This document is a Task Group Instruction (TGI) for cleaning, inspecting, repairing, and preserving CHT Tank No. 3 on the USS BLUE RIDGE (LCC-19), a naval vessel. The specific work involves comprehensive maintenance of the tank and associated components, including commercial blast cleaning, visual inspection, repair of deteriorated welds and plate defects, replacement of zinc anodes and pipe hangers, and surface preservation. The tank is located in multiple ship compartments, has a capacity of 11,772 gallons, and requires detailed procedures for structural integrity assessment and restoration.

The TGI provides extensive technical specifications for the work, including requirements for surface preparation, nondestructive testing, weld repairs, and coating applications. Key technical details include removing and installing 22 zinc anodes, repairing up to one linear foot of deteriorated welds, base metal weld buildup of 60 square inches, and replacement of 10 square feet of deteriorated plate. The work is scheduled to begin on 1/12/2026 and complete by 5/15/2027, with specific instructions for dealing with potential hazards like asbestos and lead, and requirements for fire zone boundary protection and non-flammable closures.

View the file

Other files

File Type Posted
N6264925RA0210004.pdf PDF
Exhibit (A) BLR_5C1_TYCOM1 CDRL_r.pdf PDF
TGI_3819P12341A01_c0v0.pdf PDF
TGI_3819P59302A01_c1v1.pdf PDF
TGI_3819P12357_T01_c0v0.pdf PDF
TGI_3819P14206A01_c0v2.pdf PDF
TGI_3819P12362A01_c0v0.pdf PDF
TGI_3819P14211A01_c0v0.pdf PDF
TGI_3819P12311A01_c0v0.pdf PDF
TGI_3819P12354A01_c2v2.pdf PDF
TGI_3819P14203_T04_c0v0.pdf PDF
TGI_3819P12310A01_c4v1.pdf PDF
TGI_3819P51404A01_c0v0.pdf PDF
TGI_3819P12357_A01_c0v0.pdf PDF
TGI_3819P12321A01_c1v1.pdf PDF
TGI_3819P12338A01_c0v0.pdf PDF
BLR_5C1_TYCOM1 CDRL.pdf PDF
TGI_3819P12337A01_c0v0.pdf PDF
TGI_3819P14215A01_c0v0.pdf PDF
TGI_3819P12304A01_c0v0.pdf PDF
TGI_3819P12355_A01_c1v0.pdf PDF
TGI_3819P12318A01_c2v3.pdf PDF
TGI_3819P14203_A01_c2v1.pdf PDF
TGI_3819P12388A01_c1v1.pdf PDF
TGI_3819P12393_A01_c0v0.pdf PDF
TGI_3819P12317A01_c0v0.pdf PDF
N6264925RA0210003.pdf PDF
TGI_3819P51405A01_c0v0.pdf PDF
TGI_3819P14210A01_c0v2.pdf PDF
TGI_3819P14206T03_c0v0.pdf PDF
TGI_3819P51402A01_c1v1.pdf PDF
TGI_3819P14214A01_c0v0.pdf PDF
TGI_3819P12336A01_c0v0.pdf PDF
TGI_3819P59302T01_c0v0.pdf PDF
TGI_3819P13506A01_c0v0.pdf PDF
TGI_3819P12387A01_c0v1.pdf PDF
TGI_3819P12305A01_c0v0.pdf PDF
TGI_3819P14206T01_c0v0.pdf PDF
TGI_3819P14213A01_c0v0.pdf PDF
TGI_3819P12316A01_c5v3.pdf PDF
TGI_3819P12340A01_c1v0.pdf PDF
TGI_3819P12312A01_c0v0.pdf PDF
TGI_3819P14203_T01_c0v0.pdf PDF
TGI_3819P14203_T03_c0v0.pdf PDF
TGI_3819P51401A01_c1v2.pdf PDF
TGI_3819P14206T02_c0v0.pdf PDF
TGI_3819P12339A01_c3v2.pdf PDF
TGI_3819P12320A01_c0v0.pdf PDF
TGI_3819P16729A02_c0v1.pdf PDF
TGI_3819P12335A01_c1v0.pdf PDF
Show 40 more

Latest 50 of 127 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOUO

FOUO: Public availability to be determined under 5 USC 552

TASK GROUP INSTRUCTION

AIM REV 20.11.4.0 (OCTOBER 2020)

TGI COMPONENT NAME: TYPE: PHASE: REPEAT: CHANGE:

NO.: CHT TANK 8-98-1-W AY A 0 1

SHIP/HULL NO.: SHIP/HULL NAME: SYSTEM: PROJ/WO NO: CASREP CAT:

LCC-19 USS BLUE RIDGE 19P

CU PHASE TITLE:

F/O - CLEAN, INSPECT, REPAIR, AND PRESERVE CHT TANK NO. 3 (8-98-1-W)

PREPARING ACTIVITY:

PREPARED BY: CODE PHONE DATE

MASAHARU NAMEGAYA 231B. 315-243-4489 25-JAN-2024

APPROVED BY: CODE PHONE DATE

RYOUTA TAKAGI 231B. 315-243-4502 25-JAN-2024

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

CONCURRED BY: CODE PHONE DATE

REASON FOR WORK/NEED FOR CHANGE:

Additional procedure is required.

CHANGE INSTRUCTIONS:

CH1: Add Paragraph 5.1.1 (04/04/2024)

SPECIAL REQUIREMENTS:

This work affects a fire zone boundary. Fabrication and/or staging of a non-flammable closure is required.

SURFMEPP

CLEANLINESS FOR PIPING SYSTEM/EQUIPMENT LEVEL III

WORK CERTIFICATION SIGNATURES

COMPLETION OF WORK REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:

ACCEPTANCE OF COMPLETED WORK

PHYSICAL INSPECTION PHYSICAL INSPECTION COMPLETED: BADGE NO.: SHOP/CODE: PHONE: DATE:

REQUIRED:☐YES ☒NO

RECORDS REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:

TGI NO.: CHT TANK 8-98-1-W AY A 0

FOUO

SHIP: LCC-19 CHG/VER: 1/0

LIST OF EFFECTIVE PAGES

SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO.

1-6 J1-2 M1-2

1. SCOPE/PURPOSE

1.1 Title: CHT Tank No. 3 (8-98-1-W); clean, inspect, repair, and preserve

1.2 Location of Work:

1.2.1 CHT Tank No. 3 (8-98-1-W)

1.2.2 SD Storeroom No. One (7-98-1-A)

1.2.3 Engine Room (8-86-0-E)

1.2.4 Shaft Alley (9-98-0-Q)

1.2.5 Clean Salt Water Ballast (9-98-1-W)

1.2.6 Intel Storeroom (7-102-1-A)

1.2.7 Chemical Warfare Defense Equipment Storeroom (7-106-1-K)

1.3 Identification:

1.3.1 Quantity (One EA), CHT Tank No. 3

Tank No.: 8-98-1-W Capacity: 11,772 Gallons

1.3.2 Quantity (22 EA), Zinc Anode in 8-98-1-W

Type: ZHC-42 Size: 6 Inches x 12 Inches x 2-1/2 Inches Thickness

1.3.2.1 Quantity (44 EA), Securing Stud

Material: Steel Size: 1/2-13UNC x 1-1/4 Inches Thread Length

1.3.3 Quantity (5 AY), Pipe Hanger Assembly of Seawater Flushing Piping for CHT Tank located in 1.2.1 Remarks: See Sheet 3 of 2.11, 2.12 and Sketch Enclosure-01 for detail

1.3.3.1 Quantity (One AY), Pipe Hanger of Seawater Flushing Piping for CHT Tank located in 1.2.1 Size: 1/2 Inch IPS Material: Carbon Steel Specification: 810-4714432

JCN: ES01-NP9K

1.3.3.2 Quantity (4 AY), Pipe Hanger of Seawater Flushing Piping for CHT Tank located in 1.2.1 Size: 1-1/2 Inch IPS Material: Carbon Steel Specification: 810-4714432

JCN: ES01-NP9L

FOUO

SHIP: LCC-19 CHG/VER: 1/0

1.3.4 Quantity (One EA), Manhole Cover Plate (s) for 8-98-1-W Manhole No(s): 7-98-1 Size: 15 Inches x 23 Inches Material: Steel

1.3.5 Quantity (One EA), Bolting Ring for Manhole Cover Plate (s) for 8-98-1-W Manhole No(s): 7-98-1 Material: Steel

REF.

NO.

DOCUMENT

/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV CHG

NO.

COPY

REQ’D

(Y/N)

SOURCE

DOC

(Y/N)

PARA SEC PG CHP

1 NSI FY-25 NAVSEA Standard Items - ORG N 2 LI FY-25 Local Standard Items - ORG N

3 TM S9086-

CJ-STM-

010/CH-075

Fasteners 7 N

4 TM

SYSTEMS &

SPECIFICAT

IONS

SSPC Painting Manual Volume 2 - N

5 DWG 101-

2491014

FLOORS FR 99-120 D Y 3,4

,5, 6 DWG 103-

2491034

1ST & 2ND PLATF PLTG AFT

FR98

H Y AL

L

7 DWG 114-

2491158

TRANSV BHD FR 98 &109 K Y AL

L

8 DWG 114-

2491163

SHAFT ALLEY BHD F Y AL

L

9 DWG 123-

4354697

CHT #1, 2, 3 & 4 FR 48 - 52 P/S &

FR 98 - 102 P/S

E Y AL

L

10 DWG 114-

5341771

MOD CHT TANKS - CHT UPDATE A Y AL

L

11 DWG 528-

4347205

Salt Water Flushing Incidental to CHT System

A Y AL

L

12 DWG 810-

4714432

STD Pipe Hangers Fabrication

DETS & INSTL

L N

1.3.6 Quantity (2,550 SF), Entire Interior Surface of 8-98-1-W Remarks: The area includes tank side of manhole cover plate(s) and bolting ring(s).

1.4 Security Classification: None.

1.5 Initial Condition:

1.5.1 Critical Coated Area: CCNY-LCC19-004-25 for area listed in 1.3.6.

1.5.2 Potential Asbestos Hazard

1.5.3 Potential Lead Hazard.

1.5.4 Dry Dock Work

1.6 Contractor work start date: 1/12/2026

1.7 Contractor work completion date: 5/15/2027

2. REFERENCES:

FOUO

SHIP: LCC-19 CHG/VER: 1/0

REF.

NO.

DOCUMENT

/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV CHG

NO.

COPY

REQ’D

(Y/N)

SOURCE

DOC

(Y/N)

PARA SEC PG CHP

13 TM T-9630-

AB-MMD-

Corrosion Control Assessment and Maintenance Manual (CCAMM)

3 N

14 TM NAVSEA

4790/14

Tank and Void Structural and Coating Condition Survey (MRC G1N5)

- N

3. APPENDICES:

3.1 Appendix “J” TGI Job Summary Information Sheet

3.2 Appendix "M" TGI Material List

3.3 Appendix “D” Deficiency Form

4. GENERAL REQUIREMENTS:

4.1 Not Applicable.

5. PROCEDURE:

5.1 Accomplish the requirements of 099-902YO of 2.2 for each tank listed in 1.3.1.

5.1.1 Accomplish the requirements of 009-09 of 2.1 for the certification process.

5.1.2 Accomplish installation of each manhole cover for each tank listed in 1.3.1 in accordance with Figure 075-4-1 of 2.3.

5.1.2.1 Install new CRES washers conforming to FF-W-92, Type A, Grade One, Class B, and new brass nuts conforming to MIL-DTL-1222, Type One, Grade 464.

5.2 Commercial blast clean each tank listed in 1.3.1. Accomplish the requirements of surface preparation SSPC-SP- 6 of 2.4.

5.3 Accomplish a visual inspection of each tank listed in 1.3.1 for existing preservation coating, structural integrity, deterioration, pitting, each crack, and area of damage or distortion, including each sounding tube, tank vent, overflow, piping, structural member, and manhole cover, using 2.5 through 2.10 for guidance.

5.3.1 Submit one legible copy, in hard copy or approved transferrable media, of a report listing results of the requirements of 5.3 to the SUPERVISOR.

5.4 Repair each tank listed in 1.3.1, based on the report in 5.3.1 and CCIMS assessment report as designated by the SUPERVISOR, using 2.5 through 2.10 for guidance. See 5.11.5 through 5.11.7.

5.4.1 Vee-out and weld a total of one linear foot of each deteriorated and damaged weld. Each area of repair must include deck, bulkhead, shell plating, and overhead.

5.4.2 Chip and grind each surface flush in way of each repair.

5.4.3 Base metal weld buildup a total of 60 square inches of each plate defect in the tank.

5.4.3.1 For bidding purposes the base metal weld buildup must be one quarter inch thick.

5.4.3.2 Surface must be ground to sound metal prior to base metal weld buildup.

FOUO

SHIP: LCC-19 CHG/VER: 1/0

5.4.3.3 Fill each local pit and groove with weld material prior to application of each principal build up layer.

5.4.3.4 Grind each surface of completed base metal weld buildup smooth if greater than 1/8 inch above plate surface.

5.4.4 Remove existing, fabricate, and install new a total of 10 square feet of deteriorated plate.

5.4.5 Remove existing, fabricate, and install new a total of 4 linear foot of defective stiffener.

5.4.6 Accomplish the requirements of 009-12 of 2.1, including Table 2, Column(s) A, Lines One through 7.

5.4.6.1 Accomplish nondestructive testing in accordance with Line 11.

5.4.7 Accomplish the requirements of 009-25 of 2.1 for an air hose, water hose, or vacuum box test of each new insert weld seam. Allowable leakage: None.

5.5 Remove existing and install new each zinc anode and stud listed in 1.3.2, using 2.5 through 2.10 for guidance.

5.5.1 Chip and grind each surface flush in way of each repair.

5.5.2 Accomplish the requirements of 009-12 of 2.1, including Table 2, Column(s) A, Lines One through 7.

5.6 Remove existing and install each new pipe hanger assembly listed in 1.3.3, using 2.11, 2.12 and Enclosure-01 for guidance.

5.6.1 Accomplish the requirements of 009-12 of 2.1, including Table 2, Column(s) A, Lines One through 7

5.7 Accomplish the requirements of 009-32 of 2.1, including Table 3, Line(s) 25, for storeroom side surface of each cover plate listed in 1.3.4.

5.8 Accomplish the requirements of 009-32 of 2.1 for storeroom side surface of each bolting ring listed in 1.3.5.

5.9 Accomplish the requirements of 009-32 of 2.1, including Table 4, Line(s) 16, for each area listed in 1.3.6.

5.9.1 Submit new coating data applied to the SUPERVISOR in accordance with 2.13 and 2.14.

5.10 Accomplish the requirements of 009-32 of 2.1 for each new and disturbed surface.

5.11 Notes:

5.11.1 Planner: Code 231B M. Namegaya, 243-4489

Planner: Code 234 R. Saeki, 243-1109

5.11.2 Work Integration Manager (WIM): Code 333 T. Yaginuma, 080-5419-0598

5.11.3 2.14 is available on P:\C200\C225\Enclosures\C231\Tank and Void Structural and Coating Condition Survey

(MRC G1N5).

5.11.4 This TGI meets the intent of DDG CSWT File No. 123-111, 123-133, and 123-142.

5.11.5 CCIMS assessment of each tank listed in 1.3.1 will be accomplished by SRF-JRMC (TGI No.

3819P12356I01), and the Project team will provide the assessment report with engineering evaluation under DL process for front loading structure repair.

FOUO

SHIP: LCC-19 CHG/VER: 1/0

5.11.6 Removal and installation of interferences, and gas free operation, preservation of boundary spaces relating to front loading structure repair are not included in this TGI. They will be covered by a DL in the future based on Contractor submitted condition report.

5.11.7 Materials for structure members relating to front loading repair will be provided in the future as a DL based on Contractor submitted condition report.

5.11.8 Work per this instruction involves cutting an access (or removal of a door) through a fire zone bulkhead, through the hull of the ship above the turn of the bilge, through ventilation components (ducting, plenums, etc.), or through any air-tight, fume-tight or watertight bulkheads normally used to control air flow in the event of a shipboard fire. A nonflammable closure is required in accordance with COMNAVSEASYSCOM MSG R 261400Z JUL 12. The closure, if not continuously in use, shall be staged near the access, readily visible and accessible, so that any emergency responder can install the closure to affect proper air flow onboard the ship.

5.11.9 SRF-JRMC Code 134 will provide laboratory analysis and test service for disinfectant solution used for CHT tank when requested by WIM, Code 333.

5.11.10 Opening, initial cleaning of closing of each tank listed in 1.2.5 will be covered by TGI No. 3819P12344A01

(KTR TGI).

5.11.11 JCNs ER01-ZAL6, ER01-ZAS4, ER01-ZAW1, ES01-NP9K, and ES01-NP9L are related to this TGI.

5.12 Government Furnished Material (GFM):

5.12.1 SRF-JRMC will provide GFM listed in Appendix “M”.

5.13 SRF-JRMC will provide following service work: (TGI No. 3819P12356S02).

5.13.1 [C740] Crane and crane rigging service.

5.13.2 [X99E] Utility service, electrical.

5.13.3 [X99M] Utility service, including water supply, steam supply, and low pressure air supply except onboard blasting work.

5.13.4 [C106.1] Safety inspection for SRF-JRMC employees.

5.13.5 [C106.2] Gas free inspection for SRF-JRMC employees.

5.13.6 [C133] QA inspection for (G) symbol(s) and review of coating application data.

5.13.7 [C135] QA inspection for (G) symbol(s).

5.13.8 [C250] Technical support.

FOUO

J-1

SHIP: LCC-19 CHG/VER: 1/0

APPENDIX "J"

TGI JOB SUMMARY INFORMATION SHEET

SYSTEM: PLANT NO.: COMPONENT NAME: TYPE: PHASE: REPEAT: CU PH

VERSION:

CASREP

CAT:

CHT TANK 8-98-1-W AY A 0 0

CU PHASE TITLE:

F/O - CLEAN, INSPECT, REPAIR, AND PRESERVE CHT TANK NO. 3 (8-98-1-W)

PRIMARY COMPONENT:

COMPONENT UNIT LIST (FOR ASSEMBLIES):

CHT 8-98-1-W TK ZINC ANODE 8-98-1-W ZI MANHOLE 7-98-1 HA

ATTACHMENT LIST:

1. ENCLOSURE-01 (3819P12356A01-Sketch.pdf) saved on 24-JAN-2024 0000.

ZONE MANAGER: ZONE: COMPARTMENT: LEVEL: FRAME: SIDE:

YAGINUMA ,TAKEHIDE

JO: KO: TOTAL MAN HRS: PLANNING ACCEPTANCE:

3819P12356 A01

TOTAL MAT’L COST TOTAL DURATION:

CU PHASE DESCRIPTION:

The purpose of this TGI is to clean, inspect, repair, and preserve CHT Tank No. 3 (8-98-1-W)

Location of Work:

CHT Tank No. 3 (8-98-1-W) SD Storeroom No. One (7-98-1-A) Engine Room (8-86-0-E) Shaft Alley (9-98-0-Q) Clean Salt Water Ballast (9-98-1-W) Intel Storeroom (7-102-1-A) Chemical Warfare Defense Equipment Storeroom (7-106-1-K)

TASK NAME

SHOP TSD/WC TS CREW# MHRS

HIGH RAD

HOURS

RC

GRID#

5.1 LBR HRs, QA HRs 22 KE PC

5.2 PNTR HRs, ELEC HRs, QA HRs 22 KE PC

5.3 SFTR HRs 22 KE PC

5.4 SFTR HRs, WELD HRs, QA HRs, CARP HRs 22 KE PC

5.5 SFTR HRs, WELD HRs, QA HRs, PNTR HRs 22 KE PC

5.6 PFTR HRs, WELD HRs, PNTR HRs, QA HRs 22 KE PC

5.7 PNTR HRs, QA HRs 22 KE PC

5.8 PNTR HRs, QA HRs 22 KE PC

5.9 PNTR HRs, QA HRs 22 KE PC

5.10 PNTR HRs, QA HRs 22 KE PC

Dewatering/Cleaning Work CFM for marine chemist, chemicals, gaskets, fasteners, tank watch cost, and misc.

22 MQ CS

FOUO

J-2

SHIP: LCC-19 CHG/VER: 1/0

TASK NAME

SHOP TSD/WC TS CREW# MHRS

HIGH RAD

HOURS

RC

GRID#

Structural Work CFM for fire watch and tank watch cost, MT inspection cost, lead sampling/analysis cost, air compressor rental cost and fuel oil cost for air hose test, and MISC such as electrode, gases, temporary closure and covering material, and other consumable.

22 MQ CS

Zinc Anode Replacement Work CFM for fire watch cost, tank watch cost, and MISC such as gases, electrode, covering material and other consumable.

22 MQ CS

Piping Work CFM for fire watch cost, tank watch cost, lead sample cost and MISC such as electrode, weld rod and paint.

22 MQ CS

Preservation Work CFM for all paints, thinner, grits, grits disposal cost, latex concrete, tank watch cost, air compressor, dryer, fuel oil, air conditioning, and MISC such as covering material and other consumable.

22 MQ CS

Process Funding Document 10 CT OM

FOUO

M-1

SHIP: LCC-19 CHG/VER: 1/0

APPENDIX “M”

TGI MATERIAL LIST

SYSTEM: PLANT NO.: COMPONENT NAME: TYPE: PHASE: REPEAT: CU PH

VERSION:

CASREP

CAT:

CHT TANK 8-98-1-W AY A 0 0

CU PHASE TITLE:

F/O - CLEAN, INSPECT, REPAIR, AND PRESERVE CHT TANK NO. 3 (8-98-1-W)

MATERIAL REFERENCES

REF

NO.

DOCUMENT/DRAWING

NUMBER

DOCUMENT/DRAWING TITLE REV

1 114-5341771 A

JOB ORDER: KEY OP:

3819P12356 A01

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

001 6 1 M ANODE,CORROSION PRE,

ORDERED FOR KTR

ORIG: C231B M.NAMEGAYA,

243-4489

9B 5342 004860957 NA 4 N 40255001 22/EA

002 M STUD,WEL, ORDERED FOR

KTR

ORIG: C231B M.NAMEGAYA,,

243-4489

9B 5307 012813886 NA 4 N 40255028 44/EA

003 M WASHER,L, ORDER FOR KTR

ORG: C231B M.NAMEGAYA,

243-4489

9B 5310 015492705 NA 4 N 40255029 44/EA

004 M NUT,SELF, ORDER FOR KTR

ORIG: C231B M.NAMEGAYA,

243-4489

9B 5310 005957421 NA 4 N 40255030 44/EA

401 M PIPE HANGER, PIPE HANGER,

1/2"IPS,

TYPE 4,

LINER: SYNTHETIC RUBBER,

1/4"THK,

FASTENER: CRES 316,

LEG: 12"

ORIG: C234 R.SAEKI 243-1109

ORDERED FOR KTR

9B 4730 LL9601567 NA 4 N 40367454 1/EA

NOTES:

FOUO

M-2

SHIP: LCC-19 CHG/VER: 1/0

MATERIAL LIST

ITEM

NO.

PC

NO.

REF

NO.

M

C DESCRIPTION

STOCK

NUMBER

GENERIC

MATL

TYPE LVL QA

HAZ

MAT

DOC

NO.

QTY

REQD/

UNIT

QTY

USED/

UNIT

402 M PIPE HANGER, PIPE HANGER,

1-1/2"IPS, TYPE 4,

LINER: SYNTHETIC RUBBER,

1/4"THK,

FASTENER: CRES 316,

LEG: 12"

MODIFY FASTENER FROM

STEEL TO CRES 316

ORIG: C234 R.SAEKI 243-1109

ORDERED FOR KTR

9B 4730 LL9601570 NA 4 N 40367455 4/EA

FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____

☐ NUCLEAR APPENDIX "D"

DEFICIENCY FORM

☐ NON-NUCLEAR

1. SHIP/HULL NO.: 2a. DL or DR No.

(Circle One)

2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:

LCC-19 CHT TANK 8-98-1-W AY A 0

4a. ICN: 4b. KEY OP: 5. LOC SPACE/LVL: FRAME: P/S/C: 6. CAUSED BY:

3819P12356 A01

7. DESCRIPTION:

8. ORIGINATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:

9. CORRECTIVE ACTION:

10. EVALUATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:

FOR NON-NUCLEAR USE ONLY

11. RFD/RFW REQ’D ☐ LAR REQ'D ☐

ILS MOD REQ’D ☐

SRD/PLAN REV REQ'D ☐

DWG NO.: _____________________ S/A NO.: ___________________

12. ISOLATION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.:

SATISFACTORY:

13. SUBSAFE OQE RECORD? SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

YES ☐ NO ☐

14. CORRECTIVE ACTION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

COMPLETE:

15. INSPECTION REQ’D? INSPECTION COMPLETE/SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

_________:YES ☐ NO ☐

16. RECORDS REVIEW SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.

COMPLETE (DR ONLY)

DL’s ISSUED

(DR ONLY)

FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____

☐ NUCLEAR Deficiency Form Continuation Sheet ☐ NON-NUCLEAR

1. SHIP/HULL NO.: 2a. DL or DR No.

(Circle One) 2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:

LCC-19 CHT TANK 8-98-1-W AY A 0

ENCLOSURE-013819P12356A01 Sheet 1 of 1

SKETCH