25-0015 Asbestos Report.pdf
PDF 33 KB Posted
- Attached to
- Repair Heads Building 1826
- Solicitation number
- N4008526R9056
About this file
This is an Asbestos Inspection Report for Building #1826 at MCB Camp Lejeune, dated December 16, 2025. The inspection determined that no asbestos-containing materials (ACM) were identified during the initial asbestos inspection, resulting in a hazard ranking of 0/BLUE with no further action required. The building, constructed in 1952 and occupied for general storage (GEN STG A/G/ORG), contained no friable or non-friable ACM records in the database at the time of the report.
The inspection documented ten samples collected on May 19, 2006, from various building locations including concrete expansion joint material, vinyl base and adhesive, drywall and joint material, interior and exterior caulking, gypsum board ceiling, and miscellaneous sealants. All samples tested negative for asbestos content (0% chrysotile, 0% amosite, 0% other asbestos types). The report specifies that ACM presents a health hazard only when asbestos fibers are airborne and inhaled, and directs building occupants to avoid disturbing materials. Maintenance and inspection protocols are outlined, including prohibition on sanding, grinding, or abrading materials, and requirements to report any damage or changes in material condition to the Camp Lejeune Asbestos Program Manager at (910) 451-5837.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFP PDF.pdf | ||
| N4008525B0015 Specs.pdf | ||
| N4008525B0015 Dwgs Signed.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT of:
Building # 1826
MCB CAMP LEJEUNE
Tuesday, December 16, 2025
Print Date
Tuesday, December 16, 2025 Page 1 of 4Print Date:
INSPECTION SUMMARY
BLDG #:
OCCUPANT:
YEAR BUILT:
BUILDING COMMENTS:
GEN STG A/G/ORG
HAZARD RANKING 0/BLUE; NO ACM IDENTIFIED [ AH MAY06 ]
NO ASBESTOS WAS IDENTIFIED DURING THE INITIAL ASBESOS INSPECTION. NO FURTHER ACTION REQUIRED
ASBESTOS MANAGER: 910-451-5837
Friable ACM(s) identified
Non-friable ACM(s) identified
Tested Non ACM or REMOVED Materials
DESCRIPTION LOCATION Date
ACM only presents a health hazard when asbestos fibers are airborne and inhaled.
Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.
HEALTH ASPECTS:
NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.
DESCRIPTION LOCATION Date Quantity
DESCRIPTION LOCATION Date Quantity
No friable ACM records found in database
No non friable ACM records found in database
NOTIFICATION OF ACM IN BUILDING
DRYWALL AND JOINT MATERIAL ENTRANCE 5/19/2006
EXTERIOR CAULKING, WINDOW 5/19/2006
MISCELLANEOUS SEALANT OUTSIDE OF BUILDING 5/19/2006
EXTERIOR CAULKING, WINDOW 5/19/2006
4" VINYL BASE AND ADHESIVE ENTRANCE 5/19/2006
CONCRETE EXPANSION JOINT MATERIAL OFFICE 5/19/2006
4" VINYL BASE AND ADHESIVE OFFICE 5/19/2006
INTERIOR CAULKING, WINDOW 5/19/2006
GYPSUM BOARD CEILING (WITH
ASSOCIATED JOINT COMPOUND)
OFFICE 5/19/2006
JOINT MATERIAL ENTRANCE 5/19/2006
Tuesday, December 16, 2025 Page 2 of 4Print Date:
ACM only presents a health hazard when asbestos fibers are airborne and inhaled.
Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.
Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.
CONDITIONS TO AVOID:
Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos
Program Manager.
REPORTS OF DAMAGE:
Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:
ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:
The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.
RECORDKEEPING:
CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837
Tuesday, December 16, 2025 Page 3 of 4Print Date:
SAMPLES COLLECTED
Sample Sample
Date
HA Sample Location Chr
Amo
Oth
Description
1826-01-01 5/19/200601 CENTER OF OFFICE 0 0 0CONCRETE EXPANSION
JOINT MATERIAL
1826-02-01 5/19/200602 NORTH DOORWAY 0 0 04" VINYL BASE AND
ADHESIVE
BROWN
1826-03-01 5/19/200603 NORTH DOORWAY 0 0 0DRYWALL AND JOINT
MATERIAL
WALL
1826-03-02 5/19/200603 NORTH CORNER OFFICE 0 0 0DRYWALL AND JOINT
MATERIAL
WALL
1826-04-01 5/19/200604 NORTH DOORWAY 0 0 0JOINT MATERIAL WALL , WHITE
1826-05-01 5/19/200605 NORTH CORNER OFFICE 0 0 04" VINYL BASE AND
ADHESIVE
GRAY
1826-06-01 5/19/200606 NORTH CORNER WALL 0 0 0INTERIOR CAULKING, GRAY @ WINDOW
1826-07-01 5/19/200607 NORTH CORNER OFFICE 0 0 0GYPSUM BOARD
CEILING (WITH
ASSOCIATED JOINT
COMPOUND)
1826-08-01 5/19/200608 NORTH WINDOW 0 0 0EXTERIOR CAULKING, WHITE , @ AC UNIT
BELOW WINDOW
1826-09-01 5/19/200609 NORTH DRAIN TUBE 0 0 0MISCELLANEOUS
SEALANT
EXTERIOR, WHITE @
PVC DRAIN TUBE
1826-10-01 5/19/200610 EAST WINDOW 0 0 0EXTERIOR CAULKING, WHITE, @ 6"X6" POWER
VENT/ FAN
Tuesday, December 16, 2025 Page 4 of 4Print Date: