N62470-20-R-4012 Synopsis.pdf

PDF 150 KB Posted

Attached to
AE IDIQ BASE CONTRACT: Cost Estimating Services Federal contract opportunity
Solicitation number
N62470-20-R-4012
Issued by
Department of the Navy Naval Facilities Engineering Command

View the file

Other files for this federal contract opportunity

Other files attached to AE IDIQ BASE CONTRACT: Cost Estimating Services, newest first.
File Type Posted
Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
Attachment A - Past Performance Questionnaire (PPQ).pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N62470-20-R-4012 INDEFINITE DELIVERY/INDEFINITE QUANTITY CONTRACT FOR

ARCHITECT-ENGINEER SERVICES FOR COST ENGINEERING AND RELATED

SERVICES FOR PROJECTS LOCATED THROUGHOUT THE NAVAL FACILITIES

ENGINEERING COMMAND ATLANTIC AREA OF OPERATIONS, WORLDWIDE.

Description: ALL INFORMATION NEEDED FOR INTERESTED PARTIES TO SUBMIT A

STANDARD FORM SF-330, ARCHITECT ENGINEER QUALIFICATIONS IS

CONTAINED HEREIN. THERE IS NO SEPARATE REQUEST FOR PROPOSALS (RFP)

PACKAGE TO DOWNLOAD.

Attachments: (a) Past Performance Questionnaire

This procurement will result in one Indefinite Delivery/Indefinite Quantity (IDIQ) contract for multi-discipline Architect-Engineer (AE) services for multi-discipline Architect-Engineer (AE) services for Cost Engineering Services throughout the Naval Facilities Engineering Systems Command Atlantic Area of Operations, but may also include work worldwide. These services will be procured in accordance with 40 USC Chapter 11, Selection of Architects and Engineers, as implemented by FAR Subpart 36.6. The IDIQ contract will be for a base period of one year and four one-year option periods (if exercised). The total fee for the contract term shall not exceed $15,000,000. The guaranteed minimum for the contract term (including option years) is $5,000. Firm-fixed price task orders will be negotiated for this contract. There will be no dollar limit per task order and no dollar limit per year. Estimated start date is April 2024.

This proposed contract is being solicited on a 100 percent Service-Disabled Veteran-Owned Small Businesses (SDVOSB) set aside; therefore, replies to this notice are requested from SDVOSB concerns. The Small Business size standard classification is North American Industrial Classification System (NAICS) Code 541330, Engineering Services. The Government seeks the most highly qualified firm to perform the required services, based on the demonstrated competence and qualifications, in accordance with the selection criteria.

The market research study N62470-20-R-4012 Cost Estimating Services conducted by NAVFAC Atlantic included an assessment of relevant qualifications and capabilities of potentially qualified firms. As a result of the market research analysis, a determination was made to set aside this procurement for 100 percent Service-Disabled Veteran-Owned Small Businesses. The NAVFAC Atlantic small business office concurs with this decision.

The type of Architect-Engineer (AE) services expected to be performed under this contract are Cost and Supporting Engineering Services including but not limited to:

1. Development and preparation of detailed cost estimates for complex facilities encompassing horizontal and vertical construction. This may include specialties such as dredging, hazardous and toxic materials remediation, unexploded ordinance location, waterfront facilities and contract modifications. This would be done using the latest DoD and NAVFAC approved software (MII, PACES, and RACER). This would be Class 1, 2 or 3 estimates for Design-Bid-Build or Design-Build projects

(Estimate classes as defined by the AACE International cost estimate classification system for the Building and General Construction industries.)

2. Development and preparation of concept and budget estimates for those types of projects described above. This would be done using the latest DoD and NAVFAC approved software. (Currently MII, PACES and RACER). These would be for Class 3, 4 or 5 for studies or 1391 development (Estimate classes as defined by the AACE International cost estimate classification system for the Building and General Construction industries.). This would also include rough order of magnitude estimates and alternative cost analysis.

3. Preparation of comprehensive DD Form 1391 documentation, which may include:

a. Planning deliverables: requirements definition, Basic facility requirement/facilities planning document preparation, and economic analysis for project justification.

b. 1391 Preliminary Design Charrette facilitation and report.

c. Field investigations deliverables: surveying and mapping, tests, evaluations, consultations, soil borings, hazardous materials identification.

d. Sustainable design deliverables: LEED Checklist or NAVFAC Sustainability and Energy Data Record Card, etc.

e. Cybersecurity Deliverables.

f. Design deliverables: MILCON Planning Checklist, Preliminary Collateral

Equipment list, related studies, multi-discipline conceptual designs, floor plan and site plan preparation cost estimates including Physical Security Equipment (PSE) and or Electronic Security Systems (ESS) costs if required, energy computation, life safety code studies, interior space comprehensive planning/design, conceptual designs, and other associated engineering services.

g. Familiarity with and access to NAVFAC’s Electronic Project Generator program is required.

4. Development of general and specific economic analysis, life cycle cost analysis, Total Ownership Costs and other non-present value cost analyses. These should be done using either DOD’s ECONPACK software or other energy audit type analysis package.

5. Cost and Schedule Risk Analysis (using Crystal Ball and MS Project).

6. Construction schedule development (MS Project) including contract modifications and impact analysis.

7. Value Engineering Studies and Charrette facilitation.

8. Other cost engineering support services associated with facility construction and environmental remediation such as regional construction market analysis or economic evaluation.

9. Quality Reviews (QRs) and Constructability Reviews (CRs) consisting of a study by a multi-disciplined team of professionals. For QRs, the team will concentrate on coordination aspects of the design documents, rather than technical aspects of the design. For CRs, the team will concentrate on the appropriateness of the design documents, based on the proposed materials, project location, and current standard construction practices.

10. Reports and / or detailed regional cost studies to provide guidance on enhancing the accuracy of construction cost estimates for future projects at various locations under the cognizance of NAVFAC.

11. Development and delivery of custom cost estimating training.

12. Database and cost estimating tool creation and management.

References:

Available from www.wbdg.org:

UFC1-300-09N Navy and Marine Corps Design Procedures UFC3-701-01 DOD Facilities Pricing Guide UFC3-730-01 Programming Cost Estimates for Military Construction UFC3-740-05 Handbook: Construction Cost Estimating

Available from NAVFAC upon request:

POM PDA Guidance for applicable MILCON Program Budget Year Consistency Review Board (CRB) Guidelines & DD 1391 Development Budget Quality DD 1391 Editing and Style Guidelines MTP3 Process Improvement Report dated 18 March 2008 BMS B-25.6.2.2 MILCON Project Documentation Installation/PWD 1391 Input to MTP3 BMS B-11.3.2 Regular Cycle Navy Blue MCON Region FEC Team 1391

All contractors are advised that registration in System for Award Management (SAM) Database is required prior to award of a contract. Failure to register in the SAM Database may render your firm ineligible for award. For more information, check the SAM Web site:

https://www.sam.gov.

The awarded contract will be subject to specific provisions addressing the avoidance of organizational conflicts of interest, including NPGI 9.506 – Organizational and Consultant Conflicts of Interest. The prime firm for this contract will be required to perform throughout the contract term.

Interviews may be scheduled with firms slated as the most highly qualified. Firms slated for interviews may be asked to clarify information contained in the SF330 submittal. Elaborate presentations are not desired.

SELECTION CRITERIA:

Firms responding to this synopsis will be evaluated on seven (7) criteria to determine the most highly qualified firms to perform the required services in accordance with the published selection criteria. Failure to comply with instructions, or provide complete information may affect the firm’s evaluation or disqualify the firm from further consideration. Evaluation Criteria 1 through 3 are considered the most important and are equal among themselves; Criteria 4 through 6 are of slightly less importance and are equal among themselves; and Criterion 7 is of the least importance and will be used as a tie-breaker among technically equal firms. Specific selection criteria include:

1. Specialized Experience

2. Professional Qualifications and Technical Competence

3. Past Performance

4. Quality Control

5. Program Management, Capacity and Location

6. Sustainable Design

7. Volume of Work

Criterion 1- Specialized Experience (SF-330, Part I, Section F):

Firms will be evaluated on specialized experience in performance of services similar to those anticipated under this contract through evaluation of experience in:

1. Experience in developing detailed Class 1 Cost Estimates for complex military facilities for both CONUS and OCONUS projects.

2. Experience in comprehensive DD1391 Development (with planning, economic, and design efforts) and program budget cost estimates for complex construction for all facility types for both CONUS and OCONUS projects.

3. Experience in performing Value Engineering studies with Charrette facilitation.

4. Experience in performing quantitative Cost and Schedule Risk Analyses on complex military facilities in accordance with DoD criteria.

Submission requirements:

Firms shall submit a maximum of seven (7) relevant design projects that best demonstrate specialized experience of the proposed team in the areas outlined above. Design must have been completed within the past seven (7) years immediately preceding the date of issuance of this notice. Sufficient information to determine the date of completion of the project must be included in the project description or the project will not be considered.

If more than the maximum number of projects is submitted, the Government will only evaluate projects up to the maximum number authorized in the order submitted.

All projects provided in the SF-330 must be completed by the actual office/branch/regional office/individual team member proposed to manage and perform work under this contract.

Projects not meeting this requirement will be excluded from consideration in the evaluation. To enable verification, firms should include the DUNS number along with each firm name in the SF-330 Part I, Section F, block 25, “Firm Name.” Include a contract number or project identification number in block 21. Include an e-mail address and phone number for the point of contact in block 23(c). In block 24, include in the project description the contract period of performance, award contract value, current contract value, and a summary of the work performed that demonstrates relevance to specialized experience as outlined above.

If a project was performed by a joint venture, and all joint venture partners are not on the team proposed for this contract, the firm/team should specifically address the work performed by the joint venture partner offering/teaming on this contract. Likewise, if the firm/team member worked as a subcontractor on a project, the description should clearly describe the work actually performed by the firm/team member and the roles and responsibilities of each on the project, rather than the work performed on the project as a whole. If the project description does not clearly delineate the work performed by the entity/entities offering/teaming on this contract, the project could be eliminated from consideration.

NOTE: If the offering firm is a joint venture, projects performed by the joint venture must be submitted; however, if there are no projects performed by the joint venture, at least one (1) design project must be submitted for each joint venture partner, not to exceed a total of seven (7) projects. Firms failing to provide projects from all joint venture partners will be considered to have not met the requirements of the criterion.

Projects shall be submitted on the SF-330 at Part I, Section F and shall be completed projects.

Projects not completed will be excluded from evaluation consideration. For submittal purposes, a task order on an IDIQ contract is considered a project, as is a stand-alone contract award. Do not submit an IDIQ contract as an example project. Instead, list relevant task orders or stand-alone contract awards that fit within the definition above. The Government will not evaluate information provided for an IDIQ contract. Examples of project work submitted that do not conform to this requirement will not be evaluated.

All information for Criterion 1 must be submitted in the SF-330, Part I, Section F. The Government WILL NOT consider any information submitted outside of Part I, Section F in evaluation of Criterion 1.

Criterion 2- Professional Qualifications and Technical Competence (SF-330, Part I, Sections E & G):

Firms will be evaluated on professional qualifications, competence, and experience of the proposed key personnel in providing services to accomplish the tasks required under this contract, including participation in example projects as outlined in the SF-330, Part I, Section G.

Key personnel are individuals who will have major contract or project management responsibilities and/or will provide unusual or unique expertise. Firms must include the following key personnel: Specific disciplines that must be included in key personnel are Cost Engineer (CCP or equivalent), Value Engineer (CVS or equivalent), Scheduler, Risk Analyst (CRA or Equivalent), Staff Economist, Architect, Civil Engineer, Structural Engineer, Mechanical Engineer, Electrical Engineer, Fire Protection Engineer, Geotechnical Engineer, Planner, and Interior Design.

Submission Requirements:

SF-330, Part I, Section E, provide resumes for all proposed key personnel that illustrate experience in the work proposed under this contract. Resumes are limited to one page each, single sided and must indicate: professional registration (including registration/certification number), certification, licensure and/or accreditation in appropriate disciplines; cite recent (within the past 7 years) project-specific experience in work relevant to the services required under this contract; and indicate proposed role in this contract. Indicate participation of key personnel in example projects in the SF-330, Part I, Section G.

Criterion 3- Past Performance (SF330, Part I, Section H):

Firms will be evaluated on past performance with Government agencies and private industry in terms of work quality, compliance with schedules, cost control, and stakeholder/customer satisfaction. Evaluating past performance and experience will include information provided in Past Performance Questionnaires (PPQs) or CPARS for Criterion 1 projects and may include customer inquiries, Government databases, and other information available to the Government, including contacts with points of contact in other criteria. NOTE: Past performance information for projects listed under Criterion 1 may be given greater weight.

Submission Requirements:

SUBMIT A COMPLETED CPARS EVALUATION FOR EACH PROJECT UNDER

CRITERION 1. IF A COMPLETED CPARS/ACASS EVALUATION IS NOT AVAILABLE,

the Past Performance Questionnaire (PPQ) (Attachment A) included in this notice is provided for the firm or its team members to submit to the client for each project included under Criterion 1, Specialized Experience. DO NOT SUBMIT A PPQ WHEN A COMPLETED CPARS/ACASS

IS AVAILABLE.

IF A CPARS EVALUATION IS NOT AVAILABLE, ensure correct phone numbers and email addresses are provided for the client point of contact. Completed PPQs must be submitted with your SF-330. If the firm is unable to obtain a completed PPQ from a client for a project(s) before the response date set forth in this notice, firms must complete and submit with their responses the first page of the PPQ (Attachment A), which will provide contract and client information for the respective project(s). Firms may submit a PPQ previously submitted under a different Notice/RFP (legible copies are acceptable) as long as it is on the same form as posted with this Synopsis. Firms should follow up with clients/references to ensure timely submittal of questionnaires. If requested by the client, questionnaires may be submitted directly to the Government's point of contact, Naval Facilities Engineering Systems Command Atlantic, Code CON22, Attn: Crystal Lopez via email at crystal.r.carter@navy.mil AND crystal.r.lopez8.civ@us.navy.mil, prior to the response date. Firms shall not incorporate by reference into their response PPQs or CPARS previously submitted in response to other A/E services procurements. However, this does not preclude the Government from utilizing previously submitted PPQ information in the past performance evaluation.

Firms may provide any information on problems encountered and the corrective actions taken on projects submitted under Criterion 1, Specialized Experience. Firms may also address any adverse past performance issues. Information shall not exceed two double-sided pages (or four single-sided pages) in total.

Awards, letters of commendation, certificates of appreciation, etc. shall not be submitted and will not be considered in the evaluation.

Criterion 4- Quality Control (SF330, Part I, Section H):

Firms will be evaluated on the strength of the quality control program proposed. Firms should demonstrate a means to ensure quality products and services under this contract, as well as quality services from their consultants/subcontractors.

Submission Requirements:

Describe the quality control program that will be utilized for all deliverables of this contract and the management approach for quality control processes and procedures. The description shall:

1. Explain the quality control program including an example of how the plan has worked for one of the projects submitted as part of SF-330, Section F or how the plan will work if it has not been used previously.

2. Provide a quality control process chart showing the inter-relationship of the management and team components.

3. Describe specific quality control processes and procedures proposed for this contract.

4. Identify the quality control manager and any other key personnel responsible for the quality control program and a description of their roles and responsibilities.

5. Describe how the firm’s quality control program extends to management of subcontractors.

Criterion 5- Program Management, Capacity and Location (SF330, Part I, Section H):

Firms will be evaluated on their ability to plan for and manage work under the contract, the capacity to accomplish the work in the required time, and on the locations of their office(s) that will be performing the work under this contract. Firms will also be evaluated on their demonstrated knowledge of the primary geographic areas in which projects could be located.

Submission Requirements:

1. Provide an organizational chart for the team and discuss the management plan for this contract and personnel roles in the organization. Describe the ability of the firm to manage, coordinate and work effectively with team members, both internal staff and consultants. Discuss the history of working relationships with team members, including joint venture partners where applicable.

2. Describe the firm’s present workload and the availability of the project team (including consultants) for the specified contract performance period. Describe the workload/availability of the key personnel during the anticipated contract performance period and the ability of the firm to provide qualified backup staffing for key personnel to ensure continuity of services. General statements of availability/capacity may be considered less favorably.

3. Provide the location of the office(s) that will be performing the work, including main offices, branch offices, and offices of team members. Evaluation of firms will include consideration of their location within the primary geographic area of the anticipated projects, primarily the United States, Europe, and Africa. Provide a narrative describing the team’s knowledge of the primary geographic areas in which projects could be located.

Criterion 6—Sustainable Design (SF330, Part I, Section H)

Firms will be evaluated in terms of their knowledge and demonstrated experience in applying sustainability concepts through an integral design approach, and designing in accordance with recognized sustainability rating systems such as Green Globe, LEED, etc.

Submission Requirements:

Identify examples indicating design team (including consultants) experience and concepts employed, certification awarded, and accredited professionals proposed for this contract. For projects certified, submit a copy of the certificate (certificates are not included toward the overall page count). Projects must have been completed within the past seven (7) years immediately preceding the date of issuance of this notice.

Criterion 7—Volume of Work (SF330, Part 1, Section H)

Firms will be evaluated in accordance with DOD Federal Acquisition Regulation Supplement (DFARS) Procedures, Guidance and Information (PGI) 236.602-1, Selection Criteria, from data extracted from the Federal Procurement Data System (FPDS). Firms will be evaluated in terms of work previously awarded to the firm by DOD within the past twelve months with the objective of effecting an equitable distribution of contracts among qualified A&E firms including small, disadvantaged business firms, and firms that have not had prior DOD A&E contracts.

Submission Requirements:

Firms do not submit data for this factor. The Government will obtain information as described above. For joint venture (JV) submissions, the Government will obtain the data for each JV partner.

SF-330 SUBMISSION REQUIREMENTS:

Architect-Engineer firms desiring to be considered for this contract must submit a completed SF- 330 package. The SF-330 must be typed, one sided, at least 11 point Times New Roman or larger. Do not submit information outside of what is required by the form. Part I shall not exceed seventy-five (75) single-sided 8.5 by 11 inch pages (the page limit does not include ISRs, certificates, PPQs, or licenses, nor does the page limit include cover sheets, dividers, or other requested documentation (e.g., joint venture agreement, proof of AE firm registration) provided that these do not contain any substantive information submitted in response to the synopsis or intended to demonstrate the qualifications of the firm). Part I pages shall be numbered sequentially. The organizational chart may be one page single sided 11 by 17 foldout, using 11 point font or larger (font limitations do not apply to graphics, captions or tables). Please include your DUNS and CAGE numbers in Block 30 of the SF-330.

FAILURE TO COMPLY WITH THE FOLLOWING REQUIREMENTS MAY RESULT

IN THE FIRM’S ELIMINATION FROM FURTHER EVALUATION:

1) In accordance with the FAR 36.601-4(b) contracts for architect-engineer services may only be awarded to firms permitted by law to practice the professions of architecture or engineering. Firms must submit proof that they are permitted by law as required by FAR 36.601-4(b). If a firm is in a jurisdiction that requires AE firm registration, the firm must provide proof of registration. If a firm is in a jurisdiction that does not require AE firm registration, the firm must provide proof eligibility to practice (e.g., state registration number or a brief explanation of the firm’s licensing in states that do not register firms, etc.) Failure to submit the required proof could result in a firm’s elimination from consideration.

2) Firms who are offering as a joint venture should include with their submission a copy of the joint venture agreement. Failure to include the joint venture agreement may result in the firm’s elimination from further evaluation.

Firms responding to this announcement by 19 October 2021, 1400 (EDT) will be considered. THIS IS NOT A REQUEST FOR PROPOSAL.

If an SF-254/SF-255 is submitted for this solicitation, it will not be reviewed or considered. As required above, provide verifiable evidence that your firm is permitted by law to practice the professions of architecture or engineering (e.g., state registration number).

Architect-Engineer firms that meet the requirements described in this announcement are invited to submit the SF-330 package via the DoD Secure Access File Exchange (SAFE) application. All responses to this announcement shall be submitted electronically via DoD SAFE. Hand carried delivery or postal/courier delivery of hard copies and/or CD-ROMs are not authorized. Facsimile submission is not authorized. All responses must be received by the Government by the response due date and time specified above. Instructions for response submission are as follows:

1. Send an email to both the Contract Specialist and Contracting Officer listed below at least 48 hours prior to the submission deadline, 15 October 2021, advising of the email address and point of contact that the firm will use to submit the SF-330 package.

Crystal Lopez, crystal.r.carter@navy.mil AND crystal.r.lopez8.civ@us.navy.mil

Rebecca Douglas, rebecca.douglas@navy.mil AND rebecca.v.douglas.civ@us.navy.mil

2. The Government will confirm receipt of the email and the Contracting Officer will send a “Request for drop-off” from the DoD SAFE application to the email provided by the firm.

3. The firm will then receive a “Request for drop off” email from the DoD SAFE application with a link provided to submit the response. Using the link provided, firms shall submit the complete SF-330 package. SF-330 packages must be submitted via the DoD SAFE application prior to the submission deadline. The Contracting Officer will confirm receipt.

Note that “Requests for drop-off” from the DoD SAFE application are only valid for 14 days.

The DoD SAFE application has a 25 file limit for upload and 8GB file size limit. Please plan accordingly. Do not assume that electronic submission will occur instantaneously. Large files may take some time to upload. Firms are encouraged to keep a copy of the upload confirmation for their record. Late responses will be handled in accordance with FAR 15.208.

Inquiries concerning this procurement should include solicitation number and title and be forwarded via email to Crystal Lopez at crystal.r.carter@navy.mil AND crystal.r.lopez8.civ@us.navy.mil. Questions will be accepted until Noon Eastern Time on 20 September 2021.

File details come from the government source that posted it. Updated .