NAV SEA MAIN BLDG 10 REV 5 4.7.26_Redacted 1.pdf
PDF 128 KB Posted
- Solicitation number
- N0016726Q1113
About this file
This document is a set of architectural floor plans and furniture layout designs for the NAV SEA Main Building, Revision 5, dated 3.31.26. The plans depict office spaces (specifically Offices 105 and 106) and an open workspace area with detailed specifications for furniture, fixtures, and equipment placement.
The floor plans show comprehensive office configurations including workstations, storage cabinets, filing systems, power distribution elements, and specialized office equipment. Key furniture and component codes referenced throughout include workstation models (WS-2436, WS-2448, WS-2460, WS-2484), lateral files and shelving (LAT-36, LAT-42, SH-CTL-24), pedestals (PED-24), and various desk units (6624-F, 6630-F, 6636-F, 6648-F, 6660-F, 8224-F, 8230-F, 8236-F, 8248-F). The document also specifies electrical infrastructure including power poles, V-Channel components, cable management systems (CABL-28), and data port elements (E-DP6B). Dimensions are provided for spatial planning, including ceiling heights noted at 9 feet, and specific measurements for individual workstations and office areas. The plans indicate some areas marked as "EXISTING" and "THIS AREA ALREADY ORDERED - DO NOT DO," with sections designated as "add to order NEW," suggesting this is an update to a previously established office configuration.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
' 6
10' 1" 9' 0"
WS-2448
W S-2448
PED
-24
LAT-36
3248-F
WS-2436/4824 7'
C T-
3248-F
LH BIF
1' 3" 8' 9"
R
EC
EP
TI
O N
-F
-F
4224-F
2W90
EOR
SH-CTL-24
2W90
L3L2
E-DP6B
EOR
RH-CTL-30
V-Channel-48W
C
TBK
/P air
C
TB
K /P ai r
C
TB
K /P ai r
C
TBK
/P air
6660-F 6624-F
WS-2436 W
S-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
6660-F 6660-F
WS-2436 WS-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
6660-F 6660-F
WS-2436 WS-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
6660-F 6660-F
WS-2436 WS-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
6660-F 6660-F
WS-2436 WS-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
6660-F 6660-F
WS-2448/6024
W S-2460
PED-24
LA
T-42
8236-F 8248-F
L2L3
SH
-C
TL
-2
SH-CTL-24
SC
PDP PDP
6660-F 6660-F
WS-2436
57"J57"J57"J57"J
EOR
6624-F
NOTE 9' ceilings 8224-F8230-F
-F
-F
L2 L3
L2
L3
L2 L3
L2 L3
6636-F pr in te r pr in te r m achine
L3 L3
L1 L1
W S-2484
CA
BL-28
CA
BL-28
3'
5' 0"
8230-F
V-Channel-48W
V-Channel-48W
V-Channel-48W
V-Channel-48W
V-Channel-48W
V-Channel-48W
2W90
2W90
EOR
AL-24/DV/R
LH-CTL-24
S C
PF
PF
PF
PF
PF
CIFCIF
55"J
POWER BREAK
6624-F 6624-F 6624-F 6624-F 6624-F
2W90 2W90
2W
EOR EOR EOR EOR
2W
2W90
EOR
6624-F
2W
M H
S/60/L
M H
S/60/L
M H
S/60/L
M H
S/60/L
M H
S/60/L
M H
S/60/L
PDRAWER
PDRAWER
PDRAWER
PDRAWER
PDRAWER
PDRAWER
storage cabinets
6624-F
EOR
6624-F
EOR
6624-F
EOR
6624-F
EOR
6624-F
EOR
3' 0"
4D 4D
4D
Power pole power pole
' 3
' 9
7' 2" 8' 6" 6" 6"
' 2
6636-F
-F
6624-F
-F
-F
WS-243
W S-
WS-2460
P
ED
-2
LAT-36
SH
-C
TL
-2
SH-CTL-24
SC
2 W90
EOR
MHS/36/L
6636-F
-F
6624-F
-F
6648-F
-F
WS-24
W S-2436
WS-2460
P
ED
-2
LAT-36
SH
-C
TL
-2
SH-CTL-24
SC
2W90
EOR
MHS/36/L
6636-F
-F
6624-F
-F
6648-F
-F
WS-24
W S-2436
WS-2460
P
ED
-2
LAT-36
SH
-C
TL
-2
SH-CTL-24
SC
2W90
EOR
MHS/36/L
6636-F
-F
6624-F
-F
6648-F
-F
WS-24
W S-2436
WS-2460
P
ED
-2
LAT-36
SH
-C
TL
-2
SH-CTL-24
SC
2W90
EOR
MHS/36/L
-F
-F
9'
6648-F
EO
R
4260-F
6636-F
4260-F
6636-F
6630-F
6636-F
W S-
WS-2460
P
ED
-24
LAT-36
SH
-CTL-24
SH-CTL-24
EOR
M
HS/36/L
W S-2436/6024
4260-F 4260-F
6648-F
SC
EOR
M H
S/
/L
4260-F
6636-F
4260-F
6636-F
6648-F
WS-2460
LAT-36
SH
-CTL-24
SH-CTL-24
EOR
W S-2436/6024
WS-24
/36
4236-F
WS-2460
LAT-36
4260-F
6648-F
EOR
-F
6648-F
2W90
EOR
W S-
' 1
12' 4" 13' 11"
W S-24
WS-2
W S-
W S-
-F
-F
6636-F
-F
-F
5060-F
L2 L2
L3 L3
SH-CTL-24
SH-CTL-24
SH
-C
TL-24
SH
-C
TL-24
WS-2460
WS-2460
P
ED
-2
P
ED
-2
LAT-36
-F
-F
WS-243
WS-2442
5836-F
-F
5842-F
-F
L2 L3
SH
-C
TL
-2
SH-CTL-24
W S-
PED-24
LA
T-
MHS/42/L
4224-F
W S-2436
WS-2442
5836-F
-F
5842-F
SH
-C
TL
-2
SH-CTL-24
LA
T-30
MHS/42/L
5824-F
5836-F5836-F
L2 L3
SH
-C
TL
-2
WS-2466
LAT-36
4224-F
W S-2442
5842-F
PED-24
-F
Office 105 Office 106
THIS AREA ALREADY ORDERED - DO NOT DO
6630-F
2W90
EOR
903W
3W
3W
3W
3W
3W
3W
SC
EOR
3W
EOR
SC
SH
-C
TL-24
L1 L2 L1 L2 L3 L4
RH BIF
E-DP6B E-DP6B E-DP6B E-DP6B
E-DP6B E-DP6B E-DP6B E-DP6B
E-
DP
6B
L1 L1
L1 L2
L2 L2L3 L3L4 L4
55"J
EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING
EO
R
EO
R
EO
R
EO
R
3W
903W
LH
BIF
S C
S C
E-
DP
6B E-
DP
6B
E-DP6B E-DP6B
E-DP6B
EOR
EO
R
EOR
EO
R
2 W90
2W
2W90
2W90
2W
3W
3W
S C S
C
LH-CTL-24
L1 L4
63"J
55"J
R H
BI
F
Added new wing panel
R
H BIF
RH-CTL-24
LH-CTL-24
V- Ch an ne l-4 8W
6636-F 6636-F 6636-F 6636-F
3'
3' 0"
2'
0"
2' 11" PDRAWER
PDRAWER
PDRAWER
PDRAWER
WS-246
0/362
WS-2460
LAT-36
W S-2460
P
ED
-2
SH-CTL-24
SH
-C
TL-24
L3 L4
6630-F 6630-F
EOR 3' 3" EOR
4224-F MHS/36/L
add to order NEW
2' 6"
PDRAWER
PDRAWER
PDRAWER
PDRAWER
LAT-36
MHS/36/L
WS-2454/3624
2'
-F
-F
PDRAWER PDRAWER
PDRAWER
1 2
9'
PDRAWER
PDRAWER
1' 6" 2' 8"
5830-F
4'
8' 5"
-F
6636-F
W S-
P
ED
-24
SH-CTL-24
M H
S/36/L
M H
S/
/L
W S-2460
PE
D
-2
-F
3' 3"
NAV SEA MAIN BUILDING REV 5
3.31.26
33"J 33"J 33"J
2W90
3W
PTPBPTPB
81"J
3W
6648-F 6642-F
6642-F
SC
LH-CTL-24
RH-CTL-24RH-CTL-24
LH-CTL-24
LH
-C
TL-24
PTPBPTPB
File details come from the government source that posted it. Updated .