About this file
This document includes an appendix outlining the scope of work for upgrading the Physical Access Control System (PACS) at multiple Department of Veterans Affairs medical facilities. The contractor will be responsible for reprogramming existing hardware, installing new hardware, and upgrading the software as approved to complete the PACS upgrade across 175 doors at various facility locations. The contractor must provide all necessary labor, equipment, transportation, and materials to perform the procurement, installation, and provide annual support. Key facilities include buildings at the Captain James A. Lovell Federal Health Care Center and community-based outpatient clinics in Evanston, Kenosha, McHenry, and regional offices in Gurnee, Illinois. The contract type is not specified but appears to be a firm-fixed price contract based on the scope of work defined.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| PACS Appendix A Clean.xlsx | XLSX spreadsheet | |
| 36C25222Q0559 0003.docx | DOCX document | |
| 36C25222Q0559 0002.docx | DOCX document | |
| Site Map.pdf | ||
| 36C25222Q0559 0001.docx | DOCX document | |
| P07 - Lake County WD 2015-4935 (Rev 19) dated 03.15.2022.pdf | ||
| 36C25222Q0559.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Phase
| Phase | Count | Timeline | ||
| 1 | 78 | 60 days | Old Doors | 78 |
| 2 | 5 | 30 days | ||
| 3 | 41 | 60 days | ||
| 4 | 46 | 60 days | New Doors | 92 |
| 5 | 5 | TBD | ||
| Total | 175 | |||
| Count | Door type | |||
| 4 | IT Hallway door | |||
| 28 | IT OFFICE | |||
| 116 | IT ROOM COMMUNICATION CLOSET | |||
| 4 | IT ROOM SERVER ROOM | |||
| 6 | IT Cabinet | |||
| 9 | IT STOREROOM | |||
| 5 | New Construction | |||
| Count | Equip | |||
| 146 | Cameras | |||
| 126 | T/H monitoring | |||
| 4 | Raised floor monitoring |
Doors
| Campus | Phase | Room | Local Room Name | Doors | Security Areas | Factor |
| 1-West | 3 | 132-1-A | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 195-1-A | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 195-1-B | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 37-1-A | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 4 | GATE1-A | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 4 | GATE2-B | IT Cabinet | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3E-R | IT Hallway door | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3E-T | IT Hallway door | 1 | Controlled - 1 | 1F |
| 1-West | 1 | 133-3E-U | IT Hallway door | 1 | Controlled - 1 | 1F |
| 1-West | 1 | 133-3E-V | IT Hallway door | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-E | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1007-2-C | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1017-1-D | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1017-1-E | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1017-1-F | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1017-3-B | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1017-3-C | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-F | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 1 | 133-3E-G | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 1 | 133-3E-H | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-I | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-J | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-K | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-L | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-M | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-N | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-O | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 3 | 133-3E-P | IT OFFICE | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 135-2-A | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-B | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-C | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-D | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-E | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-F | IT OFFICE | 1 | Controlled - 1 | 1F |
| 1-West | 4 | 135-2-G | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 1523-1-D | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 237-1-D | IT OFFICE | 1 | Controlled - 1 | 1F |
| 2-East | 4 | 81H-1-B | IT OFFICE | 2 | Controlled - 1 | 1F |
| 2-East | 4 | 1007-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1007-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1007-2-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1017-1-A | IT ROOM COMMUNICATION CLOSET | 2 | Controlled - 1 | 2F |
| 4 | 1017-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F | |
| 2-East | 4 | 1017-1-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1017-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1017-3-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 11-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 1-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 1-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-0-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-0-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-3-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 131-4-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0C-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0D-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0D-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | IT ROOM COMMUNICATION CLOSET | |||||
| 1-West | 1 | 133-0D-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0E-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0E-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0E-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0F-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0F-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1A-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1B-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1C-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1D-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1D-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1D-D | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1E-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1E-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1E-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1F-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-1F-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2A-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | IT ROOM COMMUNICATION CLOSET | |||||
| 1-West | IT ROOM COMMUNICATION CLOSET | |||||
| 1-West | 1 | 133-2D-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2D-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2D-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2D-D | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2E-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2E-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2F-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-2F-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3D-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3D-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3D-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3F-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3F-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-4A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-4B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-1A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-1A-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-1B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-2A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-2A-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-2B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-3A-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-3A-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-3B-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 135-0-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 135-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 135-2-H | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 138-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 1-3-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 140-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 152-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1523-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1523-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 1523-1-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 187-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 188-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 196-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 201-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 202-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 205-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 206-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 237-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 237-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 237-1-C | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | IT ROOM COMMUNICATION CLOSET | |||||
| 1-West | IT ROOM COMMUNICATION CLOSET | |||||
| 1-West | 3 | 3-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | IT ROOM STORAGE | |||||
| 1-West | 3 | 32-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 3-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 4 | 36-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 4-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 4-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 4-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 43H-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 43H-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 46-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 46-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 6-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 6-1-B | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 66-0-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 66-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 66-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 7-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 7-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 2-East | 4 | 81H-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 9-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 92-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 9-2-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 3-Remote | 2 | CFM-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | IT ROOM | |||||
| 3-Remote | 2 | ECBOC-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 3-Remote | 2 | EVET-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 3-Remote | 2 | KCBOC-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 3-Remote | 2 | MCBOC-1-A | IT ROOM COMMUNICATION CLOSET | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-0B-A | IT ROOM SERVER ROOM | 1 | Controlled - 1 | 2F |
| 1 | 133-0B-B | IT ROOM SERVER ROOM | 1 | Controlled - 1 | 2F | |
| 1-West | 1 | 133-3E-D | IT ROOM SERVER ROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0A-C | IT ROOM SERVER ROOM | 2 | Controlled - 1 | 2F |
| 1-West | 3 | 133-3E-A | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 3 | 133-3E-B | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 133-3E-C | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0A-A | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0A-B | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0B-A | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0B-B | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0B-C | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 1 | 134-0C-A | IT STOREROOM | 1 | Controlled - 1 | 2F |
| 1-West | 5 | 48-1-A | New Construction | 1 | Controlled - 1 | 2F |
| 1-West | 5 | 48-2-A | New Construction | 1 | Controlled - 1 | 2F |
| 1-West | 5 | 48-3-A | New Construction | 1 | Controlled - 1 | 2F |
| 1-West | 5 | 5-1-A | New Construction | 1 | Controlled - 1 | 2F |
| 1-West | 5 | 5-2-A | New Construction | 1 | Controlled - 1 | 2F |
| Total | 175 |
Address
| Building number | Name | Street Address | City | State | Zip |
| 152 | Bldg. 152 | 198 Preble Ave | Great Lakes | IL | 60088 |
| 237 | USS Fisher Clinic, Bldg. 237 | 2410 Sampson Street | Great Lakes | IL | 60088 |
| 1007 | USS Tranquillity, Bldg. 1007 | 2430 Illinois Street | Great Lakes | IL | 60088 |
| 1017 | USS Osborne Dental Clinic, Bldg. 1017 | 3440 Ohio Street | Great Lakes | IL | 60088 |
| 1523 | USS Red Rover, Bldg. 1523 | 1020 11th Ave | Great Lakes | IL | 60088 |
| 3452 | Bldg. 3452 | 2650 Green Bay Road | Great Lakes | IL | 60088 |
| 43H | Bldg. 43H | 310 B Street | Great Lakes | IL | 60088 |
| 81H | Bldg. 81H | 510 B Street | Great Lakes | IL | 60088 |
| CFM | Construction & Facilities Management Regional Office | 1425 Tri-State Parkway, Suite 140 | Gurnee | IL | 60031 |
| ECBOC | Evanston CBOC | 1942 Dempster Street | Evanston | IL | 60202 |
| Evet | Evanston Vet Center | 1901 Howard St | Evanston | IL | 60202 |
| KCBOC | Kenosha CBOC | 8207 22nd Avenue | Kenosha | WI | 53140 |
| Main Facility | Captain James A. Lovell Federal Health Care Center | 3001 Green Bay Road | North Chicago | IL | 60064 |
| MCBOC | McHenry CBOC | 3715 Municipal Drive | McHenry | IL | 60050 |