This package includes structural interior design drawings and specifications for a boat maintenance facility project for the Department of the Navy. The drawings show proposed signage, furniture plans, floor finishes, and interior finish schedules. The signage drawings include schedules and details for room identification and directional signs. The furniture plans depict proposed furniture, fixtures and equipment for areas including a high bay, office option, and restroom option. Additional drawings illustrate proposed flooring materials for these areas as well as finish schedules designating proposed paints, wall and floor coverings. Specifications in the package provide further description and locations for proposed interior elements and finishes.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Q-1344
SOF BOAT MAINTENANCE AND
STORAGE FACILITY
NAS OCEANA, OWLS CREEK, VIRGINIA BEACH, VA
FINAL STRUCTURAL INTERIOR DESIGN PACKAGE
May 5, 2023
TABLE OF CONTENTS
1. STRUCTURAL INTERIOR DESIGN (SID) NARRATIVE
2. POINT OF CONTACT LIST
3. PLANS
4. FINISH BOARD
P-1344
STRUCTURAL INTERIOR
DESIGN (SID)
NARRATIVE
P‐1344
The SID (Structural Interior Design) package and the FF&E (Furniture, Fixtures, & Equipment) package will be fully coordinated with one another, as well as with the building support systems, in order to create a cohesive final design.
Barrier-free design features will be incorporated to comply with the most stringent requirements by the Architectural Barriers Act (ABA) Standards.
Sustainability focused design features will be included to comply with UFC 1-200-02.
Durable, low maintenance interior finishes will be used throughout the facility for ease of maintenance. The floor surface throughout the High Bay and utility rooms (Electrical, Compressor, and Mechanical) will receive sealed concrete. The Office and Restroom Options will received a 5-part resinous epoxy flooring system.
Wall finishes for the high Bay will be the standard PEMB interior wall finishes. All interior spaces (Electrical, Compressor, Mechanical, and Office Option) will receive painted impact resistant gypsum wall board (GWB). Restroom option will receive a porcelain wall tile wainscot with moisture resistant gypsum wall board above and epoxy paint. All interior exposed surfaces including metal frames, grilles, registers, diffusers, access panels, and panel boxes will be painted to match the adjacent wall or ceiling surface, excepting factory finished items.
Ceilings in the Office Option will be acoustical ceiling tile (ACT). GWB ceilings finished with epoxy paint will occur at the Electrical, Compressor, Mechanical and Restroom Option. Exposed ceiling in the High Bay.
Casework in the office will receive high pressure plastic laminate cabinetry and solid surface counters.
Interior building signage will align with the Signage UFC and ABA Guidelines.
POINTS OF CONTACT
POINTS OF CONTACT LIST
ACTIVITY REPRESENTATIVE
Nelvin J. Omandan General Engineer
NSWDG
757-862-9039 nelvin.j.omandan.civ@socom.mil
PROJECT MANAGER
Beth White Phone: 214-868-6409 Elizabeth.a.white136.civ@us.navy.mil
DESIGN MANAGER
Lawrence E. Johns Phone: 757-341-2054 lawrence.e.johns4.civ@us.navy.mil
INTERIOR DESIGNER
Ann Perry Phone: 757-341-0141 virginia.b.perry.civ@us.navy.mil
PLANS
CL
EQ EQ
CL
1 2 3
NOTE: MOUNT ON LATCH SIDE OF DOOR OR
ADJACENT WALL.
NOTE: MOUNT ON CENTER OF DOOR. NOTE: MOUNTING HEIGHT FOR
LOCATIONS WITHOUT DOORS
9"
TEXT
TEXT
MINIMUM HEIGHT - 4'-0" FROM
BASELINE OF LOWEST TACTILE
CHARACTER
MAXIMUM HEIGHT - 5'-0" FROM
BASELINE OF HIGHEST TACTILE
CHARACTER
4'- 0"
5'- 0"
TEXT
TEXT
SIGNS WITH TACTILE LETTERS ARE PERMITTED ON
THE PUSH SIDE OF DOORS WITH CLOSERS AND
WITHOUT HOLD-OPEN DEVICES WHEN NO WALL
SPACES ARE AVAILABLE.
ELECTRICAL
ROOM
NAME
REMOVABLE END CAPS
3" 2"
9"
TEXT: 1-1/2" TACTILE ROOM NUMBER WITH
GRADE 2 BRAILLE HELVETICA NEUE 55
ROMAN
TEXT: 3/4" TACTILE ROOM NAME,
HELVETICA NEUE 55 ROMAN
9"
3" 6"
9"
TEXT: 1-1/2" TACTILE ROOM NUMBER WITH
GRADE 2 BRAILLE HELVETICA NEUE 55
ROMAN
TEXT: 3/4" PRINTED PAPER ROOM NAME,
HELVETICA NEUE 55 ROMAN
SIGN TYPE A
SIGN TYPE C
NO SMOKING
9"
SIGN TYPE K
TEXT: 1-1/2" TACTILE ROOM NUMBER WITH
GRADE 2 BRAILLE HELVETICA NEUE 55
ROMAN3"
9"
SIGN TYPE BREMOVABLE END CAPS
REMOVABLE END CAPS
TEXT: 5/8" TACTILE MESSAGE
W/ GRADE 2 BRAILLE
HELVETICA NEUE 55 ROMAN
3"
9"
REMOVABLE END CAPS
SIGN TYPE Q
EXIT ONLY
UNISEX
101 TEXT: 1-1/2" TACTILE MESSAGE WITH GRADE 2
BRAILLE HELVETICA NEUE 55 ROMAN
TEXT: RAISED PICTOGRAM
TEXT: 3/4" TACTILE ROOM NAME WITH GRADE
2 BRAILLE HELVETICA NEUE 55 ROMAN3"
8" 3"
1'- 2"
11"
SIGN TYPE R
REMOVABLE END CAPS
SIGN TYPE T
8 1/2"
6"
FIRE
EXTINGUISHER
1" 1"
FIRE
EXTINGUISHER
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:2
0:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-A -R
_v irg in ia .p er ry
.rv t
AG601
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
SI
G
N
AG
E
SC
H
ED
U
LE
S
AN
D D
ET
AI
LS
CM
12885658
AP AP
EAW/LEJ
1707671
VI
R
G
IN
IA
B
EA
C
H , V
IR
G
IN
IA
N
AS
O C
EA
N
A, O
W
LS
C R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
AG
SIGNAGE SCHEDULE
ROOM LOCATION
SIGN TYPE SIGN TEXT QTY
DOORWAY
LOCATION NOTESNO. NAME
101 HIGH BAY TYPE Q 2 3
101 HIGH BAY TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE
EXTINGUISHER
102 ELECTRICAL TYPE A 1 2 EXTERIOR
102 ELECTRICAL TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE
EXTINGUISHER
103 SECURITY
ROOM
TYPE A 1 2
104 COMPRESSO
R
TYPE A 1 2
104 COMPRESSO
R
TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE
EXTINGUISHER
105 MECHANICAL TYPE A 1 2 EXTERIOR
105 MECHANICAL TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE
EXTINGUISHER
106 RESTROOM TYPE R 1 2
107 OFFICE TYPE C 1 2
GENERAL SHEET NOTES
SCALE: 3/4" = 1'-0"A1 SIGNAGE DOORWAY LOCATIONS
SCALE: 3" = 1'-0"C1 SIGNAGE TYPICAL DETAILS
1 ALL SIGN TYPES, TEXT, AND ROOM NUMBERS MUST BE VERIFIED WITH END
USER AND APPROVED BY CONSTRUCTION MANAGER PRIOR TO FABRICATION
2 THE LOCATION OF SIGNS AS NOTED ON THIS SHEET IS FOR GENERAL
REFERENCE ONLY AND IN SOME CASES IS NOT REPRESENTATIVE OF THE
EXACT FINAL LOCATION. LOCATIONS OF SIGNS SHALL BE DETERMINED IN
COORDINATION WITH THE PROJECT ARCHITECT AND THE CONSTRUCTION
MANAGER AT THE SITE. SIGN FABRICATOR MUST ARRANGE FOR MEETING AT
THE SITE TO COORDINATE AND CONFIRM FINAL SIGNAGE LOCATIONS
3 SIGNAGE MUST BE FABRICATED AND INSTALLED TO MEET ABA
REQUIREMENTS WITH REGARD TO BRAILLE, RAISED CHARACTERS, FINISHES
(CONTRAST), SIZE AND MOUNTING HEIGHT
5 MOUNTING OF SIGNAGE MUST BE BY MECHANICAL FASTENERS
6 UNLESS OTHERWISE NOTED, SIGNS ARE FOR INTERIOR USE
7 SIGNAGE FINISHES ARE AS LISTED ON SHEET IN601
SY
M
D E S
C R
IP
TI
O N
D
AT
E
AP
PR
HIGH BAY
MECHANICAL
COMPRESSOR
SECURITY ROOM
ELECTRICAL
M06
M06
S01
S02 A01
OFFICE
OPTION
RESTROOM
OPTION
IF402
B2
IF401
B2
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IF101
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FU
R
N
IT
U R
E
PL
AN
JW
12885659
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IF
SCALE: 1/8" = 1'-0"
FURNITURE PLAN
PLAN
NORTH
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED
FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT
PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS
WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO
THE CONSTRUCTION CONTRACT.
2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR
MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,
STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,
AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT.
FF&E SCHEDULE
MARK NAME
A01 CLOCK WALL-MOUNT 12" DIAMETER
C01 UPHOLSTERED TASK CHAIR WITH ARMS
D01 30X54 SIT/STAND DESK
M01 REFRIGERATOR, NO ICE MAKER
M02 COUNTERTOP MICROWAVE
M03 COFFEE BREWER -1 BURNER, NON-PLUMBED
M04 TRASH CAN 14"L x 10"D x 14"H
M05 SHOWER CURTAIN
M06 55 GALLON TRASH CAN WITH LID
S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H
S02 MRV STORAGE RACK
T01 42" DIA ROUND TABLE
1/8" = 1'-0" 4' 8' 16'0'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
M05M05
RESTROOM
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IF401
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FU
R
N
IT
U R
E
PL
AN
, R
ES
TR
O O
M
O
PT
IO
N
JW
12885660
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IF
SCALE: 3/8" = 1'-0" (IF101)B2 FURNITURE PLAN - RESTROOM OPTION
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
FF&E SCHEDULE
MARK NAME
A01 CLOCK WALL-MOUNT 12" DIAMETER
C01 UPHOLSTERED TASK CHAIR WITH ARMS
D01 30X54 SIT/STAND DESK
M01 REFRIGERATOR, NO ICE MAKER
M02 COUNTERTOP MICROWAVE
M03 COFFEE BREWER -1 BURNER, NON-PLUMBED
M04 TRASH CAN 14"L x 10"D x 14"H
M05 SHOWER CURTAIN
M06 55 GALLON TRASH CAN WITH LID
S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H
S02 MRV STORAGE RACK
T01 42" DIA ROUND TABLE
1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED
FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT
PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS
WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO
THE CONSTRUCTION CONTRACT.
2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR
MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,
STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,
AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT.
3/8" = 1'-0" 0' 2' 4' 6'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
A01
D01C01
M04
C01 D01
M04
T01C01
C01
M01
M03 M02
OFFICE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IF402
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FU
R
N
IT
U R
E
PL
AN
O
FF
IC
E
O
PT
IO
N
JW
12885661
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IF
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
SCALE: 3/8" = 1'-0" (IF101)B2 FURNITURE PLAN - OFFICE OPTION
FF&E SCHEDULE
MARK NAME
A01 CLOCK WALL-MOUNT 12" DIAMETER
C01 UPHOLSTERED TASK CHAIR WITH ARMS
D01 30X54 SIT/STAND DESK
M01 REFRIGERATOR, NO ICE MAKER
M02 COUNTERTOP MICROWAVE
M03 COFFEE BREWER -1 BURNER, NON-PLUMBED
M04 TRASH CAN 14"L x 10"D x 14"H
M05 SHOWER CURTAIN
M06 55 GALLON TRASH CAN WITH LID
S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H
S02 MRV STORAGE RACK
T01 42" DIA ROUND TABLE
1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED
FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT
PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS
WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO
THE CONSTRUCTION CONTRACT.
2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR
MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,
STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,
AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND
EQUIPMENT.
3/8" = 1'-0" 0' 2' 4' 6'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
OFFICE
OPTION
RESTROOM
OPTION
IN402
B2
IN401
B2
FLOOR FINISH LEGEND
SEALED CONCRETE
RESINOUS EPOXY
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IN101
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FL
O
O R
F
IN
IS
H
P
LA
N
JW
12885662
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IN
SCALE: 1/8" = 1'-0"
FLOOR FINISH PLAN
PLAN
NORTH
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND
SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF
CONSTRUCTION (OICC).
2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY
COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE
LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE
SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE
REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE
NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING
OFFICER.
3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.
IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN
TIME TO AVOID DELAYS.
4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND
CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF
THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN
THE CENTER OF A WALL.
5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION
JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY
BRUSH ARE NOT ACCEPTABLE.
6 TRANSITIONS MUST MEET ABA GUIDELINES.
7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER
DOOR.
8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS
THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A
COMPLETE INSTALLATION.
9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER
GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED
STONE WALLS.
10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED
ON EACH WALL.
1/8" = 1'-0" 4' 8' 16'0'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
FLOOR FINISH LEGEND
SEALED CONCRETE
RESINOUS EPOXY
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IN401
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FL
O
O R
F
IN
IS
H
P
LA
N
R
ES
TR
O
O M
O
PT
IO
N
JW
12885663
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IN
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND
SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF
CONSTRUCTION (OICC).
2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY
COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE
LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE
SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE
REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE
NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING
OFFICER.
3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.
IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN
TIME TO AVOID DELAYS.
4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND
CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF
THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN
THE CENTER OF A WALL.
5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION
JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY
BRUSH ARE NOT ACCEPTABLE.
6 TRANSITIONS MUST MEET ABA GUIDELINES.
7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER
DOOR.
8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS
THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A
COMPLETE INSTALLATION.
9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER
GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED
STONE WALLS.
10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED
ON EACH WALL.
SCALE: 3/8" = 1'-0" (IN101)B2 FLOOR FINISH PLAN - RESTROOM OPTION
3/8" = 1'-0" 0' 2' 4' 6'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
FLOOR FINISH LEGEND
SEALED CONCRETE
RESINOUS EPOXY
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
2:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IN402
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
FL
O
O R
F
IN
IS
H
P
LA
N
O
FF
IC
E
O
PT
IO
N
JW
12885664
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IN
GENERAL SHEET NOTES
GRAPHIC SCALE(S)
1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND
SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF
CONSTRUCTION (OICC).
2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY
COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE
LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE
SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE
REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE
NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING
OFFICER.
3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.
IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN
TIME TO AVOID DELAYS.
4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND
CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF
THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN
THE CENTER OF A WALL.
5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION
JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY
BRUSH ARE NOT ACCEPTABLE.
6 TRANSITIONS MUST MEET ABA GUIDELINES.
7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER
DOOR.
8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS
THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A
COMPLETE INSTALLATION.
9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER
GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED
STONE WALLS.
10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED
ON EACH WALL.
SCALE: 3/8" = 1'-0" (IN101)B2 FLOOR FINISH PLAN - OFFICE OPTION
3/8" = 1'-0" 0' 2' 4' 6'
SY
M
D E S
C R
IP
TI
O N
D
AT
E
TOP OF CONCRETE
FLOOR SLAB
T1
EXTERIOR DOOR
SEALED
CONCRETE
ALUMINUM THRESHOLD
EPOXY
RESINOUS EPOXY BASE TO RESINOUS EPOXY FLOORING - TYPICAL
W
AL
L
SCHLUTER; STYLE: RONDEC-DB; SATIN
NICKEL ANODIZED ALUMINUM
RESINOUS EPOXY FLOORING/BASE TO PORCELAIN WALL TILE - TYPICAL
RESINOUS EPOXY BASE
W
AL
L
FLOOR RESINOUS EPOXY FLOORING
INTEGRAL COVE
METAL TRANSITION STRIP
PORCELAIN WALL TILE
RESINOUS EPOXY BASE
RESINOUS EPOXY FLOORING
INTEGRAL COVE
FLOOR
PORCELAIN
WALL TILE
PORCELAIN
WALL TILE
SCHLUTER; STYLE: DILEX
AHK; SATIN NICKEL ANODIZED ALUMINUM
(W/ MATCHING INSIDE/OUTSIDE CORNER
CAPS/CONNECTORS)
INSIDE CORNER TRANSITION- TILED WALLS - TYPICAL PLAN VIEW
W
AL
L
WALL
OUTSIDE CORNER TRANSITION- TILED WALLS - TYPICAL
PORCELAIN
WALL TILE
PORCELAIN
WALL TILE
SCHLUTER;
STYLE: JOLLY
A100AT SATIN NICKEL
ANODIZED ALUMINUM
(W/ MATCHING
CAPS/CONNECTORS AS
REQUIRED)
PLAN VIEW
WALL
WALL
PORCELAIN
WALL TILE
W
AL
L
SCHLUTER; STYLE: RONDEC-DB; SATIN
NICKEL ANODIZED ALUMINUM
WALL TILE TO GYPSUM WALLBOARD - TYPICAL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L F
AC
ILI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
MS
C
OM
MA
ND
MI
D-
AT
LA
NT
IC
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
6/ 8/
:0
3:
P M
C :\R ev it
Lo ca l F ile s\ Q
-1
-I- R
_v irg in ia .p er ry
.rv t
IN601
SO
F
O W
LS
C
R
EE
K
BO
AT
M
AI
N
TE
N
AN
C
E
FA
C
IL
IT
Y
IN
TE
R
IO
R F
IN
IS
H T
R
AN
SI
TI
O N
S, S
C H
ED
U
LE
, A
N D
L
EG
EN
D
JW
12885665
AP AP
EAW/LEJ
1707671
VI
R
G
IN
A
BE
AC
H
, V
IR
G
IN
IA
N
AS
O
C
EA
N A, O W
LS
C
R
EE
K
DJA
JED
DSN
M
ID
LA
N
T D
C C
O R
E
IN
FINISH SCHEDULE NOTES
1 INTERIOR FINISHES ASSOCIATED WITH THE RESTROOM OPTION
2 INTERIOR FINISHES ASSOCIATED WITH THE OFFICE OPTION
3 BULLNOSE METAL TRIM ACCESSORY STRIP TO BE INSTALLED AT THE TOP OF THE RESINOUS EPOXY INTEGRAL FLOOR
BASE(EXB1)
4 WALL TILE TO BE INSTALLED TO 48”AFF WITH A BULLNOSE METAL TRIM ACCESSORY STRIP AT THE TOP.
5 ALL SHOWER PANS AND WALLS TO BE (SS2).
6 ALL CASEWORK TO HAVE (SS1) AS THE COUNTERTOP AND (PL1) FOR THE LAMINATE CABINETRY.
7 PROVIDE RUBBER BASE (RB1) AT ALL GYPSUM BOARD WALLS
8 PROVIDE STAINLESS STEEL WALL PANEL (SSWP1) BEHIND THE JANITOR MOP SINK.
9 PROVIDE CAULK JOINT AT WALL/FLOOR INTERSECTIONS WHERE RUBBER BASE DOES NOT OCCUR
1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND
SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF
CONSTRUCTION (OICC).
2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY
COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE
LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE
SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.
PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE
REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE
NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING
OFFICER.
3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.
IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN
TIME TO AVOID DELAYS.
4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND
CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF
THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN
THE CENTER OF A WALL.
5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION
JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY
BRUSH ARE NOT ACCEPTABLE.
6 TRANSITIONS MUST MEET ABA GUIDELINES.
7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER
DOOR.
8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE
METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS
THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A
COMPLETE INSTALLATION.
9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER
GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED
STONE WALLS.
10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED
ON EACH WALL.
GENERAL SHEET NOTES
FINISH SCHEDULE - FIRST FLOOR
ROOM
FLOOR BASE
CEILING WALL
NOTESNO. NAME FINISH NORTH FINISH
EAST
FINISH
SOUTH
FINISH WEST FINISH
101 HIGH BAY SC1 -- -- -- -- 7,8,9
102 ELECTRICAL SC1 --/RB1 P2 P1 P1 P1 P1 9
103 SECURITY
ROOM
SC1 --/RB1 P2 P1 P1 P1 P1 9
104 COMPRESSOR SC1 --/RB1 P2 P1 P1 P1 P1 9
105 MECHANICAL SC1 --/RB1 P2 P1 P1 P1 P1 9
106 RESTROOM EXY1 EXB1 P2 PWT1/P1 PWT1/P1 PWT1/P1 PWT1/P1 1,3,4,5
107 OFFICE EXY1 EXB1 ACT1 P1 P1 P1 P1 2,3,6
FINISH LEGEND
FINISH
TAG FINISH MANUFACTURER STYLE / COLOR NOTES
FLOOR FINISH
EXB1 INTEGRAL RESINOUS EPOXY BASE DUR-A-FLEX DURA-QUARTZ Q11/Q28-27 4"H
EXY1 RESINOUS EPOXY DUR-A-FLEX DURA-QUARTZ Q11/Q28-27
RB1 RUBBER WALL BASE ROPPE 148 STEEL GRAY 4"H
SC1 SEALED CONCRETE
WALL FINISH
GR1 EPOXY WALL GROUT CUSTOM BUILDING
PRODUCTS
#542 GRAYSTONE
P1 PAINT SHERWIN WILLIAMS SW7648 BIG CHILL EPOXY PAINT, EGGSHELL FINISH
PWT1 PORCELAIN WALL TILE ATLAS CONCORDE
USA
FRAY PEARL 12 X 24 MATTE FINISH
SS2 SOLID SURFACE WALL PANELS AVONITE 8016 WHITE 1/4" THICK
SSWP1 STAINLESS STEEL WALL PANEL INPRO STAINLESS STEEL SHEET WALL CLADDING 4' X 8' SHEET CUT TO FIT, INCLUDE
CORRESPONDING TRIMS
CEILING FINISH
ACT1 ACOUSTIC CEILING TILE ARMSTRONG CALLA 2822 WHITE 24 X 24 TEGULAR
P2 CEILING PAINT SHERWIN WILLIAMS SW7757 HIGH REFLECTIVE WHITE EPOXY PAINT, EGGSHELL FINISH
MISCELLANEOUS
CG1 CORNER GUARD INPRO CORP 3"W STAINLESS STEEL FLUSH MOUNT
CORNER GUARD
P3 DOOR AND TRIM PAINT SHERWIN WILLIAMS SW7074 PASSIVE SEMI-GLOSS FINISH
PL1 PLASTIC LAMINATE FORMICA 8829-38 GRAPHITE TWILL
S1 SIGNAGE BACKGROUND 2/90 SIGN SYSTEMS 756 SAPPHIRE BLUE
S2 SIGNAGE COPY 2/90 SIGN SYSTEMS 733 PEARL GREY
S3 SIGNAGE TRIM 2/90 SIGN SYSTEMS 104 BRUSHED NATURAL
SS1 SOLID SURFACE MEGANITE 704SA URBAN HABITAT
SCALE: 3" = 1'-0"B1 THRESHOLD DETAILS
SCALE: 12" = 1'-0"A1 WALL TRANSITIONS
SY
M
D E S
C R
IP
TI
O N
D
AT
E
FINISH BOARDS
FINISH BOARD 1- BASE BID
This is for presentation only. See sheet IN601 and the Specifications for full description & locations.
P‐1344
RB-1(RESILENT WALL BASE)
ROPPE, STEEL GRAY/148
P1 (EPOXY WALL PAINT) SHERWIN
WILIAMS, BIG CHILL /SW7648, EGGSHELL
FINISH
P2 (EPOXY CEILING PAINT) SHERWIN
WILIAMS, HIGH REFLECTIVE WHITE/ SW7757,
EGGSHELL FINISH
SSWP1(STAINLESS STEEL WALL PANEL) INPRO
FINISH BOARD 2 - OFFICE OPTION
This is for presentation only. See itemized Specifications for full description & locations.
P‐1344
EXY1 & EXB1 (RESINOUS EPOXY FLOORING &
INTEGRAL BASE) DUR-A-FLEX, DURA-QUARTZ
Q11/Q28-27
ACT1 (ACOUSTICAL CEILING TILE)
ARMSTRONG, CALLA/WHITE/2822, 24x24
TEGULAR
SS1 (SOLID SURFACE COUNTERTOP)
MEGANITE, URBAN HABITAT/ 704SA
PL1 (PLASTIC LAMINATE CASEWORK)
FORMICA, GRAPHITE TWILL/ 8829-38
FINISH BOARD 3 - OFFICE OPTION
P‐1344
P1 (EPOXY WALL PAINT) SHERWIN
WILIAMS, BIG CHILL /SW7648, EGGSHELL
FINISH
FINISH BOARD 4 - RESTROOMS
P‐1344
P2 (EPOXY CEILING PAINT) SHERWIN
WILIAMS, HIGH REFLECTIVE WHITE/ SW7757,
EGGSHELL FINISH
P1 (EPOXY WALL PAINT) SHERWIN
WILIAMS, BIG CHILL /SW7648, EGGSHELL
FINISH
EXY1 & EXB1 (RESINOUS EPOXY FLOORING &
INTEGRAL BASE) DUR-A-FLEX, DURA-QUARTZ
Q11/Q28-27
PWT1 (PORCELAIN WALL TILE) ATLAS
CONCORDE USA, FRAY PEARL, 12 X 24
MATTE FINISH
GR1 (WALL GROUT) COMMERCIAL
BUILDING PRODUCTS, #542
GRAYSTONE
| Q1344-1707671-SID PKG |
| Q1344 SID Package |
| Q1344U-1707671_09-INTERIORS |
| Q1344-1707671-A-R21 - AG601 - SIGNAGE SCHEDULES AND DETAILS |
| Q1344-1707671-I-R21 - IF101 - FURNITURE PLAN |
| Q1344-1707671-I-R21 - IF401 - FURNITURE PLAN, RESTROOM 106 OPTION |
| Q1344-1707671-I-R21 - IF402 - FURNITURE PLAN - OFFICE 107 OPTION |
| Q1344-1707671-I-R21 - IN101 - FLOOR FINISH PLAN |
| Q1344-1707671-I-R21 - IN401 - FLOOR FINISH PLAN - RESTROOM 106 OPTION |
| Q1344-1707671-I-R21 - IN402 - FLOOR FINISH PLAN - OFFICE 107 OPTION |
| Q1344-1707671-I-R21 - IN601 - INTERIOR FINISH TRANSITIONS, SCHEDULE, AND LEGEND |