Attachment E - FRC-SW Abrasive Waterjet Machine Location Plan.pdf

PDF 121 KB Posted

Attached to
Waterjet Cutting Machines
Solicitation number
N6893621Q0116
Issued by

About this file

This document contains a federal solicitation and related opportunity file. The Naval Air Warfare Center Weapons Division is soliciting proposals for the procurement of two new abrasive waterjet cutting machine centers with computer numerical control. The machines must be new equipment and will support Fleet Readiness Center Southwest and Fleet Readiness Center East. The NAICS code for this requirement is 333517 and the size standard is 500 employees. Responses are due no later than July 20, 2021. Offerors can submit questions by email to the point of contact by July 12. This is a 100% small business set-aside solicitation conducted under simplified acquisition procedures. Interested parties must ensure their SAM registration is active.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 472

PROPOSED PARTIAL PLAN VIEW

PROJECT AREA

IND. PLANNING/

DESIGN OFFICE

AutoCAD SHX Text

480V,3PH,BUSS

AutoCAD SHX Text

480V,3PH,BUSS

AutoCAD SHX Text

BENCH

AutoCAD SHX Text

HYDRAULIC PRESS

AutoCAD SHX Text

CART

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

CART

AutoCAD SHX Text

CRANE 4000LBS

AutoCAD SHX Text

WATER-JET PEMA: TBDTBD

AutoCAD SHX Text

CONTROLLER TOWER

AutoCAD SHX Text

SOLIDS REMOVER

AutoCAD SHX Text

SAND SILO

AutoCAD SHX Text

FLOOR DRAIN

AutoCAD SHX Text

LOCKERS

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

VID

AutoCAD SHX Text

LOADING ZONE

AutoCAD SHX Text

480V,3PH,BUSS

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text W

AutoCAD SHX Text

NO. 2

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text P

AutoCAD SHX Text Q

AutoCAD SHX Text R

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

AutoCAD SHX Text

EXPANSION JOINT

michael.a.anderson9 Text Box

NOTE:

Overhead clearance:

23'-1"

Building roll-up door clearance:

22'H x 13'-6"W

Electrical service:

20' from proposed location

Sheets and Views
L-02

File details come from the government source that posted it. Updated .