This document contains three sheets providing technical specifications and drawings for an existing crane and runway at a federal facility. Key details include specifications for Crane 124-3, which has a 21'6" span and 7,750 pound maximum allowable load. Dimensional details and clearances are provided for the crane, runway supports, and electrification requirements. Also included are notes clarifying scope assumptions. The related federal contract opportunity is solicitation N62470-18-R-2007 for a Weight Handling Equipment Multiple Award Contract to fulfill requirements for the Navy, Marine Corps, and other federal activities. Awards under the WHEMAC will include procurement of new equipment and designs as well as reconstitution and overhaul of existing equipment.
Appendix A-1 (Rev. 1)
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| N6247018R2007_Amend._0001.pdf | ||
| J11_(Rev._1)_Appendix_A-2_Crane_124_4_AMEND_0003.pdf | ||
| Amendment_0003.pdf | ||
| J12_(Rev._1_)_Lakehurst_Base_Specification_-_CLIN_001_and_CLIN_002_AMEND_0003.pdf | ||
| J7._Payment_Bond,_SF_1416.pdf | ||
| J8._Wage_Determination.pdf | ||
| J2._Price_Proposal_Sheet.pdf | ||
| J3._Past_Performance_Questionnaire_Cover_Sheet.pdf | ||
| J1._Seed_Project_Specification.pdf | ||
| J5._Bid_Bond,_SF_24.PDF | ||
| J6._Performance_Bond,_SF_1418.pdf | ||
| N6247018R2007_Small_WHEMAC.pdf | ||
| J9._Pre-proposal_Inquiry_Form.xlsx | XLSX spreadsheet | |
| J4._Past_Performance_Questionnaire.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A (Span - Centerline to Centerline of Runway Rails)
Centerline of Hooks
J (measured from highest point on crane)
Lowest obstruction e.g. roof truss, lights, sprinklers, etc.
II
D
C
E
L M
N
H
B
O
Pit
Floor
Operating Floor
F
G
A (Span - Centerline to Centerline of Runway Rails)
K
K
P
Q Q
Existing Crane Wheel Spacing
(for Top Running Crane)
Obstruction
Crane 124-3
2 TON UNDER-RUNNING UNDER-HUNG
ELEVATION VIEW X-X
TOP RUNNING CRANE
-RAIL SIZE: ______ lbs./yard
-MAXIMUM ALLOWABLE WHEEL LOAD
EXCLUDING IMPACT: ________ lbs
UNDER RUNNING CRANE
-RUNWAY TYPE:
-MAXIMUM ALLOWABLE LOAD
AT RUNWAY TRACK BEAM SUPPORT
POINT, EXCLUDING IMPACT: ________ lbs
Appendix A- 1
Sheet 1 of 3 Rev. -
A:
B:
C:
D:
E:
F:
G:
H:
I:
J:
K:
L:
M:
N:
O:
P:
Q:
21' - 06"
27' - 01"
N/A
3' - 00"
3' - 00"
N/A
4' - 00"
2"
3"
1' -04"
N/A
N/A
N/A
N/A
N/A
N/A max.
max.
ref.
min.
min.
min.
max.
Crane Information and Clearance Sketch
W
NOTES:
1. Drawing is not to scale
2. Dimensions were measured in the field as no drawing data was available to NCC.
Contractor is responsible for verifying dimensions prior to crane and runway design.
3. Distance is from floor to bottom face of W12x45 facility support structure.
4. Separate messenger track required.
5. Minimum lift needed is 27' - 01" (15'-01" to the floor, plus ~12'-00" to pit table)
N/A
7,750
N/A
PATENTED TRACK
min.
19' - 10"
See Note 3
See Note 4
See Note 5
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
FF
HH
GG
Span (see Sheet 1)
BB
AAAA
CC
EE
DD
Obstruction
Crane End Stop
(Typ, 4 Places)
Centerline of hook when crane is against the stops
Centerline of hook when crane is against the stops
Appendix A-1
Sheet 2 of 3 Rev. -
AA:
BB:
CC:
DD:
EE:
FF:
GG:
N/A ref.
Building Information and Sketch
W
NOTES:
1. This distance is from end stop face to end stop face. New end stops shall be placed where existing end stops are located.
2. This dimension is the existing dimension from face of end stop to CL hook.
3. New Disconnect will be in the same place as the exisiting one on beam, except relocated to the floor.
5' - 00"
5' - 00"
38' - 00"
N/A
N/A
N/A
CRANE ELECTRIFICATION
Voltage:
Amperage:
Frequency:
Phase:
max.
max.
max.
EXISTING RUNWAY CONDUCTOR CONFIGURATION
Horizontal or Vertical:
Manufacturer:
Model Number:
N/A - To be replaced
N/A - To be replaced
N/A - To be replaced
VAC
Amp
Hz
HH: N/A
max.
PLAN VIEW Crane 124-3
Crane
Disconnect
Crane
Electrification this side
See Note 2
See Note 2
See Note 1
Runway Patented
Track Support
Location. Runway will attach to W12x45.
Max. Allowable Load
7,750 lbs
Typ 6 Places
Runway Track
W12 x 45
Facility Structure
Typ 3 Places
21' - 06"
DRAWING NOT TO SCALE
17' - 00"
Runway Span
Appendix A-1
Sheet 3 of 3 Rev. -
Additional Information
RUNWAY SUPPORT LOCATIONS
124-3
W
Amendment 0003 Work Order 1562198
| Sheets and Views |
| Appendix A Crane 124_3-Sheet 1 |
| Appendix A Crane 124_3-Sheet 2 |
| Appendix A Crane 124_3-Sheet 3 |
File details come from the government source that posted it. Updated .