This document is a set of architectural and construction drawings for a partial renovation of Building G560 located at U.S. Marine Corps Base Camp Lejeune, North Carolina. The scope of work encompasses renovation of interior and exterior areas including flooring, suspended ceiling systems, wainscoting, doors, windows, bathroom fixtures, lighting, plumbing, electrical systems, and various interior finishes.
The contractor is responsible for demolition of existing materials (tile carpet, suspended ceiling, wainscoting, wall assemblies, built-in cabinets, and bathroom fixtures), installation of new systems and finishes, and site supervision under the direction of the Contracting Officer's Representative. Key work areas include the main office, kitchen, dining room, family/handicap restroom, women's and men's restrooms, theater, and associated hallways. Specific requirements include installation of new luxury vinyl tile flooring, new suspended ceiling systems (15/16" tee grid manufactured by Certainteed), new wainscoting, new interior and exterior doors with glazing, new bathroom fixtures and vanities, new countertops with solid surface material, new lighting fixtures, a packaged terminal heat pump in the manager's office, HVAC grille replacement, and various painting and finishing work. All hazardous materials (vinyl asbestos floor tile, glazing compound, and previously painted exterior surfaces) must be managed in accordance with applicable regulations. The Base Landfill is available for disposal of debris, and contractors must maintain a Fire Watch and comply with NFPA 51B standards during hot work operations.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend02.pdf | ||
| 24-0030 Drawings - Amendment 001.pdf | ||
| 82-2371 G560 Addition As-Builts.pdf | ||
| 75-0919 As-Builts.pdf | ||
| Amend01.pdf | ||
| RFP 240030.pdf | ||
| N4008524B0030 Specs.pdf | ||
| 24-0030 ACM REPORT.pdf | ||
| N4008524B0030 Dwgs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NWALLACE
Typewritten Text As-Built
PA 18, 20
M10
NWALLACE
Line
NWALLACE
Line
NWALLACE
Typewritten Text
MP10
NWALLACE
Line
NWALLACE
Typewritten Text
PLP7
NWALLACE
Line
NWALLACE
Typewritten Text
PLP7
nwallace Typewritten Text
PLP-1
nwallace Line nwallace Typewritten Text
MP-8
NWALLACE
Typewritten Text
PLP-1
NWALLACE
Line
NWALLACE
Line
NWALLACE
Line
NWALLACE
Line
NWALLACE
Line
NWALLACE
Line
NWALLACE
Oval
NWALLACE
Line
NWALLACE
Line
Oval m7
NWALLACE
MP40
| g560-1 Title Page |
| g560-2 A1 Demo |
| g560-3 A2 Floor Plan |
| g560-4 A3 Floor Plan (2) |
| g560-5 A4 Floor Plan (3) |
| g560-6 A5 Floor Plan (4) |
| g560-7 A6 Elevations |
| g560-8 A7 Details |
| g560-9 A8 Ceiling Plan |
| g560-10 A9 Flooring Plan |
| g560-11 A10 Ext Doors |
| g560-12 A11 Int Doors |
| g560-13 M1 Mech Plan |
| g560-14 P1 Plumbing Demo |
| g560-15 P2 Plumbing New |
| g560-16 E1 Demo |
| g560-17 E2 Lighting |
| g560-18 E3 Recp Serving Line |
| g560-19 E4 Theater |
File details come from the government source that posted it. Updated .