N4008525B0015 Dwgs Signed.pdf
PDF 3 MB Posted
- Attached to
- Repair Heads Building 1826
- Solicitation number
- N4008526R9056
About this file
This document is a construction drawing set for renovation work at Marine Corps Base Camp Lejeune, North Carolina, specifically for Repair Heads Building 1826, Contract Number 25-0015.
The project encompasses comprehensive renovation and demolition of Building 1826's head facilities, including removal of existing metal stud walls, fixtures, and associated utilities, with replacement of plumbing, electrical, HVAC, and mechanical systems. Key renovation work includes new light gauge metal stud walls with moisture and mildew-resistant gypsum board, new plumbing fixtures (water closets, urinals, lavatories, showers, water heater, floor drains), new electrical circuits and lighting with occupancy sensors, waste and vent piping systems, and mechanical systems including exhaust fans and electric heaters. The drawings specify detailed finishing requirements including ceramic tile, signage (interior tactile room signs with braille), and compliance with ADA accessibility standards and Architectural Barriers Act requirements. Demolition notes require removal of existing plumbing fixtures, conduits, switches, and utilities; asbestos-containing materials and lead-based paint must be disposed of through the Camp Lejeune landfill by appointment. The construction documents include floor plans, demolition and renovation notes, building sections, door and frame details, toilet accessory schedules, ceiling framing plans, plumbing plans (domestic water, waste and vent, demolition), mechanical equipment schedules, electrical plans with lighting fixture and panelboard schedules, and complete electrical general notes addressing NEC compliance, device mounting heights, and installation requirements. All work must coordinate with existing systems and maintain building functionality during construction.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| N4008525B0015 Specs.pdf | ||
| 25-0015 Asbestos Report.pdf | ||
| RFP PDF.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S1828A
S1827A
S1847D S1847A
S1855
HP503
S1854A
HP576
S1854C
HP502
DUNCAN
S
T
Richlands
US 17
Beulaville
Burgaw
Words Corner
BoltonUS 7
4 &
Acme Delco
Leland
Warsaw
Magnolia
Rosehill
US 117
US 421
Wallace
CAMP LEJUENE
Swansboro
Hampstead
Wilmington
Scott Hill
US
A
A
L T
N T
I
C
Holly Ridge
NEW RIVER
Folkstone
Dixon
Jacksonville
Verona
GRAPHIC SCALE IN MILES
201010
Morehead City
A E
O C
N
Pink Hill
Mt. Olive
Seven Springs
Goldsboro US 70 New Bern
Havelock
NEUSE
Tuscarora
Trenton
Comfort
Kinston Dover
OAK GROVE
Pollacksville
Maysville
CHERRY POINT
US 70
RIVER
Otway
Beaufort
OLD LANDFILL POND
ORDE POND
S560
TBD
S1758
S1752A
S1144
S929
S1024
S1879
S1339
S1015A
S1115A
S906A
S1006A
S1006B S1301A
S496
S1318
S1404D
S1311B
S1828A
S1204A
SHP1018
S1827A
S1401A
S1308C
S1334
S555
S1352
S1025
SFC450
S1007
SFC222
SFC449
S1808E
SFC453
SFC454
SFC456
SFC455
SFC460
SFC438
PVH118D
PV227A
S960
SFC44
SFC389
SFC197
SFC257
S967B
SFC231
SFC42
S1843
CONT162
SFC59
SFC448
S1216
S1320
SFC272
SFC271
SFC254
SFC104
S1418
S1135
S1847D
S1767A
SFC149
PV128A
PVH118C
CONT160
S1877
S1767
S1767B
S567
SFC123
S969A
SFC269
S568
S569
S1832
SFC287
SFC468
S1740
S1324
SHP241
S1326
S1454
S44
S1833
SFC451
S1444
S1426
SFC388 SFC378
S1834
S1522A
S1835
S58N
S1878
SFC465
S1512
S1327
FC444
SFC463
S1325
S1017
SHP244
S566
S969B
S1754
S1838
SFC278
SFC244
SHP232B
SSH51
S1737
SFC466
S969C
SFC54
S1313
SFC265
SHP436
SFC267
S1422
SHP456
S1808E
SFC385
SFC230C
S1782
SHP493
SFC66M
S1221
S1847A
S1739
FC447
S1398
S1340A
SHP252
SFC219
SFC230B
SFC110
SFC345
SFC595
S1046C
SFC64C
SHP210A
SSH41
SFC252
S1510
SFC142
S1312A
SFC66N
S960
S956
S562
S775
S120
S932
S124
S563
S208
SFC299
PARADE FIELD
PARADE FIELD
S67
FC310
FC364
CTR11
HP155
HP135
SFC359
S1855
FC286
FC66A
FC280
HP250
FC285
HP237 1337
FC400
FC115
FC332
HP102
FC371
FC300
FC66
FC359
FC100
FC416
FC412
FC415
FC414
S962
FC65
HP131
FC500
FC308
FC356
D29
HP413
FC230
HP402
HP259
FC51
FC255
FC481
FC375
FC64
FC62
FC63
HP500
FC504
FC507
FC478
FC425
FC303
HP55
HP513
FC45
HP504
HP512
HP465
FC420
FC270
HP455
HP301
FC365
HP53
FC306
HP57
HP308
HP51
FC571
FC574
HP306
FC573
HP307
HP285
FC360
HP550
HP505
HP225
HP435
HP275
FC200
HP508
HP507
HP510
HP255
HP560
FC530
HP445
HP485
HP514
HP509
FC525
FC560
FC520
HP295
FC550
FC565
HP475
FC515
HP503
FC330
FC555
HP245
HP195
FC292
HP165
HP235
HP265
FC263
HP215
HP115
FC291
HP135
HP175
HP125
HP105
HP145
HP155
FC364
HP88
HP185
123A
223A
423A
FC57
FC130
FC127
1880A
FC128
FC129
FC281FC131
HP112
FC298
FC143
HP5
FC173
SSA11
SSA10
FC134
FC253
FC56
1121A
ES101
FC190
1775E
FC355
1775A
1775B
1775C
1775D
1450A
1450B
1450C
1775H
1829A
1829B 1775G
S1752
S1753
FC307
1121B
64A
59F
FC174
59E
FC250
FC50
FC206
1006D
59G
FC207
FC211
309E
235A
309D
309C
1337D
FC320
312E
FC370
SH49
64B
FC67
FC112
1121C
FC58
309F
S90
1701A
219B
219C
FC138
FC136
516A
SFC221
CTR121
FC137
FC310F
FC298A
FC310E
FC310C
FC310B
FC310D
HP155C
FC310G
HP155B
FC140
FC195
FC139
FC443
HP89
CTR149
58F58E
58H58G
CTR138
FC484
SSA1
SSA2
SSA3
FC442
236A
FC445
SFC499
FC101
FC201
FC102
S932
1250J
1250BF
1250L
1250BE
1250E
1250P
1250BB1250BC1250BD
1250D
1250C
1250B
1250K
1250H
1250R
1250Q1250AF1250AL
1250AE
1250AG
FC292F
FC551
FC531
FC566
FC358
HP1016
13A
SFC419
510A
510C
510B
1005G
59D
CTR124
309K
519F
519E
519A
519C
519D
519B
519H
320E
219F
519G
HP495C
905C
905B
HP135C
HP135D
HP495D
309N
CTR905
320B
320C
320D
219E
510E
FC467
516F
316C
219G
219D
CONT289
516E
510D
CTR139
312C
516D
516B
312D
516C
SH63
SH64
SH61
SH62
977B
977A
SSA4
SSA5
SSA6
227C
FC510
1323C
1323B
1323A
1450N
S125C
S125B
1450M
1005A
411C
CTR153
FC45C
1005H
SH60
1742A
SHP505B
S677
1742C
1742B
HP52
HP476
CTR521
CTR143
HP135F
S1220B
HP155F
HP135E
FC311A
HP495F
S579
HP495E
HP155D
HP155E
FC310A
HP135B
HP495G
HP155A
HP135G
HP305
HP495H
CTR905A
FC540
FC251
HP1017
FC120
S1854A
FC40
HP576
FC260
SH50
HP232
FC436
FC294
HP416
HP206
CTR133
FC241
FC362
FC293
FC441
FC230A
FC309B
FC375P
FC132
FC120A
FC375N
HP328
SFC143B
SFC143A
RNGD30
FC311C
FC311B
SFC211C
SFC211D
SFC255C
SFC255B
SFC263B
S1854B
FC354
S1854C
S691
HP502
751B
425C S1765B
HP56
S1765A
HP515
HP511
S1806
FC561
SFC290
FC556
FC382
SFC355A
SFC347
SHP88A
S1042A
SFC366
SHP494
FC286B
SFC66B
SFC66H
SSH12
SSH10
SSA11
SSA10
SHE1
SHE3
SHE5
SHE4 SHE7
SHE8
SHE2
SHE6
SSA1
SSA2
SSA3
SFA8
SFA9
SFA12
SFA10
SHE19
SHE17
SHE20
SHE18
SHE21
SSA4
SSA5
SSA6
SH63
SFA3
SFA4
SFA1
SFA2
SFD4
SFD6
SFD8
SFD5
SFD9
SFD7
SFD3
SFD2
SFD1
SFD11
SFD12
SFD10
SFD14
SFD13
SH22
SH13
GREENW
AY TRAIL
GREENWAY TRAIL
ALZ-5
ALZ-4
ALZ-6
ALZ-26
ALZ-33
TLZ PENGUIN
LO
UIS RD
N
ST
O S T
A ST
L S T
I S T
F ST
G ST
H ST
MCHUGH BLVD
M S
T
TURRET RD
HOPE RD
FIR ST
GONZALEZ BLVD W
TLZ PENG
UIN RD
CONNOR ST
MICHAEL RD
FAITH RD
HAMMOND RD
WEST RD
GUM ST
DUNCAN
S
T
DOGW
OOD ST
SIM
CENTER DR
F17 RANGE RD
CEDAR ST
CO
NN
EC
TO
R
RD
HEMLOCK ST
GIBB RD
EAST RD
VIRGINIA DARE DR
TACTICAL WAY
ASH ST
905 TANK TRL
ELM ST
CENTER RD
HICKORY ST
D
AL
Y R
D
MULBERRY ST
OLD BUS STATION ST
FRANKLIN
ST
914 TAN
K TR
L
O ST
FRANKLIN ST
DUNCAN ST
D ST
POST LN
8 R
D
G O
NZ
AL
EZ
L
O O
P
VIRTUE RD
C ST
B ST
REASONER ST
HONOR RD
CREEK RD
HM SMITH BLVD
LUCY BREW
ER AVE
BARKER ST
G O
N
ZA
LE
Z
BL
VD
E
M O
LLY PITC
H
ER
D
R
TL
Z
PE
NG
UI
N
LO
OP
ANDERSON ST
LO
G
IS
TI
C S
LN
FO
RTITUDE RD
G29 RANGE RD
DOG 11 TANK TRL
F6 RANGE RD
CONST. CONTR. NO.:
CONST. CONTR. NO.
FLOOR PLAN BUILDING 18261
DEMO FLOOR PLAN BUILDING 18262
RENO FLOOR PLAN BUILDING 18263
NORTH
NORTH
NORTH0 5'
1/4" = 1'-0"
10'
0 5' 1/4" = 1'-0"
10'
0 5' 10' 20' 1/8" = 1'-0"
Christopher Maas 30-Jun-2026
TOILET ACCESSORY PLAN1
TOILET FIXTURE/ACCESSORY MOUNTING HEIGHT DETAIL4
CEILING FRAMING PLAN2
FEMALE HEAD INTERIOR ELEVATIONS5
MALE HEAD INTERIOR ELEVATIONS6
0 1'
1/2" = 1'-0" 5'
0 1' 1/2" = 1'-0"
5'
0 5' 1/4" = 1'-0"
10'
0 5' 1/4" = 1'-0"
10'
NEW WORK DIMENSION PLAN3
0 5'
1/4" = 1'-0" 10'
NEW 58" MILDEW AND MOISTURE RESISTANT GYPSUM
BOARD, PAINT OPEN BAY SIDE; FRP TOILET SIDE
NEW HOLLOW METAL FRAME
NEW MTL STUDS @ 16" O.C. W/
R-15 BATT INSULATION
NEW DOOR AS
SCHEDULED
SEALANT AT ALL
EDGES,TYPICAL
HEAD
JAMB
SEALANT AT ALL
EDGES,TYPICAL
NEW DOOR AS
SCHEDULED
NEW MTL STUDS @ 16" O.C. W/
R-15 BATT INSULATION
NEW HOLLOW METAL FRAME
NEW 58" MILDEW AND MOISTURE RESISTANT GYPSUM
BOARD, PAINT OPEN BAY SIDE; FRP TOILET SIDE
CONST. CONTR. NO.
DOOR FRAME DETAIL2
BUILDING SECTION1
0 1'
1/2" = 1'-0" 5'
F1A B F2C F3
GENERAL NOTES - ROOFING:
1. ITEM LOCATION SUCH AS VENTS, GOOSENECKS, EQUIPMENT, TIE ANCHORS, ETC. IS APPROXIMATE. FIELD VERIFY
2. FIELD VERIFY VENT QUANTITIES
3. ALL FLASHING, COUNTER FLASHING, WOOD BLOCKING, WOOD NAILERS, AND RELATED ROOF ITEMS MUST BE REPLACED WITH NEW PER CONSTRUCTION DOCUMENTS
4. UNLESS OTHERWISE NOTED, ALL ROOF PENETRATIONS AND PLUMBING VENTS CURRENTLY LOCATED ON THE ROOF ARE TO REMAIN IN PLACE SUBSEQUENT TO NEW ROOF
INSTALLATION. REMOVE AND REPLACE ALL EXISTING FLASHING ELEMENTS AT ALL PENETRATIONS PRIOR TO NEW ROOFING SYSTEM INSTALLATION.
5. THE CONTRACTOR SHALL COORDINATE ALL UTILITY CONNECTIONS (PLUMBING, ELECTRICAL, HVAC, ETC.) WITH DEMOLITION AND RENOVATION PHASING. COORDINATE ALL
SHUTDOWNS AND/OR MODIFICATIONS OF EXISTING SYSTEMS WITH THE CONSTRUCTION MANAGER.
6. THE CONTRACTOR SHALL DE-ENERGIZE ALL ELECTRIC CIRCUITS PRIOR TO DEMOLITION OF AFFECTED EQUIPMENT, RE-CONNECT, AND RE-ENERGIZE ALL AFFECTED EQUIPMENT AND
ELECTRICAL DEVICES AS NECESSARY TO RETURN THEM TO WORKING CONDITIONS.
7. THE CONTRACTORS MAY ONLY USE THE CAMP LEJEUNE LANDFILL FOR THE DISPOSAL OF ASBESTOS CONTAINING MATERIALS, BUILDING PRODUCTS WITH TIGHTLY ADHERED LEAD
CONTAINING PAINT, NON-CONTAMINATED CLEAN DIRT AND CLEAN GRAVEL. THE HOURS OF OPERATION ARE 0730-1530. DELIVERY OF ACCEPTABLE MATERIALS (LEAD AND ASBESTOS) SHALL BE BY APPOINTMENT ONLY. APPOINTMENTS MADE BY PHONE AT 910-451-5011 OR 910-451-2946.
8. NON-CONTAMINATED MATERIALS (IDENTIFIED ABOVE): ALL OTHER CONTRACTOR GENERATED MATERIAL SHALL BE WEIGHED THROUGH THE BASE LANDFILL SCALES BEFORE BEING REMOVED FROM THE BASE. CONTRACTORS UTILIZING THE BASE SCALES WILL REQUIRE CONTRACTING OFFICER ASSISTED PRE-REGISTRATION WITH THE LANDFILL MANAGER. THE CONTRACTING OFFICER WILL REGISTER THE CONTRACT VIA E-MAIL, WITH THE BASE LANDFILL. ALL HAUL VEHICLES WILL MAINTAIN A SECURE VEHICLE PLACARD AS A CONDITION TO UTILIZE THE SCALE. E-MAIL THE CONTRACT INFORMATION TO THE LANDFILL CLERK, INCLUDING THE NAME ON THE PRIME CONTRACTOR, CONTRACT NUMBER, JOB NAME/DESCRIPTION, COMPLETION DATE AND WHETHER OR NOT ANY OF THE ABOVE MATERIALS WILL BE DELIVERED TO THE LANDFILL. HAULING AND OFF-BASE LANDFILL COSTS
SHALL BE INCLUDED IN THE CONTRACT.
SHOP DRAWING SUBMITTALS:
1. SHOP DRAWINGS MUST BE PROJECT-SPECIFIC
2. SHOP DRAWINGS MUST BE WELL COORDINATED AMONG THE VARIOUS VENDORS/TRADES/SUBCONTRACTORS THAT CONSTITUTE A PARTICULAR BUILDING SYSTEM
3. THE GOVERNMENT WILL REJECT INCOMPLETE SHOP DRAWINGS. COMPLETE SHOP DRAWINGS MUST SHOW ALL INTERFACING COMPONENTS. FOR EXAMPLE, ON BUILDING ENVELOPE
SYSTEMS:
a. OPENING PRODUCTS SUCH AS WINDOWS, DOORS, LOUVERS, PENETRATIONS, ETC. WITHOUT FLASHING, VAPOR BARRIER, THREE-PIECE SILL, INSULATION OF AIR SPACE, ETC., AND/OR
b. COMPONENTS SHOWN IN NON-PROJECT SPECIFIC WAY, AND/OR
c. COMPONENT LAYOUTS LABELED "ITEM BY OTHERS",
4. GOVERNMENT APPROVAL OF SHOP DRAWINGS DOES NOT RELIEVE THE CONTRACTOR OF THEIR RESPONSIBILITY TO PROVIDE THE CORRECT QUANTITIES, CAPABILITIES, PERFORMANCE, COORDINATION WITH ALL TRADES, TO PERFORM THOROUGH FIELD INVESTIGATIONS, TO PROVIDE COMPLETE SYSTEMS IN PLACE AND READY FOR USE IN
ACCORDANCE TO THE CONTRACT DOCUMENTS, REFERENCED CODES, GUIDELINES, ESTABLISHED GOOD PRACTICES, ETC.
SIGNAGE TYPE C
Interior Signage Schedule Signage Type Quantity Door
A 1 100a B 1 101a C 1 102a D 1 103a
SIGNAGE TYPE B
SIGNAGE TYPE A
SIGNAGE TYPE D
MISCELLANEOUS EXTERIOR ELEVATIONS:
1. REMOVE ALL DAMAGED MORTAR JOINTS (DOES NOT INCLUDE DEMOLISHED CONDITIONS SHOWN IN THE HATCHED AREAS). INFILL WITH NEW MORTAR TO MATCH EXISTING
CONDITIONS. FOR BIDDING PURPOSES ASSUME THAT 30 LF OR CMU JOINT MORTARS WILL NEED TO BE REPOINTED.
2. POWER WASH ALL CMU PRIOR TO PAINTING. SCRAPE/REMOVE LOOSE PAINT PRIOR TO PAINTING.
3. ACTUAL SAMPLES OF ALL THE EXTERIOR MATERIALS MUST BE SUBMITTED TO THE BEAP FOR REVIEW AND APPROVAL, NO EXCEPTIONS. COLOR CHIPS, PHOTOCOPIES, ELECTRONIC SAMPLES WILL NOT BE ACCEPTABLE
Additional Interior Signage Schedule Signage Type Quantity Location
E 2 Top of wall on exterior of heads
SIGNAGE TYPE E
T
T T
ELECTRICAL LEGEND
SYMBOL DESCRIPTION
HOME RUN CIRCUITS IN CONDUIT BACK TO PANEL BOARD; SIZED AS
INDICATED
EMERGENCY LIGHTING UNIT, 2-HEAD WITH BATTERY BACK-UP,
WALL MOUNTED, CONNECT TO NON-SWITCHED LEG. SEE DETAIL
NL-26 & LUMNINAIRE SCHEDULE.
RECEPTACLE, DUPLEX, 120VAC, 20A, UNLESS OTHERWISE NOTED.
SEE MOUNTING HEIGHT DETAIL THIS SHEET.
GFCI - GROUND FAULT CIRCUIT INTERRUPTER, 120VAC, 20A
WP - WEATHERPROOF GFCI 120VAC,20A
LIGHT FIXTURE. SEE LIGHTING FIXTURE SCHEDULE.
DISCONNECT SWITCH HEAVY DUTY, SIZE AS INDICATED ON
DRAWINGS
##A = DISCONNECT SIZE / # = NUMBER OF POLES / # = NEMA RATING,
/##AF = FUSE SIZE
30A/3/3R, W/ 30AF
480/277V
208/120V
PANELBOARD, SURFACE OR RECESSED MOUNTED AS SHOWN.
SIZE, RATINGS, AND MOUNTING AS INDICATED ON PANEL
SCHEDULE. CONTRACTOR IS RESPONSIBLE FOR REQUIRED
CLEARANCE IN FRONT OF ELECTRICAL PANEL. SEE NEC TABLE
110.26 WORKING SPACES FOR ADDITIONAL CLEARANCE
CONDITIONS.
MECHANICAL EQUIPMENT; TYPE AND CONNECTION AS INDICATED
DUAL TECHNOLOGY OCCUPANCY SENSOR
WALL SWITCH AT 46" AFF UNLESS OTHERWISE NOTED.
LOW VOLTAGE. ASSOCIATED WIRING IS TO BE PROVIDED BUT IS
NOT SHOWN ON DRAWINGS FOR CLARITY. PROVIDE SWITCHES
COMPATIBLE FOR LUMAIRES/LIGHTING SYSTEM. SEE OCCUPANCY
SENSOR DIAGRAMS (E-106).
S
SWITCHED LEG
NON-SWITCHED LEG
LV
ELECTRICAL GENERAL NOTES:
1. ALL ELECTRICAL WORK MUST BE IN FULL COMPLIANCE WITH NFPA 70 AND ALL
LOCAL CODES AND ORDINANCES AND IN ACCORDANCE WITH THE REQUIREMENTS
OF THE LOCAL AUTHORITY HAVING JURISDICTION.
2. ALL EQUIPMENT PROVIDED BY THE CONTRACTOR MUST BE LISTED AND LABELED
BY A NATIONALLY-RECOGNIZED TESTING AGENCY, ACCEPTABLE TO THE
AUTHORITY HAVING JURISDICTION, FOR THE CONDITIONS OF INSTALLATION. ALL
MATERIAL, EQUIPMENT AND DEVICES MUST BE NEW CURRENT PRODUCTS OF
MANUFACTURERS REGULARLY ENGAGED IN THE PRODUCTION OF SUCH
PRODUCTS. EQUIPMENT MUST BE SUITABLE FOR ITS APPLICATION (E.G. WHEN
INSTALLED OUTDOORS, IT MUST BE WEATHERPROOF, ETC.)
3. THE CONTRACTOR MUST REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR WORK
REQUIREMENTS, THE AMOUNT OF SPACE AVAILABLE FOR ELECTRICAL EQUIPMENT,
AND LAYOUT HIS WORK IN A COMPATIBLE AND FUNCTIONAL MANNER.
4. UNLESS SPECIFICALLY NOTED OTHERWISE, SYSTEMS PROVIDED OR INSTALLED BY
THE CONTRACTOR MUST BE COMPLETE AND FULLY-FUNCTIONING AFTER
INSTALLATION. INCIDENTAL COMPONENTS MAY NOT BE SHOWN, AND ALL WORK
WHICH MAY BE REASONABLY IMPLIED AS BEING INCIDENTAL TO THIS WORK, BUT
REQUIRED FOR THE PROPER OPERATION OF THE EQUIPMENT OR SYSTEM MUST BE
PROVIDED BY THE CONTRACTOR AND INCLUDED IN THE BID. ADDITIONAL CIRCUITS
MUST BE INSTALLED WHEREVER NEEDED TO CONFORM TO THE SPECIFIC
REQUIREMENTS OF EQUIPMENT.
5. TEMPORARY POWER CONNECTIONS AS REQUIRED MUST BE PROVIDED BY THE
CONTRACTOR AND INCLUDED IN THE BID. ALL TEMPORARY EQUIPMENT WIRING
MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE. THE
CONTRACTOR MUST PROVIDE DETAILS, METHODS, MATERIALS, ETC. FOR REVIEW
PRIOR TO MAKING TEMPORARY CONNECTIONS. FURNISH AND INSTALL ALL
EQUIPMENT AND MATERIALS INCLUDING CONTROL EQUIPMENT, MOTOR STARTERS,
BRANCH AND FEEDER CIRCUIT BREAKERS, PANELBOARDS, TRANSFORMERS, ETC.
FOR TEMPORARY POWER. COORDINATE WITH THE UTILITY PROVIDER AS
REQUIRED.
6. THE WORK MUST INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING AT
THE COMPLETION OF WORK AND ANY MINOR CORRECTIONS, CHANGES OR
ADJUSTMENTS NECESSARY FOR THE PROPER FUNCTIONING OF THE SYSTEM AND
EQUIPMENT.
7. ALL ELECTRICAL EQUIPMENT MUST, AT ALL TIMES DURING CONSTRUCTION, BE
ADEQUATELY PROTECTED AGAINST MECHANICAL INJURY, OR DAMAGE BY WATER
AND/OR THE ELEMENTS. ELECTRICAL EQUIPMENT MUST NOT BE STORED OUT OF
DOORS, BUT MUST BE STORED IN DRY PERMANENT SHELTERS. IF AN APPARATUS
HAS BEEN DAMAGED, OR HAS BEEN SUBJECT TO POSSIBLE INJURY BY WATER OR
THE ELEMENTS, SUCH DAMAGE MUST BE REPLACED AT NO ADDITIONAL COST.
8. DO NOT SCALE ELECTRICAL DRAWINGS. CONTRACTOR MUST FIELD VERIFY ALL
DIMENSIONS.
9. CIRCUIT LAYOUTS ARE NOT INTENDED TO SHOW THE NUMBER OF FITTINGS, OR
OTHER INSTALLATION DETAILS. UNLESS NOTED OTHERWISE, THE EXACT ROUTING
OF FEEDER AND BRANCH CIRCUIT RACEWAYS AND CABLES IS THE RESPONSIBILITY
OF THE CONTRACTOR. RISER AND GENERAL CIRCUIT ARRANGEMENTS ARE
SHOWN SCHEMATICALLY/DIAGRAMMATICALLY ONLY. THE CONTRACTOR MUST
ROUTE CONDUITS AS REQUIRED BY THE CONDITIONS OF THE INSTALLATION.
10. UNLESS DIMENSIONED, DEVICE LOCATIONS SHOWN ON THE DRAWINGS ARE
APPROXIMATE. ADJUST EXACT LOCATIONS AS REQUIRED TO SERVE THE INTENDED
PURPOSE AND TO AVOID CONFLICTS AND INTERFERENCES WITH OTHER TRADES.
IF NOT SHOWN ON THE ARCHITECTURAL DRAWINGS OR DIMENSIONED ON THE
ELECTRICAL DRAWINGS, VERIFY EXACT LOCATION WITH THE GOVERNMENT PRIOR
TO ROUGH-IN.
11. CONDUIT TERMINATING IN PRESSED STEEL BOXES MUST HAVE DOUBLE LOCKNUTS
AND INSULATED BUSHINGS. CONDUITS TERMINATING IN GASKETED ENCLOSURES
MUST BE TERMINATED WITH GROUNDING TYPE CONDUIT HUBS.
12. BRANCH CIRCUIT HOMERUNS SHOWN ON DRAWINGS INDICATE PHASE
CONDUCTORS, NEUTRAL, EQUIPMENT GROUND CONDUCTORS AS REQUIRED.
ADDITIONAL CONDUCTORS REQUIRED FOR CONTROL MUST BE INCLUDED EVEN IF
NOT EXPLICITLY SHOWN.
13. SEAL ALL CONDUIT OPENINGS THROUGH EXTERIOR BUILDING WALLS AND ROOF
WATERTIGHT.
14. IN WET LOCATIONS AND EXTERIOR, ALL WIRING DEVICES MUST BE
WEATHER-RESISTANT LISTED WITH WEATHERPROOF WHILE IN USE COVER.
15. RACEWAYS PENETRATING FLOORS, CEILINGS OR WALLS MUST BE PROPERLY
SEALED SMOKETIGHT.
16. ALL RACEWAYS MUST BE CONCEALED WHERE POSSIBLE.
17. INSTALL EXPOSED RACEWAYS PARALLEL TO OR AT RIGHT ANGLES TO NEARBY
SURFACES OR STRUCTURAL MEMBERS, AND FOLLOW THE SURFACE CONTOURS AS
MUCH AS POSSIBLE. NO DIAGONAL RUNS WILL BE ALLOWED. ALL CONDUITS MUST
BE RUN STRAIGHT WITH QUALITY WORKMANSHIP-LIKE MANNER. RUN PARALLEL OR
BANKED RACEWAYS TOGETHER ON COMMON SUPPORTS WHERE PRACTICAL.
MAKE BENDS IN PARALLEL OR BANKED RUNS FROM SAME CENTERLINE TO MAKE
BENDS PARALLEL.
18. PATCHING OF WATERPROOFED SURFACES MUST RENDER THE AREA OF THE
PATCHING COMPLETELY WATERPROOF.
19. ALL MOTORS AND OTHER VIBRATING EQUIPMENT MUST BE CONNECTED TO THE
CONDUIT SYSTEM BY MEANS OF A SHORT SECTION (18 INCH MINIMUM) OF FLEXIBLE
CONDUIT UNLESS OTHERWISE INDICATED. AN EQUIPMENT GROUNDING
CONDUCTOR MUST BE INSTALLED INSIDE THE FLEXIBLE CONDUIT AND TERMINATE
AT THE LOAD END WITH AN APPROVED GROUNDING CLAMP OR LUG.
20. SURFACE MOUNTED PANELBOARDS, JUNCTION, OUTLET AND PULL BOXES,
RACEWAYS, ETC., INSTALLED ON EXTERIOR SURFACES OR INSIDE ON EXTERIOR
WALLS MUST BE SUPPORTED BY SPACERS TO PROVIDE A MINIMUM 1/4" MINIMUM
CLEARANCE BETWEEN THE WALL AND EQUIPMENT.
21. TYPED PANELBOARD DIRECTORIES INSTALLED IN THE PANELBOARD DOOR POCKET
MUST REFLECT FINAL CONDITIONS AND ACTUAL ROOM NAMES AND NUMBERS IN
ADDITION TO THE GENERAL DESCRIPTION SHOWN ON THE PANEL SCHEDULES ON
THE DRAWINGS.
22. DO NOT PULL CONDUCTORS UNTIL THE CONDUIT SYSTEM IS COMPLETE IN EVERY
DETAIL. IN THE CASE OF CONCEALED WORK, "COMPLETE" MEANS UNTIL ALL
ROUGH PLASTERING OR MASONRY HAS BEEN COMPLETED.
23. WHERE SIZE IS NOT SHOWN ON THE DRAWINGS, BRANCH CIRCUITS MUST CONSIST
OF #12 OR #10 AWG MINIMUM PHASE, NEUTRAL AND EQUIPMENT GROUND
CONDUCTORS IN 3/4” MINIMUM RACEWAY.
24. USE #10 AWG CONDUCTORS FOR 20 AMPERE, 120 VOLT BRANCH CIRCUITS WITH A
TOTAL INSTALLED LENGTH GREATER THAN 75 FEET AND/OR BRANCH CIRCUIT
HOMERUNS LONGER THAN 50 FEET, I.E.; #12 AWG INCREASED TO #10 AWG FOR
RECEPTACLE BRANCH CIRCUITS OVER 75 FEET TOTAL LENGTH (INCLUDING THE
HOMERUN SEGMENT) AND HOMERUNS OVER 50 FEET. IF 277 VOLT CIRCUITS ARE
SHOWN, USE #10 AWG CONDUCTORS FOR 20 AMPERE, 277 VOLT BRANCH CIRCUITS
WITH TOTAL INSTALLED LENGTH GREATER THAN 200 FEET AND/OR BRANCH
CIRCUIT HOMERUNS LONGER THAN 125 FEET, I.E.; #12 AWG INCREASED TO #10
AWG FOR RECEPTACLE BRANCH CIRCUITS OVER 75 FEET TOTAL LENGTH
(INCLUDING THE HOMERUN SEGMENT) AND HOMERUNS OVER 50 FEET.
25. KEEP CONDUCTOR SPLICES TO A MINIMUM. INSTALL SPLICES AND TAPES THAT
POSSESS EQUIVALENT OR BETTER MECHANICAL STRENGTH AND INSULATION
RATINGS THAN CONDUCTORS BEING SPLICED. USE SPLICE AND TAP CONNECTORS
COMPATIBLE WITH CONDUCTOR MATERIAL. INSTALL CONDUCTORS AT EACH
OUTLET WITH AT LEAST 6 INCHES OF SLACK. CONNECT OUTLETS AND
COMPONENTS TO WIRING AND TO GROUND AS INDICATED AND INSTRUCTED BY
THE MANUFACTURER.
26. DO NOT SPLICE BRANCH CIRCUIT HOMERUNS WITHOUT THE PERMISSION OF THE
GOVERNMENT. HOMERUNS MUST BE CONTINUOUS FROM THE LAST OUTLET BOX
TO THE SERVING PANELBOARD.
27. DO NOT COMBINE BRANCH CIRCUIT HOMERUNS UNLESS SPECIFICALLY INDICATED
ON THE DRAWINGS.
28. INSTALL WIRING DEVICES AT HEIGHTS AS SHOWN ON THE DRAWINGS.
29. PROVIDE GROUND FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL IN
ACCORDANCE WITH THE NEC INCLUDING EXTERIOR RECEPTACLES AND
RECEPTACLES IN AREAS SUBJECT TO POSSIBLE WET CONDITIONS.
30. COORDINATE LOCATIONS OF MECHANICAL EQUIPMENT WITH THE RESPECTIVE
CONTRACTOR, VENDORS AND THE GOVERNMENT BEFORE ROUGH-IN. ADJUST
LIGHTING FIXTURES, RECEPTACLES AND ELECTRICAL EQUIPMENT TO
ACCOMMODATE THIS EQUIPMENT. ADVISE THE GOVERNMENT OF CONFLICTS
BEFORE ROUGH-IN.
31. BEFORE COMMENCING WORK OR ORDERING MATERIALS, THE CONTRACTOR MUST
COORDINATE WITH OTHER TRADES AND VERIFY THE NAMEPLATE RATINGS OF ALL
EQUIPMENT (MOTORS, HEATERS, COMPRESSORS, ETC.) AND ADJUST THE RATINGS
OF THE ELECTRICAL EQUIPMENT (SWITCHES, FUSES, CIRCUIT BREAKERS,
FEEDERS, ETC.) AS APPROPRIATE TO SERVE THIS EQUIPMENT.
32. ENERGIZE EQUIPMENT ONLY AFTER OBTAINING PERMISSION FROM THE
CONTRACTOR PROVIDING THE EQUIPMENT.
33. UNLESS SPECIFICALLY NOTED OTHERWISE, THE CONTRACTOR MUST MAKE FINAL
CONNECTIONS TO ALL UTILIZATION EQUIPMENT SHOWN ON THE DRAWINGS.
VERIFY THE TYPE OF FINAL CONNECTION AND PROVIDE APPROPRIATE WIRING
METHOD. THE CONTRACTOR MUST COORDINATE WITH THE MECHANICAL TRADE,
PRIOR TO ORDERING OR INSTALLATION OF ANY EQUIPMENT, TO VERIFY
MECHANICAL EQUIPMENT REQUIREMENTS ARE PROVIDED IN THE ELECTRICAL
DESIGN. THE CONTRACTOR WILL NOT BE COMPENSATED FOR COSTS ASSOCIATED
WITH CHANGING THE ELECTRICAL SYSTEMS TO MATCH UTILIZATION EQUIPMENT,
EVEN IF THE ELECTRICAL WORK IS INSTALLED PER THE ELECTRICAL DRAWINGS.
34. THE CONTRACTOR MUST COORDINATE ALL EQUIPMENT TERMINATIONS, PLUGS
AND CORDSETS WITH VENDOR EQUIPMENT AND VERIFY ALL DEVICE LOCATIONS
FOR SPECIALITY EQUIPMENT WITH CASEWORK PRIOR TO ROUGH-IN.
35. INSTALLATION INFORMATION PACKED WITH DEVICES AND EQUIPMENT MUST BE
RETAINED FOR INCLUSION IN THE OPERATIONS AND MAINTENANCE MANUALS.
36. THE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH THE
EXISTING ELECTRICAL SYSTEMS AND THE EXISTING BUILDING. THE SUBMISSION
OF THE PROPOSAL BY THE CONTRACTOR SHALL BE CONSIDERED EVIDENCE THAT
HE OR HIS REPRESENTATIVE HAS VISITED THE SITE AND BUILDINGS AND NOTED
THE LOCATION AND CONDITIONS UNDER WHICH THE WORK WILL BE PERFORMED
AND THAT HE TAKES FULL RESPONSIBILITY OF ALL FACTORS GOVERNING HIS
WORK. NO EXTRAS WILL BE CONSIDERED BECAUSE OF ADDITIONAL WORK
NECESSITATED BY EXISTING JOB CONDITIONS THAT ARE NOT INDICATED ON THE
DRAWINGS.
37. CONTRACTOR SHALL VERIFY ALL EQUIPMENT AND MECHANICAL CHARACTERISTICS
PRIOR TO BEGINNING WORK. CONTRACTOR SHALL MATCH ELECTRICAL
REQUIREMENTS AS REQUIRED BY MECHANICAL EQUIPMENT.
37. SAFETY
A. COMPLY WITH OSHA AND NEC ARC FLASH PROTECTION REQUIREMENTS.
B. FOR EQUIPMENT BEING REMOVED AND REPLACED, THE CONTRACTOR SHALL
DE-ENERGIZE THE EQUIPMENT AND MAKE IT SAFE PRIOR TO REMOVAL AND
COMPLY WITH OSHA REQUIREMENTS FOR LOCKING-OUT AND TAGGING
EQUIPMENT TO PREVENT INADVERTENT RE-ENERGIZING.
EXIT
FINISHED CEILING
FLOOR
DOOR
ABOVE COUNTER
RECEPTACLE/DATA3"
NOTE:
DETAIL SHOWN FOR REFERENCE ONLY, NOT ALL DEVICES ARE INDICATED ON PLANS.
BACK SPLASHSTRIKE SIDE
HINGE SIDE
COUNTER TOP
LIGHT SWITCH
/DIMMER
CABLE, VOICE/DATA, DUPLEX &
QUADRAPLEX RECEPTACLES
GANG
SWITCHING
MECHANICAL
CASETTE
CLOCK HANGER
RECEPTACLE
WALL MOUNTED EXIT SIGN
ABOVE DOOR (MAX. MT. HT. OF
80" ABOVE TOP OF DOOR)
6"6"
EQ
EQ
EQ.EQ.EQ.
ELECTRICAL DEVICES MOUNTING HEIGHT
CABLE TV
OUTLET
TV RECEPTACLE
A/V OUTLET
(HDMI)
LIGHTING PANEL, LIGHT POLE
LIGHTING
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MOTOR CIRCUIT PROTECTOR
MAIN DISTRIBUTION PANEL
MANUFACTURER
MANHOLE
MAIN LUGS ONLY
MOUNTED
MOUNTING
MANUAL TRANSFER SWITCH
MEDIUM VOLTAGE
NEUTRAL
NOT APPLICABLE
NORMALLY CLOSED
NATIONAL ELECTRIC CODE
NOT IN CONTRACT
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
POLE
PUBLIC ADDRESS
PULL BOX, PUSH-BUTTON
POWER FACTOR
PHASE
PROGRAMMABLE LOGIC CONTROLLER
PANEL
POWER PANEL, POWER POLE
PORTABLE POWER EQUIPMENT CABLE
POTENTIAL TRANSFORMER
POWER
RECEPTACLE
REQUIRED
RIGID GALVANIZED STEEL CONDUIT
ROOM
REMOTE TELEMETRY UNIT
DC MOTOR DRIVE
SHEET
SURGE PROTECTION DEVICE
SPECIFICATION
SELECTOR SWITCH
STAINLESS STEEL
SWITCH
SWITCHBOARD
SWITCH GEAR
TELEPHONE
TWISTED PAIR SHIELDED
TRANSIENT VOLTAGE SURGE SUPPRESSER
TYPICAL
UNDERGROUND
UNIT HEATER
UNLESS OTHERWISE NOTED
UTILITY
VOLTS
VARIABLE FREQUENCY DRIVE
WIRE, WATT
WATT-HOUR
WEATHERPROOF
WEATHERPROOF TELEPHONE ENCLOSURE
TRANSFORMER
EXISTING RELOCATED
A, AMP
AFF
AFG
AHU
AIC
ATS
AWG
BOF
BRKR
C, CND
CAB
CAT
CL
CB
CCTV
CKT
CLG
CP
CR
CS
CV
CT
CU
EF
EMER
EMT
ENCL
EQUIP
EWC
EWH
EPRF
FA
FAAP
FACP
FBO
FLA
FLUOR
FLR
FWE
GEN
G, GND
GFCI
HH
HID
HOA
HP
HPF
HPS
HTR
HV
Hz
IMC
INCAND
JB
K
KCMIL
KVA
KW
KWH
AMPERE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
AUTOMATIC TRANSFER SWITCH
AMERICAN WIRE GAUGE
BOTTOM OF FIXTURE
BREAKER
CONDUIT
CABINET
CATALOG
CHLORINE
CIRCUIT BREAKER
CLOSED CIRCUIT TELEVISION
CIRCUIT
CEILING
CONTROL PANEL
CONTROL RELAY, CORROSION RESISTANT
CONTROL SWITCH
CONTROL VALVE
CURRENT TRANSFORMER
COPPER
EXHAUST FAN
EMERGENCY
ELECTRICAL METALLIC TUBING
ENCLOSURE
EQUIPMENT
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
EXPLOSION PROOF
FIRE ALARM
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM CONTROL PANEL
FURNISHED BY OTHERS
FULL LOAD AMPS
FLUORESCENT
FLOOR
FURNISHED WITH EQUIPMENT
GENERATOR
GROUND
GROUND FAULT CURRENT INTERRUPTER
HANDHOLE
HIGH INTENSITY DISCHARGE
HAND-OFF-AUTO
HORSE POWER
HIGH POWER FACTOR
HIGH PRESSURE SODIUM
HEATER
HIGH VOLTAGE
HERTZ
INTERMEDIATE METALLIC CONDUIT
INCANDESCENT
JUNCTION BOX
THOUSAND
THOUSAND CIRCULAR MILLS
KILOVOLT AMPERE
KILOWATTS
KILOWATT-HOURS
LP
LTG
MCB
MCC
MCP
MDP
MFR
MH
MLO
MTD
MTG
MTS
MV
N / NEUT
NA
NC
NEC
NIC
NL
NO
NTS
P
PA
PB
PF
PH
PLC
PNL
P
PPE
PT
PWR
RECPT, RCP
REQ'D
RGS
RM
RTU
DCM
SH
SPD
SPEC
SS
SST
SW
SWBD
SWGR
TEL
TPS
TVSS
TYP
UGND
UH
UON
UTIL
V
VFD
W
WH
WP
WTE
XFMR
X/R
ABBREVIATIONS
os
G
FC
I
G
FC
I
G
FC
I
G
FC
I
SLV SLV
os os os os
30A/3/3R 30A/3/3R
G
FC
I
G
FC
I
SLV
W
AT
ER
-G
FC
I
MDP-32
MDP-30
MDP-49,51,53
MDP-52
MDP-54
MDP-44,46
MDP-48,50
MDP-25
MDP-31
CONST. CONTR. NO.
EXISTING 200A MDP PANELBOARD W/ 200 MCB. TYPE NQOD SERIES E2. 3 ɸ 4W
208Y/120V, TO REMAIN. PROVIDE NEW BREAKERS TO FEED CIRCUITS REQUIRED.
PROVIDE NEW GFCI RECEPTACLES & CIRCUIT(S) AS INDICATED. MIN. 2 - #12, 1 -
#12 EGC IN 1/2" C. FLUSH IN NEW WALLS.
PROVIDE NEW LUMINAIRES & CIRCUIT(S) AS INDICATED. SEE LIGHTING FIXTURE
SCHEDULE. MIN. 2 - #12, 1 - #12 EGC IN 1/2" C.
PROVIDE NEW CIRCUIT(S) TO EF-1 & EF-2 AS INDICATED. PROVIDE MINIMUM 2 - #12,
1 - #12 EGC IN 12"C.
PROVIDE NEW CIRCUIT(S) FOR ERH-1 & ERH-2. PROVIDE MINIMUM 2 - #10,
1 - #12 EGC IN 34" C. PROVIDE SAFETY DISCONNECT(S) AS REQUIRED.
PROVIDE NEW DUAL TECHNOLOGY OCCUPANCY SENSORS / LOW VOLTAGE
SWITCHING FOR LUMINAIRES AND EXHAUST FANS. LUMINAIRES AND EXHAUST
FANS MUST BE SWITCHED TOGETHER. SEE OCCUPANCY SENSOR DIAGRAM FOR
ADDITIONAL DETAILS.
PROVIDE NEW CIRCUIT TO WATER HEATER (WH-1). MIN. 3 - #6 - 1 #10 EGC IN 1 14" C.
PROVIDE NEW CIRCUIT HOMERUN(S) AND CONNECTION(S) TO EACH HARDWIRED
FLUSH, URINAL, AND LAVATORY CONNECTION (P1, P2, P3). MIN. 2 - #12, 1 -12 EGC
IN 12". COORDINATE WITH MECHANICAL SHEETS.
PROVIDE (2) 120V/20A WEATHER PROOF GFCI RECEPTACLES FROM PANELBOARD
MDP TO SUPPLY ASSE1060 HOT BOX/HEAT TRACE. COORDINATE WITH
MECHANICAL SHEETS & MANUFACTURER REQUIREMENTS. PROVIDE NEW 20A/1
BREAKERS. MIN. 2 - #12, 1 - #12 EGC IN 12"C. PROVIDE SELF REGULATING CABLE
CONNECTION, AS REQUIRED.
1. REMOVE LUMINAIRE(S), CONDUCTOR(S), SWITCH(ES), AND CONDUIT(S) SERVING
THE IDENTIFIED WORK AREA & AS REQUIRED TO COMPLETE NEW WORK. REMOVE
CONDUCTORS COMPLETE BACK TO PANELBOARD.
2. REMOVE RECEPTACLE(S), CONDUCTOR(S), AND CONDUIT(S) SERVING THE
IDENTIFIED WORK AREA. REMOVE CONDUCTORS COMPLETE BACK TO PANELBOARD.
3. REMOVE EXHAUST FANS AND RELATED MECHANICAL SERVING THE WORK AREA.
COORDINATE WITH MECHANICAL SHEETS.
4. EXISTING PANELBOARD TO REMAIN.
5. OTHER ELECTRICAL CONNECTIONS PASSING THROUGH THE WORK AREA ARE
PERMITTED TO BE RECONFIGURED BUT EXISTING FUNCTIONALITY MUST BE
MAINTAINED.
6. PRESERVE AND PROTECT ALL TELECOMMUNICATIONS.
A
A
B B
1. PROVIDE NEW LIGHTING PLAN AS INDICATED. SEE LIGHTING FIXTURE SCHEDULE &
LUMINAIRE PLATES. PROVIDE NEW CONDUCTORS IN CONDUIT TO CIRCUIT IN MDP
PANELBOARD.
2. PROVIDE NEW POWER PLAN AS INDICATED. PROVIDE NEW CONDUCTORS IN
CONDUIT TO CIRCUIT IN MDP PANELBOARD.
3. IF DRYWALL IS CUT OR DAMAGED IT MUST BE PATCHED AND RESTORED TO
ORIGINAL CONDITIONS. REPAINT ENTIRE ROOM TO MATCH EXISTING CONDITIONS.
GENERAL NEW WORK NOTES
KEYED NEW WORK NOTES
NEW WORK: LIGHTING AND POWER PLAN
DEMOLITION PLAN
DEMOLITION NOTES
2 2
SCALE: NTS
SCALE: NTS
CC
SURFACE LED WRAPAROUND
REVISED: NOVEMBER 2020 NL-3LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH REINFORCEMENT RIBS FOR
RIGIDITY; ENDCAPS SAME MATERIAL AS HOUSING, SECURED TABS, SCREWS, OR
RIVETS. SIZE AS INDICATED IN LUMINAIRE SCHEDULE.
2. OPTICS - ACRYLIC OR POLYCARBONATE LENS AS INDICATED IN LUMINAIRE
SCHEDULE.
3. LIGHT SOURCE - SOLID STATE LEDS, 3500K CCT UON, MINIMUM 80 CRI UON, AND
MINIMUM EFFICACY OF 110 LUMENS/WATT UON. INITIAL LUMEN OUTPUT AS
INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9
PF, OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, AND < 20% THD.
ON/OFF CONTROL AND FULLY DIMMABLE DOWN TO 10% MINIMUM OR AS
INDICATED IN LUMINAIRE SCHEDULE.
5. CERTIFICATION - UL LISTED FOR DAMP LOCATION, ROHS COMPLIANT, DLC
QUALIFIED. COMPLIES WITH IES LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - SURFACE MOUNTED.
7. OPTIONS - EMERGENCY BATTERY BACK-UP, INTEGRAL OCCUPANCY/VACANCY
SENSOR, VARIOUS SIZE AND OUTPUT OPTIONS.
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET
THE
SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR
PREFERENCE.
DIRECT WALL-MOUNTED LINEAR
REVISED: NOVEMBER 2020 NL-7LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - COLD ROLLED STEEL, EXTRUDED ALUMINUM, OR DIE CAST
ALUMINUM BODY WITH DIE CAST END CAPS AND STAINLESS STEEL HARDWARE.
SIZE AS INDICATED IN LUMINAIRE SCHEDULE.
2. OPTICS - REFRACTIVE LENS OPTIMIZED FOR ASYMMETRIC DISTRIBUTION.
3. LIGHT SOURCE - SOLID STATE LEDS, 3500K CCT UON, MINIMUM 80 CRI UON, AND
MINIMUM EFFICACY OF 85 LUMENS/WATT UON. INITIAL LUMEN OUTPUT AS
INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DIMMABLE DRIVER WITH
MINIMUM 0.9 PF, OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT,
AND < 20% THD. ON/OFF CONTROL AND FULLY DIMMABLE DOWN TO 10%
MINIMUM OR AS INDICATED IN LUMINAIRE SCHEDULE.
5. CERTIFICATION - UL LISTED FOR DAMP LOCATION, ROHS COMPLIANT. COMPLIES
WITH IES LM79, LM80 AND TM21 TESTING STANDARDS.
6. MOUNTING - WALL SURFACE MOUNTED
7. OPTIONS - EMERGENCY BATTERY BACK-UP, AND VARIOUS PROFILE DIMENSIONS
AND RUN LENGTHS. ALSO AVAILABLE WITH INDIRECT LIGHTING ELEMENT.
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET
THE
SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR
PREFERENCE.
CEILING OCCUPANCY/VACANCY SENSOR DIMMING DIAGRAM
OPERATION
1. BATHROOMS ROOMS MUST ILLUMINATE TO 100% PER OCCUPANCY SENSOR
SIGNAL.
2. AFTER 15 MINUTES OF VACANCY SENSING, LIGHT FIXTURES MUST TURN OFF.
LOAD SERVED
WIRE
SIZE
TRIP
POLE
CKT
NO. A
VA/PHASE
B C
CKT
NO.
TRIP
POLE
WIRE
SIZE LOAD SERVED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
1. HVAC EQUIPMENT SHALL USE TYPE HACR BREAKERS.
EXISTING PANELBOARD: MDP
TOTAL VOLT/AMPS
CONNECTED AMPS
#12
125A/3
20A/1
20A/1#12
20A/1#12 #1220A/1
BREAKERMAINWITH
ONLYLUGMAINWITH
XSQR.D-E2MFG
XLOAD
WIRE4Ø3
AMP200
AIC
RMSVOLT208Y/120
FLUSH
SURFACE
X
20A/1
20A/1 #1220A/1#12 20A/1 #1220A/1#12 20A/1 #1220A/1#12
20A/1 #1220A/1#12RECEPTACLES
HEATER
LIGHTING
20A/1#12 #1220A/1 20A/1#12 20A/1#12
#12
20A/1#12 20A/1 20A/1 20A/1 20A/1
#12 #12 #12 #12
#6
#1020A/2
200A
LIGHTING
LIGHTING
EXT.LIGHTING
FA.CTRLPNL
PTHP-1
FRIDGE
RECEPTACLES
HEATER
RECEPTACLES
LIGHTS
NMCI
NMCI
WATER-COOLER(NEW)
MARK DESCRIPTION SIZE/APERATURE VOLTS LAMPS WATTS COLOR
A
B
NL-3, SURFACE LED WRAP AROUND 2x4 120V
LED
3500K
4000 LUMN
NL-7, WALL MOUNTED LINEAR VARIES 103500K
800 LUMN
120V
WHITE
WHITE
LIGHTING FIXTURE SCHEDULE
NOTES
1. PANELBOARD SCHEDULE IS A REPRESENTATION OF EXISTING CONDITIONS.
FIELD VERIFY ALL CIRCUTS AND CONDITIONS BEFORE BEGINNING WORK.
2. PROVIDE NEW BREAKERS TO MATCH PANELBOARD AND CIRCUIT
REQUIREMENTS INDICATED.
3. COMPLETELY UPDATE PANELBOARD DIRECTORY INDICATING ALL NEW AND
EXISTING LOADS BEING SERVED.
4. UNUSED OR SPARE BREAKERS ARE PERMITTED TO BE REMOVED WHERE
SPACE IS REQUIRED FOR NEW CIRCUITS.
#1220A/1
EMERGENCY LIGHTING UNIT (ELU)
REVISED: NL-26LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - HIGH-IMPACT, UV-STABILIZED, INJECTION-MOLDED THERMOPLASTIC
HOUSING.
2. LIGHT SOURCE - SOLID STATE LEDS.
3. DRIVER - INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, AND < 20% THD.
ON/OFF CONTROL AND BATTERY BACKUP INTEGRAL TO UNIT.
4. CERTIFICATION - NFPA 101. UL LISTED FOR DAMP OR WET LOCATION, ROHS
COMPLIANT. COMPLIES WITH IES LM79, LM80 AND TM21 TESTING STANDARDS.
5. MOUNTING - WALL SURFACE MOUNTED.
6. OPTIONS - WHITE OR BLACK FINISH.
NOTE: THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT MAY MEET
THE
SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A CERTAIN MANUFACTURER OR
PREFERENCE.
NOVEMBER 2020
#1220A/2
C NL-26, EMERGENCY LIGHTING UNIT W/ AIMABLE HEADS VARIES 120V
LED
200 LUMN/HD
5 WHITE
LED HEATER
20A/1#12 20A/1#12
LOAD
LOAD
LOAD
LOAD
ASSE1660(NEW)
LOAD
LOAD
WH-1(NEW)
SUBPANEL-"A"
20A/3 LOAD
BTHRM-RECEPT.(NEW)
BTHRM-LIGHTS(NEW)
#1220A/2 FA.TRANSMITTER
FLUSH-SENSOR(NEW)
#1220A/2 HEATPUMP
HEATPUMP
POWER-POLES
#1220A/1 #1220A/1
50A/3
#1220A/1
ERH-1(NEW)
ERH-2(NEW)
EF-1(NEW)#1220A/1
#1220A/1 EF-2(NEW)
#1030A/2
#1030A/2
1/0
FA.CTRLPNL
| Sheets and Views |
| G-1 |
| 25-0015 Repair Heads Building 1826 (ArchDoneFinal)-A-104.pdf |
| Sheets and Views |
| A-4 |
| 25-0015 Repair Heads Building 1826 (ArchDoneFinal)-A-103.pdf |
| Sheets and Views |
| A-3 |
| 25-0015 Repair Heads Building 1826 (ArchDoneFinal)-A-102.pdf |
| Sheets and Views |
| A-2 |
| 25-0015 Repair Heads Building 1826 (ArchDoneFinal)-A-101.pdf |
| Sheets and Views |
| A-1 |
| M_P_1826-Model P601.pdf |
| Sheets and Views |
| Model |
| M_P_1826-Model p103.pdf |
| Sheets and Views |
| Model |
| M_P_1826-Model p102.pdf |
| Sheets and Views |
| Model |
| M_P_1826-Model p101.PDF |
| Sheets and Views |
| Model |
| M_P_1826-Model M101.pdf |
| Sheets and Views |
| Model |
| 25-0015 Repair Heads Building 1826 Electrical-E-103.pdf |
| Sheets and Views |
| E-3 |
| 25-0015 Repair Heads Building 1826 Electrical-E-102.pdf |
| Sheets and Views |
| E-2 |
| 25-0015 Repair Heads Building 1826 Electrical-E-101.pdf |
| Sheets and Views |
| E-1 |
| 2026-06-30T12:01:09-0400 | |
| MAAS.CHRISTOPHER.JETT.1588040727 |
File details come from the government source that posted it. Updated .