This file is an asbestos survey report dated August 11, 2024, detailing inspections of multiple buildings at Marine Corps Base Camp Lejeune scheduled for demolition. The survey, conducted by The Walker Group Architecture, Inc., assessed 48 buildings/structures between April 2020 and August 2024 for asbestos-containing materials (ACM). The report identifies several buildings containing ACM, including Building 203 (exterior textured concrete foundation - 780SF), Building 203A (exterior textured concrete foundation - 96SF), Building 1014 (coating on exterior metal wall panels - 3510SF), Building AS849 (exterior expansion joints - 48LF), and Building TC1003 (exterior caulk at pilasters - 50LF).
The file also includes a pre-solicitation notice (N4008525B2500) for demolition work at Camp Lejeune, indicating the contract will be set aside for small businesses under NAICS code 238910 with a size standard of $16.5 million. The contractor must be certified to remove and transport hazardous materials. The solicitation will be available for download around January 30, 2025, with proposals due 30 days after issuance. A 20% bid bond is required with proposals. The work will be awarded through sealed bidding under FAR Part 14.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 252500Lead SurveyReport.pdf | ||
| 252500SOW and Specification.pdf | ||
| SOLN4008525B2500.pdf | ||
| 252500Drawings.pdf | ||
| 25B2500 Amend 0001.pdf | ||
| PreSolic_25B2500.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey IR Demo Package FY24 - MCB Camp Lejeune
IR Demo Package FY24
MCB Camp Lejeune Project # 23-0036
Report Prepared By:
Christopher B. Walker The Walker Group Architecture, Inc
August 11th, 2024 WGA Project No. – 2402.FY24
Project Information
The Walker Group Architecture, Inc. was contracted by NRW Engineering to conduct an asbestos sampling survey for Buildings/Structures at Camp Lejeune: 114, 203, 203A, 401, 401A, 528, 728, 1005A, 1014, 1306, 1742A, 1742B, 1742C, AS251, AS849, AS852, AS3906, AS3450, AS3540, AS3990, H206, H207, H208, H209, LCH4034, RR27, RR28, RR108, S185, SAS4215, SBB229, SFC408, SFC499, SFC581, SRR65, SRR66, SHP455A, SRR65, SRR66, SRR93, SRR105, ST13, TC1003, VL60, VL61, VL325, SHP306A, SHP308A, AST27, AST27A, AST27B, LCH4034 Generator Stand. The specified buildings or structures are slated for demolition on board Marine Corps Base. An asbestos survey has been requested prior to disturbance of any potential asbestos containing materials (ACM).
The following buildings/structures were inspected with no suspect asbestos containing materials found during the inspection: AS852, AS903A, AS903B, S185, SAS4215, SRR65, SRR66, SRR93, SRR105, VL60, VL325, SHP306A, SHP308A, AST27, AST27A, AST27B, and LCH4034 generator stand.
Scope of Services
A. The survey was performed on 04/03/20, 04/20/20, 11/04/21, 07/03/24, 07/29/24, 07/18/24, 08/12/24 by Christopher B. Walker (NC Accredited Inspector #12878, expires July 31st, 2025). The sampling was conducted in general accordance with the U.S. Environmental Protection Agency (EPA) requirements as defined in the asbestos Hazards Emergency Response Act (40 CFR Part 763) guidelines (AHERA) and in general accordance with the North Carolina Health Hazards Control Unit (NCHHCU).
B. The survey was conducted to identify the presence of asbestos containing materials (ACM) prior to building demolition.
C. The buildings were assessed to determine homogenous areas (groups of materials appearing to have been installed in the same general time period and uniform in color and texture).
D. As per AHERA, sufficient samples were collected from random locations of each homogenous area, with the number of samples based on the following criteria:
a. Thermal Insulation Materials (piping, breeching, boiler insulation, etc.) – A minimum of (3) samples are required. Patch areas (less than 6 square or liner feet) may have (2) sample collected.
b. Surfacing Materials (plaster, fireproofing, etc.) – A minimum of (7) samples are to be taken for areas greater than 5,000 square feet, five (5) samples for areas greater than 1,000 square feet, but less than 5,000 square feet, three (3) samples for areas less than 1,000 square feet, two (2) samples for patching materials.
c. Miscellaneous Materials (flooring, adhesives, roofing, wallboard, etc.) – A minimum of (2) samples are required.
If any one sample of a material from a homogenous area is found to be positive, then that material is considered positive, regardless of results of other samples of that material, within that area.
Samples
A. The Walker Group Architecture collected suspect samples and shipped them to EMSL Analytical, Inc. (NVLAP Accredited Laboratory 102104-0) for PLM (polarized Light Microscopy) analysis. In an effort to reduce cost, the Walker Group instructed the laboratory to Stop Analysis at the first positive sample for each suspect material HGA and not to analyze the remaining samples from the same HGA.
Building 114
Building Description and Findings (Inspected 07-03-24)
Building 114 is a vacant office building. The building is constructed with concrete foundation, brick exterior walls, metal stud interior walls with plaster and gypsum board. The building has a standing seam metal roof system. HVAC is provided through a forced air mechanical system.
A. Laboratory Results
Material Material
Type Location Friability Laboratory Result Approx.Quantity
Cream vct/mastic Misc Int. Floors NF Non-Detected N/A Interior plaster Surf. Int. Walls F Non-Detected N/A Exterior window caulk
Misc Ext. Windows NF Non-Detected N/A
Rubber base/mastic Misc Interior wall base NF Non-Detected N/A
Gypsum board/joint compound Misc Int. Walls NF Non-Detected N/A HVAC duct mastic Misc HVAC Duct NF Non-Detected N/A
Based on the sample analysis none of the materials sampled were found to be Asbestos Containing Materials.
ACM Materials found in previous government provided report:
-Exterior residual caulking- 408LF
- 12” cream vct/mastic- 774SF
Materials found to contain asbestos in the current inspection report and government provided inspection report should all be considered for the purpose of any demolition/renovation activities and disturbance. See Appendix for Government provided reports.
Building 203
Building 203 is a vacant office building. The building is constructed with concrete foundation, brick exterior walls, metal stud interior walls with plaster and gypsum board. The building has an asphalt shingle roof system.
HVAC is provided through a forced air mechanical system.
B. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
2x2 ACT Misc Ceilings NF Non-Detected N/A carpet mastic Misc Carpeted floors NF Non-Detected N/A plaster perimeter walls Misc Int. Walls at perimeter NF Non-Detected N/A gypsum board/joint compound
Misc Int. walls NF Non-Detected N/A ext. door/window caulk
Surf. Ext.
doors/windows
NF Non-Detected N/A
Ext. textured concrete Surf. Exterior Foundation wall
NF 3% Chrysotile 780SF asphalt shingles/felt Misc Roof NF Non-Detected N/A roof caulk at exhaust board Misc Roof penetration NF Non-Detected N/A
Based on the sample analysis, the following materials were found to be Asbestos Containing Materials.
Exterior textured concrete foundation
-Residual Door/window caulk- approx. 368lf -Joint material at interior wall seams- approx 96sf
Building 203A
Building 203 is a support building for building 203. The building is constructed with concrete foundation, and brick exterior walls. The building has an asphalt shingle roof system.
C. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Ext. door caulk Misc Exterior Door NF Non-Detected N/A Asphalt shingles/felt Misc Roof NF Non-Detected N/A Ext. textured concrete Surf. Exterior building foundation
NF 2% Chrysotile 96SF
Exterior textured concrete foundation
-Exterior caulk at door jamb and gable end trim- approx. 20lf
Building 401
Building Description and Findings (Inspected 07-29-24)
Building 401 is a vacant physical training and office building. The building is constructed with concrete foundation, and brick exterior walls, gypsum board interior walls. The building has an asphalt shingle roof system. HVAC is provided with a forced air mechanical system in the attic.
D. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A Gypsum board/joint compound Misc Int. Walls NF Non-Detected N/A Athletic floor mastic Misc. Int. gym Floor NF Non-Detected N/A Gray 12x12 VCT/Mastic Misc. Interior floors NF Non-Detected N/A Cream 12x12 VCT/Mastic Misc. Interior floors NF Non-Detected N/A Black rubber base/mastic Misc. Interior wall base NF Non-Detected N/A Exterior door/window caulk Misc. Exterior door/windows NF Non-Detected N/A
Exterior stucco porch ceiling Surf. Exterior porch ceiling
NF Non-Detected N/A
Exterior door/window caulk
Building 401A
Building Description and Findings (Inspected 07-29-24)
Building 401A is a mechanical support building for Building 401. The building is constructed with concrete foundation, brick and cmu exterior walls. The building has an asphalt shingle roof system.
E. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A
Building 528
Building 528 is a vacant storage building. The building is constructed with concrete foundation, brick exterior walls, metal stud interior walls with wood and gypsum board. The building has an asphalt shingle roof system.
Location Friability Laboratory Result Approx.Quantity
2x4 ACT Misc Ceilings NF Non-Detected N/A Gypsum board/joint compound Misc Interior walls NF Non-Detected N/A Int. perimeter wall exp. Misc Expansion joint at interior NF Non-Detected N/A
Ext. window caulk Misc Ext. windows NF Non-Detected N/A Asphalt shingles/felt Misc roof NF Non-Detected N/A Caulk at roof vent Misc Roof vents NF 5% Chrysotile 36LF
Caulk at roof vents
-Transite panel material- approx. 1,600sf
Building 728
Building Description and Findings (Inspected 07-03-2024)
Building 728 is a vacant office building. The building is a wood framed building with exterior vinyl siding, asphalt shingle roof, wood interior framing and gypsum board walls. Most of the flooring in the building was VCT. HVAC is provided through a forced air mechanical system.
Location Friability Laboratory Result Approx.Quantity
Blue 12x12 vct/mastic Misc Flooring NF Non-Detected N/A Cream 12x12 vct/mastic Misc Flooring NF Non-Detected N/A Gypsum board/joint compound
Misc Int. Walls NF Non-Detected N/A
Rubber base/mastic Misc Int. Wall base NF Non-Detected N/A 2x2 ACT Misc Ceilings NF Non-Detected N/A Carpet mastic Misc Floors with carpet NF Non-Detected N/A
HVAC duct mastic Misc HVAC system NF Non-Detected N/A Gray 12x12 vct/mastic Misc Int. Floor NF Non-Detected N/A
Building 1005A
Building Description and Findings (Inspected 07-29-2024)
Building 1005A is a temporary modular office. The building is constructed with wood wall framing, metal siding, and rubber roof system. The interior has VCT flooring, gypsum board walls and ceilings and a forced air mechanical system.
C. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
12x12 VCT/Mastic Misc Int. Floors NF Non-Detected N/A Gypsum board/joint compound
Misc Int.
Walls/Ceilings
NF Non-Detected N/A
Textured gypsum board ceiling Misc Int. ceiling NF Non-Detected N/A
Asbestos Containing Materials
Building 1014
Building Description and Findings (Inspected 04-23-2024)
Building 1014 is a wood storage building that is currently in use. The building is constructed as a pole barn structure with wood walls and roof framing. The roof and exterior walls are clad with metal. There are no HVAC systems and the building is partially open from a damaged roof.
D. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Concrete expansion joint Surf. Interior conc.
Expansion joints
NF Non-Detected N/A
Coating on ext. metal wall panels
Misc Metal Wall panels on perimeter of building
NF 40% Chrysotile 3510SF
Coating on exterior metal wall panels
-Exterior caulking ground debris- approx. 5sf
Building 1306
Building 1306 is a wood maintenance/office building that is currently vacant. The building is constructed with wood/steel structure, interior wood/gypsum board walls, wood roof structure and asphalt shingle roof. HVAC is provided through wall units.
E. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc. Roof NF Non-Detected N/A Gypsum board/joint compound Misc Int. Walls NF Non-Detected N/A Gypsum board ceiling texture Surf. Int. Ceiling NF Non-Detected N/A 12x12 cream VCT/Mastic Misc. Int. Floors NF Non-Detected N/A Black rubber base/mastic Misc. Int. wall base NF Non-Detected N/A Gray rubber base/mastic Misc. Int. wall base NF Non-Detected N/A 2x2 ACT Ceiling Misc. Int. Ceiling NF Non-Detected N/A Gypsum board wall texture Surf. Int. Wall NF Non-Detected N/A
Based on the sample analysis, none of the materials sampled were found to be
Building 1742A
Building 1742A is a temporary modular office. The building is constructed with wood wall
F. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Tan vct/mastic Misc Int. Floors NF Non-Detected N/A Gypsum board/joint compound
Misc Int.
Walls/Ceilings
NF Non-Detected N/A
Rubber base/mastic Misc Int. Wall base NF Non-Detected N/A
Building 1742B
Building 1742B is a temporary modular office. The building is constructed with wood wall
G. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Tan vct/mastic Misc Int. Floors NF Non-Detected N/A Gypsum board/joint compound
Misc Int.
Walls/Ceilings
Building 1742C
Building 1742C is a temporary modular office. The building is constructed with wood wall
H. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Tan vct/mastic Misc Int. Floors NF Non-Detected N/A Gypsum board/joint compound
Misc Int.
Walls/Ceilings
Building AS251
Building Description and Findings (Inspected 08-12-2024)
Building AS251 is a temporary modular office. The building is constructed with wood wall framing, fiber cement siding, and rubber roof system. The interior has VCT flooring, gypsum board walls and ceilings and a forced air mechanical system.
I. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Gypsum board/joint compound Misc Int.
walls/ceilings
NF Non-Detected N/A
Gray rubber base/mastic Misc Int. wall base NF Non-Detected N/A Textured ceiling Surf. Int. ceilings NF Non-Detected N/A 12x12 dark gray vct/mastic Misc Int. Floors NF Non-Detected N/A 12x12 light gray vct/mastic Misc Int. Floors NF Non-Detected N/A Gray vinyl sheet floor/mastic Misc Int. Floors NF Non-Detected N/A Black rubber base/mastic Misc Int. wall base NF Non-Detected N/A
Building AS849
Building Description and Findings (Inspected 04-20-20)
Building AS849 is a vacant maintenance structure. The building is constructed with a slab on grade, metal building system, metal exterior walls and roof, wood interior walls with gypsum board. There is a masonry stem wall on the exterior of the building.
J. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
12x12 Beige VCT Misc Interior floor NF Non-Detected N/A Ext. Door/ Window Caulk
Misc Ext.
doors/windows
NF Non-Detected N/A
Acoustical Ceiling Misc Ceilings NF Non-Detected N/A Ext. Expansion Joint at Masonry
Misc Masonry walls on exterior
NF 2% Chrysotile 48LF asphalt shingles Misc Roof on lean to section
NF Non-Detected N/A
Rubber Base/ Mastic Misc Int. wall base NF Non-Detected N/A Drywall/ Joint Compound Misc Int. Walls NF Non-Detected N/A
Exterior expansion joints at masonry stem walls
-Drywall and joint material including skim coats of joint material, ceiling remnants in SW room at perimeter 2nd floor loft- 40SF
Building AS3450
Building Description and Findings (Inspected 07-18-24)
Building AS3450 is a decommissioned mechanical and storage building. The building is constructed with slab on grade, masonry bearing walls, steel structure, and a modified bitumen roof system.
K. Laboratory Results
Material Material Type
Location Friability Laboratory Result Approx.Quantity
Door/louver caulk Misc Ext. Doors NF Non-Detected N/A Mastic at lower wall flashing
Misc Exterior walls NF Non-Detected N/A
Caulk at pipe penetrations Misc Ext. Pipe penetration
NF Non-Detected N/A
Pipe insulation mastic Misc HVAC mastic NF Non-Detected N/A Concrete exp. Joint Misc Floor expansion joints
NF Non-Detected N/A
Flashing at doors Misc Exterior doors NF Non-Detected N/A Modified bitumen roof Misc Roof NF Non-Detected N/A
Building AS3540
Building Description and Findings (Inspected 08-12-24)
Building AS3540 is a vacant storage building. The building is constructed with slab on grade, masonry bearing walls, steel structure, and a standing seam roof system.
L. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Exterior caulk at flashing Misc Ext. flashing NF Non-Detected N/A Gypsum board/joint compound Misc Int.
Walls/Ceilings NF Non-Detected N/A
Window caulk Misc Ext. windows NF Non-Detected N/A
Building AS3906
Findings
A. Building Description and Findings (Inspected 11-04-21)
Building AS3906 is a maintenance building with cmu exterior walls, steel roof structure and a membrane roof over insulation.
Location Friability Laboratory Result Approx.Quantity
Spray Fireproofing Surf. Steel structures F Non-Detected N/A
Door Caulk Misc. Exterior doors NF Non-Detected N/A Membrane roof Misc. Roof NF Non-Detected N/A Flashing at Roof HVAC Misc. Roof NF Non-Detected N/A
Based on the sample analysis, none of the materials tested were found to be Asbestos
Building AS3990
Building Description and Findings (Inspected 08-12-2024)
Building AS3990 is a temporary modular office. The building is constructed with wood wall
M. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Gypsum board/joint compound Misc Int. Walls NF Non-Detected N/A Gray vct/mastic Misc Int. Floors NF Non-Detected N/A Exterior caulk Misc. Exterior caulking
Textured ceiling Surf. Int. Ceiling NF Non-Detected N/A
Structures H206, H207, H208, H209
Building Description and Findings (Inspected 07-18-2024)
Structures H206, H207, HG208, H209 are identical storage shelters with steel and wood framing, concrete slab, and asphalt shingle roof systems.
N. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A
Building LCH4034
Building LCH4034 is a vacant gas station. The building is constructed with brick exterior walls and interior wood/metal framing, vinyl siding, and asphalt shingle roof. The interior has VCT flooring, gypsum board walls and acoustical ceilings and a forced air mechanical system.
O. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
12x12 cream vct/mastic Misc Int. floors NF Non-Detected N/A Gypsum board/joint compound Misc Int. walls NF Non-Detected N/A Gray rubber base/mastic Misc. Int. rubber base NF Non-Detected N/A Exterior door/window caulk Surf. Exterior door/window caulk
NF Non-Detected N/A
Asphalt shingles/felt Misc. Roof NF Non-Detected N/A Building expansion joint at brick Misc. Exterior brick expansion joint NF Non-Detected N/A
Light brown rubber base/mastic Misc. Int. Wall base NF Non-Detected N/A 2x2 ACT Misc. Int. Ceiling NF Non-Detected N/A
Building RR27
Building RR27 is a vacant head structure. The building is constructed with a slab on grade, wood wall and roof framing, asphalt shingle roof, and wood/gypsum board interior walls.
P. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A Door caulk Misc Exterior Door NF Non-Detected N/A Window caulk Misc Exterior windows NF Non-Detected N/A
Gypsum board/joint compound
Misc Interior walls NF Non-Detected N/A
Based on the sample analysis, none of the sampled materials were found to be
-Exterior caulking at door perimeter (under existing) - 15LF
Building RR28
Building RR28 is a vacant head structure. The building is constructed with a slab on
Q. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A Door caulk Misc Exterior Door NF Non-Detected N/A Window caulk Misc Exterior windows
Gypsum board/joint compound
Misc Interior walls NF Non-Detected N/A
Based on the sample analysis, none of the sampled materials were found to be
-Exterior caulking at door perimeter (under existing) - 15LF
Building RR108
Building RR108 is a vacant telecom structure. The building is constructed with a slab on
R. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
12x12 cream vct/mastic Misc Int. Floor NF Non-Detected N/A Gray rubber base/mastic Misc Interior wall base NF Non-Detected N/A
2x4 ACT Misc Ceiling NF Non-Detected N/A Door caulk Misc Exterior Door NF Non-Detected N/A
Building SBB229
Building SBB229 is an abandoned shelter structure. The building consists of a concrete slab on grade, wood wall and roof structure, and asphalt shingle roof.
S. Laboratory Results
Material Material Type
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A
Structure SFC408
Building Description and Findings (Inspected 04-23-2024)
Structure SFC408 is a shelter structure. The structure consists of a concrete slab on grade, wood structure, and asphalt shingle roof.
T. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A
Structure SFC499
Structure SFC499 is a shelter structure. The structure consists of a concrete slab on
U. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Roof NF Non-Detected N/A
Structure SFC581
Structure SFC581 is a shelter structure. The structure consists of a concrete slab on
V. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Exterior door NF Non-Detected N/A
Structure ST13
Structure ST13 is a decommissioned communication tower. The structure consists of a concrete foundation and steel tower and miscellaneous steel storage structures within the perimeter fencing.
W. Laboratory Results
Location Friability Laboratory Result Approx.Quantity
Caulk at duct penetration Misc Exterior duct NF Non-Detected N/A
Building TC1003
Building Description and Findings (Inspected 08-12-24)
Building TC1003 is a vacant office building. The building is constructed with concrete foundation, CMU exterior walls, metal stud interior walls with gypsum board. The building has an standing seam metal roof system.
HVAC is provided through a forced air mechanical system.
Location Friability Laboratory Result Approx.Quantity
Exterior caulk at pilasters Misc Exterior masonry pilasters
NF 3% Chrysotile 50LF
Exterior window/door caulk Misc Exterior doors/windows
NF Non-Detected N/A
Exterior caulk at phone box Misc Exterior telecom box
NF Non-Detected N/A
2x2 ACT Misc Int. ceilings NF Non-Detected N/A Gypsum board/joint compound Misc. Int. walls NF Non-Detected N/A Brown rubber base/mastic Misc. Int. wall base NF Non-Detected N/A 12x12 cream vct/mastic Misc Int. Floors NF Non-Detected N/A
Exterior caulk at Pilasters
-Miscelaneous sealant at east side exterior phone box- approx..1SF
Structure VL61
Structure VL61 is a shelter structure. The structure consists of a concrete slab on grade, wood structure, and asphalt shingle roof.
X. Laboratory Results
Material Material Type
Location Friability Laboratory Result Approx.Quantity
Asphalt shingles/felt Misc Exterior door NF Non-Detected N/A
Disposal
A. In accordance with the NCHHCU regulations, asbestos containing materials (ACM) waste should be taken to an approved landfill. All demolition/renovation work must be performed in accordance with NESHAP asbestos regulations, 40CFR61, Subpart M, and OSHA Regulations 29 CFR 1926.1101. Any disturbance should be conducted in accordance with federal, state, and local regulations.
Recommendations
A. Any demolition/renovation work in which ACM is disturbed must be in compliance with, EPA, OSHA and the state of North Carolina regulations. Abatement work shall be conducted by NC Accredited asbestos workers under the supervision of a NC accredited asbestos supervisor. The contractor conducting asbestos abatement activities must notify the North Carolina Department of Health and Human Services (HHS) ten (10) days prior to the disturbance of ACM if it is friable and greater than or equal to 160 square feet, 260 linear feet or 35 cubic feet.
B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to be asbestos-containing until sampling by a state of North Carolina licensed Asbestos Building Inspector personnel and analysis by a NVLAP-Accredited and state of North Carolina licensed laboratory can be performed.
See attached for Accreditations, Asbestos Lab Results and Chain of Custody. If further information is required, please contact me at 1-252-636-8778
Report Prepared by:
Christopher B. Walker, AIA North Carolina Asbestos Inspector Accreditation# 12878 The Walker Group Architecture, Inc., PO Box 541, New Bern, NC 28560
EMSL Analytical, Inc.
706 Gralin Street Kernersville, NC 27284
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404336EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 07/29/2024 3:10 PM
Analysis Date:New Bern, NC 28563 08/05/2024
Collected Date:
Project: Building 114
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
01-VCT
022404336-0001
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Beige
Non-Fibrous
Homogeneous cream vct/mastic
01-Mastic
022404336-0001A
None DetectedNon-fibrous (Other)100%Cellulose<1%Yellow/Clear
Non-Fibrous
Homogeneous cream vct/mastic
02-VCT
022404336-0002
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray/Beige
Non-Fibrous
Homogeneous cream vct/mastic
02-Mastic
022404336-0002A
None DetectedNon-fibrous (Other)100%Cellulose<1%Yellow
Non-Fibrous
Homogeneous cream vct/mastic
022404336-0003
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
20%
10%
5%
65%
Cellulose<1%Gray/White/Beige
Non-Fibrous
Heterogeneous interior plaster
Composite Result, Texture, Skim Coat, & Rough Coat.
022404336-0004
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
5%
15%
10%
69%
Cellulose1%Gray/White/Rust
Non-Fibrous
Heterogeneous interior plaster
No Discernible Layers Present.
022404336-0005
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
1%
15%
10%
74%
Cellulose<1%Gray/White/Rust
Non-Fibrous
Heterogeneous interior plaster
No Discernible Layers Present.
022404336-0006
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
10%
15%
3%
72%
Cellulose<1%White
Non-Fibrous
Homogeneous interior plaster
No Discernible Layers Present.
022404336-0007
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
10%
20%
10%
60%
Cellulose<1%Gray/Tan/White
Non-Fibrous
Heterogeneous interior plaster
Composite Result, Texture, Skim Coat, & Rough Coat.
022404336-0008
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
10%
10%
80%
Cellulose<1%Gray
Non-Fibrous
Homogeneous interior plaster
Rough coat only.
022404336-0009
None DetectedQuartz
Ca Carbonate
Perlite
Non-fibrous (Other)
10%
20%
2%
68%
Cellulose<1%Gray/White
Non-Fibrous
Homogeneous interior plaster
Composite Result, Skim Coat, & Rough Coat.
022404336-0010
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
White
Non-Fibrous
Homogeneous
Eexterior window caulk
Initial report from: 08/05/2024 12:38:19
Page 1 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/5/2024 12:38 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404336EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404336-0011
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Cellulose<1%White
Non-Fibrous
Homogeneous
Eexterior window caulk
022404336-0012
None DetectedNon-fibrous (Other)100%Cellulose<1%Gray/Black/Yellow
Non-Fibrous
Heterogeneous rubber base/mastic
Composite Result, Cove Base & Mastic.
022404336-0013
None DetectedNon-fibrous (Other)100%Gray/Black/Beige
Non-Fibrous
Homogeneous rubber base/mastic
Composite Result, Cove Base & Mastic.
022404336-0014
None DetectedNon-fibrous (Other)84%Cellulose
Glass
15%
1%
Brown/Gray/White
Fibrous
Heterogeneous gypsum board/joint compound
Wall System Composite.
022404336-0015
None DetectedNon-fibrous (Other)97%Cellulose
Glass
2%
1%
Brown/Gray
Fibrous
Homogeneous gypsum board/joint compound
Only gypsum wallboard present
022404336-0016
None DetectedNon-fibrous (Other)97%Cellulose3%White
Non-Fibrous
Homogeneous
HVAC duct mastic
022404336-0017
None DetectedNon-fibrous (Other)97%Cellulose3%White
Non-Fibrous
Homogeneous
HVAC duct mastic
Analyst(s)
Nicole MacDowell (8)
Scott Combs (11)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 08/05/2024 12:38:19
Page 2 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/5/2024 12:38 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404335EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 07/29/2024 3:10 PM
Analysis Date:New Bern, NC 28563 08/02/2024 - 08/05/2024
Collected Date:
Project: Building 203
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404335-0001
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Glass
55%
5%
Gray/Tan
Fibrous
Heterogeneous
2x4 ACT
022404335-0002
None DetectedPerlite
Non-fibrous (Other)
30%
10%
Cellulose
Glass
55%
5%
Gray/Tan/White
Fibrous
Homogeneous
2x4 ACT
022404335-0003
None DetectedNon-fibrous (Other)100%Clear
Non-Fibrous
Homogeneous carpet mastic
022404335-0004
None DetectedNon-fibrous (Other)98%Cellulose
Synthetic
<1%
2%
Clear
Non-Fibrous
Homogeneous carpet mastic
022404335-0005
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
5%
65%
Tan/White
Non-Fibrous
Heterogeneous plaster perimeter walls
022404335-0006
None DetectedNon-fibrous (Other)100%Beige
Non-Fibrous
Homogeneous plaster perimeter walls
Mostly paint
022404335-0007
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
15%
20%
65%
Tan/White
Non-Fibrous
Heterogeneous plaster perimeter walls
This is a composite result of texture and rough coat.
022404335-0008
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
20%
10%
70%
Tan/White
Non-Fibrous
Heterogeneous plaster perimeter walls
This is a composite result of skim coat and rough coat.
022404335-0009
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
5%
65%
Tan/White
Non-Fibrous
Heterogeneous plaster perimeter walls
022404335-0010
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
20%
10%
70%
Gray/White
Non-Fibrous
Homogeneous plaster perimeter walls
This is a composite result of skim coat and rough coat.
022404335-0011
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
20%
10%
70%
Gray/White
Non-Fibrous
Homogeneous plaster perimeter walls
This is a composite result of skim coat and rough coat.
022404335-0012
None DetectedNon-fibrous (Other)90%Cellulose10%Brown/Gray
Fibrous
Heterogeneous gypsum board/joint compound
Gypsum board only
022404335-0013
None DetectedCa Carbonate
Non-fibrous (Other)
5%
90%
Cellulose5%Brown/Gray/White
Fibrous
Heterogeneous gypsum board/joint compound
Composite result, gypsum board and joint compound
022404335-0014
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
White
Non-Fibrous
Homogeneous ext. door/window caulk
Initial report from: 08/05/2024 12:37:27
Page 1 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/5/2024 12:37 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404335EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404335-0015
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Cellulose<1%White/Silver
Non-Fibrous
Homogeneous ext. door/window caulk
022404335-0016
3% ChrysotileNon-fibrous (Other)97%Gray/White
Non-Fibrous
Heterogeneous ext. textured concrete
022404335-0017
Not Submittedext. textured concrete
No sample in bag
022404335-0018
Positive Stop (Not Analyzed)ext. textured concrete
022404335-0019
None DetectedNon-fibrous (Other)65%Cellulose
Glass
30%
5%
Gray/Red/Black
Fibrous
Heterogeneous asphalt shingles/felt
This is a composite result of shingle and felt.
022404335-0020
None DetectedNon-fibrous (Other)65%Cellulose
Glass
30%
5%
Gray/Red/Black
Fibrous
Heterogeneous asphalt shingles/felt
This is a composite result of shingle and felt.
022404335-0021
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Non-Fibrous
Homogeneous roof caulk at exhaust board
022404335-0022
None DetectedNon-fibrous (Other)95%Cellulose5%Black
Non-Fibrous
Homogeneous roof caulk at exhaust board
Analyst(s)
Bobby Wheatley (12)
Nicole MacDowell (8)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 08/05/2024 12:37:27
Page 2 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/5/2024 12:37 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404334EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 07/29/2024 3:10 PM
Analysis Date:New Bern, NC 28563 08/02/2024 - 08/05/2024
Collected Date:
Project: buillding 203A
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404334-0001
Layer Not Presentext. door caulk
Empty Bag
022404334-0002
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Cellulose<1%White
Non-Fibrous
Homogeneous ext. door caulk
022404334-0003
None DetectedNon-fibrous (Other)94%Glass6%Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404334-0004
None DetectedNon-fibrous (Other)95%Cellulose
Glass
<1%
5%
Brown/Gray/Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404334-0005
2% ChrysotileCa Carbonate
Non-fibrous (Other)
15%
83%
Gray/White
Non-Fibrous
Homogeneous ext. textured concrete
022404334-0006
Positive Stop (Not Analyzed)ext. textured concrete
022404334-0007
Positive Stop (Not Analyzed)ext. textured concrete
Analyst(s)
Cameron Evans (2)
Scott Combs (2)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 08/05/2024 08:36:56
Page 1 of 1ASB_PLM_0008_0002 - 2.31 Printed: 8/5/2024 8:36 AM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404635EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 08/13/2024 12:30 PM
Analysis Date:New Bern, NC 28563 08/15/2024
Collected Date:
Project: Building 401
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404635-0001
None DetectedNon-fibrous (Other)95%Glass5%Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404635-0002
None DetectedNon-fibrous (Other)95%Glass5%Gray/Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404635-0003
None DetectedCa Carbonate
Non-fibrous (Other)
5%
80%
Cellulose15%White
Fibrous
Heterogeneous gypsum board/joint compound
Composite Result of Joint Compound & Gypsum Board.
022404635-0004
None DetectedCa Carbonate
Non-fibrous (Other)
5%
80%
Cellulose15%Brown/Gray/White
Fibrous
Heterogeneous gypsum board/joint compound
Composite Result of Joint Compound & Gypsum Board.
022404635-0005
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Tan
Non-Fibrous
Homogeneous athletic floor/mastic
Mastic Only.
022404635-0006
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Tan
Non-Fibrous
Homogeneous athletic floor/mastic
Mastic only
07-Floor Tile
022404635-0007
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous gray 12x12 vct/mastic
07-Mastic
022404635-0007A
None DetectedNon-fibrous (Other)100%Cellulose<1%Yellow
Non-Fibrous
Homogeneous gray 12x12 vct/mastic
08-Floor Tile
022404635-0008
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Gray
Non-Fibrous
Homogeneous gray 12x12 vct/mastic
08-Mastic
022404635-0008A
Insufficient Materialgray 12x12 vct/mastic
09-Floor Tile
022404635-0009
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Tan
Non-Fibrous
Heterogeneous cream 12x12 vct/mastic
09-Mastic
022404635-0009A
None DetectedNon-fibrous (Other)100%Cellulose<1%Tan
Non-Fibrous
Homogeneous cream 12x12 vct/mastic
10-Floor Tile
022404635-0010
None DetectedQuartz
Non-fibrous (Other)
20%
80%
Tan
Non-Fibrous
Homogeneous cream 12x12 vct/mastic
10-Mastic
022404635-0010A
None DetectedNon-fibrous (Other)100%Cellulose<1%Tan
Non-Fibrous
Homogeneous cream 12x12 vct/mastic
Initial report from: 08/15/2024 17:15:01
Page 1 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/15/2024 5:15 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404635EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
10-Leveler
022404635-0010B
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Gray
Non-Fibrous
Homogeneous cream 12x12 vct/mastic
022404635-0011
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Cellulose<1%Gray/Yellow
Non-Fibrous
Homogeneous black rubber base
/mastic
Composite Result of Cove Base & Mastic.
022404635-0012
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Cellulose<1%Gray/Yellow
Non-Fibrous
Heterogeneous black rubber base
/mastic
Composite Result of Cove Base & Mastic.
022404635-0013
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Cellulose<1%Gray/Tan
Non-Fibrous
Homogeneous gray sheet flooring/mastic
Composite Result of Flooring & Mastic
022404635-0014
None DetectedCa Carbonate
Non-fibrous (Other)
5%
95%
Gray
Non-Fibrous
Homogeneous gray sheet flooring/mastic
Mastic Insufficient
022404635-0015
2% ChrysotileCa Carbonate
Non-fibrous (Other)
10%
86%
Fibrous (Other)2%Gray/White
Non-Fibrous
Homogeneous ext.door/window caulk
022404635-0016
Positive Stop (Not Analyzed)ext.door/window caulk
022404635-0017
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
5%
65%
Gray/Tan/White
Non-Fibrous
Heterogeneous ext. stucco porch ceiling
022404635-0018
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
10%
5%
85%
Tan/White
Non-Fibrous
Heterogeneous ext. stucco porch ceiling
022404635-0019
None DetectedQuartz
Ca Carbonate
Non-fibrous (Other)
30%
10%
60%
Gray/Tan/White
Non-Fibrous
Heterogeneous ext. stucco porch ceiling
Analyst(s)
Cameron Evans (12)
Jurnee West (10)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 08/15/2024 17:15:01
Page 2 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/15/2024 5:15 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404634EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 08/13/2024 12:30 PM
Analysis Date:New Bern, NC 28563 08/15/2024
Collected Date:
Project: Building 401A
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404634-0001
None DetectedNon-fibrous (Other)95%Glass5%Gray/Black
Fibrous
Heterogeneous asphalt shingles/felt
Felt not present
022404634-0002
None DetectedNon-fibrous (Other)90%Glass10%Gray/Red/Black
Fibrous
Heterogeneous asphalt shingles/felt
Felt not present.
Analyst(s)
Cameron Evans (1)
Jurnee West (1)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Kernersville, NC NVLAP Lab Code 102104-0, Virginia 3333-000228, West Virginia LT000321
Initial report from: 08/15/2024 17:15:52
Page 1 of 1ASB_PLM_0008_0002 - 2.31 Printed: 8/15/2024 5:15 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404359EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Attention: Phone:Chris Walker (252) 636-8778
Fax:The Walker Group Architecture (252) 636-8992
Received Date:PO Box 541 07/29/2024 3:10 PM
Analysis Date:New Bern, NC 28563 08/02/2024
Collected Date:
Project: Building 528
Test Report: Asbestos Analysis of Bulk Materials via AHERA Method 40CFR 763 Subpart E
Appendix E supplemented with EPA 600/R-93/116 using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
022404359-0001
None DetectedPerlite
Non-fibrous (Other)
30%
15%
Cellulose
Glass
45%
10%
Tan
Fibrous
Heterogeneous
2x4 ACT
022404359-0002
None DetectedPerlite
Non-fibrous (Other)
30%
15%
Cellulose
Glass
45%
10%
Tan/White
Fibrous
Homogeneous
2x4 ACT
022404359-0003
None DetectedCa Carbonate
Non-fibrous (Other)
10%
88%
Cellulose
Glass
2%
<1%
Gray/White
Non-Fibrous
Heterogeneous
Gypsum board/joint compound
Composite Result of Joint Compound & Gypsum Board.
022404359-0004
Insufficient MaterialGypsum board/joint compound
Bag empty
022404359-0005
None DetectedNon-fibrous (Other)90%Cellulose10%Black
Fibrous
Heterogeneous int. perimeter wall exp.
022404359-0006
None DetectedNon-fibrous (Other)90%Cellulose10%Black
Fibrous
Heterogeneous int. perimeter wall exp.
022404359-0007
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Gray
Non-Fibrous
Homogeneous ext. window caulk
022404359-0008
None DetectedCa Carbonate
Non-fibrous (Other)
10%
90%
Gray
Non-Fibrous
Homogeneous ext. window caulk
022404359-0009
None DetectedNon-fibrous (Other)90%Glass10%Gray/Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404359-0010
None DetectedNon-fibrous (Other)90%Glass10%Gray/Black
Fibrous
Heterogeneous asphalt shingles/felt
No Felt Present.
022404359-0011
5% ChrysotileNon-fibrous (Other)95%Black
Non-Fibrous
Heterogeneous caulk at roof vent
022404359-0012
Positive Stop (Not Analyzed)caulk at roof vent
Initial report from: 08/02/2024 16:36:20
Page 1 of 2ASB_PLM_0008_0002 - 2.31 Printed: 8/2/2024 4:36 PM
Tel/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com / kernersvillelab@emsl.com
022404359EMSL Order:
Customer ID: WALK85
Customer PO:
Project ID:
Analyst(s)
Cameron Evans (6)
Jurnee West (4)
Stephen Bennett, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis .