New_Construction_Permit_5801_Frank_Pittman_Rd_Gomez_.pdf

PDF 3 MB Posted

Attached to
Housing Reconstruction-5801 Frank Pittman Road
Solicitation number
26-049
Issued by
Santa Rosa County, Mount Carmel CDP, Florida

About this file

This file consists of a Florida Department of Environmental Protection (FDEP) Onsite Sewage Treatment and Disposal System (OSTDS) Construction Permit and a related Santa Rosa County housing reconstruction solicitation. The OSTDS permit (No. 57-S0-5174784) authorizes the installation of a new 900-gallon septic tank system with a 308 square foot drainfield at 5801 Frank Pittman Road, Milton, Florida. The system is designed for a 2-bedroom residence with a maximum occupancy of 4 persons and an estimated daily flow of 200 gallons per day. The permit was issued on June 18, 2026, with an expiration date of December 18, 2027. The applicant, Guy Gomez, must complete the installation in accordance with Florida Statutes Section 381.0065 and Florida Administrative Code Chapter 62-6, including abandonment of the existing noncertified tank and maintenance of all required setbacks (75 feet to private well and surface water). The permit includes specifications for trench-type drainfield construction with a benchmark reference point and elevation requirements.

Santa Rosa County's companion procurement (26-049) solicits sealed bids for housing reconstruction at the same property address. A mandatory pre-bid meeting is scheduled for July 30, 2026, at 9:30 a.m. at the project site. Specifications are available through the Santa Rosa County Procurement Portal. Questions must be submitted by 12:00 p.m. on Thursday, August 6, 2026, and sealed bid proposals are due by 10:30 a.m. on Thursday, August 13, 2026, with public opening to follow. Santa Rosa County encourages participation from small businesses, minority and women-owned businesses, and disadvantaged business enterprises and reserves the right to waive irregularities, reject any or all bids, and award to the bid determined to be in the county's best interest.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STATE OF FLORIDA

DEPARTMENT OF ENVIRONMENTAL PROTECTION

ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM (OSTDS)

CONSTRUCTION PERMIT

Permit No. 57-S0-5174784 Application No. AP4296799

Date Paid:

Fee Paid:

Receipt No.

Document No. PR4307544

Facility ID. 57-5174784

Type [ X ] New System [ ] Existing System Modification [ ] Repair [ ] Abandonment [ ] Temporary

Subtype [ ] Aerobic Treatment Unit [ ] Non-Innovative PBTS [ ] Innovative PBTS [ ] Innovative Non PBTS [ ] Holding Tank [ ] Other (describe)

Applicant: Guy Gomez

Property Address: 5801 Frank Pittman Rd City Milton State FL Zip 32570

Lot: N/A Block: N/A Subdivision: METES & BOUNDS

Property ID No. 01-5N-27-0000-00603-0000 [Section, Township, Range, Parcel Number, or Tax ID No.]

The system must be constructed in accordance with specifications and standards of Section 381.0065, F.S., and Chapter 62-6, F.A.C.

Department approval of system does not guarantee satisfactory performance for any specific period of time. Any change in material facts, which served as a basis for issuance of this permit, require the applicant to amend the permit application. Such amendments may result in voiding this permit. Issuance of this permit does not exempt the applicant from compliance with other federal, state, or local permitting required for development of this property.

SYSTEM DESIGN AND SPECIFICATIONS

Tank

900 Gallons / GPD capacity [ X ] Septic Tank [ ] Aerobic Treatment Unit [ X ] Multi-chambered [ ] In series

Gallons / GPD capacity N/A [ ] Multi-chambered [ ] In series

Gallons Grease Interceptor capacity

Gallons Dosing Tank capacity gallons at doses per 24 hours doses per 24 hours

Drainfield 308 Square feet primary drainfield system

Square feet N/A system

System type [ X ] Standard [ ] Filled [ ] Mound [ ]

Configuration [ X ] Trench [ ] Bed [ ]

Location of benchmark/reference point Nail with metal cap and orange tape in utility pole near OSTDS

Elevation of proposed system site 24 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point

Bottom of drainfield to be 54 [ X ] inches [ ] feet [ ] above [ X ] below benchmark/reference point

Fill required 0 inches Excavation required inches

Other Abandon noncertified tank in accordance with 62-6. Install a new 900-gallon septic tank system with 308 sq ft drainfield. Maintain 75 feet setback to private well. Maintain 75 feet setback to surface water. Maintain all setbacks in accordance with FAC 62-6. If the benchmark is removed a re-inspection fee will be charged to reset the benchmark. The above must be completed prior to Final Inspection & Approval. A re-inspection fee will be charged for additional inspections. The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 200 gpd.

Specifications by Charles F Oker Private Site Evaluator Printed Name Title Signature

Approved by Nickolas Hoyt Environmental Specialist II FDEP-DWRM

Printed Name Title Office Signature

Date issued 06/18/2026 Expiration date 12/18/2027

DEP 4016 07/2025, Construction Permit and Inspection, Part 1 of 2 (Obsoletes all previous editions which may not be used) Incorporated: subsection 62-6.003(1), F.A.C. Page 1 of 3

Nickolas Hoyt Approved

File details come from the government source that posted it. Updated .