

6" O

D (E

6"

O D

(E

6" O

D (E

6"

O D

(E) 3" SD (E) 3" SD

5 5

(E

2" V

(E

2" V

(E) 3" SD

(D) 2" SS

(E) 4" SS

(E) 4" SS

(D

2" S

S

(E

3" V

(E) 3" V(E) 2" V

(E) 2" V(D) 2" SS

(D

2" S

S

(E ) 4

" S S

(E) 3" V

(D

2" S

S (D

2"

S S

(D

2" S

S (E

3"

S D

(E

2" V

(E

6" S

D

(E

3" V

(D

2" S

S (D

2"

S S

(E

2" V

(E

2" V

(E) 2" V

(E

2" V

(E) 2" V

(E) 2" V

(E

2" V

(D) 2" SS

STAFF TOILET

WOMEN'S

HEALTH TOILET

1245A

EXAM/

CONSULT

PACT

WORKROOM

BREAKOUT

WORKROOM

1201D

BREAKOUT

WORKROOM

1201E

PACT

WORKROOM

1202D

COMM

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

CONSULT

CONSULT

H.A.C.

PATIENT

TOILET

1208A

CONSULT

CONSULT

SUB-WAIT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1216A

PACT TEAMLET

AREA B3

C O

R R

ID

O

R

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

1224EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

C L

E A

N S

U P

P L

Y

UTILITY

WOMEN'S

HEALTH

STAFF TOILET

WOMEN'S

HEALTH TOILET

1239A

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1234A

PACT TEAMLET

AREA B2

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

C O

R R

ID

O

R

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PACT TEAMLET

AREA B1

PATIENT

TOILET

1248A

STAFF TOILET

1201C

STAFF TOILET

1201B

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

PATIENT

CIRCULATION

STAFF

CIRCULATION

1290B

STAFF TOILET

1211 WOMEN'S

HEALTH TOILET

1213A

(E)

FCO

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-101

FIRST FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. ALL EXISTING PLUMBING FIXTURES AND ALL ASSOCIATED

PIPING SERVING FIRST FLOOR TO REMAIN.

B. PRIOR TO PERFORMING ANY WORK OR PURCHASING ANY

MATERIALS, THE CONTRACTOR SHALL VERIFY LOCATION OF

EXISTING PLUMBING PIPING.

C. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

D. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

E. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN

FLOORS AND CEILINGS WHICH ARE DISCOVERED DURING

DEMOLITION BACK TO THE ORIGINAL BASE MATERIAL OR

BETTER COMPLYING WITH WATER TIGHT AND/OR FIRE

RETARDANT CONDITIONS. REFER TO ARCHITECTURAL

DRAWINGS FOR ADDITIONAL INFORMATION ON THE FLOOR

AND CEILING REPAIR.

F. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

SCALE: 1/8" = 1'-0"

FIRST FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B

1. LIMITS OF DEMOLITION.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. LIMIT OF DEMOLITION. REMOVE AND DISCARD PIPING TO

BELOW SLAB. CAP PIPING BELOW FLOOR AND REPAIR FLOOR

TO MATCH EXISTING FINISH.

4. LIMIT OF DEMOLITION. CUT EXISTING VENT PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW VENT PIPING DURING NEW

WORK.

5. LIMIT OF DEMOLITION. CUT EXISTING SS PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SS PIPING DURING NEW

WORK.

6. LIMIT OF DEMOLITION. CUT EXISTING SD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SD PIPING DURING NEW

WORK.

7. LIMIT OF DEMOLITION. CUT EXISTING OD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW OD PIPING DURING NEW

WORK.

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

2 2

(E

2" V

(D) 2" SS

(E) 2" SS

(E

2" S

S

(E) 2" SS

(E) 6" SD

(E

6" S

D

(D) 3" SD (D) 3" SD

(E

6" S

D

(E) 2" V

(E

2" V

(E

2" V

(E

2" V

(E) 2" SS

(E) 3" V

(E

2" V

(E

4" O

D (E

4"

O D

(E

2" S

S

(E

2" V

(E) 2" SS

(E

2" S

S

(E

2" V

(D

2" S

S (E

2"

S S

(E

2" V

(E

2" V

(E

6" O

D (E

6"

O D

(E

6" O

D (E

6"

O D

(E

6" O

D (E

6"

O D

(E) 3" SD (E) 3" SD

5 5

(E

2" V

(E

2" V

(E) 3" SD

(D) 2" SS

(E) 4" SS

(E) 4" SS

(D

2" S

S

(E

3" V

(E) 3" V(E) 2" V

(E) 2" V(D) 2" SS

(D

2" S

S

(E ) 4

" S S

(E) 3" V

(D

2" S

S (D

2"

S S

(D

2" S

S (E

3"

S D

(E

2" V

(E

6" S

D

(E

3" V

(D

2" S

S (D

2"

S S

(E

2" V

(E

2" V

(E) 2" V

(E

2" V

(E) 2" V

(E) 2" V

(E

2" V

(E) 2" SS

STAFF TOILET

WOMEN'S

HEALTH TOILET

1245A

EXAM/

CONSULT

PACT

WORKROOM

BREAKOUT

WORKROOM

1201D

BREAKOUT

WORKROOM

1201E

PACT

WORKROOM

1202D

COMM

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

CONSULT

CONSULT

H.A.C.

PATIENT

TOILET

1208A

CONSULT

CONSULT

SUB-WAIT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1216A

PACT TEAMLET

AREA B3

C O

R R

ID

O

R

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

1224EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

STAFF TOILET

WOMEN'S

HEALTH TOILET

1239A

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1234A

PACT TEAMLET

AREA B2

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

C O

R R

ID

O

R

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PACT TEAMLET

AREA B1

PATIENT

TOILET

1248A

STAFF TOILET

1201C

STAFF TOILET

1201B

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

PATIENT

CIRCULATION

STAFF

CIRCULATION

1290B

STAFF TOILET

WOMEN'S

HEALTH TOILET

1213A

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\

D o c u m e n ts

\8

T u c s o n E x p a n d a n d R e n o C lin ic s

D E

D U

C T

P

M a ri o n

.V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-101A

FIRST FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B - ALT. #1

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. ALL EXISTING PLUMBING FIXTURES AND ALL ASSOCIATED

PIPING SERVING FIRST FLOOR TO REMAIN.

B. PRIOR TO PERFORMING ANY WORK OR PURCHASING ANY

MATERIALS, THE CONTRACTOR SHALL VERIFY LOCATION OF

EXISTING PLUMBING PIPING.

C. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

D. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

E. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN

FLOORS AND CEILINGS WHICH ARE DISCOVERED DURING

DEMOLITION BACK TO THE ORIGINAL BASE MATERIAL OR

BETTER COMPLYING WITH WATER TIGHT AND/OR FIRE

RETARDANT CONDITIONS. REFER TO ARCHITECTURAL

DRAWINGS FOR ADDITIONAL INFORMATION ON THE FLOOR

AND CEILING REPAIR.

F. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

SCALE: 1/8" = 1'-0"

FIRST FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B - ALT. #1

1. NOTE NOT USED.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. LIMIT OF DEMOLITION. REMOVE AND DISCARD PIPING TO

BELOW SLAB. CAP PIPING BELOW FLOOR AND REPAIR FLOOR

TO MATCH EXISTING FINISH.

4. LIMIT OF DEMOLITION. CUT EXISTING VENT PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW VENT PIPING DURING NEW

WORK.

5. LIMIT OF DEMOLITION. CUT EXISTING SS PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SS PIPING DURING NEW

WORK.

6. LIMIT OF DEMOLITION. CUT EXISTING SD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SD PIPING DURING NEW

WORK.

7. LIMIT OF DEMOLITION. CUT EXISTING OD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW OD PIPING DURING NEW

WORK.

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

(E) 3/4" MV

(E) 1/2" MA

(E) 1/2" OX

(E) 3/4" CA

(E) 3/4" MV (E) 1/2" MA

(E) 1/2" OX

2 4

3 2

1 1 1

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

2 4

34 4

STAFF TOILET

WOMEN'S

HEALTH TOILET

1245A

EXAM/

CONSULT

PACT

WORKROOM

BREAKOUT

WORKROOM

1201D

BREAKOUT

WORKROOM

1201E

PACT

WORKROOM

1202D

COMM

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

CONSULT

CONSULT

H .A

.C

PATIENT

TOILET

1208A

CONSULT

CONSULT

SUB-WAIT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1216A

PACT TEAMLET

AREA B3

C O

R R

ID

O

R

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

STAFF TOILET

W O

M E

N 'S

H E

A L

T H

T O

IL

E

T

A

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1234A

PACT TEAMLET

AREA B2

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

C O

R R

ID

O

R

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PACT TEAMLET

AREA B1

PATIENT

TOILET

1248A

STAFF TOILET

1201C

STAFF TOILET

1201B

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

PATIENT

CIRCULATION

STAFF

CIRCULATION

1290B

STAFF TOILET

W O

M E

N 'S

H E

A L

T H

T O

IL

E

T

A

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-102

FIRST FLOOR PRESSURE PIPING

DEMOLITION PLAN - AREA B

SCALE: 1/8" = 1'-0"

FIRST FLOOR PRESSURE PIPING

DEMOLITION PIPING PLAN - AREA B

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

1. EXISTING PLUMBING PIPING ABOVE CEILING TO REMAIN.

2. LIMIT OF DEMOLITION. CUT AND CAP EXISTING DOMESTIC

COLD WATER PIPING AT APPROXIMATE LOCATION INDICATED.

3. LIMIT OF DEMOLITION. CUT AND CAP EXISTING DOMESTIC HOT

WATER PIPING AT APPROXIMATE LOCATION INDICATED.

4. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

A. ALL EXISTING PLUMBING FIXTURES AND ALL ASSOCIATED

PIPING SERVING FIRST FLOOR TO REMAIN.

B. DEMOLITION SHALL INCLUDE ALL PIPE, FITTINGS, VALVES,

PIPE SUPPORTS, AND HANGERS OF PIPING BEING REMOVED.

C. ABANDONED OR UNUSED PIPING AND/OR RISERS SHALL BE

REMOVED.

D. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

E. DOMESTIC HOT AND COLD WATER PIPING SERVE BOTH

FIRST AND SECOND FLOOR PLUMBING FIXTURES.

CONTRACTOR SHALL COORDINATE ALL SERVICE

INTERUPTIONS WITH COR.

F. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

(E) 3/4" MV

(E) 1/2" MA

(E) 1/2" OX

(E) 3/4" CA

(E) 3/4" MV (E) 1/2" MA

(E) 1/2" OX

2 4

3 2

1 1 1

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

STAFF TOILET

WOMEN'S

HEALTH TOILET

1245A

EXAM/

CONSULT

PACT

WORKROOM

BREAKOUT

WORKROOM

1201D

BREAKOUT

WORKROOM

1201E

PACT

WORKROOM

1202D

COMM

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

CONSULT

CONSULT

H .A

.C

PATIENT

TOILET

1208A

CONSULT

CONSULT

SUB-WAIT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1216A

PACT TEAMLET

AREA B3

C O

R R

ID

O

R

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

STAFF TOILET

W O

M E

N 'S

H E

A L

T H

T O

IL

E

T

A

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PATIENT

TOILET

1234A

PACT TEAMLET

AREA B2

EXAM/

CONSULT

1226EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

C O

R R

ID

O

R

CLEAN SUPPLY

UTILITY

WOMEN'S

HEALTH

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

EXAM/

CONSULT

PACT TEAMLET

AREA B1

PATIENT

TOILET

1248A

STAFF TOILET

1201C

STAFF TOILET

1201B

STAFF BREAK

ROOM

SHARED

MEDICAL

APPOINTMENT

PATIENT

CIRCULATION

STAFF

CIRCULATION

1290B

STAFF TOILET

W O

M E

N 'S

H E

A L

T H

T O

IL

E

T

A

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\

D o c u m e n ts

\8

T u c s o n E x p a n d a n d R e n o C lin ic s

D E

D U

C T

P

M a ri o n

.V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-102A

FIRST FLOOR PRESSURE PIPING

DEMOLITION PLAN - AREA B - ALT. #1

SCALE: 1/8" = 1'-0"

FIRST FLOOR PRESSURE PIPING

DEMOLITION PIPING PLAN - AREA B -

ALT. #1

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

1. EXISTING PLUMBING PIPING ABOVE CEILING TO REMAIN.

2. LIMIT OF DEMOLITION. CUT AND CAP EXISTING DOMESTIC

COLD WATER PIPING AT APPROXIMATE LOCATION INDICATED.

3. LIMIT OF DEMOLITION. CUT AND CAP EXISTING DOMESTIC HOT

WATER PIPING AT APPROXIMATE LOCATION INDICATED.

4. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

A. ALL EXISTING PLUMBING FIXTURES AND ALL ASSOCIATED

PIPING SERVING FIRST FLOOR TO REMAIN.

B. DEMOLITION SHALL INCLUDE ALL PIPE, FITTINGS, VALVES,

PIPE SUPPORTS, AND HANGERS OF PIPING BEING REMOVED.

C. ABANDONED OR UNUSED PIPING AND/OR RISERS SHALL BE

REMOVED.

D. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

E. DOMESTIC HOT AND COLD WATER PIPING SERVE BOTH

FIRST AND SECOND FLOOR PLUMBING FIXTURES.

CONTRACTOR SHALL COORDINATE ALL SERVICE

INTERUPTIONS WITH COR.

F. ALL WORK ON FIRST FLOOR SHALL BE DONE AFTER HOURS.

MATCH LINE A

MATCH LINE A

M .G

FEC

FEC

FEC

FEC

FEC

FEC

DN

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

5 5

7 9

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

(E) 4" OD

(E) 4" SD

(E

3" V

(E) 4" OD

(E) 4" SD

(E) 4" OD(E) 4" OD

(D) 2" V (D) 2" V

(D

3" V

(D

6" S

D

(D

3" V

(E

6" O

D (E

6"

O D

(E

6" O

D

(E) 2" V(E) 2" V

(E

2" V

(E

2" V

(D) 2" V

(D

2" V

(D) 1 1/2" V (D) 1 1/2" V

(D

3" V

(D) 2" V

(D

2" V

(D) 1 1/2" V

(E

2" V

(E

6" O

D

(D

1/

2" V

(D

2" V

(D

2" V

(D

2" V

(D

2" V

(D

1/

2" S

S (D

1/ 2"

S S

(D) 1 1/2" SS

(D

2" V

(D

2" V

(D) 1 1/2" V

COMP OFFICE

W TLT

WAITING

M TLT

VEST

EXAM

CORR

EXAM

EXAM

EXAM

ALC

EXAM

NURSE

RECEPTION

CORR

EXAM

EXAM

EXAM

RN EXAM

RN EXAM

CORR

EXAM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

EQUIP STOR

CORR

CONFERENCE /

CLASSROOM

ST TLT

EXAM

EXAM

PT TLT

ISOL EXAM

EXAM

HAC

CORR

EXAM

TREATMENT

DIETITIAN

CONSULT

CORR

PHARM

CONSULT

PHARM

CONSULT

SW CONSULT

SW CONSULT

PHARM

CONSULT

NURSE

CLEAN SUPPLY

CORR

EXAM

EXAM

CORR

SOILED UTIL

2382 CORR

LOUNGE

PHARM

CONSULT

EXAM

CORR

CORR

M TLT

WAITING

RECEPTION

EXAM

EXAM

NURSE

EXAM

EXAM

RN EXAM

RN EXAM

PR OFFICE

CONFERENCE /

CLASSROOM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

CORR

PR OFFICE

PR OFFICE

CORR

EXT BALCONY

EXAM

EXAM

EXAM

ST TLT

EXAM

CORR

EXAM

PT TLT

ISOL EXAM

EXAM

2253EXAM

TREATMENT

DIETITION

CONSULT

CORR

CORR

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-103

SECOND FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B

SCALE: 1/8" = 1'-0"

SECOND FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

B. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

C. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN FLOORS

AND CEILINGS WHICH ARE DISCOVERED DURING DEMOLITION

BACK TO THE ORIGINAL BASE MATERIAL OR BETTER

COMPLYING WITH WATER TIGHT AND/OR FIRE RETARDANT

CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION ON THE FLOOR AND CEILING

REPAIR.

1. LIMITS OF DEMOLITION.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. REMOVE AND DISCARD EXISTING WATER CLOSET AND ALL

ASSOCIATED PIPING.

4. REMOVE AND DISCARD EXISTING WALL HUNG LAVATORY,

FIXTURE SUPPORT, TAILPIECE, TRAP. AND ALL ASSOCIATED

PIPING.

5. REMOVE AND DISCARD EXISTING SINK, TAILPIECE, TRAP. AND

ALL ASSOCIATED PIPING.

6. REMOVE AND DISCARD EXISTING DOUBLE COMPARTMENT

SINK, TAILPIECE, TRAP. AND ALL ASSOCIATED PIPING.

7. REMOVE AND DISCARD EXISTING CLINICAL SINK, FLUSH

VALVE, FAUCET, AND ALL ASSOCIATED PIPING.

8. REMOVE AND DISCARD EXISTING MOP BASIN, FAUCET, AND

ALL ASSOCIATED PIPING.

9. REMOVE AND DISCARD EXISTING BI-LEVEL ELECTRIC WATER

COOLER, AND ALL ASSOCIATED PIPING.

10. REMOVE AND DISCARD EXISTING FLOOR DRAIN, TRAP, AND

ALL ASSOCIATED PIPING.

11. LIMIT OF DEMOLITION. CUT AND PLUG EXISTING VENT PIPING

ABOVE CEILING AT APPROXIMATE LOCATION INDICATED.

PIPING SHALL BE CONNECTED TO VENT PIPING DURING NEW

WORK.

12. REMOVE AND DISCARD EXISTING URINAL, CARRIER, AND ALL

ASSOCIATED PIPING.

13. LIMIT OF DEMOLITION. CUT AND PLUG EXISTING VENT PIPING

ABOVE CEILING AT APPROXIMATE LOCATION INDICATED.

PIPING SHALL BE FOR FUTURE USE.

14. LIMIT OF DEMOLITION. CUT EXISTING OD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW OD PIPING DURING NEW

WORK.

15. LIMIT OF DEMOLITION. CUT EXISTING SD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SD PIPING DURING NEW

WORK.

16. REMOVE AND DISCARD EXISTING AREA DRAIN, TRAP, AND ALL

ASSOCIATED PIPING.

MATCH LINE A

M .G

FEC

FEC

FEC

FEC

FEC

FEC

DN

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

5 5

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

(E) 4" OD

(E) 4" SD

(E

3" V

(E) 4" OD

(E) 4" SD

(E) 4" OD(E) 4" OD

(E) 2" V (E) 2" V

(E

3" V

(D

6" S

D

(D

3" V

(E

6" O

D (E

6"

O D

(E

6" O

D

(E) 2" V(E) 2" V

(E

2" V

(E

2" V

(E) 2" V

(E

2" V

(E) 1 1/2" V (E) 1 1/2" V

(E

3" V

(D) 2" V

(D

2" V

(D) 1 1/2" V

(E

2" V

(E

6" O

D

(D

1/

2" V

(D

2" V

(D

2" V

(D

2" V

(D

2" V

(D

1/

2" S

S (D

1/ 2"

S S

(D) 1 1/2" SS

(D

2" V

(D

2" V

(D) 1 1/2" V

COMP OFFICE

W TLT

WAITING

M TLT

VEST

EXAM

CORR

EXAM

EXAM

EXAM

ALC

EXAM

NURSE

RECEPTION

CORR

EXAM

EXAM

EXAM

RN EXAM

RN EXAM

CORR

EXAM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

EQUIP STOR

CORR

CONFERENCE /

CLASSROOM

ST TLT

EXAM

EXAM

PT TLT

ISOL EXAM

EXAM

HAC

CORR

EXAM

TREATMENT

DIETITIAN

CONSULT

CORR

PHARM

CONSULT

PHARM

CONSULT

SW CONSULT

SW CONSULT

PHARM

CONSULT

NURSE

CLEAN SUPPLY

CORR

EXAM

EXAM

CORR

SOILED UTIL

CORR

LOUNGE

PHARM

CONSULT

EXAM

CORR

CORR

M TLT

WAITING

RECEPTION

EXAM

EXAM

NURSE

EXAM

EXAM

RN EXAM

RN EXAM

PR OFFICE

CONFERENCE /

CLASSROOM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

CORR

PR OFFICE

PR OFFICE

CORR

EXT BALCONY

EXAM

EXAM

EXAM

ST TLT

EXAM

CORR

EXAM

PT TLT

ISOL EXAM

EXAM

2253EXAM

TREATMENT

DIETITION

CONSULT

CORR

CORR

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\

D o c u m e n ts

\8

T u c s o n E x p a n d a n d R e n o C lin ic s

D E

D U

C T

P

M a ri o n

.V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-103A

SECOND FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B - ALT. #1

SCALE: 1/8" = 1'-0"

SECOND FLOOR GRAVITY PIPING

DEMOLITION PLAN - AREA B - ALT. #1

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

B. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

C. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN FLOORS

AND CEILINGS WHICH ARE DISCOVERED DURING DEMOLITION

BACK TO THE ORIGINAL BASE MATERIAL OR BETTER

COMPLYING WITH WATER TIGHT AND/OR FIRE RETARDANT

CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION ON THE FLOOR AND CEILING

REPAIR.

1. LIMITS OF DEMOLITION.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. REMOVE AND DISCARD EXISTING WATER CLOSET AND ALL

ASSOCIATED PIPING.

4. REMOVE AND DISCARD EXISTING WALL HUNG LAVATORY,

FIXTURE SUPPORT, TAILPIECE, TRAP. AND ALL ASSOCIATED

PIPING.

5. REMOVE AND DISCARD EXISTING SINK, TAILPIECE, TRAP. AND

ALL ASSOCIATED PIPING.

8. REMOVE AND DISCARD EXISTING MOP BASIN, FAUCET, AND

ALL ASSOCIATED PIPING.

9. REMOVE AND DISCARD EXISTING BI-LEVEL ELECTRIC WATER

COOLER, AND ALL ASSOCIATED PIPING.

10. REMOVE AND DISCARD EXISTING FLOOR DRAIN, TRAP, AND

ALL ASSOCIATED PIPING.

11. LIMIT OF DEMOLITION. CUT AND PLUG EXISTING VENT PIPING

ABOVE CEILING AT APPROXIMATE LOCATION INDICATED.

PIPING SHALL BE CONNECTED TO VENT PIPING DURING NEW

WORK.

12. REMOVE AND DISCARD EXISTING URINAL, CARRIER, AND ALL

ASSOCIATED PIPING.

13. LIMIT OF DEMOLITION. CUT AND PLUG EXISTING VENT PIPING

ABOVE CEILING AT APPROXIMATE LOCATION INDICATED.

PIPING SHALL BE FOR FUTURE USE.

14. LIMIT OF DEMOLITION. CUT EXISTING OD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW OD PIPING DURING NEW

WORK.

15. LIMIT OF DEMOLITION. CUT EXISTING SD PIPING ABOVE

CEILING AT APPROXIMATE LOCATION INDICATED. PIPING

SHALL BE CONNECTED TO NEW SD PIPING DURING NEW

WORK.

16. REMOVE AND DISCARD EXISTING AREA DRAIN, TRAP, AND ALL

MATCH LINE A

M .G

FEC

FEC

FEC

FEC

FEC

FEC

DN

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

3 4

4 5

7 9 9

(D) 1/2" OX

(D) 1/2" MA

(D) 3/4" MV

(D) 1/2" OX

(D) 1/2" MA

(D) 3/4" MV

(D) 1/2" OX

(D) 1/2" MA

(D) 3/4" MV

(D) 1/2" OX

(D) 1/2" MA

(D) 3/4" MV

(D

1/ 2"

O X

(D

1/ 2"

M A

(D

3/ 4"

M V

COMP OFFICE

W TLT

WAITING

M TLT

VEST

EXAM

CORR

EXAM

EXAM

EXAM

ALC

EXAM

NURSE

RECEPTION

CORR

EXAM

EXAM

EXAM

RN EXAM

RN EXAM

CORR

EXAM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

EQUIP STOR

CORR

CONFERENCE /

CLASSROOM

ST TLT

EXAM

EXAM

PT TLT

ISOL EXAM

EXAM

HAC

CORR

EXAM

TREATMENT

DIETITIAN

CONSULT

CORR

PHARM

CONSULT

PHARM

CONSULT

SW CONSULT

SW CONSULT

PHARM

CONSULT

NURSE

CLEAN SUPPLY

CORR

EXAM

EXAM

CORR

SOILED UTIL

CORR

LOUNGE

PHARM

CONSULT

EXAM

CORR

CORR

M TLT

WAITING

RECEPTION

EXAM

EXAM

NURSE

EXAM

EXAM

RN EXAM

RN EXAM

PR OFFICE

CONFERENCE /

CLASSROOM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

CORR

PR OFFICE

PR OFFICE

CORR

EXT BALCONY

EXAM

EXAM

EXAM

2233ST TLT

EXAM

CORR

EXAM

PT TLT

ISOL EXAM

EXAM

EXAM

TREATMENT

DIETITION

CONSULT

CORR

CORR

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-104

SECOND FLOOR PRESSURE PIPING

DEMOLITION PLAN - AREA B

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

B. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

C. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN FLOORS

AND CEILINGS WHICH ARE DISCOVERED DURING DEMOLITION

BACK TO THE ORIGINAL BASE MATERIAL OR BETTER

COMPLYING WITH WATER TIGHT AND/OR FIRE RETARDANT

CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION ON THE FLOOR AND CEILING

REPAIR.

D. DOMESTIC HOT AND COLD WATER PIPING FEED FIXTURES

FROM BELOW. REFER TO PLUMBING DRAING 80-PD102.

SCALE: 1/8" = 1'-0"

SECOND FLOOR PRESSURE PIPING

DEMOLITION PLAN - AREA B

1. EXISTING PLUMBING PIPING ABOVE CEILING TO REMAIN.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. REMOVE AND DISCARD EXISTING WATER CLOSET AND ALL

ASSOCIATED PIPING.

4. REMOVE AND DISCARD EXISTING WALL HUNG LAVATORY,

FIXTURE SUPPORT AND ALL ASSOCIATED PIPING.

5. REMOVE AND DISCARD EXISTING SINK AND ALL ASSOCIATED

PIPING.

6. REMOVE AND DISCARD EXISTING DOUBLE COMPARTMENT

SINK AND ALL ASSOCIATED PIPING.

7. REMOVE AND DISCARD EXISTING CLINICAL SINK, FLUSH

VALVE, FAUCET, AND ALL ASSOCIATED PIPING.

8. REMOVE AND DISCARD EXISTING MOP BASIN, FAUCET, AND

ALL ASSOCIATED PIPING.

9. REMOVE AND DISCARD EXISTING BI-LEVEL ELECTRIC WATER

COOLER, AND ALL ASSOCIATED PIPING.

10. REMOVE AND DISCARD EXISTING URINAL, FIXTURE SUPPORT,

FLUSH VALVE, AND ALL ASSOCIATED PIPING.

11. LIMIT OF DEMOLITION. CUT AND PLUG EXISTING MEDICAL AIR,

OXYGEN, AND MEDICAL VACUUM PIPING AT VALVE BOX.

12. REMOVE AND DISCARD EXISTING HOSE BIB AND ALL

MATCH LINE A

M .G

FEC

FEC

FEC

FEC

FEC

FEC

DN

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

3 4

4 5

(E) 1/2" OX

(E) 1/2" MA

(E) 3/4" MV

(E) 1/2" OX

(E) 1/2" MA

(E) 3/4" MV

(E) 1/2" OX

(E) 1/2" MA

(E) 3/4" MV

(E) 1/2" OX

(E) 1/2" MA

(E) 3/4" MV

(D

1/ 2"

O X

(D

1/ 2"

M A

(D

3/ 4"

M V

COMP OFFICE

W TLT

WAITING

M TLT

VEST

EXAM

CORR

EXAM

EXAM

EXAM

ALC

EXAM

NURSE

RECEPTION

CORR

EXAM

EXAM

EXAM

RN EXAM

RN EXAM

CORR

EXAM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

EQUIP STOR

CORR

CONFERENCE /

CLASSROOM

ST TLT

EXAM

EXAM

PT TLT

ISOL EXAM

EXAM

HAC

CORR

EXAM

TREATMENT

DIETITIAN

CONSULT

CORR

PHARM

CONSULT

PHARM

CONSULT

SW CONSULT

SW CONSULT

PHARM

CONSULT

NURSE

CLEAN SUPPLY

CORR

EXAM

EXAM

CORR

SOILED UTIL

CORR

LOUNGE

PHARM

CONSULT

EXAM

CORR

CORR

M TLT

WAITING

RECEPTION

EXAM

EXAM

NURSE

EXAM

EXAM

RN EXAM

RN EXAM

PR OFFICE

2236CONFERENCE /

CLASSROOM

PR OFFICE

PR OFFICE

PR OFFICE

PR OFFICE

CORR

PR OFFICE

PR OFFICE

CORR

EXT BALCONY

EXAM

EXAM

EXAM

2233ST TLT

EXAM

CORR

EXAM

PT TLT

ISOL EXAM

EXAM

EXAM

TREATMENT

DIETITION

CONSULT

CORR

CORR

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\

D o c u m e n ts

\8

T u c s o n E x p a n d a n d R e n o C lin ic s

D E

D U

C T

P

M a ri o n

.V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PD-104A

SECOND FLOOR PRESSURE PIPING

DEMOLITION PLAN - AREA B - ALT. #1

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

DEMO KEY NOTES#

GENERAL NOTES

A. DEMOLITION SHALL INCLUDE, PIPING, FITTINGS, PIPE

SUPPORTS,AND HANGERS OF PIPING BEING REMOVED.

B. ABANDONED OR UNUSED PIPING, FITTINGS, SUPPORTS, AND

HANGERS ABOVE CEILING SHALL BE REMOVED.

C. CONTRACTOR SHALL RESTORE ALL PENETRATIONS, HOLES,

VOIDS, HOLLOWS, DEPRESSIONS, DIPS, DENTS, INDENTS,

CAVITIES, CONCAVITIES, PITS, TROUGHS, DIMPLES, CLEFTS,

NICKS, NOTCHES, GROOVES, IMPRESSIONS, IMPRINTS,

MARKS, RECESSES, BAYS, INLETS, AND ANY COVES IN FLOORS

AND CEILINGS WHICH ARE DISCOVERED DURING DEMOLITION

BACK TO THE ORIGINAL BASE MATERIAL OR BETTER

COMPLYING WITH WATER TIGHT AND/OR FIRE RETARDANT

CONDITIONS. REFER TO ARCHITECTURAL DRAWINGS FOR

ADDITIONAL INFORMATION ON THE FLOOR AND CEILING

REPAIR.

D. DOMESTIC HOT AND COLD WATER PIPING FEED FIXTURES

FROM BELOW. REFER TO PLUMBING DRAING 80-PD102.

SCALE: 1/8" = 1'-0"

SECOND FLOOR PRESSURE PIPING

DEMOLITION PIPING PLAN - AREA B -

ALT. #1

1. EXISTING PLUMBING PIPING ABOVE CEILING TO REMAIN.

2. REMOVE AND DISCARD EXISTING PLUMBING PIPING BACK TO

LIMITS OF DEMOLITION.

3. REMOVE AND DISCARD EXISTING WATER CLOSET AND ALL

ASSOCIATED PIPING.

4. REMOVE AND DISCARD EXISTING WALL HUNG LAVATORY,

FIXTURE SUPPORT AND ALL ASSOCIATED PIPING.

5. REMOVE AND DISCARD EXISTING SINK AND ALL ASSOCIATED

PIPING.

8. REMOVE AND DISCARD EXISTING MOP BASIN, FAUCET, AND

ALL ASSOCIATED PIPING.

9. REMOVE AND DISCARD EXISTING BI-LEVEL ELECTRIC WATER

COOLER, AND ALL ASSOCIATED PIPING.

10. REMOVE AND DISCARD EXISTING URINAL, FIXTURE SUPPORT,

FLUSH VALVE, AND ALL ASSOCIATED PIPING.

11. REMOVE AND DISCARD EXISTING MEDICAL GAS AND VACUUM

PIPING, FITTINGS, AND HANGERS BACK TO LIMITS OF

DEMOLITION. CAP PIPING AT LIMITS OF DEMOLITION.

12. REMOVE AND DISCARD EXISTING HOSE BIB AND ALL

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

6" S

S

2" SS

4" SS

4" SS

4" SS

4" SS

2" SS

6" S

S 6"

S S

2" SS 8"

S

D

4" SD

6" S

D

6" SD

4" S

D

4" SD

10-42" BFF -48" BFF

10,376 SQFT

324 GPM

-24" BFF

3" SD

3" SD

3" SD

6" S

D 4"

S D

9.69.08.28.07.57.37.17.0

M

L.8

L

K.8

K

J.8

J.5

I

H.8

H.7

H.6

M.8

H.6A

3" S

D 8"

S D

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PL-101

FOUNDATION PIPING PLAN - AREA A

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

GENERAL NOTES

# KEY NOTES

A. COORDINATE PIPE ROUTING WITH DUCT ROUTING,

EQUIPMENT LOCATIONS, ELECTRICAL INSTALLATIONS, AND

BUILDING STRUCTURAL MEMBERS. OFFSET PIPING WHERE

REQUIRED TO AVOID CONFLICTS. AVOID PENETRATING ANY

MAIN STRUCTURAL BEAM. NOTIFY COR AND ARCHITECT OF

ANY CONFLICTS.

B. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL

PLUMBING CODE, LOCAL CODE, AND/OR WHERE HORIZONTAL

SANITARY SEWER PIPING CHANGES DIRECTION OVER 45

DEGREES.

C. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A

MINIMUM OF TWO PERCENT, ONE-QUARTER INCH PER FOOT.

NEW 3" AND 4" SANITARY SEWER PIPING SHALL BE SLOPED A

MINIMUM OF ONE PERCENT, ONE-EIGHTH INCH PER FOOT.

SCALE: 1/8" = 1'-0"

FOUNDATION PIPING PLAN - AREA A

1. 2"SS-UP.

2. 4"SS-UP.

3. 4"SS-UP TO CLEANOUT.

4. 4"SS-UP TO OUTSIDE CLEANOUT.

5. 3"SD-UP TO CANOPY STORM WATER.

6. 4"SD-UP.

7. 4"SD-UP TO CLEANOUT.

8. 4"SD-UP TO OUTSIDE CLEANOUT.

9. 6"SD-UP.

10. REFER TO CIVIL DRAWINGS FOR CONTINUATION OF PIPING.

11. TWO-WAY CLEANOUT TEE

12. SEE PIPE AND FOOTER DETAIL ON SHEET 80-P-001.

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

9.69.08.28.07.57.37.17.0

I

H.8

H.7

H.6

H.4

H

G.5

G

F.5

F.2

F

E.5

E.2

E

H.6A

3" S

D 3"

S D

4 4

4" S

S

24" BFF

(E

6" S

D

(E) 2" SS(E) 2" SS

(E) 4" SS

(E) 4" SS

(E) 8" SD

(E) 2" SS

(E) 2 1/2" SS

(E) 2" SS

(E

2" S

S

(E

2" S

S (E

2"

S S

(E) 2 1/2" SS

(E

2" S

S

(E) 2 1/2" SS

(E) 2" SS

(E) 8" SD

(E) 4" SS

(E

4" S

S

(E) 4" SS

(E) 4" SS

(E

4" S

S

(E) 4" SS

(E

3" S

S

(E

4" S

S

(E) 4" SS

(E

6" S

D

(E

3" S

S

(E) 4" SS

(E

3" S

S (E

3"

S S

(E

1/

2" S

S (E

2"

S S

(E

2" S

S

(E) 2" SS

(E) 2" SS

(E) 2" SS

(E) 4" SS

(E) 2" SS

(E

4" S

S

(E) 2" SS

(E) 2" SS

(E) 4" SS

(E) 2" SS

(E) 2" SS

(E) 4" SS

(E) 2" SS

(E) 2" SS

(E) 4" SS

(E) 4" SS(E) 4" SS

(E) 4" SS

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r i o n .V a n

T ru m p

II

I.

rv t

EXPAND - RENOVATE CLINICS

B80

TUCSON, AZ

FEBRUARY 15, 2022 WAW GTK

678-328

80-PL-102

FOUNDATION PIPING PLAN - AREA B

1/8" = 1' - 0" 0 8' 16'4'

GRAPHIC SCALE(S)

KEY PLAN

GENERAL NOTES

# KEY NOTES

A. COORDINATE PIPE ROUTING WITH DUCT ROUTING,

EQUIPMENT LOCATIONS, ELECTRICAL INSTALLATIONS, AND

BUILDING STRUCTURAL MEMBERS. OFFSET PIPING WHERE

REQUIRED TO AVOID CONFLICTS. AVOID PENETRATING ANY

MAIN STRUCTURAL BEAM. NOTIFY COR AND ARCHITECT OF

ANY CONFLICTS.

B. PROVIDE CLEANOUT(S) AS REQUIRED BY INTERNATIONAL

PLUMBING CODE, LOCAL CODE, AND/OR WHERE HORIZONTAL

SANITARY SEWER PIPING CHANGES DIRECTION OVER 45

DEGREES.

C. NEW 2" SANITARY SEWER PIPING SHALL BE SLOPED A

MINIMUM OF TWO PERCENT, ONE-QUARTER INCH PER FOOT.

NEW 3" AND 4" SANITARY SEWER PIPING SHALL BE SLOPED A

MINIMUM OF ONE PERCENT, ONE-EIGHTH INCH PER FOOT.

SCALE: 1/8" = 1'-0"

FOUNDATION PIPING PLAN - AREA B

1. 4"SS-UP.

2. 3"SD-UP.

3. 3"SD-UP TO CLEANOUT.

4. CONNECT NEW SANITARY SEWER PIPING TO EXISTING

SANITARY SEWER PIPING BELOW FLOOR AT THE

APPROXIMATE LOCATION INDICATED.

AREA

A

BLDG

AREA

B

PLAN

NORTH

TRUE

NORTH

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

MATCH LINE AMATCH LINE A

MATCH LINE BMATCH LINE B

4" OD

4" SD

4" O

D

6" SD

4" OD

4" S

D

6" O

D

CO

CO

YCO YCO

2" SS

2" S

S

4" S

S

2" SS

2" S

S 2"

S S

2" S

S

4" S

S

4" SS

2" S

S

CO

CO

CO

CO

4 4

4,595 SQFT

144 GPM

9.69.08.28.07.57.37.17.0

M

L.8

L

K.8

K

J.8

J.5

I

H.8

H.7

H.6

M.8

H.6A

4,706 SQFT

147 GPM

6" O

D

6" O

D

4" O

D

6" O

D

4" O

D

4" O

D

4" OD

4" SD

4" SD

CO

4" SS4" SS

CO

2" S

S

2" SS

CO

CO

2" S

S

CO

4" S

S

2" S

S

CO

2" S

S 2"

S S

2" S

S

4" SD

CO

4"

S S

4" S

S

(E

3" S

D (E

3"

O D

(E

3" O

D

(E) 3" SD

(E) 3" SD

(E

3" O

D

8 8

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

WCO

CLEAN SUPPLY

PATIENT

CIRCULATION

EXAM /

CONSULT

EXAM /

CONSULT

EXAM /

CONSULT

EXAM /

CONSULT

WOMEN'S

HEALTH

WOMEN'S

HEALTH TOILET

1325A

STAFF TOILET

EXAM /

CONSULT

EXAM /

CONSULT

CLEAN SUPPLY

UTILITY

ELECTRICAL

TELERETINAL

VOLUNTEERS

MECHANICAL

ELECTRICAL

ALCOVE

1301A

VESTIBULE

STAIR

PATIENT

CIRCULATION

CHECK-IN

ALCOVE

ELEVATOR

80-P3

ELEVATOR

80-P4

ELEVATOR

LOBBY

FAMILY TOILET

FAMILY TOILET

FAMILY TOILET

FAMILY TOILET

CONSULT

CONSULT

PACT TEAMLET

AREA A2

C O

R R

ID

O

R

PACT TEAMLET

AREA A1

C O

R R

ID

O

R

EXAM /

CONSULT

EXAM /

CONSULT

EXAM /

CONSULT

ELECTRICAL

PATIENT

TOILET

SHARED

MEDICAL

APPOINTMENT

STAFF BREAK

ROOM

PACT

WORKROOM

BREAKOUT

WORKROOM

PACT

WORKROOM

STAFF TOILET

PATIENT

TOILET

DATA ROOM

C O

R R

ID

O

R

YCO

YCO YCO

STRUCTURAL ENGINEER

INNOVATIVE ENGINEERING

3380 TRICKUM ROAD

SUITE 500

WOODSTOCK, GA 30188

770.517.5507

CIVIL ENGINEER

PSOMAS

333 E. WETMORE ROAD

SUITE 450

TUCSON, AZ 85705-5256

MEP ENGINEER

CLARK NEXSEN

440 MARTIN LUTHER KING JR BLVD

SUITE 101

MACON, GA 31201

478.743.8415

Drawing Number

Project Number

Date

OF

Project Title

Building Number

Location

Checked Drawn

APPROVED: CHIEF, FACILITIES MANAGEMENT

Drawing Title

Revisions Date o n e -e ig h th in ch o n e f o o t o n e -q u a rt e r in ch o n e f o o t th re e

-e ig h th s in ch o n e f o o t o n e -h a lf in ch o n e f o o t th re e -q u a rt e rs in ch o n e f o o t o n e in ch o n e f o o t o n e a n d o n e

-h a lf in ch e s o n e f o o t th re e in ch e s o n e f o o t

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

B

A

C

D

E

FF

E

D

C

A

B

VA FORM 08-6231

Dwg.

ARCHITECT/ENGINEERS:

APPROVED: DIRECTOR

APPROVED: ASSOCIATE DIRECTOR

APPROVED: ASSISTANT DIRECTOR APPROVED: CHIEF OF STAFF

APPROVED: ASSOCIATE DIRECTOR PATIENT SERVICES

590 MEANS STREET NW

STE. 200

ATLANTA, GA 30318

CONSULTANTS:

Office of

Construction and Facilities Management

U.S. Department of Veterans Affairs

BID DOCUMENTS

C

U s e rs \M a ri o n .V a n

T ru m p

II

I\ D o c u m e n ts

\8

T u c s o n E x p a n d a n d

R e n o C lin ic s P

M a r…

This is the start of the file's text. The full file is on GovTribe.