ParkerSt RRFB_MA83ft-24x36.pdf
PDF 181 KB Posted
- Attached to
- Pedestrian Improvement Project
- Solicitation number
- BD-17-1640-TOM00-TOM01-23274
- Issued by
- Middlesex County, Massachusetts
About this file
The provided document is a project plan for a Pedestrian Improvement Project at the intersection of Parker Street and Harrison Street in Maynard, Massachusetts. The project will involve the installation of Rectangular Rapid Flashing Beacons (RRFBs), unclassified excavation, cement concrete sidewalks, tree trimming, installation of traffic signs, and other incidental work. The project is being managed by the state of Massachusetts, specifically in Middlesex County. The document outlines the required materials and equipment, including P-5 posts, solar panels, radio antennas, pedestrian push buttons, and various signage. Construction notes indicate the contractor will need to coordinate with the local Department of Public Works for any alternate RRFB foundation locations due to potential underground utility conflicts.
The document does not provide details on pricing terms, set asides, incumbents, funding requirements, or sources. It also does not mention any response dates, due dates, site visits, bidder's meetings, award dates, or contract term information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Information for Bidders~1.pdf | ||
| Prevailing Wage Rates~1.pdf | ||
| Invitation for Bids~1.pdf | ||
| Maynard RRFB Spec - Revised.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HARRISON STREET
PA
R K
ER
S
TR
EE
T
PROP P-5 POST
W/2 RRFB UNITS
W/SOLAR PANEL
W/RADIO ANTENNA
W/PED PUSH BUTTON
W/R10-25
PROP P-5 POST
W/2 RRFB UNITS
W/SOLAR PANEL
W/RADIO ANTENNA
W/PED PUSH BUTTON
W/R10-25
W/W11-2
W/W11-2
W/W16-7pL
W/W16-7pR
R&S
R&S
POST LOCATION TO
BE FIELD LOCATED WITH
TOWN PUBLIC WORKS
RET
PROP W11-2
R&S
RET
AS NEEDED
W/R10-SP
REPLACE CEM CONC PANEL
W/R10-SP
PROP P-5 POST
W/1 RRFB UNITS
W/SOLAR PANEL
W/RADIO ANTENNA
W/W11-2
W/W16-9p
SCALE IN FEET
20 40
W16-7p(L) SIGN, 24"x12"
R10-25, 9"x12"
MTD FACING CURB OPENING
RRFB
SOLAR PANEL
W11-2 SIGN, 30"x30"
P-5 POST
7.0' MIN
FINISH GRADE
SCALE: N.T.S.
RECTANGULAR RAPID FLASHING
BEACON (RRFB) - POST MOUNTED
PEDESTRIAN PUSH BUTTON
RADIO ANTENNA
LIST OF MAJOR ITEMS REQUIRED
PEDESTRIAN HYBRID BEACON.
824.401
PEDESTRIAN PUSH BUTTON W/R10-25
EQUIPMENT TO COMPLETE THE INSTALLATION AND PROVIDE AN OPERATING
PLUS NECESSARY DUCT, CABLE, LABOR, MISCELLANEOUS MATERIAL AND
L.E.D. RECTANGULAR RAPID FLASHING BEACON (RRFB)
P-5 POST STANDARD INCL. FOUNDATION
DESCRIPTION
QUANTITYPAY ITEM
PARKER STREET AT HARRISON STREET
SOLAR PANEL
RADIO ANTENNA
W16-7p(R) SIGN, 24"x12"
RRFB
SOLAR PANEL
W11-2 SIGN, 30"x30"
P-5 POST
7.0' MIN
FINISH GRADE
RADIO ANTENNA
R10-SP, 9"x12"
MTD FACING CURB OPENING
OPERATIONAL NOTES:
1. RRFBS SHALL WIG-WAG FLASH WHEN ACTIVATED BY PEDESTRIAN PUSH BUTTON.
2. DURATION OF RRFB UPON RECEIPT OF VALID PEDESTRIAN PUSH BUTTON
ACTUATION SHALL BE INITIALLY SET FOR 10 SECONDS.
3. THE SYSTEM SHALL BE CAPABLE OF PROVIDING A FLASHING RATE OF 70 TO 80
CYCLES PER MINUTE.
4. SEE SPECIAL PROVISIONS, ITEM 824.401, FOR MORE DETAILS.
CONSTRUCTION NOTES:
1. CONTRACTOR TO COORDINATE WITH DPW DURING CONSTRUCTION FOR
ALTERNATE LOCATION, IF UNDERGROUND UTILITIES PREVENT INSTALLATION AT
THE PROPOSED LOCATION OF RRFB FOUNDATIONS.