This document is an amendment to a solicitation requesting quotations for a Direct Attached Storage (DAS) Storage Area Network (SAN) system. The Naval Surface Warfare Center Philadelphia Division seeks two SAN systems with specified components, including industrial rack mount servers, storage arrays, computer racks, power distribution units, and KVM switches. Responses are due by email to Kevin O'Shaughnessy by June 24, 2020 at 4:00 PM EST. The amendment revises the statement of work and attaches vendor questions and answers. Required server components include Intel Xeon processors, RAM, SSD boot drives, networking interfaces, and Windows Server 2016 software. Storage arrays must support a minimum 5.5PB raw capacity using 14TB SAS or SATA drives. The computer rack and power distribution units must meet dimensional and compatibility standards.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| DAS SAN_QA Responses 6.26.20.docx | DOCX document | |
| DAS SAN Request Response Extension Amendment 0001.pdf | ||
| N6449820R4059 NSWCPD DAS SAN.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
Solicitation N6449820R4059 is amended for the follow ing:
- Statement of Work item 0004 is revised (see page tw o)
- Vendor Q&A is Uploaded as an attachment
All other terms and conditions remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 26-Jun-2020
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6449820R4059
X 9B. DATED (SEE ITEM 11)
10-Jun-2020
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
26-Jun-2020
CODE
NAVAL SURFACE WARFARE CENTER PHILA
CODE 0223, KEVIN OSHAUGHNESSY
215-897-1962, KEVIN.OSHAUGHNESSY1@NAVY.MIL
5001 SOUTH BROAD STREET
PHILADELPHIA PA 19112
N64498 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N6449820R4059
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
SPECIFICATIONS
Item 0001 DAS (Direct Attached Storage) SAN (Storage Area Network) Redundant Storage
Controller Unit(s)
Industrial 2U, 19 inch rack mount computer system(s) that shall meet the following specifications:
1. Industrial 2U, 19 inch rack mount chassis.
2. Contain a 720 watt hot-swappable redundant internal power supply.
3. Chassis can only be cooled from front and back. Top and bottom cannot contain cooling vents.
4. Operate in the temperature range of 32 DEGF to 104 DEGF.
5. Include dual Intel Xeon Silver 4210 Processor with 13.75MB cache and 2.20GHz, or equivalent.
6. Include 256GB, DDR4 ECC RAM.
7. Contain two Ethernet controllers of at least 10Gbps, either integrated on the motherboard or as a separate PCIe expansion card.
8. Include two (2) 512 GB Enterprise rated SSD or NVMe mirrored (RAID 1) configured as the boot drive.
9. Include Windows Server 2016 Datacenter Edition, 64 bit, with 20-core license
a. Servers in each unit will be configured in cluster mode
10. All hardware must be Microsoft Windows 2016 Datacenter Edition compatible.
11. Hard drives are to be installed in a slide-out chassis easily accessible from the front of the computer.
12. All required system driver software must be included on a CD/DVD containing current drivers for Microsoft Windows 2016 Datacenter Edition.
13. Include an 8X DVD/CD ROM drive that color matches the chassis.
14. Include one USB port accessible from the front of the chassis.
15. Video output, onboard or via installed video adaptor card, that supports 1280x1024 resolution.
16. Trusted Platform Module (TPM) v. 2.0 must .be installed.
17. Include all necessary slide rail hardware for mounting in a 19 inch rack 48” deep with square hole configuration.
18. Include dual RAID controller/engine, either integrated or as an external component
a. Controllers are to be redundant and support active-active configuration and high-availability.
b. Support 12GB/s.
c. Have 1Gb cache.
d. Include Zero Maintenance Flash Cache protection.
e. Include Battery Backup Unit.
f. Support RAIDs 0,1,10,3,5,6,20,50,60,single-disk,or JBOD mode.
g. RAID subsystem via external RAID engine is acceptable.
19. Include power cables compatible with ITEM 0004.
Item 0002 DAS SAN Storage Arrays
Industrial 4U, 19 inch rack mount Storage Arrays that shall meet the following specifications:
1. Must be compatible with ITEM 0001.
2. Cannot exceed 6 JBODs and have a total raw storage capacity of not less than 5.5PB.
3. Industrial 4U, 19 inch rack mount chassis.
4. Dual hot-swappable 1400 watt redundant power supplies.
5. Include hot swappable cooling fans.
6. Chassis only be cooled from front and back. Top and bottom cooling vents are not acceptable.
7. Operate in the temperature range of 32 DEGF to 104 DEGF.
8. Include swappable dual-controllers/IO modules to support high-availability.
9. Contain 4 6Gb/s SAS/mini-SAS ports per unit.
10. Support standard RAID levels (0,1,5,6,10,50,60).
11. Include 4 mini-SAS HD ports per module.
12. Installed drives must be Enterprise Class SAS or SATA drives with following specifications:
a. Storage: 14TB
b. Speed: 12Gb/s
c. RPM: 7200
13. Include power cables compatible with ITEM 0004.
Continued on next page…
Item 0003 Computer Rack to contain ITEMS 0001, 0002, 0004, and 0005
Server Grade Standard U Equipment Mounting Rack that shall meet the following specifications:
1. Rack dimensionally and color match APC NetShelter SX 42U AR3300.
2. Rack outer dimensions not to exceed 80”x24”x48” (H x W x D).
3. Rack includes removable side panels on both right and left sides.
4. Rack includes REMOVABLE front AND rear hinged door panels.
a. Panels are vented.
b. Front panel are lockable.
5. Rack has a usable inside height of 42U.
6. Rack has a usable inside depth of at least 40”.
7. Rack has a usable inside width of 19” for rack-mount hardware.
8. Rack will be black to color match existing equipment.
9. Rack has 2 front and 2 rear vertical rails.
a. Vertical rails are to be adjustable, in both the front and back directions.
b. Vertical rails will have SQUARE holes for quick-connect computer rails (see Figure
2).
Figure 2 – Rail Mounting Holes
Item 0004 DAS Room Rack Power Distribution Unit (PDU)
Rack PDUs shall have the following specifications:
1. PDU is be internally rack mountable and compatible with Item 0003.
2. Input Power to the PDU must be provided through a NEMA L6-30P Plug. Length of cord must minimally be 10 ft (120 in).
3. Output power receptacles must be compatible with Items 0001, 0002, and 0005.
4. Meet cUL Listed, CSA C22.2 No. 60950-1-03, UL 60950-1, UL Listed
Continued on next page…
Item 0005 DAS Room Rack Mount KVMs
Standard 17” screen rackmount KVM that shall meet the following specifications:
1. Have resolution of 1280x1024.
2. A minimum of 8 different computers can be supported.
3. Include 8 6ft USB cable kits that support screen, keyboard, and mouse functionality.
4. Include power cables compatible with ITEM 0004.
Item 0006 DAS SAN Spare HDDs
Identical HDDs used in Item 0002