N68335-16-T-0396_-_Air_Stair_Q A.docx
DOCX document 18 KB Posted
- Attached to
- CHASSIS-MOUNTED PASSENGER STAIR
- Solicitation number
- N68335-16-T-0396
About this file
Q A
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment_0001_-_Air_Stair_Minimum_Requirements_Rev3.xlsx | XLSX spreadsheet | |
| N68335-16-T-0396_-_Air_Stair_Q A.docx | DOCX document | |
| Attachment_0001_-_Air_Stair_Minimum_Requirements_Rev2.xlsx | XLSX spreadsheet | |
| N68335-16-T-0396_-_Air_Stair_Q A.docx | DOCX document | |
| Attachment_0001_-_Air_Stair_Minimum_Requirements_Rev1.xlsx | XLSX spreadsheet | |
| Attachment_0001_-_Air_Stair_Minimum_Requirements.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N68336-16-T-0396 – Chassis-Mounted Passenger System Question & Answer Round 1
1. The diesel engine indicated in number 4, is ULSD acceptable or does your customer require compatibility with JP-8 fuel?
A. The Government’s minimum requirement is for the chassis-mounted passenger system’s diesel engine to run on ULSD. See revised Attachment 0001, Minimum Requirements.
2. What size fire extinguisher in number 11?
A. The Government’s minimum requirement is for a fire extinguisher type B/C and size III. See revised Attachment 0001, Minimum Requirements.
3. Two hooks in the front only, correct? Number 12 A. The Government’s minimum requirement is two (2) two hooks on the front of the chassis-mounted passenger system. See revised Attachment 0001, Minimum Requirements.
4. Can you provide clarification on number 13, Fall Protection system?
A. Fall protection system is not required. The Government’s minimum requirement is to provide a chassis-mounted passenger system with sliding panels and handrails for passenger safety. See revised Attachment 0001, Minimum Requirements.
File details come from the government source that posted it. Updated .