N4523A18R1064_Attachment_J-3_RFC_005.pdf

PDF 156 KB Posted

Attached to
N4523A18R1064 UF-34 and UF-137
Solicitation number
N4523A18R1064
Issued by

About this file

Request for Clarification 005

View the file

Other files

File Type Posted
N4523A18R1064_Attachment_J-2b_UF-137_5-way_break_out_Updated_01JUNE2018.xls XLS spreadsheet
N4523A18R1064_Attachment_J-1a_UF-34_Updated_SOW_Errata_1_01JUNE2018.pdf PDF
N4523A18R1064_Attachment_J-3_RFC_002.pdf PDF
N4523A18R1064_Attachment_J-3_RFC_001.pdf PDF
N4523A18R1064_Attachment_J-2a_UF-34_5-way_break_out_Updated_01JUNE2018.xls XLS spreadsheet
N4523A18R1064_Attachment_J-3_RFC_004.pdf PDF
N4523A18R1064_Attachment_J-3_RFC_003.pdf PDF
N4523A18R1064_Attachment_J-1b_UF-137_Updated_SOW_Errata_1_01JUNE2018.pdf PDF
N4523A18R1064_Attachment_J-7_BAVR_Instructions.pdf PDF
N4523A18R1064_UF-34_and_UF-137_Solicitation.pdf PDF
N4523A18R1064_Attachment_J-2a_UF-34_5-way_break_out.xls XLS spreadsheet
N4523A18R1064_Attachment_J-2b_UF-137_5-way_break_out.xls XLS spreadsheet
N4523A18R1064_Attachment_J-1a_UF-34_SOW.pdf PDF
N4523A18R1064_Attachment_J-1b_UF-137_SOW.pdf PDF
N4523A18R1064_Attachment_J-6b_UF-137_SOW_references_.zip ZIP file
N4523A18R1064_Attachment_J-5_Corporate_Experience_Data_Sheet.docx DOCX document
N4523A18R1064_Attachment_J-6a_UF-34_SOW_references_.zip ZIP file
N4523A18R1064_Exhibit-A_CDRLs_and_DIDs.zip ZIP file
N4523A18R1064_Attachment_J-4_Contract_Performance_Data_Sheet.docx DOCX document
N4523A18R1064_Attachment_J-3_Request_for_Clarification_(RFC)_Form.docx DOCX document
N4523A18R1064_UF-137_SOW_Draft.pdf PDF
N4523A18R1064_UF-34_SOW_Draft.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR SPECIFICATION CLARIFICATION

DATE OF REQUEST: IJUN2018 QUESTION NO: 005

REQUIREMENT: N/A REQUISITION NO.: N4523A18R1064

ITEM NO: N/A

TITLE: 5-WAY BREAKDOWN SHEET

ISSUING OFFICE POC (CODE 440.22):

Brittany Chartier: (360) 476-5708

Brittany.chartier@navy.mil

PARA. NO: 3.3.1 PAGE NO: 27, SOW CONTRACTOR:

PLANNER’S NAME: ATTACH. NO: CONTRACTOR POC & PHONE:

CONTRACTOR QUESTION: UF-137

1. THE 5-WAY BREAKDOWN DOES NOT REFLECT REPAIRS FOR PARA 3.3.1. IS THE

CONTRACTOR NOT TO BID THIS PARAGRAPH?

DO NOT WRITE BELOW THIS LINE

SPEC CHG: Y/N DWG/REF CHG. Y/N RQMTS CHG: Y/N MAT'L CHG: Y/N

TECHNICAL REVIEW: SERIAL NO:

Please see the updated 5 way break out (Attachment J-2b) dated 01JUNE2018 posted on FBO.gov under solicitation N4523A18R1064.

ALL REQUESTS FOR CLARIFICATION MUST BE RECEIVED BY THE ISSUING OFFICE POC NO

LATER THAN THE DATE & TIME IDENTIFIED IN THE REQUEST FOR PROPOSAL.