This document is an Amendment of Solicitation/Modification of Contract for a roof repair project (Solicitation N40085-26-R-9004) issued by NAVFAC Mid-Atlantic. Amendment 0002 addresses two key technical questions from potential contractors: 1) how to handle soffit light fixtures during renovation (contractors are permitted to remove and reinstall fixtures as needed), and 2) specific requirements for gutter and downspout dimensions (6" x 7" gutter and 5" x 6" downspout sizes must be strictly followed, despite manufacturer's standard details). The amendment maintains the original proposal receipt date and serves to clarify technical specifications for the roof repair project at a specific location, with the project number 24-0021. The document includes a sign-in sheet with contact information for various organizations and individuals potentially involved in the solicitation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend 0004.pdf | ||
| Amend 0003.pdf | ||
| Amend 0001.pdf | ||
| N4008524B0021 Dwgs.pdf | ||
| 24-0021 APPXD.pdf | ||
| RFP 240021.pdf | ||
| N4008524B0021 Specs.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N40085-26-R-9004 Amendment 0002
CONTINUATION SHEET
1. QUESTION: GENERAL SHEET NOTE "G" on Drawing AD101states "Soffit Light Fixtures shall remain in place: Work soffit materials around existing fixture rough-ins and reinstall all trims after new materials are in place." GENERAL ARCHITECTURAL NOTES #9 on Drawing A-001 states "Any Device Damaged by Contractor is to be Replaced by the Contractor". Our experience with Soffit panels and Soffit Light fixtures will not allow new panels to be properly removed or installed with the light fixture remaining in place. Some fixtures are installed through a hole cut in just one panel and will not allow the panel to be removed without potentially damaging the light fixture. It is our recommendation that the soffit light fixtures be removed and reinstalled the same as the fascia light fixtures.
ANSWER: Remove as required, and reinstall.
2. QUESTION: SHEET KEYNOTES # 2 and 3 on Drawing A-500 show a 6" x 7" Gutter and a 5" x 6" Downspout. The spec section for the new Roof Panels 07 61 15.00 20 is the Garland Basis of design. Garlands details for Gutter and Downspouts show a 6"x6" Gutter and a 3"x4" downspout. Will the Garland details for Gutter and Downspouts, that will be submitted with the Garland Shop Drawings, be acceptable?
ANSWER: No, size per sheet A-500.
3. All other terms and conditions remain unchanged.