Oakland County Tower Modification R5.pdf

PDF 3 MB Posted

Attached to
MPSCS Oakland County, Pontiac Tower #1203 Tower Modification
Solicitation number
RFP-171-180000002872-1
Issued by
Oakland County, Michigan

About this file

This is a technical engineering drawing package prepared by EET, LLC for tower modifications to an Oakland County communications tower located at the Pontiac Social Services site in Michigan. The drawings detail modifications required for five sections of a 285-foot self-supporting tower, including converting X-bracing assemblies to C-shape assemblies in sections T5 (230-250 ft), T6 (210-230 ft), and T9 (160-170 ft), reinforcing diagonals in section T15 (50-70 ft), and reinforcing redundant horizontals in section T17 (0-30 ft). The 16-page drawing set, dated January/June 2018, includes detailed fabrication specifications, assembly details, and parts lists for all modification components.

The modifications require various galvanized steel angles, bolts, washers, nuts, and V-clamp assemblies. Key components include 120 5" V-clamps, multiple reinforcement angles ranging from 2"x2"x1/8" to 3"x3"x1/4", and hundreds of galvanized fasteners. The drawings emphasize critical safety notices regarding structural stability during modification work, requiring temporary bracing and adherence to TIA-322 and ASSE 10.48 standards for rigging plans. All steel must meet ASTM A-36 specifications with hot-dip galvanizing per ASTM A123, and field modifications must maintain minimum edge distances and coating requirements.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

MODIFICATION SUMMARY

SECTION

FROM (ft.) TO (ft.)

MODIFICATION DESCRIPTION SHEET NUMBER

T5 230 250 CONVERT TO C-SHAPE ASSEMBLY 14-16

T6 210 230 CONVERT TO C-SHAPE ASSEMBLY 11-13

T9 160 170 CONVERT TO C-SHAPE ASSEMBLY 8-10

T15 50 70 REINFORCE DIAGONAL 6-7

T17 0 30 REINFORCE REDUNDANT HORIZONTALS 4-5

NOTES:

1. MODIFICATIONS PER EET, LLC REPORT DATED 9-29-2018 SEE SHEET 1 FOR SUMMARY

2. THIS DOCUMENT DOES NOT CONSTITUTE A CONSTRUCTION DOCUMENT. A RIGGING PLAN IN ACCORDANCE WITH ASSE 10.48

AND TIA-322 SHALL BE CREATED PRIOR TO INSTALLATION OF THE MODIFICATIONS OUTLINED IN THIS DRAWING.

3. THE MODIFICATION MEMBER LENGTHS LISTED ARE BASED UPON THEORETICAL MEMBER DATA AND/OR FIELD MEASUREMENTS

OF MEMBERS. ADDITIONAL FIELD MODIFICATION OF MEMBERS MAY BE REQUIRED TO MATCH THE ORIGINAL AS BUILT

MEMBER LENGTHS. ADDITIONAL TOWER MODIFICATIONS MAY BE REQUIRED IF THE AS BUILT CONDITIONS DIFFER FROM THE

ASSUMPTIONS USED TO CREATE THE ORIGINAL EET, LLC REPORT REFERENCED ABOVE. FIELD CUTS MAY BE REQUIRED AS

INDICATED. FIELD DRILLING OF REINFORCEMENT HOLES IS REQUIRED. SEE FABRICATION SHEETS FOR THESE LOCATIONS.

FIELD DRILL HOLES IN REINFORCEMENT ANGLES ADJACENT TO THE TOWER LEG MAY BE MOVED TO AVOID CONFLICT WITH THE

TOWER LEG DIAGONAL ATTACHMENT PLATE. A MINIMUM OF 1" OF EDGE DISTANCE IS REQUIRED. SEE SHEET 3 FOR DETAILS.

4. ALL STEEL FABRICATION AND INSTALLATION SHALL BE DONE IN ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL

CONSTRUCTION MANUAL AND SPECIFICATIONS.

5. ALL STEEL ANGLE SHALL CONFORM TO ASTM A-36 STEEL SPECIFICATIONS - MIN. YIELD STRENGTH 36 KSI. ALL BOLTS, WASHERS AND NUTS SHALL CONFORM TO THE INDICATED ASTM SPECIFCATIONS.

6. STRUCTUAL MATERIAL SHALL NOT BE HEATED FOR STRAIGHTENING BENT OR WARPED MEMBERS.

7. THE FINISHED BOLT HOLE DIAMETERS SHALL NOT BE MORE THAN 1/16TH INCH LARGER THAN THE NOMINAL BOLT DIAMETER

UNLESS OTHERWISE NOTED.

8. ALL BOLTS SHALL BE NEW DOMESTIC UNLESS OTHERWISE NOTED.

9. ALL BOLTS SHALL BE TIGHTENED USING THE AISC TURN OF THE NUT METHOD

10. ALL STRUCTURAL STEEL SHALL BE HOT DIPPED GALVANIZED PER ASTM A123 SPECIFICATIONS AFTER FABRICATION.

11. FASTENERS AND HARDWARE SHALL BE GALVANIZED IN ACCORDANCE WITH ONE OF THE FOLLOWING:

ASTM A153, ASTM F2329, ASTM B695 CLASS 55

12. ALL FIELD INSTALLED HOLES SHALL BE DRILLED. ALL EXPOSED BARE OR DAMAGED MATERIAL SHALL BE COATED

WITH ZINGA OR SIMILAR MATERIAL. ANY DAMAGER

13. ALL INSTALLATION PROCEDURES AND SAFEGUARDS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER.

14. CONTACT THE ENGINEER IF ANY CHANGES, MODIFICATION OR ALTERATION OF THE INSTALLATION OUTLINED DUE

TO EXISTING CONDITIONS.

15. THE EXISTING STRUCTURE SHALL BE INSPECTED PRIOR TO MODIFICATION TO CONFIRM ITS CONDITION IS ACCEPTABLE

PER TIA REQUIREMENTS.

STATE OF

MICHIGAN

STATE OF

MICHIGAN

TOWER MODIFICATIONS

285' SS TOWER - PONTIAC SOCIAL SERVICES SITE

OAKLAND COUNTY

MASTER BOM

QTY.

PART NUMBER DESCRIPTION

120 10592 5" V-CLAMP

120 10599 ANGLE V-CLAMP WELDMENT

6 11005

UPPER REDUNDANT HORIZONTAL REINFORCEMENT 2" X 2" X 1/8" GALVANIZED STEEL ANGLE - SECTION T17

6 11006

LOWER REDUNDANT HORIZONTAL REINFORCEMENT 2" X 2" X 1/8" GALVANIZED STEEL ANGLE - SECTION T17

6 11008

DIAGONAL REINFORCEMENT 3" X 3" X 1/4" GALVANIZED STEEL ANGLE - SECTION T15

6 11009 T9 SECTION UPPER REINFORCEMENT ANGLE

6 11013 T6 LOWER REINFORCEMENT ANGLE

6 11016 T6 MIDDLE REINFORCEMENT ANGLE

6 11017 T6 UPPER REINFORCEMENT ANGLE

6 11018 T5 LOWER REINFORCEMENT ANGLE

6 11019 T5 MIDDLE REINFORCEMENT ANGLE

6 11020 T5 UPPER REINFORCEMENT ANGLE

3 11011

5/8" DIA. X 2" LONG A-325 GALVANIZED BOLT

3 11015

5/8" DIA. A-563 GRADE DH HEAVY HEX GALVANIZED NUT

3 11014

5/8" DIA. F436 GALVANIZED WASHER

18 11012

1/2" DIA. X 2" LONG GRADE 5 GALVANIZED BOLT

96 11004

1/2" DIA. X 4" LONG A-325 GALVANIZED BOLT - SECTION T17

144 11007A

1/2" DIA. X 6.5" LONG GRADE 5 GALVANIZED BOLT - SECTION T15

258 11002

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT

258 11003

1/2" DIA. F436 GALVANIZED WASHER

264 11034

3/8" DIA. X 1.00" LONG SAE GRADE 5 GALVANIZED BOLT

264 11032

3/8" DIA. F436 GALVANIZED WASHER

264 11033

3/8" DIA. GRADE B GALVANIZED HEX NUT

REVISION HISTORY

REV DESCRIPTION DATE

4 ADDED SHOP DIMENSION

6/12/2018

5 REPLACED 11007 WITH 11007A

6/13/2018

DETAIL BF

EDGE DETAILS NOTED IN THIS

VIEW ARE APPLICABLE

TO SECTIONS T9, T6 AND T6

DETAIL BG

TYPICAL ALL

CENTER BOLTS

DETAIL BH

TYPICAL BOTTOM DETAIL

DETAIL BJ

TYP. TOP DETAIL

SECTION BK-BK

TYPICAL ANGLE CROSS

SECTION DETAIL

BF

BG

BH

BJ

BK

BK

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

4 in AS DRAWN

6" MAX.

4 in AS DRAWN

6" MAX.

REPLACE EXISTING

CENTER BOLT

AT INTERSECTIONS

OF TOP "X" IN SECTION T9

AND ALL INTERSECTIONS

IN SECTION T6 AND T5

REUSE EXISTING SPACER

SEE SECTION PROFILES

FOR BOLT DETAILS

FIELD FABRICATION AND

INSTALLATION DETAILS

4 in AS DRAWN

6" MAX.

REINFORCEMENT

ANGLE

4 in AS DRAWN

6" MAX.

EXISTING ANGLE

REINFORCING

ANGLE

DETAIL A

UPPER REDUNDANT HORIZONTAL

DETAIL B

LOWER REDUNDANT HORIZONTAL

DETAIL G

CLAMP ASSEMBY

SEE SHEET 3

A

B

G

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

36'-0"

32'-8 3/4"

29'-11 1/4"

MODIFICATIONS REQURIED TO BE APPLIED TO SECTION T17:

FROM 0' AGL TO 30' AGL

ADD ANGLE REINFORCEMENT TO UPPER

AND LOWER REDUNDANT HORIZONTALS

ALL THREE FACES

CLAMP ON 2" X 2" X 1/8" ANGLE TO

REDUNDANT HORIZONTALS AS SHOWN WITH

A MAXIMUM CLAMP SPACING

OF 30" CENTER TO CENTER.

M a x i m u m s p a c i n g

REDUNDANT

HORIZONTAL

2" X 2" X 1/8"

GALVANIZED ANGLE

(3) CLAMPS MIN.

REDUNDANT HORIZONTAL

2" X 2" X 1/8" GALVANIZED ANGLE

(5) CLAMPS MINIMUM

UPPER REDUNDANT HORIZONTAL PARTS LIST PER KIT

DESCRIPTIONPART NUMBER

TOTAL

REQUIRED

THIS

SECTION

QTYITEM

ANGLE V-CLAMP WELDMENT105993051

5" V-CLAMP105923052

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT1100260103

1/2" DIA. F436 GALVANIZED WASHER1100360104

1/2" DIA. X 4" LONG A-325 GALVANIZED BOLT1100460105

2" X 2" X 1/8" STEEL A-36 STEEL ANGLE1100561T17-U-A

LOWER REDUNDANT HORIZONTAL PARTS LIST PER KIT

DESCRIPTIONPART NUMBER

TOTAL

REQUIRED

THIS

SECTION

QTYITEM

ANGLE V-CLAMP WELDMENT105991831

5" V-CLAMP105921832

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT110023663

1/2" DIA. F436 GALVANIZED WASHER110033664

1/2" DIA. X 4" LONG A-325 GALVANIZED BOLT110043665

2" X 2" X 1/8" A-36 STEEL ANGLE GALVANIZED1100661T17-L-A

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

SECTION T17 FROM BASE TO 30' AGL

UPPER REDUNDANT HORIZONTAL REINFORCEMENT

(6) KITS REQUIRED TOTAL

120 in CUT TO LENGTH

Lu Lu Lu Lu

58 in

Lu

Lu

1/4 in

1/4 in

T17-U-A

SECTION T17 FROM BASE TO 30' AGL

LOWER REDUNDANT HORIZONTAL REINFORCEMENT

(6) KITS REQUIRED TOTAL

T17-L-A

Lu SHALL NOT EXCEED 30 INCHES WHEN INSTALLED

Lu SHALL NOT EXCEED 30 INCHES WHEN INSTALLED

T17-U-A

T17-L-A

DETAIL H

SECTION J-J

SEE SHEET 5 FOR DETAILS

D D

H

J

J

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

MAX. SPACING

30" CENTER TO

CENTER

MODIFICATIONS REQURIED TO BE APPLIED TO SECTION T15:

FROM 50' TO 70' AGL

ADD ANGLE REINFORCEMENT TO DIAGONAL

CLAMP ON 3" X 3" X 1/4" ANGLE TO

DIAGONAL AS SHOWN WITH

A MAXIMUM CLAMP SPACING

OF 30" CENTER TO CENTER.

(12) CLAMP ASSEMBLIES

PER DIAGONAL

3" X 3" X 1/4"

ANGLE CLAMPED TO

EXISTING PIPE DIAGONAL

SEE SECTION J-J

30'-6 5/8"

28'-4 1/2"

SPACING SHALL

NOT EXCEED 30"

CENTER TO CENTER

IF ANGLE IS SPLIT. CENTER THE REINFORCEMENT ON EACH

ANGLE ON THE SPAN ABOVE AND BELOW THE REDUNDANT

HORIZONTAL

REDUNDANT

HORIZONTAL

VIEW BB-BB

T15 DIAGONAL REINFORCEMENT PARTS LIST

DESCRIPTION

PART

NUMBER

TOTAL QTY.

REQUIRED

FOR T15

SECTION

QTY. PER

DIAGONAL

ITEM

ANGLE V-CLAMP WELDMENT1059972+6111

5" V-CLAMP1059272+6112

1/2" DIA. X 6.5" LONG GRADE 5 GALVANIZED BOLT11007A144+12223

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT11002144+12224

1/2" DIA. F436 GALVANIZED WASHER11003144+12225

L3" X 3" X 1/4" REINFORCEMENT ANGLE1100861T15-L-D

BB

BB

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

Lu Lu Lu Lu Lu Lu Lu Lu Lu Lu

Lu SHALL NOT EXCEED 30 INCHES WHEN INSTALLED

LAYOUT ASSUMES 25" SPACING

SOME ADJUSTMENT TO Lu MAY BE REQUIRED TO CLEAR

REDUNDANT BRACING.

IT IS ACCEPTABLE TO PROVIDE THIS COMPONENT IN TWO 130" SEGMENTS

IF THIS COMPONENT IS SPLIT INTO TWO SEGMENTS AN ADDITIONAL HARDWARE WILL BE REQUIRED

ADDITIONAL HARDWARE IS SHOWN AS " + #" IN THE BOM LISTING BELOW.

THE LENGTH OF T15-L-D MAY REQUIRE FIELD TRIMMING TO ENSURE

THE MEMBER DOES NOT HIT THE ATTACHMENT PLATES AT EACH

END OF THE REINFORCEMENT ANGLE.

T15-L-D

21'-8"

MAY BE PROVIDED AS TWO SEGMENTS

SPLIT AT THE LOCATION OF THE REDUNDANT

HORIZONTAL

3 4 5

T15-L-D

130 in 130 in

IF ANGLE IS SPLIT ADD

ONE ADDITONAL CLAMP ASSEMBLY AT

THE END OF SEGMENT HERE

6 1/2 in

1 1/2 in

L

M

N

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

150 ft AGL

170 ft AGL

160 ft AGL

MODIFICATIONS REQURIED TO BE APPLIED TO SECTION T9:

FROM 160' TO 170' AGL

CONVERT EXISTING SINGLE 3" X 3" X 1/4" ANGLE X-BRACING TO

3" X 3" X 1/4" BACK TO BACK ANGLE X-BRACING

IMPORTANT NOTICE

REMOVAL OF THE EXISTING DIAGONAL BOLTS TO ALLOW ITS

REPLACEMENT WITH PART NUMBER 11016 WHEN INSTALLING

THE BACK TO BACK ANGLES WILL LEAD TO STRUCTURAL INSTABILITY.

THE REMOVAL OF THE SINGLE DIAGONAL BOLT WILL EFFECTIVELY

REMOVE THE ASSOCIATED DIAGONAL FROM THE STRUCTURE CREATING

THE INSTABILITY. ADDITIONAL TEMPORARY HORIZONTAL BRACING OR

ANOTHER SUPERVISED APPROACHED MUST BE INCORPORATED INTO

THE REPLACEMENT PROCEDURE OUTLINED IN THE RIGGING PLAN IN

ACCORDANCE WITH TIA-322.

27°

30°

DETAIL L

DETAIL M

TYPICAL SPACER DETAIL

DETAIL N

TYPICAL BRACE

TO LEG CONNECTION

SECTION T9 ASSEMBLY PARTS LIST

STATUSDESCRIPTIONPART NUMBERQTYITEM

NEWT9 SECTION UPPER REINFORCEMENT ANGLE1100961

NEW1/2" DIA. X 1-1/4" LONG GRADE 5 GALVANIZED BOLT11010602

NEW1/2" DIA. F436 GALVANIZED WASHER11003603

NEW1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT11002604

NEW5/8" DIA. X 2" LONG A-325 GALVANIZED BOLT1101135

NEW5/8" DIA. F436 GALVANIZED WASHER1101436

NEW5/8" DIA. A-563 GRADE DH HEAVY HEX GALVANIZED NUT1101537

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

IMPORTANT NOTICE

REMOVAL OF THE EXISTING DIAGONAL BOLTS WILL

LEAD TO STRUCTURAL INSTABILITY. ALL WORK

SHALL BE COMPLETED UTILIZING A RIGGING PLAN

IN ACCORDANCE WITH TIA-322 AND ASSE 10.48.

VIEWS THAT INCLUDE

THE EXISTING STRUCTURE

ARE REPRESENTATIONS

AND NOT TO SCALE

SEE PREVIOUS SHEET

FOR DETAIL LOCATIONS

1 7

5 6 7

EXISTING

DIAGONAL

5 6 7

IF THE BOLT HOLE IS OBSTRUCTED

IT MAY BE ABANDONED. IF ABANDONED

DRILL A NEW HOLE NO MORE THAN 8" FROM

THE CENTER BOLT.

13 3/4 in

AS DRAWN

3 1/2 in AS DRAWN

MAY EXTEND TO 8"

AS REQUIRED

1 3/4 in

REQUIRED

CENTER

BOLT

PART NUMBER 11009

SECTION T9 TOP REINFORCEMENT ANGLE

MATERIAL: 3" X 3" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

3 in

3 in

3/16 in

223 3/4 in

1 3/4 in

2 in

1 in

27 in

53 in

79 in

105 in

115 1/4 in

118 3/4 in

144 3/4 in

170 3/4 in

196 3/4 in

222 3/4 in

11/16 in THRU

9/16 in THRU

TYP. 10 PLACES

(2) FIELD DRILLED

(8) SHOP DRILLED

26 in

13 3/4 in

FIELD

DRILL

FIELD

DRILL

SECTION T6 PARTS LIST

DESCRIPTION

PART

NUMBER

QTYITEM

T6 UPPER REINFORCEMENT ANGLE1101761

T6 MIDDLE REINFORCEMENT ANGLE1101662

T6 LOWER REINFORCEMENT ANGLE1101363

1/2" DIA. X 2" LONG GRADE 5 GALVANIZED BOLT1101294

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT110021175

1/2" DIA. F436 GALVANIZED WASHER110031176

3/8" DIA. X 1.00" LONG SAE GRADE 5 GALVANIZED BOLT110341447

3/8" DIA. F436 GALVANIZED WASHER110321448

3/8" DIA. GRADE B GALVANIZED HEX NUT110331449

T

U

W

AA

AB

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

FACE VIEWS

TYPICAL ALL

THREE FACES

IMPORTANT NOTICE

REMOVAL OF THE EXISTING DIAGONAL BOLTS TO ALLOW

ITS REPLACEMENT WITH PART NUMBER 11016 WHEN

INSTALLING THE BACK TO BACK ANGLES WILL LEAD TO

STRUCTURAL INSTABILITY. THE REMOVAL OF THE SINGLE

DIAGONAL BOLT WILL EFFECTIVELY REMOVE THE

ASSOCIATED DIAGONAL FROM THE STRUCTURE CREATING

THE INSTABILITY. ADDITIONAL TEMPORARY HORIZONTAL

BRACING OR ANOTHER SUPERVISED APPROACHED MUST

BE INCORPORATED INTO THE REPLACEMENT PROCEDURE

OUTLINED IN THE RIGGING PLAN IN ACCORDANCE WITH TIA-322.

210` AGL

230` AGL

MODIFICATIONS REQURIED TO BE APPLIED TO SECTION T6:

FROM 210' TO 230' AGL

CONVERT EXISTING SINGLE 2" X 2" X 3/16" ANGLE X-BRACING TO

2" X 2" X 3/16" BACK TO BACK ANGLE X-BRACING

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

UPPER

MIDDLE

LOWER

EXISTING

DIAGONAL

26°

DETAIL T

CENTER CONNECTION

TYPICAL ALL 9 LOCATIONS

DETAIL U TYPICAL

DETAIL W TYPICAL

DETAIL AA

TYPICAL

DETAIL AB

TYPICAL

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

EXISTING

DIAGONAL

EXISTING

DIAGONAL

REINFORCEMENT

DIAGONAL

7 8 9

7 8 9

7 8 9

7 8 9

7 8 9

2 7/16 in TYP.

PART NUMBER 11017

T6 UPPER REINFORCEMENT ANGLE

MATERIAL: 2" X 2" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

PART NUMBER 11016

T6 MIDDLE REINFORCEMENT ANGLE

MATERIAL: 2" X 2" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

PART NUMBER 11013

T6 LOWER REINFORCEMENT ANGLE

MATERIAL: 2" X 2" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

DETAIL BC

TYPICAL ALL

CENTER BOLTS

DETAIL BD

TYP. ALL

OTHER BOLTS

BC

BD

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

2 in

2 in

3/16 in

152 5/8 in

146 3/4 in

139 7/8 in

2 in

2 in

3/16 in

2 in

2 in

3/16 in

1 1/4 in

1 in

26 in 26 in

26 in

26 in

(1) in

1 7/16 in

1 1/4 in

1 in

26 in

26 in

26 in 26 in

(1) in

7/16 in THRU

TYP. 8 PLACES

(2) FIELD DRILLED

(6) SHOP DRILLED

FIELD DRILL

FIELD DRILL

FIELD DRILL

FIELD DRILL

FIELD DRILL

FIELD DRILL

1 in

26 in 26 in

26 in

26 in

1 in

7/16 in THRU

TYP. 8 PLACES

(2) FIELD DRILLED

(6) SHOP DRILLED

1 7/16 in9/16 in THRU

1 3/16 in

7/16 in THRU

CENTER

BOLT

CENTER

BOLT

CENTER

BOLT

9/16 in

7/16 in THRU

TYP. 8 PLACES

(2) FIELD DRILLED

(6) SHOP DRILLED

12 in

12 7/8 in

9 in

12 in

10 5/8 in

6 1/8 in

12 in

12 in

9 1/4 in

10 3/8 in

15 in

(9/16) in

(13/16) in

PARTS LIST

DESCRIPTIONPART NUMBERQTYITEM

T5 LOWER REINFORCEMENT ANGLE1101861

T5 MIDDLE REINFORCEMENT ANGLE1101962

T5 UPPER REINFORCEMENT ANGLE1102063

1/2" DIA. X 2" LONG GRADE 5 GALVANIZED BOLT1101294

1/2" DIA. F436 GALVANIZED WASHER110031175

1/2" DIA. A563 GRADE DH HEAVY HEX GALVANIZED NUT110021176

3/8" DIA. X 1.00" LONG SAE GRADE 5 GALVANIZED BOLT110341207

3/8" DIA. F436 GALVANIZED WASHER110321208

3/8" DIA. GRADE B GALVANIZED HEX NUT110331209

AG

AH

AJ

AK

AL

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

IMPORTANT NOTICE

REMOVAL OF THE EXISTING DIAGONAL BOLTS TO ALLOW

ITS REPLACEMENT WITH PART NUMBER 11016 WHEN

INSTALLING THE BACK TO BACK ANGLES WILL LEAD TO

STRUCTURAL INSTABILITY. THE REMOVAL OF THE SINGLE

DIAGONAL BOLT WILL EFFECTIVELY REMOVE THE

ASSOCIATED DIAGONAL FROM THE STRUCTURE CREATING

THE INSTABILITY. ADDITIONAL TEMPORARY HORIZONTAL

BRACING OR ANOTHER SUPERVISED APPROACHED MUST

BE INCORPORATED INTO THE REPLACEMENT PROCEDURE

OUTLINED IN THE RIGGING PLAN IN ACCORDANCE WITH TIA-322.

FACE VIEWS

TYPICAL ALL

THREE FACES

230` AGL

250` AGL

MODIFICATIONS REQURIED TO BE APPLIED TO SECTION T5:

FROM 230' TO 250' AGL

CONVERT EXISTING SINGLE 1-3/4" X 1-3/4" X 3/16" ANGLE X-BRACING TO

1-3/4" X 1-3/4" X 3/16" BACK TO BACK ANGLE X-BRACING

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

EXISTING

DIAGONAL

32°

DETAIL AG

DETAIL AH

TYPICAL

DETAIL AJ

TYPICAL

DETAIL AK

TYPICAL

DETAIL AL

TYPICAL

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

4 5 6

EXISTING

DIAGONAL

REINFORCEMENT

ANGLE

EXISTING ANGLE

7 8 9

7 8 9

7 8 9

2 3/16 in TYP.

PART NUMBER 11020

T5 UPPER REINFORCEMENT ANGLE

MATERIAL: 1-3/4" X 1-3/4" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

PART NUMBER 11019

T5 MIDDLE REINFORCEMENT ANGLE

MATERIAL: 1-3/4" X 1-3/4" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

PART NUMBER 11018

T5 LOWER REINFORCEMENT ANGLE

MATERIAL: 1-3/4" X 1-3/4" X 3/16" A-36 STEEL ANGLE

(6) REQUIRED TOTAL

FINISH: HOT DIPPED GALVANIZED

DETAIL BE

BE

A A

B B

EET, LLC

Granger, IN USA

1-574-277-0670

PROPRIETARY

This drawing is the proprietary property of EET, LLC and may not be used, adapted, reproduced, copied, or disclosed without the prior written consent of EET, LLC.

PAGE

DRAWN BY: DATE:

APPROVED BY: DATE:

JRE

1/2/2018

JRE

6/13/2018

DRAWING NO.

B

OAKLAND COUNTY TOWER

MODIFICATIONS

SIZE:

Oakland County

Tower

Modification R5

REVISION:

SCALE:

N.T.S.

Owner: Prepared For:

Engineering by:

119 7/8 in

126 3/8 in

119 7/8 in

1 3/4 in

1 3/4 in

3/16 in

N.T.S

N.T.S

N.T.S

1 3/4 in

1 3/4 in

3/16 in

1 3/4 in

1 3/4 in

3/16 in

1 in

26 in

26 in

9 1/4 in

4 5/8 in

26 in

26 in

1 1/8 in

1 5/16 in

FIELD

DRILL

FIELD

DRILL

FIELD

DRILL

FIELD

DRILL

FIELD

DRILL

FIELD

DRILL

1 in

26 in 26 in

12 3/8 in

8 in

26 in 26 in

20 3/8 in

1 5/16 in

1 1/8 in

1 in

1 5/16 in

1 in

26 in 26 in

9 1/4 in

4 5/8 in

26 in 26 in

1 in

13 7/8 in

1 1/8 in

CENTER

BOLT

CENTER

BOLT

CENTER

BOLT

CENTER

BOLT

TYP.

1 5/16 in

ALL OTHER BOLTS

1 1/8 in

9/16 in

THRU

7/16 in

THRU TYP.

7/16 in THRU

TYP. 6 PLACES

(2) FIELD DRILLED

(4) SHOP DRILLED

7/16 in THRU

TYP. 7 PLACES

(2) FIELD DRILLED

(5) SHOP DRILLED

7/16 in THRU

TYP. 6 PLACES

(2) FIELD DRILLED

(4) SHOP DRILLED

9 in

3 3/8 in

File details come from the government source that posted it. Updated .