This is a VOC Emission Test Certificate issued by Berkeley Analytical for Clear Armor LLC's Clear Armor Security Laminate - SL 15 / BR product, which is being considered for a Florida State Attorney Public Defender ballistic window film procurement. The product sample was tested on July 1, 2026, and certified on July 22, 2026, according to the California Department of Public Health CDPH/EHLB/Standard Method Version 1.2, 2017 (Emission testing method for CA Specification 01350). The testing evaluated the product's compliance with VOC emission standards across two exposure scenarios: school classroom and private office environments. Berkeley Analytical, an ISO/IEC 17025 accredited laboratory, conducted the analysis and confirmed that the Clear Armor Security Laminate met all acceptance criteria for both individual VOCs of concern and formaldehyde concentrations in both exposure scenarios.

The test results demonstrate that the product complies with formaldehyde limits of 9.0 micrograms per cubic meter and total VOC ranges of 0.5 mg/m³ across both classroom and private office settings. The Clear Armor Security Laminate - SL 15 / BR product is recognized by major sustainability and building standards programs, including USGBC LEED Version 4/4.1, The WELL Building Standard v2, and ANSI/GBI 01-2019 Green Globes Assessment Protocol. Berkeley Analytical's certificate affirms that the measured VOC emissions from the tested sample met the acceptance criteria of the referenced standard, though the laboratory disclaims responsibility for any claims regarding products entered into commerce based on this test. The certificate was issued by Raja S. Tannous, Laboratory Director, and references detailed findings contained in Berkeley Analytical report 1582-001-01A-Jul2226.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMPLIANCE TESTED by berkeley analytical

VOC Emission Test Certificate

Product Name: Clear Armor Security Laminate - SL 15 / BR

Product Sample Information Certificate Information

Company: Clear Armor LLC Certificate No: 260722-04

Company Website: www.clear-armor.com Certified By:

Product Type: Window Treatments Raja S. Tannous, Laboratory Director

Date Produced: June 30, 2026 Date: July 22, 2026

Reference Standard & Modeling Scenario: California Department of Public Health CDPH/EHLB/Standard Method Version 1.2, 2017 (Emission testing method for CA Specification 01350)

Acceptance Criteria and Results Demonstrating Compliance of Product Sample to Referenced Standard:

Exposure Scenario1 Individual VOCs of Concern2 Formaldehyde3 TVOC4

Criterion Compliant? Criterion Compliant? Range

School Classroom ≤½ Chronic REL YES ≤9.0 µg/m3 YES ≤ 0.5 mg/m3

Private Office ≤½ Chronic REL YES ≤9.0 µg/m3 YES ≤ 0.5 mg/m3

Sample Coverage5: Not applicable

1. Exposure scenarios and product quantities for classroom & office are defined in Tables 4-2 – 4-5 (CDPH Standard Method V1.2-2017)

2. Maximum allowable concentrations of individual target VOCs are specified in Table 4-1 (ibid.)

3. Maximum allowable formaldehyde concentration is ≤9 µg/m3, effective January 1, 2012; previous limit was ≤16.5 µg/m3 (ibid.)

4. Informative only; predicted TVOC Range in three categories: ≤0.5 mg/m3, >0.5 – 4.9 mg/m3, and ≥5.0 mg/m3

5. Informative and applicable only to tests of wet-applied products; grams of sample applied per square meter of substrate

Standards & Codes Recognizing CDPH Standard Method V1.2 (partial list)

• USGBC LEED Version 4/4.1, BD&C, ID&C, Residential BD&C Multifamily

• The WELL Building Standard, WELL v2, Feature X06

• ANSI/GBI 01-2019 Green Globes Assessment Protocol

Narrative: Clear Armor LLC selected a sample representative of its Clear Armor Security Laminate - SL 15 / BR product and submitted it on July 1, 2026 for testing. Berkeley Analytical measured and evaluated the emissions of VOCs from this sample following CDPH/EHLB/Standard Method V1.2-2017. The results of the test are presented in Berkeley Analytical report, 1582-001-01A-Jul2226.

Berkeley Analytical is an independent testing laboratory specializing in the analysis of organic chemicals emitted by and contained in building products, finishes, furniture, and consumer products. We are an ISO/IEC 17025 accredited laboratory (IAS, TL-383); all standards used in performing this test are in Berkeley Analytical’s scope of accreditation.

DISCLAIMER: THIS CERTIFICATE OF COMPLIANCE AFFIRMS THAT: 1) A SAMPLE OF THE LISTED PRODUCT WAS TESTED ACCORDING TO THE REFERENCED STANDARD;

2) THE MEASURED VOC EMISSIONS FROM THE SAMPLE WERE EVALUATED FOR THE DEFINED EXPOSURE SCENARIO(S); AND 3) THE RESULTS MEET THE ACCEPTANCE CRITERIA OF THE REFERENCED STANDARD(S). BERKELEY ANALYTICAL IS NOT RESPONSIBLE FOR ANY CLAIMS REGARDING A PRODUCT OR PRODUCTS ENTERED INTO COMMERCE THAT MAY BE BASED ON THIS TEST. BERKELEY ANALYTICAL PROVIDES THIS CERTIFICATE OF COMPLIANCE “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PURPOSE.

©2019 Berkeley Analytical, 815 Harbour Way South, Suite 6, Richmond, CA 94804 / 510-236-2325 / www.berkeleyanalytical.com

FC17B.3

https://www.iasonline.org/wp-content/uploads/2017/05/TL-383-Scope.pdf

File details come from the government source that posted it. Updated .