Other_Drawing A4.02.pdf
PDF 977 KB Posted
- Attached to
- Automatic Watering System for Large Animal Housing Area Federal contract opportunity
- Solicitation number
- FDA-SSN-123260
About this file
This document appears to be a detailed drawing and specifications for renovations to Building 62 at the FDA Jefferson Laboratories facility. The drawings provide enlarged floor plans, elevations, and construction details for the large animal holding areas, including requirements for trench drains, sloped flooring, stainless steel wall protection, and door specifications. The drawings reference a related federal contract opportunity, Solicitation Number FDA-SSN-123260, for an Automatic Watering System for the Large Animal Housing Area. This appears to be a pre-solicitation notice, providing details on the planned requirements for an upcoming contract to install an automated watering system for the renovated large animal holding rooms described in the construction drawings.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FDA-SSN-123260.pdf | ||
| Other_Drawing A1.01.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F.E .C
A B C DX
71'-6" 6" 8'-5"
A4.02
A2
LARGE
HOLDING
BEHAVIOR
LAB/HOLDING
LRG
BREEDING
LRG HOLD
F2
SLOPE
SLOPE
CLEAN CLEAN DIRTY
K2
A11
A4.02
SLOPE
SLOPE
SLOPE
SLOPE
NHP
HOLDING
LRG
FARROW
SLOPE
SLOPE
C L
E A
R
C L
E A
R
C L
E A
R
SLOPE
SLOPE
152A
152B
151B151A
150A 150B
149B
149A
M .O
M .O
M .O
M .O
SLOPE
SLOPE
A4.02
A2
Sim
A4.02
A3
FULL LENGTH SLOPING
TRENCH AND GRATE.
TYP. AT ALL HOLDING
ROOMS
INFILL AT DOOR DEMO
6B
6C
6B
6B
6B
6B
6B
6B
6B
6B
6B
6B
6B5
8'-4" 1'-4"
/2
DOOR IN EXISTING
MASONRY OPENING
DOOR IN EXISTING
MASONRY OPENING DOOR IN EXISTING
MASONRY OPENING
DOOR IN EXISTING
MASONRY OPENING
DOOR IN EXISTING
MASONRY OPENING
DOOR IN NEW
MASONRY OPENING
TYP HOLDING ROOM ELEVATIONS
6B
C4
INFILL WITH DOUBLE WYTH
8" CMU REFER TO A9.01
DETAIL G4 AND A9.02 H1
FOR SIMILIAR CONDITION.
EXTEND LINTEL FOR NEW
OPENING LOCATION
6B
6B
141A 141B
143B143A
A14
A4.02
SimTYP.
6B
6B
C1
C L E
A R
/4
PROVIDE SMOOTH
TRANSISTION
BETWEEN
CORRIDOR AND
FINISHES - TYP.
EPOXY FLOORING SELF
COVE BASE - TURN UP
WALL 8"
A11
A4.02
STAINLESS STEEL
WALL PROTECTION
RAIL
RETURN VENTS -
COORD WITH MEP
CONTINUOUS TRENCH DRAIN
2" 4'-0" 2"
CAGE WASH WATER
SUPPLY/FLUSHING CONTROL
PANEL - COORDINATE WITH MEP
EXISTING CMU WALL WITH NEW
FINISHES
STAINLESS STEEL DOOR AND
FRAME W/ PROTECTION PANEL
LEVER PROTECTION AND RED
FILM GLASS AT DOOR LITE - SEE
HARDWARE SPECIFICATIONS
STAINLESS STEEL
WALL PROTECTION
RAIL
*ALL HOLDING ROOMS ARE SIMILIAR CONTINUOUS TRENCH DRAIN
EXISTING CMU WALL WITH NEW
FINISHES
STAINLESS STEEL DOOR AND
FRAME W/ PROTECTION PANEL
LEVER PROTECTION AND RED
FILM GLASS AT DOOR LITE - SEE
HARDWARE SPECIFICATIONS
MECHANICAL/STRUCTURAL
CHASE/NOISE ISOLATION
TRENCH SPRAY NOZZLE
SLOPED CONCRETE FLOOR
TOPPING
EXISTING CONCRETE
FLOOR
STEEL C JOIST
SOUND ATTENUATING
INSULATION
CONCRETE MASONRY
UNIT - 2 COATS BLOCK
FILLER AND IPX FINISH
2 LAYERS OF WR GYPSUM BOARD
CEILING W/ 2 STAGE IPX FINISH
INSULATION RETAINER
SLOPE TRENCH TO DRAIN
GRATE - REF MEP
A4.02
A14
EXISTING
WALL PROTECTION RAIL
4"
SLOPE
TRENCH DRAIN COVER FLUSH
WITH FLOOR FINISH - REF
PLUMBING
NOTCH BACK UNDERLAYMENT
AS NECESSARY FOR FLUSH
TRENCH COVER INSTALLATION
TYPICAL TRENCH DRAIN
SUPPORT SYSTEM BY TRENCH
DRAIN MANUF.
WALL CONSTRUCTION - REF
PARTITION SCHEDULE
FLOOR DRAIN AND STRAINER
ASSEMBLY BEYOND
TRENCH SPRAY NOZZLE
TOPPING SLAB - SIM OR EQUAL
TO SIKA QUICK 1,000
8"
EXISTING FLOOR SLAB
(WHERE OCCURS)
TURN UP EPOXY FLOOR
COATING +/- 6" TO MATCH
EXISTING SLOPED BASE
DETAILS
4"4"
0"
4"
0"
4"4"
4"
0"
4"
TROUGH -1"
TROUGH (DRAIN) -3"
TROUGH -1"
5/8" / 12"
5/8" / 12"
B.O. DOOR THRESHOLD TO
BE FLUSH WITH COORIDOR
AND HIGH POINT OF HOLDING
ROOM
NOTE:
-TROUGH (DRAIN) SLOPES TO DRAIN
-DOOR THRESHOLDS ARE ASSUMED AT +4" TO BE FLUSH WITH
TOP OF TOPPING SLAB
-1"
0"
TROUGH
ROOM
DRAIN
SLOPE SLOPE
SLOPESLOPE SLOPE
-3" Copyright
Date
Title
Sheet No.
901 West Third Street Little Rock, Arkansas 72201 501.374.5300
Seal
Job No.
www.WERarch.com
SRQPNMLKJHGFEDCBA
A B C D E F G H J K L M N P Q R S
ARCHITECT
WER Architects/Planners
/1
/2
:0
:1
A
M
C U s e rs
\a s a n d e rs o n
\D o c u m e n ts \F
D A
ID
I2
.0
-F
D A
B u ild in g
C o n s t D o c s v a s a n d e rs o n
W E
.r v t
FDA Jefferson
Laboratories
BLDG. 62
RENOVATIONS
3900 NCTR Road, HFT_324
Jefferson, AR 72079
MEPFP ENGINEERS
Energy Engineering Consultants, Inc 10 Corporate Hill Dr Little Rock, AR 72205 501-244-0511
A4.02
ENLARGED VIEWS
03/24/22
FDAIDI21.01
OWNER
FDA
Jefferson Laboratories
OAGS - Field Operations Branch 3900 NCTR Road Jefferson, AR 72079
P ro je c t
N a m e
ISSUE FOR CONSTRUCTION
1/4" = 1'-0" G14
ENLARGED HOLDING
1/4" = 1'-0" A2
INTERIOR ELEV - PEN WALL
1/4" = 1'-0"
F2
INTERIOR ELEV - HOLDING TO DIRTY
1/4" = 1'-0" K2
INTERIOR ELEV - HOLDING TO CLEAN
1/2" = 1'-0" A11
TYPICAL WALL SECTION AT TOPPING SLAB HOLDING ROOM LOCATIONS
3" = 1'-0" A14
TRENCH DRAIN DETAIL
A6
TYPICAL HOLDING ROOM SLOPE LAYOUT
1/2" = 1'-0" A3
ENLARGED PLAN TRENCH SLOPE PLAN
No. Issue Date
File details come from the government source that posted it. Updated .