This document provides test results for privacy curtains submitted in response to solicitation F3G4BA3188AW01 from the Department of the Air Force Air Combat Command. A sample of 52% PCR polyester and 48% FR polyester privacy curtain identified as F- 0256027-01100002 S0#15422634-10 and weighing 6.5 ounces per square yard was tested according to NFPA 701-10 Test 1. The material passed the requirements, with an average flaming dripping time below 2.0 seconds, average weight loss of specimens below 40% and no individual specimen deviating more than 3 standard deviations from the mean. The solicitation was for 99 MDG Privacy Curtains.
View the file
Other versions and copies of NFPA 701
| File | Revision | Posted | Attached to |
|---|---|---|---|
| NFPA_701_Rev_15,_Fire_Tests_for_Flame_Propagation_of_Textiles_and_Films.pdf | Rev. 15 | USS SAMPSON 8C1 DSRA |
Who attaches NFPA 701
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NFPA 701-10 TEST 1 EXAMPLE
Test Method:
The medical privacy curtains quoted, in response to the solicitation F3G4BA3188AW01 (99 MDG Privacy Curtains), was tested in accordance with the National Fire Protection Association (NFPA) 701- 10, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films, 2019 Edition, Test Method 1.
Material Tested:
The client submitted a sample of 52% PCR polyester, 48% FR polyester privacy curtain identified as F- 0256027-01100002 S0#15422634-10. The fabric had a total weight of 6.5 ounces per square yard.
Test Data:
Statistical Values:
Standard Deviation = 4.99
Mean + 3 Standard Deviations = 26.7
Performance Criteria: A material passes the test if:
The average Flaming Dripping time does not exceed 2.0 seconds.
The average weight loss of the 10 specimens shall be 40 percent or less; and No individual specimen’s mass loss shall deviate more than 3 standard deviations from the mean.
After flame time is not specified; it is shown for information purpose only.
Test Result:
The material tested MEETS the requirement of NAPA 701-10, Test 1.