NJ Backflow Inventory Updated.docx

DOCX document 15 KB Posted

Attached to
H345--F26 - NJHCS Backflow Preventers Testing and Inspection Services B+4OPT
Solicitation number
36C24226Q0312
Issued by

About this file

This is an inventory document listing backflow preventers at two VA Medical Center locations: East Orange and Lyons, New Jersey. The inventory details specific devices used across multiple buildings and facilities at each campus, identifying the manufacturer, size, model number, and serial number for each unit. At East Orange, the document lists backflow preventers located in the C-level and B-level buildings, with Ames and Watts manufacturers predominating, in sizes ranging from 2 inches to 8 inches, designated for either sprinkler or domestic water service. The Lyons campus inventory includes devices at the Chiller Plant, Water Main, and Wastewater Plant, with multiple Watts and Wilkins units ranging from 2 inches to 8 inches, and notes on specific locations and conditions such as missing nameplates on some units.

This inventory document directly supports the federal solicitation H345--F26 issued by the VA New Jersey Healthcare System (Veterans Integrated Service Network 2) seeking annual and quarterly testing and inspection services for backflow preventers at the East Orange and Lyons VAMCs. The inventory provides potential contractors with the specific equipment baseline they will be responsible for testing and inspecting under the contract, including approximately 30+ devices at East Orange and 15+ devices at Lyons across fire sprinkler systems, domestic water connections, and wastewater treatment plant applications. The documentation serves as essential reference material for contractors preparing proposals and estimating the scope of testing and inspection services required.

View the file

Other files

File Type Posted
36C24226Q0312 0001.docx DOCX document
36C24226Q0312_1.docx DOCX document
QASP.pdf PDF
PAST PERFORMANCE QUESTIONNAIRE- 36C24226Q0312.pdf PDF
Wage Determinations 2015-4211.pdf PDF
S04 - Site Visit - NJ Backflow Preventers.docx DOCX document
Wage Determinations 2015-4209.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

East Orange Inventory

Building Manufacturer Size Model# Serial# Sprinkler/Domestic 1 C-level Ames 8” 2000SS 69145-0911 S 1 B-level Watts 8” NSF-61C 16011 D 2 Watts 4” No. 709DCDA 143862 S 2 Watts 2” LF909 008940 D 15 Watts 4” No. 709DCDA 143864 S 15 Watts 4” LF909 168866 D 17 Watts 4” No. 709DCDA 143865 S 16 Watts 4” No. 709DCDA S 18 Watts 4” No. 709DCDA 143861 S 8 Watts 6” LF909 16258 D 7 Watts 4” LF909 17576 D 6 Watts 4” No. 709DCDA 143866 S 5 Watts 4” No. 709DCDA 143863 S 5 Watts 2.5” LF909 001378 D

Lyons Inventory Domestic Building Manufacturer Size Model# Serial# Comments Chiller Plant Watts 4” LF909 67853 135 Watts 6” 957 P1-1065 7 Watts 4” LF909 17591 53 Watts 4” LF909 22511 57 Watts 4” LF909 17611 143 Top Wilkins 4” 975 B14569 143 Bottom Wilkins 4” 975 B14596 Water Main Watts 6” LF909 18258 Water Main Watts 8” LF909-M1 16599 14 Apollo 2” RPLF4A 11481A 14 Watts 3” LF909 001841 RPZ Backflow preventer on tag?

14 Watts 3” Unknown Unknown No nameplate on unit

Lyons Wastewater Plant:

Quarterly Testing Lyons Campus Wastewater Plant:

Building Manufacturer Size Model# Serial# Comments 141 Watts 2” LF009M2QT 017447 Sewer plant downstairs front unit 141 Watts 2” 009M2QT 334820 Sewer plant downstairs back unit