ItemDatapoint NameDescriptor:Drawing KeyDevicePart NumberRange
1ECHWSChwFlo1Chilled Water FlowFV-1SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO550 - 5000 GPM
2ECHWSChwFlo2Chilled Water FlowFV-2SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO551 - 5000 GPM
3ECHWSChwFlo3Chilled Water FlowFV-3SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO552 - 5000 GPM
4ECHWSChwRetPresEB Chilled Water Return PressurePGV-2Veris: Gauge pressure, transducer, 0-100psi =4-20mA,PH-X-07-S3 - 5000 GPM
5ECHWSChwSupTempEB Chilled Water Supply TempTNW-1Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS4 - 5000 GPM
6WCHWSAC23SupPressAC 23 Supply PressurePGU-2Veris: Gauge pressure, transducer, 0-50psi =4-20mA,PH-X-07-S5 - 5000 GPM
7WCHWSBldgHeadPresWest Bldg Hd PressurePGU-1Veris: Gauge pressure, transducer, 0-250psi =4-20mA,24VDCPH-X-08-S6 - 5000 GPM
8WCHWSChwHxRetTempChilled Water Return TempTNW-5Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS7 - 5000 GPM
9WCHWSChwHxSupTempChilled Water Supply TempTNW-4Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS8 - 5000 GPM
10WCHWSCwFloCondenser Water FlowFV-1SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO559 - 5000 GPM
11WCHWSCwSupTempCondenser Water Supply TempTNW-1Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS10 - 5000 GPM
12WCHWSPrimChwFloHX Primary Chilled Water FlowFVN-1SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO5511 - 5000 GPM
13WCHWSPrimChwHxFloHX Primary Chilled Water FlowFV-2ABB Hart ????12 - 5000 GPM
14WCHWSSecChwFlo1East Bldg Sec Chilled Water FlowFV-3SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO5513 - 5000 GPM
15WCHWSSecChwFlo2West Bldg Sec Chilled Water FlowFV-5SeaMetrics: Electromagnetic Inserstion Flow Sensor with SeaMetrics: Analog Transmitter, 4-20mA, 24VDCEX215-B with AO5514 - 5000 GPM
16WCHWSSecChwSupTmp1EB Sec Chilled Water Supply TempTNW-6Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS15 - 5000 GPM
17WCHWSSecChwSupTmp2WB Sec Chilled Water Supply TempTNW-7Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS16 - 5000 GPM
18WCHWSSecSucHdPresSecondary Suction Hd PresPGY-1Veris: Gauge pressure, transducer, 0-250psi =4-20mA,24VDCPH-X-08-S17 - 5000 GPM
19WCHWSUWHxRetTempHX Utility Water Return TempTNW-3Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS18 - 5000 GPM
20WCHWSUWHxSupTempHX Utility Water Supply TempTNW-2Kele: immersion, PT1000 RTD, 0-100F, 4-20mA withT91U-EMC-3-WS19 - 5000 GPM
21WCHWSUWPmpDisPresUtility Pump Discharge PressurePGY-1Veris: Gauge pressure, transducer, 0-250psi =4-20mA,24VDCPH-X-08-S20 - 5000 GPM
22EBChwSupPressureEB 8th Floor Chw Pressure???Veris: Gauge pressure, transducer, 0-100psi =4-20mA,24VDCPH-X-07-S21 - 5000 GPM
23ECHWSPod3PresEB Pod3 Level 7 Pressure???Veris: Gauge pressure, transducer, 0-100psi =4-20mA,24VDCPH-X-07-S22 - 5000 GPM
24WCHWSUWSupplyTempUtility Water Supply TemperatureTNW-1ABB Hart Programmable Transmitter with NBS RTD -20 to 204 4-20mAABB TH202 with NBS 10U-86-10023 - 5000 GPM
25WCHWSUWReturnTempUtility Water Return TemperatureTNW-2ABB Hart Programmable Transmitter with NBS RTD -20 to 204 4-20mAABB TH202 with NBS 10U-86-10124 - 5000 GPM
26WCHWSHxChwSupplyTempChiled Water Supply TemperatureTNW-4ABB Hart Programmable Transmitter with NBS RTD -20 to 204 4-20mAABB TH202 with NBS 10U-86-10225 - 5000 GPM