7328487 DwgsAsOne - SIGNED.pdf

PDF 17 MB Posted

Attached to
Provide Prohibited/Restricted Signs at Range and Training Areas BT11 & BT09
Solicitation number
N400857328487
Issued by

About this file

This document is a Request for Proposal (RFP) for a contract to provide prohibited/restricted signs at range and training areas BT11 and BT09. The procurement is restricted to the General MACC contractors listed on the RFP cover letter. The Department of the Navy Naval Facilities Engineering Command is the issuing agency. The RFP includes the scope of work and any applicable drawings. No additional details are provided in the document provided.

View the file

Other files

File Type Posted
AMENDMENT 0006.pdf PDF
AMENDMENT 0005.pdf PDF
AMENDMENT 0004.pdf PDF
AMENDMENT 0003.pdf PDF
AMENDMENT 0002.pdf PDF
AMENDMENT 0001.pdf PDF
RFP 7328487.pdf PDF
7328487 SpecsAsOne - SIGNED.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MCB CAMP LEJEUNE

FRANKLIN

BLADEN

WAYNE

JOHNSTON

WILSON

NASH

EDGECOMBE

SAMPSON

DUPLIN

JONES

GREENE

LENOIR

PITT

CARTERET

CRAVEN

ONSLOW

PENDER

PAMLICO

BEAUFORT

HYDE

DARE

TAN K

TYRRELL

UI M

ANS

H O W

A N

MARTIN WASHINGTON

BERTIE

HALIFAX

MCAS CHERRY POINT

MCAS CHERRY POINT

BOMBING RANGE SITES

INDEX OF DRAWINGS

GENERAL

SHEET NAME NAVFAC DRAWING NO. PAGE SHEET DESCRIPTION

G-001 12891946 1 COVER SHEET

CIVIL

SHEET NAME NAVFAC DRAWING NO. PAGE SHEET DESCRIPTION

C-001 12891947 2 SHEET INDEX, CIVIL GENERAL NOTES, LEGENDS AND ABBREVIATIONS

C-002 12891948 3 OVERALL SITE INDEX

C-100 12891949 4 BOMBING RANGE BT-11 OVERALL PLAN

C-101 12891950 5 BOMBING RANGE BT-11

C-200 12891951 6 BOMBING RANGE RACCOON ISLAND

C-300 12891952 7 BOMBING RANGE MAW POINT

C-400 12891953 8 BOMBING RANGE BT-09 OVERALL PLAN

C-401 12891954 9 BOMBING RANGE BT-09

C-402 12891955 10 BOMBING RANGE BT-09

C-403 12891956 11 BOMBING RANGE BT-09

C-500 12891957 12 BOMBING RANGE PAMLICO POINT

C-600 12891958 13 CIVIL DETAILS

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA ININ

G

MCAS CHERRY POINT, NC

FINAL - 03-01-2024

7328487

VICINITY MAP - MCAS CHERRY POINT, N.C.

C O

V E

R S

H E

E T

12891946

G-001

PROVIDE PROHIBITED/RESTRICTED SIGNS

AT RANGE AND TRAINING AREAS

WO# 7328487

MARINE CORPS AIR STATION

CHERRY POINT, NORTH CAROLINA

FINAL DESIGN

RACCOON ISLAND

BT-11

PAMLICO SOUND

AT

LA

NT

IC

O

CE

AN

MCAS CHERRY POINT

BT-9

PAMLICO POINT

MAW POINT

NEUSE RIVER

MCAS CHERRY POINT - STATION MAPSCALE: 1" = 15000'

ORIENTAL

ARAPAHOE

GRANTSBORO

HOBUCKEN

STONEWALL

HAVELOCK

HARLOWE

NEWPORT

NEW BERN

MERRIMON

NOT TO SCALE

3/8/2024

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

NORTH

1. REFER TO THE PROJECT SPECIFICATIONS IN ALL

SITUATIONS. BRING CONFLICTS BETWEEN PROJECT

SPECIFICATIONS AND PLANS TO THE ATTENTION OF THE

CONTRACTING OFFICER AND/OR ENGINEER FOR

RESOLUTION. ALL MATERIALS AND WORKMANSHIP MUST

CONFORM TO THE PROJECT SPECIFICATIONS.

2. EXISTING UTILITY INFORMATION IS NOT TO BE RELIED

ON AS BEING EXACT OR COMPLETE. LOCATION,

VERIFICATION, SUPPORT AND PROTECTION OF ALL

ABOVE GROUND AND UNDERGROUND UTILITIES TO

REMAIN IN PLACE, INCLUDING ANY UTILITIES NOT

INDICATED ON CONTRACT DRAWINGS IS REQUIRED. ANY

CONFLICTS OR DISCREPANCIES MUST BE BROUGHT TO

THE CONTRACTING OFFICER'S AND/OR ENGINEER'S

ATTENTION IMMEDIATELY. CAPE FEAR ENGINEERING

HAS NOT PHYSICALLY LOCATED ANY UNDERGROUND

UTILITIES.

3. PRIOR TO ANY EXCAVATION, CONTRACTOR MUST HAVE

THE EXISTING UNDERGROUND LINES MARKED ON THE

GROUND SURFACE IN THE AREAS OF CONSTRUCTION.

POTHOLE AND PHYSICALLY VERIFY DEPTH AND

LOCATION OF ALL UTILITY LINES IN THE WORK AREA

THAT REQUIRE COORDINATION WITH WORK ITEMS.

POTHOLE VERIFICATION MUST BE DONE WELL IN

ADVANCE OF ACTUAL WORK SO THAT POTENTIAL

UTILITY CONFLICTS CAN BE VERIFIED AND RESOLVED

WITHOUT CAUSING SCHEDULE DELAYS.

4. PROTECT ALL EXISTING STRUCTURES, TREES,

PAVEMENT, UTILITIES, AND OTHER PROPERTY UNLESS

THEY ARE TO BE DEMOLISHED. ANY PROPERTY NOT

AUTHORIZED FOR REMOVAL, BUT DAMAGED BY THE

CONTRACTOR MUST BE RESTORED BY THE

CONTRACTOR TO THEIR PRE-CONSTRUCTION

CONDITION OR BETTER AT NO ADDITIONAL EXPENSE TO

THE OWNER.

5. MAKE EVERY EFFORT TO SAVE PROPERTY IRONS,

MONUMENTS, OTHER PERMANENT POINTS AND LINES

OF REFERENCE AND CONSTRUCTION STAKES.

PROPERTY IRONS, MONUMENTS, AND OTHER

PERMANENT POINTS OF REFERENCE DESTROYED BY

THE CONTRACTOR MUST BE REPLACED AT THE

CONTRACTOR'S EXPENSE.

6. WORK PERFORMED UNDER THIS CONTRACT MUST NOT

IMPACT THE OPERATION OF ANY ADJACENT

PROPERTIES UNLESS A UTILITY OUTAGE HAS BEEN

APPROVED IN ADVANCE.

7. CONTRACTOR IS RESPONSIBLE FOR ALL SURVEYING

AND STAKING TO COMPLETE THE WORK.

8. ANY AND ALL MATERIAL QUANTITIES INDICATED ON THIS

PLAN SET ARE FOR REFERENCE ONLY. CONTRACTOR

MUST VERIFY ALL MATERIAL QUANTITIES SHOWN.

9. KEEP REDLINE MARK-UPS OF ANY CHANGES MADE

FROM THE APPROVED PLAN AND PROVIDE COPY OF

REDLINES TO ENGINEER UPON PROJECT COMPLETION.

ABBREVIATIONS

A/C AIR CONDITIONER

ATFP ANTI TERRORISM FORCE PROTECTION

BFF BELOW FINISHED FLOOR

BLDG BUILDING

BMP BEST MANAGEMENT PRACTICE

BW BARBED WIRE

C&G CURB AND GUTTER

CB CATCH BASIN

CC CONCRETE CURB

CI CURB DROP INLET

CJ CONTRACTION JOINT

CLF CHAIN LINK FENCE

CMH COMMUNICATION MANHOLE

CONC CONCRETE

D/B DESIGN/BUILD

DCJ DOWELED CONSTRUCTION JOINT

DI DROP INLET

DPW DEPARTMENT OF PUBLIC WORKS

DUMP DUMPSTER

E EAST

EHH ELECTRICAL HANDHOLE

EG EXISTING GAS

EJ EXPANSION JOINT

ELEC ELECTRIC

EMH ELECTRICAL MANHOLE

EL ELEVATION

FDC FIRE DEPARTMENT CONNECTION

FES FLARED END SECTION

FFE FINISH FLOOR ELEVATION

FL FLOW LINE

GFGI GOVERNMENT FURNISHED, GOVERNMENT INSTALLED

HW HEAD WALL

IE INVERT ELEVATION

LP LIGHT POLE

LSA LANDSCAPE STONE

MAT MATERIAL

MH MANHOLE

MOF METAL ORNAMENTAL FENCE

MUTCD MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES

N NORTH

NCDEQ NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY

NCDOT NORTH CAROLINA DIVISION OF TRANSPORTATION

NE NORTHEAST

NIC NOT IN CONTRACT

NOAA NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION

NW NORTHWEST

PNG PIEDMONT NATURAL GAS

PP POWER POLE

PT PHYSICAL TRAINING

PVC POLYVINYL CHLORIDE

RCP REINFORCED CONCRETE PIPE

S SOUTH

SCM STORMWATER CONTROL MEASURE

SDMH STORM DRAIN MANHOLE

SE SOUTHEAST

SEP SEPARATION

SSMH SANITARY SEWER MANHOLE

STA STATION

STY STORY

SW SOUTHWEST

TC TOP OF CURB

TD TRENCH DRAIN

TE THICKENED EDGE

TEJ THICKENED EDGE EXPANSION JOINT

THH TELECOMMUNICATION HANDHOLE

TMH TELECOMMUNICATION MANHOLE

TRANS TRANSFORMER

TSB TEMPORARY SEDIMENT BASIN

TYP TYPICAL

UG UNDERGROUND

UNK UNKNOWN

W WEST

W/BW WITH BARBED WIRE

WV WATER VALVE

WW WING WALL

Ø DIAMETER

NGVD NATIONAL GEODETIC VERTICAL DATUM

MHW MEAN HIGH WATER LINE

MLW MEAN LOW WATER LINE

SYMBOL LEGEND:

DETAIL/VIEW

REFERENCE

SECTION

DETAIL TITLE

NOT TO SCALE

VIEW TITLE

DETAIL TITLE

IDENTIFICATION NUMBER

SHEET # FOR

SECTION/DETAIL

SCALE

IDENTIFICATION

NUMBER

IDENTIFICATION NUMBER

SHEET # FOR

SECTION/DETAIL

C-500

A1

C-500

SCALE

VIEW TITLE

1" = 20'

PLAN

NORTH

CIVIL GENERAL NOTES:

PRECAUTION:

NOTE THE FOLLOWING:

A. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDNANCE (UXO) MAY BE PRESENT. CONTRACTOR'S

REQUIRED UXO TECHNICIAN MUST CONDUCT A

SUBSURFACE SURVEY (I.E., WITH GROUND

PENETRATING RADAR OR OTHER TECHNICALLY

ACCEPTED PRACTICE) TO DETECT ANY PRESENCE OF

UXO. IF UXO IS LOCATED, SIGNS WILL BE RELOCATED

FROM THE POTENTIAL UXO AREA TO A DISTANCE THAT

IS DETERMINED BY THE UXO TECHNICIAN TO BE SAFE

FROM ALL GROUND DISTURBING ACTIVITY ASSOCIATED

WITH SIGN SUPPORT / PILE/ PYLON INSTALLATION.

B. COMMUNICATIONS WITH RANGE OPERATIONS ARE

REQUIRED FOR SEQUENCING AND SCHEDULING

PORTIONS OF THE WORK. PROTOCOL INCLUDING WHEN

COMMUNICATIONS ARE REQUIRED AND USE OF

MARITIME VHF CHANNEL 83A, CALENDAR OF ANY

RANGE ACTIVITIES AND OTHER SPECIFICS WILL BE

PROVIDED AT PRECONSTRUCTION MEETING. S

H E

E T

IN

D

E X

, C

IV

IL

G

E N

E R

A L

N O

TE

S

, L E

G E

N D

S , A

N D

A B

B R

E V

IA

TI

O N

S

12891947

C-001

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

PARCEL BOUNDARY LINE

EXISTING OPEN WATER PILING

(REFERENCE ONLY)

EXISTING OPEN WATER PILING WITH

NEW SIGN(S)

NEW OPEN WATER PILING

NEW LAND SIGN

LEGEND:

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot joness Snapshot

O V

E R

A

LL

S

IT

E

IN

D E

X

12891948

C-002

1 OVERALL SITE INDEX

SCALE: 1" = 7000'

PLAN

NORTH

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

SCALE: 1"=7000'

3500' 7000' 14000' 21000'0

RACCOON ISLAND

SEE SHEET C-200

BT-11

SEE SHEETS

C-100 & C-101

BT-9

SEE SHEETS

C-400, C-401, C-402 & C-403

PAMLICO POINT

SEE SHEET C-500

MAW POINT

SEE SHEET C-300

PAMLICO SOUND

ATLA

NTIC

O

CEAN

ORIENTAL

MERRITT

MERRIMON

NEUSE RIVER

BAY RIVER

BAYBORO

VANDEMERE

CEDAR ISLAND

WEST BAY

HOBUCKEN

LOWLAND

PAMLICO SOUND

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

C-101

C-101

C-101

C-101

C-101

B O

M B

IN

G

R A

N G

E B

T-

O V

E R

A

LL

P

LA

N

12891949

C-100

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

73284871 BOMBING RANGE BT-11 OVERALL PLAN

SCALE: 1" = 2500'

PLAN

NORTH

SCALE: 1"=2500'

2500' 5000' 7500'0

NEW STUMP POINT

JACKS BAY

RATTAN SPIT

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

1. SEE SHEET C-001 FOR SHEET INDEX, CIVIL GENERAL

NOTES, LEGENDS, AND ABBREVIATIONS.

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND

SIGN #2 (LASER WARNING) ON EXISTING PILING

1 2 3 4

BOMBING RANGE BT-11

SIGN

NUMBER

NORTHING

492568.67 488696.56 477594.55 472615.06 456893.93 455538.54

EASTING

2754938.97 2753785.28 2770403.76 2769311.65 2770367.97 2769419.21

SUMMARY OF WORK

INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING INSTALL SIGN #1 (DANGER - BOMBING RANGE) AND SIGN #2 (LASER WARNING) ON EXISTING PILING

B O

M B

IN

G

R A

N G

E B

T-

12891950

C-101

TYP

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

TYP

1 BOMBING RANGE BT-11

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

BOMBING RANGE BT-11 BOMBING RANGE BT-11 BOMBING RANGE BT-11

BOMBING RANGE BT-11

C-600 7 1

TYP

C-600

TYP

C-600

TYP

TYP

6 BOMBING RANGE BT-11 COORDINATE TABLE

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

C-600

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

1. SEE SHEET C-001 FOR SHEET INDEX, CIVIL GENERAL

NOTES, LEGENDS, AND ABBREVIATIONS.

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

BOMBING RANGE RACCON ISLAND

SIGN

NUMBER NORTHING EASTING SUMMARY OF WORK

1 40663.9200 230707.0200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

2 40673.5500 230678.1600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

3 40709.7600 230661.6400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

4 40727.3900 230627.0500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

5 40736.0100 230591.3200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

6 40776.2500 230586.5700

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

7 40812.8600 230590.9300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

8 40851.6200 230588.5800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

9 40885.8300 230572.6300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

10 40920.5300 230583.9300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

11 40948.8400 230582.5800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

12 40935.8300 230616.0700

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

13 40920.6200 230650.8700

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

14 40882.7800 230659.1400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

15 40850.7500 230677.8700

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

16 40823.5200 230707.9200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

17 40811.1100 230746.6100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

18 40790.4700 230781.8500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

19 40773.5100 230817.0100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

20 40754.9900 230837.8800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

21 40732.8500 230796.0400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

22 40717.7900 230761.2000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

23 40685.4400 230737.6400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

1. INSTALL SIGN #5 (UNEXPLODED ORDINANCE - DO

NOT ENTER) ON NEW LAND MOUNTED POST

B O

M B

IN

G

R A

N G

E R

A C

C O

O N

IS

LA

N D

12891951

C-200

1 BOMBING RANGE RACCOON ISLAND

PLAN

NORTH

SCALE: 1" = 500'

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

SCALE: 1"=500'

250' 500' 1000' 1500'0 2 BOMBING RANGE RACCOON ISLAND COORDINATE TABLE

TYP

C-600

C-600

NOTE: COORDINATES PROVIDED BY MCAS CHERRY POINT

FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR

ADJUSTING SIGN LOCATIONS AS INDICATED ON DETAILS. ALL

SIGNS TO BE LOCATED "ON-LAND". AFTER INSTALLATION,

CONTRACTOR TO AS-BUILT SURVEY LOCATIONS AND

PROVIDE UPDATED COORDINATES.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

1. SEE SHEET C-001 FOR SHEET INDEX, CIVIL GENERAL

NOTES, LEGENDS, AND ABBREVIATIONS.

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL SIGN #5 (UNEXPLODED ORDINANCE - DO

NOT ENTER) ON NEW LAND MOUNTED POST

BOMBING RANGE MAW POINT

SIGN

NUMBER NORTHING EASTING SUMMARY OF WORK

1 43219.6800 228009.6200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

2 43185.7000 227996.1300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

3 43180.6600 227959.3000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

4 43159.4300 227942.8100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

5 43163.2500 227906.5500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

6 43166.0500 227886.6500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

7 43144.0400 227867.2400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

8 43136.5500 227835.9900

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

9 43120.2800 227825.0100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

10 43151.7600 227798.7300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

11 43170.4000 227816.8400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

12 43181.5100 227844.0100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

13 43205.6200 227856.5500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

14 43234.3500 227866.4400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

15 43259.8700 227870.8600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

16 43284.9400 227888.1500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

17 43277.2100 227910.5400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

18 43290.7400 227945.6800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

19 43323.2700 227941.9600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

20 43358.8400 227944.4800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

21 43331.1600 227964.1400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

22 43293.1400 227977.5000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

23 43263.3000 228001.1900

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

24 43228.6800 228011.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

B O

M B

IN

G

R A

N G

E M

A W

P O

IN

T

12891952

C-300

1 BOMBING RANGE MAW POINT

PLAN

NORTH

SCALE: 1" = 500'

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

SCALE: 1"=500'

250' 500' 1000' 1500'0 2 BOMBING RANGE MAW POINT COORDINATE TABLE

C-600 5 1

TYP

C-600

NOTE: COORDINATES PROVIDED BY MCAS CHERRY POINT

FOR REFERENCE ONLY. CONTRACTOR RESPONSIBLE FOR

ADJUSTING SIGN LOCATIIONS AS INDICATED ON DETAILS.

ALL SIGNS TO BE LOCATED "ON-LAND". AFTER INSTALLATION,

CONTRACTOR TO AS-BUILT SURVEY LOCATIONS AND

PROVIDE UPDATED COORDINATES.

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

C-401

C-401

C-402

C-402

C-402

C-402

C-402

C-402

C-402

C-402

C-402

C-402

C-402

C-403

C-403

C-403

C-403

C-403

C-401

C-401

C-401

C-401

C-401

5 C-401

C-401

C-401

C-402

C-401

C-401

C-403

B O

M B

IN

G

R A

N G

E B

T-

O V

E R

A

LL

P

LA

N

12891953

C-400

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

73284871 BOMBING RANGE BT-09 OVERALL PLAN

SCALE: 1" = 2500'

PLAN

NORTH

SCALE: 1"=2500'

2500' 5000' 7500'0

FOR REFERENCE ONLY

SIGNS TO BE REPLACED

NEW SIGNS & PILES TO

BE INSTALLED

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

A

NOTES, LEGENDS, AND ABBREVIATIONS.

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL NEW OPEN WATER PILING WITH SIGN #1

(DANGER - BOMBING RANGE) AND SIGN #2 (LASER

WARNING).

2. REMOVE EXISTING "DANGER" SIGN AND INSTALL

NEW SIGN #1 (DANGER - BOMBING RANGE) ON

EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

3. INSTALL NEW SIGN #1 (DANGER - BOMBING RANGE(

ON EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

4. NO WORK INCLUDED FOR REFERENCE ONLY.

B C D

E F G H

I J K L

B O

M B

IN

G

R A

N G

E B

T-

12891954

C-401

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

1 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

TYP

2 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

3 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

4 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

C-600

3 2

TYP

5 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

6 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

7 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

8 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 4 1

TYP

C-600

9 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 4 1

TYP

C-600

10 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 2

TYP

11 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 4 1

TYP

C-600

12 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 2

TYP

C-600

C-600

C-600

SEE FOR COORDINATE TABLEC-403

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL NEW OPEN WATER PILING WITH SIGN #1

(DANGER - BOMBING RANGE) AND SIGN #2 (LASER

WARNING).

2. REMOVE EXISTING "DANGER" SIGN AND INSTALL

NEW SIGN #1 (DANGER - BOMBING RANGE) ON

EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

3. INSTALL NEW SIGN #1 (DANGER - BOMBING RANGE(

ON EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

4. NO WORK INCLUDED FOR REFERENCE ONLY.

M

R S T

U XW

N O P

Q

V

B O

M B

IN

G

R A

N G

E B

T-

12891955

C-402

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

1 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

C-600

3 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

4 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

5 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

C-600

3 2

TYP

C-600 3 3

TYP

6 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

7 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

8 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

9 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

C-600

3 3

TYP

C-600

3 3

TYP

C-600 3 3

TYP

11 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

C-600

3 3

TYP

12 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

2 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

10 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 2

TYP

SEE FOR COORDINATE TABLEC-403

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL NEW OPEN WATER PILING WITH SIGN #1

(DANGER - BOMBING RANGE) AND SIGN #2 (LASER

WARNING).

2. REMOVE EXISTING "DANGER" SIGN AND INSTALL

NEW SIGN #1 (DANGER - BOMBING RANGE) ON

EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

3. INSTALL NEW SIGN #1 (DANGER - BOMBING RANGE(

ON EXISTING PILING. EXISTING SIGN #2 (LASER

WARNING) TO REMAIN.

4. NO WORK INCLUDED FOR REFERENCE ONLY.

BOMBING RANGE BT-09

SIGN

NUMBER NORTHING EASTING SUMMARY OF WORK

A 43219.6800 228009.6200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

B 43185.7000 227996.1300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

C 43180.6600 227959.3000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

D 43159.4300 227942.8100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

E 43163.2500 227906.5500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

F 43166.0500 227886.6500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

G 43144.0400 227867.2400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

H 43136.5500 227835.9900

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

I 43120.2800 227825.0100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

J 43151.7600 227798.7300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

K 43170.4000 227816.8400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

L 43181.5100 227844.0100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

M 43205.6200 227856.5500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

N 43234.3500 227866.4400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

O 43259.8700 227870.8600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

P 43284.9400 227888.1500

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

Q 43277.2100 227910.5400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

R 43290.7400 227945.6800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

S 43323.2700 227941.9600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

T 43358.8400 227944.4800

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

U 43331.1600 227964.1400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

V 43293.1400 227977.5000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

W 43263.3000 228001.1900

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

X 43228.6800 228011.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

Y 43229.6800 228012.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

Z 43230.6800 228013.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

AA 43231.6800 228014.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

BB 43232.6800 228015.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

CC 43233.6800 228016.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

DD 43234.6800 228017.4600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

AA BBY Z

CC DD

B O

M B

IN

G

R A

N G

E B

T-

12891956

C-403

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

C

OM

MA

ND

M

ID

AT

LA

NT

IC

PR

OV

ID

E

PR

OH

IB

IT

ED

/R

ES

TR

IC

TE

D

SI

GN

S

AT

R

AN

GE

A

ND

T

RA

IN

IN

G

AR

EA

S

151 Poole Rd. Suite 100 | Leland, NC, 28451

TEL (910) 383-1044 | FAX (910) 383-1045

www.capefearengineering.com

N.C. LICENSE # C-1621

SUPPORT TRA INING

MCAS CHERRY POINT, NC

- 03-01-2024

7328487

GENERAL SHEET NOTES

SHEET KEYNOTES

7 BOMBING RANGE BT-09 COORDINATE TABLE

1 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

4 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

3 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

TYP

C-600

3 3

TYP

2 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

C-600 3 3

TYP

5 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

6 BOMBING RANGE BT-09

PLAN

NORTH

SCALE: 1" = 500'

SCALE: 1"=500'

250' 500' 1000' 1500'0

TYP

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

MAXIMO WORK ORDER NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

DES

AutoCAD SHX Text

DRW

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPR

AutoCAD SHX Text

DRAWFORM REVISION: 10 MARCH 2009

AutoCAD SHX Text

CHK

AutoCAD SHX Text

SATISFACTORY TO

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

ACTIVITY

AutoCAD SHX Text

DATE

AutoCAD SHX Text

FOR COMMANDER NAVFAC

AutoCAD SHX Text

SEAL

AutoCAD SHX Text

A/E INFO

AutoCAD SHX Text

OF

AutoCAD SHX Text

EPROJECT NO.:

AutoCAD SHX Text

MTH

AutoCAD SHX Text

ELB

AutoCAD SHX Text

MTH

AutoCAD SHX Text

IPT MARINE CORPS

AutoCAD SHX Text

NAVAL STATION - NORFOLK, VA

AutoCAD SHX Text

PM/DM

AutoCAD SHX Text

BRANCH MANAGER

AutoCAD SHX Text

CHIEF ENG/ARCH

AutoCAD SHX Text

FIRE PROTECTION

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

UNCLASSIFIED//FOR OFFICIAL USE ONLY

AutoCAD SHX Text

U.S. MARINE CORPS AIR STATION

AutoCAD SHX Text

CHERRY POINT, NORTH CAROLINA

AutoCAD SHX Text joness Snapshot

2. SEE SHEET C-002 FOR OVERALL SITE INDEX.

3. SEE SHEET C-100 FOR BOMBING RANGE BT-11 OVERALL

PLAN.

4. SENSITIVE FUSED MUNITIONS AND HIGH EXPLOSIVE

ORDINANCE UXO MAY BE PRESENT. A UXO TECHNICIAN

WILL BE REQUIRED TO CONDUCT A SUBSURFACE

SURVEY (I.E. WITH GROUND PENETRATING RADAR OR

OTHER TECHNICALLY ACCEPTED PRACTICE) TO DETECT

THE PRESENCE OF UXO. IF UXO IS LOCATED, THE SIGNS

WILL BE RELOCATED FROM THE POTENTIAL UXO AREA

TO A DISTANCE THAT IS DETERMINED BY THE UXO

TECHNICIAN TO BE SAFE FROM ALL GROUND

DISTURBING ACTIVITY ASSOCIATED WITH PYLON

INSTALLATION.

5. PRIOR TO WORK AT ANY LOCATION, CONTRACTOR MUST

NOTIFY RANGE OPS TO ENSURE THAT PLANNED

CONSTRUCTION ACTIVITIES DO NOT IMPACT RANGE

OPERATIONS.

6. WHEN WORKING ON BT-9 PERIMETER SIGNAGE,

CONTRACTOR IS REQUIRED TO ESTABLISH POSITIVE

COMMS ON MARITIME CHANEL 83A.

7. THERE MAY BE TIMES WHEN CONSTRUCTION WORK

NEEDS TO BE SUSPENDED BASED ON TRAINING

ACTIVITIES.

8. FOR ALL PILE DRIVEN OPEN WATER SIGNS,

CONTRACTOR TO PROVIDE A QUALIFIED MARINE

MAMMAL OBSERVER. JET DRIVEN PILES WILL NOT

REQUIRE OBSERVER.

9. OPEN WATER SIGNS WILL REQUIRE PERMITTING BY

CONTRACTOR.

1. INSTALL SIGN #5 (UNEXPLODED ORDINANCE - DO NOT

ENTER) ON NEW LAND MOUNTED POST.

© 2023 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS

BOMBING RANGE PAMLICO POINT

SIGN

NUMBER NORTHING EASTING SUMMARY OF WORK

1 48094.0900 229245.4300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

2 48060.1900 229242.5600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

3 48026.9500 229235.1000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

4 48000.3800 229212.1300

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

5 48023.8000 229188.9600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

6 48037.6700 229171.6200

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

7 48063.0000 229199.7000

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

8 48095.2800 229198.1600

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

9 48092.4000 229176.4400

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

10 48070.9400 229156.6100

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER) ON NEW LAND

MOUNTED POST

11 48059.0600 229133.3700

INSTALL SIGN #5

(UNEXPLODED ORDINANCE -

DO NOT ENTER)…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .