21-0025 Lead Survey - 1-2.pdf

PDF 11 MB Posted

Attached to
Infrastructure Reset Demo Package F Federal contract opportunity
Solicitation number
N4008522B2510
Issued by
Department of the Navy Naval Facilities Engineering Command

About this file

This document provides details on a federal solicitation for demolition services. The solicitation number is N4008522B2510 and is for the Infrastructure Reset Demo Package F project through the Department of the Navy Naval Facilities Engineering Command. The project scope involves demolishing various buildings according to provided plans and specifications. No other details are included regarding response dates, pricing terms, set asides, incumbent contractors, or other salient information needed to fully understand the procurement requirements or evaluation criteria.

View the file

Other files for this federal contract opportunity

Other files attached to Infrastructure Reset Demo Package F, newest first.
File Type Posted
N4008522B2510 Amendment 0005.pdf PDF
N4008522B2510 Amendment 0004.pdf PDF
N4008522B2510 Amendment 0003.pdf PDF
N4008522B2510 Amendment 0002.pdf PDF
Amendment 0001.pdf PDF
21-0025 Abestos Survey - 2-2.pdf PDF
21-0025 Asbestos Survey - 1-2.pdf PDF
N4008521B0025 Specs.pdf PDF
N4008521B0025 Drawings.pdf PDF
21-0025 Lead Survey - 2-2.pdf PDF
N4008522B2510 IR Demo Package F Solicitation.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Lead Paint Survey IR Demo Package F

Marine Corps Base Camp Lejeune Project # 21-0025

Report Prepared By:

Christopher B. Walker

The Walker Group Architecture, Inc October 20th, 2021

WGA Project No. – 2107.DEMF

Project Information

The Walker Group Architecture, Inc. was contracted by Camp Lejeune to conduct an lead sampling survey for Buildings/Structures: 14, 33, 41, 207, 315, 319, 334, 344, 344, 400, 431, 1042, 1819, AS3906, AS4114, BB269, FC260, H35, M203, M441, RR206, RR207, S58N, SAS888, SAS2849, SAS3601, SBA149, SBB154, SFC254, SG401, SG555, STC953, TC1064, TC1065, TC1066, TC1067, TC1068, TC1069. Structures S58N, SBB154, SAS888, SBA149, STC953 where inspected with no suspect materials found.

The specified buildings or structures are slated for demolition on board Marine Corps Base Camp Lejeune. The survey was conducted to determine if building components were coated with lead-based paint.

Scope of Services

A. The survey was performed on 10/14/21, 10/15/21, 10/27/21, 11/04/21, 11/08/21 by Christopher B. Walker (NC Accredited Lead Inspector #110239 expires June 30th, 2022. Samples were collected from areas defined by the scope of work.

Findings

A. The Walker Group Architecture collected paint chip samples from each surface visibly coated with a different color of paint and delivered them to EMSL Analytical, Inc. (AIHA ELLAP lab code no. 102564) for analysis for lead content by Flame AAS (SW 846 3050B*/7420) in accordance with EPA 3050B/Modified/7000B. OSHA 29 CFR

1926.62 defines any detectable level of lead in paint a concern when renovations/demolitions will impact lead coated surfaces.

B. The detection limit is determined by weight of the sample, which is typically 0.01%.

See attached Lab Results for additional information.

Building 14

Building Description and Findings (Inspected 10-14-21)

Building 14 is a decommissioned office building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of wood framing and asphalt shingles.

Laboratory Results

Suspect Material Sampled Location Condition Concentration

% by Weight White wood Exterior porch Fair 0.13% Tan wood Interior trim Intact <0.0080% Tan metal door frames Interior Doors Intact <0.0080% White concrete Exterior foundation wall/sills Fair 0.018% Black concrete Front steps/porch Fair 0.010% Cream gypsum board Interior walls Intact <0.0080%

Based on the sample analysis, the following coatings should be considered Lead Based Paint:

White exterior wood White exterior concrete Black exterior concrete

Building 33

Building 33 is an operational office building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum/plaster walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of wood framing and asphalt shingles.

% by Weight White wood trim Interior trim Intact 0.62% Cream plaster Interior walls Intact 0.16% Cream gypsum board Interior walls Intact <0.0080% White wood stair rail Interior stair Intact 0.57% Black wood stair stringer Interior stair Intact 1.3% White exterior wood Exterior trim/fascia Fair <0.0080% Gray steel columns Exterior columns Fair 22% Gray steel stair Exterior stair Intact 0.019% White concrete sills Exterior sills Intact 0.27%

White wood trim Cream plaster White wood stair rail Black wood stair stringer Gray steel columns Gray steel stair White concrete sills

Building 41

Building Description and Findings (Inspected 11-08-21)

Building is an occupied office building. The existing exterior is brick veneer with wood stud wall and roof structure. The roof is asphalt shingles over wood decking. Interior walls are wood stud and gypsum board/plaster.

% by Weight White wood trim Exterior wood trim intact 9.0% White concrete Exterior base intact 0.12% White plaster ceiling Interior ceilings intact <0.014% Cream wood trim Interior trim intact <0.0080% Cream gypsum board Interior walls intact <0.0080% Cream plaster walls Interior walls intact 0.027% White wood doors Interior doors intact 0.0091% Cream CMU Interior walls intact <0.0080%

Based on the sample analysis, the following coatings should be considered to contain Lead Based Paint:

White wood trim White concrete Cream plaster walls White wood doors

Building 207

Building Description and Findings (Inspected 05-18-20)

Building 207 is an operational storage building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of steel framing and asphalt shingles.

% by Weight White interior brick Interior brick intact 0.056% Gray interior metal doors Metal doors intact <0.013% Gray exterior metal door frame Door frames intact 14% White exterior concrete Exterior concrete intact 0.041% Yellow exterior concrete safety paint Exterior step at door intact 0.050%

White interior brick Gray exterior metal door frame

Yellow exterior concrete safety paint

Building 315

Building 315 is an operational office building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of wood framing and asphalt shingles.

% by Weight White concrete Exterior foundation wall/sills fair 0.013% Blue plaster Interior walls Intact <0.0080% White plaster Interior walls Intact 0.22% White metal door frame Interior metal door frames Intact <0.0080% White wood Exterior fascia poor 13% Gray concrete Exterior porch Intact 0.051% White stucco Exterior porch Intact <0.0080% Black wood base Interior base Intact 0.28%

White concrete exterior foundation White plaster walls White exterior wood fascia Gray concrete porch Black interior wood base

Building 319

Building 319 is an occupied classroom building. The existing exterior is brick and cmu cavity wall and the roof structure is steel framing with wood decking/ asphalt shingles.

% by Weight Red steel door Exterior doors intact 1.9% White concrete Exterior wall base fair 0.37% White wood Exterior trim fair 5.8% Gray mechanical vent Roof vent intact 6.1% Cream brick Interior walls fair 0.028% Brown cmu Interior walls intact 0.092%

Red steel door White concrete base White wood trim Gray mechanical vent Cream brick Brown CMU

Building 334

Building Description and Findings (Inspected 10-15-21)

Building 334 is an operational fitness and office building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of wood framing and asphalt shingles.

Laboratory Results

Suspect Material Sampled Location Condition Concentration

% by Weight White concrete Exterior sills fair 0.17% Gray metal roof vent Roof vent poor 3.7% White wood Exterior siding fair 9.0% Red steel door Exterior doors fair 0.062% White gypsum board Interior walls Intact <0.0080% White interior wood Interior trim Intact <0.0080% Gray metal door frame Interior doors Intact <0.047% Red brick Interior walls in gym area Intact <0.011% Black brick Interior walls in gym area Intact 0.77% Red concrete beam/structure Structure in gym area Intact 0.17% Gray concrete floor Floor in gym area fair <0.0080%

White exterior concrete Gray metal roof vent White wood siding Red steel door Black interior brick Red concrete beam/structure

Building 344

Building Description and Findings (Inspected 05-02-19)

Building 344 is an operational office building. The existing exterior is brick and stud cavity walls with interior wood stud and gypsum walls. The building has a drop-down acoustical tile ceiling throughout. The roof consists of wood framing and asphalt shingles.

% by Weight White wood trim Interior trim Intact <0.0080% Tan gypsum board Interior walls Intact <0.0080% White exterior trim Exterior fascia fair 0.010% White concrete Exterior concrete sills fair <0.0080%

Based on the sample analysis, none of the coatings should be considered Lead Based Paint.

Building 400

Building 400 is an occupied office building. The existing exterior is brick and cmu cavity wall and the roof structure is steel framing with wood decking/

% by Weight White steel door frame Interior door frames intact <0.016% Cream gypsum board Interior gypsum board intact <0.0080% White exterior concrete Exterior base intact 0.065%

Building 431

Building 431 is an occupied storage building. The existing exterior is brick and cmu cavity wall and the roof structure is steel framing with wood decking/

% by Weight Cream brick Interior walls poor 0.052% Black concrete Interior walls base poor 0.099% White steel Interior steel structure intact 13% White gypsum board Interior walls intact <0.0080% Gray mechanical vent Roof vent fair 13% White concrete Interior structure intact 0.70%

Cream brick Black concrete White steel Gray mechanical vent White concrete

Building 1042

Building Description and Findings (Inspected 04-30-19)

Building 1042 is an operational barracks building. The building exterior is brick and cmu. Interior partitions are cmu and wood framed with gypsum board, and the roof is a built up roof system over a concrete deck.

% by Weight Cream CMU Exterior Intact <0.0080% Cream Gypsum Board Interior Intact <0.0080% White Concrete Ceiling Interior Intact <0.0080% Brown Metal Door System Exterior Intact 0.026% Red CMU Wall Interior Intact <0.0080% Red Metal Handrail Exterior Intact 0.031%

Based on the sample analysis, the following coatings should be considered Lead Based Paint.

Brown Metal Door System Red Metal Handrail

Building 1819

Building 1819 is a partially used storage building and office. The building is a pre-engineered metal building with metal wall and roof panels. The interior contains gypsum board/metal stud walls and no ceilings.

% by Weight White gypsum board Interior walls Intact <0.0098% White steel structure Interior steel Intact 1.3%

White Steel Structure

Building AS3906

Building Description and Findings (Inspected 11-04-21)

Building AS3906 is a maintenance building with cmu exterior walls, steel roof structure and a membrane roof over insulation.

% by Weight Cream cmu Exterior walls intact <0.0080% Gray steel doors doors intact <0.010%

Building AS4114

Building AS4114 is a storage building with cmu exterior walls, steel roof structure and a built-up roof over insulation.

% by Weight White CMU CMU walls intact 0.036% Red steel door Steel door intact 0.015% White steel structure Interior steel structure intact <0.0080%

White CMU Red steel door

Structure BB269

Building BB269 is a mechanical building. The existing exterior is cmu and the roof structure is concrete with a built-up roof.

Gray steel door Exterior door intact 0.039%

Gray steel door

Building FC260

Building Description and Findings (Inspected 03-28-18)

Building FC260 is a Communication Analysis Facility. The building exterior is brick with a built-up roof. The interior walls are cmu. Ceilings are plaster board in the bathroom areas as well as drop in acoustical ceiling tiles in other areas. (16) samples were taken for analysis.

Gray metal door system Interior Intact 0.0086% White interior CMU Interior Intact <0.0080% White interior steel column Interior Intact 0.45% Yellow concrete safety paint Exterior Intact 2.1% Yellow steel bollard Exterior Intact <0.0080% White steel tank Exterior Intact 0.087% Brown exterior metal door system Exterior Intact 0.014% Yellow exterior steel railing Exterior Intact 0.010%

Based on the sample analysis, the following coatings should be considered Lead Based Paint.

Gray metal door system White interior steel column Yellow concrete safety paint White steel tank Brown exterior metal door system Yellow exterior steel railing

Building H35

Building H35 is an abandoned well house. The existing exterior is brick and cmu cavity walls. The roof consists of wood framing and asphalt shingles.

% by Weight White wood Exterior wood poor 26% Cream metal door system Metal door system poor 9.6%

Building M203

Building Description and Findings (Inspected 10-27-21)

Building M203 is a storage building. The existing exterior is stucco and stud cavity walls with interior wood stud and gypsum walls. The roof consists of wood framing and asphalt shingles.

Cream stucco Exterior Intact 0.17% White wood frame Exterior frame poor 2.2% Cream cmu Interior walls poor 1.3% Black concrete base Interior wall base poor 1.4% White wood trim Interior wood trim Intact <0.022% Black gypsum board Interior walls at conference room Intact <0.080% Red wood column Interior columns fair 2.3% Cream gypsum board Interior walls at storage Intact <0.080% White steel door Exterior door fair 0.0082%

Cream Stucco White wood frame Cream CMU Black concrete base Red wood column White steel door

Building M441

Building Description and Findings (Inspected 03.23.18)

Building M441 is a mechanical building. The existing exterior brick and cmu with precast concrete panels above. The roof consists of steel framing, decking, insulation and a built-up roof system.

Brown Metal Door system CMU walls intact 0.28%

Brown Metal Door System

Building RR206

Building Description and Findings (Inspected 05.26.20)

Building RR206 is an operational training building. The existing exterior is stucco and stud cavity walls with interior wood stud and gypsum walls. The roof consists of wood framing and asphalt shingles.

% by Weight Exterior cream stucco Exterior walls intact <0.0080% Interior cream gypsum board Interior walls intact <0.0080% White wood door Interior door intact <0.0080% Gray steel door Exterior door intact 0.018% White brick Exterior brick trim intact 0.21%

Gray steel door White brick

Building RR207

Building Description and Findings (Inspected 04.29.19)

Building RR207 is an operational training building. The existing exterior is stucco and stud cavity walls with interior wood stud and gypsum walls. The roof consists of wood framing and asphalt shingles.

% by Weight Exterior cream stucco Exterior walls intact 0.029% White metal door system Exterior door intact <0.0080% Exterior white brick Exterior brick trim intact <0.0080% Cream gypsum board Interior walls intact <0.0080% Gray wood door frame Door frames intact <0.0080%

Cream exterior stucco

Structure SAS2849

Structure SAS2849 is a wood shelter with wood framing and asphalt shingles

Red wood structure Wood structure intact <0.012%

Structure SFC254

Building Description and Findings (Inspected 05.13.20)

Structure SFC254 is a vehicle maintenance ramp. The ramp is constructed of concrete and has galvanized safety rails.

Yellow concrete safety paint Concrete ramp intact <0.0080%

Structure SG401

Structure SG401 is a wood shelter with wood framing and asphalt shingles.

Red steel structure Exterior walls intact <0.011%

Structure SAS3601

Structure SAS3601 is an operable radar on the airfield.

% by Weight Red steel Steel exterior intact 1.7% White steel Steel exterior intact <0.011%

Red steel

Building TC1064

Building TC1064 is an occupied residential building. The existing exterior is cmu and stud cavity walls with interior wood stud and gypsum walls. The roof consists of wood framing and asphalt shingles.

% by Weight Cream cmu Exterior walls intact <0.015% Cream metal doors Exterior doors intact 0.013%

Cream metal doors

Building TC1065

Building TC1065 is an occupied residential building. The existing exterior is

% by Weight Cream cmu Exterior walls intact <0.0080% Cream metal doors Exterior doors intact <0.0080%

Building TC1066

Building TC1066 is an occupied residential building. The existing exterior is

% by Weight Cream cmu Exterior walls intact 0.093%

Cream CMU

Building TC1067

Building TC1067 is an occupied residential building. The existing exterior is

% by Weight Cream cmu Exterior walls intact <0.0080%

Building TC1068

Building TC1068 is an occupied residential building. The existing exterior is

% by Weight Cream cmu Exterior walls intact <0.0080%

Building TC1069

Building TC1069 is an occupied residential building. The existing exterior is

% by Weight Cream cmu Exterior walls intact 0.022%

Cream CMU

Recommendations

A. Any demolition/renovation work in which lead coated surfaces are disturbed must be in compliance with all Federal, State, and Local regulations. All work should be conducted by workers trained in "lead safe practices" as outlined by

OSHA.

B. If additional suspect materials are discovered during demolition/renovation, they should be classified presumed to contain lead-based paint until sampling by a state of North Carolina licensed Lead Inspector personnel and analysis by an Accredited and state of North Carolina licensed laboratory can be performed.

See attached for Plan Locations, Lead Laboratory Results, and Chain of Custody.

If further information is required, please contact me at 1-252-636-8778

Report Prepared by:

Christopher B. Walker North Carolina Lead Inspector Accreditation# 110239 The Walker Group Architecture, Inc.

PO Box 541 New Bern, NC 28560

ConcentrationAnalyzed Weight Reporting Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

0.62 % wt10/26/2021 .2636 g022107741-0001 0.080

Client Sample 33-pb-01

% wt

0.67 % wt10/26/2021 .2983 g022107741-0002 0.080

Client Sample 33-pb-02

% wt

0.16 % wt10/26/2021 .304 g022107741-0003 0.0080

Client Sample 33-pb-03

% wt

0.038 % wt10/26/2021 .2816 g022107741-0004 0.0080

Client Sample 33-pb-04

% wt

<0.0080 % wt10/26/2021 .29 g022107741-0005 0.0080

Client Sample 33-pb-05

% wt

<0.0085 % wt10/26/2021 .2352 g022107741-0006 0.0085

Client Sample 33-pb-06

% wt

0.043 % wt10/26/2021 .2926 g022107741-0007 0.0080

Client Sample 33-pb-07

% wt

0.57 % wt10/26/2021 .435 g022107741-0008 0.080

Client Sample 33-pb-08

% wt

0.55 % wt10/26/2021 .2647 g022107741-0009 0.080

Client Sample 33-pb-09

% wt

1.3 % wt10/26/2021 .3125 g022107741-0010 0.080

Client Sample 33-pb-10

% wt

<0.0080 % wt10/26/2021 .2695 g022107741-0011 0.0080

Client Sample 33-pb-11

% wt

Page 1 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05 http://www.EMSL.com mailto:greensborolab@emsl.com

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt10/26/2021 .2827 g022107741-0012 0.0080

Client Sample 33-pb-12

% wt

18 % wt10/26/2021 .2898 g022107741-0013 0.80

Client Sample 33-pb-13

% wt

22 % wt10/26/2021 .2943 g022107741-0014 0.80

Client Sample 33-pb-14

% wt

<0.0080 % wt10/26/2021 .2958 g022107741-0015 0.0080

Client Sample 33-pb-15

% wt

0.019 % wt10/26/2021 .2639 g022107741-0016 0.0080

Client Sample 33-pb-16

% wt

0.27 % wt10/26/2021 .2692 g022107741-0017 0.0080

Client Sample 33-pb-17

% wt

0.22 % wt10/26/2021 .2874 g022107741-0018 0.0080

Client Sample 33-pb-18

% wt

<0.0080 % wt10/26/2021 .2635 g022107741-0019 0.0080

Client Sample 1819-pb-01

% wt

<0.0080 % wt10/26/2021 .3181 g022107741-0020 0.0080

Client Sample 1819-pb-02

% wt

0.55 % wt10/26/2021 .3019 g022107741-0021 0.080

Client Sample 1819-pb-03

% wt

1.3 % wt10/26/2021 .3154 g022107741-0022 0.080

Client Sample 1819-pb-04

% wt

Page 2 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

0.13 % wt10/26/2021 .2689 g022107741-0023 0.0080

Client Sample 14-pb-01

% wt

0.067 % wt10/26/2021 .3098 g022107741-0024 0.0080

Client Sample 14-pb-02

% wt

<0.0080 % wt10/26/2021 .2716 g022107741-0025 0.0080

Client Sample 14-pb-03

% wt

<0.0080 % wt10/26/2021 .2964 g022107741-0026 0.0080

Client Sample 14-pb-04

% wt

<0.0080 % wt10/26/2021 .2615 g022107741-0027 0.0080

Client Sample 14-pb-05

% wt

<0.0080 % wt10/26/2021 .2803 g022107741-0028 0.0080

Client Sample 14-pb-06

% wt

0.018 % wt10/26/2021 .3226 g022107741-0029 0.0080

Client Sample 14-pb-07

% wt

0.014 % wt10/26/2021 .3082 g022107741-0030 0.0080

Client Sample 14-pb-08

% wt

0.0087 % wt10/26/2021 .3312 g022107741-0031 0.0080

Client Sample 14-pb-09

% wt

0.010 % wt10/26/2021 .2765 g022107741-0032 0.0080

Client Sample 14-pb-10

% wt

<0.0080 % wt10/26/2021 .2899 g022107741-0033 0.0080

Client Sample 14-pb-11

% wt

Page 3 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt10/26/2021 .3953 g022107741-0034 0.0080

Client Sample 14-pb-12

% wt

0.0080 % wt10/26/2021 .3465 g022107741-0035 0.0080

Client Sample 315-pb-01

% wt

0.013 % wt10/26/2021 .2889 g022107741-0036 0.0080

Client Sample 315-pb-02

% wt

<0.0080 % wt10/26/2021 .2609 g022107741-0037 0.0080

Client Sample 315-pb-03

% wt

<0.0080 % wt10/26/2021 .2641 g022107741-0038 0.0080

Client Sample 315-pb-04

% wt

0.21 % wt10/26/2021 .2751 g022107741-0039 0.0080

Client Sample 315-pb-05

% wt

0.22 % wt10/26/2021 .3038 g022107741-0040 0.0080

Client Sample 315-pb-06

% wt

<0.0080 % wt10/26/2021 .286 g022107741-0041 0.0080

Client Sample 315-pb-07

% wt

<0.0080 % wt10/26/2021 .4517 g022107741-0042 0.0080

Client Sample 315-pb-08

% wt

12 % wt10/26/2021 .3185 g022107741-0043 0.80

Client Sample 315-pb-09

% wt

13 % wt10/26/2021 .3498 g022107741-0044 0.80

Client Sample 315-pb-10

% wt

Page 4 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

0.051 % wt10/26/2021 .3081 g022107741-0045 0.0080

Client Sample 315-pb-11

% wt

0.039 % wt10/26/2021 .2674 g022107741-0046 0.0080

Client Sample 315-pb-12

% wt

<0.0080 % wt10/26/2021 .318 g022107741-0047 0.0080

Client Sample 315-pb-13

% wt

<0.0080 % wt10/26/2021 .3694 g022107741-0048 0.0080

Client Sample 315-pb-14

% wt

0.28 % wt10/26/2021 .311 g022107741-0049 0.0080

Client Sample 315-pb-15

% wt

0.26 % wt10/26/2021 .3296 g022107741-0050 0.0080

Client Sample 315-pb-16

% wt

4.2 % wt10/26/2021 .3744 g022107741-0051 0.80

Client Sample H35-pb-01

% wt

26 % wt10/26/2021 .2639 g022107741-0052 0.80

Client Sample H35-pb-02

% wt

9.4 % wt10/26/2021 .2767 g022107741-0053 0.80

Client Sample H35-pb-03

% wt

9.6 % wt10/26/2021 .3362 g022107741-0054 0.80

Client Sample H35-pb-04

% wt

<0.0080 % wt10/26/2021 .2878 g022107741-0055 0.0080

Client Sample 344-pb-01

% wt

Page 5 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt10/26/2021 .2957 g022107741-0056 0.0080

Client Sample 344-pb-02

% wt

<0.0080 % wt10/26/2021 .2869 g022107741-0057 0.0080

Client Sample 344-pb-03

% wt

<0.0080 % wt10/26/2021 .2816 g022107741-0058 0.0080

Client Sample 344-pb-04

% wt

0.010 % wt10/26/2021 .2899 g022107741-0059 0.0080

Client Sample 344-pb-05

% wt

0.0095 % wt10/26/2021 .2778 g022107741-0060 0.0080

Client Sample 344-pb-06

% wt

<0.0080 % wt10/26/2021 .2732 g022107741-0061 0.0080

Client Sample 344-pb-07

% wt

<0.0080 % wt10/26/2021 .262 g022107741-0062 0.0080

Client Sample 344-pb-08

% wt

0.016 % wt10/26/2021 .2777 g022107741-0063 0.0080

Client Sample 334-pb-01

% wt

0.017 % wt10/26/2021 .3227 g022107741-0064 0.0080

Client Sample 334-pb-02

% wt

3.7 % wt10/26/2021 .275 g022107741-0065 0.080

Client Sample 334-pb-03

% wt

3.2 % wt10/26/2021 .2823 g022107741-0066 0.080

Client Sample 334-pb-04

% wt

Page 6 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

9.0 % wt10/26/2021 .3275 g022107741-0067 0.80

Client Sample 334-pb-05

% wt

7.0 % wt10/26/2021 .3009 g022107741-0068 0.80

Client Sample 334-pb-06

% wt

<0.0080 % wt10/26/2021 .2533 g022107741-0069 0.0080

Client Sample 334-pb-07

% wt

0.062 % wt10/26/2021 .288 g022107741-0070 0.0080

Client Sample 334-pb-08

% wt

<0.0080 % wt10/26/2021 .2878 g022107741-0071 0.0080

Client Sample 334-pb-09

% wt

<0.0080 % wt10/26/2021 .274 g022107741-0072 0.0080

Client Sample 334-pb-10

% wt

<0.0080 % wt10/26/2021 .3133 g022107741-0073 0.0080

Client Sample 334-pb-11

% wt

<0.0080 % wt10/26/2021 .2515 g022107741-0074 0.0080

Client Sample 334-pb-12

% wt

<0.028 % wt10/26/2021 .0726 g022107741-0075 0.028

Client Sample 334-pb-13

% wt

<0.047 % wt10/26/2021 .0427 g022107741-0076 0.047

Client Sample 334-pb-14

% wt

<0.011 % wt10/26/2021 .1852 g022107741-0077 0.011

Client Sample 334-pb-15

% wt

Page 7 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0083 % wt10/26/2021 .242 g022107741-0078 0.0083

Client Sample 334-pb-16

% wt

0.077 % wt10/26/2021 .265 g022107741-0079 0.0080

Client Sample 334-pb-17

% wt

0.034 % wt10/26/2021 .1262 g022107741-0080 0.016

Client Sample 334-pb-18

% wt

0.17 % wt10/26/2021 .1897 g022107741-0081 0.011

Client Sample 334-pb-19

% wt

0.030 % wt10/26/2021 .1574 g022107741-0082 0.013

Client Sample 334-pb-20

% wt

<0.0080 % wt10/26/2021 .2539 g022107741-0083 0.0080

Client Sample 334-pb-21

% wt

<0.0080 % wt10/26/2021 .2589 g022107741-0084 0.0080

Client Sample 334-pb-22

% wt

0.041 % wt10/26/2021 .2514 g022107741-0085 0.0080

Client Sample H35-pb-05

% wt

0.018 % wt10/26/2021 .3259 g022107741-0086 0.0080

Client Sample H35-pb-06

% wt

Page 8 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 10/21/2021 11:30 AM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022107741 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

Guidelines for Federal USEPA/HUD Lead in Paint Chips =0.5 % Wt or =1.0 mg/cm² is the EPA definition of a lead-based paint.

Above EPA definition of a lead-based paintAbove RL but below EPA definition of a lead-based paint

Below Method Reporting Limit (RL)

These guidance limits are typically used in most scenarios. More stringent local or project specific guidelines may apply.

Please contact the laboratory for statement of uncertainty data for the utility of properly evaluating these results against any regulatory standards or guidelines.

No responsibility or liability is assumed for the manner in which the results are used or interpreted.

Page 9 of 9Test Report PB w/RD/I-7.32.3 Printed: 10/27/2021 7:50:05 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 10/27/2021 07:50:05

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 11/2/2021 02:34 PM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

10/27/2021Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022108027 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt11/5/2021 .2571 g022108027-0001 0.0080

Client Sample 10/27/2021

TC1064-Pb-01

% wt

<0.015 % wt11/5/2021 .1325 g022108027-0002 0.015

Client Sample 10/27/2021

TC1064-Pb-02

% wt

0.013 % wt11/5/2021 .2814 g022108027-0003 0.0080

Client Sample 10/27/2021

TC1064-Pb-03

% wt

<0.0080 % wt11/5/2021 .288 g022108027-0004 0.0080

Client Sample 10/27/2021

TC1064-Pb-04

% wt

<0.0080 % wt11/5/2021 .2658 g022108027-0005 0.0080

Client Sample 10/27/2021

TC1064-Pb-05

% wt

<0.0080 % wt11/5/2021 .2628 g022108027-0006 0.0080

Client Sample 10/27/2021

TC1064-Pb-06

% wt

<0.0080 % wt11/5/2021 .2995 g022108027-0007 0.0080

Client Sample 10/27/2021

TC1065-Pb-01

% wt

<0.0080 % wt11/5/2021 .2631 g022108027-0008 0.0080

Client Sample 10/27/2021

TC1065-Pb-02

% wt

<0.0081 % wt11/5/2021 .2457 g022108027-0009 0.0081

Client Sample 10/27/2021

TC1065-Pb-03

% wt

<0.0080 % wt11/5/2021 .2648 g022108027-0010 0.0080

Client Sample 10/27/2021

TC1065-Pb-04

% wt

<0.0080 % wt11/5/2021 .2723 g022108027-0011 0.0080

Client Sample 10/27/2021

TC1065-Pb-05

% wt

Page 1 of 6Test Report PB w/RD/I-7.32.3 Printed: 11/8/2021 8:13:22 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 11/08/2021 08:13:22

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 11/2/2021 02:34 PM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

10/27/2021Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022108027 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt11/5/2021 .2653 g022108027-0012 0.0080

Client Sample 10/27/2021

TC1065-Pb-06

% wt

0.014 % wt11/5/2021 .3222 g022108027-0013 0.0080

Client Sample 10/27/2021

TC1066-Pb-01

% wt

0.093 % wt11/5/2021 .3136 g022108027-0014 0.0080

Client Sample 10/27/2021

TC1066-Pb-02

% wt

<0.0080 % wt11/5/2021 .2844 g022108027-0015 0.0080

Client Sample 10/27/2021

TC1066-Pb-03

% wt

<0.0080 % wt11/5/2021 .3383 g022108027-0016 0.0080

Client Sample 10/27/2021

TC1066-Pb-04

% wt

<0.0091 % wt11/5/2021 .2204 g022108027-0017 0.0091

Client Sample 10/27/2021

TC1066-Pb-05

% wt

<0.018 % wt11/5/2021 .1092 g022108027-0018 0.018

Client Sample 10/27/2021

TC1066-Pb-06

% wt

<0.0080 % wt11/5/2021 .2697 g022108027-0019 0.0080

Client Sample 10/27/2021

TC1067-Pb-01

% wt

<0.0080 % wt11/5/2021 .3027 g022108027-0020 0.0080

Client Sample 10/27/2021

TC1067-Pb-02

% wt

<0.0080 % wt11/5/2021 .3026 g022108027-0021 0.0080

Client Sample 10/27/2021

TC1067-Pb-03

% wt

<0.0080 % wt11/5/2021 .2809 g022108027-0022 0.0080

Client Sample 10/27/2021

TC1067-Pb-04

% wt

Page 2 of 6Test Report PB w/RD/I-7.32.3 Printed: 11/8/2021 8:13:22 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 11/08/2021 08:13:22

Detection LimitLab ID: LeadCollected

Attn: Chris Walker The Walker Group Architecture PO Box 541 New Bern, NC 28563

Received: 11/2/2021 02:34 PM

IR Demo Package F

Fax: (252) 636-8992 Phone: (252) 636-8778

Project:

10/27/2021Collected:

Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*

EMSL Analytical, Inc.

706 Gralin Street, Kernersville, NC 27284 Phone/Fax: (336) 992-1025 / (336) 992-4175 http://www.EMSL.com greensborolab@emsl.com

022108027 CustomerID: WALK85 CustomerPO:

ProjectID:

EMSL Order:

<0.0080 % wt11/5/2021 .2508 g022108027-0023 0.0080

Client Sample 10/27/2021

TC1067-Pb-05

% wt

<0.0084 % wt11/5/2021 .2379 g022108027-0024 0.0084

Client Sample 10/27/2021

TC1067-Pb-06

% wt

<0.0080 % wt11/5/2021 .3474 g022108027-0025 0.0080

Client Sample 10/27/2021

TC1068-Pb-01

% wt

<0.0080 % wt11/5/2021 .3451 g022108027-0026 0.0080

Client Sample 10/27/2021

TC1068-Pb-02

% wt

<0.0080 % wt11/5/2021 .3076 g022108027-0027 0.0080

Client Sample 10/27/2021

TC1068-Pb-03

% wt

<0.0080 % wt11/5/2021 .2982 g022108027-0028 0.0080

Client Sample 10/27/2021

TC1068-Pb-04

% wt

<0.0080 % wt11/5/2021 .2638 g022108027-0029 0.0080

Client Sample 10/27/2021

TC1068-Pb-05

% wt

<0.0080 % wt11/5/2021 .2804 g022108027-0030 0.0080

Client Sample 10/27/2021

TC1068-Pb-06

% wt

<0.0080 % wt11/5/2021 .2868 g022108027-0031 0.0080

Client Sample 10/27/2021

TC1069-Pb-01

% wt

0.022 % wt11/5/2021 .2704 g022108027-0032 0.0080

Client Sample 10/27/2021

TC1069-Pb-02

% wt

<0.0080 % wt11/5/2021 .3413 g022108027-0033 0.0080

Client Sample 10/27/2021

TC1069-Pb-03

% wt

Page 3 of 6Test Report PB w/RD/I-7.32.3 Printed: 11/8/2021 8:13:22 AM

James Cole, Laboratory Manager or other approved signatory

EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.

Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.

Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.

Samples analyzed by EMSL Analytical, Inc. Kernersville, NC EMSL Lab ID 102564 is accredited by the AIHA Laboratory Accreditation Program (AIHA-LAP), LLC in the Environmental Lead accreditation program for Lead in Paint Chips.

Initial report from 11/08/2021 08:13:22

Detection LimitLab ID: LeadCollected

Attn: Chris Walker…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .