ParkerSt RRFB_MA83ft-24x36.pdf

PDF 181 KB Posted

Attached to
Pedestrian Improvement Project
Solicitation number
BD-17-1640-TOM00-TOM01-23274
Issued by
Middlesex County, Massachusetts

About this file

The provided document is a project plan for a Pedestrian Improvement Project at the intersection of Parker Street and Harrison Street in Maynard, Massachusetts. The project will involve the installation of Rectangular Rapid Flashing Beacons (RRFBs), unclassified excavation, cement concrete sidewalks, tree trimming, installation of traffic signs, and other incidental work. The project is being managed by the state of Massachusetts, specifically in Middlesex County. The document outlines the required materials and equipment, including P-5 posts, solar panels, radio antennas, pedestrian push buttons, and various signage. Construction notes indicate the contractor will need to coordinate with the local Department of Public Works for any alternate RRFB foundation locations due to potential underground utility conflicts.

The document does not provide details on pricing terms, set asides, incumbents, funding requirements, or sources. It also does not mention any response dates, due dates, site visits, bidder's meetings, award dates, or contract term information.

View the file

Other files

File Type Posted
Information for Bidders~1.pdf PDF
Prevailing Wage Rates~1.pdf PDF
Invitation for Bids~1.pdf PDF
Maynard RRFB Spec - Revised.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HARRISON STREET

PA

R K

ER

S

TR

EE

T

PROP P-5 POST

W/2 RRFB UNITS

W/SOLAR PANEL

W/RADIO ANTENNA

W/PED PUSH BUTTON

W/R10-25

PROP P-5 POST

W/2 RRFB UNITS

W/SOLAR PANEL

W/RADIO ANTENNA

W/PED PUSH BUTTON

W/R10-25

W/W11-2

W/W11-2

W/W16-7pL

W/W16-7pR

R&S

R&S

POST LOCATION TO

BE FIELD LOCATED WITH

TOWN PUBLIC WORKS

RET

PROP W11-2

R&S

RET

AS NEEDED

W/R10-SP

REPLACE CEM CONC PANEL

W/R10-SP

PROP P-5 POST

W/1 RRFB UNITS

W/SOLAR PANEL

W/RADIO ANTENNA

W/W11-2

W/W16-9p

SCALE IN FEET

20 40

W16-7p(L) SIGN, 24"x12"

R10-25, 9"x12"

MTD FACING CURB OPENING

RRFB

SOLAR PANEL

W11-2 SIGN, 30"x30"

P-5 POST

7.0' MIN

FINISH GRADE

SCALE: N.T.S.

RECTANGULAR RAPID FLASHING

BEACON (RRFB) - POST MOUNTED

PEDESTRIAN PUSH BUTTON

RADIO ANTENNA

LIST OF MAJOR ITEMS REQUIRED

PEDESTRIAN HYBRID BEACON.

824.401

PEDESTRIAN PUSH BUTTON W/R10-25

EQUIPMENT TO COMPLETE THE INSTALLATION AND PROVIDE AN OPERATING

PLUS NECESSARY DUCT, CABLE, LABOR, MISCELLANEOUS MATERIAL AND

L.E.D. RECTANGULAR RAPID FLASHING BEACON (RRFB)

P-5 POST STANDARD INCL. FOUNDATION

DESCRIPTION

QUANTITYPAY ITEM

PARKER STREET AT HARRISON STREET

SOLAR PANEL

RADIO ANTENNA

W16-7p(R) SIGN, 24"x12"

RRFB

SOLAR PANEL

W11-2 SIGN, 30"x30"

P-5 POST

7.0' MIN

FINISH GRADE

RADIO ANTENNA

R10-SP, 9"x12"

MTD FACING CURB OPENING

OPERATIONAL NOTES:

1. RRFBS SHALL WIG-WAG FLASH WHEN ACTIVATED BY PEDESTRIAN PUSH BUTTON.

2. DURATION OF RRFB UPON RECEIPT OF VALID PEDESTRIAN PUSH BUTTON

ACTUATION SHALL BE INITIALLY SET FOR 10 SECONDS.

3. THE SYSTEM SHALL BE CAPABLE OF PROVIDING A FLASHING RATE OF 70 TO 80

CYCLES PER MINUTE.

4. SEE SPECIAL PROVISIONS, ITEM 824.401, FOR MORE DETAILS.

CONSTRUCTION NOTES:

1. CONTRACTOR TO COORDINATE WITH DPW DURING CONSTRUCTION FOR

ALTERNATE LOCATION, IF UNDERGROUND UTILITIES PREVENT INSTALLATION AT

THE PROPOSED LOCATION OF RRFB FOUNDATIONS.

File details come from the government source that posted it. Updated .