P09 FINAL PG 1-110 Combined_Drawings.pdf
PDF 30 MB Posted
- Solicitation number
- 36C25523R0102
About this file
This document provides details for a federal contract solicitation to repair life safety deficiencies. The solicitation number is 36C25523R0102 and is being issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15. The solicitation seeks bids to address repair needs for ensuring life safety standards at a VA facility. The type of repairs or services required are not specified, nor are the response deadline, anticipated award date, or other contractual terms. The document attached appears to be construction drawings but no other context is provided.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25523R0102 0003.docx | DOCX document | |
| 36C25523R0102 0002.docx | DOCX document | |
| S05 AMEND 00001 36C25523R0102 0001 rev no attendance sheet.pdf | ||
| S02 36C25523R0102 Rev 1.pdf | ||
| 36C25523R0102.docx | DOCX document | |
| P09 FINAL SPECS PG 1-1260 589A5-21-101 Specifications.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BLDG 5
BLDG 4
CLIN-1. REMOVE BLDG. #5 ELEVATOR MODIFICATION
SCOPE. ANY WORK ASSOCIATED WITH THIS
MODIFICATION WILL NEED TO BE REMOVED FROM THE
PROJECT SCOPE.
CLIN-2. REMOVE BLDG. #4 ELEVATOR MODIFICATION
SCOPE. ANY WORK ASSOCIATED WITH THIS
MODIFICATION WILL NEED TO BE REMOVED FROM THE
PROJECT SCOPE.
CLIN (DEDUCT) LIST
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
U.S. DEPARTMENT OF VETERANS AFFAIRS
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:0
A
M
COVER SHEET
ECO 01 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA DEFICIENCIES
VA PROJECT NUMBER: 589A5-21-101
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
COLMERY-O'NEIL VA MEDICAL CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
BID DOCUMENTS
GI000
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[07] MECHANICAL
86 M-000 LEGEND AND ABBREVIATIONS
87 MH100 BUILDING 4 MECHANICAL HVAC PLAN - BASEMENT
88 MH101 BUILDING 4 MECHANICAL HVAC & PIPIING PLAN - FIRST FLOOR
89 MH102 BUILDING 4 MECHANICAL HVAC & PIPIING PLAN - SECOND FLOOR
90 MH103 BUILDING 4 MECHANICAL HVAC PLAN - PENTHOUSE
91 MH200 BUILDING 5 MECHANICAL HVAC PLAN - BASEMENT
92 MH201 BUILDING 5 MECHANICAL HVAC PLAN - FIRST FLOOR
93 MH202 BUILDING 5 MECHANICAL HVAC DUCT PLAN - SECOND FLOOR
94 MH203 BUILDING 5 MECHANICAL HVAC DUCT PLAN - PENTHOUSE
95 M-701 MECHANICAL DETAILS & SCHEDULES
[08] ELECTRICAL
96 E-000 ELECTRICAL LEGEND, SYMBOLS, AND ABBREVIATIONS
97 E-100 REFERENCE PLAN - BLDG 4 BASEMENT & FIRST FLOOR
98 E-101 REFERENCE PLAN - BLDG 4 SECOND FLOOR & PENTHOUSE
99 E-102 REFERENCE PLAN - BLDG 5 BASEMENT & FIRST FLOOR
100 E-103 REFERENCE PLAN - BLDG 5 SECOND FLOOR & PENTHOUSE
101 E-400 ENLARGED PLANS - BLDG 4 - BASEMENT & FIRST FLOOR
102 E-401 ENLARGED PLANS - BLDG 4 - SECOND FLOOR & PENTHOUSE
103 E-402 ENLARGED PLANS - BLDG 5 - BASEMENT & FIRST FLOOR
104 E-403 ENLARGED PLANS - BLDG 5 - SECOND FLOOR & PENTHOUSE
105 E-601 ELECTRICAL ONE-LINE DIAGRAM - BLDG 4
106 E-602 ELECTRICAL ONE-LINE DIAGRAM - BLDG 5
[09] VERTICAL CIRCULATION
107 VT001 GENERAL ELEVATOR INFORMATION
108 VT002 PLANS AND HOISTWAY SECTION - ELEVATOR BLDG 4
109 VT003 GENERAL ELEVATOR INFORMATION
110 VT004 PLANS AND HOISTWAY SECTION - ELEVATOR BLDG 5
TOTAL SHEETS: 110
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[04] ARCHITECTURAL
43 AS001 ARCHITECTURAL SITE PLAN
44 A-100 OVERALL PLAN - BLDG 4 - BASEMENT & FIRST FLOOR
45 A-101 OVERALL PLAN - BLDG 4 - SECOND FLOOR & PENTHOUSE
46 A-102 OVERALL PLAN - BLDG 5 - BASEMENT & FIRST FLOOR
47 A-103 OVERALL PLAN - BLDG 5 - SECOND FLOOR & PENTHOUSE
48 AE021 PARTITION TYPES
49 AE100 ENLARGED PLANS - BLDG 4 - CRAWL SPACE
50 AE101 ENLARGED PLANS - BLDG 4 - BASEMENT
51 AE102 ENLARGED PLANS - BLDG 4 - FIRST FLOOR
52 AE103 ENLARGED PLANS - BLDG 4 - SECOND FLOOR
53 AE104 ENLARGED PLANS - BLDG 4 - PENTHOUSE
54 AE105 ENLARGED PLANS - BLDG 5 - CRAWL SPACE
55 AE106 ENLARGED PLANS - BLDG 5 - BASEMENT
56 AE107 ENLARGED PLANS - BLDG 5 - FIRST FLOOR
57 AE108 ENLARGED PLANS - BLDG 5 - SECOND FLOOR
58 AE109 ENLARGED PLANS - BLDG 5 - PENTHOUSE
59 AE201 SECTIONS & DETAILS
60 AE202 DOOR SCHEDULE, PLAN & SECTION DETAILS
[05] FIRE PROTECTION
61 FA001 FIRE ALARM GENERAL NOTES, LEGEND, AND DIAGRAMS - BLDG 4
62 FA002 FIRE ALARM GENERAL NOTES, LEGEND, AND DIAGRAMS - BLDG 5
63 FA101 FIRE ALARM OVERALL PLAN - BLDG 4 - BASEMENT & FIRST FLOOR
64 FA102 FIRE ALARM OVERALL PLAN - BLDG 4 - PENTHOUSE & SECOND FLOOR
65 FA103 FIRE ALARM OVERALL PLAN - BLDG 5 - BASEMENT & FIRST FLOOR
66 FA104 FIRE ALARM OVERALL PLAN - BLDG 5 - PENTHOUSE & SECOND FLOOR
67 FA401 FIRE ALARM PLANS - BLDG 4 - ENLARGED
68 FA402 FIRE ALARM PLANS - BLDG 5 - ENLARGED
69 FX101 FIRE SUPPRESSION OVERALL PLAN - BLDG 4 - BASEMENT & FIRST FLOOR
70 FX102 FIRE SUPPRESSION OVERALL PLAN - BLDG 4 - PENTHOUSE & SECOND FLOOR
71 FX103 FIRE SUPPRESSION OVERALL PLAN - BLDG 5 - BASEMENT & FIRST FLOOR
72 FX104 FIRE SUPPRESSION OVERALL PLAN - BLDG 5 - PENTHOUSE & SECOND FLOOR
73 FX401 FIRE SUPPRESSION HAZARD CLASSIFICATION PLANS - BLDG 4 - ENLARGED
74 FA003 FIRE SUPPRESSION HAZARD CLASSIFICATION PLANS - BLDG 5 - ENLARGED
[06] PLUMBING
75 P-000 PLUMBING LEGEND
76 PP100 BUILDING 4 PLUMBING PIPING PLAN - CRAWL SPACE
77 PP101 BUILDING 4 PLUMBING PIPING PLAN - BASEMENT
78 PP102 BUILDING 4 PLUMBING PIPING PLAN - FIRST FLOOR
79 PP103 BUILDING 4 PLUMBING PIPING PLAN - SECOND FLOOR
80 PP104 BUILDING 4 PLUMBING PIPING PLAN - PENTHOUSE
81 PP200 BUILDING 5 PLUMBING PIPING PLAN - CRAWL SPACE
82 PP201 BUILDING 5 PLUMBING PIPING PLAN - BASEMENT
83 PP202 BUILDING 5 PLUMBING PIPING PLAN - FIRST FLOOR
84 PP203 BUILDING 5 PLUMBING PIPING PLAN - SECOND FLOOR
85 PP204 BUILDING 5 PLUMBING PIPING PLAN - PENTHOUSE
SHEET INDEX
SEQUENCE NUMBER SHEET NAME
[01] GENERAL
01 GI000 COVER SHEET
02 GI001 GENERAL INFORMATION
03 GI002 LIFE SAFETY PLANS - BUILDING 4
04 GI003 LIFE SAFETY PLANS - BUILDING 4
05 GI004 LIFE SAFETY PLANS - BUILDING 5
06 GI005 LIFE SAFETY PLANS - BUILDING 5
07 GI006 PHASING PLAN - BLDG 4 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE ONE
08 GI007 PHASING PLAN - BLDG 4 - SECOND FLOOR & PENTHOUSE - PHASE ONE
09 GI008 PHASING PLAN - BLDG 4 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE TWO
10 GI009 PHASING PLAN - BLDG 4 - SECOND FLOOR & PENTHOUSE - PHASE TWO
11 GI010 PHASING PLAN - BLDG 4 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE THREE
12 GI011 PHASING PLAN - BLDG 4 - SECOND FLOOR & PENTHOUSE - PHASE THREE
13 GI012 PHASING PLAN - BLDG 5 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE ONE
14 GI013 PHASING PLAN - BLDG 5 - SECOND FLOOR & PENTHOUSE - PHASE ONE
15 GI014 PHASING PLAN - BLDG 5 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE TWO
16 GI015 PHASING PLAN - BLDG 5 - SECOND FLOOR & PENTHOUSE - PHASE TWO
17 GI016 PHASING PLAN - BLDG 5 - CRAWL SPACE, BASEMENT, AND FIRST FLOOR - PHASE THREE
18 GI017 PHASING PLAN - BLDG 5 - SECOND FLOOR & PENTHOUSE - PHASE THREE
[02] HAZARDOUS MATERIALS
19 HA000 ENVIRONMENTAL HAZARDS - GENERAL NOTES
20 HA004 BUILDING 4 - CRAWLSPACE - ENVIRONMENTAL HAZARDS
21 HA400 BUILDING 4 - BASEMENT - ENVIRONMENTAL HAZARDS
22 HA401 BUILDING 4 - FIRST FLOOR - ENVIRONMENTAL HAZARDS
23 HA402 BUILDING 4 - SECOND FLOOR - ENVIRONMENTAL HAZARDS
24 HA403 BUILDING 4 - PENTHOUSE - ENVIRONMENTAL HAZARDS
25 HA005 BUILDING 5 - CRAWLSPACE - ENVIRONMENTAL HAZARDS
26 HA500 BUILDING 5 - BASEMENT - ENVIRONMENTAL HAZARDS
27 HA501 BUILDING 5 - FIRST FLOOR - ENVIRONMENTAL HAZARDS
28 HA502 BUILDING 5 - SECOND FLOOR - ENVIRONMENTAL HAZARDS
29 HA503 BUILDING 5 - PENTHOUSE - ENVIRONMENTAL HAZARDS
[03] STRUCTURAL
30 S-001 STRUCTURAL GENERAL NOTES
31 S-100 BLDG 4 - CRAWL SPACE
32 S-101 BLDG 4 - BASEMENT
33 S-102 BLDG 4 - FIRST FLOOR
34 S-103 BLDG 4 - SECOND FLOOR
35 S-104 BLDG 4 - PENTHOUSE / ROOF
36 S-105 BLDG 5 - CRAWL SPACE
37 S-106 BLDG 5 - BASEMENT
38 S-107 BLDG 5 - FIRST FLOOR
39 S-108 BLDG 5 - SECOND FLOOR
40 S-109 BLDG 5 - PENTHOUSE / ROOF
41 S-500 SECTIONS
42 S-501 SECTIONS
04 & 05
LOCATION MAP
N
No. REVISION DESCRIPTION DATE
ABBREVIATIONS CODES STANDARDS AND EXECUTIVE ORDERS
4' -0
M
A X
4' -0
M
A X
2' -1
0" M
A X
2' -3
M
IN
1'-6" MIN
1. GENERAL CONTRACTOR TO PROVIDE METAL SUPPORT
BLOCKING FOR ALL WALL MOUNTED ACCESSORIES,
FIXTURES, AND EQUIPMENT.
2. PROVIDE ADA SUPPORT BRACKETS PLACED AT ALL OPEN
COUNTERTOPS @ 36"-48" MAX ON CENTER.
3. SPECIFIED MAXIMUMS ARE MEASURED FROM AFTER
FINISHED FLOOR TO THE OPERABLE PART OF THE FIXTURE.
4. FIXTURES SHOWN ARE REPRESENTATIONAL ONLY. NOT ALL
FIXTURES MAY BE USED. REFER TO SPECIFICATIONS FOR
FIXTURE TYPES USED IN THIS PROJECT.
5. FIXTURES MAY OVERLAP WAINSCOT. WHERE APPLICABLE,
BACKING TO BE PROVIDED AS SHIM FOR FLUSH
APPLICATION. SHIM TO MATCH SCHEDULED WALL FINISH.
6" MAX
9" M
IN
SHOWER
TOILET ROOM
TURNING RADIUS
DRINKING
FOUNTAIN
PAPER TOWEL
DISPENSER
SANITARY
NAPKIN
DISPENSER
4' -0
"M A
X
WASTE
RECEPTACLE
LAVATORY
WITH MIRROR
ON CENTER
WALL
4' -0
M
A X
SOAP
DISPENSER
2' -1
0" M
A X
T O
B .O
. R E
F
LE
C T
IV
E
S U
R F
A C
E
3' -4
"M A
X
17 MIN
2' -3
M
IN
3' -0
M
A X
1'-6" MIN
WALL
2' -9
" 4' -0
M
IN
2'-0" MIN
8" MIN
WALL
LAVATORY
WITH APRON
1' -5
M
A X
1'-6" MIN
URINAL
WALL
1'-5" - 1'-7" (AMBULATORY)
1'-4" - 1'-6" (WHEELCHAIR)
CLEAR FLOOR
5'-6"
CLEAR FLOOR
6'-0"
3'-0" MIN
2' -9
3' -0
1'-0" MIN
3'-6" MIN 1'-0"MAX
4'-6" MIN
1' -5
'-7
1' -6
M
IN
A N
S I I
C C
A
7.
1)
1' -3
M
IN
A D
A /A
B A
2' -9
'-0
WALL
WALL
4' -0
M
A X
WALL HOOK
7' -0
CLOCK
WALL
FINISHED FLOOR
FIRE EXTINGUISHER
CABINET
WEIGHT > 40LBS
FIRE EXTINGUISHER
CABINET
WEIGHT < 40LBS
4' -0
"M A
X
4' -0
M
A X
TOILET SEAT
COVER
DISPENSER
BABY
CHANGING
STATION
CLEAR FLOOR SPACE
@ WATER CLOSET
5'-6"
2'-6"
4' -0
2'-6"
4' -0
HANDRAILS AND
BUMPERGUARDS
FIXTURE MOUNTING HEIGHTS AND CLEARANCES
18" MIN
M
IN
FRONT APPROACH,
PULL SIDE
36" MIN
M
IN
HINGE APPROACH,
PULL SIDE
HINGE APPROACH,
PULL SIDE
*12" MIN48
M
IN
FRONT APPROACH,
PUSH SIDE
M
IN
HINGE APPROACH,
PUSH SIDE
22" MIN 24" MIN
*4 8"
M
IN
LATCH APPROACH,
PULL SIDE
24" MIN*4
2"
M
IN
LATCH APPROACH,
PUSH SIDE
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
*54" MIN IF CLOSER
IS PROVIDED
*48" IF CLOSER IS
PROVIDED
FRONT APPROACH,
PUSH SIDE
M
IN
42" MIN
DOOR AND FIXTURE CLEARANCES
MATERIALS LEGEND
PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN
VOLUNTARY STANDARD BODIES.
GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS
SPECIFY OTHER CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:
• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL
INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).
• 2021 INTERNATIONAL BUILDING CODE (IBC) (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE NOTES BELOW)
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC) (IF APPLICABLE)
• 2021 NFPA 101 LIFE SAFETY CODE (SEE NOTES BELOW)
• 2021 NATIONAL FIRE CODES (NFPA)
• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.
• 2020 VA SEISMIC DESIGN REQUIREMENTS, H-18-8
• 2020 NATIONAL ELECTRICAL CODE (NEC), NFPA 70
• 2021 INTERNATIONAL PLUMBING CODE (IPC)
• 2016 SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.
• 2015 ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS INCLUDING VA SUPPLEMENT, VA BARRIER FREE DESIGN STANDARD (PG-18-13)
• 2017 ANSI ICC A117.1 ACCESIBLE AND USABLE BUILDINGS AND FACILITIES
• 2019 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY, AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318-19)
• 2017 STEEL CONSTRUCTION MANUAL (15TH EDITION), AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
• ENERGY POLICY ACT OF 2005 (EPACT)
• 2007 DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND
NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.
• 2006 FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING (MOU)
• 2018 EXECUTIVE ORDER 13834: EFFICIENT FEDERAL OPERATIONS
• 2021 THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 010000 OF THE VA MASTER CONSTRUCTION
SPECIFICATION.
• 2019 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1
• 2019 SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15
LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW OR INSPECTION FEES.
NOTES:
1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT
NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN.
DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS APPLIES
EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).
2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.
ASHRAE 90.1 - 2019 EDITION
BUILDING LOCATION:
CLIMATE ZONE (TABLE ANNEX 1-1): ZONE 4A
INTERIOR DESIGN CONDITIONS:
THE INTERIOR DESIGN TEMPERATURES FOR HEATING AND COOLING AS DEPICTED IN THE PROJECT DESIGN CONDITIONS SCHEDULE IN THE MECHANICAL CONTROL DRAWINGS SHALL BE THE MAXIMUM
AND MINIMUM VALUES FOR THE ASSOCIATED TEMPERATURE CONTROL ZONES.
BUILDING ENVELOPE REQUIREMENTS (5.5 )
BUILDING ENVELOPE REQUIREMENTS FOR CLIMATE ZONE 4 (A,B,C)
ROOFS REQUIRED DESIGNED
INSULATION: R-30 c.i. EXISTING METAL BUILDINGS: R-19 + R-11 Ls or R-25 + R-8 Ls EXISITING
ATTIC AND OTHER: R-49 EXISTING
WALLS, ABOVE GRADE
MASS: R-9.5 c.i. EXISTING METAL BUILDING: R-0 + R-15.8 c.i. EXISTING STEEL-FRAMED: R-13 + R-7.5 c.i. EXISTING WOOD-FRAMED AND OTHER: R-13 + R-3.8 c.i. or R-20 EXISTING
WALL, BELOW GRADE
BELOW-GRADE WALL: R-7.5 c.i. EXISTING
FLOORS
MASS: R-14.6 c.i. EXISTING
STEEL-FRAMED: R-30 EXISTING
WOOD-FRAMED AND OTHER: R-30 EXISTING
SLAB-ON-GRADE FLOORS
UNHEATED SLABS: R-15 for 24 in. EXISTING HEATED SLABS: R-20 for 24 in. EXISTING
OPAQUE DOORS
SWINGING: U-0.370 EXISTING
NONSWINGING: U-0.310 EXISTING
FENESTRATION (TABLE 5.5-4):
VERTICAL FENESTRATION, U-FACTOR
FIXED: U-0.36 EXISTING
OPERABLE: U-0.45 EXISTING
ENTRANCE DOOR: U-0.63 EXISTING
DEFINITIONS
c.i = CONTINUOUS INSULATION Ls = LINEAR SYSTEM
NR = NO (INSULATION) REQUIREMENT
ENERGY REQUIREMENTS
N
1. DRAWINGS ARE PART OF A COMPLETE DOCUMENTS SET. CONTRACTOR SHALL
CONFIRM ALL ITEMS REQUIRED BASED UPON THE OVERALL DESIGN INTENT OF THE
ENTIRE DOCUMENT SET.
2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, PRIOR TO BEGINNING ANY
WORK, TO CONFIRM THE ACCURACY OF THE DRAWINGS AND REPORT ANY
DISCREPANCIES TO THE ARCHITECT. DO NOT SCALE THE DRAWINGS. FIELD VERIFY
ALL DIMENSIONS AND EXISTING STRUCTURAL CONDITIONS.
3. ALL AREAS NOT INVOLVED IN THE SCOPE OF WORK FOR THIS PROJECT SHALL BE KEPT
CLEAN AND FREE OF OBSTRUCTIONS AT ALL TIMES.
4. ERECT BARRICADES AND WARNING SIGNS TO DIVERT AND WARN PASSERS-BY OF THE
CONSTRUCTION WORK. PROVIDE DUST PROOFING ENCLOSURES TO SEPARATE WORK
AREAS FROM THE EXISTING FACILITIES.
5. ALL TRASH AND DEBRIS TO BE REMOVED ON A DAILY BASIS.
6. PROVIDE PROTECTION FOR ALL EXISTING SURFACES AND CONDITIONS TO REMAIN IN
PLACE DURING THE SCOPE OF WORK. SHOULD ANY DAMAGE OCCUR, PATCH AND
REPAIR ANY DAMAGE TO ADJACENT FINISHES TO MATCH EXISTING.
7. ANY DAMAGE CAUSED TO THE BUILDING OR OWNER EQUIPMENT SHALL BE REPAIRED
OR REPLACED BACK TO ITS ORIGINAL CONDITIONS AT NO ADDITIONAL COST TO THE
OWNER.
8. COVER ALL RETURN AIR GRILLES WITHIN THE AREA OF CONSTRUCTION TO PREVENT
PARTICULATE MATERIAL FROM EXHAUSTING INTO SURROUNDING SPACES.
9. APPROPRIATE LIGHT FIXTURES SHALL BE TEMPORARILY SUSPENDED TO PROVIDE
ADEQUATE LIGHTING LEVELS FOR CONSTRUCTION.
10. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO COORDINATE WITH OTHER
DISCIPLINES TO INSTALL COMPLETE AND OPERATIONAL SYSTEMS. DRAWINGS, AS A
WHOLE, REPRESENT A COMPLETE SET AND DEPICT REQUIREMENTS FOR COMPLETE
AND OPERATIONAL SYSTEMS. INDIVIDUAL DRAWINGS MAY NOT DEPICT COMPLETE AND
ACCURATE INFORMATION TO COORDINATE COMPLETE AND OPERATIONAL SYSTEMS,
BUT DO SO AS AN ENTIRE DOCUMENT TO BE REFERENCED WITH OTHER INDIVIDUAL
DRAWINGS. CONTRACTOR AND SUBCONTRACTORS ARE REQUIRED TO REFERENCE
OTHER SHEETS AND SPECIFICATIONS AS AN ENTIRE SET OF CONSTRUCTION
DOCUMENTS THAT REFLECT WORK REQUIRED TO ACHIEVE A COMPLETE AND
OPERATIONAL GOAL. LACK OF COORDINATION AND REVIEW OF DRAWINGS AND
SPECIFICATIONS AS AN ENTIRE DOCUMENT TO INSTALL COMPLETE AND OPERATIONAL
SYSTEMS, BEING OBVIOUS AND TYPICAL INDUSTRY STANDARD, IDENTIFIED IN THE
DRAWINGS AND SPECIFICATIONS, SHALL NOT BE IN ANY WAY AN ADDITIONAL COST TO
THE GOVERNMENT.
11. CONTRACTOR SHALL SUBMIT A REQUEST, IN WRITING, TO INTERRUPT ANY SUCH
SERVICES TO COR (CONTRACTING OFFICER’S REPRESENTATIVE) 48 HOURS IN
ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE,
EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. MAJOR
INTERRUPTIONS OF ANY SYSTEM MUST BE REQUESTED, IN WRITING, AT LEAST 60
CALENDAR DAYS PRIOR TO THE DESIRED TIME AND SHALL BE PERFORMED AS
DIRECTED BY THE COR. MAJOR INTERRUPTIONS SHALL BE COORDINATED WITH OTHER
MAJOR INTERRUPTIONS AND MAY NOT BE SCHEDULED FOR ONE DISCIPLINE MORE
THAN TWICE THROUGHOUT THE OVERALL CONSTRUCTION SCHEDULE UNLESS
REQUESTED IN WRITING AND APPROVED BY THE COR. CONTRACTOR WILL BE ADVISED,
IN WRITING, OF APPROVAL OF REQUEST, OR OF WHICH OTHER DATE AND/OR TIME
SUCH INTERRUPTION WILL CAUSE THE LEAST INCONVENIENCE TO OPERATIONS OF
THE MEDICAL CENTER. INTERRUPTION TIME APPROVED BY THE MEDICAL CENTER MAY
OCCUR AT TIMES OTHER THAN CONTRACTOR'S NORMAL WORKING HOURS. SCHEDULE
INTERRUPTION MAY BE ON WEEKENDS OR LATE HOURS AND MAY NOT BE AN
ADDITIONAL COST TO THE GOVERNMENT. COORDINATE ALL INTERRUPTIONS THAT MAY
AFFECT THE NORMAL OPERATION OF THE FACILITY WITH THE COR WHEN SUBMITTING
THE CONSTRUCTION SCHEDULE OR UPDATES TO THE CONSTRUCTION SCHEDULE.
12. NO ASBESTOS CONTAINING MATERIALS ARE TO BE USED ON THIS PROJECT. SPUR
DESIGN, THE A/E OF RECORD, CAN CERTIFY THAT NO ASBESTOS CONTAINING
BUILDING MATERIALS (ACBM) OR LEAD BASED PAINT (LBP) PRODUCTS WERE
DESIGNED/SPECIFIED AS BUILDING MATERIAL IN ANY OF THE CONSTRUCTION
DOCUMENTS.
13. REFER TO THE DESIGN BINDER FOR THE ICRA INFORMATION DOCUMENTATION.
GENERAL NOTES
AREA NAME
150 SF
A101
A101
SIM
A
00.0
A101
1 1
A101
LEVEL NAME
00'-00"
00'-00" 4B
3A
FIBERGLASS BATT
INSULATION
RIGID INSULATION
CONCRETE / PRECAST
CONCRETE
EARTH / SOIL
SAND, EIFS FINISH, OR
PLASTER FINISH
GYPSUM BOARD FINISH
BRICK
CONCRETE MASONRY
UNIT
STONE / CAST STONE
GYPSUM BOARD SECTION
EXTERIOR SHEATHING
BOARD SECTION
PLYWOOD SECTION
ROOM NAME
000A
150 SF
/1 A101
X0000
6"
3' -0
M
A X
ROOM TAG
AREA TAG
SPECIALTY EQUIPMENT TAG
DOOR TAG
KEYED NOTE TAG
WALL TAG
WINDOW TAG
A101
SIM
A101
SIM
A
ACB ACOUSTIC CEILING BAFFLE
ACP ACOUSTIC CEILING PANEL
ACST ACOUSTIC
ADA AMERICANS WITH DISABILITIES ACT
ACT ACOUSTICAL CEILING TILE
ADDL ADDITIONAL
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR
ADJUSTABLE
ADMIN ADMINISTRATION
AE ARCHITECT/ENGINEER
AF ACCESS FLOORING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHJ AUTHORITY HAVING JURISDICTION
AIA AMERICAN INSTITUTE OF
ARCHITECTS
ALT ALTERNATE
ALT NO ALTERNATE NUMBER
ALUM ALUMINIUM (TRIM)
AMT AMOUNT
APPROX APPROXIMATE
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
AT ACOUSTIC CEILING TILE
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BOS BOTTOM OF STEEL
BOT BOTTOM
BRKT BRACKET
BTWN BETWEEN
C
CAB CABINET
CAV CAVITY
CBB CONCRETE BACKER BOARD
CD CONSTRUCTION DOCUMENTS
CFM CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CH BD CHALK BOARD
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CONTRACTING OFFICER
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CP CONTRACTOR PROVIDED
CP/CI CONTRACTOR PROVIDED /
CONTRACTOR INSTALLED
CPT CAROET/CARPET TILE
CS CONCRETE SEALED
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTR CENTER
CU FT CUBIC FEET
D
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
DWG DRAWING
DWP DIMENSIONAL WALL PANEL
E
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPY EPXOY FLOORING
EQ EQUAL
ETR EXISTING TO REMAIN
EX EXISTING
EXP EXPOSED
EXT EXTERIOR
F
FAB FABRIC
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FP FIRE PROTECTION
FR FIRE RESISTANT
FT FEET
FTG FOOTING
FV FIELD VERIFY
FWC FABRIC WALL COVERING
G
GDR GUARDRAIL
GL GLASS/GLAZING
GRAN GRANITE
GR FL GROUND FLOOR
GT GROUT
GSM GALVANIZED SHEET METAL
GYP BD GYPSUM BOARD
H
HDW HARDWARE
HEPA HIGH EFFICIENCY
PARTICULATE AIR (FILTER)
HMD HOLLOW METAL DOOR PAINT
HMDF HOLLOW METAL DOOR FRAME
PAINT
HMWF HOLLOW METAL WINDOW FRAME
PAINT
HORIZ HORIZONTAL
HR HANDRAIL
HT HEIGHT
HW HARDWARE
I
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J
J-BOX JUNCTION BOX
L
LAV LAVATORY
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIN LINEAR
LN LINOLEUM
LOC LOCATION
LT LIGHT
LVR LOUVER
LVT LUXURY VINYL TILE
M
MAT CARPET MAT / WALK-OFF MAT
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODIFY
MTG MOUNTING
MTL METAL
MVBL MOVABLE
N
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P
P PAINT
PA PUBLIC ADDRESS
PBD PARTICLE BOARD
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PERP PERPENDICULAR
PL PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PNL PANEL
PR PAIR
PRB PROFILE BASE
PRKG PARKING
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PORCELAIN TILE
PWR POWER
Q
QA QUALITY ASSURANCE
QC QUALITY CONTROL
QTY QUANTITY
REFERENCE SYMBOLS IDENTIFICATION TAGS
NOTE: NOT ALL ABBREVIATIONS OR SYMBOLS WILL BE UTILIZED FOR THIS PROJECT.
GRID HEAD AND
LINE
LEVEL INDICATOR
MATCH LINE AND
VIEW REFERENCE
NORTH ARROW W/
PROJECT NORTH
SPOT ELEVATION
DETAIL
SECTION
**48" MIN IF BOTH CLOSER
AND LATCH PROVIDED
WALL
SECTION
BUILDING
SECTION
DETAIL
ELEVATION
INTERIOR
ELEVATION
BUILDING
ELEVATION
1 1
6'- 0"
5'- 0"
BARIATRIC TOILET ROOM
TURNING RADIUS
CLEAR FLOOR SPACE
@ ADA LAVATORY
CLEAR FLOOR SPACE @ ADA
DRINKING FOUNTAIN
4"
6"
3"
6" 1'
-6
6" MAX
7" - 9" 11" MIN
17" - 25"
M
IN
6' -0
(ANSI ICC A117.1)
39"- 41"
(A N
S I I
C C
A
7.
1)
M
IN
(A N
S I I
C C
A
7.
1)
1"
3' -6
M
A X
5' -0
M
A X
R
RAF RESILIENT ATHETIC FLOORING
RB RUBBER BASE/RESILIENT BASE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REC RECESSED
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RES RESINOUS FLOORING
RES-W RESINOUS / EPOXY WALL / CEILING
RF RUBBER FLOORING
RFG ROOFING
RM ROOM
RO ROUGH OPENING
RP RESIN PANEL
RSF RESILIENT SHEET FLOORING
RV ROOF VENT
RWC RIGID VINYL WALLCOVERING
S
SC SPECIALTY COATING
SD STATIC DISSIPATIVE FLOORING/TILE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT (FEET)
SGL SINGLE
SIM SIMILAR
SJ SCORED JOINT
SLNT SEALANT
SM SHEET METAL
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SS SOLID SURFACE
ST STONE
STD STANDARD
STOR STORAGE
SV SHEET VINYL (ROLLED OR TILE)
T
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZO
TOF TOP OF FOOTING/ FOUNDATION
TOM TOP OF MASONRY
TOS TOP OF SLAB/ STEEL
U
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
V
VAR VARIES
VC VA PROVIDED / CONTRACTOR
INSTALLED
VCT VINYL COMPOSITION TILE
VFAT VINYL FACED ACOUSTICLAL TILE
VP VENEERED PLASTER
VT VINYL TILE
VV VA PROVIDED / VA INSTALLED
VWC VINYL WALLCOVERING
VWF VINYL WALL FABRIC
W
W/ WITH
W/O WITHOUT
W/C WATER CLOSET
WC WHEELCHAIR
WD WOOD
WFAB WALL FABRIC
WPM WATERPROOF MEMBRANE
WSF WELDED SHEET FLOOR
X
X BRACE CROSS BRACE
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:0
A
M
GENERAL INFORMATION
ECO 02 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
GI001
04 & 05
A
A0-E9
A13 A14
A24A A24A01
A11
A02
A0-C1
A01A A24B
A2E A01E
A0-S1
A0-E10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A
B
CRAWL SPACE
CRAWL SPACE
C
UP
B09A
B08
CRAWL SPACE
B08F B09 B0-C1
B07E
B07 B06 B05 B04 B03
C0-C1
B09B
OPEN TO BELOW
DN
C17 C17F
C15 C15A
C17A
E C18
CRAWL SPACE
F
C19E
C23 C22 C21 C20
G C19
TO MECHANICAL
ACCESS PIT,
OPEN TO EXTERIOR
H
C15B
C17B UP
D1
D
CRAWL SPACE
CRAWL SPACE
J
A
A
A141 A139
A1-E9
A1-C4
A103 A102
A101A
A114 A145
B134
A143
A103E
A102E
A0-E10
A101
A1-C2
UP
DN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A137
A
B127A
A138 B127 B128 C154 C155
A136
C153 A1-C3
B126 B129
C152
A136A B126A
A138A
B129A
B125A
B121
B119 B120 B121A
B121E
B119A B1-C3
B123
B115E B1-C1
B115
B118 B117
B116A B114
C173
B113
DN
DN
B112 B110
C175 C174
C175A C174A
C172
H
B116 B1-C4 B108
B109
B107
B106 B105 B104
B122 B1-S3
UP UP
B131
C1-3
G
B1-C2
B132 B133
C143A
C143B C143
C146B
C171
C147 C148 C168
C170 C169A C169
B125
B125F
B132A
C144
C142
C142A
C145 C146
C146C
F
C146A C160
C149 C161
C170E C163A C1-C1
C163E
C144A
C1-S2
UP UP
B130
C150
UP
C162
C163 C164
C165
C166 C167
E
C158F C158 DN
D1
D
C1-C2 C151 C157
C
DN
DN
C156
B
J
AREA NOT IN SCOPE
EGRESS PATH
BUILDING EXIT
OCCUPANT LOAD
NFPA 101-2021 EDITION
CONSTRUCTION TYPE: (NFPA-220 TABLE 4.1.1 IN ACCORDANCE WITH THE VA FIRE PROTECTION
DESIGN MANUAL 2.1): TYPE II (000)
BUILDING HEIGHT: (TABLE 19.1.6.1)
2 STORIES, 24'-9" HEIGHT
BUILDING AREA:
AREA LIMITATION: NOT APPLICABLE (NFPA-101)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
FIRE RESISTANCE RATINGS (NFPA-220 SECTION 5.1 IN ACCORDANCE WITH THE VA FIRE
PROTECTION DESIGN MANUAL 2.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
CHAPTER 19: EXISTING HEALTHCARE OCCUPANCY
OCCUPANT LOADS (TABLE 7.3.1.2):
• BASEMENT FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• FIRST FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SECOND FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SEE TABLE BELOW FOR ROOMS AFFECTED BY CONSTRUCTION.
ELEVATOR HOISTWAYS (NFPA TABLE 7.3.1.2)
SHAFTS MINIMUM 1-HOUR RATING (NFPA 7.1.3.2.1)
• 3-STORIES OR LESS IS 1-HOUR RATING FOR SHAFT ENCLOSURE.
DEAD END CORRIDOR MAXIMUM DISTANCE: 30' (NFPA-101 19.2.5.3) N/A
MAXIMUM COMMON PATH OF TRAVEL: 100' (NFPA-101 19.2.5.5) N/A
MAXIMUM TRAVEL DISTANCE: 200' (NFPA-101 19.2.6.2.1) N/A
CORRIDOR MINIMUM FIRE RATING: 0 HR (NFPA-101 19.3.6.1 EXCEPTION 3) N/A
ALL EXIT DOORS PROVIDED ARE EXISTING AND NOT PART OF THIS SCOPE OF WORK.
STAIR WIDTH PROVIDED IS EXISTING AND NOT PART OF THIS SCOPE OF WORK.
PROTECTED AREAS:
- NOT APPLICABLE AS PART OF THE SCOPE OF WORK FOR THIS PROJECT..
SMOKE COMPARTMENTALIZATION:
- NOT APPLICABLE.
FIRE ALARM SYSTEM:
- EXISTING TO REMAIN.
STANDPIPES:
- EXISTING TO REMAIN.
FIRE - 1 HOUR
FIRE - 2 HOUR
FIRE / SMOKE - 1 HOUR
FIRE / SMOKE - 2 HOUR
TRAVEL DISTANCE: 59'-9"
TRAVEL DISTANCE: 75'-7"
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
AREA
OCC. LOAD
FACTOR IN SF
OCC. LOADOCCUPANT ROOM TYPEROOM
STORAGE USE, OTHER N/A
15 NET
A14
A141
130 SF
143 SF
N/A
OCCUPANT LOAD PER NFPA 101-2021
PER TABLE 7.3.1.2
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:0
A
M
LIFE SAFETY PLANS - BUILDING 4
ECO 03 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
GI002
LIFE SAFETY LEGEND
LIFE SAFETY REQUIREMENTS
RATED PARTITIONS & BARRIERS
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 4 - BASEMENT1
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 4 - FIRST FLOOR2
N
A144
A238
A2-9
A270 A269
A113
A271
A202A203
A234A A234
AS-S1 A236
A106
A107
A234F A0-E10
DN
UP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
ROOF BELOW
A
B227A
B227 B228 C244
C247G
C244A
B
B226 B229
ROOF BELOW
C2-C2 B226A
B2-C2
B229A B225A
B221 B220
B219 B220A
B221E
B218A B2-C3
B223
B215E B2-C1
B222
UP
B231
B218 B217
B216A
B214
B213
ROOF BELOW
H
B212 B210 C262 C261
B215 B216 B2-C4
B208 B209
B207
B206 B205 B204 C268 C267
C2-C4 C264
C258
C259
C255A
G
C265 C263
C2-C1
C266
C257
C256 C255 C254
C2-C3
B232 B233
B225
B225F B232A
C239
C240 C241
C249
C256E
C251E
C253A
F
E
C239A C2-S2
UP
C250 C251
C251A C252 C253
B230 ROOF BELOW
C242 C247F
C243A
C247A
C247
C246A C
D1
D
C243 C246
J
B -S
A
A144
A238
A2-9
A270 A269
A113
A271
A202A203
A234A A234
AS-S1 A236
A106
A107
A234F A0-E10
DN
UP
10 11 12 13 14 15 16 17 18 19 20 21
ROOF BELOW
C244 C247G
C244A
ROOF BELOW
C2-C2
ROOF BELOW
C262 C261
B204 C268 C267 C2-C4
C264 C258
C259
C265 C263
C2-C1
C266
C257
C2-C3
B233 C239
C240 C241
C249
C256E
C239A C2-S2
UP
ROOF BELOW
C242 C247F
C243A
C247A
C247
C246A
C243 C246
TRAVEL DISTANCE: 67'-6"
TRAVEL DISTANCE: 86'-8"
D1
D
E
F
G
10 11 12 13 14 15 17 18 19 20 21 22 23 24 250807060504030201 09
C
B
A
A301
14.5
DA
NFPA 101-2021 EDITION
CONSTRUCTION TYPE: (NFPA-220 TABLE 4.1.1 IN ACCORDANCE WITH THE VA FIRE PROTECTION
DESIGN MANUAL 2.1): TYPE II (000)
BUILDING HEIGHT: (TABLE 19.1.6.1)
2 STORIES, 24'-9" HEIGHT
BUILDING AREA:
AREA LIMITATION: NOT APPLICABLE (NFPA-101)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
FIRE RESISTANCE RATINGS (NFPA-220 SECTION 5.1 IN ACCORDANCE WITH THE VA FIRE
PROTECTION DESIGN MANUAL 2.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
CHAPTER 19: EXISTING HEALTHCARE OCCUPANCY
OCCUPANT LOADS (TABLE 7.3.1.2):
• BASEMENT FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• FIRST FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SECOND FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SEE TABLE BELOW FOR ROOMS AFFECTED BY CONSTRUCTION.
ELEVATOR HOISTWAYS (NFPA TABLE 7.3.1.2)
SHAFTS MINIMUM 1-HOUR RATING (NFPA 7.1.3.2.1)
• 3-STORIES OR LESS IS 1-HOUR RATING FOR SHAFT ENCLOSURE.
DEAD END CORRIDOR MAXIMUM DISTANCE: 30' (NFPA-101 19.2.5.3) N/A
MAXIMUM COMMON PATH OF TRAVEL: 100' (NFPA-101 19.2.5.5) N/A
MAXIMUM TRAVEL DISTANCE: 200' (NFPA-101 19.2.6.2.1) N/A
CORRIDOR MINIMUM FIRE RATING: 0 HR (NFPA-101 19.3.6.1 EXCEPTION 3) N/A
ALL EXIT DOORS PROVIDED ARE EXISTING AND NOT PART OF THIS SCOPE OF WORK.
STAIR WIDTH PROVIDED IS EXISTING AND NOT PART OF THIS SCOPE OF WORK.
PROTECTED AREAS:
- NOT APPLICABLE AS PART OF THE SCOPE OF WORK FOR THIS PROJECT..
SMOKE COMPARTMENTALIZATION:
- NOT APPLICABLE.
FIRE ALARM SYSTEM:
- EXISTING TO REMAIN.
STANDPIPES:
- EXISTING TO REMAIN.
AREA NOT IN SCOPE
EGRESS PATH
BUILDING EXIT
OCCUPANT LOAD
FIRE - 1 HOUR
FIRE - 2 HOUR
FIRE / SMOKE - 1 HOUR
FIRE / SMOKE - 2 HOUR
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
AREA
OCC. LOAD
FACTOR IN SF
OCC. LOADOCCUPANT ROOM TYPEROOM
15 NET A238 145 SF 10
OCCUPANT LOAD PER NFPA 101-2021
PER TABLE 7.3.1.2
TRAVEL DISTANCE: 42'-9"
TRAVEL DISTANCE: 69'-9"
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:1
A
M
LIFE SAFETY PLANS - BUILDING 4
ECO 04 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
GI003
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 4 - SECOND FLOOR1
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 4 - PENTHOUSE3
LIFE SAFETY REQUIREMENTS
LIFE SAFETY LEGEND
RATED PARTITIONS & BARRIERS
N
N
1/16" = 1'-0"
TEMPORARY LIFE SAFETY PLAN - BLDG 4 - SECOND FLOOR2
A5
A1 A13A A13
A13B
A9
EL-1
A8
A6
A2E A1E
A1A
EL-2
UP
A B C D E F G H J K L M N P Q R S T
B3B
B3E
EEWS
B3 B3F B3A B0-C3
B2E
B2A B2 C12C C12B C12
C12A
C11
EEWS
C0-C2
C11A
C10 C10F
C11E
DN
C9 C9A
C9B
C9D
C9H UP
C9G
A
A1-C1
A101BB102
A101A
A101 A101C A160
A135
A132
EL-1
A128 A127
A129
A1-C1A102E A101E
EL-2
A B C D E F G H J K L M N P Q R S T
A130P
A130B A130A
C139B
B123A B123B C139A
A130
B123 C139C
B123C C139
C1-C3
C140A
A131
B122
B114C B115
B114D B114B
B117
B111E B1-C1
DN UP
B120 B119
B126
B111 B110 B114A B114 B113
B112
B107A B108
DN
DN
B107 C155
B109
B106 B105 B104
B103
C157A
C157
C159 C158 C156
C154 C155A
B123D
B120F
B124 C138
C141F B125
B126A B126B C136A
C136 C143
C144
C1-C1
C150P
C153 C152 C151
C150E
C150 C149 C148D
C148C
C145
C147E
C136B C142
C148A
UP DN C147
C148 C148B
C137 C141
C140
B
B P
C
A
A1-C1
A101BB102
A101A
A101 A101C A160
A135
A132
EL-1
A128 A127
A129
A1-C1A102E A101E
EL-2
H J K L M N P
A130P
A130B A130A
C139B
C139A
A130
C139C C139
C1-C3
C140A
A131
DN
DN
C155
C157A
C157
C159 C158 C156
C154 C155A
C138
C141F
C136A
C136 C143
C144
C1-C1
C150P
C153 C152 C151
C145
C136B C142
UP DN
C137 C141
C140
TRAVEL DISTANCE: 62'-2"
TRAVEL DISTANCE: 77'-6"
FIRE - 1 HOUR
FIRE - 2 HOUR
FIRE / SMOKE - 1 HOUR
FIRE / SMOKE - 2 HOUR
AREA NOT IN SCOPE
EGRESS PATH
BUILDING EXIT
OCCUPANT LOAD
NFPA 101-2021 EDITION
CONSTRUCTION TYPE: (NFPA-220 TABLE 4.1.1 IN ACCORDANCE WITH THE VA FIRE PROTECTION
DESIGN MANUAL 2.1): TYPE II (000)
BUILDING HEIGHT: (TABLE 19.1.6.1)
2 STORIES, 24'-9" HEIGHT
BUILDING AREA:
AREA LIMITATION: NOT APPLICABLE (NFPA-101)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
FIRE RESISTANCE RATINGS (NFPA-220 SECTION 5.1 IN ACCORDANCE WITH THE VA FIRE
PROTECTION DESIGN MANUAL 2.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
CHAPTER 39: EXISTING BUSINESS OCCUPANCY
OCCUPANT LOADS (NFPA-101 TABLE 7.3.1.2):
• BASEMENT FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• FIRST FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SECOND FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
ELEVATOR HOISTWAYS (NFPA-101 TABLE 7.3.1.2)
SHAFTS MINIMUM 1-HOUR RATING (NFPA 7.1.3.2.1)
• 3-STORIES OR LESS IS 1-HOUR RATING FOR SHAFT ENCLOSURE.
DEAD END CORRIDOR MAXIMUM DISTANCE: 50' (NFPA-101 39.2.5.2) N/A
MAXIMUM COMMON PATH OF TRAVEL: 100' (NFPA-101 19.2.5.5) N/A
MAXIMUM TRAVEL DISTANCE: 200' (NFPA-101 19.2.6.2.1) N/A
CORRIDOR MINIMUM FIRE RATING: 0 HR (NFPA-101 39.3.6.1 EXCEPTION 3) N/A
ALL EXIT DOORS PROVIDED ARE EXISTING AND NOT PART OF THIS SCOPE OF WORK.
STAIR WIDTH PROVIDED IS EXISTING AND NOT PART OF THIS SCOPE OF WORK.
PROTECTED AREAS:
- NOT APPLICABLE AS PART OF THE SCOPE OF WORK FOR THIS PROJECT..
SMOKE COMPARTMENTALIZATION:
- NOT APPLICABLE.
FIRE ALARM SYSTEM:
- EXISTING TO REMAIN.
STANDPIPES:
- EXISTING TO REMAIN.
ASSEMBLY - LESS CONCENTRATED
USE, WITHOUT FIXED SEATING
AREA
OCC. LOAD
FACTOR IN SF
OCC. LOADOCCUPANT ROOM TYPEROOM
BUSINESS 100
15 NET
A135
A9
145 SF
146 SF
OCCUPANT LOAD PER NFPA 101-2021
PER TABLE 7.3.1.2
TRAVEL DISTANCE: 52'-4"
TRAVEL DISTANCE: 76'-1"
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:1
A
M
LIFE SAFETY PLANS - BUILDING 5
ECO 05 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
GI004
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 5 - BASEMENT1
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 5 - FIRST FLOOR2
RATED PARTITIONS & BARRIERS
LIFE SAFETY LEGEND
N
N
LIFE SAFETY REQUIREMENTS
1/16" = 1'-0"
TEMPORARY LIFE SAFETY PLAN - BLDG 5 - FIRST FLOOR3
A233
A202 A201 A257
A202E A201E
A227 A228 A228F
A229
EL-1
A230
A232
EL-2
A2-C1
DN
A B C D E F G H J K L M N P Q R S T
B223A B223B C236A C236B
B223 B223C C236 C236C
B222 B224
B221 B225
B215 B214C
B226
B215E
B214A B211E
B211 B210
B214 B213 B212 B209
B207A B208
B206
B205 B204 B203 C256 C255
C253A C253
C251 C252A
C254
C250 C249 C248 C247 C245C
C246 C245D
B217/B218 B219
B2-C1
B220F
DN
B220 B226A B226B
C240
C2-C1 C247E
C223A C233 C233B
C242 C241
C244E
C234 C238
C238F
DN
C239
C244 C245
C245B
C235 C237
B207 C252
B B
B
B P
C P
C 3 C
A
A B C D E F G H J K L M N P Q R S T
A B C D E F G H J K L M N P Q R S T
A
A233
A202 A201 A257
A202E A201E
A227 A228 A228F
A229
EL-1
A230
A232
EL-2
A2-C1
DN
H J K L M N P Q
C236A C236B
C236 C236C
C256 C255 C253A
C253
C251 C252A
C254
C250 C249 C248 C247
C240
C2-C1 C247E
C223A C233 C233B
C242 C241
C244E
C234 C238
C238F
DN
C239
C235 C237
C252
C P
C
TRAVEL DISTANCE: 70'-0"
A300
A303
NFPA 101-2021 EDITION
CONSTRUCTION TYPE: (NFPA-220 TABLE 4.1.1 IN ACCORDANCE WITH THE VA FIRE PROTECTION
DESIGN MANUAL 2.1): TYPE II (000)
BUILDING HEIGHT: (TABLE 19.1.6.1)
2 STORIES, 24'-9" HEIGHT
BUILDING AREA:
AREA LIMITATION: NOT APPLICABLE (NFPA-101)
BUILDING IS EQUIPPED WITH A FULLY AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT
FIRE RESISTANCE RATINGS (NFPA-220 SECTION 5.1 IN ACCORDANCE WITH THE VA FIRE
PROTECTION DESIGN MANUAL 2.1):
• COLUMNS: 0 HR
• BEAM, GIRDERS, TRUSSES: 0 HR
• FLOOR/CEILING ASSEMBLIES: 0 HR
• ROOF/CEILING ASSEMBLIES: 0 HR
• EXTERIOR NON-BEARING WALLS: 0 HR
• INTERIOR NON-BEARING WALLS: 0 HR
FIRE-RESISTIVE REQUIREMENTS:
• NON COMBUSTIBLE MATERIALS FOR STRUCTURAL FRAME, FLOORS, ROOF DECK, EXTERIOR
NON-BEARING WALLS, INTERIOR NON-BEARING WALLS (U.N.O. AT EXTERIOR)
CHAPTER 19: EXISTING HEALTHCARE OCCUPANCY
OCCUPANT LOADS (TABLE 7.3.1.2):
• BASEMENT FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• FIRST FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SECOND FLOOR HEALTHCARE USE = EXISTING LOAD DOES NOT CHANGE
• SEE TABLE BELOW FOR ROOMS AFFECTED BY CONSTRUCTION.
ELEVATOR HOISTWAYS (NFPA TABLE 7.3.1.2)
SHAFTS MINIMUM 1-HOUR RATING (NFPA 7.1.3.2.1)
• 3-STORIES OR LESS IS 1-HOUR RATING FOR SHAFT ENCLOSURE.
DEAD END CORRIDOR MAXIMUM DISTANCE: 30' (NFPA-101 19.2.5.3) N/A
MAXIMUM COMMON PATH OF TRAVEL: 100' (NFPA-101 19.2.5.5) N/A
MAXIMUM TRAVEL DISTANCE: 200' (NFPA-101 19.2.6.2.1) N/A
CORRIDOR MINIMUM FIRE RATING: 0 HR (NFPA-101 19.3.6.1 EXCEPTION 3) N/A
ALL EXIT DOORS PROVIDED ARE EXISTING AND NOT PART OF THIS SCOPE OF WORK.
STAIR WIDTH PROVIDED IS EXISTING AND NOT PART OF THIS SCOPE OF WORK.
PROTECTED AREAS:
- NOT APPLICABLE AS PART OF THE SCOPE OF WORK FOR THIS PROJECT..
SMOKE COMPARTMENTALIZATION:
- NOT APPLICABLE.
FIRE ALARM SYSTEM:
- EXISTING TO REMAIN.
STANDPIPES:
- EXISTING TO REMAIN.
AREA NOT IN SCOPE
EGRESS PATH
BUILDING EXIT
OCCUPANT LOAD
FIRE - 1 HOUR
FIRE - 2 HOUR
FIRE / SMOKE - 1 HOUR
FIRE / SMOKE - 2 HOUR
AREA
OCC. LOAD
FACTOR IN SF
OCC. LOADOCCUPANT ROOM TYPEROOM
BUSINESS 100 A232 145 SF 2
OCCUPANT LOAD PER NFPA 101-2021
PER TABLE 7.3.1.2
TRAVEL DISTANCE: 42'-4"
TRAVEL DISTANCE: 69'-2"
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 12/31/2023
ENGR REG. NO. EXP. 12/31/2023
STRUCTURAL ENGINEER
STAND STRUCTURAL ENGINEERING, INC.
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
KS A-930
KS E-2586
Drawing Number
Building Number
SPUR #: 1794.09
ELEVATOR CONSULTANT
LERCH BATES
2001 BRYAN STREET, SUITE 1930
DALLAS, TX 75201
(972) 232-7267 COLMERY-O'NEIL VA MED CENTER
2200 SW GAGE BLVD
TOPEKA, KS 66622
/1
/2
:1
:1
A
M
LIFE SAFETY PLANS - BUILDING 5
ECO 06 110DLK
BID DOCUMENTS
REPAIR LIFE SAFETY/ FCA
DEFICIENCIES
12/15/2021
589A5-21-101
GI005
1/16" = 1'-0"
LIFE SAFETY PLAN - BLDG 5 - SECOND FLOOR1
1/16" = 1'-0"
LIFE SAEFTY PLAN - BLDG 5 - PENTHOUSE3
LIFE SAFETY REQUIREMENTS
LIFE SAFETY LEGEND
RATED PARTITIONS & BARRIERS
N
N
1/16" = 1'-0"
TEMPORARY LIFE SAFETY PLAN - BLDG 5 - SECOND FLOOR2
JJ
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A
B
CRAWL SPACE
CRAWL SPACE
C
UP
UP
B09A
B08
CRAWL SPACE
B08F B09 B0-C1 A0-C1
B07E
B07 B06 B05 B04 B03 A02
A2E A01E
A01
C0-C1
B09B
OPEN TO BELOW
DN A11
A12F
C17 C17F
A0-S1 A13
C15 A14
A0-E9 C15A
C17A
E
C18
CRAWL SPACE
F
C19E
A24A A24 C23 C22 C21 C20
G
A01A A24B C19
TO MECHANICAL
ACCESS PIT,
OPEN TO EXTERIOR
H
C15B
C17B UP
D1
D
CRAWL SPACE
CRAWL SPACE
J
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
A137
A
B127A
A138 B127 B128 C154 C155
A136
C153 A1-C3
B126 B129
C152
A136A B126A
A138A
B129A
B125A
B121
B119 B120 B121A
B121E
B119A B1-C3
B123
B115E B1-C1
B115
B118 B117
B116A B114
A101A C173
B113
DN
DN
B112 B110
C175 C174
C175A C174A
C172
H
B116 B1-C4 B108
B109
B107
B106 B105 B104
B122 B1-S3
UP UP
B131 B134
A1-C4
A101
A103E
A103
A102E
A102
A143 A144
A1-C1
C1-3
G
A145
B1-C2
B132 B133
A1-E9 A140
A1-C2
C143A
C143B C143
C146B
C171
C147 C148 C168
C170 C169A C169
B125
B125F
B132A A1-S1
C144 A141
C142
C142A
C145 C146
C146C
F
C146A C160
C149 C161
C170E C163A C1-C1
C163E
UP A139 C144A
C1-S2
UP UP
B130
C150
UP
C162
C163 C164
C165
C166 C167
E
C158F C158 DN
D1
D
C1-C2 C151 C157
C
DN
DN
C156
B
J
D
E
F
13 14 1514.5
DA
1. INSTALL NEW PIPE ROUTING IN CRAWL SPACE AREA DUE TO THE INSTALLATION OF THE NEW
ELEVATOR. COORDINATE ALL PIPING RELOCATIONS WITH PLUMBING DRAWINGS.
2. ONCE NEW PIPING HAS BEEN INSTALLED, CONTRACTOR TO CUT OVER OF PIPING TO THE
EXISTING CONNECTIONS TO THE BUILDING AND EQUIPMENT SYSTEMS. THIS WORK WILL NEED TO
BE DONE ON NIGHTS OR WEEKENDS TO LIMIT THE DOWN TIME OF THE SYSTEM.
3. AFTER NEW PIPING HAS BEEN INSTALLED AND CUT OVER, PIPING SYSTEM TO BE TESTED AND
CONFIRM SYSTEM IS RUNNING PROPERLY. ONCE PLUMBING SYSTEM IS CONFIRMED, THE
CONTRACTOR CAN DEMO THE EXISTING PIPING AND REMOVE FROM THE CRAWL SPACE.
4. DURING THE PIPING DEMO WORK, THE CONTRACTOR CAN BEGIN THE REMOVAL OF THE CRAWL
SPACE DIRT AREA FOR THE INSTALLATION OF THE NEW ELEVATOR PIT.
5. PROVIDE SAFETY SHORING AS NEEDED IN THE PIT AREA AGAINST THE DIRT THAT WILL REMAIN.
1. PROVIDE ICRA BARRIERS AROUND INTERIOR CONSTRUCTION AREA PRIOR TO DEMOLITION WORK
AT THIS FLOOR.
2. INSTALL 2-HOUR RATED FIRE BARRIER AROUND SHAFT AREA TO MAINTAIN SEPARATION OF
SHAFT WORKING AREA FROM FUNCTIONAL AREAS OF THE BUILDING.
3. DEMO EXISTING CEILING EXTENTS AS NEEDED FOR REMOVAL OF MECHANICAL DUCTWORK AND
PIPING AT THE NEW ELEVATOR INSTALLATION AREA.
4. DEMO BASEMENT FLOOR SLAB AREA FOR NEW ELEVATOR INSTALLATION. CONTRACTOR TO
PROVIDE THE NECESSARY SAFETY PRECAUTIONS FOR STRUCTURAL SHORING, GUARDRAILS,
ETC. FOR REMOVAL OF THE SLAB AND PROTECTION OF A FLOOR OPENING.
5. CONTRACTOR TO INSTALL STRUCTURAL REINFORCEMENTS AT THIS TIME.
CRAWL SPACE FLOOR - PHASING NOTES:
BASEMENT FLOOR - PHASING NOTES:
PHASING NOTES
1. PROVIDE ICRA BARRIERS AROUND INTERIOR CONSTRUCTION AREA PRIOR TO DEMOLITION WORK
AT THIS FLOOR.
2. DEMO EXISTING EXTERIOR WALL ON FIRST FLOOR FOR CONSTRUCTION ACCESS TO AND FROM
WORK AREA IN THE BUILDING AS SHOWN ON THE PLAN. PROVIDE CONSTRUCTION BARRIERS
AROUND THIS AREA INTERIOR AND EXTERIOR.
3. INSTALL TEMPORARY 2-HOUR RATED FIRE BARRIER AROUND SHAFT AREA TO MAINTAIN
SEPARATION OF SHAFT WORKING AREA FROM FUNCTIONAL AREAS OF THE BUILDING.
4. DEMO EXISTING CEILING EXTENTS AS NEEDED FOR REMOVAL OF MECHANICAL DUCTWORK AND
PIPING AT THE NEW ELEVATOR INSTALLATION AREA.
5. DEMO FIRST FLOOR SLAB AREA FOR NEW ELEVATOR INSTALLATION. CONTRACTOR TO PROVIDE
THE NECESSARY SAFETY PRECAUTIONS FOR STRUCTURAL SHORING, GUARDRAILS, ETC. FOR
REMOVAL OF THE SLAB AND PROTECTION OF A FLOOR OPENING.
6. CONTRACTOR TO INSTALL STRUCTURAL REINFORCEMENTS AT THIS TIME.
7. DEMO EXTENTS OF ADJACENT STORAGE CLOSET AREA WHICH INCLUDES CORRIDOR WALL AND
DOOR AND FRAME SYSTEM.
FIRST FLOOR - PHASING NOTES:
TEMPORARY 2-HOUR RATED FIRE BARRIER. BARRIER TO BE INSTALLED PRIOR TO COMMENCEMENT
OF DEMOLITION OF CONCRETE SLAB AREA PER FLOOR FOR NEW ELEVATOR SHAFT.
NEED TO MAINTAIN SEPARATION OF SPACE…
This is the start of the file's text. The full file is on GovTribe.