AMENDMENT_0002_Q1344U-1707671_SID PACKAGE.pdf

PDF 1 MB Posted

Attached to
SOF OWLS CREEK BOAT MAINTENANCE FACILITY, NAVAL AIR STATION OCEANA, VIRGINIA BEACH, VIRGINIA
Solicitation number
N40085-23-R-2851
Issued by

About this file

This package includes structural interior design drawings and specifications for a boat maintenance facility project for the Department of the Navy. The drawings show proposed signage, furniture plans, floor finishes, and interior finish schedules. The signage drawings include schedules and details for room identification and directional signs. The furniture plans depict proposed furniture, fixtures and equipment for areas including a high bay, office option, and restroom option. Additional drawings illustrate proposed flooring materials for these areas as well as finish schedules designating proposed paints, wall and floor coverings. Specifications in the package provide further description and locations for proposed interior elements and finishes.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Q-1344

SOF BOAT MAINTENANCE AND

STORAGE FACILITY

NAS OCEANA, OWLS CREEK, VIRGINIA BEACH, VA

FINAL STRUCTURAL INTERIOR DESIGN PACKAGE

May 5, 2023

TABLE OF CONTENTS

1. STRUCTURAL INTERIOR DESIGN (SID) NARRATIVE

2. POINT OF CONTACT LIST

3. PLANS

4. FINISH BOARD

P-1344

STRUCTURAL INTERIOR

DESIGN (SID)

NARRATIVE

P‐1344

The SID (Structural Interior Design) package and the FF&E (Furniture, Fixtures, & Equipment) package will be fully coordinated with one another, as well as with the building support systems, in order to create a cohesive final design.

Barrier-free design features will be incorporated to comply with the most stringent requirements by the Architectural Barriers Act (ABA) Standards.

Sustainability focused design features will be included to comply with UFC 1-200-02.

Durable, low maintenance interior finishes will be used throughout the facility for ease of maintenance. The floor surface throughout the High Bay and utility rooms (Electrical, Compressor, and Mechanical) will receive sealed concrete. The Office and Restroom Options will received a 5-part resinous epoxy flooring system.

Wall finishes for the high Bay will be the standard PEMB interior wall finishes. All interior spaces (Electrical, Compressor, Mechanical, and Office Option) will receive painted impact resistant gypsum wall board (GWB). Restroom option will receive a porcelain wall tile wainscot with moisture resistant gypsum wall board above and epoxy paint. All interior exposed surfaces including metal frames, grilles, registers, diffusers, access panels, and panel boxes will be painted to match the adjacent wall or ceiling surface, excepting factory finished items.

Ceilings in the Office Option will be acoustical ceiling tile (ACT). GWB ceilings finished with epoxy paint will occur at the Electrical, Compressor, Mechanical and Restroom Option. Exposed ceiling in the High Bay.

Casework in the office will receive high pressure plastic laminate cabinetry and solid surface counters.

Interior building signage will align with the Signage UFC and ABA Guidelines.

POINTS OF CONTACT

POINTS OF CONTACT LIST

ACTIVITY REPRESENTATIVE

Nelvin J. Omandan General Engineer

NSWDG

757-862-9039 nelvin.j.omandan.civ@socom.mil

PROJECT MANAGER

Beth White Phone: 214-868-6409 Elizabeth.a.white136.civ@us.navy.mil

DESIGN MANAGER

Lawrence E. Johns Phone: 757-341-2054 lawrence.e.johns4.civ@us.navy.mil

INTERIOR DESIGNER

Ann Perry Phone: 757-341-0141 virginia.b.perry.civ@us.navy.mil

PLANS

CL

EQ EQ

CL

1 2 3

NOTE: MOUNT ON LATCH SIDE OF DOOR OR

ADJACENT WALL.

NOTE: MOUNT ON CENTER OF DOOR. NOTE: MOUNTING HEIGHT FOR

LOCATIONS WITHOUT DOORS

9"

TEXT

TEXT

MINIMUM HEIGHT - 4'-0" FROM

BASELINE OF LOWEST TACTILE

CHARACTER

MAXIMUM HEIGHT - 5'-0" FROM

BASELINE OF HIGHEST TACTILE

CHARACTER

4'- 0"

5'- 0"

TEXT

TEXT

SIGNS WITH TACTILE LETTERS ARE PERMITTED ON

THE PUSH SIDE OF DOORS WITH CLOSERS AND

WITHOUT HOLD-OPEN DEVICES WHEN NO WALL

SPACES ARE AVAILABLE.

ELECTRICAL

ROOM

NAME

REMOVABLE END CAPS

3" 2"

9"

TEXT: 1-1/2" TACTILE ROOM NUMBER WITH

GRADE 2 BRAILLE HELVETICA NEUE 55

ROMAN

TEXT: 3/4" TACTILE ROOM NAME,

HELVETICA NEUE 55 ROMAN

9"

3" 6"

9"

TEXT: 1-1/2" TACTILE ROOM NUMBER WITH

GRADE 2 BRAILLE HELVETICA NEUE 55

ROMAN

TEXT: 3/4" PRINTED PAPER ROOM NAME,

HELVETICA NEUE 55 ROMAN

SIGN TYPE A

SIGN TYPE C

NO SMOKING

9"

SIGN TYPE K

TEXT: 1-1/2" TACTILE ROOM NUMBER WITH

GRADE 2 BRAILLE HELVETICA NEUE 55

ROMAN3"

9"

SIGN TYPE BREMOVABLE END CAPS

REMOVABLE END CAPS

TEXT: 5/8" TACTILE MESSAGE

W/ GRADE 2 BRAILLE

HELVETICA NEUE 55 ROMAN

3"

9"

REMOVABLE END CAPS

SIGN TYPE Q

EXIT ONLY

UNISEX

101 TEXT: 1-1/2" TACTILE MESSAGE WITH GRADE 2

BRAILLE HELVETICA NEUE 55 ROMAN

TEXT: RAISED PICTOGRAM

TEXT: 3/4" TACTILE ROOM NAME WITH GRADE

2 BRAILLE HELVETICA NEUE 55 ROMAN3"

8" 3"

1'- 2"

11"

SIGN TYPE R

REMOVABLE END CAPS

SIGN TYPE T

8 1/2"

6"

FIRE

EXTINGUISHER

1" 1"

FIRE

EXTINGUISHER

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:2

0:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-A -R

_v irg in ia .p er ry

.rv t

AG601

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

SI

G

N

AG

E

SC

H

ED

U

LE

S

AN

D D

ET

AI

LS

CM

12885658

AP AP

EAW/LEJ

1707671

VI

R

G

IN

IA

B

EA

C

H , V

IR

G

IN

IA

N

AS

O C

EA

N

A, O

W

LS

C R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

AG

SIGNAGE SCHEDULE

ROOM LOCATION

SIGN TYPE SIGN TEXT QTY

DOORWAY

LOCATION NOTESNO. NAME

101 HIGH BAY TYPE Q 2 3

101 HIGH BAY TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE

EXTINGUISHER

102 ELECTRICAL TYPE A 1 2 EXTERIOR

102 ELECTRICAL TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE

EXTINGUISHER

103 SECURITY

ROOM

TYPE A 1 2

104 COMPRESSO

R

TYPE A 1 2

104 COMPRESSO

R

TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE

EXTINGUISHER

105 MECHANICAL TYPE A 1 2 EXTERIOR

105 MECHANICAL TYPE T 1 INSTALL 6'-6" AFF ABOVE FIRE

EXTINGUISHER

106 RESTROOM TYPE R 1 2

107 OFFICE TYPE C 1 2

GENERAL SHEET NOTES

SCALE: 3/4" = 1'-0"A1 SIGNAGE DOORWAY LOCATIONS

SCALE: 3" = 1'-0"C1 SIGNAGE TYPICAL DETAILS

1 ALL SIGN TYPES, TEXT, AND ROOM NUMBERS MUST BE VERIFIED WITH END

USER AND APPROVED BY CONSTRUCTION MANAGER PRIOR TO FABRICATION

2 THE LOCATION OF SIGNS AS NOTED ON THIS SHEET IS FOR GENERAL

REFERENCE ONLY AND IN SOME CASES IS NOT REPRESENTATIVE OF THE

EXACT FINAL LOCATION. LOCATIONS OF SIGNS SHALL BE DETERMINED IN

COORDINATION WITH THE PROJECT ARCHITECT AND THE CONSTRUCTION

MANAGER AT THE SITE. SIGN FABRICATOR MUST ARRANGE FOR MEETING AT

THE SITE TO COORDINATE AND CONFIRM FINAL SIGNAGE LOCATIONS

3 SIGNAGE MUST BE FABRICATED AND INSTALLED TO MEET ABA

REQUIREMENTS WITH REGARD TO BRAILLE, RAISED CHARACTERS, FINISHES

(CONTRAST), SIZE AND MOUNTING HEIGHT

5 MOUNTING OF SIGNAGE MUST BE BY MECHANICAL FASTENERS

6 UNLESS OTHERWISE NOTED, SIGNS ARE FOR INTERIOR USE

7 SIGNAGE FINISHES ARE AS LISTED ON SHEET IN601

SY

M

D E S

C R

IP

TI

O N

D

AT

E

AP

PR

HIGH BAY

MECHANICAL

COMPRESSOR

SECURITY ROOM

ELECTRICAL

M06

M06

S01

S02 A01

OFFICE

OPTION

RESTROOM

OPTION

IF402

B2

IF401

B2

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IF101

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FU

R

N

IT

U R

E

PL

AN

JW

12885659

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IF

SCALE: 1/8" = 1'-0"

FURNITURE PLAN

PLAN

NORTH

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED

FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT

PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS

WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO

THE CONSTRUCTION CONTRACT.

2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR

MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,

STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,

AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND

EQUIPMENT.

FF&E SCHEDULE

MARK NAME

A01 CLOCK WALL-MOUNT 12" DIAMETER

C01 UPHOLSTERED TASK CHAIR WITH ARMS

D01 30X54 SIT/STAND DESK

M01 REFRIGERATOR, NO ICE MAKER

M02 COUNTERTOP MICROWAVE

M03 COFFEE BREWER -1 BURNER, NON-PLUMBED

M04 TRASH CAN 14"L x 10"D x 14"H

M05 SHOWER CURTAIN

M06 55 GALLON TRASH CAN WITH LID

S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H

S02 MRV STORAGE RACK

T01 42" DIA ROUND TABLE

1/8" = 1'-0" 4' 8' 16'0'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

M05M05

RESTROOM

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IF401

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FU

R

N

IT

U R

E

PL

AN

, R

ES

TR

O O

M

O

PT

IO

N

JW

12885660

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IF

SCALE: 3/8" = 1'-0" (IF101)B2 FURNITURE PLAN - RESTROOM OPTION

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

FF&E SCHEDULE

MARK NAME

A01 CLOCK WALL-MOUNT 12" DIAMETER

C01 UPHOLSTERED TASK CHAIR WITH ARMS

D01 30X54 SIT/STAND DESK

M01 REFRIGERATOR, NO ICE MAKER

M02 COUNTERTOP MICROWAVE

M03 COFFEE BREWER -1 BURNER, NON-PLUMBED

M04 TRASH CAN 14"L x 10"D x 14"H

M05 SHOWER CURTAIN

M06 55 GALLON TRASH CAN WITH LID

S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H

S02 MRV STORAGE RACK

T01 42" DIA ROUND TABLE

1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED

FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT

PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS

WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO

THE CONSTRUCTION CONTRACT.

2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR

MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,

STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,

AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND

EQUIPMENT.

3/8" = 1'-0" 0' 2' 4' 6'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

A01

D01C01

M04

C01 D01

M04

T01C01

C01

M01

M03 M02

OFFICE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IF402

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FU

R

N

IT

U R

E

PL

AN

O

FF

IC

E

O

PT

IO

N

JW

12885661

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IF

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

SCALE: 3/8" = 1'-0" (IF101)B2 FURNITURE PLAN - OFFICE OPTION

FF&E SCHEDULE

MARK NAME

A01 CLOCK WALL-MOUNT 12" DIAMETER

C01 UPHOLSTERED TASK CHAIR WITH ARMS

D01 30X54 SIT/STAND DESK

M01 REFRIGERATOR, NO ICE MAKER

M02 COUNTERTOP MICROWAVE

M03 COFFEE BREWER -1 BURNER, NON-PLUMBED

M04 TRASH CAN 14"L x 10"D x 14"H

M05 SHOWER CURTAIN

M06 55 GALLON TRASH CAN WITH LID

S01 FLAMMABLE STORAGE CABINET 48"W x 24"D X 72"H

S02 MRV STORAGE RACK

T01 42" DIA ROUND TABLE

1 ALL FURNITURE, FIXURES, AND EQUIPMENT (FF&E) INDICATED IS PROVIDED

FOR COORDINATION PURPOSES ONLY. PROCUREMENT OF NEW FF&E IS NOT

PART OF THE BASE BID CONSTRUCTION CONTRACT. CONSTRUCTION FUNDS

WILL NOT BE USED. FF&E WILL BE FUNDED SEPARATELY AS AN OPTION TO

THE CONSTRUCTION CONTRACT.

2 SEE SPECIFICATION SECTION 01 30 01.00 22 AND PRICE SCHEDULE FOR

MORE INFORMATION ON DESIGN, INVENTORY OF EXISTING FURNITURE,

STORAGE OF EXISTING FURNITURE, PROCUREMENT OF NEW FURNITURE,

AND INSTALLATION OF BOTH NEW AND EXISTING FURNITURE, FIXTURES, AND

EQUIPMENT.

3/8" = 1'-0" 0' 2' 4' 6'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

OFFICE

OPTION

RESTROOM

OPTION

IN402

B2

IN401

B2

FLOOR FINISH LEGEND

SEALED CONCRETE

RESINOUS EPOXY

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IN101

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FL

O

O R

F

IN

IS

H

P

LA

N

JW

12885662

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IN

SCALE: 1/8" = 1'-0"

FLOOR FINISH PLAN

PLAN

NORTH

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND

SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF

CONSTRUCTION (OICC).

2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY

COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE

LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE

SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE

REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE

NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING

OFFICER.

3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.

IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN

TIME TO AVOID DELAYS.

4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND

CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF

THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN

THE CENTER OF A WALL.

5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION

JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY

BRUSH ARE NOT ACCEPTABLE.

6 TRANSITIONS MUST MEET ABA GUIDELINES.

7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER

DOOR.

8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS

THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A

COMPLETE INSTALLATION.

9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER

GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED

STONE WALLS.

10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED

ON EACH WALL.

1/8" = 1'-0" 4' 8' 16'0'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

FLOOR FINISH LEGEND

SEALED CONCRETE

RESINOUS EPOXY

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IN401

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FL

O

O R

F

IN

IS

H

P

LA

N

R

ES

TR

O

O M

O

PT

IO

N

JW

12885663

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IN

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND

SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF

CONSTRUCTION (OICC).

2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY

COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE

LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE

SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE

REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE

NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING

OFFICER.

3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.

IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN

TIME TO AVOID DELAYS.

4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND

CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF

THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN

THE CENTER OF A WALL.

5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION

JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY

BRUSH ARE NOT ACCEPTABLE.

6 TRANSITIONS MUST MEET ABA GUIDELINES.

7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER

DOOR.

8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS

THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A

COMPLETE INSTALLATION.

9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER

GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED

STONE WALLS.

10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED

ON EACH WALL.

SCALE: 3/8" = 1'-0" (IN101)B2 FLOOR FINISH PLAN - RESTROOM OPTION

3/8" = 1'-0" 0' 2' 4' 6'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

FLOOR FINISH LEGEND

SEALED CONCRETE

RESINOUS EPOXY

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

2:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IN402

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

FL

O

O R

F

IN

IS

H

P

LA

N

O

FF

IC

E

O

PT

IO

N

JW

12885664

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IN

GENERAL SHEET NOTES

GRAPHIC SCALE(S)

1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND

SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF

CONSTRUCTION (OICC).

2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY

COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE

LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE

SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE

REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE

NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING

OFFICER.

3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.

IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN

TIME TO AVOID DELAYS.

4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND

CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF

THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN

THE CENTER OF A WALL.

5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION

JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY

BRUSH ARE NOT ACCEPTABLE.

6 TRANSITIONS MUST MEET ABA GUIDELINES.

7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER

DOOR.

8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS

THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A

COMPLETE INSTALLATION.

9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER

GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED

STONE WALLS.

10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED

ON EACH WALL.

SCALE: 3/8" = 1'-0" (IN101)B2 FLOOR FINISH PLAN - OFFICE OPTION

3/8" = 1'-0" 0' 2' 4' 6'

SY

M

D E S

C R

IP

TI

O N

D

AT

E

TOP OF CONCRETE

FLOOR SLAB

T1

EXTERIOR DOOR

SEALED

CONCRETE

ALUMINUM THRESHOLD

EPOXY

RESINOUS EPOXY BASE TO RESINOUS EPOXY FLOORING - TYPICAL

W

AL

L

SCHLUTER; STYLE: RONDEC-DB; SATIN

NICKEL ANODIZED ALUMINUM

RESINOUS EPOXY FLOORING/BASE TO PORCELAIN WALL TILE - TYPICAL

RESINOUS EPOXY BASE

W

AL

L

FLOOR RESINOUS EPOXY FLOORING

INTEGRAL COVE

METAL TRANSITION STRIP

PORCELAIN WALL TILE

RESINOUS EPOXY BASE

RESINOUS EPOXY FLOORING

INTEGRAL COVE

FLOOR

PORCELAIN

WALL TILE

PORCELAIN

WALL TILE

SCHLUTER; STYLE: DILEX

AHK; SATIN NICKEL ANODIZED ALUMINUM

(W/ MATCHING INSIDE/OUTSIDE CORNER

CAPS/CONNECTORS)

INSIDE CORNER TRANSITION- TILED WALLS - TYPICAL PLAN VIEW

W

AL

L

WALL

OUTSIDE CORNER TRANSITION- TILED WALLS - TYPICAL

PORCELAIN

WALL TILE

PORCELAIN

WALL TILE

SCHLUTER;

STYLE: JOLLY

A100AT SATIN NICKEL

ANODIZED ALUMINUM

(W/ MATCHING

CAPS/CONNECTORS AS

REQUIRED)

PLAN VIEW

WALL

WALL

PORCELAIN

WALL TILE

W

AL

L

SCHLUTER; STYLE: RONDEC-DB; SATIN

NICKEL ANODIZED ALUMINUM

WALL TILE TO GYPSUM WALLBOARD - TYPICAL

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D

EP

AR

TM

EN

T

O F

TH

E

N

AV

Y N

AV

AL

F

AC

IL

IT

IE

S

EN

G

IN

EE

R

IN

G S

YS

TE

M S

C O

M M

AN

D

DRAWFORM REVISION: 25 AUGUST 2020

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

NA

VA

L F

AC

ILI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

MS

C

OM

MA

ND

MI

D-

AT

LA

NT

IC

N

AV

AL

S

TA

TI

O N

N

O R

FO

LK

, V A

AS NOTED

6/ 8/

:0

3:

P M

C :\R ev it

Lo ca l F ile s\ Q

-1

-I- R

_v irg in ia .p er ry

.rv t

IN601

SO

F

O W

LS

C

R

EE

K

BO

AT

M

AI

N

TE

N

AN

C

E

FA

C

IL

IT

Y

IN

TE

R

IO

R F

IN

IS

H T

R

AN

SI

TI

O N

S, S

C H

ED

U

LE

, A

N D

L

EG

EN

D

JW

12885665

AP AP

EAW/LEJ

1707671

VI

R

G

IN

A

BE

AC

H

, V

IR

G

IN

IA

N

AS

O

C

EA

N A, O W

LS

C

R

EE

K

DJA

JED

DSN

M

ID

LA

N

T D

C C

O R

E

IN

FINISH SCHEDULE NOTES

1 INTERIOR FINISHES ASSOCIATED WITH THE RESTROOM OPTION

2 INTERIOR FINISHES ASSOCIATED WITH THE OFFICE OPTION

3 BULLNOSE METAL TRIM ACCESSORY STRIP TO BE INSTALLED AT THE TOP OF THE RESINOUS EPOXY INTEGRAL FLOOR

BASE(EXB1)

4 WALL TILE TO BE INSTALLED TO 48”AFF WITH A BULLNOSE METAL TRIM ACCESSORY STRIP AT THE TOP.

5 ALL SHOWER PANS AND WALLS TO BE (SS2).

6 ALL CASEWORK TO HAVE (SS1) AS THE COUNTERTOP AND (PL1) FOR THE LAMINATE CABINETRY.

7 PROVIDE RUBBER BASE (RB1) AT ALL GYPSUM BOARD WALLS

8 PROVIDE STAINLESS STEEL WALL PANEL (SSWP1) BEHIND THE JANITOR MOP SINK.

9 PROVIDE CAULK JOINT AT WALL/FLOOR INTERSECTIONS WHERE RUBBER BASE DOES NOT OCCUR

1 FOR QUESTIONS REGARDING INTERIOR DESIGN DRAWINGS AND

SPECIFICATIONS CONTACT: NAVFAC OFFICE IN CHARGE OF

CONSTRUCTION (OICC).

2 FINISHES INDICATED ARE THE APPROVED BASIS OF DESIGN TO CONVEY

COLOR, PATTERN, TEXTURE AND SALIENT CHARACTERISTICS ONLY. THE

LISTING OF MANUFACTURER INFORMATION IS NOT INTENDED TO LIMIT THE

SELECTION OF PRODUCTS PROVIDED BY OTHER MANUFACTURERS.

PRODUCTS MEETING THESE CRITERIA WILL BE CONSIDERED AND MUST BE

REVIEWED BY THE INTERIOR DESIGNER OF RECORD (IDOR) AND THE

NAVFAC INTERIOR DESIGNER AND APPROVED BY THE CONTRACTING

OFFICER.

3 FINISH ITEMS MUST NOT BE SUBSTITUTED DUE TO ORDERING LEAD TIMES.

IT IS THE CONTRACTOR’S RESPONSIBILITY TO ORDER ALL MATERIALS IN

TIME TO AVOID DELAYS.

4 COORDINATE THERMOSTAT LOCATION WITH MECHANICAL DRAWINGS AND

CONSTRUCTION MANAGER. INSTALL THERMOSTATS NEAR A CORNER OF

THE ROOM OR BY LIGHT SWITCHES. DO NOT INSTALL THERMOSTATS IN

THE CENTER OF A WALL.

5 SPRAY PAINT ELECTRICAL PANELS, ACCESS PANELS, AND EXPANSION

JOINTS TO MATCH THE ADJACENT WALL COLOR. PANELS PAINTED BY

BRUSH ARE NOT ACCEPTABLE.

6 TRANSITIONS MUST MEET ABA GUIDELINES.

7 TRANSITIONS OCCURRING UNDER DOORS MUST BE CENTERED UNDER

DOOR.

8 ROOMS IDENTIFIED TO RECEIVE TILE ON WALLS, FLOOR MUST INCLUDE

METAL TRANSITIONS ON ALL OUTSIDE, AND INSIDE CORNERS AS WELL AS

THE INTERSECTION BETWEEN THE FLOOR AND WALL TILE FOR A

COMPLETE INSTALLATION.

9 PROVIDE CORNER GUARDS (CG) ON ALL OUTSIDE CORNERS. CORNER

GUARDS SHOULD NOT BE USED ON CMU WALLS OR MANUFACTURED

STONE WALLS.

10 ALIGN ALL PORCELAIN WALL AND FLOOR TILE. TILE MUST BE CENTERED

ON EACH WALL.

GENERAL SHEET NOTES

FINISH SCHEDULE - FIRST FLOOR

ROOM

FLOOR BASE

CEILING WALL

NOTESNO. NAME FINISH NORTH FINISH

EAST

FINISH

SOUTH

FINISH WEST FINISH

101 HIGH BAY SC1 -- -- -- -- 7,8,9

102 ELECTRICAL SC1 --/RB1 P2 P1 P1 P1 P1 9

103 SECURITY

ROOM

SC1 --/RB1 P2 P1 P1 P1 P1 9

104 COMPRESSOR SC1 --/RB1 P2 P1 P1 P1 P1 9

105 MECHANICAL SC1 --/RB1 P2 P1 P1 P1 P1 9

106 RESTROOM EXY1 EXB1 P2 PWT1/P1 PWT1/P1 PWT1/P1 PWT1/P1 1,3,4,5

107 OFFICE EXY1 EXB1 ACT1 P1 P1 P1 P1 2,3,6

FINISH LEGEND

FINISH

TAG FINISH MANUFACTURER STYLE / COLOR NOTES

FLOOR FINISH

EXB1 INTEGRAL RESINOUS EPOXY BASE DUR-A-FLEX DURA-QUARTZ Q11/Q28-27 4"H

EXY1 RESINOUS EPOXY DUR-A-FLEX DURA-QUARTZ Q11/Q28-27

RB1 RUBBER WALL BASE ROPPE 148 STEEL GRAY 4"H

SC1 SEALED CONCRETE

WALL FINISH

GR1 EPOXY WALL GROUT CUSTOM BUILDING

PRODUCTS

#542 GRAYSTONE

P1 PAINT SHERWIN WILLIAMS SW7648 BIG CHILL EPOXY PAINT, EGGSHELL FINISH

PWT1 PORCELAIN WALL TILE ATLAS CONCORDE

USA

FRAY PEARL 12 X 24 MATTE FINISH

SS2 SOLID SURFACE WALL PANELS AVONITE 8016 WHITE 1/4" THICK

SSWP1 STAINLESS STEEL WALL PANEL INPRO STAINLESS STEEL SHEET WALL CLADDING 4' X 8' SHEET CUT TO FIT, INCLUDE

CORRESPONDING TRIMS

CEILING FINISH

ACT1 ACOUSTIC CEILING TILE ARMSTRONG CALLA 2822 WHITE 24 X 24 TEGULAR

P2 CEILING PAINT SHERWIN WILLIAMS SW7757 HIGH REFLECTIVE WHITE EPOXY PAINT, EGGSHELL FINISH

MISCELLANEOUS

CG1 CORNER GUARD INPRO CORP 3"W STAINLESS STEEL FLUSH MOUNT

CORNER GUARD

P3 DOOR AND TRIM PAINT SHERWIN WILLIAMS SW7074 PASSIVE SEMI-GLOSS FINISH

PL1 PLASTIC LAMINATE FORMICA 8829-38 GRAPHITE TWILL

S1 SIGNAGE BACKGROUND 2/90 SIGN SYSTEMS 756 SAPPHIRE BLUE

S2 SIGNAGE COPY 2/90 SIGN SYSTEMS 733 PEARL GREY

S3 SIGNAGE TRIM 2/90 SIGN SYSTEMS 104 BRUSHED NATURAL

SS1 SOLID SURFACE MEGANITE 704SA URBAN HABITAT

SCALE: 3" = 1'-0"B1 THRESHOLD DETAILS

SCALE: 12" = 1'-0"A1 WALL TRANSITIONS

SY

M

D E S

C R

IP

TI

O N

D

AT

E

FINISH BOARDS

FINISH BOARD 1- BASE BID

This is for presentation only. See sheet IN601 and the Specifications for full description & locations.

P‐1344

RB-1(RESILENT WALL BASE)

ROPPE, STEEL GRAY/148

P1 (EPOXY WALL PAINT) SHERWIN

WILIAMS, BIG CHILL /SW7648, EGGSHELL

FINISH

P2 (EPOXY CEILING PAINT) SHERWIN

WILIAMS, HIGH REFLECTIVE WHITE/ SW7757,

EGGSHELL FINISH

SSWP1(STAINLESS STEEL WALL PANEL) INPRO

FINISH BOARD 2 - OFFICE OPTION

This is for presentation only. See itemized Specifications for full description & locations.

P‐1344

EXY1 & EXB1 (RESINOUS EPOXY FLOORING &

INTEGRAL BASE) DUR-A-FLEX, DURA-QUARTZ

Q11/Q28-27

ACT1 (ACOUSTICAL CEILING TILE)

ARMSTRONG, CALLA/WHITE/2822, 24x24

TEGULAR

SS1 (SOLID SURFACE COUNTERTOP)

MEGANITE, URBAN HABITAT/ 704SA

PL1 (PLASTIC LAMINATE CASEWORK)

FORMICA, GRAPHITE TWILL/ 8829-38

FINISH BOARD 3 - OFFICE OPTION

P‐1344

P1 (EPOXY WALL PAINT) SHERWIN

WILIAMS, BIG CHILL /SW7648, EGGSHELL

FINISH

FINISH BOARD 4 - RESTROOMS

P‐1344

P2 (EPOXY CEILING PAINT) SHERWIN

WILIAMS, HIGH REFLECTIVE WHITE/ SW7757,

EGGSHELL FINISH

P1 (EPOXY WALL PAINT) SHERWIN

WILIAMS, BIG CHILL /SW7648, EGGSHELL

FINISH

EXY1 & EXB1 (RESINOUS EPOXY FLOORING &

INTEGRAL BASE) DUR-A-FLEX, DURA-QUARTZ

Q11/Q28-27

PWT1 (PORCELAIN WALL TILE) ATLAS

CONCORDE USA, FRAY PEARL, 12 X 24

MATTE FINISH

GR1 (WALL GROUT) COMMERCIAL

BUILDING PRODUCTS, #542

GRAYSTONE

Q1344-1707671-SID PKG
Q1344 SID Package
Q1344U-1707671_09-INTERIORS
Q1344-1707671-A-R21 - AG601 - SIGNAGE SCHEDULES AND DETAILS
Q1344-1707671-I-R21 - IF101 - FURNITURE PLAN
Q1344-1707671-I-R21 - IF401 - FURNITURE PLAN, RESTROOM 106 OPTION
Q1344-1707671-I-R21 - IF402 - FURNITURE PLAN - OFFICE 107 OPTION
Q1344-1707671-I-R21 - IN101 - FLOOR FINISH PLAN
Q1344-1707671-I-R21 - IN401 - FLOOR FINISH PLAN - RESTROOM 106 OPTION
Q1344-1707671-I-R21 - IN402 - FLOOR FINISH PLAN - OFFICE 107 OPTION
Q1344-1707671-I-R21 - IN601 - INTERIOR FINISH TRANSITIONS, SCHEDULE, AND LEGEND

File details come from the government source that posted it. Updated .