N68336-16-T-0396 – Chassis-Mounted Passenger System Question & Answer Round 1

1. The diesel engine indicated in number 4, is ULSD acceptable or does your customer require compatibility with JP-8 fuel?

A. The Government’s minimum requirement is for the chassis-mounted passenger system’s diesel engine to run on ULSD. See revised Attachment 0001, Minimum Requirements.

2. What size fire extinguisher in number 11?

A. The Government’s minimum requirement is for a fire extinguisher type B/C and size III. See revised Attachment 0001, Minimum Requirements.

3. Two hooks in the front only, correct? Number 12 A. The Government’s minimum requirement is two (2) two hooks on the front of the chassis-mounted passenger system. See revised Attachment 0001, Minimum Requirements.

4. Can you provide clarification on number 13, Fall Protection system?

A. Fall protection system is not required. The Government’s minimum requirement is to provide a chassis-mounted passenger system with sliding panels and handrails for passenger safety. See revised Attachment 0001, Minimum Requirements.