N4008519B0095 Drawings_Part9.pdf

PDF 6 MB Posted

Attached to
Building 17 and 17A Renovation and Addition
Solicitation number
N6247020R6000
Issued by

View the file

Other files

File Type Posted
Large Cabinet.jpg JPG image
Tabernacle.jpg JPG image
08 62 00 Translucent Wall Panels.pdf PDF
Organ (2).jpg JPG image
Grand Piano.jpg JPG image
Baptismal Font.jpg JPG image
Organ (1).jpg JPG image
Altar (2).jpg JPG image
Amnd 0006 20R6000 Final.pdf PDF
Altar (1).jpg JPG image
Amnd 0005 20R6000 Final.pdf PDF
Amnd 0004 20R6000 Final.pdf PDF
Amnd 0003 20R6000 Final.pdf PDF
Amnd 0002 20R6000 Final.pdf PDF
NAVFAC DWG 60025678.pdf PDF
NAVFAC DWG 60025676.pdf PDF
Amend 0001 20R6000.pdf PDF
N4008519B0095 Drawings_Part8.pdf PDF
N4008519B0095 Drawings_Part3.pdf PDF
N4008519B0095 Drawings_Part6.pdf PDF
N4008519B0095 Specs.pdf PDF
N4008519B0095 Drawings_Part7.pdf PDF
19-0095 Asbestos Survey 011020.pdf PDF
N4008519B0095 Drawings_Part2.pdf PDF
N4008519B0095 Drawings_Part5.pdf PDF
RFP N62470-20-R-6000.pdf PDF
N4008519B0095 Drawings_Part1.pdf PDF
19-0095 Lead Survey 011020.pdf PDF
N4008519B0095 Drawings_Part4.pdf PDF
Master PPI Form Template.xls XLS spreadsheet
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

FIRE ALARM AND MASS NOTIFICATION LEGEND

FIRE ALARM MANUAL PULL STATION, 48" AFF TO ACTUATING ARM, UON

FIRE ALARM/MNS AUDIO/VISUAL (SPEAKER/STROBE)

APPLIANCE, 80" AFF, OR 6" BELOW FINISHED CEILING,

WHICHEVER IS LOWER, UON. SUBSCRIPT INDICATES

MINIMUM CANDELA RATING OF STROBE.

SPRINKLER SYSTEM SUPERVISORY FLOW SWITCH CONNECTION

F

S

F

S

FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNTED

F

15 STROBE ONLY APPLIANCE, 80" AFF OR 6" BELOW FINISHED

CEILING WHICHEVER IS LOWER, UON. SUBSCRIPT INDICATES

MINIMUM CANDELA RATING OF STROBE.

H FIRE ALARM SYSTEM HEAT DETECTOR

REQ'D REQUIRED

PNL PANEL

NATIONAL ELECTRICAL CODENEC

GROUNDGND

EXIST EXISTING

EXISTING TO REMAINETR

CONDUIT C

UNLESS OTHERWISE NOTEDUON

FIRE ALARM/ MASS NOTIFICATION SYSTEM

AREA OF REFUGE ASSISTANCEARA

ABBREVIATIONS

ABOVE FINISHED GRADEAFG

ABOVE FINISHED FLOORAFF

FMCP

BELOW FINISHED GRADEBFG

FIRE ALARM/MASS NOTIFICATION

CONTROL PANEL

S

WP

FIRE ALARM AUDIO (SPEAKER) APPLIANCE, 80" AFG, WALL MOUNT,

SUBSCRIPT "WP" INDICATES WEATHER PROOF. PROVIDE COOPER

WHEELOCK SERIES STH-15S OR APPROVED EQUAL.

MASS NOTIFICATION SYSTEMMNS

FIRE ALARM CONTROL PANELFACP

GENERAL FIRE ALARM NOTESFIRE ALARM DEMOLITION NOTES

GENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND FIELD

INVESTIGATION PRIOR TO DEMOLITION. VISIT THE EXISTING BUILDING PRIOR TO BID IN

ORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND IN ORDER TO

AVOID CONFLICTS. THE CONTRACTOR MUST PROTECT AND PRESERVE ALL EXISTING

WORK NOT PART OF PROJECT.

DASHED ITEMS: ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE EXISTING AND

MUST BE REMOVED.

SOLID ITEMS: ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING TO REMAIN.

EXISTING CONDUIT: EXISTING CABLING MUST BE REPLACED. EXISTING CONDUITS THAT

WILL NOT BE REUSED MUST BE REMOVED WHERE THEY WILL BE EXPOSED UPON

COMPLETION OF NEW WORK. EXISTING CONDUIT TO REMAIN CONCEALED IN WALLS

MUST BE ABANDONED. EXISTING CONDUIT TO REMAIN BELOW FLOOR SLAB MUST BE

CUT OFF ONE INCH BELOW ROUGH FLOOR AND GROUTED FLUSH. REMOVE WIRING

FROM CONDUIT THAT IS ABANDONED.

REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS. REPAIR, AT NO

ADDITIONAL COST TO THE OWNER, ANY DAMAGE CAUSED TO EXISTING

CONSTRUCTION AND/OR EQUIPMENT TO REMAIN.

DEMOLISHED MATERIALS: MATERIALS REMOVED UNDER DEMOLITION, NOT TO BE

RELOCATED OR DESIGNATED TO BE TURNED OVER TO THE OWNER, WILL BECOME THE

PROPERTY OF THE CONTRACTOR AND MUST BE REMOVED COMPLETELY FROM THE

SITE.

SCHEDULE OUTAGES: SCHEDULED OUTAGES MUST BE COORDINATED THROUGH THE

GOVERNMENT CONSTRUCTION MANAGER OR CONTRACTING OFFICER.

NOTIFICATION: NOTIFY THE GOVERNMENT CONSTRUCTION MANAGER OR

CONTRACTING OFFICE PRIOR TO TURNING OFF CIRCUITS.

GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, WORK SHOWN ON FIRE

ALARM DRAWINGS IS NEW WORK TO INCLUDE THE FIRE ALARM/MASS NOTIFICATION

PANEL, DEVICES, AND APPLIANCES ON DRAWINGS FOR A COMPLETE AND

OPERATIONAL SYSTEM.

COORDINATION: THE CONTRACTOR MUST REVIEW CONTRACT DOCUMENTS

INCLUDING FIRE ALARM DRAWINGS AND SPECIFICATIONS. CONTRACTOR MUST

COORDINATE AND ADJUST ACCORDINGLY AS DIRECTED BY THE COTR.

AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF DRAWINGS TO BE KEPT ON SITE

AND MARK DAILY, THE DRAWINGS IN RED AS THE PROJECT PROGRESSES IN ORDER

TO KEEP AN ACCURATE RECORD OF ALL DEVIATIONS BETWEEN THE WORK SHOWN

ON THE DRAWINGS AND THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKED

DRAWINGS MUST REFLECT ANY AND ALL CHANGES AND REVISIONS TO THE

ORIGINAL DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER THE MARKED

DRAWINGS TO THE COTR AT PROJECT CLOSE-OUT. IN ADDITION, PROVIDE CONTACT

ID POINT DESCRIPTIONS FOR EACH DEVICE.

INSPECTIONS: ARRANGE NECESSARY INSPECTIONS. DELIVER REQUIRED

INSPECTION CERTIFICATES TO THE GOVERNMENT.

LABELING: ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND COUPLINGS, WHEN

PROVIDED, MUST BE FACTORY PAINTED RED IN UNFINISHED AREAS (E.G. ABOVE

CEILINGS, MECHANICAL ROOMS, ETC.). ALL CONDUIT, JUNCTION/BACKBOXES,

COVERS AND COUPLINGS, WHEN PROVIDED, ARE PERMITTED TO BE PAINTED TO

MATCH THE ROOM FINISHING IN FINISHED AREAS. THE INSIDE COVER OR THE

JUNCTION BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST HAVE

PAINTED RED BANDS 3/4" WIDE AT 20' INTERVALS ON BOTH SIDES OF ALL FLOOR,

WALL, AND CEILING PENTRATIONS. LABEL ALL JUNCTION BOXES WITH CIRCUIT

DESIGNATIONS OF THE CABLING INSIDE. PROVIDE LEGIBLE TYPED LABEL ON ALL

ADDRESSABLE DEVICES TO INDICATE ITS ADDRESS. FOR ANY DEVICE LOCATED

ABOVE ACCESSIBLE CEILING, ATTACH A LEGIBLE TYPED LABEL TO THE CEILING GRID

INDICATING THE DEVICE NOMENCLATURE AND ADDRESS.

WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF FIRE ALARM EQUIPMENT

WITH MECHANICAL DUCTWORK, PIPING ETC. AND ASSURE WORKING CLEARANCE

WILL BE MET. SUFFICIENT ACCESS AND WORKING SPACE MUST BE PROVIDED AND

MAINTAINED AROUND FIRE ALARM EQUIPMENT AS REQUIRED BY THE NATIONAL

ELECTRICAL CODE. CONTRACTOR MUST COORDINATE FINAL LOCATION OF

EQUIPMENT PROVIDED.

FIRE ALARM REMOTE ANNUNCIATOR PANELFAA

MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE FINISHED

FLOOR TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED.

FIRE STOPPING: FOR WALL OR FLOOR PENETRATIONS THROUGH FIRE-RATED

STRUCTURES PROVIDE FIRE-STOPPING TO SEAL THE PENETRATIONS AFTER THE

CONDUIT HAS BEEN INSTALLED. FIRE STOPPING FOR PENETRATIONS MUST BE UL

APPROVED PER THE PENETRATION MADE IN ORDER TO MAINTAIN FIRE-RATED

INTEGRITY OF THE STRUCTURE.

FIRE ALARM COORDINATION: THE ELECTRICAL CONTRACTOR MUST COORDINATE

WITH THE FIRE ALARM SYSTEM PROVIDER AND PROVIDE POWER CONNECTIONS TO

COMPONENTS WHETHER SHOWN OR NOT. MANUFACTURERS REQUIRE VARYING

QUANTITIES OF POWER CONNECTIONS FOR EQUIPMENT LIKE EXPANDER PANELS

AND POWER SUPPLIES. THESE DEVICES ARE DEPENDENT UPON THE SPECIFIC

MANUFACTURERS SYSTEM. THE FIRE ALARM SYSTEM SUPPLIER MUST NOTIFY THE

OTHER APPROPRIATE SUB-CONTRACTORS ABOUT THESE REQUIREMENTS AND

CONNECTION MUST BE PROVIDED AS PART OF THE PROJECT.

FIRE ALARM EQUIPMENT SURVIVAL: A SMOKE DETECTOR IS REQUIRED AT ALL

CONTROL PANEL LOCATIONS (I.E. FIRE ALARM PANEL, NOTIFICATION EXTENDER

PANELS, TRANSMITTERS, ETC.). CONTRACTOR MUST PROVIDE SYSTEM SMOKE

DETECTORS FOR ALL LOCATIONS OF FIRE ALARM PANELS, TO INCLUDE THOSE

SHOWN AND THOSE THAT ARE ADDED BY THE CONTRACTOR FOR THEIR SPECIFIC

DESIGN.

CONDUIT: ALL ADDED FIRE ALARM/MASS NOTIFICATION SYSTEM WIRING MUST BE

INSTALLED IN CONDUIT (EMT MINIMUM). EXISTING EMT MAY BE REUSED WHERE IT

SATISFIES REQUIREMENTS OF NFPA 70.

CONDUIT SEALS: PROVIDE CONDUIT SEAL IN ACCORDANCE WITH NFAP 70 300.7 TO

RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES.

CONDUCTORS: ALL CONDUCTORS MUST BE REPLACED WITH NEW.

INTELLIGIBILITY LEVEL: CONTRACTOR MUST VERIFY INTELLIGIBILITY LEVEL BY

MEASUREMENT AFTER INSTALLATION OF 0.7 CIS FOR NAVY AND MARINE CORP

PROJECTS. COMMERCIALLY AVAILABLE TEST INSTRUMENTATION MUST BE USED TO

MEASURE INTELLIGIBILITY AS SPECIFIED BY IEC 60849 AND IEC 60268-16. THE MEAN

VALUE OF AT LEAST THREE READINGS MUST BE USED TO COMPUTE THE

INTELLIGIBILITY SCORE AT EACH TEST LOCATION.

D A

C T

(2) CAT6 UTP TO TELEPHONE PATCH PANEL

FINAL TERMINATIONS BY GOVERNMENT

PATCH PANEL

NETWORK

TELEPHONE

TO

EXISTING EQUIPMENT

3/4" CONDUIT

W/ PULL STRING

EXISTING

EXTERNAL

ANTENNA

5'

M

AX

IM

UM

C

AB

LE

L

EN

GT

H

25' MAXIMUM

DEDICATED 120V, 20A CIRCUIT

FROM SAME SOURCE THAT

FEEDS FACP.

FIRE ALARM/MASS NOTIFICATION SYSTEM RISER DIAGRAM

S F S H

TO OTHER ADDRESSABLE

DEVICES

PRIMARY + BACKUP

(2) CAT6 UTP (BLUE)

WP

TO OTHER ADDRESSABLE

DEVICES

FAA

D

RT

TO AHU

SHUTDOWN

1. THE FACP IS AN EXISTING COMBINED FIRE ALARM AND

MASS NOTIFICATION SYSTEM IN THE CHAPEL BUILDING

17. PROVIDE NEW SUB-PANEL FACP IN BUILDING 17A AND

NETWORK BACK TO THE EXISTING FACP IN BULDING 17.

2. THE NETWORKED FIRE ALARM AND DETECTION SYSTEM

IS TO BE FULLY COMPLIANT WITH THE CURRENT

EDITIONS OF UFC 3-600-01, UFC 3-600-10N, UFC 4-021-01,

AND NFPA 72 FOR A FIRE ALARM AND AN EMERGENCY

VOICE ALARM COMMUNICATION SYSTEM. THE SYSTEM IS

DESIGNED TO INTERFACE WITH THE SITE MNS.

3. THE FACP MUST BE CAPABLE OF ACCEPTING 10 VOLTS

ROOT MEAN SQUARED (VRMS), 25 VRMS, 70.7 VRMS

AND/OR LINE LEVEL (.707 VRMS) AUDIO INPUTS.

4. FACP MUST BE CONFIGURED TO ACCEPT DRY CONTACT

INPUT FROM AN EXTERNAL INTERFACE TO ALERT THE

FIRE ALARM PANEL THAT A MNS MESSAGE IS

FORTHCOMING. THE FIRE ALARM PANEL MUST BE

CONFIGURED SO THAT WHILE THIS INPUT IS ACTIVE

(CONTACT CLOSED) THE FIRE ALARM PANEL MUST

ROUTE AUDIO PROVIDED BY THE MNS INTERFACE

DIRECTLY TO ALL CONNECTED FIRE ALARM SPEAKERS.

THE SYSTEM MUST BE PROGRAMMED SO THIS EXTERNAL

AUDIO INPUT WILL RECEIVE HIGHEST PRIORITY AND

OVERRIDE ALL FIRE ALARM NOTIFICATION SO LONG AS

THE INPUT IS ACTIVE. WHEN THE INPUT GOES INACTIVE

(CONTACT OPEN) THE EXTERNAL AUDIO ROUTING WILL

CEASE AND THE FIRE ALARM PANEL MUST

AUTOMATICALLY RETURN TO THE PRIOR NOTIFICATION

PROGRAM THAT WAS ACTIVE BEFORE THE MNS

MESSAGE.

5. FACP MUST BE COMPATIBLE AND OPERABLE WITH THE

EXISTING FIRE ALARM SUPERVISING STATION

SHUREGUARD III. EXISTING BASEWIDE MASS

NOTIFICATION REPORTING SYSTEM IS A COOPER

INDUSTRIES WAVES SYSTEM. CONTRACTOR MUST

PROVIDE ALL EQUIPMENT AND LABOR REQUIRED TO

CONNECT THE NEW FIRE ALARM AND DETECTION

SYSTEM TO THE BASE'S SUPERVISING STATION. WAVES

SYSTEM TRANSCEIVER TO BE PROVIDED BY THE

GOVERNMENT.

6. DACT MUST BE CONFIGURED TO TRANSMIT SIGNALS IN

CONTACT ID FORMAT.

7. SIGNALS TRANSMITTED OVER THE PRIMARY AND

SECONDARY MEANS OF TRANSMISSION MUST BE POINT

SPECIFIC WITH EACH ADDRESS AND CONDITION

INDICATED AT THE FIRE ALARM PANEL TRANSMITTED

SEPARATELY. ALL FIRE ALARMS, SUPERVISORY ALARMS,

AND TROUBLE CONDITIONS MUST BE TRANSMITTED TO

THE SUPERVISING STATION. CONNECTION TO THE FIRE

ALARM REPORTING SYSTEM AND PROGRAMMING OF THE

DACT MODULE AND HEAD END EQUIPMENT SHUREGUARD

III MUST BE COORDINATED WITH THE FIRE ALARM

REPORTING SYSTEM (FARS) ADMINISTRATOR.

8. PROVIDE A DOCUMENT CABINET ADJACENT TO FACP.

CABINET MUST BE STEEL, LOCKING, WITH A

HINGE-MOUNTED DOOR, KEYED THE SAME AS THE FACP.

PROMINENTLY LABEL THE EXTERIOR OF THE CABINET

"SYSTEM RECORD DOCUMENTS". CABINET MUST

INCLUDE PAPER COPIES AND A CD OF FIRE ALARM

AS-BUILT DRAWINGS, LIST OF CONTACT ID DESCRIPTIONS

FOR THE FIRE ALARM ADDRESSABLE DEVICES, NFPA 72

RECORDS OF COMPLETION. CD MUST INCLUDE

SITE-SPECIFIC SOFTWARE AND O&M MANUALS STORED

IN A CD JEWEL CASE. PROVIDE A LAMINATED GRAPHIC

FLOOR PLAN SIZE 22"X34" ADJACENT TO THE FACP AND

MAIN ENTRANCE TO BUILDING ADJACENT TO THE

ANNUNCIATOR. THE DRAWING MUST DEPICT ALL FIRE

ALARM DEVICES, REMOTE POWER SUPPLY PANELS, AND

ASSOCIATED EQUIPMENT WITHIN THE FACILITY. THE

DRAWING MUST ALSO INCLUDE ROOM NUMBERS.

9. FIRE ALARM PLANS INDICATE AREA OF STROBE

COVERAGE AND ARE DIAGRAMMATIC ONLY.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING

ADDITIONAL SPEAKERS FOR EACH FACILITY TO MEET ALL

MASS NOTIFICATION SYSTEM INTELLIGIBILITY

REQUIREMENTS IN ACCORDANCE WITH UFC 4-021-01.

10. INSTALL COOPER WHEELOCK SERIES STH-155

SUPERVISED HORN LOUDSPEAKER OUTSIDE OF

BUILDING.

11. LABEL ALL DEVICES WITH THEIR ADDRESSES.

12. PROVIDE ACCESS FOR THE CAMP LEJEUNE FIRE AND

EMERGENCY SERVICES FIRE ALARM TECHNICIANS TO

UNINSTALL AND RETRIEVE FIRE ALARM PANELS,

SYSTEMS AND COMPONENTS PRIOR TO THE DEMOLITION

OF EXISTING BUILDINGS, POC IS DAVID JONES (910)

376-0437.

FIRE ALARM AND MNS MONITORING NOTES

EXISTING

4100ES

NO SCALE

FIRE ALARM/MASS NOTIFICATION INPUT-OUTPUT MATRIX

AC

TU

AT

E

CO

M

M

ON

A

LA

RM

S

IG

NA

L

AC

TU

AT

E

AU

DI

BL

E

AL

AR

M S

IG

NA

L

AC

TU

AT

E

CO

M

M

ON

S

UP

ER

VI

SO

RY

S

IG

NA

L

IN

DI

CA

TO

R

AC

TU

AT

E

AU

DI

BL

E

SU

PE

RV

IS

OR

Y

SI

GN

AL

AC

TU

AT

E

CO

M

M

ON

T

RO

UB

LE

S

IG

NA

L

IN

DI

CA

TO

R

AC

TU

AT

E

AU

DI

BL

E

CO

M

M

ON

T

RO

UB

LE

S

IG

NA

L

AC

TI

VA

TE

D

IS

PL

AY

O N

FA

CP

A

ND

A

NN

UN

CI

AT

OR

S

AC

TU

AT

E

AU

DI

BL

E

EV

AC

UA

TI

ON

SI

GN

AL

S

VO

IC

E M

ES

SA

GE

AC

TI

VA

TE

V

IS

UA

L

EV

AC

UA

TI

ON

S

IG

NA

LS

TR

AN

SM

IT

F

IR

E

AL

AR

M

S

IG

NA

L

TO

S

UP

ER

VI

SI

NG

S

TA

TI

ON

TR

AN

SM

IT

S

UP

ER

VI

SO

RY

S

IG

NA

L

TO

S

UP

ER

VI

SI

NG

S

TA

TI

ON

TR

AN

SM

IT

T

RO

UB

LE

S

IG

NA

L

TO

S

UP

ER

VI

SI

NG

S

TA

TI

ON

OV

ER

RI

DE

O

TH

ER

M

ES

SA

GE

S, A

CT

IV

AT

E

AU

DI

BL

E

AN

D

VI

SU

AL

S

IG

NA

LS

CONTROL UNIT ANNUNCIATION NOTIFICATION SUPP.

SYSTEM INPUTS BELOW A B C D E F G H I J K L M

1 MANUAL FIRE ALARM BOXES X X X X X X 1

2 SMOKE DETECTORS X X X X X X 2

3 3

WATERFLOWS X X X X X X

SPRINKLER CONTROL VALVES TAMPER SWITCH X X X X

FIRE ALARM AC POWER FAILURE X X X X

FIRE ALARM SYSTEM LOW BATTERY X X X X

OPEN CIRCUIT X X X X

GROUND FAULT X X X X

NOTIFICATION APPLIANCE CIRCUIT SHORT X X X X

BASEWIDE MASS NOTIFICATION MESSAGE ACTIVE X

A B C D E F G H I J K L M

SYSTEM OUTPUT BELOW

LOCAL OPERATING CONSOLE (LOC) X

TRX-401

TRANSCEIVER

SFS

WP

SF F S

FINISHED WALL

WALL MOUNTED

SMOKE/HEAT DETECTOR

CEILING MOUNTED

SMOKE/HEAT DETECTOR

ACCEPTED HERE

4" 12"

MAX

CEILING

3' MINIMUM

A/C SUPPLY OR

RETURN DIFFUSER

MAGNETIC

DOOR

HOLDER 5"

DOOR

WIDTH

LESS 3"

MANUAL

PULL

STATION

TO EXIT DOOR

5' MAXIMUM

FIRE

PHONE

JACK 42"MIN TO 48" MAX

TO TOP OF PULL

HANDLE

92" MIN AFF

AUDIBLE

ONLYAUDIBLE/VISUAL &

VISUAL ONLY

APPLIANCES

SYNCHRONIZE MORE

THAN TWO

APPLIANCES IN ANY

FIELD OF VIEW.

F I R EF I R E

FOR CEILING HEIGHTS LESS THAN 86" THE

VISUAL LENS MOUNTING HEIGHT MUST BE

WITHIN 6" OF THE CEILING

96"

MAXIMUM

AFF

80"

MINIMUM

AFF

FINISHED FLOOR

NO SCALE

FIRE ALARM SYSTEM DEVICE MOUNTING HEIGHT DETAIL

NO SCALE

NOTE: MEASUREMENTS

SHOWN ARE TO THE CLOSEST

EDGE OF THE DETECTOR

6" MINIMUM BFC

NO SCALENO SCALE

LOCAL OPERATORS CONSOLELOC

D DUCT SMOKE DETECTOR

REMOTE TEST / RESET DEVICERT

02/24/20

EXISTING CHAPEL

( BUILDING 17 )

ADDITION

( BUILDING 17A )

SF

TO OTHER

ADDRESSABLE

DEVICES

F S H D

RT

TO AHU

SHUTDOWN

TO OTHER

ADDRESSABLE

DEVICESS

WP

SS

120VAC

MNS

REMOTE

NEW FACP

F S S

F RT S

H

D

SS

RT

SH

S

D

FACP

S

SWP F LOC

FAA

F S

F S WP

S

WP

VESTIBULE

CONFESSIONAL

SANCTUARY

ALTAR

CHANGING

ROMM

CORR.

JAN.

UNISEX

ELEC.

S

STORAGE

MEZZANINE The Walker Group Architecture, Inc

PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

NDEMOLITION FIRST FLOOR PLAN

SCALE: 1/8" = 1'-0"

NDEMOLITION MEZZANINE FLOOR PLAN

SCALE: 1/8" = 1'-0"

1 REMOVE EXISTING FIRE ALARM CONTROL PANEL TO BE RELOCATED.

REFER TO SHEET FA101 FOR NEW LOCATION.

NOTES THIS SHEET

DUE TO THE REMOVAL AND RELOCATION OF THE EXISTING FACP, THE FIRE ALARM SYSTEM MUST UNDERGO AS MUCH MINIMAL DOWN TIME AS POSSIBLE. IF THIS DOWNTIME WERE TO OCCUR AFTER CONSTRUCTION HOURS, CONTRACTOR MUST COORDINATE WITH CAMP LEJEUNE PERSONNEL TO CONDUCT FIRE WATCH DURING THESE HOURS.

FIRE ALARM/MASS NOTIFICATION OPERATION NOTE:

02/24/20

20 CF

0.5

S

WP

S

F RT S

H

D

SS

RT

FH

S

D

S

SWP F LOC

FAA

F S

F S WP

FACP

S

S

F

F

S

S

S

WP

S

WP

S

WP

S

WP

S

WP

S

S

F

S

S

WP

S H

F

F

F

F

F

S

F

F

NAC

VESTIBULE

CONFESSIONAL102

STORAGE

CHAPEL

ALTAR

CORRIDOR

STORAGE

VESTIBULE

UNISEX

MECH.

BABYSITTING

PANTRY

KITCHEN

FELLOWSHIP HALL

MENS 306

WOMENS

TELECOM 309

MECH/ELEC.

OFFICE

OFFICE

VESTIBULE

CORRIDOR

JAN.

UNISEX

LOC

S

S

The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.NCONSTRUCTION FIRST FLOOR PLAN

SCALE: 1/8" = 1'-0"

REINSTALL FIRE ALARM CONTROL PANEL THIS LOCATION. REWORK/EXTEND

CIRCUITRY AS NEEDED. TESTING OF SYSTEM MUST BE DONE UPON

COMPLETION OF PROJECT TO ENSURE INTEGRITY OF SYSTEM WAS KEPT

INTACT DURING CONSTRUCTION.

PROVIDE (1) 1-1/4"C, SCH. 80 PVC DIRECT BURIED 24" BFG, WITH 2/C, 18AWG

STP, OSP RATED CABLE FROM EXISTING FACP TO NOTIFICATION EXTENDER

PANEL IN NEW ADDITION.

NOTES THIS SHEET

NNEW WORK MEZZANINE FLOOR PLAN

SCALE: 1/8" = 1'-0"

The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

LEGEND & ABBREVIATIONS

TELECOMMUNICATIONS

TELECOMMUNICATIONS BACKBOARD

4" CONDUIT SLEEVE

DDC OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG PLASTER RING

AND SINGLE GANG COVERPLATE TO MATCH ELECTRICAL OUTLET

COVERPLATE MATERIAL AND COLOR, COORDINATE MOUNTING HEIGHT

WITH DDC VENDOR PRIOR TO INSTALLATION, WITH 1 1/4"C WITH (1) 2

STRAND, SMFO CABLE. STUB CONDUIT TO CABLE TRAY AND

TERMINATE WITH GROUNDING BUSHING. CONTINUE CABLING IN CABLE

TRAY TO TELECOM ROOM.

TELEPHONE OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG

PLASTER RING AND SINGLE GANG COVERPLATE TO MATCH

ELECTRICAL OUTLET COVERPLATE MATERIAL AND COLOR, 46"

AFF, UON, WITH 1 1/4"C WITH (1) CAT6 UTP CABLE (GREEN VOICE),

STUB CONDUIT TO CABLE TRAY AND TERMINATE WITH

GROUNDING BUSHING. CONTINUE CABLING IN CABLE TRAY TO

TELECOM ROOM.

GENERAL SPECIAL SYSTEMS

THE GENERAL CONTRACTOR SHALL PROVIDE A COMPLETION SCHEDULE, BROKEN DOWN

BY VARIOUS CONSTRUCTION PHASES, FOR TURN OVER OF COMPLETED ROUGH-IN FOR

CONTRACTOR TO FINISH WORK. THE CONTRACTOR SHALL COORDINATE TURN OVER WITH

VENDORS, AND SHALL TURN OVER AREAS WITH ADEQUATE TIME FOR VENDOR FINISH

WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY EXTRA VENDOR COST

RESULTING FROM INCORRECT SYSTEMS ROUGH-IN.

THE GENERAL CONTRACTOR SHALL PROVIDE IN-WALL REINFORCEMENT AS NECESSARY

FOR ALL SYSTEMS CABINETS, SHELVES, BRACKETS, FURNITURE MOUNTS, ETC.. AND

SHALL MOUNT CABINETS, SHELVES, BRACKETS, AND FURNITURE MOUNTS IN

ACCORDANCE WITH DRAWINGS, VENDOR SUBMITTALS, AND ALL APPLICABLE CODES.

THE CONTRACTOR SHALL COORDINATE AND PROVIDE ALL REQUIRED RACEWAY SYSTEMS

FOR ALL SPECIAL SYSTEMS INCLUDING CONDUIT WITH PULL STRING, JUNCTION BOXES,

GROUNDING, BACKBOARDS, POWER CONNECTIONS, ETC. THE CONTRACTOR SHALL

COORDINATE ALL ROUGH-IN, BOX SIZES AND CONFIGURATIONS, CONDUIT SIZES AND

ROUTING WITH THE VENDOR PRIOR TO INSTALLATION OF THE RACEWAY SYSTEM.

THE CONTRACTOR SHALL PROVIDE ALL CABLING AND WIRING (EXCEPT POWER WIRING),

CABLE TRAY, JACKS, COVER PLATE COMPATIBLE WITH THE EQUIPMENT, DEVICES, RACKS,

AND COMPONENT EQUIPMENT UNLESS OTHERWISE NOTED.

FINAL DEVICE LOCATIONS AND ELEVATIONS SHALL BE COORDINATED WITH

ARCHITECTURAL PLANS, CASEWORK AND ELEVATIONS, AND VENDOR REQUIREMENTS.

TELEPHONE AND DATA SYSTEMS

THE TELEPHONE AND DATA SYSTEMS WILL BE THROUGH THE CONTRACTOR. THE

CONTRACTOR SHALL PROVIDE A COMPLETE RACEWAY SYSTEM AS INDICATED.

ALL CONDUITS SHALL BE 1 1/4" MINIMUM, SHALL HAVE A PULL WIRE AND SHALL BE

TERMINATED WITH INSULATED GROUNDING BUSHING. ALL TELEPHONE, DATA AND CABLE

TELEVISION BOXES SHALL BE 5" X 5" X 2 7/8" DEEP WITH A SINGLE GANG RISE AND BLANK

COVER PLATE UNLESS OTHERWISE INDICATED. COORDINATE CONDUIT QUANTITIES,

SIZES AND LOCATIONS.

THE BUILDING SHALL BE PRE-WIRED BY THE VENDOR DURING CONSTRUCTION PRIOR TO

CLOSING THE WALL CAVITIES.

STUB ALL CONDUITS WITH PULL WIRE FOR COMMUNICATIONS DEVICE OUT TO CABLE

TRAY AND PROVIDE INSULATED GROUND BUSHING. WHERE A FULL WALL SEPARATES THE

CONDUIT STUB OUT FROM THE DESTINATION ROOM, PROVIDE A 1 1/2" MINIMUM SLEEVE

THROUGH THE WALL, ABOVE AN ACCESSIBLE CEILING, TO ACCOMMODATE THE CABLING.

PROVIDE ALL CONDUITS AND SLEEVES PENETRATING RATED FIRE OR SMOKE WALLS

WITH APPROVED FIRE RETARDANT TO PROVIDE A UL RATED ASSEMBLY. MAINTAIN

VENDOR RECOMMENDED SEPARATION BETWEEN WIRING OF DIFFERENT SYSTEMS AND

FROM INTERFERENCE PRODUCING ELECTRICAL DEVICES SUCH AS FLUORESCENT

LIGHTS, BALLASTS, TRANSFORMERS, RELAYS, MOTOR CONTROLS, ETC..

GENERAL SPECIAL SYSTEM NOTES

REQ'D REQUIRED

PNL PANEL

NATIONAL ELECTRICAL CODENEC

GROUNDGND

EXIST EXISTING

EXISTING TO REMAINETR

CONDUIT C

RACK UNITRU

AREA OF REFUGE ASSISTANCEARA

ABBREVIATIONS

ABOVE FINISHED GRADEAFG

ABOVE FINISHED FLOORAFF

FMCP FIRE ALARM/MASS NOTIFICATION CONTROL PANEL

BELOW FINISHED GRADEBFG

BUILDING ENTRANCE PROTECTORBEP

TELECOMMUNICATIONS MAIN GROUND BUS BARTMGB

DDC OUTLET

NO SCALE

1-1/4"C TO CABLE TRAY

DDC

BLANK

385 A 386

5" X 5" X 2 1/8" BOX

1-1/4"C TO CABLE TRAY

5" X 5" X 2 7/8" BOX

MOUNTING STUDS

(1) 4 PAIR 24 AWG COPPER

CAT 6 UTP, GREEN CABLES

(1) GREEN CAT 6 UTP RJ45

JACKS

TELECOMMUNICATIONS RISER DIAGRAM

NO SCALE

FIRST FLOOR310

(4) CAT6 UTP

(TYP. FOR ALL TELE/DATA OUTLETS)

NEW BUILDING - 17A EXISTING CHAPEL

BET BUILDING ENTRANCE TERMINAL

NOTE:

(2) 4"C, SCH. 80PVC, DIRECT BURIED 24" BFG MIN. (1) 4"C TO INCLUDE (1) 1-1/4"C WITH / (1) 3" 3-CELL MAXCELL FABRIC INNERDUCT WITH (1) 12 STRAND SMFO, OSP RATED

CABLE. (1) 4"C WITH (1) 25 PAIR COPPER TELEPHONE CABLE, OSP RATED TO RP-5. FIBER DEMARC LOCATION TO BE DETERMINED BASE TELEPHONE.

(1) 3"C., SCH.80 PVC, DIRECT BURIED 24"BFG MIN WITH (1) 3" 3-CELL MAXCELL FABRIC INNERDUCT WITH (1) 6 STRAND SMFO CABLE, OSP RATED (INSTALLED IN INNERDUCT), WITH (1) 12 PAIR TELEPHONE CABLE, OSP RATED.

(1) 4 PAIR 24AWG COPPER

(TYP. FOR TELEPHONE ONLY OUTLETS)

DDC

25RU WALL MOUNTED CABINET,

FIBER OPTIC DISTRIBUTION PANEL,

CAT 6 PATH PANEL, FIBER PATCH

PANEL, CABLE MANAGMENT, FAN,

LOCKABLE.

WALL TELEPHONE OUTLET

NO SCALE

PB PULLBOX, TYPE 8. SEE DETAIL THIS SHEET.

(1) 2 STRAND SMFO CABLE

(1) DUPLEX "SC" TYPE JACK

385 A 386

BET

TMGB

PB

FREE STANDING 7'

EQUIPMENT RACK

3"PVC, SMART

TYPE ELBOW

WINDOW

TMGB

BET

COMBINATION TELEPHONE / DATA JACK

NO SCALE

(4) 4 PAIR 24 AWG COPPER CAT

6 UTP, GREEN CABLES FOR

EVEN NUMBERED JACKS

(2) DUAL MOLDED 8P8C JACKS

387 A 388

5" X 5" X 2 1/8" BOX

GREEN COMPUTER ICON -

EVEN NUMBERS

GREEN TELEPHONE

ICON - ODD NUMBERS 387 A 388

DIGITAL DATA CONTROLDDC

TELE/DATA OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG PLASTER

RING AND SINGLE GANG COVERPLATE TO MATCH ELECTRICAL OUTLET

COVERPLATE MATERIAL AND COLOR, 18" AFF, UON, WITH 1 1/4"C WITH

(4) CAT 6 UTP CABLE (2 GREEN VOICE / 2 GREEN DATA). STUB CONDUIT

TO CABLE TRAY AND TERMINATE WITH GROUNDING BUSHING.

CONTINUE CABLING IN CABLE TRAY TO TELECOM ROOM.

DDC

LADDER TYPE CABLE TRAY

WIRE BASKET TYPE CABLE TRAY

1-1/4"C TO CABLE TRAY

30" X 48" X 24" DEEP

24" X 36" X 24" DEEP

12" X 24" X 24" DEEP

12" X 18" X 24" DEEP

12" X 12" X 24" DEEP

HANDHOLE SIZING

PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR "TELEPHONE" FOR TELEPHONE

PROVIDE WITH (2) 2 1/2" MOUSEHOLES.

PROVIDE STAINLESS STEEL BOLTS AND INSERTS.

10" x 10" AREA.

COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A

REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.

HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS

5.

4.

3.

2.

HANDHOLES, OR AS INDICATED.

REQUIRED

BOX WHEN

SECTIONAL

1.

HANDHOLE REQUIREMENTS

TYPE

CRUSHED ROCK

6"

EARTH

COMPACTED

PULL SLOT

SURFACE

RESISTANT

SKID

L

A

B

E

L

HEX BOLT AND

WASHER

STAINLESS STEEL

COVER

BOX AND

AROUND BOX

6"

CONCRETE RING

10"

6"

UG-6

JUNE 2002

(COMPOSITE/FIBERGLASS) TYPES 5, 6, 7, 8 & 9

STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC)

SKETCH DATE STYLE

LADDER CABLE TRAY DETAIL

NO SCALE

NOTES:

1. CONTRACTOR SHALL PROVIDE PATHWAY FOR ALL LISTED SYSTEMS CABLING. TRAY MUST COMPLY WITH NEC FOR

CABLE TRAY FILL REQUIREMENTS. IN NO CASE MAY THE CABLE TRAY BE LESS THAN THE STATED MINIMUM SIZE.

2. MOUNT CABLE TRAY AT A MINIMUM OF 12" BELOW MECHANICAL DUCT WORK BUT AS HIGH AS POSSIBLE TO AVOID

TAMPERING.

3. TYPICAL MOUNT OVER RACKS IN TELCOM ROOM.

TYPICAL HANGER. SUPPORT FROM STRUCTURE

ABOVE. SPACE AT 60" ON CENTER AND WITHIN 24"

OF ENDS MINIMUM.

TYPICAL CONDUIT STUBBED ABOVE

CABLE TRAY WITH BUSHING. PROVIDE #6

AWG GROUND BETWEEN CONDUIT AND

#2 AWG CABLE TRAY GROUND WIRE.

TYPICAL CONDUIT STUBBED

THROUGH WALL TO ABOVE

CABLE TRAY WITH BUSHING.

PROVIDE #6 AWG GROUND

BETWEEN CONDUIT AND #2

AWG CABLE TRAY GROUND

WIRE.

SIZE AS INDICATED

CABLE TRAY

GROUND WIRE, #2.

MOUNT TO SIDE OF

CABLE TRAY.

2" MIN

G

G

G

G

#6 BOND GROUND

WIRE TO CABLE

TRAY GROUND

WIRE

#6 BOND GROUND

WIRE TO CABLE

TRAY GROUND

WIRE

NO SCALE

2" MIN.

NOTES:

2. MOUNT CABLE TRAY AT A MINIMUM OF 12" BELOW MECHANICAL DUCT WORK BUT AS HIGH AS POSSIBLE TO AVOID

TAMPERING.

3. TYPICAL MOUNTING METHOD.

PROVIDE MANUFACTURER RECOMMENDED

COUPLING TO SECURELY CONNECT AND

GROUND SECTIONS OF CABLE TRAY.

TYPICAL HANGER. SUPPORT

FROM STRUCTURE ABOVE.

SPACE AT 60" ON CENTER

AND WITHIN 24" OF ENDS

MINIMUM.

TYPICAL CONDUIT STUBBED THROUGH WALL TO

ABOVE CABLE TRAY WITH BUSHING. PROVIDE #6

AWG GROUND BETWEEN CONDUIT AND #2 AWG

CABLE TRAY GROUND WIRE.

#6 BOND GROUND

WIRE TO CABLE

TRAY GROUND

WIRE

CABLE TRAY GROUND

WIRE, #2.

MOUNT TO SIDE OF

CABLE TRAY

SIZE AS INDICATED

G

G

G

#6 BOND TO CABLE

TRAY GROUND

BONDING CLAMP

1. CONTRACTOR SHALL PROVIDE PATHWAY FOR ALL LISTED SYSTEMS CABLING. TRAY MUST COMPLY WITH UFC 3-580-1

FOR CABLE TRAY FILL REQUIREMENTS. IN NO CASE MAY THE CABLE TRAY BE LESS THAN THE STATED MINIMUM SIZE.

WIRE BASKET CABLE TRAY DETAIL - ABOVE CEILING

TYPICAL GROUND BUS BAR DETAIL

NO SCALE

LESS THAN 4 (13)

4 - 6 ( 14 - 20 )

6 - 8 ( 21 - 26 )

8 - 10 ( 27 - 33 )

10 - 13 ( 34 - 41 )

13 - 16 ( 42 - 52 )

16 - 20 ( 53 - 66 )

20 - 26 ( 67 - 84 )

26 - 32 ( 85 - 105 )

32 - 38 ( 106 - 125 )

38 - 46 ( 126 - 150 )

46 - 53 ( 151 - 175 )

53 - 76 ( 176 - 250 )

76 - 91 ( 251 - 300 )

GREATER THAN 91 ( 301 )

TBB - TELECOMMUNICATIONS BONDING BACKBONE

TBC - TELECOMMUNICATIONS BONDING CONDUCTOR

1/0

2/0

3/0

4/0

250kcmil

300kcmil

350kcmil

500kcmil

600kcmil

750kcmil

TBB/TBC SIZE (AWG)TBB/TBC LENGTH M (FT)

COPPER BASED BOLTS, NUTS, & LOCK

WASHERS (TYPICAL)

STAND-OFF INSULATOR, 1KV MINIMUM

(2" MINIMUM OFFSET) (TYPICAL)

COPPER MAIN TELECOMMUNICATIONS

GROUND BUS BAR ( )

4" x 12" x 1/4" THICK (TYPICAL)

TMGB

(1) #6 CU GND IN 3/4"C. CONNECT TO

ELECTRICAL PANEL GROUND ELECTRODE

SYSTEM PER NEC ARTICLE 800

TO BUILDING

STEEL

TO CABLE TRAY

TO TELECOM CABINET

MOUNTING BRACKET(S)

FACTORY DRILLED HOLES (TYPICAL)

CONTRACTOR SHALL SIZE

TELECOMMUNICATIONS GROUNDING

AND BONDING INFRASTRUCTURE

PER ANSI J-STD-607-D

EXISTING PLYWOOD BACKBOARD

8-POSITION, 8-CONDUCTORS8P8C

CATEGORYCAT

UNLESS OTHERWISE NOTEDUON

UNSHEILDED TWISTED PAIRUTP

B E

T T

M G

B

12" X 2" LADDER

TYPE CABLE TRAY

(2) 4"C

20 CF

E F G H

0.5

B.1 B.7BA C D

I J K L M N O P

DDC

VESTIBULE

CONFESSIONAL102

STORAGE

CHAPEL

ALTAR

CORRIDOR

STORAGE

VESTIBULE

UNISEX

MECH.

BABYSITTING

PANTRY

KITCHEN

FELLOWSHIP HALL

MENS

WOMENS

TELECOM

MECH/ELEC.

OFFICE

OFFICE

VESTIBULE

CORRIDOR

JAN.

UNISEX

PB

3"C, MIN 24" BFG

T-101

6" X 2" WIRE

BASKET TYPE

CABLE TRAY

BET

TMGB

DDC

The Walker Group Architecture, Inc PO Box 541, New Bern, NC 28563

252.636.8778 (PHONE)

252.636.8992 (FAX)

WALKER

GROUP

i n c o r p o r a t e d the

ARCHITECTURE

DISCLOSURE OF INFORMATION

CONTRACTOR SHALL COMPLY AS FOLLOWS:

(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE

(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL

SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION

TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.

1 REMOVE EXISTING TELECOMMUNICATIONS EQUIPMENT, SALVAGE

EXISTING HORIZONTAL CABLES. RECONNECT EXISTING HORIZONTAL

CABLES TO NEW WALL MOUNTED CABINET.

NOTES THIS SHEET

1/8" = 1'-0"

5'0'5' 10' 20'

NCONSTRUCTION FIRST FLOOR PLAN

SCALE: 1/8" = 1'-0"

ENLARGED PLAN - TELECOM ROOM

SCALE: 1/4" = 1'-0" T-101

1/4" = 1'-0"

5' 10'0' 5'

60025701
60025702
60025703
60025704
60025705

File details come from the government source that posted it. Updated .