Paging - Building Diagrams.pdf
PDF 360 KB Posted
- Attached to
- Paging System
- Solicitation number
- RFP - MEM - 240000001319
- Issued by
- Macomb County, Menominee City, Michigan
About this file
This document contains building diagrams for the paging system upgrade at the Memphis Community Schools, including the elementary school and junior/senior high school. The project covers the replacement of existing in-wall speakers with new horns and strobes, as well as the installation of additional speakers and horns throughout the facilities. The project is located in Macomb County and Menominee City, Michigan. The bidding is scheduled for January 19, 2024, with a rebid on February 19, 2024. The document provides detailed keynotes and a symbol legend for the paging system components, including wattages and mounting heights.
Regarding pricing and other details, the document does not provide information on pricing terms, set asides, incumbents, funding requirements, or other salient commercial details. The focus of this document is on the technical specifications and layout of the paging system upgrade.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Memphis Schools Critcal Communitions Paging System 2-19.pdf | ||
| Paging System Rebid - Addendum 1.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOM 38
ROOM 39
ROOM 40
ROOM 41
ROOM 42
IDF 1
ROOM 37
STAGE
ROOM 43 ROOM 50
ROOM 35
ROOM 49
ROOM 48
ROOM 47ROOM 46
ROOM 45
ROOM 44
ROOM 33
UPPER CAFETERIA
KITCHEN
ROOM 51 ROOM 52 ROOM 53 ROOM 54
MUSIC
ROOM 30
ROOM 32
ROOM 31
ROOM 29
GYMNASIUM
BOILER
ROOM MDF
ROOM 28
RCVG
ROOM 25 ROOM 22
ROOM 26 ROOM 21
ROOM 20
ROOM 23
MEDIA CTR
ROOM 24
LIBRARY
ROOM 13 ROOM 12
ROOM 14 ROOM 11
ROOM 15 ROOM 10
ROOM 01
DAYCARE
ROOM 09
BABY RM
ROOM 02
DAYCARE
ROOM 08
TODDLER
ROOM 03 ROOM 07
ROOM 04 ROOM 05
ROOM 06
ROOM 16ROOM 17
WORK RM
ROOM 18
LOUNGE
ROOM 19
OFFICE
RESTROOM
RESTROOM
RESTROOMS RESTROOMS
RESTROOMS
RESTROOMS
0' 5' 10' 20' 30' 40' 50'
NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S S S S
S S S S
S
S
S
S
S
S
S
S
S
S
S
S S
S
S
S S S S S S
S S S
S
S S
S
S
S
S
S
S
S S
S S
S S
S S
S
S
S S
S
S S S
S
S 15W
S 15W
S 15W
S
15W
S 15W
S
15W
S 15W
S 15W
7.5W
S
15W
S
S S S
S S S
S
7.5W 7.5W
15W
15W
15W
15W
15W
15W
S
S
S
S
S
S
S
S
S
S
S S S
S
S
15W
S 15W
EXISTING EMPTY EMT
TO NEW HORN LOCATION
(TYPICAL)
EXISTING EMPTY EMT
TO NEW HORN LOCATION
(TYPICAL)
PROVIDE NEW METAL
RACEWAY OR EMT
FOR HORIZONTAL
CABLE DISTRIBUTION
PROVIDE NEW METAL
RACEWAY OR EMT
FOR HORIZONTAL
CABLE DISTRIBUTION
KEYNOTES
REPLACE EXISTING IN-WALL SPEAKER WITH HORN AND STROBE,
BLANK OFF EXISTING SPEAKER
REPLACE EXISTING HORN(S), REPLACE WITH STROBE IN
PROTECTIVE CAGE
ROOM HAS HARD CEILING
MOUNT TO CEILING BEAM, REUSE EXISTING EMPTY LOW
VOLTAGE CONDUIT OR ADD NEW. EXTEND CONDUIT FROM BEAM
DOWN WALL WITH RACEWAY. ANGLE HORNS DOWN 45° TOWARD
OUTER WALLS
EXISTING PA SYSTEM EQUIPMENT AND RACK TO BE DEMO'D
MOUNT AT 12' AFG
MOUNT AT 10' AFF
WALL MOUNT HORN
S
S
15W
SYMBOL LEGEND
CEILING SPEAKER WITH SUPPORTS WHEN IN LAY-IN TILE
CEILING
IN WALL SPEAKER
HORN - WATTAGE AS NOTED
IP STROBE
2/19/2024 REBID EGH
1/19/2024 BIDDING EGH
DATE ISSUE AUTHOR
MEMPHIS COMMUNITY
SCHOOLS
ELEMENTARY SCHOOL
PAGING SYSTEM
ES-PA01
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
0' 5' 10' 20' 30' 40' 50'
NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS
136 137 127 128 129
135 134 126 125
RESTROOM
RESTROOM
122 121
LOUNGE
120 119 118
MEDIA
CENTER
WORKROOM
H.S. OFFICE
IDF 115C
BOYS
LOCKER
ROOM
GIRLS
LOCKER
ROOM
STAGE 112C
CAFETERIA
114 ROBOTICS
BOILER RECEIVING
SERVING KITCHEN
108 107 106
105104
LOUNGE
M.S.OFFICE
116117 MDF
IT OFFICE
GYMNASIUM
RESTROOM
RESTROOM
RESTROOM RESTROOM
15W
15W
15W
S S S S
S
S
S
S S S S S S S
S
S
S
S
15W
S
S
S
S
S
S
S
7.5W 7.5W
15W
15W
S
S
S
7.5W
S
S 15W
S
S
S
S
S
S
S
S
S S S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S
S
S
15W
S 15W
S
SS
S15W
15W
15W
15W
S
15WS
15W
15W
7.5W
15W
7.5W 7.5W 7.5W S S
7.5W 7.5W 7.5W
15W 15W
15W 15W
15W 15W
KEYNOTES
REPLACE EXISTING IN-WALL SPEAKER WITH HORN AND STROBE,
BLANK OFF EXISTING SPEAKER
REPLACE EXISTING IN-WALL SPEAKER WITH HORN(S), BLANK
OFF EXISTING SPEAKER
ROOM HAS HARD CEILING
LOCATION OF TWO-WAY SPEAKER, ALL OTHERS IN ROOM ARE
ONE-WAY ONLY
PROVIDE PROTECTIVE CAGE FOR DEVICES
MOUNT TO ROOF TRUSSES, ANGLE HORNS DOWN 45° TOWARD
OUTER WALLS
DEMO EXISTING WALL SPEAKER, BLANK OFF LOCATION. PAINT
BLANKS TO MATCH WALL COLOR
MOUNT AT 15' AFF, CONCEAL CABLE IN LATCH-DUCT RACEWAY
FROM CEILING
MOUNT ABOVE DOOR, CONCEAL CABLE IN LATCH-DUCT
RACEWAY FROM CEILING, OR POKE THROUGH FROM HALLWAY
S
S
15W
SYMBOL LEGEND
CEILING SPEAKER WITH SUPPORTS WHEN IN LAY-IN TILE
CEILING
IN WALL SPEAKER
HORN - WATTAGE AS NOTED
IP STROBE
2/19/2024 REBID EGH
1/19/2024 BIDDING EGH
DATE ISSUE AUTHOR
MEMPHIS COMMUNITY
SCHOOLS
JR/SR HIGH SCHOOL
PAGING SYSTEMS
JR.SR.HS-PA-01
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| MEMPHIS ES-PA101-ARCH D - REBID 2-19 |
| Sheets and Views |
| ARCH D |
| MEMPHIS JRSR-PA101-ARCH D REBID 2-19 |
| Sheets and Views |
| ARCH D |
File details come from the government source that posted it. Updated .