Boiler Tube Replacement, Repair, Patching and Caulking Services Solicitation

This solicitation document is issued by the Newark Board of Education (NBOE) Department of Purchasing for boiler tube replacement, repair, patching, and caulking services across multiple school facilities. The contractor must furnish all labor, equipment, materials, and parts to perform boiler tube replacement, repair, patching, and caulking services, including welding on boilers at various NBOE locations. All welding work must conform to New Jersey Department of Labor and Workforce Development prevailing wage rates for boilermakers, and welders must hold NJ R-Stamp certified welding licenses. Upon project completion, contractors must provide state-certified boiler-welding inspection certificates. The solicitation was issued on October 29, 2026, with a virtual pre-submission meeting scheduled for November 4, 2026, at 10:00 a.m. EST. All written questions must be submitted via the electronic bidding platform prior to 2:00 p.m. EST on November 4, 2026, with answers provided at least seven days before bid acceptance. Bids are due electronically via https://npssourcing.com/ prior to 12:00 p.m. EST on November 19, 2026, with public opening immediately following the deadline. The contract is for two years from the date of award with an option to renew for one additional two-year period, with an anticipated initial term of January 1, 2027, through December 31, 2028. Attachment A provides a comprehensive boiler inventory across approximately 75 NBOE school locations and facilities, detailing equipment makes, models, serial numbers, burner types, fuel specifications, and permit information.

Pricing shall be entered electronically and remain firm for the contract period, with no separate billing allowed for travel time, mileage, or tolls. All prices must include labor, overhead, administrative costs, and profit. The solicitation is unrestricted with no identified set-aside. Award will be made to the lowest responsible and responsive bidder. Bidders must be pre-qualified with the New Jersey Department of Property Management and Construction (DPMC) in HVAC (C039) or Boilers—New/Repair (C033) classifications and demonstrate a minimum of five years' experience providing similar services. Contractors must maintain 24/7 emergency telephone and email availability and comply with all prevailing wage requirements, including submission of certified weekly payrolls within ten days of wage payment to the NBOE Office of Facilities Management at 190 Muhammad Ali Avenue, Newark, NJ 07108. Bid bond and performance bond are required. Insurance requirements include Comprehensive General Liability with minimum $1,000,000 Combined Single Limit, Workers' Compensation as required by New Jersey State Law, Commercial Automobile Liability with minimum $1,000,000 Combined Single Limit, and Installation Floater Insurance. The NBOE must be added as an additional insured on all policies. Liquidated damages of $250.00 per day per affected location apply for failure to make deliveries or provide services as specified. The District reserves the right to terminate the contract at any time for convenience with ten days' written notice and may extend the ordering period for an additional 90 days beyond expiration with no price increase.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attention Bidders Electronic Bidding Tutorial Videos Are Available Via https://www.nps.k12.nj.us/departments/purchasing/view-current-bids/

All bids will be received electronically via our electronic bidding platform https://npssourcing.com/ . Email Ledah Arbubaker for user credentials via larbubaker@nps.k12.nj.us

Bidders are encouraged to attend the virtual pre-submission meeting on Wednesday, November

4, 2026, 10:00 a.m. EST to review completion of the required documents and the electronic submission process. Virtual meeting credentials are below.

Webex Link: https://nboe.webex.com/

Meeting Number: 2862 665 3939

Password: iRvQnCHm842

Dial In: (646) 992-2010

All questions shall be submitted in writing via the bidding platform prior to 2:00 p.m. EST

Wednesday, November 4, 2026. The specific section and page number to which each question refers is to be indicated. Answers will be provided at least seven days prior to the acceptance of bids.

Bidders are required to submit pricing via the Pricing - Enter Bids section.

Bidders are required to upload their signed and complete bid with all required documents and signatures in the Questionnaire - Answers Questions section. The complete bid must be submitted prior to 12:00 p.m. EST Thursday, November 19, 2026 via https://npssourcing.com/

Bids will be publicly opened and announced directly after the submission deadline. Virtual meeting credentials are below.

Webex Link: https://nboe.webex.com/

Meeting Number: 2863 775 0469

Password: iUjEKrBY733

Dial In: (646) 992-2010

This Bid will be opened electronically at 12:00 P.M. on

THURSDAY, NOVEMBER 19, 2026 SOLICITATION 10272

DESCRIPTION

BOILER TUBE REPLACEMENT, REPAIR, PATCHING AND CAULKING SERVICES

TWO (2) YEAR CONTRACT WITH AN OPTION TO RENEW FOR ONE (1) ADDITIONAL TWO (2) YEAR PERIOD

The solicitation is

UNRESTRICTED SET-ASIDE

This is a ____% set-aside for

SMALL MINORITY WOMEN OWNED

BUSINESS BUSINESS BUSINESS

FOR BIDDING PLATFORM CREDENTIALS EMAIL: LEDAH ARBUBAKER LARBUBAKER@NPS.K12.NJ.US

If you do not wish to respond, please identify why within the electronic bidding platform.

COMMENTS:

BIDDERS ARE REMINDED THAT THIS IS AN ELECTRONIC BID. THE NEWARK BOARD OF

EDUCATION UTILIZES EC SOURCING GROUP’S FLEX RFP ELECTRONIC BIDDING SYSTEM.

BID SURETY/BOND AND PERFORMANCE BOND REQUIRED, SEE PARAGRAPHS F1 AND F2.

ALL QUESTIONS MUST BE SUBMITTED IN WRITING VIA THE ELECTRONIC BIDDING PLATFORM

HTTPS://NPSSOURCING.COM/ PRIOR TO 2:00 P.M. WEDNESDAY, NOVEMBER 4, 2026. ANSWERS WILL

BE PROVIDED AT LEAST SEVEN DAYS PRIOR TO THE ACCEPTANCE OF BIDS.

PRICING MUST BE ENTERED ELECTRONICALLY VIA HTTPS://WWW.NPSSOURCING.COM/

ALL BID SUBMISSIONS MUST BE SUBMITTED PRIOR TO 12:00 P.M. EST, THURSDAY, NOVEMBER 19, 2026 VIA HTTPS://WWW.NPSSOURCING.COM/

Newark Board of Education

Department of Purchasing

765 Broad Street Newark, New Jersey 07102-3091

SOLICITATION, BID OFFER AND AWARD

1. SOLICITATION NO. 10285 2. DATE ISSUED: Thursday, October 29, 2026

3. CONTRACT NUMBER: 4. CONTRACT PERIOD:

FROM ________________________________

TO: ___________________________________

5. DESCRIPTION: BOILER TUBE REPLACEMENT, REPAIR, PATCHING AND CAULKING SERVICES - TWO (2) YEAR CONTRACT WITH AN OPTION TO

RENEW FOR ONE (1) ADDITIONAL TWO (2) YEAR PERIOD

6. BIDS SHALL BE SUBMITTED ELECTRONICALLY VIA THE BIDDING PLATFORM. YOUR BID MUST INCLUDE ALL REQUIRED DOCUMENTS AND A SIGNATURE IN BOX NUMBER 17. ALL BIDS ARE DUE PRIOR TO 12:00 P.M. THURSDAY, NOVEMBER 19, 2026 MODIFICATION AND WITHDRAWALS ARE

SUBJECT TO ALL TERMS AND CONDITIONS IN THIS SOLICITATION.

7. SUBMIT ALL QUESTIONS VIA THE BIDDING PLATFORM

8. TABLE OF CONTENTS

Solicitation, Bid Offer, and Award Certifications Section C - General Specifications Subcontractor Disclosure Statement Section D - Special Conditions Prevailing Wage Certification Attachment A - Boiler Inventory Lowest Bidder Prevailing Wage Certification Signature of the Bidder Contractor’s Registration Certificate Attachment B – Bidder’s Questionnaire Total Amount of Uncompleted Contracts Political Contribution Disclosure Certification of Non-Debarment for Federal Government Contracts

Statement of Ownership Disclosure Initial Project Workforce Report Construction Certification of Non-Involvement in Prohibited Activities in Russia or

Belarus AHER Contractor Notification

Disclosure of Investment Activities in Iran Instructions, Conditions and Notices to Offerors – Section E Non-Collusion Affidavit Mandatory Equal Employment Opportunity Language Newark Board of Education Vendor Setup Form Bid Checklist Equipment Certification Sample Prevailing Wage Determination

BID AND OFFER (Must be completed by the bidder)

9. BIDDERS FEDERAL ID NO.

9A. BIDDER’S EMAIL

10. BIDDERS TELEPHONE NO.

11. DISCOUNT FOR PROMPT PAYMENT

(SEE SECTION E: PAR. 14)

12. N/A

13. N/A

14. The undersigned agrees, if this offer is accepted within 90 calendar days (90 calendar days unless a different period is inserted by the offerer) from the date of receipt of offer specified above, to furnish any or all items upon which prices are offered at the prices set opposite each item, delivered at the designated point(s) within the time specified in the schedule.

15. Signature by the bidder attests that she/he has read, understands, and agrees to all terms, conditions, and specifications set forth in the solicitation unless otherwise stated in writing and submitted in writing with his/her bid. Furthermore, signature by the bidder signifies that this is a contract immediately upon notice of award of contract by the School District for any or all of the items bid, and for the length of time indicated in the bid. Failure to accept a contract within the time period indicated by his/her proposal or failure to hold prices or to meet any other terms and conditions as defined in his/her bid during the term of the contract, shall constitute a breach and may result in suspension or debarment from further bidding to The Newark Board of Education. A defaulting contractor may also be liable, at the option of the School District, for the difference between his/her bid price and the price of an alternate source of supply.

16. DATE

17. SIGNATURE OF THE BIDDER (Must be signed)

(L.S.) x____________________________________

(Printed Name of Person Authorized to Sign Offer)

(Title)

18. COMPANY NAME

(Address: NO P.O. Box)

(City) (State) (Zip)

AWARD (To be completed by The Newark Board of Education)

19. Contract Value: _________________________________________

The District’s liability is limited to the dollar amount stated on the District’s purchase order/s issued by the Purchasing Agent.

20. Board Approval Date: ____________________________________________

Purchasing Department 765 Broad Street

Newark, New Jersey 07102-3091

INSTRUCTIONS TO BIDDERS FOR COMPLETING THIS PROPOSAL

1. Read the entire bid proposal, including all terms, conditions and specifications.

2. All bid prices shall be entered via https://npssourcing.com/ .

3. This bid proposal is to be signed in Box #17

4. Bid prices shall include delivery of all items. F.O.B. DESTINATION, FREIGHT

PREPAID or as otherwise provided.

5. Ensure all items listed in the enclosed checklist are complete and submitted.

FOR NEWARK BOARD OF EDUCATION USE ONLY

21. APPROVED AS TO COMPLIANCE WITH BIDDING REQUIREMENTS

Director of Support Services

Date:________________________________

22. REVIEWED AS TO LEGAL FORM

Newark Board of Education Counsel

23. SIGNATURE OF THE BOARD’S CONTRACTING AGENT: (Must be signed)

School Business Administrator

24. SIGNATURE OF THE BOARD’S CONTRACTING AGENT:

Board Chairperson (signature required if contract is valued over $53,000.)

25. Please provide the following employment statistical data.

Vendors that are classified as Small, Minority, or Woman-Owned business, please provide copies of your New Jersey Set-

A-Side certification.

This firm is a: Commercial_____ Non-Profit_____ Government Agency_____

This firm is a: Large_____ Small_____ (100 employees or less)

This firm is a: Woman owned business_____(51% or more of ownership is held by women)

This firm is a: Minority owned business_____ (51% or more of ownership is held by minorities)

If minority, please check (√). Minority is defined as:

African American_____ Hispanic American_____

(Black racial groups in Africa) (Spanish or Portuguese culture with origins in Mexico, South or Central America or Caribbean Islands)

American Indian or Alaskan Native _____ Asian American_____

(Origins North America) (Origins of the original people of the Far

East, Southeast Asia, the Indian Subcontinent, Hawaii or the

Pacific Islands)

Please check (√) the appropriate box:

◻ Individual/Sole Proprietor ◻ Corporation ◻ Partnership ◻ Other

PERCENTAGE OF PERMANENT MINORITY/NON-MINORITY EMPLOYEE BREAKDOWN

MALES

FEMALES

TOTAL #

OF

EMPLOYEES

BLACK

HISPANIC

AMER.

IND.

ASIAN

NON-

MIN.

BLACK

HISPANIC

AMER.

IND.

ASIAN

NON-

MIN.

READ, REVIEW AND COMPLY

It shall be the bidder’s responsibility to read the entire document, review all enclosures and attachments, and comply with all requirements specified herein. Each bidder shall be deemed to have read and to be fully familiar with the bid/contract requirements and documents. Failure on the part of bidder to familiarize themselves with the request for bid package shall not release them of their obligation to fulfill the services as outlined.

SECTION C – GENERAL SPECIFICATIONS

C1 SCOPE OF WORK

C1.1 Contractor shall furnish all labor, equipment, materials, and parts to perform boiler tube replacement, repair, patching and caulking services, including welding on all boilers for various locations within the Newark Board of

Education (NBOE, District).

C1.2 All welding shall conform to the rules and regulations as established by the New Jersey Department of Labor and

Workforce Development prevailing wage rates governing Boilermaker.

C1.3 The awarded Contractor performing public works for the NBOE shall be required to pay the established wage and fringe benefit rates as guided by New Jersey Department of Labor and Workforce Development Prevailing Wage rate for the craft of Boilermaker. Welders shall have a NJ R-Stamp certified welding license. Upon completion of each welding project, the Contractor shall provide the Director of Project Control and/or appointed designee with a State certified boiler-welding inspection certificate specific to that project.

C1.4 Equipment to be repaired must be tagged or labeled at the time of repair. This tag shall display the copyright-protected repair symbol of the National Board Inspection Code (NBIC) and show the name of the Contractor, date, type of repair performed and the name and signature of the mechanic who performed the work.

C1.5 Whenever possible, subsequent repairs at particular sites shall be performed by the same service mechanic originally assigned.

C1.6 Any defective or malfunctioning equipment shall be repaired during the service call and/or reported to the

Director of Project Control and/or designee as soon as it is discovered. If further extensive repairs to equipment are needed, the Contractor may be required to submit a written detailed time/materials estimate for repairs.

C1.7 The awarded Contractor must receive written, signed approval from the Director of Project Control and/or designee before proceeding with any work. All completed jobs shall be inspected and approved by the Director of

Project Control and/or designee prior to payment.

C1.8 Pre-approval from the Director of Project Control is required for repair parts in excess of $1,000.00.

C1.9 Upon request, the successful Contractor may be required to provide consulting services for existing equipment and submit a detailed analysis for repairs or replacement. This will be paid for at the normal service hourly rates.

C1.10 The Newark Board of Education reserves the right to accept the Contractor’s estimate for repairs or to have the work performed by Newark Board of Education personnel or others.

C1.11 If equipment must be shut down for service or repairs, the Contractor is required to coordinate the schedule with the Director of Project Control and/or designee.

C1.12 The awarded Contractor is required to sign in/out of each Newark Board of Education location.

C1.13 The school directory is available via https://www.nps.k12.nj.us/schools/ .

C1.14 The Contractor covenants and agrees at all times during the effective term of the contract to observe all applicable

City, County, State and Federal Laws, ordinances, rules, and regulations. The Contractor further agrees to indemnify and hold harmless the District and its officers, agents, and employees from all claims, damages, losses, and expense arising out of or resulting from the performance of the Contractor, his officers, agents or employees.

C2 CODES

C2.1 All projects must conform to the Uniform Construction Code (UCC), applicable building, electrical, mechanical, plumbing and safety codes.

C2.2 Permits are not required for ordinary repairs, as defined by the UCC. When permits are required, the Contractor shall be responsible for preparing properly signed/sealed drawings, sketches, and applying for permits. The cost shall be included in the project cost.

C3 GUARANTEE

C3.1 All major assemblies’ components and/or parts replaced by the Contractor shall be guaranteed against any material defect and poor workmanship for a period of one (1) year from date of installation, unless otherwise specified.

C3.2 The Contractor shall provide a written guarantee for all major assembly/components and/or parts furnished to the

Newark Board of Education.

C4 BOILER TUBE REPAIRS, WELDING & INSULATION

C4.1 All tubes shall be of new seamless steel quality boiler tubes, manufactured in the United States in accordance with The American Society of Mechanical Engineers (ASME) Code, following standard gauge sizes:

Standard size 1.5" fire tube, #12 gauge

Standard size 2" fire tube, #12 gauge

Standard size 2 1/2" fire tube, #12 gauge

Standard size 3" fire tube, #12 gauge

Standard size 3 1/2" fire tube, #11 gauge

Standard size 4" fire tube, #10 gauge

Standard size 2”-24” water tube

The tube diameters provided are approximate. All tubes are to extend 3/16" approximately, on each end. Tubes located in the FIRST PASS in the boiler MUST BE PROPERLY ROLLED AND BEADED

FLUSH TO THE TUBE SHEET on each end. All other tubes can be rolled and flared; or rolled and beaded, on each end as needed to seal the tube. The Contractor shall use firebox steel flange plate material on all boiler shell patch repairs. All welding on steel boiler shells, patch repairs, seams and seal welding shall be arc electric homogeneous welding by certified welders.

All bidders shall be NJ R-Stamp (repair) certified with a welding license. Bidders shall include a copy of their R-

Stamp certified welding license with their bid submission.

C5 TUBE REPLACEMENT

C5.1 This contract requires the replacement of boiler tubes at multiple schools within the Newark Board of Education.

All replacement sizes, gauges, and fabrications shall be as prescribed in these specifications and in accordance with American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code (BPVC).

C6 PROTECTION OF EQUIPMENT

C6.1 The Contractor shall remove grates wherever necessary to proceed with the project, and replace same when finished. All motors and openings into boiler settings, especially those equipped with forced draft systems, are to be carefully covered to prevent dirt/debris from getting into the bearings or being otherwise damaged. The Contractor will be held responsible for any damage to grates, motors, and/or any other equipment.

C7 REMOVAL OF OLD MATERIALS

C7.1 The awarded Contractor shall remove all old materials and debris created by his work as soon as the project is completed, leaving the boiler room in a broom clean condition.

C8 PROJECT RESPONSE TIME

C8.1 The awarded Contractor shall provide and maintain a twenty-four (24) hour, seven (7) day per week emergency telephone number and email address.

C9 PROJECT SERVICES - DEFINED

C9.1 NORMAL PROJECT SERVICE - is defined a service which is required within a five (5) working day period after request by the Newark Board of Education and will be conducted during normal working hours (within 7:00 a.m. - 5:00 p.m.) Monday through Friday, and school holidays excepted, unless otherwise specified by the

NBOE. Any overtime must be approved by the Director of Project Control and/or appointed designee before work is initiated.

a. Weekend Hours: only if authorized by the District in advance

b. Early Morning Hours: must be coordinated within mutually agreed upon time parameters by the Director of

Project Control and/or appointed designee and the School Principal for the following schools:

● John F. Kennedy School

● New Jersey Regional Day School

C9.2 Contractor work operations affecting school educational programs during the regular school days shall be coordinated and approved in advance by the Director of Project Control and/or appointed designee and the School

Principal.

The following holidays are recognized by the Newark Board of Education:

New Year’s Day Independence Day

Martin Luther King Jr. Day Labor Day

Presidents Day Indigenous People’s Day

Eid-al-Fitr Veteran’s Day

Good Friday Puerto Rico Heritage Day

Memorial Day Thanksgiving Day

Juneteenth Christmas Day

C9.3 NORMAL PROJECT SERVICE - CONTRACTOR SCHEDULED - is defined as a service to be accomplished by the Contractor at his discretion within a reasonable time frame. The intended, but firm date of this service must be conveyed to the Newark Board of Education within five (5) working days of the original request. This service will be conducted during normal working hours (within 7:00 a.m. - 5:00 p.m.) Monday through Friday, and school holidays excepted, unless otherwise specified by the NBOE. Any overtime hours must be approved by the Director of Project Control and/or appointed designee before work is initiated.

C9.4 OVERTIME SERVICE - includes service rendered outside the hours of 7:00 a.m. – 5:00 p.m. on weekday and/or service rendered on Saturdays, Sundays, and Legal Holidays.

C10 REPORTING REQUIREMENTS

C10.1 The Contractor shall maintain a complete written record of all emergency call-back, replacement, and repair work performed. This information shall be consolidated by the Contractor and dispatched to the Director of Project

Control and/or designee monthly. This monthly report shall indicate the date work was performed, type of work performed (callback, replacement or repair) must contain a brief description, man hours expended, and material used to complete the task. Failure to submit this report will be grounds to reject payment for this period.

C10.2 Routine maintenance visits require prior authorization. Payment will not be made for unauthorized service visits.

C10.3 The Contractor is required to obtain the signature of the school’s principal, head custodian or the Office of Project

Control designee upon completion of work.

SECTION D — SPECIAL CONDITIONS

D1 INTENT

D1.1 The intent of this solicitation is to award a contract for Boiler Tube Replacement, Repair, Patching, and Caulking services for the Newark Board of Education as specified within the terms and conditions of this request for bid.

The Contractor shall use qualified, trained, and experience personnel that is supervised by the Contractor.

D1.2 The conditions and requirements are intended to be open and non-restrictive and to serve as average standards to obtain adequate vendor participation, uniformity in the submission of bids, and selection of the most responsible vendors.

D1.3 The Newark Board of Education reserves the right to reject any and all bids and waive any informality in any proposal in accordance with applicable law. Award of contract is subject to the availability of funds.

D2 QUESTIONNAIRE/QUALIFICATIONS

D2.1 Contractor is required to complete the enclosed questionnaire. Failure to complete may deem your bid submission nonresponsive.

D2.2 Qualifications: Bidders shall be of known reputation and shall have sufficient qualified personnel and equipment to adequately perform boiler tube replacement, repair, patching, and caulking services at NBOE facilities. The

Newark Board of Education reserves the right to assign representatives of the Newark Board of Education to visit locations now serviced by the Bidder.

D2.3 A minimum of five (5) years’ experience providing similar services in size and scope are required.

D2.4 For this bid, the Contractor performing public works for the Newark Board of Education shall be required to pay the established wage and fringe benefit rates as guided by New Jersey Department of Labor and

Workforce Development Prevailing Wage rate for the craft of Boilermaker.

D2.5 Bidders must be pre-qualified with the State of New Jersey, Department of Property Management and

Construction (DPMC) in one the following classifications:

C039 - HVAC

C033 - Boilers - New/Repair

D2.6 Welders shall have a NJ R-Stamp certified welding license.

D2.7 All workmanship/performance will be evaluated on the basis of a review of their work performed for each job assigned. The Newark Board of Education must receive service that is consistently rated “above average”.

D3 BASIS OF AWARD AND CONTRACT TERM

D3.1 Award of contract will be made to the lowest responsible and responsive Bidder.

D3.2 This contract is for two (2) years from date of award with an option to renew for one (1) successive two

(2) year period. There will be no increase in price during the contract period. Pricing on all services shall remain as submitted unless discounted. The final contract shall represent the terms and conditions of the agreement. Renewals may be exercised by the District in its sole discretion. By submitting a bid, the awarded contractor agrees to a maximum contract term of four (4) years. January 1, 2027 through December 31, 2028 is the anticipated initial contract term.

D3.3 This contract is not funded in itself. Funding will be provided by the issuance of a purchase order. No legal liability on the part of the District for any payment may arise until the contract is funded by issuance of a purchase order. Only a purchase order authorizes the performance of services or delivery of goods. The District is not responsible for services performed or goods delivered without an authorized Purchase Order.

D3.4 The Board shall not be obligated to any minimum expenditures. The final contract will be based on the actual work assigned and performed.

D3.5 The NBOE District reserves the right to extend the ordering period for an additional ninety (90) days beyond the contract expiration date upon written notification to the vendor thirty (30) days prior to the contract expiration date with no increase in price.

D4 PRICES

D4.1 Pricing shall be entered in the Pricing - Enter Bids segment of the electronic bidding platform http://www.npsourcing.com .

D4.2 All prices will be firm and not subject to increase. All prices bid are to include a margin for the contractor which is to include, but not be limited to, overhead, administrative costs and profit.

D4.3 Labor prices quoted are to remain firm for the period of the contract. Labor prices are to include travel time, mileage and tolls. No separate billing will be allowed for travel time, mileage and/or tolls.

D4.4 Any supervision provided by the Contractor will be at the expense of the Contractor unless the supervisor is an active participant in the service/repair or replacement work. At which point the Contractor is entitled to the awarded rate.

D5 QUOTATIONS AND INVOICES

Quotations

D5.1 When the need for services arise the awarded Contractor will be contacted to perform a site visit for generation of a quote. A site visit is required for generation of all quotes and shall be free of charge. All quotes shall be provided via email, and itemized to identify the following:

− The Contractor’s complete business name, address, and contact information

− Contract number 10285

− School’s name and address

− Vendor’s quotation number

− Detailed work to be performed

− Part Cost

− Part Markup Percentage

− Quantity of Labor Hours and Labor Rates

− Labor Hours needed for project completion

Invoicing

D5.2 During the life of the contract, the Contractor will be paid for actual work assigned and performed. All invoices must specify:

- The Contractor’s complete business name, address, and contact information

- Purchase order number

- Service date

- Service location

- Service description

- Contracted rates

- Service start date and completion date

- Contract number 10285

- A unique invoice number (all invoices cannot have the same number)

- Invoice date

D5.3 Payments WILL NOT be approved until an authorized Facilities Management Representative inspects and approves the completed work.

D5.4 The District’s payment terms of net 30 days begin once the Contractor has provided their signed purchase order voucher and invoice to the Office of Facilities Management. The Contractor shall have sole responsibility for the complete effort specified in the contract. Payment will be made only to the Contractor. The Contractor shall have sole responsibility for any and all payments due to any subcontractor.

D5.5 The Board reserves the right to delete any item from the Contractor’s invoice that reflects items and or services not awarded under this solicitation and to amend any price that reflects a cost higher than the contracted price.

D5.6 Payments will not be issued for any equipment, materials, service and/or repairs not covered under this contract.

D5.7 Payments shall not preclude the District form making a claim adjustment on any item later found not to have been in accordance with this contract.

D5.8 The District will review the cost for materials and parts billed to assure the pricing is within industry standards.

The District shall have the absolute right, at any time, to request documentation-verifying Contractor’s cost for materials or parts billed. Documentation requests are not limited to the Contractor’s supplier invoice.

D6 NEW JERSEY PREVAILING WAGE ACT

D6.1 Pursuant to N.J.S.A. 34:11-56.25 et seq, contractors on projects for public work shall adhere to all requirements of the New Jersey Prevailing Wage Act. The Contractor shall be required to submit a certified payroll record to the owner within ten (10) days of the payment of wages. The Contractor is also responsible for obtaining and submitting all subcontractors’ certified payroll records within the aforementioned time period. The Contractor shall submit said certified payrolls in the form set forth in N.J.A.C. 12:60-6.1(c). It is the Contractor’s responsibility to obtain any additional copies of the certified payroll form to be submitted by contacting the New

Jersey Department of Labor and Workforce Development, Division of Workplace Standards. Additional information is available at https://www.nj.gov/labor/wagehour/wagerate/wage_rates.html.

Attached hereto and incorporated herein are the Department of Labor and Workforce Development prevailing wage determination(s) for the locality and craft(s) that will be employed in the performance of work under this contract. It is hereby stipulated that each individual who performs work under this contract shall be paid not less than the prevailing wage rate to which that worker is entitled under the

New Jersey Prevailing Wage Act, as reflected in the appropriate Department of Labor and Workforce

Development prevailing wage determination.

In the event it is found that any worker employed by the Contractor or any subcontractor covered by this contract has been paid a rate of wages less than the prevailing wage rate required to be paid by this contract, the public body, the lessee to whom the public body is leasing a property or premises or the lessor from whom the public body is leasing or will be leasing a property or premises may terminate the

Contractor's or subcontractor's right to proceed with the work, or such part of the work as to which there has been a failure to pay required wages, and to prosecute the work to completion or otherwise. The

Contractor and his sureties shall be liable to the public body, any lessee to whom the public body is leasing a property or premises, or to any lessor from whom the public body is leasing or will be leasing a property or premises for any excess costs occasioned by the termination of the Contractor's or subcontractor's right to proceed with the work, or such part of the work as to which there has been a failure to pay required wages.

Certified Payroll Requirements

D6.2 This project shall be deemed as a prevailing wage project and all necessary documentation shall be included, but not limited to weekly certified payrolls which are to be addressed to Newark Board of Education, Office of

Facilities Management, 190 Muhammad Ali Avenue, Newark, NJ 07108 for the entire length of the work under this contract.

D6.3 This project shall abide to any/all prevailing wage rates for the State of New Jersey. All requirements for latest published prevailing wage standards shall be the responsibility of the bidding firm.

D7 NEW JERSEY PUBLIC WORKS CONTRACTOR REGISTRATION ACT

D7.1 The Public Works Contractor Registration Act (PWCRA), N.J.S.A. 34:11-56.48 et seq. requires that the bidder, including named subcontractors, register with the Department of Labor and Workforce Development prior to submitting price proposals or engaging on certain public works contracts that exceed the prevailing wage threshold.

D8 BID BOND AND PERFORMANCE BOND

D8.1 Bid bond/security required, see Section F, paragraph F1.1.

D8.2 Performance bond required, see Section F, paragraph F2.1, F3.1 and F3.2.

D9 LIQUIDATED DAMAGES

D9.1 Should the Contractor fail to make deliveries and/or services as specified; there will be a deduction from the amount due him/her, in the sum of two hundred fifty dollars ($250.00) per day, for each affected location. Such sum shall be treated as liquidated damages and not as a penalty.

D9.2 The Contractor must immediately advise the NBOE representative(s) of any circumstances and/or events that could result in late completion of any task or subtask called for to be completed on a certain date. Notification must also be provided to the Director of Support Services at the address below:

The Newark Board of Education

Department of Purchasing Attention: Director of Support Services

765 Broad Street

Newark, New Jersey 07102

D10 DAMAGE TO PROPERTY

D10.1 The Contractor shall be responsible for any damage caused by the Contractor to NBOE property.

D10.2 If any property owned or occupied by NBOE and/or other property within the Contractor’s work area is damaged by the equipment or employees of the party to whom a contract for boiler settings, relining and repair services has been awarded, the Contractor shall be liable for the cost of the repairs necessary on account of such damage, and the NBOE reserves the right to deduct such cost from any sums that may be due or become due to the Contractor.

D10.3 In the event it becomes necessary for the NBOE to remedy or provide for remedial action in any damaged area, the cost will be deducted from any monies due the Contractor. If there are no monies due, a claim may be submitted to the Contractor’s bonding company. It is recommended that delivery trucks be equipped with appropriate clean-up materials, i.e., absorbent pads, sand, shovel, containers, etc., with which the driver may cleanup and remove any residual materials.

D10.4 In the event the Contractor fails to comply with any of the conditions herein provided and as covered by the contract, the Director of Support Services may notify the Contractor of such failure or default, and demand that the problem be remedied within a reasonable time under the circumstances, but in no event, more than two (2) days.

D10.5 In the event of the failure by Contractor to remedy the same within said time period, the Director of Support

Services may take steps to terminate the contract in accordance with the contract agreement. In that event, the

Director of Support Services will authorize the service to be performed by any available means, the difference between the actual cost paid and the bid of the defaulting Contractor shall be deducted from any monies due to the defaulting Contractor.

D11 NBOE’S RIGHT TO TERMINATE OR AMEND CONTRACT(S) AS A RESULT OF THE ANTICIPATED

IMPLEMENTATION OF ENERGY CONSERVATION CONTRACT(S)

D11.1 The NBOE is actively proceeding with a plan for comprehensive energy management and energy capital improvement services, which may include but not be limited to energy audit, design, acquisition installation, modification and/or maintenance of existing and new equipment and controls for all heating, ventilation, and air conditioning, and lighting systems.

D11.2 At any time during the course of the initial two-year term contract, or at any time during any subsequent renewal, the NBOE reserves the right to terminate or amend the contract(s) to remove sites and/or limit the services to be performed at specific sites at our option without penalty to the Board.

D12 CANCELLATION FOR CONVENIENCE

D12.1 NBOE reserves the right to terminate any contract entered into at any time for convenience provided written notice has been given by the Director of Support Services at least ten (10) days prior to such proposed termination date.

D12.2 In the event services end by either contract expiration or termination, it shall be incumbent upon the Vendor to continue services, if requested by the Director of Support Services, until new contract can be completely operational. The vendor acknowledges its responsibility to cooperate fully with the replacement vendor and the

Newark Board of Education to ensure a smooth and timely transition to the replacement vendor. Such transitional period shall not extend more than ninety (90) days beyond the expiration date of the contract, or any extension thereof. The vendor will be reimbursed for services during the transitional period at the rate in effect when the transitional period clause is invoked by the Newark Board of Education.

D13 INSURANCE

D13.1 Insurance is required. The minimum scope and limits of insurance shall include

(i) Comprehensive General Liability Insurance including Product Liability Insurance covering bodily injury, personal injury and property damage. Limits of Liability shall be not less than $1,000,000 Combined

Single Limit;

(ii) Workers’ Compensation and Employers Liability Insurance as required by the State Law of New Jersey;

(iii) Commercial Automobile Liability Insurance, with limits of liability not less than $1,000,000 Combined

Single Limit; and

Contractor shall provide and maintain Installation Floater Insurance insuring against damage or destruction of the material and/or equipment in transit to, or stored on or off the project site which is to be used in the work.

The Newark Board of Education is to be added as an additional insured; as our interest may appear on all

Certificates of Insurance.

765 Broad Street

Newark, NJ 07102

In the event that the contractor fails to maintain or renew any insurance coverage during the period of the contract, the NBOE may cancel the contract at that time without any prior notification. No insurance policy issued for this contract may be allowed to expire prior to the completion of this contract without first providing the District with at least fifteen (15 days) advance notice before the expiration by certified mail.

Owner’s Liability Insurance. The Owner shall be responsible for and at their option may maintain such insurance as will protect them from their contingent liability for damages for personal injury including death, which may arise from operations under this contract.

D13.2 The Contractor shall be one hundred percent (100%) responsible for the repair or replacement of any merchandise or property damaged. The NBOE’s appointed representative will determine all valuations. Failure to remit payment for damages will result in a deduction of monies due by the District from any/all sum(s) remaining to be paid under the Contract.

D14 DEBARMENT

D14.1 Firms listed on the state and federal debarment list are prohibited from doing business with the Newark Board of

Education.

D15 GUARANTEE

D15.1 The bidder shall guarantee any or all goods and services supplied under these specifications to be free from defects for one (1) year from delivery. Items showing defect shall immediately be replaced within seven (7) days at no additional cost to the NBOE. If any product fails to perform under normal use, are determined to be defective and/or inferior, the Contractor shall replace the items at no cost to the NBOE. The bidder will be responsible for return freight and any related fees including restocking charges.

D15.2 Standard Manufacturer warranty shall apply. By submitting a bid, the bidder expressly warrants that the goods covered by the contract shall conform to the specifications or other description furnished or as specified by the

NBOE; be merchantable and fit for the purpose intended; and shall be free from defects including during shipment.

D15.3 Bidders shall represent that all goods, materials, supplies, or components, offered to the NBOE under this solicitation are new, not used or reconditioned, and are not of such age or so deteriorated as to impair the usefulness. All products shall be covered by the most favorable commercial warranty.

D15.4 The Contractor shall promptly replace any faulty products, without cost to the NBOE and with the understanding that all replacements shall be NEW and carry the same warranty as the original equipment.

D16 PRODUCT RECALL

D16.1 The Contractor shall assume full responsibility for prompt notification to the District of any product recall in accordance with the applicable state or federal regulations.

SCHOOL & EQUIPMENT MAKE MODEL # SERIAL # YEAR BURNER FUEL MBTU

GENERAL PERMIT # W/

EXPIRATION

ABINGTON I.D. 08353

BOILER 1 HB Smith 28HE-18 193453 2020 POWER FLAME GAS 5.5 GP018 2028

BOILER 2 HB Smith 28HE-18 193455 2020 POWER FLAME GAS 5.5 GP018 2028

ALEXANDER I.D. 05395

BOILER 1 CLEAVER BROOKS FLX-700-500 013465-1-1 2017 CB GAS 5 GP018 2028

BOILER 2 CLEAVER BROOKS FLX-700-500 013465-1-2 2017 CB GAS 5 GP018 2028

AMERICAN HISTORY I.D. 06508

BOILER 1 EASTMOND PLW265SP 11932 2003 POWERFLAME GAS 11.8 GP009A 2019

BOILER 2 EASTMOND PLW265SP 11933 2003 POWERFLAME GAS 11.8 GP009A 2019

ANN STREET I.D. 08347

BOILER 1 WEIL MCLAIN 1188 L52733 2017 POWERFLAME GAS 3.4 GP017 2028

BOILER 2 WEIL MCLAIN 1188 L52734 2017 POWERFLAME GAS 3.4 GP017 2028

BOILER 3 WEIL MCLAIN 1188 L52735 2017 POWERFLAME GAS 3.4 GP017 2028

ARTS I.D. 08332

BOILER 1 CLEAVER BROOKS FLX-700-500 12784-1-2 2018 CB GAS 5 GP018 2028

BOILER 2 CLEAVER BROOKS FLX-700-500 12784-1-3 2018 CB GAS 5 GP018 2028

BOILER 3 CLEAVER BROOKS FLX-700-500 12784-1-1 2018 CB GAS 5 GP018 2028

AVON I.D. 08328

BOILER 1 WEIL MCLAIN 1888 CP7735405 2019 POWERFLAME GAS 5.8 GP018 2028

BOILER 2 WEIL MCLAIN 1888 CP7735410 2019 POWERFLAME GAS 5.8 GP018 2028

BOILER 3 WEIL MCLAIN 1888 CP7735404 2019 POWERFLAME GAS 5.8 GP018 2028

BARRINGER I.D. 08351

BOILER 1 AERCO BMK-3000 G-16-2184 2017 AERCO GAS 3 GP017 2025

BOILER 2 AERCO BMK-3000 G-16-2058 2017 AERCO GAS 3 GP017 2025

BOILER 3 AERCO BMK-3000 G-16-2181 2017 AERCO GAS 3 GP017 2025

BOILER 4 AERCO BMK-3000 G-16-2248 2017 AERCO GAS 3 GP017 2025

BOILER 5 AERCO BMK-3000 G-16-2064 2017 AERCO GAS 3 GP017 2025

GLOBAL STUDIES/GHJ I.D. 08383

BOILER 1 AERCO BMK-3000 2022 AERCO GAS 4 GP017 2028

BOILER 2 AERCO BMK-3000 2022 AERCO GAS 4 GP017 2028

BELMONT RUNYON I.D. 08348

BOILER 1 WEIL-MCLAIN 1698 blr1 2003 POWER FLAME GAS 6.5 GP018 2028

BOILER 2 WEIL-MCLAIN 1698 blr2 2003 POWER FLAME GAS 6.5 GP018 2028

BERLINER NO BOILERS

BOYLAN I.D. 08381 BLDG SHUT DOWN 2016

BOILER 1 WEIL MCLAIN 688 BLR-1 2004 POWERFLAME GAS 2 GP017 2014

BOILER 2 WEIL MCLAIN 688 BLR-2 2004 POWERFLAME GAS 2 GP017 2014

BOILER 3 WEIL MCLAIN 688 BLR-3 2004 POWERFLAME GAS 2 GP017 2014

BRAGAW I.D. 05079

BOILER 1 CONTINENTAL CON250 BLR-1 1975 GORDON PIATT GAS 8.4 GP018 2028

BOILER 2 EASCO FST-200 15250 2016 POWERFLAME GAS 8.4 GP018 2028

BRANCH BROOK I.D. 08365

BOILER 1 HB SMITH 888 2015 POWERFLAME GAS 2.3 GP017 2028

BOILER 2 HB SMITH 888 2015 POWERFLAME GAS 2.3 GP017 2028

GW CARVER I.D. 08333

BOILER 1 AERCO BMK-3000 G-16-2036 2017 AERCO GAS 3 GP017 2028

BOILER 2 AERCO BMK-3000 G-16-2238 2017 AERCO GAS 3 GP017 2028

BOILER 3 AERCO BMK-3000 G-16-2057 2017 AERCO GAS 3 GP017 2028

BOILER 4 AERCO BMK-3000 G-16-2182 2017 AERCO GAS 3 GP017 2028

BARD I.D. 08349

BOILER 1 RBI

33FB1905NR2AI

PS

70332534 2000 RBI GAS 1.95 GP017 2028

BOILER 2 RBI FB1950 41982581 2019 RBI GAS 1.95 GP017 2028

BOILER 3 RBI

33FB1905NR2AI

PS

70332520 2000 RBI GAS 1.95 GP017 2028

Attachment A - Boiler Inventory

EXPIRATION

BOILER 4 RBI

33FB1905NR2AI

PS

70332526 2000 RBI GAS 1.95 GP017 2028

BOILER 5 RBI

33FB1905NR2AI

PS

70332521 2000 RBI GAS 1.95 GP017 2028

BOILER 6 RBI

33FB1905NR2AI

PS

70332533 2000 RBI GAS 1.95 GP017 2028

BOILER 7 RBI

33FB1905NR2AI

PS

70332525 2000 RBI GAS 1.95 GP017 2028

BOILER 8 RBI FB1950 41982592 2019 RBI GAS 1.95 GP017 2028

CAMDEN ST I.D. 05083

BOILER 1 PATERSON KELLY 1900 18-94-4112 2015 PK GAS 1.5 GP017 2028

BOILER 2 PATERSON KELLY 1900 11-94-3944 2015 PK GAS 1.5 GP017 2028

BOILER 3 PATERSON KELLY 1900 18-94-4111 2015 PK GAS 1.5 GP017 2028

BOILER 4 PATERSON KELLY 1900 19-94-4158 2015 PK GAS 1.5 GP017 2028

BOILER 5 PATERSON KELLY 1900 19-94-4159 2015 PK GAS 1.5 GP017 2028

BOILER 6 PATERSON KELLY 1900 19-94-4160 2015 PK GAS 1.5 GP017 2028

CENTRAL HS I.D. 08311

HWH 1 AO SMITH BTP300-1000000 SLO4106369 Y3 2006 AOS GAS 1 GP017 2028

HWH 2 AO SMITH BTP300-1000000 SLO4106326 Y3 2006 AOS GAS 1 GP017 2028

HWH 3 AO SMITH BTP300-1000000 SLO4106368 Y3 2006 AOS GAS 1 GP017 2028

CHANCELLOR AVE I.D. 06274

BOILER 1 WEIL MCLAIN 1294 BLR1 2022 powerflame GAS 5.3 GP018 2028

BOILER 2 WEIL MCLAIN 1294 BLR2 2022 powerflame GAS 5.3 GP018 2028

CHANCELLOR ANNEX I.D. 08367

BOILER 1 BURNHAM EL-80 23432 1995 ICA GAS 3.5 GP017 2028

BOILER 2 BURNHAM EL-80 23460 1995 ICA GAS 3.5 GP017 2028

CLEMENTE I.D. 08346

BOILER 1 WEIL MCLAIN 1294 BLR1 1975 GORDON PIATT GAS 8.4 GP018 2028

BOILER 2 WEIL MCLAIN 1294 BLR2 1975 GORDON PIATT GAS 8.4 GP018 2028

CLEVELAND I.D. 05399

BOILER 1 HB SMITH JB3G-77-YB110 U95977A-01 2011 CYCLONETTIC GAS 8.3 GP018 2025

BOILER 2 HB SMITH JB3G-77-YB110 U95977A-02 2011 CYCLONETTIC GAS 8.3 GP018 2025

DAYTON I.D. 08350 BLDG SHUT DOWN 2015

BOILER 1 CLEAVER BROOKS CBXXX-250 L89818 1991 CB GAS 8.3 GP018 2014

BOILER 2 CLEAVER BROOKS CBXXX-250 L89817 1991 CB GAS 8.3 GP018 2014

EAST SIDE I.D. 08331

BOILER 1 AERCO BMK-5000 2022 AERCO GAS 5 GP018 2028

BOILER 2 AERCO BMK-5000 2022 AERCO GAS 5 GP018 2028

BOILER 3 AERCO BMK-5000 2022 AERCO GAS 5 GP018 2028

BOILER 4 WEIL MCLAIN 1594 BLR1 2022 POWERFLAME GAS 7.2 GP018 2028

BOILER 5 WEIL MCLAIN 1594 BLR2 2022 POWERFLAME GAS 7.2 GP018 2028

N 10

TH

ST/URENA I.D. 08376

BOILER 1 WEIL MCLAIN 1294 BLR1 2022 POWERFLAME GAS 5.4 GP018 2028

BOILER 2 WEIL MCLAIN 1294 BLR2 2022 POWERFLAME GAS 5.4 GP018 2028

FIRST AVE I.D. 08258

BOILER 1 FULTON PHW-1400 183 2007 FULTON GAS 1.5 GP017 2028

BOILER 2 FULTON PHW-1400 184 2007 FULTON GAS 1.5 GP017 2028

BOILER 3 FULTON PHW-2000 118 2007 FULTON GAS 2 GP017 2028

BOILER 4 FULTON PHW-2000 200 2007 FULTON GAS 2 GP017 2028

EXPIRATION

BOILER 5 FULTON PHW-2000 116 2007 FULTON GAS 2 GP017 2028

15TH AVE I.D. 06543 BLDG SHUT DOWN 2016

BOILER 1 CLEAVER BROOKS CB700-200 L91019 1992 CB GAS 8.4 GP018 2014

BOILER 2 CLEAVER BROOKS CB700-200 L91020 1992 CB GAS 8.4 GP018 2014

14TH AVE/OBAMA I.D. 06669

BOILER 1 WEIL MCLAIN 1188 1 2017 POWERFLAME GAS 3.4 GP017 2028

BOILER 2 WEIL MCLAIN 1188 2 2017 POWERFLAME GAS 3.4 GP017 2028

BOILER 3 WEIL MCLAIN 1188 3 2017 POWERFLAME GAS 3.4 GP017 2028

FLAGG N/A

BOILER 1 AERCO BMK-3000 2022 AERCO Gas 3 GP017

BOILER 2 AERCO BMK-1500 2022 AERCO gas 1.5 GP017

FRANKLIN I.D. 08354

BOILER 1 WEIL MCLAIN 1294 BLR1 2024 POWERFLAME GAS 5.2 GP018

BOILER 2 WEIL MCLAIN 1294 BLR2 2024 POWERFLAME GAS 5.2 GP018

HAROLD WILSON N/A

BOILER 1 AERCO BMK-3000 2024 AERCO Gas 3 GP017

BOILER 2 AERCO BMK-3000 2024 AERCO Gas 3 GP017

HAWKINS I.D. 05516

BOILER 1 HB SMITH 28HE12 132219 2013 POWER FLAME GAS 3.7 GP017 2028

BOILER 2 HB SMITH 28HE12 132220 2013 POWER FLAME GAS 3.7 GP017 2028

HAWTHORNE I.D. 06692

BOILER 1 EASCO FST-175 12939 2006 POWERFLAME GAS 7.3 GP018 2028

BOILER 2 EASCO FST-175 12940 2006 POWERFLAME GAS 7.3 GP018 2028

HERNANDEZ NO HWH OR BOILER I.D. 08389

HORTON I.D. 08370

BOILER 1 AERCO BMK-3000 G-20-1711 2020 AERCO GAS 3 GP017 2028

BOILER 2 AERCO BMK-3000 G-20-1709 2020 AERCO GAS 3 GP017 2028

BOILER 3 AERCO BMK-3000 G-20-1708 2020 AERCO GAS 3 GP017 2028

BOILER 4 AERCO BMK-3000 G-20-1712 2020 AERCO GAS 3 GP017 2028

BOILER 5 AERCO BMK-3000 G-20-1710 2020 AERCO GAS 3 GP017 2028

JFK I.D. 06183

BOILER 1 PATERSON KELLY NM-1500 CL21-03-25003 2003 PK GAS 1.5 GP017 2028

BOILER 2 PATERSON KELLY NM-1500 CL21-03-25003 2003 PK GAS 1.5 GP017 2028

BOILER 3 PATERSON KELLY NM-1500 CL14-05-24802 2003 PK GAS 1.5 GP017 2028

MLK I.D. 08372

BOILER 1 HB SMITH JB3G-75-YB110 U95976A-02 2011 CYCLONETTIC GAS 8.8 GP018 2014

BOILER 2 HB SMITH JB3G-75-YB110 U95977A-02 2011 CYCLONETTIC GAS 8.8 GP018 2014

LAFAYETTE I.D. 05403

BOILER 1 WIEL MCLAIN 1294 BLR1 2022 POWERFLAME gas 8.8 GP018 2028

BOILER 2 WIEL MCLAIN 1294 BLR2 2022 POWERFLAME gas 8.8 GP018 2028

LAFAYETTE ANNEX NOT OWNERS

BOILER 1 HB SMITH 19HE-07 114117 2005 POWER FLAME 2 OIL 1.1 GP017 2014

LINCOLN I.D. 06371

BOILER 1 CLEAVER BROOKS CB700-125 L94698 1995 CB GAS 5.2 GP018 2028

BOILER 2 CLEAVER BROOKS CB700-125 L94692 1995 CB GAS 5.2 GP018 2028

MADISON I.D. 05404

BOILER 1 CLEAVER BROOKS CB800-200 L55133 1973 CB GAS 8.4 GP018 2028

BOILER 2 CLEAVER BROOKS CB800-200 L55134 1973 CB GAS 8.4 GP018 2028

MARIN I.D. 06729

BOILER 1 CLEAVER BROOKS CB700-125 L94684 1995 CB GAS 5.2 GP018 2028

BOILER 2 CLEAVER BROOKS CB700-125 L94695 1995 CB GAS 5.2 GP018 2028

BOILER 3 CLEAVER BROOKS CB600-125 L89242 1990 CB GAS 5.2 GP018 2028

McKINLEY I.D. 08334

BOILER 1 AERCO BMK-3000 2022 AERCO GAS 3 GP017 2028

EXPIRATION

BOILER 2 AERCO BMK-3000 2022 AERCO GAS 3 GP017 2028

BOILER 3 AERCO BMK-3000 2022 AERCO GAS 3 GP017 2028

MOUNT VERNON I.D. 08374

BOILER 1 WEIL MCLAIN 94 BLR-1 2000 POWERFLAME GAS 6.5 GP018 2028

BOILER 2 WEIL MCLAIN 94 BLR-2 2000 POWERFLAME GAS 6.5 GP018 2028

BOILER 3 WEIL MCLAIN 94 BLR-3 2003 POWERFLAME GAS 6.5 GP018 2028

NEWARK VOCATIONAL I.D. 06718

BOILER 1 AERCO BMK-3000 G-20-2714 2021 AERCO GAS 3 GP017 2028

BOILER 2 AERCO BMK-3000 G-20-2715 2021 AERCO GAS 3 GP017 2028

BOILER 3 AERCO BMK-3000 G-20-2713 2021 AERCO GAS 3 GP017 2028

BOILER 4 AERCO BMK-3000 G-20-2712 2021 AERCO GAS 3 GP017 2028

NEWTON I.D. 05985

BOILER 1 WEIL-MCLAIN 1888 L52733 2015 POWER FLAME GAS 5.8 GP018 2028

BOILER 2 WEIL-MCLAIN 1888 L52735 2015 POWER FLAME GAS 5.8 GP018 2028

EAST WARD I.D. 08377

BOILER 1 WEIL MCLAIN 1388 1 2019 POWERFLAME GAS 4.2 GP017 2028

BOILER 2 WEIL MCLAIN 1388 2 2019 POWERFLAME GAS 4.2 GP017 2028

BOILER 3 WEIL MCLAIN 1388 3 2019 POWERFLAME GAS 4.2 GP017 2028

PARK I.D. 09100

BOILER 1 RBI FUTERA MB1500 80850766 2009 RBI GAS 1.5 GP017 2028

BOILER 2 RBI FUTERA MB1500 80850736 2009 RBI GAS 1.5 GP017 2028

BOILER 3 RBI FUTERA MB1500 80850743 2009 RBI GAS 1.5 GP017 2028

HWH AO SMITH HWH1 ---------- 2009 AOSMITH GAS 1.8 GP017 2028

PESHINE I.D. 08018

BOILER 1 WEIL MCLAIN LN1CR4-G-30 110310959 2004 POWERFLAME GAS 5.2 GP018 2028

BOILER 2 WEIL MCLAIN LN1CR4-G-30 110310958 2004 POWERFLAME GAS 5.2 GP018 2028

BOILER 3 WEIL MCLAIN LN1CR4-G-30 110310957 2004 POWERFLAME GAS 5.2 GP018 2028

QUITMAN I.D. 08379

BOILER 1 PATERSON KELLY N1900 CJ268224 1997 PK GAS 1.9 GP017 2028

BOILER 2 PATERSON KELLY N1900 CJ268225 1997 PK GAS 1.9 GP017 2028

BOILER 3 PATERSON KELLY N1900 CJ268226 1997 PK GAS 1.9 GP017 2028

BOILER 4 PATERSON KELLY N1900 CJ268227 1997 PK GAS 1.9 GP017 2028

BOILER 5 PATERSON KELLY N1900 CJ268228 1997 PK GAS 1.9 GP017 2028

BOILER 6 PATERSON KELLY N1900 CJ268229 1997 PK GAS 1.9 GP017 2028

RIDGE ST I.D. 06272

BOILER 1 HB SMITH 28HE-11 132177 2013 POWERFLAME GAS 3.4 GP017 2028

BOILER 2 HB SMITH 28HE-11 132178 2013 POWERFLAME GAS 3.4 GP017 2028

RIDGE ECC I.D. 07749

BOILER 1 HB SMITH 28A-14 N96-647 1996 POWERFLAME GAS 2.76 GP017 2028

ROSEVILLE NOT OWNER

BOILER 1 WEIL MCLAIN 1188 110312263 2004 POWERFLAME GAS 3.4 GP017 2014

BOILER 2 WEIL MCLAIN 1188 110312263 2004 POWERFLAME GAS 3.4 GP017 2014

SCIENCE PARK I.D. 08352

BOILER 1 AERCO BENCH 2.0 G-04-1277 2005 AERCO GAS 2 GP017 2028

BOILER 2 AERCO BENCH 2.0 G-04-1280 2005 AERCO GAS 2 GP017 2028

BOILER 3 AERCO BENCH 2.0 G-04-1278 2005 AERCO GAS 2 GP017 2028

BOILER 4 AERCO BENCH 2.0 G-04-1279 2005 AERCO GAS 2 GP017 2028

HWH 1 RECO R60-1569-FG T-19966 TK1 2005 RECO GAS 1.3 GP017 2028

HWH 2 RECO R60-1569-FG T-19966 TK2 2005 RECO GAS 1.3 GP017 2028

SCHOOL STADIUM I.D. 09101

HWH LOCKER RM PVI 0.5 N/A

HWH CONCESSION PVI 0.75 N/A

SHABAZZ I.D. 08336

BOILER 1 CLEAVER BROOKS FLX-700-700 SNS61517-1 2018 CB GAS 7.6 GP018 2028

BOILER 2 CLEAVER BROOKS FLX-700-700 SNS61517-3 2018 CB GAS 7.6 GP018 2028

BOILER 3 CLEAVER BROOKS FLX-700-700 SNS61517-2 2018 CB GAS 7.6 GP018 2028

EXPIRATION

SPEEDWAY I.D. O9102

BOILER 1 FULTON

PAW-140000M-

BLR-1 2009 FULTON GAS 3.5 GP017 2028

BOILER 2 FULTON

PAW-140000M-

BLR-2 2009 FULTON GAS 3.5 GP017 2028

BOILER 3 FULTON

PAW-140000M-

BLR-3 2009 FULTON GAS 3.5 GP017 2028

OLD SPEEDWAY/14th Ave I.D. 08121

BOILER 1 WEIL MCLAIN 788 BLR-1 2004 POWERFLAME GAS 2.2 GP017 2028

BOILER 2 WEIL MCLAIN 788 BLR-2 2004 POWERFLAME GAS 2.2 GP017 2028

BOILER 3 WEIL MCLAIN 788 BLR-3 2004 POWERFLAME GAS 2.2 GP017 2028

SPENCER I.D. 08327

BOILER 1 AERCO BENCH 4.0 2024 AERCO GAS 4 GP017 2028

BOILER 2 AERCO BENCH 4.0 2024 AERCO GAS 4 GP017 2028

BOILER 3 AERCO BENCH 4.0 2024 AERCO GAS 4 GP017 2028

BOILER 4 AERCO BENCH 4.0 2024 AERCO GAS 4 GP017 2028

S 17TH ST I.D. 08362

BOILER 1 FEDERAL FST-150 9331 1997 ICA GAS 6.3 GP018 2028

BOILER 2 FEDERAL FST-150 9330 1997 ICA GAS 6.3 GP018 2028

SOUTH ST [OLD] BDLG SHUT DOWN 2016

BOILER 1 BURNHAM EL80 9014753 1995 ICA GAS 3.5 GP017 2014

BOILER 2 BURNHAM EL80 9014754 1995 ICA GAS 3.5 GP017 2014

SUSSEX I.D. 09036

BOILER 1 HB SMITH 28HE9 132144 2013 POWER FLAME GAS 2.5 GP017 2028

BOILER 2 HB SMITH 28HE9 132144 2013 POWER FLAME GAS 2.5 GP017 2028

STUDENT CENTER N/A

BOILER 1 LOCHNIVAR 2022 LOCHNIVAR GAS 0.75 N/A

BOILER 2 LOCHNIVAR 2022 LOCHNIVAR GAS 0.75 N/A

BOILER 3 LOCHNIVAR 2022 LOCHNIVAR GAS 0.75 N/A

TECHNOLOGY I.D. 08357

BOILER 1 CLEAVER BROOKS CB1200200015 0L10L2287 2003 CB GAS 8.16 GP018 2028

BOILER…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .