Attachment E - FRC-SW Abrasive Waterjet Machine Location Plan.pdf
PDF 121 KB Posted
- Attached to
- Waterjet Cutting Machines Federal contract opportunity
- Solicitation number
- N6893621Q0116
About this file
This document contains a federal solicitation and related opportunity file. The Naval Air Warfare Center Weapons Division is soliciting proposals for the procurement of two new abrasive waterjet cutting machine centers with computer numerical control. The machines must be new equipment and will support Fleet Readiness Center Southwest and Fleet Readiness Center East. The NAICS code for this requirement is 333517 and the size standard is 500 employees. Responses are due no later than July 20, 2021. Offerors can submit questions by email to the point of contact by July 12. This is a 100% small business set-aside solicitation conducted under simplified acquisition procedures. Interested parties must ensure their SAM registration is active.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFQ N6893621Q0116-0002.pdf | ||
| Updated Attachments 21Q0116.zip | ZIP file | |
| 21Q0116 Solicitation Amendment.pdf | ||
| RFQ Attachment E FRC-SW Abrasive Waterjet Machine Location Plan.pdf | ||
| 21Q0116 Attachments.zip | ZIP file | |
| RFQ N6893621Q0116.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 472
PROPOSED PARTIAL PLAN VIEW
PROJECT AREA
IND. PLANNING/
DESIGN OFFICE
AutoCAD SHX Text
480V,3PH,BUSS
AutoCAD SHX Text
480V,3PH,BUSS
AutoCAD SHX Text
BENCH
AutoCAD SHX Text
HYDRAULIC PRESS
AutoCAD SHX Text
CART
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
CART
AutoCAD SHX Text
CRANE 4000LBS
AutoCAD SHX Text
WATER-JET PEMA: TBDTBD
AutoCAD SHX Text
CONTROLLER TOWER
AutoCAD SHX Text
SOLIDS REMOVER
AutoCAD SHX Text
SAND SILO
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
VID
AutoCAD SHX Text
LOADING ZONE
AutoCAD SHX Text
480V,3PH,BUSS
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text W
AutoCAD SHX Text
NO. 2
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text Q
AutoCAD SHX Text R
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
EXPANSION JOINT
michael.a.anderson9 Text Box
NOTE:
Overhead clearance:
23'-1"
Building roll-up door clearance:
22'H x 13'-6"W
Electrical service:
20' from proposed location