NAVFAC DWG 60025676.pdf
PDF 998 KB Posted
- Attached to
- Building 17 and 17A Renovation and Addition
- Solicitation number
- N6247020R6000
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Large Cabinet.jpg | JPG image | |
| Tabernacle.jpg | JPG image | |
| 08 62 00 Translucent Wall Panels.pdf | ||
| Organ (2).jpg | JPG image | |
| Grand Piano.jpg | JPG image | |
| Baptismal Font.jpg | JPG image | |
| Organ (1).jpg | JPG image | |
| Altar (2).jpg | JPG image | |
| Amnd 0006 20R6000 Final.pdf | ||
| Altar (1).jpg | JPG image | |
| Amnd 0005 20R6000 Final.pdf | ||
| Amnd 0004 20R6000 Final.pdf | ||
| Amnd 0003 20R6000 Final.pdf | ||
| Amnd 0002 20R6000 Final.pdf | ||
| NAVFAC DWG 60025678.pdf | ||
| Amend 0001 20R6000.pdf | ||
| N4008519B0095 Drawings_Part8.pdf | ||
| N4008519B0095 Drawings_Part3.pdf | ||
| N4008519B0095 Drawings_Part6.pdf | ||
| N4008519B0095 Specs.pdf | ||
| N4008519B0095 Drawings_Part7.pdf | ||
| 19-0095 Asbestos Survey 011020.pdf | ||
| N4008519B0095 Drawings_Part2.pdf | ||
| N4008519B0095 Drawings_Part5.pdf | ||
| RFP N62470-20-R-6000.pdf | ||
| N4008519B0095 Drawings_Part1.pdf | ||
| 19-0095 Lead Survey 011020.pdf | ||
| N4008519B0095 Drawings_Part4.pdf | ||
| N4008519B0095 Drawings_Part9.pdf | ||
| Master PPI Form Template.xls | XLS spreadsheet |
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
20 CF
E F G H
0.5
B.1 B.7BA C D
I J K L M N O P
WH-1
BABYSITTING
MECH./ ELEC.
TELECOM
OFFICE
OFFICE
CORRIDOR
WOMENS
FELLOWSHIP HALL
KITCHEN
PANTRY
WH-2
2" DOMESTIC CW. FOR CONTINUATION
REFER TO CIVIL UTILITY PLAN
WYE STRAINER
BV (1.0 GPM)
P-10
P-10
P-9
P-8
P-11
P-2 (TYP. OF 4)
P-1
P-2
P-4
P-4
P-3
P-5
P-5
P-5
P-5
P-6
P-7
P-1
VESTIBULE
JAN.
UNISEX
MENS
MECH.
VESTIBULE
UNISEX
ALTAR
STORAGE
CORRIDOR
CHAPEL
STORAGE
CONFESSIONAL
VESTIBULE
EXIST. CW, ETR
P-11
P-8
EXIST. SACRISTY
SINK
EXIST. SACRISTY
DRAIN TO GRADE
EXIST. WH, ETR
EXIST. WH, ETR
WH
AC
AC
AC
AC
APPROX. CHILLER
LOCATION
1" CW, BG
3" FD
W/TP
3" FD
W/TP
3" FD
W/TP
EXIST. 1" CW, ETR
FOR CONT., REFER TO
CIVIL UTILITY PLAN
AC
W2 P-601
W1 P-601
A P-501
D P-501
D P-501
D P-501
B P-501
C P-501
1" RPZ
WYE STRAINER
5 1" CW, BG
02/24/2020
The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563
252.636.8778 (PHONE)
252.636.8992 (FAX)
WALKER
GROUP
i n c o r p o r a t e d the
ARCHITECTURE
DISCLOSURE OF INFORMATION
CONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE
(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.
(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
NPLUMBING NEW WORK FLOOR PLAN - DOMESTIC WATER
SCALE: 1/8" = 1'-0"
1 MOUNT BACKFLOW PREVENTER 24" AFF AND MAINTAIN 24" AROUND FOR
MAINTENANCE. ROUTE BACKFLOW PREVENTER RELIEF DISCHARGE TO 4"
FLOOR DRAIN.
PROVIDE COMPLETE CONNECTIONS FROM EXISTING WATER PIPING
ROUGH-INS TO WATER CLOSET (P-11) & LAVATORY (P-8). MODIFY PIPING AS
REQUIRED.
PROVIDE ELECTRIC STORAGE TANK WATER HEATER. COORDINATE EXACT
LOCATION WITH ALL TRADES. MAKE ALL CONNECTIONS COMPLETE.
1" CW MAIN TO BUILDING 17 IS EXISTING TO REMAIN. PROVIDE 1/2"
CONNECTION AND ROUTE 1/2" CW PIPE AS INDICATED.
PROVIDE 1" MAKEUP WATER PIPING. ROUTE 1" CW PIPE FROM THE
MECHANICAL ROOM TO OUTDOOR CHILLER BELOW GRADE. PROVIDE
INSULATION FOR UNDERGROUND PIPING & HEAT TRACING FOR OUTDOOR
PIPING TO CHILLER. PROVIDE CORRUGATED ALUMINUM JACKET FOR
EXPOSED PIPING & CONNECT TO AIR SEPARATOR AT CHILLER LOCATION.
COORDINATE WITH ALL TRADES.
ROUTE 1" CW & 1/2" HW PIPING AS HIGH AS POSSIBLE. AVOID CONFLICTS
WITH ALL TRADES. COORDINATE THE ROUTING OF THESE PIPES WITH ALL
TRADES PRIOR TO COMMENCING WORK.
ROUTE 1" MAKEUP WATER PIPING TO BOILERS. ROUTE PIPIING AS HIGH AS
POSSIBLE. DROP PIPING DOWN AT LOCATION INDICATED.
PROVIDE 1" ISOLATION VALVE IN VERTICAL POSITION.
ROUTE 1" RPZ RELIEF DRAIN TO 3" FD IN MECHANICAL ROOM.
NOTES THIS SHEET
AMENDMENT 00011 05/08/20
AutoCAD SHX Text
T. HAHN
AutoCAD SHX Text
P. MCNALLY
AutoCAD SHX Text
P. MCNALLY
AutoCAD SHX Text A
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text V
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text W
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text
TIMOTHY N. HAHN
AutoCAD SHX Text Lic. No. 058039
AutoCAD SHX Text
SATISFACTORY TO: DATE
AutoCAD SHX Text
APPROVED: PWO OR OICC DATE
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
DR.
AutoCAD SHX Text
DES.
AutoCAD SHX Text
SYM
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
CODE IDENT. NO
AutoCAD SHX Text
SIZE
AutoCAD SHX Text F
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SCALE: NOTED
AutoCAD SHX Text
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
CONST. CONTR. NO.
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
DATE
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
CATHOLIC CHAPEL, BLDG 17 AND 17A MCB CL NC
AutoCAD SHX Text
19-0095 RENOVATION AND ADDITION TO THE
AutoCAD SHX Text
T.H. BURTON P.E.
AutoCAD SHX Text
B.WALKER
AutoCAD SHX Text
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 4'
AutoCAD SHX Text 16'
AutoCAD SHX Text 8'
AutoCAD SHX Text 60025676
AutoCAD SHX Text
AutoCAD SHX Text P-201
AutoCAD SHX Text
PLUMBING NEW WORK FLOOR PLAN - DOMESTIC WATER
File details come from the government source that posted it. Updated .