AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

See description of Amendment on page tw o.

1. CONTRACT ID CODE PAGE OF PAGES

1 5

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 28-Sep-2019

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X N6449819Q0055

X 9B. DATED (SEE ITEM 11)

22-Aug-2019

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

28-Sep-2019

CODE

NAVAL SURFACE WARFARE CENTER PHILA

CODE 0223, DAVID RHOADS

215-897-7702, DAVID.RHOADS@NAVY.MIL

5001 SOUTH BROAD STREET

PHILADELPHIA PA 19112

N64498 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

david.rhoads@navy.milEMAIL:215-897-7702TEL:

DAVID A RHOADS / CONTRACTING OFFICER

N6449819Q0055

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

The following items are applicable to this modification:

SUMMARY OF CHANGES

SECTION SF 30 - BLOCK 14 CONTINUATION PAGE

The following have been added by full text:

Amendment 0003 has been issued to provide revisions to the Statement of Work (SOW) and to extend the Request for Quote (RFQ) response date. The requirements for the Exterior Doors to meet Unified Facilities Criteria (UFC) 4-010-01, DoD Minimum Antiterrorism Standards For Buildings have been removed from this project.

The following revisions are hereby incorporated into the SOW:

Remove:

1.25.13 International Building Code (IBC), except as modified by Unified Facilities Criteria (UFC) 1-

200-01, General Building Requirements, and Unified Facilities Criteria (UFC) 4-010-01, DoD Minimum Antiterrorism Standards For Buildings, latest revisions.

Replace with:

1.25.13 International Building Code (IBC), except as modified by Unified Facilities Criteria (UFC) 1-

200-01, General Building Requirements.

2.2.1 Metal Framing Components - G: Submit framing components to show sizes, thicknesses, layout, material designations, methods of installation, and accessories. Framing components must comply with ASTM C754 and C955 and the following subsections, and doors, hardware, and components must comply with ASTM F 2247 with ASTM F 2927 (Reference 1.25.8). See submittal requirements below. Structural and finished carpentry work shall be executed by qualified personnel having been regularly engaged in carpentry work of the type, size, and complexity similar to the work of this Contract for at least three years.

2.2.1.1 Doors and Frames - G: Submit manufacturer's descriptive literature for doors, frames, and accessories. Include data and details on door construction, panel (internal) reinforcement, insulation, and door edge construction. Products used shall meet the requirements of SDI/DOOR A250.8, except as specified otherwise. Prepare doors to receive door hardware as necessary. Form frames to sizes and shapes indicated, with knock-down field-assembled corners. Provide steel frames for doors, unless otherwise indicated. NOTE: Ensure all door jambs and headers are properly reinforced in accordance with SDI/DOOR A250.11 for structural rigidity and proper door operation. Provide additional framing elements (for example, metal studs) to maintain and preserve door-opening rigidity and alignment. All surfaces of doors and frames must be thoroughly cleaned, chemically treated, and factory primed with a rust inhibiting coating as specified in SDI/DOOR A250.8. Finished exterior door assemblies must meet the requirements of ASTM F 2247 with ASTM F 2927 (Reference 1.25.8), as described in UFC 4-010-01 (Reference 1.25.13).

2.2.1.2 Frame, Door and Hardware Installation - G: Submit manufacturer's descriptive literature for all hardware (door closers, locks, panic bars, etc). Include data and details on hardware installation and door construction. Products used shall meet the requirements of SDI/DOOR A250.8, except as specified otherwise. Set frames in accordance with SDI/DOOR A250.11. Hang doors in accordance with clearances specified in SDI/DOOR A250.8. Finished doors and frames must be strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Molded members must be clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Install all door hardware as necessary. Finished exterior door assemblies must meet the requirements of ASTM F 2247 with ASTM F 2927 (Reference 1.25.8), as described in UFC 4-010-01 (Reference 1.25.13).

2.2.1 Metal Framing Components - G: Submit framing components to show sizes, thicknesses, layout, material designations, methods of installation, and accessories. Framing components must comply with ASTM C754 and C955 and the following subsections. Structural and finished carpentry work shall be executed by qualified personnel having been regularly engaged in carpentry work of the type, size, and complexity similar to the work of this Contract for at least three years.

2.2.1.1 Doors and Frames - G: Submit manufacturer's descriptive literature for doors, frames, and accessories. Include data and details on door construction, panel (internal) reinforcement, insulation, and door edge construction. Products used shall meet the requirements of SDI/DOOR A250.8, except as specified otherwise. Prepare doors to receive door hardware as necessary. Form frames to sizes and shapes indicated, with knock-down field-assembled corners. Provide steel frames for doors, unless otherwise indicated. NOTE: Ensure all door jambs and headers are properly reinforced in accordance with SDI/DOOR A250.11 for structural rigidity and proper door operation. Provide additional framing elements (for example, metal studs) to maintain and preserve door-opening rigidity and alignment. All surfaces of doors and frames must be thoroughly cleaned, chemically treated, and factory primed with a rust inhibiting coating as specified in SDI/DOOR A250.8.

2.2.1.2 Frame, Door and Hardware Installation - G: Submit manufacturer's descriptive literature for all hardware (door closers, locks, panic bars, etc). Include data and details on hardware installation and door construction. Products used shall meet the requirements of SDI/DOOR A250.8, except as specified otherwise. Set frames in accordance with SDI/DOOR A250.11. Hang doors in accordance with clearances specified in SDI/DOOR A250.8. Finished doors and frames must be strong and rigid, neat in appearance, and free from defects, waves, scratches, cuts, dents, ridges, holes, warp, and buckle. Molded members must be clean cut, straight, and true, with joints coped or mitered, well formed, and in true alignment. Install all door hardware as necessary.

2.3.1.1 Exterior Doors: Replace the exterior doors of both entrances (6 each, 3 per entrance: door numbers (nos.) NW1, NW2, NW3, SW1, SW2, and SW3) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.) at the entrance. Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions; and, (c) with hardware of same duty rating and type. The new doors shall be ADA compliant. Read Section 2.2.1 for related material requirements.

2.3.1.1 Exterior Doors: Replace the exterior doors of both entrances (6 each, 3 per entrance: door numbers (nos.) NW1, NW2, NW3, SW1, SW2, and SW3) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.) at the entrance. Replace these doors with a similar style of store front doors as the existing doors, (a) to fit same rough opening;

(b) with doors that have tinted laminated glass panels of same dimensions; (c) painted to match existing conditions; and, (d) with hardware of same duty rating and type. The new doors shall be ADA compliant. Read Section 2.2.1 for related material requirements.

2.3.1.5 First-Floor Interior Double Doors: Remove and replace the double doors that allow access to the main 1st floor area (8 each, 2 pairs per entrance: door nos. NW6, NW7, NW9, NW10, SW6, SW7, SW9, SW10) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.). Remove the existing center-post framing set up for the doors. Install new doors painted to match existing conditions without any center post. Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions; and, (c) with hardware of same duty rating and type. The new doors shall be ADA compliant. Provide transitions between the concrete and terrazzo floor finishes at the doorways’ thresholds acceptable to the NSWCPD TPOC.

2.3.1.6 Second-Floor Interior Double Doors: Remove and replace the double doors that allow access to the 2nd floor area (8 each, 2 pairs of double doors per stairway: door nos. NW12, NW13, NW14, NW15, SW12, SW13, SW14, SW15) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.). Remove the existing center post framing set up for the doors. Install new doors painted to match existing conditions without any center post. All new hardware shall match existing conditions. Replace these doors (a) to fit same rough opening;

(b) with doors that have tinted laminated glass panels of same dimensions; and, (c) with hardware of the same duty rating and type.

2.3.1.7 Interior Single Doors: Remove and replace all interior single doors (6 each, 3 per entrance: door nos. NW4, NW5, NW11, SW5, SW8, SW11), including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.) in the vestibule and exterior stairwell.

Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions; and, (c) with hardware of the same duty rating and type.

2.3.1.5 First-Floor Interior Double Doors: Remove and replace the double doors that allow access to the main 1st floor area (8 each, 2 pairs per entrance: door nos. NW6, NW7, NW9, NW10, SW6, SW7, SW9, SW10) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.). Remove the existing center-post framing set up for the doors. Install new doors to match existing conditions without any center post. Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions;

(c) painted to match existing conditions; and, (d) with hardware of same duty rating and type.

The new doors shall be ADA compliant. Provide transitions between the concrete and terrazzo floor finishes at the doorways’ thresholds acceptable to the NSWCPD TPOC.

2.3.1.6 Second-Floor Interior Double Doors: Remove and replace the double doors that allow access to the 2nd floor area (8 each, 2 pairs of double doors per stairway: door nos. NW12, NW13, NW14, NW15, SW12, SW13, SW14, SW15) including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.). Remove the existing center post framing set up for the doors. Install new doors to match existing conditions without any center post. All new hardware shall match existing conditions. Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions; (c) painted to match existing conditions; and, (d) with hardware of the same duty rating and type.

2.3.1.7 Interior Single Doors: Remove and replace all interior single doors (6 each, 3 per entrance: door nos. NW4, NW5, NW11, SW5, SW8, SW11), including all door bucks, frames and hardware (such as locksets, closer arms, automatic equipment, etc.) in the vestibule and exterior stairwell.

Replace these doors (a) to fit same rough opening; (b) with doors that have tinted laminated glass panels of same dimensions; (c) painted to match existing conditions; and, (d) with hardware of the same duty rating and type.

Questions pertaining to the Request for Quotation shall be emailed to David Rhoads, at david.rhoads@navy.mil, no later than 12:00 PM, 4 October 2019.

The Request for Quotation due date has been extended to on or before 12PM, 11 October 2019 and shall be emailed to david.rhoads@navy.mil.

All other terms and conditions remain unchanged.