AD2066-2 _USDA_OCIO_ITS_Requirements.pdf
PDF 37 KB Posted
- Solicitation number
- NRCS-14-001
About this file
USDA/OCIO/ITS Requirement (USDA form AD-2066 SFO attachment 2)
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Cover_Letter_(modification_No._0001).docx | DOCX document | |
| NRCS-WV-14-001__Amendment_No._001_(GSA_Simplified_RLP_Form_R101A).docx | DOCX document | |
| GSA_FORM_1364A.pdf | ||
| GSA_Form_3518A_(Reps_ _Certs).pdf | ||
| USDA_DR3902-001_(IT_Wiring_Standards).pdf | ||
| Prelease_FPLS_Evaluation_(Form_12000 _Part_A_ _Part_B).docx | DOCX document | |
| Facility_Security_-_Level_I_.pdf | ||
| AD-2066_SFO_Space_Information.pdf | ||
| NRCS-WV-14-001_(GSA_Simplified_RLP_Form_R101A).docx | DOCX document | |
| GSA_Form_1364A-1.pdf | ||
| USDA_DR3901-001_(ITS_Space_Standards).pdf | ||
| GENERAL_CLAUSES_(GSA_FORM_3517B).pdf | ||
| Lease_No._57-3D47-14-001_(GSA_Form_L201A).docx | DOCX document | |
| Cover_Letter.docx | DOCX document |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INITIALS: Lessor: ______ & Government: _______ Page 1 of 6
AD-2066 SFO Attachment U.S. DEPARTMENT OF AGRICULTURE (11-26-08)
USDA/OCIO/ITS REQUIREMENTS
I. SPECIFICATIONS FOR THE ADP ROOM
A. Design. The ADP room shall be designed to accommodate only ADP and telephone equipment. The room shall be a minimum of 75 square feet and a maximum of 100 square feet. The configuration of the room shall allow a three-foot clearance around equipment.
B. Design Approval. Initial floor plans and final floor plans must be provided to the RPLO prior to beginning construction. The RPLO will forward the initial floor plan to the OCIO/ITS Group Manager for approval. The RPLO will forward the final floor plan to the ITS Realty Specialist for approval. The plans must include the locations of all phone jacks, data ports, and electrical outlets.
C. Walls. Walls of the ADP room shall extend from the structural floor slab to the structural ceiling slab with a noise isolation class (NIC) of no less than 40. This standard is mandatory for new construction and for existing facilities undergoing major renovations. A waiver may be obtained for existing facilities when no other renovations are required.
D. Flooring. The flooring shall be anti-static hard surface; no carpet.
E. Doors and Doorways. The number of entrances to the ADP room shall be kept to a minimum as required by local fire code. Every entrance into an ADP room shall be a lockable metal clad or lockable solid core door. Access to the room shall be by electronic card reader in offices where readers are installed for other doors. Where card readers have not been installed, the lock(s) shall be either keyed lock(s) or combination lock(s). ADP rooms shall not be keyed the same or have the same combination as other doors in the building. Exterior doors shall have either interior hinges or exterior hinges with non-removable pins.
F. Windows. There shall be NO windows in the ADP room or ADP room door.
G. Temperature and Humidity. The ambient room temperature shall be maintained between 68º to 75ºF (20º to 24ºC). The ambient relative humidity levels shall be maintained between 45% and 55%. The controls for both temperature and humidity must be located within the ADP room. Environmental sensors which display temperature and relative humidity conditions are required in the ADP room and shall be mounted out of any direct air flow. The ADP room environment must be controlled seven days a week, 24 hours a day, with no exceptions.
Points of contact for emergency situations shall be posted by the door of the ADP room.
H. Location. Where possible, the ADP room shall (a) be located within the interior of the building and away from public areas; (b) not be located above or below public areas in multi-story buildings; and not be located in close proximity to mailrooms or loading docks.
I. Plumbing. There shall not be water bearing pipes located above any portion of the ADP room.
INITIALS: Lessor: ______ & Government: _______ Page 2 of 6
AD-2066 SFO Attachment
I. SPECIFICATIONS FOR THE ADP ROOM (continued)
J. Fire Suppressant Systems. A sprinkler system will be installed when local building codes require it. A dry-pipe system is preferred. Sprinkler heads shall be placed so that they are not directly above any equipment. Each ADP room shall be equipped with a 5 to 6 pound FE-36 fire extinguisher. An annual inspection must be performed on the fire extinguisher.
K. Electrical Power. Where possible, the capability of shutting off power to an information system component that may be malfunctioning or threatened without endangering personnel by requiring them to approach the equipment shall be included in a new or refurbished ADP room.
L. Signage. Ensure that all signs identifying the ADP room are removed from public view.
Directories or building maps that identify the location of critical or sensitive asset locations shall not be displayed.
II. DEDICATED ELECTRICAL CIRCUITS AND OUTLETS FOR ADP EQUIPMENT
A. Circuits. Dedicated electrical circuits with isolated grounds are required. Duplex outlets shall be available for each dedicated electrical circuit. Dedicated circuits shall be 110 volt, 20-ampere standard three-prong circuits with true earth ground terminated into orange or other uniquely marked (“computer use only”) duplex outlets. Dedicated electrical circuits are also required for the telephone systems. The main electrical panel for the computer/voice (if computer/voice is available) equipment will be properly grounded to meet EIA/TIA and FIPS standards.
B. General Office Space Circuits. Provide dedicated electrical circuits with multiple outlets at designated locations throughout the service center with multiple outlets to accommodate the peripheral equipment (i.e. computer workstations, printers).
C. Electrical Requirements for Uninterruptible Power Supply (UPS) Circuit. Critical servers are required to be connected to the UPS.
1. Uninterruptible Power Supply (UPS). Dedicated Circuits are required for the Uninterruptible
Power Supply (UPS).
2. Number and Type of Circuits. Two 120 volt, 30 amp minimum circuits with true ground, terminated into a twisting-lock receptacle are required. Each dedicated circuit must have insulated, isolated earth ground (conduit ground is not acceptable).
3. Receptacle. The receptacle shall be a NEMA L5-30R twist-locking receptacle.
4. Location of the UPS receptacle. The UPS receptacle shall be located in the ADP room where the LWV cabinet is located. The receptacle shall be located no further than 4.5 feet from where the back of the USDA wiring cabinet will be.
INITIALS: Lessor: ______ & Government: _______ Page 3 of 6
III. TELEPHONE SYSTEM
A. Backboard. A 4 ft. x 8 ft. sheet of plywood shall be vertically mounted on the wall in the ADP
Room. Plywood thickness shall be nominal ¾”, as well as painted with fire retardant paint. A replacement material, that exceeds or meets the structural equivalent of plywood, that is also fire retardant, or treated to be, can be used as long as the thickness (11/16” through 1”) is able to support equipment to be mounted on the surface. The backboard shall be within 3 feet of an electrical outlet and the wiring cabinet. The backboard should be attached to the wall using correct mounting hardware and procedures. If the wall is sheet-rocked, the backboard shall be attached to the studs. If the wall is concrete, the backboard shall be attached using anchors.
The backboard shall be painted with fire retardant paint the same color as the interior walls of the building. This will be the extended demarcation point and for the installation of phone equipment.
B. DMARC. A telephone demarcation point (DMARC) shall be provided on a type 66S block on the backboard for all telephone lines prior to the move date. The telephone demarcation shall be inside the building. The telephone system will be moved to new locations and installed by USDA technicians during move-in.
IV. DATA CABLING/TELECOMMUNICATIONS
A. General Specifications. All cabling will meet local building codes. All premise data/telecommunications cabling will comply with TIA/EIA-568-B. All new installations will use Category 6 cabling, as specified in TIA/EIA-568-B.2-1, or higher. Renovations to buildings which currently comply with TIA/EIA-568-A and contain Category 5 cable and terminations may continue to use Category 5 wiring and terminations as specified in TIA/EIA-568-A. (Note:
Category 5 wiring is unsuitable for Ethernet speeds above 100 Mb/sec.)
B. Distribution Points. Facilities requiring multiple distribution points within the building or on multiple floors will comply with ANSI/TIA/EIA-569-B.
C. Cabling. When cable consists of multiple runs, the Lessor shall provide cable trays or J hooks to insure that the cable does not come into contact with suspended ceiling.
D. Copper Cable Specifications (New Installations). All cable equipment and materials must be manufactured by facilities that are International Organization for Standardization (ISO) 9001 registered and certified as follows:
1. Shall be CAT6 rating in accordance with ANSI/TIA/EIA 568B.
2. Shall be four-pair, UTP, 100-Ohm, 24 American Wire Gage (AWG).
3. The selected cable must have contiguous, two-foot segment-length markers printed on the cable jacket. The markings must also show cable manufacturer, cable model number or name, cable part number, CAT6 designation, a UL or ETL verification designation, a CMP type, and a “tested to 350 Mhz” or above designation.
4. Shall be tested and certified by the installer to comply with the previous requirements.
5. Provide, place, terminate and test Cat-6 certified 100-ohm Balanced Twisted Pair cables according to applicable standards.
6. Data cable and voice cables shall be terminated with Cat-6 compliant terminations (patch panels, wall outlets, etc.).
7. All Balanced Twisted Pair cables shall be terminated using the T568A pin/pair assignments as specified in TIA/EIA-568-B and per FTR 1090-19
INITIALS: Lessor: ______ & Government: _______ Page 4 of 6
IV. DATA CABLING/TELECOMMUNICATIONS (continued)
E. Data Fiber Cable Specifications (New Installations).
1. All fiber cable shall be 6-strand, multimode, tight buffered, 50 x 125 µm optical fiber, rated
OFCP, and must be clearly marked as such on the cable sheathing.
2. All fiber link cable runs, shall be run within orange, plenum rated inter-duct, and appropriately sized according to the number of fiber runs to be contained.
3. Both the fiber cable sheathing and the protective inter-duct shall be colored orange to denote multimode fiber.
4. Fiber optic cable shall be used for all links in excess of 90 meters and where appropriate.
There shall be no 90º bends in any fiber cables with a radius of less than three (3) inches.
5. All fiber cable links less than 500 meters shall be 6-strands, multimode optical fiber cable.
6. All OFCP or OFCR rated fiber cable shall be properly grounded at both ends and may not be installed in the same cable tray or conduit as power cables.
7. All ANSI/TIA/EIA – 568B requirements for fiber cable installation, testing, and termination will be observed.
8. All strands of each fiber cable shall be terminated at each end of the cable, with either ST or SC connectors, as appropriate to the related equipment interface connector, and will be conveyed to the selected cable contractor upon request.
SC Connector ST Connector
9. Supply several sets of fiber patch cords that should not only serve immediate switch connection concerns, but allow for possible switch update connections in the future. The unused fiber patch cables will be kept in reserve at this site, in the event that such switch updates do occur.
INITIALS: Lessor: ______ & Government: _______ Page 5 of 6
IV. DATA CABLING/TELECOMMUNICATIONS (continued)
F. Wall Input/Output Face Plates for Work Area I/O Connections. Work areas shall have a quad or hex outlet plate connector with four or six RJ-45 connectors (see diagram). Extra outlet plate connectors will also be required in some common areas. All drops shall be identified and numbered on the office floor plan prior to installation. Each of the four or six connectors shall be cabled with 4-pair UTP cable. The data cables shall be category 6 as listed in the cable specification block. These cables shall be terminated with RJ-45 connectors at the device end. The other end shall be punched down on an RJ-45/110-type patch panel in the LAN/WAN/VOICE wiring cabinet. Each quad plate shall be labeled with the work station number (1, 2 etc.) and the A, B, C etc. format. Each connection shall be identified as 1A, 1B, 2A, 2B, etc. on the corresponding patch panel location.
Quad Plate Hex Plate Quad Plate – Ports A, B, C – Data Hex Plate – Ports A, B, C, D, E - Data Port D- Phone Port F – Phone
V. LAN/WAN/VOICE CABINET
The government will provide the wiring cabinet. A wire service loop shall be provided during wiring to allow the cabinet to freely move at least 6 feet in any direction. The RJ-45/110 type patch panel shall be mounted in the cabinet in the place designated by the Government. The contractor shall supply the appropriately-sized patch panel based upon the number of quad and/or hex outlet plates.
INITIALS: Lessor: ______ & Government: _______ Page 6 of 6
VI. JOINT UNDERSTANDING BETWEEN THE GOVERNMENT & LESSOR REGARDING
STANDARD WIRING STANDARDS & SECURE ADP ROOM
The Government reserves the right to install its own voice and data cabling.
VII.COPIES OF RELATED DOCUMENTS
A. Copies of Federal Telecommunications Recommendations. Copies of FTRs are available from:
National Communications System, Technology and Standards Division (N6) 701 South Court House Road
Arlington, Virginia 22204-2198 Telephone: (703) 607-6204
B. Copies of the specifications and related documents. Copies of the specifications and related documents can be obtained from:
National Resource for Global Standards www.nssn.org
OR
Global Engineering Documents 15 Inverness Way East Englewood, Colorado 80112 Telephone: (800) 854-7179 or
(303) 397-7956 www.global.ihs.com
File details come from the government source that posted it. Updated .