CERTIFIED ENVIRONMENTAL
August 2, 2017
Fort Vancouver National Historical Site
Mr. Alex Patterson
612 East Reserve Street
Vancouver, Washington 98661
LLC
RE: BULK SAMPLE COLLECTION AND ANALYSIS AT THE FORT VANCOUVER
NATIONAL HISTORICAL SITE BUILDINGS #748, #746, #752, #786, AND #725
AT, 612 EAST RESERVE STREET, IN VANCOUVER, WASHINGTON
Dear Mr. Patterson:
On July 26, 2017, Kyler Spears and Tom Thompson, C.E.C. AHERA certified building inspectors collected five samples of window glazing compound. The samples were collected from the windows of Buildings #748, #746, #752, #786, and #725. The samples were collected at the Fort Vancouver National Historical Site Buildings #748, #746, #752, #786, and #725 at, 612 East Reserve Street, in Vancouver, Washington to test for the presence of asbestos.
The samples were collected according to EPA AHERA rules and analyzed using polarized light microscopy with dispersion staining according to EPA and OSHA methodology.
The sample results indicate that the samples collected do not contain asbestos (please see sample data sheet). Please note that during the inspection it was determined that the window glazing compound present per building was homogenous with the other windows of the building sampled.
Please contact our offices, if there are any questions or concerns.
615 SE Chkalov Drive Suite 12 •Vancouver, Washington 98683-5280
Portland (503) 221-7904 • Vancouver (360) 254-9385 •Fax (360) 891-9633
P17PS01913, Attachment 5
• CERTIFIED ENVIRONMENTAL CONSULTING, LLC •
BULK SAMPLE ANALYSIS REPORT
CLIENT: FORT VANCOUVER NA TlONAL HISTORICAL SOURCE: FORT VANCOUVER NATIONAL
HISTORICAL SITE BUILDINGS #748, #746,
#752, #786, AND #725 AT, 612 EAST
RESERVE STREET, IN VANCOUVER,
WASHINGTON
SITE
MR. ALEX PATTERSON SAMPLED BY: KYLER SPEARS
LAB# CC-1727612 EAST RESERVE STREET
VANCOUVER, WASHINGTON 98661 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 07-26-17
DATE RECEIVED: 07-26-17
DATE COMPLETED: 07-28-17
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, A endix A, PLM/Dis ersion Stainin
SAMPLE
ID #
SAMPLE SAMPLE ASBESTOS CONTENT OTHER MATERIAL
DESCRIPTION LOCATION % TYPE
WlNDOW GLAZJNG
COMPOUND
WINDOW GLAZING
COMPOUND
WINDOW GLAZING
COMPOUND
WINDOW GLAZJNG
COMPOUND
WINDOW GLAZING
COMPOUND
ANALYST:
DEVIATION FROM METHOD: NONE.
PERCENT AGES ARE ESTIMATES.
BUILDJNG #748
WINDOW
BUILDING #746
WlNDOW
BUILDING #752
WlNDOW
BUILDING #786
WlNDOW
BUILDING #725
WINDOW
Ct!AI
TEST RESULTS PERTAIN ONLY TO ITEMS TESTED.
* DETECTION LIMIT IS LESS THAN I% ASBESTOS.
NON-ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
NONE DETECTED
NONE DETECTED
NONE DETECTED
NONE DETECTED
NONE DETECTED
CALCIUM CARBON A TE,
OIL
CALCIUM CARBONATE,
OIL
CALCIUM CARBON A TE,
OIL
CALCIUM CARBONATE,
OIL
CALCIUM CARBONATE,
OIL
615 SE CHKALOV DRIVE SUITE 12 • VANCOUVER, WASHINGTON 98683-5280
PORTLAND (503) 221-7904 •VANCOUVER (360) 254-9385 • FAX (360) 891-9633 OCL#l97023
<!tertif icate of <!Completion This is to certify that
Kyler Spears has satisfactorily completed
4 hours of refresher training as an
Asbestos Building Inspector to comply with the training requirements of
TSCA Title 11 / 40 CFR 763 (AHERA) lllstructor
EPA Provider Certificate #1085
Certificate#
160947 ljijftu§j�
•• "TI
TRAINJNi,•.C:ON.stJLtfN(i ('}
A1filrax:m<::�NY
Feb 1, 201]' Date(s) oflraining
Exam Score: NA Expiration Date: Feb 1, 2018
QCertif irate of QCompletion This is to certify that
Tommy M. Thompson has satisfactorily completed
4 hours of refresher training as an
Asbestos Building Inspector to comply with the training requirements of
TSCA Tille 11 / 40 CFR 763 (AHERA)
Certifica1e f.f
160990 ij;JffC,� ... .-:n Tl'.-'lMNG•CONSUL TIN<, ('}
,.��(I
Feb 8, 2017 Date{s) ofTraining
Exam Score:NA Expiration Date: Feb 8, 2018
QCertif irate of QCompletion This is to certify that
Tommy M. Thompson has satisfactorily completed
4 hours of refresher training as an
AHERA Asbestos Management Planner to comply with the training requirements of
TSCA Title II / 40 CFR 763 (AHERA)
Cert1!1ca1e #
160997
MIJBCI�
........... J:!
l'UJ/i!NG•CONS;JtTING ("')
,.lfurr-.c�, Feb 8, 2017 Oato(s) of Training
Exam Sc:':lre: NA Expiration Date: Feb 8,2018