7263360 Amendment 0005.pdf

PDF 1 MB Posted

Attached to
Renovate Break Room and Entrance, B159 DLA
Solicitation number
N400857263360
Issued by

About this file

This is Amendment #0005 to NAVFAC Specification 7263360 for renovating the break room and entrance at Building 159 DLA at MCAS Cherry Point, NC. The amendment, dated February 10, 2025, provides answers to pre-award RFIs regarding cabinet hardware specifications.

The amendment clarifies that cabinet pulls shall be ABA standard U-shaped pull type (BHMA No. B02011) rather than the previously referenced "finished legend." The government indicates they need more information regarding a question about the casework schedule. The amendment includes a revised specification section 06 41 16.00 10 for Plastic-Laminate-Clad Architectural Cabinets dated February 10, 2025. The proposal due date remains February 20, 2025 at 12:00 PM local time, and the deadline for submitting pre-award RFIs has passed. The amendment must be acknowledged when submitting proposals, with failure to acknowledge potentially resulting in proposal rejection.

View the file

Other files

File Type Posted
7263360 Amendment 0006.pdf PDF
7263360 Amendment 0004.pdf PDF
7263360 Amendment 0003.pdf PDF
7263360 Amendment 0002.pdf PDF
7263360 Amendment 0001 - Updated.pdf PDF
RFP 7263360 - Updated.pdf PDF
7263360 Amendment 0001.pdf PDF
7263360 DrawingsAsOne SIGNED.pdf PDF
RFP 7263360.pdf PDF
7263360 SpecsAsOne SIGNED.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NAVFAC

SPECIFICATION

7263360 Renovate Break Room and

Entrance, B159 DLA

MCAS Cherry Point, NC

AMENDMENT #0005

IMPORTANT

This amendment should be acknowledged when your proposal is submitted. Failure to acknowledge the amendment may constitute grounds for rejection of the proposal.

If your proposal has been submitted prior to the receipt of this amendment, acknowledgement should be made by telegram, which should state whether the price contained in your proposal is to remain unchanged, is to be decreased by an amount, or is to be increased by an amount. The acknowledgement must be received prior to proposal opening time.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

1 2

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

0005 02/10/2025 7263360

6. ISSUED BY Code N40085 7. ADMINISTERED BY (If other than item 6.) Code

CG MCAS Cherry Point

FACILITIES, ROICC

B-163, CURTIS ROAD

PSC BOX 8006

CHERRY POINT, NC 28533

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) 9A. AMENDMENT OF SOLICITATION

Renovate Break Room and Entrance, B159

DLA

9B. DATED (SEE ITEM 11)

AMENDMENT MUST BE ACKNOWLEDGED WITH YOUR PROPOSAL 10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

CODE FACILITY CODE

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in item 14. The hour and date specified for receipt of Offers is extended is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing items 8 and 15, and returning 1 copy of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (if required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14. ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATION CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103 (b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER: (specify type of modification and authority)

E. IMPORTANT: Contractor is not is required to sign this document and return original to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

7263360 Renovate Break Room and Entrance, B159 DLA, Marine Corps Air Station Cherry Point, NC

Amendment 0005 is being issued to answer pre-award RFI’s.

The deadline to submit pre-award RFI’s HAS PASSED.

The proposal due date of 20 February 2025 at 12:00 PM local time REMAINS unchanged.

See Attached.

15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

15B. CONTRACTOR/OFFEROR (Same as Item 8) 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED

BY

(Signature of person authorized to sign) (Signature of Contracting Officer)

NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV.1-83) 0224-3(10-90)

PREVIOUS EDITION UNUSABLE Prescribed by GSA mason.sholar Highlight

Amendment 0005 7263360 Renovate Break Room and Entrance, B159 DLA

RFI Responses:

1. Section 06 41 16.00 10 paragraph 2.5.2 Cabinet Pulls states “See finished legend.” There are no details provided for the desired pull; however, industry standard is a 4” wire pull, back mounted.

Please clarify.

Response:

See revised spec section 06 41 16.00 10 dated 10 FEB 2025. Submit proposals in accordance with RFP, Specifications, Drawings and all amendments.

2. What is the casework schedule for this project?

Response:

Govt is unclear of the meaning of this question. Please submit question with more information.

Submit proposals in accordance with RFP, Specifications, Drawings and all amendments.

Subj: AMENDMENT TO WO 7263360 Renovate Break Room and Entrance, B159 DLA, MCAS CHERRY POINT NC

CONTINUATION SHEET

PROJECT TABLE OF CONTENTS

SECTION 06 41 16.00 10, PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS is deleted and 06 41 16.00 10, PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS, dated 10 FEB 2025, as shown in the footer, is added to the Project Table of Contents and accompanies this Amendment.

Renovate Break Room and Entrance, B159 7263360

SECTION 06 41 16.00 10

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

08/10, CHG 1: 11/18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A161.2 (1998) Decorative Laminate Countertops, Performance Standards for Fabricated High Pressure

ASTM INTERNATIONAL (ASTM)

ASTM F547 (202) Standard Terminology of Nails for Use with Wood and Wood-Base Materials

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9 (2020) Cabinet Hardware

COMPOSITE PANEL ASSOCIATION (CPA)

CPA A208.2 (2016) Medium Density Fiberboard (MDF) for Interior Applications

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors

WOODWORK INSTITUTE (WI)

NAAWS 3.1 (2017; 2018 Errata Edition) North American Architectural Woodwork Standards

1.2 SYSTEM DESCRIPTION

Work in this section includes laminate clad custom casework cabinets as shown on the drawings and as described in this specification. This Section includes high-pressure laminate surfacing and cabinet hardware.

Sand smooth and apply a clear finish of polyurethane to all exposed and semi-exposed surfaces, whose finish is not otherwise noted on the drawings or finish schedule. Wood finish may be shop finished or field applied in accordance with Section 09 90 00 PAINTS AND COATINGS.

SECTION 06 41 16.00 10 Page 1

REVISED 10 FEB 2025

1.3 SUBMITTALS

Government approval is required for all submittals . Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Shop Drawings Installation

SD-03 Product Data

Wood Materials Wood Finishes Finish Schedule

SD-04 Samples

Plastic Laminates Cabinet Hardware

SD-07 Certificates

Quality Assurance Laminate Clad Casework

1.4 QUALITY ASSURANCE

1.4.1 General Requirements

Unless otherwise noted on the drawings, furnish all materials, construction methods, and fabrication conforming to and complying with the custom grade quality standards as outlined in NAAWS 3.1, Section for laminate clad cabinets. These standards apply in lieu of omissions or specific requirements in this specification. Contractors and their personnel engaged in the work must be able to demonstrate successful experience with work of comparable extent, complexity and quality to that shown and specified. Submit a quality control statement which illustrates compliance with and understanding of NAAWS 3.1 requirements, in general, and the specific NAAWS 3.1 requirements provided in this specification.

The quality control statement must also certify a minimum of ten years Contractor's experience in laminate clad casework fabrication and construction. Provide a list of a minimum of five successfully completed projects of a similar scope, size, and complexity in the quality control statement.

1.4.2 Mock-ups

Prior to final approval of shop drawings , provide a full-size mock-up of a typical floor cabinet wall cabinet , including all components and hardware necessary to illustrate a completed unit with a minimum of one door and one drawer assembly. Include countertops and back splashes where specified. Utilize specified finishes in the patterns and colors as indicated . Upon disapproval, rework or remake the mock-up until approval is secured. Remove rejected units from the jobsite. Approved mock-up may remain as part of the finished work. Submit shop drawings showing all fabricated casework items in plan view, elevations and cross-sections to accurately indicate materials used, details of construction, dimensions, methods of fastening and erection, and installation methods proposed.

SECTION 06 41 16.00 10 Page 2

Clearly cross-reference shop drawing casework items to casework items located on the project drawings. Shop drawings will include a color schedule of all casework items to include all countertop, exposed, and semi-exposed cabinet finishes to include finish material manufacturer, pattern, and color.

1.5 DELIVERY, STORAGE, AND HANDLING

Casework may be delivered knockdown or fully assembled. Deliver all units to the site in undamaged condition, stored off the ground in fully enclosed areas, and protected from damage. Ventilate the storage area and do not subject to extreme changes in temperature or humidity.

1.6 SEQUENCING AND SCHEDULING

Coordinate work with other trades. Do not install units in any room or space until painting, and ceiling installation are complete within the room where the units are located. Install floor cabinets before finished flooring materials are installed.

PART 2 PRODUCTS

2.1 WOOD MATERIALS

2.1.1 Lumber

a. Provide kiln-dried Grade III framing lumber to dimensions as shown on the drawings. Frame front, where indicated on the drawings, must be nominal 3/4 inch hardwood.

2.1.2 Panel Products

2.1.2.1 Plywood

Use veneer core hardwood plywood, NAAWS 3.1 Grade AA panels for framing purposes. Indicate nominal thickness of plywood panels in this specification and on the drawings.

2.1.2.2 Medium Density Fiberboard

Medium density fiberboard (MDF) must be an acceptable panel substrate where noted on the drawings. Provide medium density fiberboard meeting the minimum standards listed in CPA A208.2 .

2.2 SOLID POLYMER MATERIAL

Provide solid surfacing casework components in conformance to the requirements of Section 06 61 16 SOLID SURFACING FABRICATIONS.

2.3 HIGH PRESSURE DECORATIVE LAMINATE (HPDL)

Provide plastic laminates meeting the requirements of ANSI/NEMA LD 3 and ANSI A161.2 for high-pressure decorative laminates. Indicate design, colors, surface finish and texture, and locations on the drawings. Submit two samples of each plastic laminate pattern and color. Samples less than 5 by 7 inches in size are not acceptable. Provide plastic laminate types and nominal minimum thicknesses for casework components as indicated in the following paragraphs.

SECTION 06 41 16.00 10 Page 3

2.3.1 Horizontal General Purpose Standard (HGS) Grade

Provide horizontal general purpose standard grade plastic laminate that is

0.048 inches (plus or minus 0.005 inches) in thickness. This laminate grade is intended for horizontal surfaces where postforming is not required.

2.3.2 Vertical General Purpose Standard (VGS) Grade

Provide vertical general purpose standard grade plastic laminate that is

0.028 inches (plus or minus 0.004 inches) in thickness. This laminate grade is intended for exposed exterior vertical surfaces of casework components where postforming is not required.

2.3.3 Cabinet Liner Standard (CLS) Grade

Provide cabinet liner standard grade plastic laminate that is 0.020 inches in thickness. This laminate grade is intended for light duty semi-exposed interior surfaces of casework components.

2.3.4 Backing Sheet (BK) Grade

Undecorated backing sheet grade laminate is formulated specifically to be used on the backside of plastic laminated panel substrates to enhance dimensional stability of the substrate. Backing sheet thickness must be

0.020 inches . Provide backing sheets for all laminated casework components where plastic laminate finish is applied to only one surface of the component substrate.

2.4 EDGE BANDING

Provide PVC vinyl, 0.020 inch thick, edge banding for casework doors and drawer fronts. Material width must be as indicated on the drawings.

Color and pattern must match exposed door and drawer front laminate pattern and color.

2.5 CABINET HARDWARE

Submit one sample of each cabinet hardware item specified to include hinges, pulls, and drawer glides. Provide hardware conforming to ANSI/BHMA A156.9 , unless otherwise noted, and consisting of the following components:

2.5.1 Door Hinges

Concealed European hinge type.

2.5.2 Cabinet Pulls

ABA standard U-shaped pull type, BHMA No. B02011 .

2.5.3 Drawer Slide

Side mounted type, full extension and a minimum 75 pound load capacity.

Include an positive stop to avoid accidental drawer removal.

2.5.4 Adjustable Shelf Support System

Multiple holes with metal pin supports.

SECTION 06 41 16.00 10 Page 4

2.6 FASTENERS

Provide nails, screws, and other suitable fasteners that are the size and type best suited for the purpose and conforming to ASTM F547 where applicable.

2.7 ADHESIVES, CAULKS, AND SEALANTS

2.7.1 Adhesives

Use formula and type of adhesives recommended by AWI. Select adhesives for their ability to provide a durable, permanent bond and take into consideration such factors as materials to be bonded, expansion and contraction, bond strength, fire rating, and moisture resistance. Meet local regulations regarding VOC emissions and off-gassing.

2.7.1.1 Wood Joinery

Use Type II for interior use urea-formaldehyde resin formula adhesives to bond wood members. Adhesives must withstand a bond test as described in

ANSI/WDMA I.S.1A .

2.7.1.2 Laminate Adhesive

Adhesive used to join high-pressure decorative laminate to wood must be adhesive consistent with AWI and laminate manufacturer's recommendations.

Adhere PVC edgebanding using a polymer-based hot melt glue.

2.7.2 Caulk

Use clear, 100 percent silicone caulk to fill voids and joints between laminated components and between laminated components and adjacent surfaces.

2.7.3 Sealant

Use sealant recommended by the substrate manufacturer to provide a moisture barrier at sink cutouts and all other locations where unfinished substrate edges may be subjected to moisture.

2.8 WOOD FINISHES

Paint, stain, varnish and perform applications required for laminate clad casework components as indicated on the drawings . Indicate color and location on the drawings.

2.9 FABRICATION

Verify field measurements as indicated in the shop drawings before fabrication. Accomplish fabrication and assembly of components at the shop site to the maximum extent possible. Meet or exceed the requirements for AWI custom grade unless otherwise indicated in this specification.

Make cabinet style, in accordance with NAAWS 3.1, Section 400-G descriptions, as indicated on the drawings.

SECTION 06 41 16.00 10 Page 5

2.9.1 Base and Wall Cabinet Case Body

2.9.1.1 Cabinet Components

Use frame members that are glued-together, kiln-dried hardwood lumber.

Brace top corners, bottom corners, and cabinet bottoms with either hardwood blocks or water-resistant glue and nailed in place metal or plastic corner braces. Construct cabinet components from the following materials and thicknesses:

2.9.1.1.1 Body Members (Ends, Divisions, Bottoms, and Tops)

3/4 inch medium density fiberboard (MDF) or veneer core plywood panel product

2.9.1.1.2 Face Frames and Rails

3/4 inch hardwood lumber or panel product

2.9.1.1.3 Shelving

3/4 inch medium density fiberboard (MDF) or veneer core plywood panel product

2.9.1.1.4 Cabinet Backs

1/4 inch medium density fiberboard (MDF) or veneer core plywood panel product

2.9.1.1.5 Drawer Sides, Backs, and Subfronts

1/2 inch hardwood lumber or panel product

2.9.1.1.6 Drawer Bottoms

1/4 inch medium density fiberboard (MDF) or veneer core plywood panel product

2.9.1.1.7 Door and Drawer Fronts

3/4-inch medium density fiberboard (MDF) panel product

2.9.1.2 Joinery Method for Case Body Members

2.9.1.2.1 Tops, Exposed Ends, and Bottoms

a. Steel "European" assembly screws ( 1-1/2 inch from end, 5 inch on center, fasteners will not be visible on exposed parts).

b. Doweled, glued under pressure (approx. 4 dowels per 12 inches of joint).

c. Stop dado, glued under pressure, and either nailed, stapled or screwed (fasteners will not be visible on exposed parts).

d. Spline or biscuit, glued under pressure.

SECTION 06 41 16.00 10 Page 6

2.9.1.2.2 Exposed End Corner and Face Frame Attachment

2.9.1.2.2.1 Mitered Joint

lock miter or spline or biscuit, glued under pressure (no visible fasteners)

2.9.1.2.2.2 Non-Mitered Joint (90 degree)

butt joint glued under pressure (no visible fasteners)

2.9.1.2.2.3 Butt Joint

glued and nailed

2.9.1.2.3 Cabinet Backs (Wall Hung Cabinets)

Wall hung cabinet backs must not be relied upon to support the full weight of the cabinet and its anticipated load for hanging/mounting purposes.

Method of back joinery and hanging/mounting mechanisms should transfer the load to case body members. Use the following fabrication method:

2.9.1.2.3.1 Full Bound

Full bound, captured in grooves on cabinet sides, top, and bottom.

Cabinet backs for floor standing cabinets must be side bound, captured in grooves; glued and fastened to top and bottom.

2.9.1.2.3.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inch and minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.9.1.2.3.3 Side Bound

Side bound, captured in groove or rabbetts; glued and fastened.

2.9.1.2.4 Cabinet Backs (Floor Standing Cabinets)

2.9.1.2.4.1 Side Bound

Side bound, captured in grooves; glued and fastened to top and bottom.

2.9.1.2.4.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inch and minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.9.1.2.4.3 Side Bound with Rabbetts

Side bound, placed in rabbetts; glued and fastened in rabbetts.

2.9.1.2.5 Wall Anchor Strips

Wall Anchor Strips are required for all cabinets with backs less than 1/2

SECTION 06 41 16.00 10 Page 7 inch thick. Use strips consisting of minimum 1/2 inch thick lumber, minimum 2-1/2 inches width; securely attache to wall side of cabinet back

- top and bottom for wall hung cabinets, top only for floor standing cabinets.

2.9.2 Cabinet Floor Base

Mount floor cabinets on a base constructed of 3/4 inch veneer core exterior plywood. Provide base assembly components that are a moisture-resistant panel product. Make finished height for each cabinet base as indicated on the drawings. Make bottom edge of the cabinet door or drawer face flush with top of base.

2.9.3 Cabinet Door and Drawer Fronts

Fabricate door and drawer fronts from 3/4 inch medium density fiberboard (MDF. Surface all door and drawer front edges with high pressure plastic laminate, color and pattern as indicated on the drawings.

2.9.4 Drawer Assembly

2.9.4.1 Drawer Components

Provide drawer components consisting of a removable drawer front, sides, backs, and bottom. Construct drawer components of the following materials and thicknesses:

2.9.4.1.1 Drawer Sides and Backs For Transparent Finish

1/2 inch thick 7-ply hardwood veneer core plywood (no voids), any species

2.9.4.1.2 Drawer Sides and Backs For Laminate Finish

1/2 inch thick 7-ply hardwood veneer core substrate

2.9.4.1.3 Drawer Sides and Back For Thermoset Decorative Overlay (Melamine) Finish

1/2 inch thick medium density particleboard or MDF fiberboard substrate

2.9.4.1.4 Drawer Bottom

1/4 inch thick veneer core panel product for transparent or plastic laminate finish

2.9.4.2 Drawer Assembly Joinery Method

a. Multiple dovetail (all corners) or French dovetail front/dadoed back, glued under pressure.

b. Doweled, glued under pressure.

c. Lock shoulder, glued and pin nailed.

d. Set bottoms into sides, front, and back, 1/4 inch deep groove with a minimum 3/8 inch standing shoulder.

SECTION 06 41 16.00 10 Page 8

2.9.5 Shelving

2.9.5.1 General Requirements

Fabricate shelving from 3/4 inch medium density fiberboard (MDF. Finish all shelving top and bottom surfaces with HPDL plastic laminate. Finish shelf edges in a PVC edgebanding.

2.9.5.2 Shelf Support System

The shelf support system is as follows:

2.9.5.2.1 Recessed (Mortised) Metal Shelf Standards

Mortise standards flush with the finishes surface of the cabinet interior side walls, two per side. Pposition and space standards on the side walls to provide a stable shelf surface that eliminates tipping when shelf front is weighted. Install and adjust standards vertically to provide a level, stable shelf surface when clips are in place.

2.9.5.2.2 Pin Hole Method

Drill holes on the interior surface of the cabinet side walls. Evenly space holes in two vertical columns Space the holes in each column at 1 inch increments starting 6 inches from the cabinet interior bottom and extending to within 6 inches of the top interior surface of the cabinet.

Drill holes to provide a level, stable surface when the shelf is resting on the shelf pins. Coordinate hole diameter with pin insert size to provide a firm, tight fit.

2.9.6 Laminate Application

Apply laminate to substrates following the recommended procedures and instructions of the laminate manufacturer and ANSI/NEMA LD 3 , using tools and devices specifically designed for laminate fabrication and application. Provide a balanced backer sheet (Grade BK) wherever only one surface of the component substrate requires a plastic laminate finish.

Apply required grade of laminate in full uninterrupted sheets consistent with manufactured sizes using one piece for full length only, using adhesives specified herein or as recommended by the manufacturer. Fit corners and joints hairline. Machined flush, file, sand, or buff all laminate edges to remove machine marks and ease (sharp corners removed).

Clean up at easing must be such that no overlap of the member eased is visible. Perform fabrication in conformance to ANSI A161.2 . Provide laminate types and grades for component surfaces as follows unless otherwise indicated on the drawings:

2.9.6.1 Base/Wall Cabinet Case Body

a. Exterior (exposed) surfaces to include exposed and semi-exposed face frame surfaces: HPDL Grade VGS.

b. Interior (semi-exposed) surfaces to include interior back wall, bottom, and side walls: HPDL Grade CLS.

SECTION 06 41 16.00 10 Page 9

2.9.6.2 Adjustable Shelving

2.9.6.2.1 Top and Bottom Surfaces

HPDL Grade HGS

2.9.6.2.2 All Edges

PVC edgebanding

2.9.6.3 Fixed Shelving

2.9.6.3.1 Top and Bottom Surfaces

HPDL Grade HGS

2.9.6.3.2 Exposed Edges

PVC edgebanding

2.9.6.4 Door, Drawer Fronts, Access Panels

2.9.6.4.1 Exterior (Exposed) and Interior (Semi-Exposed) Faces

HPDL Grade VGS

2.9.6.4.2 Edges

PVC edgebanding

2.9.6.5 Drawer Assembly

All interior and exterior surfaces: HPDL Grade CLS.

2.9.6.6 Countertops and Splashes

All exposed and semi-exposed surfaces: HPDL Grade HGS

2.9.6.7 Tolerances

Meet the NAAWS 3.1 custom grade requirements for flushness, flatness, and joint tolerances of laminated surfaces.

2.9.7 Finishing

2.9.7.1 Filling

Do not expose fasteners on laminated surfaces. Make all nails, screws, and other fasteners in non-laminated cabinet components countersunk and fill the holes with wood filler consistent in color with the wood species.

2.9.7.2 Sanding

Prepare all surfaces requiring coatings by sanding with a grit and in a manner that scratches will not show in the final system.

2.9.7.3 Coatings

Types, method of application and location of casework finishes must be in

SECTION 06 41 16.00 10 Page 10 accordance with the finish schedule , drawings and Section 09 90 00 PAINTS AND COATINGS. Paint all cabinet reveals. Submit descriptive data which provides narrative written verification of all types of construction materials and finishes, methods of construction, etc. not clearly illustrated on the submitted shop drawings. Provide written verification of conformance with NAAWS 3.1 for the quality indicated to include materials, tolerances, and types of construction. Both the manufacturer of materials and the fabricator must submit available literature which describes re-cycled product content, operations and processes in place that support efficient use of natural resources, energy efficiency, emissions of ozone depleting chemicals, management of water and operational waste, indoor environmental quality, and other production techniques supporting sustainable design and products.

PART 3 EXECUTION

3.1 INSTALLATION

Installation must comply with applicable requirements for NAAWS 3.1 custom quality standards. Install countertops and fabricated assemblies level, plumb, and true to line, in locations shown on the drawings. Attach and securely anchor cabinets and other laminate clad casework assemblies to the floor and walls with mechanical fasteners that are appropriate for the wall and floor construction.

3.1.1 Anchoring Systems

3.1.1.1 Floor

Utilize a floor anchoring system as detailed on the drawings for base cabinets. Anchoring and mechanical fasteners must not be visible from the finished side of the casework assembly. Attach cabinet assemblies to anchored bases without visible fasteners as indicated in the drawings.

Where assembly abuts a wall surface, include a minimum 1/2 inch thick lumber or panel product hanging strip, minimum 2-1/2 inch width; securely attached to the top of the wall side of the cabinet back.

3.1.1.2 Wall

Utilize minimum 1/2 inch thick lumber or panel product hanging strips, minimum 2-1/2 inch width to wall mount cabinet; securely attach to the wall side of the cabinet back, both top and bottom.

3.1.2 Countertops

Install countertops in locations as indicated on the drawings. Fasten countertops to supporting casework structure with mechanical fasteners, hidden from view. Fill all joints formed by the countertop or countertop splash and adjacent wall surfaces with a clear silicone caulk. Adhere loose back splashes to both the countertop surface perimeter and the adjacent wall surface with adhesives appropriate for the type of materials to be adhered. Fill joints between the countertop surface and splash with clear silicone caulk in a smooth consistent concave bead. Bead size must be the minimum necessary to fill the joint and any surrounding voids or cracks.

3.1.3 Hardware

Install casework hardware in types and locations as indicated on the

SECTION 06 41 16.00 10 Page 11 drawings. Where fully concealed European-style hinges are specified to be used with particleboard or fiberboard doors, use plastic or synthetic insertion dowels to receive 3/16 inch "Euroscrews". The use of wood screws without insertion dowels is prohibited.

3.1.4 Doors, Drawers and Removable Panels

Accomplish the fitting of doors, drawers and removable panels within target fitting tolerances for gaps and flushness in accordance with NAAWS 3.1 custom grade requirements.

3.1.5 Plumbing Fixtures

Install sinks, sink hardware, and other plumbing fixtures in locations as indicated on the drawings and in accordance with Section 22 00 00

PLUMBING, GENERAL PURPOSE.

-- End of Section --

SECTION 06 41 16.00 10 Page 12

File details come from the government source that posted it. Updated .