N4215822RC20683
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
This Amendment is for the follow ing:
1. Remove ECMRA Language from Statement of Work
2. Add FAR Clause 52.209-10 Prohibition on Contracting w ith Inverted Domestic Corporations.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 5
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 22-Jul-2022
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X N4215822Q0016
X 9B. DATED (SEE ITEM 11)
18-Jul-2022
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
22-Jul-2022
CODE
NORFOLK NAVAL SHIPYARD
ATTN: TINA JAUREQUI
CVN SUPPORT BRANCH
C432, BLDG 65, 2ND FLOOR
PORTSMOUTH VA 23709-1022
N42158 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
N4215822Q0016
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by reference:
52.209-10 Prohibition on Contracting With Inverted Domestic
Corporations
NOV 2015
SECTION SF 1449 - CONTINUATION SHEET
The following have been modified:
STATEMENT OF WORK
1. Scope:
1.1 Title: Temporary JP-5 Equipment-Sponson Connection
1.2 Job Order: 3875E99218 S03
1.3 Location of work:
1.3.1 Inside NNSY waterfront CIA.
2. Reference:
2.1 OPNAVINST 5100.23G
3. General Specifications:
3.1 Rental of one (1) diesel powered pump for JP-5 pumping with the following specifications:
3.1.1 Pump must be diesel powered.
3.1.2 Pump must provide 150 GPM (minimum) at 50 PSIG discharge pressure. Limit RPM of motor is 1500 RPM (maximum).
3.1.3 Pump must be able to prime automatically and quickly for suction lifts of up to 28 feet without use of foot valves.
3.1.4 Pump must have a 40-gallon (minimum) diesel fuel tank.
3.1.5 Pump must be a separate compact unit mounted on a trailer type chassis with integral fuel tank. The total weight including all fluids must be stenciled on the unit with minimum 1” high letters.
3.1.6 Pump must be capable of continuous operation. Normal duty for pump will be to supply JP-5 fuel to ship tanks in an emergency.
3.1.7 Maximum working pressure of pump unit shall be 50 PSIG.
3.1.8 Hose connections: 3” suction and 2” discharge (Camlok).
3.1.9 Pump unit shall have discharge pressure gage (0 – 100 PSIG minimum range).
3.1.10 Pump unit shall have winterization features such as water jacket heaters and lube oil sump heaters to ensure rapid starting during freezing conditions.
3.1.11 Pump and associated equipment shall be free of leaks, cracks, etc.
3.1.12 Pump shall be operationally tested prior to delivering to NNSY. Pump shall be cleaned and dry for JP-5 fuel service.
3.1.13 Provide one 3” suction hose 20’ length with male/female Camlok end fittings suitable for JP-5 fuel service. Hose assembly shall be free of leaks, cracks, chaffing, cuts, rips, tears, and any other damage. It shall be pressure tested and cleaned for JP-5 fuel service. Hose ends shall be blanked/capped to prevent debris from entering hose.
4. Contractor Requirements:
4.1 Maintenance/Monthly Checks/Training
4.1.1 Provide POC information (name and phone number) on the equipment.
4.1.2 Upon arrival to NNSY for pump delivery, Contractor shall contact Temporary Service
Zone Manager (TSZM) for information regarding placement of the pump at NNSY job site.
4.1.3 Deliver and place JP-5 pump at NNSY job site. (Exact location to be determined at delivery.)
4.1.4 Visit NNSY pump installation site monthly and perform necessary preventative and corrective maintenance and visual checks (fluid levels, system leaks, gauge, and battery) at no additional charge.
4.1.5 Contractor personnel shall contact the Temporary Service Zone Manager (TSZM) for authorization prior to any work or maintenance on rental unit.
4.1.6 Provide training and written instructions for shipyard operators on the proper operation and the performance of basic monitoring and visual checks of the pump.
4.1.7 Contractor will not operate equipment.
4.1.8 JP-5 pump and trailer will be located in an area where they will be exposed to everyday weather and seawater mist. It is the contractor’s responsibility to provide any protective coverings.
4.1.9 The contractor shall dispatch a representative in response to a service request to repair and / or replace the JP-5 pump, hoses or fuel tank within 24 hours of notification by NNSY at no additional charge.
4.1.10 When the equipment is required to be removed to the contractor’s facility for repair or replacement, the contractor shall be responsible for loss or damage from the time it leaves the Government Site until it is returned to the Government.
4.1.11 Contractor must submit a claim separate from rental, for lost items by Government personnel or equipment damaged beyond normal wear and tear. This is to be submitted no later than 60 days past the end of the rental period.
4.1.12 Contractor to provide options to allow NNSY to extend rental of JP-5 pump on a monthly basis. The Government reserves the right to extend the rental period on a monthly basis if necessary. The Government reserves the right to return the unit at any time prior to the expiration of rental period. The contractor agrees to prorate costs for the time the JP-5 pump in use by NNSY only.
4.1.13 The Government agrees to give the contractor twenty-four (24) hours-notice for the return of the JP-5 pump and equipment if the return is prior to the expiration of rental period.
4.1.14 Contractor to contact NNSY 10 business days prior to the end of rental period to confirm pickup date.
4.1.15 Contractor will relocate tanker trailer from dockside to pier side when ship is undocked.
5. Government Responsibility:
5.1 Provide operators for equipment.
5.1.1 Perform basic monitoring/visual checks outside of the monthly site visits by the contractor:
a) Monitor oil/fuel levels.
b) Monitor all fluid levels (diesel engine and pump).
c) Monitor all gauges.
5.1.2 Provide diesel fuel to support pump operation.
5.1.3 Equipment movements.
5.1.4 Provide point of contact for delivery, escort and notification to contractor for rental pickup. (Temporary Service Zone Manager.)
6. Points Of Contact:
6.1 Technical POC: TBA UPON AWARD
Invoice Certifying / Temporary Service Zone Manager (TSZM): TBA UPON AWARD
7. Safety Requirements:
7.1 " Per FAR 22.102-1(a) entitled "Safety", Contractors are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard cognizance must follow Federal and State OSHA requirements OSHE OSHECM Chapter Hazardous Energy Control (HEC) requirements or safety requirements for site specific location of the contract.
a. Contractors and Non-NNSY Government Agencies (NNGAs) are hereby informed that their employees or representatives present on property under Norfolk Naval Shipyard (NNSY) cognizance must adhere to Federal OSHA requirements for hazardous energy control IAW 29 CFR 1915.89 and must follow Hazardous Energy Control (HEC) procedures as identified in NAVSEA’s Occupational Safety, Health, and Environment Corporate Manual (OSHECM) Chapter 250 (latest revision), when performing work under NNSY contract. All HEC work to be performed by Contractors and NNGAs requires that NNSY Technical Points of Contact (TPOCs) and/or Contracting Officer’s Representatives (CORs) be notified of the HEC scope of work prior to starting work. Any changes or deviations in the initial scope of HEC work requires the NNSY TPOCs and/or CORs be informed of the change/deviation. Appendix 250.B- 1 through B-3 of OSHECM Chapter 250 for multiple employer work identifies when Contractors and NNGAs are required to assign their Lockout/Tags-Plus Coordinator (LOTC) to coordinate HEC work with the cognizant NNSY LOTC. HEC locks shall be provided by the contractor or NNGA for their employees use. The HEC locks shall have red bodies with name labels or name tags affixed, identifying who installed the HEC lock(s) and a point of contact telephone number. HEC lock name labels and tags must be made of materials that will hold up to the environment to which they are exposed. HEC tags used for Tags-Plus HEC work shall be provided by the cognizant NNSY LOTC to the contractor or NNGA for their use if machinery, equipment, or systems (MES) cannot be locked out. OSHECM Chapter 250 Tags-Plus procedures will be strictly followed.
b. Contractors and NNGAs may obtain electronic copies of OSHECM Chapter 250 (latest revision) and access the OSHA 1915.89 web site by using the following link to NNSY’s public access web site: http://www.navsea.navy.mil/shipyards/norfolk/default.aspx
c. Names and contact information for NNSY LOTCs and/or the Building Monitor will be provided by NNSY TPOC and/or contracting officer representatives (COR) set forth elsewhere in this award document.
8. DBIDS
Identification Badges and Installation Access.
• Any new contractor, vendor or supplier requesting base access AFTER 31 May 2017 will be required to obtain a DBIDS credential. NCACS credentials will no longer be issued.
• Only DBIDS credentials will be issued to ALL contractors, vendors and suppliers seeking base access AFTER 14 August 2017.
Defense Biometric Identification System (DBIDS) increases installation security and communications by receiving frequent database updates on changes to personnel/credential status, law enforcement warrants, lost/stolen cards, and force protection conditions. The system provides a continuous vetting anytime the DBIDS card is scanned at an installation entry point.
If you currently have a Navy Commercial Access Control System (NCACS) card, the following is required to get a DBIDS credential:
• Present your NCACS Card and a completed copy of the SECNAV FORM 5512/1 to the base Visitor Control Center representative.
• The VCC will pull up your information in the computer, ensuring all information is current and correct.
• Once your information is validated, a temporary DBIDS credential is provided.
• Your temporary credential will have an expiration date, prior to which you will need to obtain your permanent DBIDS credential (~ 90 days).
• For each additional U.S. Navy installation to which you need access, the first time you visit you only need to bring your DBIDS credential and statement of purpose for base access when arriving at the Visitor Control Center.
• The representative will enter base access authorization and then you may proceed to work.
If you do NOT have an NCACS Card, the following is required to obtain a DBIDS credential:
• Present a letter or official document from my government sponsoring organization that provides the purpose for your access.
• Present valid identification, such as a passport or Real ID Act-compliant state driver's license.
• Present a completed copy of the SECNAV 5512/1 form to obtain your background check.
• Upon completion of the background check, the Visitor Control Center representative will complete the DBIDS enrollment process, which includes your photo, finger prints, base restrictions, and several other assessments; after all this is done, you will be provided with your new DBIDS credential.
• You may now proceed to work.
FOR ADDITIONAL QUESTIONS ABOUT OBTAINING A DBIDS CARD, CONTACT YOUR LOCAL BASE
VISITOR CONTROL CENTER. INFORMATION IS ALSO PROVIDED AT: www.cnic.navy.mil/om/dbids.html
1.2. One-Day Passes. Participation in the DBIDS is not mandatory, and if the Contractor chooses to not participate, the Contractor's personnel will have to obtain daily passes, be subject to daily mandatory vehicle inspection, and will have limited access to the installation. The Government will not be responsible for any cost or lost time associated with obtaining daily passes or added vehicle inspections incurred by non-participants in the DBIDS.
PORTABLE ELECTRONIC DEVICES (PEDs) In accordance with COMSUBLANT/COMSUBPACINST 2075.1C, the use of Portable Electronic Devices (PEDs) while in or on Department of Navy Submarine spaces are prohibited. A portable electronic device (PED) is defined as any non-stationary electronic apparatus with singular or multiple capabilities of, but not limited to recording, storing, and/or transmitting data, voice, video, or photo images (e.g., cell phones, laptops, tablets and wearable devices such as fitness bands and smart watches).
(End of Summary of Changes)
File details come from the government source that posted it. Updated .